Tender For Repair/Maintenance To Certain Lt Equipment Alongwith Electrical Fittings And Repair To Certain B/R Works At Af Station Naraina And Afnd In Aor Of Ge (Af) Faridabad, FARIDAbad-Haryana

Military Engineer Services-MES has published Tender For Repair/Maintenance To Certain Lt Equipment Alongwith Electrical Fittings And Repair To Certain B/R Works At Af Station Naraina And Afnd In Aor Of Ge (Af) Faridabad. Submission Date for this Tender is 03-01-2023. Rough Finishing Tools Tenders in FARIDAbad Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

35258374
Corrigendum : Tender For Repair/Maintenance To Certain Lt Equipment Alongwith Electrical Fittings And Repair To Certain B/R Works At Af Station Naraina And Afnd In Aor Of Ge (Af) Faridabad
Open Tender
Indian
Haryana
FARIDAbad
03-01-2023

Tender Details

Tender For Repair / Maintenance To Certain Lt Equipment Alongwith Electrical Fittings And Repair To Certain B / R Works At Af Station Naraina And Afnd In Aor Of Ge ( Af ) Faridabad - Taking Down Carefully Copper / Aluminium Point Wiring ( Light, Fan, Socket, Bell Or Power ) Completeincluding All Electrical Fittings & Fixtures ( Dbs, Submain, Cables Etc ) And Making Good Disturbed Surfaces Of Wall , Floor Etc And Matching Wth Original Colour Of Wall, Complete All As Specified And Directed By Engineer-In-Charge. 2 M&L For Point Wiring Light Point / Bell Point With Single Core Pvc Insulated Unsheathed 1100 Volt Grade Cable With Stranded Copper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) Drawn Through In Existing Concealed Conduit, Fixed On Wall, Ceiling With Gi Saddles Gi Screws, Rawal Plugs ( Concealed Conduit Wiring ) With All Fittings Including Tee, Junction Boxes And Provision Of Modular Metal Flush Boxof Suitable Sizemodular White Cover Plate With Frame For Mounting Switch Sockets And Regulators And Drawing Continuous Earth Wire With And Including Pvc Insulated Unsheathed 1100 Volts Grade Cable With Stranded Coper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) Complete All As Specified And Directed By Engineer-In-Charge For Following :-.Note:-After Rewiring Cutting Chasing Portion Should Be Matched With Existing Finishes Of Walls. 3 All As Per Item No 2 Above But 5 Amp Socket Outlet, Independent Complete All As Specified And Directed By Engineer-In-Charge. 4 All As Per Item No 2 Above But On The Same Board Complete All As Specified And Directed By Engineer-In-Charge. 5 All As Per Item No 2 Above But 2.5 Sq Mm Wire For One 15 Amps Socket Outlet Independent With Continuous Pvc Insulated Single Core Green Colour Copper Earth Wire Of Size 1.5 Sq Mm Connected To Common Earth Dolly Complete All As Specified And Directed By Engineer-In-Charge. 6 M&L Switch Flush Type Bell Push 1 Module Modular Typebutton 6 Amp After Dismantling Old One Complete All As Specified And Directed By Engineer-In-Charge. 7 M&L For Socket Outlet 6A-2 / 3 Pin Combined 2 Module Modular Type Complete All As Specified And Directed By Engineer-In-Charge. 8 M&L For Socket Outlet 6A / 16A-2 / 3 Pin Combined 2 Module Modular Type Complete All As Specified And Directed By Engineer-In-Charge. 9 M&L For Switch 6 Amps Modular Type One One Way Complete All As Specified And Directed By Engineer-In-Charge. 10 M&L For Switch 16 Amps Modular Type One One Way Complete All As Specified And Directed By Engineer-In-Charge. 11 M&L For Modular Type Fan Regulator ( Step Type ) , 120 W-1 Module Complete All As Specified And Directed By Engineer-In-Charge. 12 M&L Metal Flush Box 3 Module Complete All As Specified And Directed By Engineer-In-Charge. 13 M&L Metal Flush Box 6 Module Complete All As Specified And Directed By Engineer-In-Charge. 14 M&L Metal Flush Box 12 Module Complete All As Specified And Directed By Engineer-In-Charge. 15 M&L For White Cover Plate With Frame, 12 Module Complete All As Specified And Directed By Engineer-In-Charge. 16 M&L For White Cover Plate With Frame, 6 Module Complete All As Specified And Directed By Engineer-In-Charge. 17 M&L For White Cover Plate With Frame, 3 Module Complete All As Specified And Directed By Engineer-In-Charge. 18 S&F Bell Ding Dong Ac 230Volts Single Pole Complete All As Specified And Directed By Engineer-In-Charge. 19 S &F In Replacement Switch Socket Combination 16A, 6Pin, 3Module 220 / 230 Volts Complete All As Specified And Directed By Engineer-In-Charge. 20 S&F In Replacement Switch Piano Type 5 Amp Sp One Way Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 21 S&Fin Replacement Switch 15 Amps Sp One Way Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 22 S&F In Replacement Socket Outlet 3 Pin 5 Amps Flush Type Complete All As Specified And Directed By Engineer-In-Charge. 23 S&F In Replacement Socket Outlet 2-In-1, 3 Pin 5 Amp And 15 Amps Complete All As Specified And Directed By Engineer-In-Charge. 24 M&L For Bell Push Flush Type 5 / 6 Amps One Way Complete All As Specified And Directed By Engineer-In-Charge. 25 S&F In Replacement Of Wall Mounting Slim 18 / 20 Watt 4 Feet Led Batten Luminaire , White With Engineering Plastic Batten With White Acrylic Cover Sleek Design & High Efficiency For Wall And Surface Mounted Applicationsall As Specified And Directed By Engineer-In-Charge. 26 S&F In Replacement Of Wall Mountingled Slim 9 / 10 Watt 2 Feet, White With High Efficient Leds & Glare Free Opal Diffuser Complete All As Specified And Directed By Engineer-In-Charge. 27 S & F In Replacement Enviroment Friendly Recess / Surface Mounting Led Flat Panel 2X2, Cool White With High Efficient Leds & Glare Free Opal Diffuser ( 36 W ) Pf>0.95 Driver Life >25000 Hours, Operating Range 140V To 280 V Includingall Accessaries Complete All As Specified And Directed By Engineer-In-Charge. 28 S& F Led Fitting Bulkhead 10 Watt Single Phase 50 Hz Ip 66 Outdoor Type Complete All As Specified And Directed By Engineer-In-Charge. 29 S&F In Replacement Of Recesses Mountingled Slim Round Downlighter 12 Watt Warmwhite With High Efficient Leds & Glare Free Opal Diffuser Complete All As Specified And Directed By Engineer-In-Charge. 30 S&F In Replacement Of Recesses Mountingled Slim Square Downlighter 12 Watt Warmwhite With High Efficient Leds & Glare Free Opal Diffuser Complete All As Specified And Directed By Engineer-In-Charge. 31 S&F In Replacement Mcb Sp 5 To 32 Amps, 240 Volts Curve C, Breaking Capacity 10Kacomplete All As Specified And Directed By Engineer-In-Charge. 32 S&F In Replacement Mcb Spn32 To 63 Amps, 240 Volts, Curve C, Breaking Capacity 10 Ka, Complete All As Specified And Directed By Engineer-In-Charge. 33 S&F In Replacement Mcb Tp 40 To 63 Amps, 415 Volts Curve C, Breaking Capacity 10Kacomplete All As Specified And Directed By Engineer-In-Charge. 34 S&F In Replacement Mcb Tpn 40 Amps, 415 Volts Curve C, Breaking Capacity 10Ka, Complete All As Specified And Directed By Engineer-In-Charge. 35 S&F In Replacement Mcb Tpn 63 Amps, 415 Volts Curve C, Breaking Capacity 10Ka, Complete All As Specified And Directed By Engineer-In-Charge. 36 S&F In Replacement Mcb 4 Pole 100 Amps, 415 Volts Curve C, Breaking Capacity 10Ka, Complete All As Specified And Directed By Engineer-In-Charge. 37 S&F In Replacement Mccb, Four Pole, 415 Volts, 125 Amps , Curve C, Breaking Capacity 10 Ka, Complete All As Specified And Directed By Engineer-In-Charge. 38 S&F Sheet Metal Enclosuresdbdouble Door Verticle Distribution Type, 04 Way, Tpn Db , Ip43, 415V & Suitable For Mccb Tp As Incomming Including Shruded Neutral Bar & Pan Assy With Earthing Terminal As Provided By Manufacturercomplete All As Specified And Directed By Engineer-In-Charge. 39 S&F Sheet Metal Enclosuresdbdouble Doordistribution Type, 04 Way, Tpn Db , Ip43, 415V & Suitable For Mcb Tp As Incomming Including Shruded Neutral Bar & Pan Assy With Earthing Terminal As Provided By Manufacturer Complete All As Specified And Directed By Engineer-In-Charge. 40 S&F Sheet Metal Enclosuresdbdouble Doordistribution Type, 06 Way, Tpn Db , Ip43, 415V & Suitable For Mcb Tp As Incomming Including Shruded Neutral Bar & Pan Assy With Earthing Terminal As Provided By Manufacturer Complete All As Specified And Directed By Engineer-In-Charge. 41 S&F In Replacement Sheet Metal Enclosuresdbdouble Door Type 8 Way Spn 240 Voltincluding 200 Amps Rated Bus Bar With Neutral Link Complete All As Specified And Directed By Engineer-In-Charge. 42 S&F In Replacement Sheet Metal Enclosuresdbdouble Door Type 4 Way Spn 240 Voltincluding 200 Amps Rated Bus Bar With Neutral Link Complete All As Specified And Directed By Engineer-In-Charge. 43 S&F For Ceiling Rose Surface Bakelite 65X50mm Two To Three Terminals Complete All As Specified And As Directed By Engr-In-Charge. 44 S& F In Repair Casing Capping Of Size 15 Mmto Cover The Copper Conductor In Wall Complete All As Specified And Directed By Engineer-In-Charge. 45 S&F In Replacement Of Led Electronic Driver Suitable For 20 Watt Led Batten Fitting Complete All As Specified And Directed By Engineer-In-Charge. 46 S&F In Replacement Of Led Electronic Driver Suitable For 36 Watt Led ( 2X2 ) Recesses Mountedfitting Complete All As Specified And Directed By Engineer-In-Charge. 47 Supply And Fix External Wall Mounted Switch Board 15 Amps Consisting Of One Number 15 Amps Switch And Socket Including Frame And Sheet Complete With Screws Al As Specified And As Directed By Engineer-In-Charge. 48 Supply And Fix External Wall Mounted Switch Board 5 Amps Consisting Of One Number 5 Amps Switch And Socket Including Frame And Sheet Complete With Screws Al As Specified And As Directed By Engineer-In-Charge. 49 Taking Down Pressure Pump Motor Of Capacity Upto 1 Hp, Single Phase , 230 Volt All As Per Specified And As Directed By Engineer-In-Charge. 50 M&L For Rewinding Of Presume Pump Motor Of Capacity Upto 1 Hp Single Phase , 230 Volt All As Per Specified And As Directed By Engineer-In-Charge. 51 M&L For Refixing Presume Pump Motor Of Capacity Upto 1 Hp Single Phase , 230 Volt All As Per Specified And As Directed By Engineer-In-Charge. 52 M&L Earthing Complete With Galvanized Steel Earth Plate Electrode 600X600x6.3 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Normal Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level, The Earth Electrode Surrounded By Adequate Quantity Of Charcoal Dust And Salt To A Packed Thickness Of 15Cm On All Side And Including Connected Toand Includinggalvanized Earth Lead Wire 4.0 Mm Dia Upto 7.5 Mtrs Long By Means Ofnuts And Bolts, Check Nuts And Washers Of Gi And Connected To Earhing Test Point And Earth Dollyall As Shown In Electrical Plate No 3 Of Mes Ssr Part I And Testing On Completion Includingnecessary Excavation And Earth Work In Any Type Of Soil, Pcc ( 1:3:6 ) Type C1 Chamber, Pre-Cast Rcc Slab 50Mm Thic In Cement Concrete ( 1:2:4 ) , Type B1, Reinforced With Welded Steel Wire Fabric Or Xpm, ( Weight Not Less Than 4 Kg Per Sqm ) With Cast Iron Frame, Funnel With Watering Pipe 20Mm Dia Medium Grade, Wire Mesh And Lugs, Gi Protection Pipe, 15Mm Dia, Light Grade, 7.5 Mtr Long For Protection Of Earth Lead Upto Test Point Etc Complete All As Specified And Directed By Engineer-In-Charge. 53 S&F Isi Marked Self Adhesive Pvc Electrical Insulation Tape Roll Of 25 Mm Wide, 0.125 Mm Thick And 25 Rm Lengthcomplete All As Specified And Directed By Engineer-In-Charge. 54 Taking Down Carefully Water Heater Storage Type 25 Ltrs / 50 Ltrs Capacity For Repair And Over Hauling And Opening To Geysers And Comprising Of Heating Element Thermo Stat Switch, Electric Connection Cleaning And Descaling With Descaling Solution The Geysers Tank And Checking Of Leakage On Pressure At 150 Psi And Testing For Smooth Functioning Complete All As Specified And Directed By Engineer-In-Charge. 55 S&F In Replacement Of Heating Element 2.00 Kw Capacity 230 Volt Suitable For Geysers Any Type As Per Site Requirement Isi Mark Complete All As Specified And Directed By Engineer-In-Charge:- 56 All As Per Item No 55Above But 1.5 Kw Capacity 230 Volt Complete All As Specified And Directed By Engineer-In-Charge. 57 S&F In Replacement Thermostat Switch Connection Any Type Suitable For Geyser Of Any Size / Model Complete All As Specified And Directed By Engineer-In-Charge. 58 S&F In Replacement Of Geyser Assembly Any Make Any Type For 25 Ltrs / 50 Ltrs Capacity Water Heater Including Replacement Of Rubber Seal Complete All As Specified And Directed By Engineer-In-Charge. 59 Supply And Fixing In Replacement Of Indicator Lamp ( Pilot Type ) For 25 Ltrs Water Heater Complete All As Specified And Directed By Engineer-In-Charge. 60 Supply And Fixing In Replacement Of Pvc Insulated Copper Conductor Cable 4 Sqmm Size 3 Core Grade ( For Geyser ) Complete All As Specified And Directed By Engineer-In-Charge. 61 S&F In Replacement Of Water Storage Tank Of Suitable For 25Ltrs Capacity Incl Glass Wool Complete All As Specified And Directed By Engineer-In-Charge. 62 S&F In Replacement Of Water Storage Tank Of Suitable For 50Ltrs Capacity Incl Glass Wool Complete All As Specified And Directed By Engineer-In-Charge. 63 Supply & Fixing In Replacement Ofbottom Cover Suitable Cylindrical Type Geyser For 25 Ltrs / 50 Ltrscapacity Geyser All As Specified And Directed By Engineer-In-Charge 64 All As Per Item No 63 Above But Of Capacity 50 Ltrscomplete All As Specified And Directed By Engineer-In-Charge. 65 M&L For Preparation Of External Surface Of Geyser Body 25 / 50 Ltrs Rubbing The Rusted Surface And Painting With Two Coats Of Spray Paint With Synthetic Enamel Paint Over A Coat Of Metal Primer Matching With Existing Colour Complete All As Specified And Directed By Engineer-In-Charge. 66 S& F Heavy Duty Pvc Pipe Suitable For Hot Water Flow For Geysers Of Capcity 25 To 50 Ltrs All As Specified And As Directed By Engineer-In-Charge 67 S& F Plug Top 3 Pin , 15 Amps Rating All As Specified And As Directed By Engineer-In-Charge 68 S& F Plug Top 3 Pin , 5 Amps Rating All As Specified And As Directed By Engineer-In-Charge 69 S&F In Replacement Ac Box With Plug And Socket Complete With 16 To 32 Amp Sp Mcb C Curve 10 Ka Complete All As Specified And Directed By Engineer-In-Charge. 70 S& F Water Heater Body Metallic Type Suitable For 25 Ltr Capacity Including Glass Wool For Insulation Top And Bottom Plates Complete All As Specified And Directed By Engineer-In-Charge. 71 S&F Heating Element 2-3 Kw Thread Type / Cone Type Compatible With 10 To 300 Ltr Solar Water Heater Tank Complete All As Specified And Directed By Engineer-In-Charge. 72 Supply And In Install Heating Element 2-3 Kw Thread Type / Cone Type Compatible With Instant Water Heater Complete All As Specified And Directed By Engineer-In-Charge. 73 S&F In Repair Wall Mounted Tpn Busbar Chamber Factory Made With Busbar Of Current Rating 400 Amp, 415 Volts Complete All As Specified And Directed By Engineer-In-Charge. 74 Supply And Fixing In Replacement Of Capacitor Of Following Sizes Complete All As Specified And Directed By Engineer-In-Charge. ( A ) .2.5 Mfd. 75 All As Per Item No 74 Above But 3.15 Mfd Complete All As Specified And Directed By Engineer-In-Charge. 76 M&L For Rewinding Of Burnt Fan1200 Mm / 1400 Mm Sweepwith Super Enameled Copper Wire Winding, Rubber Real, U’ Clamps, Nuts, Bolts, Washers And Split Pins Of Suitable Size As Per Details Of Any Make / Model Complete All As Specified And Directed By Engineer-In-Charge. 77 Taking Down Ceiling Fan 1200 Mm / 1400 Mm Sweep Removing Cleaning Of Dust, Properly Cleaning And Greasing Of Bearing And Connecting Up Complete All As Specified And Directed By Engineer-In-Charge. 78 Supply In Replacement For Rewinding Of Exhaust Fan As Per Details Given Below With Supper Enameled Copper Wireof Suitable Size Of Any Make / Type / Model Including Transportation Complete All As Specified And Directed By Engineer-In-Charge :- ( A ) Exhaust Fan 300Mm ( 12’Size ) 79 All As Per Item No 78 Abive Butexhaust Fan 380Mm ( 15” Size ) Complete All As Specified And Directed By Engineer-In-Charge. 80 Supply In Replacementfor Exhaust Fan Louver Of Following Size Complete All As Specified And Directed By Engineer-In-Charge. ( A ) 380 Mm 81 All As Per Item No 80 Above But 300 Mm Complete All As Specified And Directed By Engineer-In-Charge. 82 Taking Down Carefully Defective Wall Mounted Fan Of Any Size And Make And Oiling Greasing After Opening And Refixing The Fan To Its Position After Repair And Testing Complete All As Specified And Directed By Engineer-In-Charge. ( A ) Wall Fan Of Size 400Mm 83 All As Per Item No 82 Above But Wall Fan Of Size 300Mm Complete All As Specified And Directed By Engineer-In-Charge. 84 M&L For Rewinding Of Wall Mounted Fan Given Below With Super Enameled Copper Wire Including Of Suitable Of Size Of Any Make / Type Model Complete All As Specified And Directed By Engineer –In-Charge :- ( A ) Wall Fan Of Size 400Mm 85 All As Per Item No 84 Above But Wall Fan Of Size 300Mm Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacementventilation Fan Plastic 250 Mm Sweepbody 240 V 50 Hz Single Phase All As Specified And Directed By Engineer-In-Charge. 87 Supply And Fixing In Replacementventilation Fan Plastic 300 Mm Sweepbody 240 V 50 Hz Single Phase All As Specified And Directed By Engineer-In-Charge. 88 Supply And Fixing In Replacement 450Mm Sweep Wall Mounted Fan Plastic Body 240 V Single Phase 50 Hz All As Specified And Directed By Engineer-In-Charge. 89 S&F In Replacement For Wall Mounted Fan Bushes , Shaft And Suitable Body Cover , Moving Partcomplete All As Specified And Directed By Engineer-In-Charge. 90 Supply Only Isi Marked Self Adhesive Pvc Electrical Insulation Tape Roll Of 25 Mm Wide, 0.125 Mm Thick And 25 Rm Lengthcomplete All As Specified And Directed By Engineer-In-Charge. 91 S&F Decorative 45 W Led Strip Light Including Drivers And Necessary Connections Non-Integral Flexible Type With High Brihtness For Indoor And Outdoor Applications. Strip Can Be Cut At Marked Interval To Suit Desired Length.All As Specified And As Directed By Engineer-In-Charge 92 M&L Submain Wiring With 2 Runs Of Copper Conductor Frls Pvc Insulated Unsheathed Cable 1100 Volt Grade 4 Sqmm Drawn Through Pvc Conduit Medium Grade Isi Marked25mm Dia As Per Is Specification Fixed Concealedin Wall / Ceiling Including Conduit And Conduit Accessories And Incl Provn Of Pvc Insulated 2.5 Sqmm Multistranded Copper Conductor As Earth Continuity Conductor Connected To Earth Dolly All As Specified Including Dismantling Old And Making Good To The Disturbed Surface By Plastering And Two Coat Of Distamper Complete All As Specified And Directed By Engineer-In-Charge. Note : Two Runs Of 4 Sqmm Cable Alongwith One Run Of 2.5 Sqmm Pvc Insulated Unsheathedcopper Conductor As Earth Wire, Conduitand Conduit Accessories Will Be Measured As One Length ) 93 M&L Submain Wiring With 2 Runs Of Copper Conductor Frls Pvc Insulated Unsheathed Cable 1100 Volt Grade 6 Sqmm Drawn Through Pvc Conduit Medium Grade Isi Marked25mm Dia As Per Is Specification Fixed Concealedin Wall / Ceiling Including Conduit And Conduit Accessories And Incl Provn Of Pvc Insulated 4 Sqmm Multistranded Copper Conductor As Earth Continuity Conductor Connected To Earth Dolly All As Specified Including Dismantling Old And Making Good To The Disturbed Surface By Plastering And Two Coat Of Distamper Complete All As Specified And Directed By Engineer-In-Charge.Note : Two Runs Of 6 Sqmm Cable Alongwith One Run Of 4 Sqmm Pvc Insulated Unsheathedcopper Conductor As Earth Wire, Conduitand Conduit Accessories Will Be Measured As One Length ) . 94 S&F In Repair Led 40 Wattpost Top Lantern With Die Cast Aluminum Spigot , Spun Aluminium Caoted Top Cover Heat Sink , Opal Diffuser And Clear Acrylic Ip65 Complete All As Specified And Directed By Engineer-In-Charge. 95 S&F In Repair Led 60 Wattpost Top Lantern With Die Cast Aluminum Spigot , Spun Aluminium Caoted Top Cover Heat Sink , Opal Diffuser And Clear Acrylic Ip65 Complete All As Specified And Directed By Engineer-In-Charge. 96 S&F In Replacement Ofsingle Core Frls Cable Pvcunsheathed With Copper Conductor Of Size 1.5 Sqmmand Drawing Into Existing Conduit Complete All As Specified And Directed By Engineer-In-Charge. 97 S&F In Replacement Ofsingle Core Frls Cable Pvcunsheathed With Copper Conductor Of Size 2.5 Sqmmand Drawing Into Existing Conduit Complete All As Specified And Directed By Engineer-In-Charge. 98 Excavation In Trenches Not Exceeding 1.5 M Wide And And Not Exceeding 1.5 M Depth In Loose / Soft Soil And Getting Out Complete All As Specified And Directed By Engineer-In-Charge. 99 Returning, Filling In, With Excavated Soil Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm, Complete All As Specified And Directed By Engineer-In-Charge. 100 Removal Of Surplus Soil To Distance Not Exceeding 50 M And Depositing Where Directed At A Level Not Exceeding 1.5 M Above The Starting Point, Complete All As Specified And Directed By Engineer-In-Charge. 101 M & Lfor Brick Protection With Sub Class B Brickslaid Dry Flat Over Electric Cable In Trenches Complete All As Specified And Directed By Engineer-In-Charge. 102 M & Labour For Sand Cushioning With A Layer Of Sand 80Mm Thickconsolidated Before Laying Of Cable And 150Mm Thickconsolidated After Laying Of Cable In Trenches Ducts For Electric Cable Protection Including Consolidation Complete All As Specified And Directed By Engineer-In-Charge. 103 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 400 Sq Mm 3.5 Core Complete All As Specified And Directed By Engineer-In-Charge. 104 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 630 Sq Mm X 3.5 Core Complete All As Specified And Directed By Engineer-In-Charge. 105 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 50 Sq Mm 3.5 Core Complete All As Specified And Directed By Engineer-In-Charge. 106 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 25 Sq Mm 4 Core Complete All As Specified And Directed By Engineer-In-Charge. 107 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 10 Sq Mm 4 Core Complete All As Specified And Directed By Engineer-In-Charge. 108 Supply And Fix In Replacement Mccb 630 Amps , 4 Pole , 50 Ka , 50 Hz , 415 Voltincluding Under Voltage / Over Voltage Relay, Adjustable Overload Setting And Short Circuit Setting Complete All As Specified And Directed By Engineer-In-Charge. 109 Supply And Fix In Replacementmccb 400 Amps , 4 Pole , 36 Ka , 50 Hz , 415 Voltincluding Under Voltage / Over Voltage Relay, Adjustable Overload Setting And Short Circuit Setting Complete All As Specified And Directed By Engineer-In-Charge. 110 Supply And Fix In Replacementmccb 250 Amps , 4 Pole , 25 Ka , 50 Hz , 415 Voltincluding Under Voltage / Over Voltage Relay, Adjustable Overload Setting And Short Circuit Setting Complete All As Specified And Directed By Engineer-In-Charge. 111 Supply And Fixing In Repair / Replacement Of Solar Street Light Fittings With Integrated 12 Watt Led Street Light System With Solar Pv Panel 100 Wp, Integrated Led Fitting With Li-Ion Battery 11.1 V 17 Ah , Mppt Based Solar Charge Controller, Motion Sensor And Tubular Pole Of Height 5 Mtrs Complete All As Specified And Directed By Engineer-In-Charge. 112 Supply And Fix In Repair On Load Changeover Switch 63 Amp 4 Pole, 415 V, 50 Hz In Sheet Steel Enclosure Forsurface Mounting With Padlocking Facilitywith The Connecting Accessories Complete All As Specified And Directed By Engineer-In-Charge. 113 Supply And Fix In Repair Air Termination, Single Pointed, Copper Rod 12Mm Dia And 300Mm Long Complete All As Specified And Directed By Engineer-In-Charge. 114 Supply And Fix In Repair Test Point Terminal Block Made Of Gun Metal Or Phosphorus Bronze Size 75X75x25 Mm Drilled And Screwed Including 3 Nos. 8Mm Dia 25Mm Long Hex. Head Screw Complete All As Specified And Directed By Engineer-In-Charge. 115 Supply And Fix In Repair Copper Strip 20 X 3.15Mm With Saddles And Fixing Screws Etc. For Roof Conductors And Down Conductors Above Ground Complete All As Specified And Directed By Engineer-In-Charge. 116 Supply And Fix In Replacement Of Starter Panel For 7.5 Hp Motor , 3 Phase , 415 V In Sheet Enclosure Including Phase Corretor Complete All As Specified And Directed By Engineer-In-Charge. 117 Supply And Fix Cable Jointing Kit For 1.1 Kv Grade Cable For Straight Through Joint Complete With Jointing Material Heat Shrink Type And Accessories Suitable For 3 ½Xlpe, Armoured, Al Conductor Cable Of Size 70 To 95 Sqmm, Outdoor Type Complete All As Specified And Directed By Engineer-In-Charge. 118 Supply And Fix Cable Jointing Kit For 1.1 Kv Grade Cable For Straight Through Joint Complete With Jointing Material Heat Shrink Type And Accessories Suitable For 3 ½Xlpe, Armoured, Al Conductor Cable Of Size 16 To 35 Sqmm, Outdoor Type Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fix Cable Jointing Kit For 1.1 Kv Grade Cable For Straight Through Joint Complete With Jointing Material Heat Shrink Type And Accessories Suitable For 3 ½Xlpe, Armoured, Al Conductor Cable Of Size 300 To 400 Sqmm, Outdoor Type Complete All As Specified And Directed By Engineer-In-Charge. 120 Supply And Fix Cable Jointing Kit For 1.1 Kv Grade Cable For Straight Through Joint Complete With Jointing Material Heat Shrink Type And Accessories Suitable For 3 ½Xlpe, Armoured, Al Conductor Cable Of Size 630 Sqmm, Outdoor Type Complete All As Specified And Directed By Engineer-In-Charge. 121 Supply And Fix In Repair On Load Changeover Switch 400 Amp 4 Pole , 415 V, 50 Hz In Sheet Steel Enclosure For Surface Mounting With Padlocking Facilitywith The Connecting Accessories Complete All As Specified And Directed By Engineer-In-Charge. 122 Supply And Fix In Repair On Load Changeover Switch 630 Amp 4 Pole , 415 V, 50 Hz In Sheet Steel Enclosure For Surface Mounting With Padlocking Facilitywith The Connecting Accessories Complete All As Specified And Directed By Engineer-In-Charge. 123 S&F In Repair Led Flood Light 120 Wattisi Marked, Enviromental Friendly High Efficient, Pressure Die Castwith Aluminium Extruded Heat Sink Ip66 Toughened Glasscomplete All As Specified And Directed By Engineer-In-Charge. 124 S&F In Repair Led Post Top Lantern 70 Watt With Die Castaluminum Pipe Spigot , Aluminium Pdc Heat Sink , Opal Diffuser Ip65complete All As Specified And Directed By Engineer-In-Charge. 125 M&L For Repair Of Submersiblepump Of Capacity 10 Hp , 3 Phase Shifting To Workshopcomplete Opening For Rewinding With Super Enamled Copper Wire Of Existing Size & Repair / Replacement Of Worn Out Parts Such As Shaft, Ball Bearing, Bush, Impellers, Coupling , Mechanical Seal, Jet Assembly Etc Including Re-Assembling And Refixing In Position Complete All As Specified And Directed By Engineer-In-Charge. 126 M&L For Repair Of Centrifugal Pump Of Capacity 5 Hp To 7.5 Hp , 3 Phase Shifting To Workshopcomplete Opening For Rewinding With Super Enamled Copper Wire Of Existing Size & Repair / Replacement Of Worn Out Parts Such As Shaft, Ball Bearing, Bush, Impellers, Coupling , Mechanical Seal, Jet Assembly Etc Including Re-Assembling And Refixing In Position Complete All As Specified And Directed By Engineer-In-Charge. 127 Taking Up Or Down Following Sizes Steel Tubing And Connections, Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed By Engineer-In-Charge.25 Mm Bore 128 All As Per Item No 127 Above But 20 Mm Bore Complete All As Specified And Directed By Engineer-In-Charge. 129 All As Per Item No 127 Above But 15Mm Bore Complete All As Specified And Directed By Engineer-In-Charge. 130 Supply, Laying And Fixing Gi Water Tubing Medium Grade With All Fittings And Fixed Complete To All Walls, Ceiling, Laid In Floors, Roof Etc Withfollowing Sizes Complete All As Specified And Directed By Engineer-In-Charge. 25 Mm Bore 131 All As Per Item No 130 Above But 20 Mm Bore Complete All As Specified And Directed By Engineer-In-Charge. 132 All As Per Item No 130 Above But15 Mm Bore Complete All As Specified And Directed By Engineer-In-Charge. 133 Supply, Installing Testing And Commissioning In Replacement Of Factory Made And Tested ( Including Cpri Test Cetified ) Indoortype Floor Mountedltpanel Board, Cubical Type Suitable For 415 Volts 3 Phase, 4 Wire 50Hz, Ac Supply System Having Busbar Chember With Insulated Al Busbar Of Rating Min. 1.5 Times The Rated Capacity Of Incomer Mccb For Phaseinstalled On Porcelin / Smc Insulators. The Panel Shall Be Dust And Vermin Proof Ip-54 Class Protection And Made Out Of 2.00 Mm Thickcrca Ms Sheetpowder Coated Finish Over One Coat Of Red Oxide Primer On Outside Surface And Painted Inside With Two Coat Of Red Oxide Primer, Front And Back Opening Type With Aproaches For Cable Entry With Double Door Shutter And Locking Arrangementsincluding Internal Wiring With Pvc Insulated Stranded Copper Conductor Cable Frls Is 694 Sheathed 1100V Grade Of Appropriate Size Complete All As Specified And Directed By Engineer-In-Charge..The Panel Shall Be Comprising Of Following:-Incoming- ( I ) Mains Mccb 4 Pole 400 Amps With Adjustable Setting, 415 Volts With Breaking Capacity 36 Ka. -01 No. ( Ii ) Digital Type Voltmeter 0-500 Volts And With Selector Switch-01 No. ( Iii ) Digital Amp Meterwith Cts & Built In Selector Switch-01 No. ( Iv ) Indication Lamp Ryb-01 Set.Outgoing- ( I ) Mccb 4 Pole 100 Amps, , 415 Volts With Breaking Capacity 16 Ka.-05No. ( Ii ) Mccb 4 Pole 63 Amps, 415 Volts With Breaking Capacity 16 Ka.-01 No. 134 Supply, Installing Testing And Commissioning In Replacement Of Factory Made And Tested ( Including Cpri Test Cetified ) Outdoortype Floor Mountedltpanel Board, Cubical Type Suitable For 415 Volts 3 Phase, 4 Wire 50Hz, Ac Supply System Having Busbar Chember With Insulated Al Busbar Of Rating Min. 1.5 Times The Rated Capacity Of Incomer Mccb For Phaseinstalled On Porcelin / Smc Insulators. The Panel Shall Be Dust And Vermin Proof Ip-54 Class Protection And Made Out Of 3.15 Mm Thickcrca Ms Sheetpowder Coated Finish Over One Coat Of Red Oxide Primer On Outside Surface And Painted Inside With Two Coat Of Red Oxide Primer, Front And Back Opening Type With Aproaches For Cable Entry With Double Door Shutter And Locking Arrangementsincluding Internal Wiring With Pvc Insulated Stranded Copper Conductor Cable Frls Is 694 Sheathed 1100V Grade Of Appropriate Size Complete All As Specified And Directed By Engineer-In-Charge.The Panel Shall Be Comprising Of Following:-Incoming- ( I ) Mains Mccb 4 Pole 125 Amps With Adjustable Setting, 415 Volts With Breaking Capacity 36 Ka. -01 No. ( Ii ) Digital Type Voltmeter 0-500 Volts And With Selector Switch-01 No. ( Iii ) Digital Amp Meterwith Cts & Built In Selector Switch-01 No. ( Iv ) Indication Lamp Ryb-01 Set.Outgoing- ( I ) Mccb 4 Pole 40 Amps, 415 Volts With Breaking Capacity 16 Ka.-03No. ( Ii ) Mccb 4 Pole 63 Amps, 415 Volts With Breaking Capacity 16 Ka.-01 No. 135 Supply, Installing Testing And Commissioning In Replacement Of Factory Made And Tested ( Including Cpri Test Cetified ) Outdoortype Floor Mountedltpanel Board, Cubical Type Suitable For 415 Volts 3 Phase, 4 Wire 50Hz, Ac Supply System Having Busbar Chember With Insulated Al Busbar Of Rating Min. 1.5 Times The Rated Capacity Of Incomer Mccb For Phaseinstalled On Porcelin / Smc Insulators. The Panel Shall Be Dust And Vermin Proof Ip-54 Class Protection And Made Out Of 3.15 Mm Thickcrca Ms Sheetpowder Coated Finish Over One Coat Of Red Oxide Primer On Outside Surface And Painted Inside With Two Coat Of Red Oxide Primer, Front And Back Opening Type With Aproaches For Cable Entry With Double Door Shutter And Locking Arrangementsincluding Internal Wiring With Pvc Insulated Stranded Copper Conductor Cable Frls Is 694 Sheathed 1100V Grade Of Appropriate Size Complete All As Specified And Directed By Engineer-In-Charge.The Panel Shall Be Comprising Of Following:-Incoming- ( I ) Mains Mccb 4 Pole 315 Amps With Adjustable Setting, 415 Volts With Breaking Capacity 36 Ka. -01 No. ( Ii ) Digital Type Voltmeter 0-500 Volts And With Selector Switch-01 No. ( Iii ) Digital Amp Meterwith Cts & Built In Selector Switch-01 No. ( Iv ) Indication Lamp Ryb-01 Set.Outgoing- ( I ) Mccb 4 Pole 125 Amps, 415 Volts With Breaking Capacity 16 Ka.-02No. ( Ii ) Mccb 4 Pole 160 Amps, 415 Volts With Breaking Capacity 16 Ka.-02No. ( Iii ) Mccb 4 Pole 200 Amps, 415 Volts With Breaking Capacity 16 Ka.-01 No. 136 Supply And Fix Cable Duct Cover Made Of Iron Of Size 320Mm X 800 Mm Of Thickness 3.0 Mm Complete All As Specified And Directed By Engineer-In-Charge. 137 M&Lfor Providing, Pcc 1:3:6 Type C-1 Using 20 Mm Graded Stone Aggreat, For Damaged Earth Pit Chamber With Fair Finish Internal Surface Of Concrete Chamber Of Earthcomplete All As Specified And Directed By Engineer-In-Charge. 138 S & F Rubber Insulation Mat Of Size 1.8 Mtr X0.9Mtr Wide 19Mm Thick Red Colour Isi Marked Embozzed For Up To 15 Kv Complete All Asspecifiedand As Directed By Engineer-In-Charge. 139 M&L For Painting Of Water Supply Pipe Lines Of Any Size & Length Upto20 Rm Of Both Pump Houses With Two Coat Of Synthetic Enamal Paint Of Any Tint And Highlighting The Incoming And Outgoing Water Pipes From Pumphouse By Making The Directional Aerrows & Writing Alphabets I & O ( Not Less Than 5 Cm Height ) With Any Light Colour Paint Complete All As Specified And Directed By Engineer-In-Charge. 140 Supply And Fixing Led Light Fitting 1X16 Watt Flameproof, Cmri Certified Recommended For Gas / Vapor Group Of Iia & Iiib, Zone 1 & 2 And Ip 65 Protection With Die Cast Aluminum Hosing With Heat Resistant Toughened Glass With Led Tube Light Fixtures Driver, Holders, Connector Etc. Complete With All Accessories Prewired And Including Connecting Up With Three Core Flexible Copper Conductor Cable With Suitable Size Complete All As Specified And Directed By Engineer-In-Charge. 141 Supply And Fix In Replacement Switch Flame Proof Rotary Type With Termination Box In Lm6, 16A, Single Pole 250V Complete All As Specified And Directed By Engineer-In-Charge. 142 M&L For Chemical Analysis Of Water Sample Collected From Mes Borewellto Check The Tds And Impurities Level In The Sample Complete All As Specified And Directed By Engineer-In-Charge. 143 Supply And Fix In Replacement Of Flame Proof Exhaust Fan 300 Mm Sweep Iron Bodywith All Accessories Complete All As Specified And Directed By Engineer-In-Charge. 144 S&F In Replacement Of Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Cross-Sectional Area 6 Sqmm 2 Coreall As Specified And Directed By Engineer-In-Charge. 145 M&Lfor Providingdisplay Board Of Size 1M X 1M X1 Cm Madeup With Acrylic Sheetmaterial Consisting OfPump House No 1 & 2Ge ( Af ) Faridabadand Mes Logo In Capital Letterat The Top Complete With Fixing Arrangements To The Wall Complete All As Specified And Directed By Engineer-In-Charge. 146 M&Lfor Providingdisplay Board Of Size 1M X 1M X1 Cm Madeup With Acrylic Sheetmaterial Consisting OfPower House 11 Kv Ge ( Af ) Faridabad In Capital Letterat The Top With Fixing Arrangements To The Wall Complete All As Specified And Directed By Engineer-In-Charge. 147 S&F In Replacement Of Pvc Copper Cable For Submersible Pump Ofsize 6 Sqmm 3 Core Flatcomplete All As Specified And Directed By Engineer-In-Charge. 148 M&L For Rectification Of Leakage Of Ug Water Pipe Lines Of Size 80 To 150 Mm Bore Of Any Description Such As Ci / Di / Gipipe Line At Any Location Including Necessary Excavation, Earth Work, Dewatering, Cutting Existing Pipe Lines Including Repairs With Suitable Flanges, Joints Or Any Other Material Complete All As Specified And Directed By Engineer-In-Charge. 149 All As Per Item No 148 Above But But For Size Of 15 Mm To50mm Dia Pipe Line Complete All As Specified And Directed By Engineer-In-Charge. 150 M&L For Rectification Of Leakage Complaints Of Sluice Valves By Opening Removing Gland Plate And Pumping / Taking Water From Water Pit And Proving Gland Packing And Refitting By Replacing Worn Out Bolts, Nuts And Washers Complete All As Specified And Directed By Engineer-In-Charge.Note: Bolts, Nuts And Washers Will Be Paid Under Relevant Items Of Schedule 151 M&L For Dewatering The Existing U / G Sump Of 25000 Ltrs Capacity And Cleaning The Internal Surface Of Sump For Removingscales, Funges, Mud And Other Foreign Material , Scrubbing With Water Using Wire Brush And Watering The Surfaces With Mixture Of Bleaching Powder And Water , Finally Washing With Fresh Water And Treating With One Coat Of Lime Wash To Internal Wall And Bottom Surfaces Etccomplete For One Time, Writing In Enamel Paint Note In Block Capital Letter As Cleaned On ( Date ) And Due Date Etc, Height Not Less Than 5 Cm Complete All As Specified And Directed By Engineer-In-Charge. 152 Repair Maintainance Of Oil Cooled Servo Voltage Stablizer Of Capacity400 To 630 Kva 3 Phase By Isolating , Disconnecting Of Input / Output , Supply Cable, Opening Of Top Of Voltage Stablizer, Detecting Of Fault , U / S Component In Control Panel / Dimmerstat / Pcb Etc, Cleaning Of Serviceable Parts / Component All As Specified And Directed. Note:- The Replacement Spare Parts Shall Be Measured And Paid Separately Complete All As Specified And Directed By Engineer-In-Charge. 153 Supply Only Spare Part Of The Voltage Stablizer 400 / 630 Kvacomplete All As Specified And Directed By Engineer-In-Charge As Following:-Rc Network 154 Ac Synchronous Motor 10 Kg 155 Spring Loaded Finger 156 Microproccessor Based Eletronic Control Board 157 Demolition Of Brickwork Or Stone / Boulder Masonry, Built In Cement Mortar Including All Quoins, Arches, Pillars, Etc, But Including Ashlar Facings, Dressed Stonework And Precast Concrete Articlescomplete All As Specified And Directed By Engineer-In-Charge 158 M&L For Brickwork With Subclass B Bricks ( Old Size Bricks ) , Straight Or Curved On Plan Exc 6M Mean Radius, Built In Cm 1:6 Complete All As Specified And Directed By Engineer-In-Charge 159 All As Per Item No 158 Above Here In But Except Bricks Complete All As Specified And Directed By Engineer-In-Charge 160 M&L For Brick Work With Sub Class ‘B’ Bricks ( Old Size Brick ) Straight Or Curved On Plan To Any Radius In Half Bricks Thick Walls, Built In Cm 1:4 Complete All As Specified And Directed By Engineer-In-Charge 161 M&L For Cutting Holes Exc 400 Sq Cm But N Exc 0.10 Sqminto Or Through Brick Walls Built In Cement Mortar Or Cement Lime Mortar And Stone Walls Built In Lime Mortar Or Walls Of Lime Concrete Complete All As Specified And Directed By Engineer-In-Charge 162 M&L For Making Good In Cm 1:4 Under Cills Or Over Arches, Lintels And Bressummers. Including Allpinning When Necessary Complete All As Specified And Directed By Engineer-In-Charge 163 Taking Down Cement Plaster Of Any Description On Concrete Surfaces Such As Soffit Of Rcc Slab, Chajjas And Brick Walls Etc Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc Complete All As Specified And Directed By Engineer-In-Charge 164 M&L, Rendering 15Mm Thick In Cm 1:4 Onof Brick Work Or Concrete Surfacefinish Ever And Smooth ( W / O Using Extra Cement ) Incl Wpc As Per User Manual At Any Height Etc Complete All As Specified And Directed By Engineer-In-Charge. ( Wpc Will Be Measured And Paid Separately ) . 165 Supply Only Liquid Water Proofing Compound Complete All As Specified And Directed By Engineer-In-Charge 166 M&L For Rendering 5 Mm Thick In Cement And Sand Mortar 1:3 Onother Than Fair Faces Of Brick Work Or Cement Concrete Surfaces Including Finishing The Surface Even And Smooth On Ceilings, Complete All As Specified And Directed By Engineer-In-Charge 167 M&L For Rendering 15 Mm Thick Cement Plaster In Cm 1:6 Onbrick Work Or Concrete Surfaces Including Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer-In-Charge 168 M&L For 3Mm Thick Wall Care Putty On Wall Complete All As Specified And Directed By Engineer-In-Charge. 169 M&L For 3Mm Thick Wall Care Putty On Ceiling Complete All As Specified And Directed By Engineer-In-Charge. 170 M&L For Preparation Of New Plastered Or Concrete Surfaces Of Walland Applying Two Coats Of Cement Base Paint Upto Triple Storey Height, Complete All As Specified And Directed By Engineer-In-Charge. 171 M&L For Preparaing Old Surface ( Plastered Or Unplastered ) By Washing, Rubbing Down And Stopping Of Painted Surfaces Of Walls And Applying One Coat Of Cement Base Paint, Complete Upto Triple Storey Height, All As Specified And As Directed By Engineer-In-Charge 172 M&L For Preparation Of New Plastered Surfaces Of Walland Applying Two Coats Of Oil Bound Distemper Over A Coat Of Primer, Complete All As Specified And Directed By Engineer-In-Charge. 173 M&L For Preparaing Old Surface ( Plastered Or Unplastered ) By Washing, Rubbing Down And Stopping Of Distempered And Painted Surfaces And Applying One Coat Of Oil Bound Distemper On Walls, Complete All As Specified And As Directed By Engineer-In-Charge 174 M&L For Preparaing Old Surface ( Plastered Or Unplastered ) By Washing, Rubbing Down And Stopping Of Distempered And Painted Surfaces And Applying One Coat Of Oil Bound Distemper On Ceilling Surfaces, Complete All As Specified And As Directed By Engineer-In-Charge 175 M&L For Preparaing New Surface ( Plastered Or Unplastered ) By Washing, Rubbing Down And Stopping Of Distempered And Applying 2 Coat Of White Wash On Ceiling, Complete All As Specified And Directed By Engineer-In-Charge 176 M&L For Non Skid Ceramic Tiles 7 To 8 Mm Thick Any Coloured / Printed ( Square / Rectangular ) Area Of Each Tile Exc 0.06 Sqm But Not Exc 0.18 Sqm As In Floor Of Shade & Designed As Approved By Ge, Set And Jointed In Neat Cement Slurry And Pointed With White Cement With Colour Pigment To Match The Colour Of Tiles, Over 15 Mm Thick Screed Bed In Cement Mortar ( 1:4 ) In Floors, Incl Dismantling / Demolition And Rubbish Off The Primises Etc Complete All As Specified And Directed By Engineer-In-Charge 177 M&L For Glazed Ceramic Tile 450 X 300 X 06-7Mm Thick ( Coloured ) On Vertical Surfaces Such Aswall, Dados Etc Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Shade Of Tiles Over And Including 10 Mm Thick Screed Bed In Cement And Sand Mortar 1:4, And Dismantlling Of Existing Tiles Complete All As Specified And As Directed By Engineer-In-Charge. 178 Taking Down And Refixing Of Shuttersin Same Openingafter Easing And Adjusting Of Any Description Exc 1 Sq. M And N Exc 2 Sq. M Each Including Resecuring / Changing Of Builders Hardware Complete All As Specified And Directed By Engineer-In-Charge 179 M&L For 18 To 20 Mm Thick Granite ( Of Any Type ) Work ( Table Rubbed And Polished ) In Steps, Jambs, Pillars, Windowcills, Cooking Platforms, Wash Basin Platformand Like In Cement Mortar ( 1:4 ) Including Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade Complete All As Specified And Directed By Engineer-In-Chargenote :- 1. Contractor Shall Be Bounded To Carryout Repair / Maint Upto G+3 Storey Building And The Rate Shall Be Deemed Including Scafolding / Double Scafolding, Safety Equipments And Misc Accessories.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT TO CERTAIN LT EQUIPMENT ALONGWITH ELECTRICAL FITTINGS AND REPAIR TO CERTAIN B/R WORKSAT AF STATION NARAINA AND AFND IN AOR OF GE (AF) FARIDABAD
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) completeincluding all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed by Engineer-in-Charge.
2M&L for point wiring light point / bell point with single core PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through in existing concealed conduit, fixed on wall, ceiling with GI saddles GI screws, rawal plugs (concealed conduit wiring) with all fittings including Tee, junction boxes and provision of modular metal flush boxof suitable sizemodular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with stranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed by Engineer-in-Charge for following :-.NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
3All as per item No 2 above but 5 Amp socket outlet, independent complete all as specified and directed by Engineer-in-Charge.
4All as per item No 2 above but on the same board complete all as specified and directed by Engineer-in-Charge.
5All as per item No 2 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
6M&L switch flush type bell push 1 module modular typebutton 6 amp after dismantling old one complete all as specified and directed by Engineer-in-Charge.
7M&L for socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed by Engineer-in-Charge.
8M&L for socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed by Engineer-in-Charge.
9M&L for switch 6 amps modular type one one way complete all as specified and directed by Engineer-in-Charge.
10M&L for switch 16 amps modular type one one way complete all as specified and directed by Engineer-in-Charge.
11M&L for modular type fan regulator (Step type) , 120 W-1 module complete all as specified and directed by Engineer-in-Charge.
12M&L metal flush box 3 module complete all as specified and directed by Engineer-in-Charge.
13M&L metal flush box 6 module complete all as specified and directed by Engineer-in-Charge.
14M&L metal flush box 12 module complete all as specified and directed by Engineer-in-Charge.
15M&L for white cover plate with frame, 12 module complete all as specified and directed by Engineer-in-Charge.
16M&L for white cover plate with frame, 6 module complete all as specified and directed by Engineer-in-Charge.
17M&L for white cover plate with frame, 3 module complete all as specified and directed by Engineer-in-Charge.
18S&F bell Ding dong AC 230Volts single pole complete all as specified and directed by Engineer-in-Charge.
19S &F in replacement switch socket combination 16A,6pin,3module 220/230 Volts complete all as specified and directed by Engineer-in-Charge.
20S&F in replacement switch piano type 5 amp SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
21S&Fin replacement switch 15 Amps SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
22S&F in replacement socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
23S&F in replacement socket outlet 2-in-1, 3 pin 5 amp and 15 amps complete all as specified and directed by Engineer-in-Charge.
24M&L for bell push flush type 5/6 amps one way complete all as specified and directed by Engineer-in-Charge.
25S&F in replacement of wall mounting slim 18/20 Watt 4 feet led Batten luminaire , white with engineering plastic batten with white acrylic cover sleek design & high efficiency for wall and surface mounted applicationsall as specified and directed by Engineer-in-Charge.
26S&F in replacement of wall mountingLED slim 9/10 Watt 2 feet, white with high efficient LEDs & glare free opal diffuser complete all as specified and directed by Engineer-in-Charge.
27S & F in replacement enviroment friendly recess/surface mounting LED flat panel 2"x2", cool white with high efficient LEDs & glare free opal diffuser (36 W) PF>0.95 driver life >25000 Hours, operating range 140v to 280 V includingall accessaries complete all as specified and directed by Engineer-in-Charge.
28S& F LED fitting bulkhead 10 Watt single phase 50 Hz IP 66 outdoor type complete all as specified and directed by Engineer-in-Charge.
29S&F in replacement of Recesses mountingLED slim round downlighter 12 Watt warmwhite with high efficient LEDs & glare free opal diffuser complete all as specified and directed by Engineer-in-Charge.
30S&F in replacement of Recesses mountingLED slim square downlighter 12 Watt warmwhite with high efficient LEDs & glare free opal diffuser complete all as specified and directed by Engineer-in-Charge.
31S&F in replacement MCB SP 5 to 32 Amps,240 volts curve "C",breaking capacity 10KAcomplete all as specified and directed by Engineer-in-Charge.
32S&F in replacement MCB SPN32 to 63 Amps,240 volts,curve "C", breaking capacity 10 KA, complete all as specified and directed by Engineer-in-Charge.
33S&F in replacement MCB TP 40 to 63 Amps,415 volts curve "C",breaking capacity 10KAcomplete all as specified and directed by Engineer-in-Charge.
34S&F in replacement MCB TPN 40 Amps,415 volts curve "C",breaking capacity 10KA, complete all as specified and directed by Engineer-in-Charge.
35S&F in replacement MCB TPN 63 Amps,415 volts curve "C",breaking capacity 10KA,complete all as specified and directed by Engineer-in-Charge.
36S&F in replacement MCB 4 Pole 100 Amps,415 volts curve "C",breaking capacity 10KA, complete all as specified and directed by Engineer-in-Charge.
37S&F in replacement MCCB,Four pole,415 volts, 125 Amps , curve "C",breaking capacity 10 KA, complete all as specified and directed by Engineer-in-Charge.
38S&F sheet metal enclosuresDBDouble door Verticle distribution type,04 way,TPN DB , IP43, 415V & suitable for MCCB TP as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturercomplete all as specified and directed by Engineer-in-Charge.
39S&F sheet metal enclosuresDBDouble doordistribution type,04 way,TPN DB , IP43, 415V & suitable for MCB TP as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed by Engineer-in-Charge.
40S&F sheet metal enclosuresDBDouble doordistribution type,06 way,TPN DB , IP43, 415V & suitable for MCB TP as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed by Engineer-in-Charge.
41S&F in replacement sheet metal enclosuresDBDouble door type 8 way SPN 240 voltincluding 200 Amps rated bus bar with neutral link complete all as specified and directed by Engineer-in-Charge.
42S&F in replacement sheet metal enclosuresDBDouble door type 4 way SPN 240 voltincluding 200 Amps rated bus bar with neutral link complete all as specified and directed by Engineer-in-Charge.
43S&F for ceiling rose surface bakelite 65x50mm two to three terminals complete all as specified and as directed by Engr-in-Charge.
44S& F in repair casing capping of size 15 mmto cover the copper conductor in wall complete all as specified and directed by Engineer-in-Charge.
45S&F in replacement of LED electronic driver suitable for 20 Watt LED batten fitting complete all as specified and directed by Engineer-in-Charge.
46S&F in replacement of LED electronic driver suitable for 36 Watt LED (2"x2") recesses mountedfitting complete all as specified and directed by Engineer-in-Charge.
47Supply and fix external wall mounted switch board 15 Amps consisting of one number 15 Amps switch and socket including frame and sheet complete with screws al as specified and as directed by Engineer-in-Charge.
48Supply and fix external wall mounted switch board 5 Amps consisting of one number 5 Amps switch and socket including frame and sheet complete with screws al as specified and as directed by Engineer-in-Charge.
49Taking down pressure pump motor of capacity upto 1 HP, single phase , 230 Volt all as per specified and as directed by Engineer-in-Charge.
50M&L for rewinding of presume pump motor of capacity upto 1 HP single phase , 230 Volt all as per specified and as directed by Engineer-in-Charge.
51M&L for refixing presume pump motor of capacity upto 1 HP single phase , 230 Volt all as per specified and as directed by Engineer-in-Charge.
52M&L earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggalvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dollyall as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc complete all as specified and directed by Engineer-in-Charge.
53S&F ISI marked self adhesive PVC electrical insulation Tape roll of 25 mm wide,0.125 mm thick and 25 RM lengthcomplete all as specified and directed by Engineer-in-Charge.
54Taking down carefully water heater storage type 25 ltrs/50 Ltrs capacity for repair and over hauling and opening to geysers and comprising of heating element thermo stat switch, electric connection cleaning and descaling with descaling solution the geysers tank and checking of leakage on pressure at 150 PSI and testing for smooth functioning complete all as specified and directed by Engineer-in-Charge.
55S&F in replacement of heating element 2.00 KW capacity 230 volt suitable for geysers any type as per site requirement ISI mark complete all as specified and directed by Engineer-in-Charge:-
56All as per item No 55above but 1.5 KW capacity 230 volt complete all as specified and directed by Engineer-in-Charge.
57S&F in replacement thermostat switch connection any type suitable for geyser of any size/model complete all as specified and directed by Engineer-in-Charge.
58S&F in replacement of geyser assembly any make any type for 25 ltrs/50 ltrs capacity water heater including replacement of rubber seal complete all as specified and directed by Engineer-in-Charge.
59Supply and fixing in replacement of indicator lamp (Pilot type)for 25 ltrs water heater complete all as specified and directed by Engineer-in-Charge.
60Supply and fixing in replacement of PVC insulated copper conductor cable 4 Sqmm size 3 core grade (For Geyser) complete all as specified and directed by Engineer-in-Charge.
61S&F in replacement of water storage tank of suitable for 25ltrs capacity incl glass wool complete all as specified and directed by Engineer-in-Charge.
62S&F in replacement of water storage tank of suitable for 50ltrs capacity incl glass wool complete all as specified and directed by Engineer-in-Charge.
63Supply & fixing in replacement ofbottom cover suitable cylindrical type geyser for 25 Ltrs/ 50 Ltrscapacity geyser all as specified and directed by Engineer-in-charge
64All as per item No 63 above but of capacity 50 Ltrscomplete all as specified and directed by Engineer-in-Charge.
65M&L for preparation of external surface of geyser body 25/50 ltrs rubbing the rusted surface and painting with two coats of spray paint with synthetic enamel paint over a coat of metal primer matching with existing colour complete all as specified and directed by Engineer-in-Charge.
66S& F heavy duty PVC pipe suitable for hot water flow for geysers of capcity 25 to 50 ltrs all as specified and as directed by Engineer-in-charge
67S& F plug top 3 pin ,15 Amps rating all as specified and as directed by Engineer-in-charge
68S& F plug top 3 pin ,5 Amps rating all as specified and as directed by Engineer-in-charge
69S&F in replacement AC Box with plug and socket complete with 16 to 32 Amp SP MCB C Curve 10 KA complete all as specified and directed by Engineer-in-Charge.
70S& F water heater body metallic type suitable for 25 ltr capacity including glass wool for insulation top and bottom plates complete all as specified and directed by Engineer-in-Charge.
71S&F heating element 2-3 KW thread type/ cone type compatible with 10 to 300 ltr solar water heater tank complete all as specified and directed by Engineer-in-Charge.
72Supply and in install heating element 2-3 KW thread type/ cone type compatible with instant water heater complete all as specified and directed by Engineer-in-Charge.
73S&F in repair wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415 Volts complete all as specified and directed by Engineer-in-Charge.
74Supply and fixing in replacement of capacitor of following sizes complete all as specified and directed by Engineer-in-Charge. (a).2.5 Mfd.
75All as per item No 74 above but 3.15 Mfd complete all as specified and directed by Engineer-in-Charge.
76M&L for rewinding of burnt fan1200 mm/1400 mm sweepwith super enameled copper wire winding, rubber real, U’ clamps, nuts, bolts, washers and split pins of suitable size as per details of any make/model complete all as specified and directed by Engineer-in-Charge.
77Taking down ceiling fan 1200 mm/1400 mm sweep removing cleaning of dust, properly cleaning and greasing of bearing and connecting up complete all as specified and directed by Engineer-in-Charge.
78Supply in replacement for rewinding of exhaust fan as per details given below with supper enameled copper wireof suitable size of any make/type/model including transportation complete all as specified and directed by Engineer-in-Charge :-(a) Exhaust fan 300mm (12’size)
79All as per item No 78 abive butExhaust fan 380mm (15” size) complete all as specified and directed by Engineer-in-Charge.
80Supply in replacementfor exhaust fan Louver of following size complete all as specified and directed by Engineer-in-Charge. (a) 380 mm
81All as per item No 80 above but 300 mm complete all as specified and directed by Engineer-in-Charge.
82Taking down carefully defective wall mounted fan of any size and make and oiling greasing after opening and refixing the fan to its position after repair and testing complete all as specified and directed by Engineer-in-Charge.(a)Wall fan of size 400mm
83All as per item No 82 above but Wall fan of size 300mm complete all as specified and directed by Engineer-in-Charge.
84M&L for rewinding of wall mounted fan given below with super enameled copper wire Including of suitable of size of any make/type model complete all as specified and directed by Engineer –in-charge :- (a)Wall fan of size 400mm
85All as per item No 84 above but Wall fan of size 300mm complete all as specified and directed by Engineer-in-Charge.
86Supply and fixing in replacementventilation fan plastic 250 mm sweepbody 240 v 50 Hz single phase all as specified and directed by Engineer-in-Charge.
87Supply and fixing in replacementventilation fan plastic 300 mm sweepbody 240 v 50 Hz single phase all as specified and directed by Engineer-in-Charge.
88Supply and fixing in replacement 450mm sweep wall mounted fan plastic body 240 v single phase 50 Hz all as specified and directed by Engineer-in-Charge.
89S&F in replacement for wall mounted fan bushes ,shaft and suitable body cover ,moving partcomplete all as specified and directed by Engineer-in-Charge.
90Supply only ISI marked self adhesive PVC electrical insulation Tape roll of 25 mm wide,0.125 mm thick and 25 RM lengthcomplete all as specified and directed by Engineer-in-Charge.
91S&F decorative 45 W LED Strip light including drivers and necessary connections non-integral flexible type with high brihtness for indoor and outdoor applications. Strip can be cut at marked interval to suit desired length.all as specified and as directed by Engineer-in-Charge
92M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2.5 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 sqmm cable alongwith one run of 2.5 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length)
93M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length).
94S&F in repair LED 40 wattpost top lantern with die cast aluminum spigot ,spun aluminium caoted top cover heat sink ,opal diffuser and clear acrylic IP65 complete all as specified and directed by Engineer-in-Charge.
95S&F in repair LED 60 wattpost top lantern with die cast aluminum spigot ,spun aluminium caoted top cover heat sink ,opal diffuser and clear acrylic IP65 complete all as specified and directed by Engineer-in-Charge.
96S&F in replacement ofsingle core FRLS cable PVCunsheathed with copper conductor of size 1.5 Sqmmand drawing into existing conduit complete all as specified and directed by Engineer-in-Charge.
97S&F in replacement ofsingle core FRLS cable PVCunsheathed with copper conductor of size 2.5 Sqmmand drawing into existing conduit complete all as specified and directed by Engineer-in-Charge.
98Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out complete all as specified and directed by Engineer-in-Charge.
99Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engineer-in-Charge.
100Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engineer-in-Charge.
101M & Lfor brick protection with sub class "B" brickslaid dry flat over electric cable in trenches complete all as specified and directed by Engineer-in-Charge.
102M & Labour for sand cushioning with a layer of sand 80mm thickconsolidated before laying of cable and 150mm thickconsolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as specified and directed by Engineer-in-Charge.
103Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
104Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 630 sq mm x 3.5 core complete all as specified and directed by Engineer-in-Charge.
105Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
106Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
107Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
108Supply and fix in replacement MCCB 630 Amps ,4 Pole ,50 KA ,50 Hz ,415 Voltincluding under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
109Supply and fix in replacementMCCB 400 Amps ,4 Pole ,36 KA ,50 Hz ,415 Voltincluding under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
110Supply and fix in replacementMCCB 250 Amps ,4 Pole ,25 KA ,50 Hz ,415 Voltincluding under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
111Supply and fixing in repair/replacement of solar street light fittings with integrated 12 Watt LED street light system with solar PV Panel 100 WP, integrated LED fitting with Li-Ion Battery 11.1 V 17 Ah , MPPT based solar charge controller,Motion Sensor and tubular pole of height 5 Mtrs complete all as specified and directed by Engineer-in-Charge.
112Supply and fix in repair on load changeover switch 63 amp 4 pole,415 V,50 Hz in sheet steel enclosure forsurface mounting with padlocking facilitywith the connecting accessories complete all as specified and directed by Engineer-in-Charge.
113Supply and fix in repair Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed by Engineer-in-Charge.
114Supply and fix in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engineer-in-Charge.
115Supply and fix in repair Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge.
116Supply and fix in replacement of starter panel for 7.5 HP motor ,3 phase ,415 V in sheet enclosure including phase corretor complete all as specified and directed by Engineer-in-Charge.
117Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
118Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½XLPE, armoured, Al conductor cable of size 16 to 35 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
119Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½XLPE, armoured, Al conductor cable of size 300 to 400 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
120Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½XLPE, armoured, Al conductor cable of size 630 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
121Supply and fix in repair on load changeover switch 400 amp 4 pole ,415 V,50 Hz in sheet steel enclosure for surface mounting with padlocking facilitywith the connecting accessories complete all as specified and directed by Engineer-in-Charge.
122Supply and fix in repair on load changeover switch 630 amp 4 pole ,415 V,50 Hz in sheet steel enclosure for surface mounting with padlocking facilitywith the connecting accessories complete all as specified and directed by Engineer-in-Charge.
123S&F in repair LED flood light 120 wattISI marked,enviromental friendly high efficient,pressure die castwith aluminium extruded Heat sink IP66 toughened glasscomplete all as specified and directed by Engineer-in-Charge.
124S&F in repair LED post top lantern 70 watt with die castaluminum pipe spigot ,aluminium PDC heat sink ,opal diffuser IP65complete all as specified and directed by Engineer-in-Charge.
125M&L for repair of Submersiblepump of capacity 10 HP ,3 phase shifting to workshopComplete opening for rewinding with super enamled copper wire of existing size & repair/replacement of worn out parts such as shaft,Ball bearing, bush, impellers, coupling ,mechanical seal,jet assembly etc including re-assembling and refixing in position complete all as specified and directed by Engineer-in-Charge.
126M&L for repair of centrifugal pump of capacity 5 HP to 7.5 HP ,3 phase shifting to workshopComplete opening for rewinding with super enamled copper wire of existing size & repair/replacement of worn out parts such as shaft,Ball bearing, bush, impellers, coupling ,mechanical seal,jet assembly etc including re-assembling and refixing in position complete all as specified and directed by Engineer-in-Charge.
127Taking up or down following sizes steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge. 25 mm bore
128All as per item No 127 above but 20 mm bore complete all as specified and directed by Engineer-in-Charge.
129All as per item No 127 above but 15mm bore complete all as specified and directed by Engineer-in-Charge.
130Supply, laying and fixing GI water tubing medium grade with all fittings and fixed complete to all walls,ceiling,laid in floors,roof etc withfollowing sizes complete all as specified and directed by Engineer-in-Charge. 25 mm bore
131All as per item No 130 above but 20 mm bore complete all as specified and directed by Engineer-in-Charge.
132All as per item No 130 above but15 mm bore complete all as specified and directed by Engineer-in-Charge.
133Supply, installing testing and commissioning in replacement of factory made and tested(Including CPRI test cetified) indoortype floor mountedLTpanel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chember with insulated AL busbar of rating min. 1.5 times the rated capacity of incomer MCCB for phaseinstalled on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 2.00 mm thickCRCA MS sheetpowder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangementsincluding internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size complete all as specified and directed by Engineer-in-Charge..The panel shall be comprising of following:- INCOMING- (i) Mains MCCB 4 pole 400 Amps with adjustable setting, 415 Volts with breaking capacity 36 KA. -01 No. (ii) Digital type voltmeter 0-500 volts and with selector switch-01 No. (iii) Digital Amp meterwith CTs & built in selector switch-01 No. (iv) Indication lamp RYB-01 Set. OUTGOING- (i) MCCB 4 pole 100 Amps,, 415 Volts with breaking capacity 16 KA.-05No. (ii)MCCB 4 pole 63 Amps, 415 Volts with breaking capacity 16 KA.-01 No.
134Supply, installing testing and commissioning in replacement of factory made and tested(Including CPRI test cetified) outdoortype floor mountedLTpanel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chember with insulated AL busbar of rating min. 1.5 times the rated capacity of incomer MCCB for phaseinstalled on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm thickCRCA MS sheetpowder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangementsincluding internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size complete all as specified and directed by Engineer-in-Charge.The panel shall be comprising of following:- INCOMING- (i) Mains MCCB 4 pole 125 Amps with adjustable setting, 415 Volts with breaking capacity 36 KA. -01 No. (ii) Digital type voltmeter 0-500 volts and with selector switch-01 No. (iii) Digital Amp meterwith CTs & built in selector switch-01 No. (iv) Indication lamp RYB-01 Set. OUTGOING- (i) MCCB 4 pole 40 Amps, 415 Volts with breaking capacity 16 KA.-03No. (ii)MCCB 4 pole 63 Amps, 415 Volts with breaking capacity 16 KA.-01 No.
135Supply, installing testing and commissioning in replacement of factory made and tested(Including CPRI test cetified) outdoortype floor mountedLTpanel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chember with insulated AL busbar of rating min. 1.5 times the rated capacity of incomer MCCB for phaseinstalled on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm thickCRCA MS sheetpowder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangementsincluding internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size complete all as specified and directed by Engineer-in-Charge.The panel shall be comprising of following:- INCOMING- (i) Mains MCCB 4 pole 315 Amps with adjustable setting, 415 Volts with breaking capacity 36 KA. -01 No. (ii) Digital type voltmeter 0-500 volts and with selector switch-01 No. (iii) Digital Amp meterwith CTs & built in selector switch-01 No. (iv) Indication lamp RYB-01 Set. OUTGOING- (i) MCCB 4 pole 125 Amps, 415 Volts with breaking capacity 16 KA.-02No. (ii) MCCB 4 pole 160 Amps, 415 Volts with breaking capacity 16 KA.-02No. (iii)MCCB 4 pole 200 Amps, 415 Volts with breaking capacity 16 KA.-01 No.
136Supply and fix cable duct cover made of iron of size 320mm x 800 mm of thickness 3.0 mm complete all as specified and directed by Engineer-in-Charge.
137M&Lfor Providing,PCC 1:3:6 type C-1 using 20 mm graded stone aggreat,for damaged earth pit chamber with fair finish internal surface of concrete chamber of earthcomplete all as specified and directed by Engineer-in-Charge.
138S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 19mm thick red colour ISI marked embozzed for up to 15 KV complete all asspecifiedand as directed by Engineer-in-Charge.
139M&L for painting of water supply pipe lines of any size & length upto20 RM of both pump houses with two coat of synthetic enamal paint of any tint and highlighting the incoming and outgoing water pipes from pumphouse by making the directional aerrows & writing alphabets "I" & "O" (not less than 5 cm height) with any light colour paint complete all as specified and directed by Engineer-in-Charge.
140Supply and fixing LED light fitting 1x16 Watt flameproof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
141Supply and fix in replacement Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge.
142M&L for Chemical analysis of water sample collected from MES borewellto check the TDS and impurities level in the sample complete all as specified and directed by Engineer-in-Charge.
143Supply and fix in replacement of flame proof exhaust fan 300 mm sweep iron bodywith all accessories complete all as specified and directed by Engineer-in-Charge.
144S&F in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade,cross-sectional area 6 sqmm 2 coreall as specified and directed by Engineer-in-Charge.
145M&Lfor providingDisplay board of size 1m x 1m x1 cm madeup with acrylic sheetmaterial consisting of"PUMP HOUSE NO 1 & 2GE(AF) Faridabadand MES Logo" in Capital Letterat the Top complete with fixing arrangements to the wall complete all as specified and directed by Engineer-in-Charge.
146M&Lfor providingDisplay board of size 1m x 1m x1 cm madeup with acrylic sheetmaterial consisting of"Power House 11 KV GE (AF) Faridabad" in Capital Letterat the Top with fixing arrangements to the wall complete all as specified and directed by Engineer-in-Charge.
147S&F in replacement of PVC copper cable for submersible pump ofsize 6 Sqmm 3 core flatcomplete all as specified and directed by Engineer-in-Charge.
148M&L for rectification of leakage of UG water pipe lines of size 80 to 150 mm Bore of any description such as CI/DI/GIpipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material complete all as specified and directed by Engineer-in-Charge.
149All as per item No 148 above but but for size of 15 mm to50mm dia pipe line complete all as specified and directed by Engineer-in-Charge.
150M&L for rectification of leakage complaints of sluice valves by opening removing gland plate and pumping/taking water from water pit and proving gland packing and refitting by replacing worn out bolts,nuts and washers complete all as specified and directed by Engineer-in-Charge. Note: bolts,nuts and washers will be paid under relevant items of schedule
151M&L for Dewatering the existing U/G sump of 25000 Ltrs capacity and cleaning the internal surface of sump for removingscales, funges, mud and other foreign material ,scrubbing with water using wire brush and watering the surfaces with mixture of bleaching powder and water ,finally washing with fresh water and treating with one coat of lime wash to internal wall and bottom surfaces etccomplete for one time,writing in enamel paint note in block capital letter as cleaned on (date) and due date etc,height not less than 5 cm complete all as specified and directed by Engineer-in-Charge.
152Repair maintainance of oil cooled servo voltage stablizer of capacity400 to 630 KVA 3 phase by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizer,detecting of fault ,u/s component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts /component all as specified and directed. Note:- The replacement spare parts shall be measured and paid separately complete all as specified and directed by Engineer-in-Charge.
153Supply Only spare part of the Voltage stablizer 400/630 KVAcomplete all as specified and directed by Engineer-in-Charge as following:- RC Network
154AC Synchronous Motor 10 Kg
155Spring loaded finger
156Microproccessor Based eletronic control board
157Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but including ashlar facings, dressed stonework and precast concrete articlescomplete all as specified and directed by Engineer-in-Charge
158M&L for Brickwork with subclass "B" bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge
159All as per item No 158 above here in but except bricks complete all as specified and directed by Engineer-in-Charge
160M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge
161M&L for Cutting holes exc 400 sq cm but n exc 0.10 sqminto or through brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete complete all as specified and directed by Engineer-in-Charge
162M&L for making good in CM 1:4 under cills or over arches, lintels and bressummers. including allpinning when necessary complete all as specified and directed by Engineer-in-Charge
163Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge
164M&L, Rendering 15mm thick in CM 1:4 onof brick work or concrete surfacefinish ever and smooth (w/o using extra cement) incl WPC as per user manual at any height etc complete all as specified and directed by Engineer-in-Charge. (WPC will be measured and paid separately).
165Supply only Liquid water proofing compound complete all as specified and directed by Engineer-in-Charge
166M&L for Rendering 5 mm thick in cement and sand mortar 1:3 onother than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth on ceilings, complete all as specified and directed by Engineer-in-Charge
167M&L for rendering 15 mm thick cement plaster in CM 1:6 onbrick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
168M&L for 3mm thick wall care putty on wall complete all as specified and directed by Engineer-in-Charge.
169M&L for 3mm thick wall care putty on ceiling complete all as specified and directed by Engineer-in-Charge.
170M&L for Preparation of new plastered or concrete surfaces of walland applying two coats of cement base paint upto triple storey height, complete all as specified and directed by Engineer-in-Charge.
171M&L for Preparaing old surface (plastered or unplastered) by Washing, rubbing down and stopping of painted surfaces of walls and applying one coat of cement base paint, complete upto triple storey height, all as specified and as directed by Engineer-in-Charge
172M&L for Preparation of new plastered surfaces of walland applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed by Engineer-in-Charge.
173M&L for Preparaing old surface (plastered or unplastered) by Washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of oil bound distemper on walls, complete all as specified and as directed by Engineer-in-charge
174M&L for Preparaing old surface (plastered or unplastered) by Washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of oil bound distemper on ceilling surfaces, complete all as specified and as directed by Engineer-in-charge
175M&L for Preparaing new surface (plastered or unplastered) by Washing, rubbing down and stopping of distempered and applying 2 coat of white wash on ceiling, complete all as specified and directed by Engineer-in-Charge
176M&L for non skid ceramic tiles 7 to 8 mm thick any coloured/printed (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.18 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles, over 15 mm thick screed bed in cement mortar (1:4) in floors, incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed by Engineer-in-Charge
177M&L for Glazed ceramic tile 450 x 300 x 06-7mm thick (coloured)on vertical surfaces such aswall, dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10 mm thick screed bed in cement and sand mortar 1:4, and dismantlling of existing tiles complete all as specified and as directed by Engineer-in-Charge.
178Taking down and refixing of shuttersin same openingafter easing and adjusting of any description exc 1 sq. m and n exc 2 sq. m each including resecuring/changing of builders hardware complete all as specified and directed by Engineer-in-Charge
179M&L for 18 to 20 mm thick Granite (of any type) work(table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms, wash basin platformand like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed by Engineer-in-Charge Note :- 1. Contractor shall be bounded to carryout repair / maint upto G+3 storey building and the rate shall be deemed including scafolding / double scafolding, safety equipments and misc accessories.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail