Tender For Repair Maintenance Of Dg Sets Voltage Stabilizer And Controlling System Amf Panels Of Electric Panels Of Water Supply Installations Including Repair Maint Of Summer And Cooling Appliances And Related Works At Avn And Tanda Area At Akhnoor, akhnoor-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair Maintenance Of Dg Sets Voltage Stabilizer And Controlling System Amf Panels Of Electric Panels Of Water Supply Installations Including Repair Maint Of Summer And Cooling Appliances And Related Works At Avn And Tanda Area At Akhnoor. Submission Date for this Tender is 10-01-2023. Voltage Stabiliser Tenders in akhnoor Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

35257770
Corrigendum : Tender For Repair Maintenance Of Dg Sets Voltage Stabilizer And Controlling System Amf Panels Of Electric Panels Of Water Supply Installations Including Repair Maint Of Summer And Cooling Appliances And Related Works At Avn And Tanda Area At Akhnoor
Open Tender
Indian
Jammu And Kashmir
akhnoor
10-01-2023

Tender Details

Tender For Repair Maintenance Of Dg Sets Voltage Stabilizer And Controlling System Amf Panels Of Electric Panels Of Water Supply Installations Including Repair Maint Of Summer And Cooling Appliances And Related Works At Avn And Tanda Area At Akhnoor

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 99600.0 /-
Tender Value
INR 49.80 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINT OF DG SETS, VOLTAGE STABILIZER AND CONTROLLING SYSTEM (AMF PANELS) OF ELECTRIC PANELS OF WATER SUPPLY INSTALLATIONS INCLUDING REPAIR/MAINT OF SUMMER AND COOLING APPLIANCES AND RELATED WORKS AT AVN AND TANDA AREA AT AKHNOOR UNDER GE (N) AKHNOOR
Sl. No. Item Description
1Overhauling & servicing ofwindow /Split type AirConditioners up to 2 Ton capacity of any make and carry out of following tasks at different location of different establishment including taking down the AC (if required) from existing location, refixing / commissioning and testing the same after overhauling complete including the following :- (a) Inspection taking down, opening (dismantling) ,washing the condensor and cooling coil complete with acid/water as required and cleaning with air blower and testing complete (b) Checking / examine operation of condensor, blower motor, cooling coil and checking the air circulation to ensure complete movement of working part trouble free (c) Inspection of leakage in system and removal obstruction if any (d) Checking and correction earth continuity of electric items (e) Checking servicing thermostat and over load and other spares and test its functioning (f) Inspecting all electrical connection and remove if any defects (g) Checking servicing and greasing oiling of blower motor.(h) Top up Refrigerent gas if required. Note: Replacement of new parts/worn out parts in lieu of unserviceable/burn out part shall be measured and paid separately as supply only items of sch A.
2M&L for fan motor for AC ( window/split) capacity 1.5 Ton of approved make and required size to suit the existing AC incl taking out unserviceable fan motor all as specified and directed.
3M&L for fan motor for AC ( window/split) capacity 2 Ton of approved make and required size to suit the existing AC incl taking out unserviceable fan motor all as specified and directed.
4M&L for rewinding of Fan motor for AC ( window/Split ) of capacity 1.5/2 Ton with super enamelled copper wire of suitable guage and quantity, insulating material incl taking out burnt winding from existing AC all as specified and directed.
5M&L for air filter forAC ( split type) of capacity 1.5/2 Ton AC of existing make incl taking out unserviceable filter complete all as specified and directed.
6M&L for running capacitor of capacity 36 -56 MfdsuitableforAC ( windoe/split type) of capacity 1.5/2 Ton AC of existing make incl taking out unserviceable capacitor complete all as specified and directed.
7M&L for starting capacitor of capacity 80 -120 MfdsuitableforAC ( window/split type) of capacity 1.5/2 Ton AC of existing make incl taking out unserviceable capacitor complete all as specified and directed.
8M&L for running capacitor for fan Motor of capacity 4 -6 MfdsuitableforAC ( window/split type) of capacity 1.5/2 Ton AC of existing make incl taking out unserviceable capacitor complete all as specified and directed.
9M&L for starting relaysuitableforAC ( window/split type) of capacity 1.5/2 Ton AC of existing make incl taking out unserviceable relay complete all as specified and directed.
10Removing the burnt/defective sealed compressor unit of any type and any make from Air Conditioner window type up to 2.0 ton capacity by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor rotary unit of suitable make as existingby connecting suction and discharge lines with filling of refrigerant gas (in quated rate), welding/brazing work and tightening foundation nuts & bolts including etc all as specified and directed. Note :- (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b)New compressors will be purchased from authorised dealer only.
11Removing the burnt/defective sealed compressor unit of any type and any make from Air Conditioner split type up to 2.0 ton capacity by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed rotary compressorunit of suitable make as existingby connecting suction and discharge lines with filling of refrigerant gas (in quated rate), welding/brazing work and tightening foundation nuts & bolts including etc all as specified and directed. Note :- (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b)New compressors will be purchased from authorised dealer only.
12S & F in replacement of Sheet metal enclosure in/on wall with socket plug top and MCB single pole neutral enclsoure with 2 pin + earth plug and socket complete with one single pole MCB of 32 amps 230 volts of repturing capacity of 10 KA and making good the disturbed surface with existing colour matching complete. Make- Legrand / Havells / Schnider/HPL
13M&L in replacement of damaged copper tubing of dia 5/8 inch in Split Air conditioners fordischarge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
14M&L in replacement of damaged copper tubing of dia 3/8 inch in Split Air conditioners fordischarge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
15M&L in replacement of damaged copper tubing of dia 1/2 inch in Split Air conditioners fordischarge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
16M&L in replacement of damaged copper tubing of dia 1/4 inch in Split Air conditioners fordischarge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
17M&L in replacement of damaged insulation for copper tubing of split air conditioners complete all as directed
18Repair to Air conditioner window type/Split type up to 2.0 ton capacity by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuming the system and charging of gas (M410a/R134a/R22/R32) as existing and testing etc complete all as specified & directed. Note : (a) Drier capillary and copper tubing are inclusive in quoted rate.(b) Contractor should be responsible if leakage of refrigerent gasafter repair within one year of completing job and shall be made good without extra payment.
19Supply and Fix in replacement of blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type upto 2.0 ton capacity as per existing model complete all as directed and specified.
20Supply and Fix in replacement ofblower Motor 0.2/0.25 HP for Air conditioner split type of capacity 1.5 ton/2.0 ton/3.0 ton/4.0 ton as per existing model completeas directed and specified.
21Supply and Fix in replacement ofPrinted Circuit Board as per existing model to repair to split type/window type Air Conditioners of any make and type of any capacityany complete all as directed Make- Voltas/Carrier/toshiba.
22Supply and Fix in replacement ofwireless remote control unit for split/window type airconditioner as per existing model complete all as directed. Make Carrier (Duracool)/Carrier (X power gold)/LG/VOLTAS
23M&L for opening of the automatic voltage stabilizer of capacity upto 8 KVA for repair, detection of fault and its repair, cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts, soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M " all as directed of any make for the following:- Note : (a) Replacement of new parts/worn out parts in lieu of unserviceable/ burn out part shall be measured and paid separately as supply only. (b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM shall be deemed to be included in quoted unit rate.
24Supply only the spare parts suitable for automatic voltage stabilizer of any make and capacity complete.
25(i) Volt meter (0-300 volts)
26(ii) Control relay
27(iii) IC controlled circuit for 5KVA
28(iv) IC controlled circuit for 8 KVA
29(v) Control transformer
30(vi) Main transformer for 5 KVA
31(vii) Main transformerfor 8 KVA
32M&L for Shifting and refixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the systemas existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of split AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas,Insulation and LDPE pipe are inclusive in quoted rate.(c)making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregade, 15mm thick rendereing in cement mortar (1:3) good the disturbed surface with existing colour matching are inclusive in quoted rate.
33M&L for Shifting and refixing of window ACof any make and any type after servicing and charging of gas (M410a/R134a/R-22/R32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the systemas existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of window AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas and LDPE pipe are inclusive in quoted rate.(c)Making hole on wall andgood the disturbed surface with existing colour matching are inclusive in quoted rate.
34Servicing of complete desert cooler comprising oiling, greasing of all rotatry, moveable parts, taking down unserviceable parts for necessary repairs/replacement, assembling of desert cooler with old serviceable parts and replacement of unserviceable parts with new serviceable parts all as directed by Engr-in-Charge. Note :- i)Parts required to be replaced shall be replaced and paid separately as " supply only "against relevant item (s) of this schedule. However, labour element involved in replacement is included in unit rate quoted against this item. ii)Any minor parts, PVC ellbows, connectors, distributor caps, PVC flexible pipe, wire mesh, rubber pasds/ repairs involved to make the desert cooler completely functional even if not notified by Engr-in-Charge shall be carried out by the contractor without any extra cost to the department.
35Supply only the following items (PROVISIONAL) to incorporate (i) Grass wool pads (set of three)
36(ii) Switch piano single pole one way 6 Amps.
37(iii)Indicator lamp 6 Amps.
38(iv)Selector switch for speed controller of motor (three steps).
39(v) Submersible switch for speed controller of motor (three steps).
40(vi) Front grill for desert cooler Make- Khaitan, Crompton Greaves, Bajaj, Havells/ As per site.
41(vii)Desert cooler fan motor with fan complete Make- Khaitan, Crompton Greaves, Bajaj, Havells.
42Taking down sealed compressor of 165ltr/175 ltr capacity of refrigerator of any make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity, connecting sealed unit and discharge pipe with gas welding and soldering rod complete all as specified and as directed.
43Taking down sealed compressor of 286ltr/310/300 ltr capacity of refrigerator of any make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity, connecting sealed unit and discharge pipe with gas welding and soldering rod complete all as specified and as directed.
44M&L in repairs thermostat switch for refrigerator of any capacity complete all as specified and directed.
45M&L for charging of refrigerator suitable gas after vacuming/pressure and leaking including flushing the system in the refrigerator of any make and 165 ltr capacity
46M&L for charging of refrigerator suitable gas after vacuming/pressure and leaking including flushing the system in the refrigerator of any make and 230/286/300/310ltr capacity
47Taking down sealed compressor of water cooler any make of capacity 40/80 Ltrs and supply and fixing in replacement sealed compressor and connecting up suction and discharge copper pipe with gas welding pressure testing of leakage rectification, vaccumising and charging the refrigerant gas , testing , commissioning complete all as specified
48Taking down sealed compressor of water cooler any make of capacity 60/120 Ltrs and supply and fixing in replacement sealed compressor and connecting up suction and discharge copper pipe with gas welding pressure testing of leakage rectification, vaccumising and charging the refrigerant gas , testing , commissioning complete all as specified
49M&L in replacement condensor fan motor 1/35 HP 230 Volt AC single phase suitable for water cooler all as specified and directed.
50M&L in replacement condensor fan motor 1/83 HP 230 Volt AC single phase suitable for water cooler all as specified and directed.
51Detecting the gas leakage , rectifying the defects, vacumising and charging fresh refrigerant gas and commissioning and testing the water cooler 40/80 and 60/120 ltrs complete all as specified and as directed.
52M&L for preparation of old painted steel surface of water cooler by complete scraping and applying one coat of synthetic enamel paint by spraying on outer surface as per existing colour and black on bottom portion such as compressor, bottom frame etc of 40/80 ltrs capacity all as specified and directed.
53M&L for preparation of old painted steel surface of water cooler by complete scraping and applying one coat of synthetic enamel paint by spraying on outer surface as per existing colour and black on bottom portion such as compressor, bottom frame etc of 60/120 ltrs capacity all as specified and directed.
54Submain wiring with two single core (FLRS) PVC insulated flexible copper conductor cable of size 6 Sqmm (multistranded) drawn into and including PVC conduit, 2 mm thickness with fitting and accessories fixed on walls/ceiings includingcutting chasses in bricks walls and making good the chased walls with CM 1:3 and finishing the surfaces to match with existing surfaces including 4.0 Sqmm PVC insulated copper conductor cable as earth wire drawn into conduit and connecting to common earth or earth dolly, including fixing hooks, clamps etc, including taking down unserviceable materials from site for carring to store all as directed by Engr-in-Charge. (Note : Two runs of copper cable, one run of earth wire, one run of PVC conduit shall be measured as one unit.) Make Havells, polycab , Gloster
55Preparation of old painted surfaces of desert cooler body complete and spray painting with one coat of red oxide from inside and one coat of synthetic enameal paint as approved by Engr-in-Charge and writing MES No as directed on Desert Cooler Body.
56M&L for casing capping ISI marked 40mm size all as specified and directed Make Anchor
57M&L for casing capping ISI marked 25mm size all as specified and directed Make Anchor
58Servicing the water cooler of any make including cleaning the water tank, condensor and the side body by washing, rubbing down including removing all the dust, dirt complete all as directed.
59Supply and charging of refrigerant gas R22 complete all as directed.
60Supply and charging the Refrigerant Gas R- 134a/ R-32 complete all as directed.
61Taking down sealed compressor of upto 320ltr capacity of deep freezer of any make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity, connecting sealed unit and discharge pipe with gas welding and soldering rod complete all as specified and as directed.
62Taking down sealed compressor of 400 to 500ltr capacity ofdeep freezer of any make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity, connecting sealed unit and discharge pipe with gas welding and soldering rod complete all as specified and as directed.
63Servicing the deep freezer of any make including cleaning the water tank, condensor and the side body by washing, rubbing down including removing all the dust, dirt complete all as directed.
64Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified anddirected.
65Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 1.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:- Make of Cables Havells, KEI, Grandlay (Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used of same make/brand onlyand shall be deemed in to included in quoted rate only.)
66(i) One light point/fan /bell pointcontrolled by one switch.
67(ii) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
68(iii) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
69Materialand labour for point wiring complete with 2.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 2.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:- Make of Cables Havells, KEI,Grandlay (Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used of same make/brand onlyand shall be deemed in to included in quoted rate only.)
70(i)One 15 amps power socket outlet point controlled by one 16 amps switchon independent board.
71Supply & fixing modular type switch 6 Amps, single pole, 1way,1 module,240V, ISI Markedcomplete all as specified and directed. Make Crabtree,Havells,polycab
72Supply & fixing modular type switch 16 Amps, single pole,1 way,1 module,240V, ISI Marked Complete all as specified and directed.Make crabtree,Havells,polycab
73Supply & fixing modular type socket shuttered type 6 Amps- 2/3 Pin combined 2 module,240V,ACISI Marked Complete all as specified and directed. Make crabtree,Havells,polycab
74Supply & fixing modular type socket 6 A/16 Amps -2/3 Pin combined shuttered socket 2 module 240V ACISI MarkedComplete all as specified and directed Make Crabtree, Havells,polycab
75Supply, Installation and Fixing AMF PANEL for 62.5KVA D.G Set shall be made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54in accordance with IEC 60529 and Color code RAL 7032 completely dyedin mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal sizeshould be not less than 590mm x 800mm x 250 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. The Panel box shall have shall be equipped with GRP handle lock with THREE point locking mechanism and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Panel Stand Angle Iron of 50x50x5mm and Copper Bus-bar with Heat Shrinkable Sleeves of capacity 150 Amp, TPN. Start/Stop Push Buttons, Auto/Manual Selector Switches, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed :-Make-Hensel/Rittal/Emitter/Schneider INCOMMING :-
76i). MCCB 100Amp 4 P 25 KA with Thermal and magnetic released with spreader links - 2 Nos ( Main & D.G )
77ii). 160 Amp Contactors MCX 32 - 2 Nos
78iii). LED indicator R/Y/B- 3 Sets
79iv). Multi-functional Meter ( Volt,Amp,frequency ) with 3 Nos CT Coils 100/5A - 1 No
80v). Battery Charger 12V - 10Amp - 1 No
81vi). Control MCB SP 2Amp- 6 Nos
82vii). SM 500 Relay - 2 Nos
83viii). On Delay Tmer - 2 Nos
84ix). 8 Pin Relay - 1 Nos
85Note :- AMF Panel with Complete all accessories for Command to D.G Auto Start/Stop and convert in D.G and Electricity.
86Supply, Installation and Fixing AMF PANEL for 160KVA D.G Set shall be made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54in accordance with IEC 60529 and Color code RAL 7032 completely dyedin mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal sizeshould be not less than 590mm x 800mm x 250 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. The Panel box shall have shall be equipped with GRP handle lock with THREE point locking mechanism and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Panel Stand Angle Iron of 50x50x5mm and Copper Bus-bar with Heat Shrinkable Sleeves of capacity 400 Amp, TPN. Start/Stop Push Buttons, Auto/Manual Selector Switches, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed :-Make-Hensel/Rittal/Emitter/Schneider INCOMMING :-
87i). MCCB 400Amp 4 P 25 KA with Thermal and magnetic released with spreader links - 2 Nos ( Main & D.G )
88ii). 400 Amp Contactors MCX 43 - 2 Nos
89iii). LED indicator R/Y/B- 3 Sets
90iv). Multi-functional Meter ( Volt,Amp,frequency ) with 3 Nos CT Coils 400/5A - 1 No
91v). Battery Charger 12V - 10Amp - 1 No
92vi). Control MCB SP 2Amp- 6 Nos
93vii). SM 500 Relay - 2 Nos
94viii). On Delay Tmer - 2 Nos
95ix). 8 Pin Relay - 1 Nos
96Note :- AMF Panel with Complete all accessories for Command to D.G Auto Start/Stop and convert in D.G and Electricity.
97Supply, Installation and Fixing AMF PANEL for 125KVA D.G Set shall be made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54in accordance with IEC 60529 and Color code RAL 7032 completely dyedin mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal sizeshould be not less than 590mm x 800mm x 250 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. The Panel box shall have shall be equipped with GRP handle lock with THREE point locking mechanism and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Panel Stand Angle Iron of 50x50x5mm and Copper Bus-bar with Heat Shrinkable Sleeves of capacity 300 Amp, TPN. Start/Stop Push Buttons, Auto/Manual Selector Switches, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed :-Make-Hensel/Rittal/Emitter/Schneider INCOMMING :-
98i). MCCB 300Amp 4 P 25 KA with Thermal and magnetic released with spreader links - 2 Nos ( Main & D.G )
99ii). 300 Amp Contactors MCX 41 - 2 Nos
100iii). LED indicator R/Y/B- 3 Sets
101iv). Multi-functional Meter ( Volt,Amp,frequency ) with 3 Nos CT Coils 300/5A - 1 No
102v). Battery Charger 12V - 10Amp - 1 No
103vi). Control MCB SP 2Amp- 6 Nos
104vii). SM 500 Relay - 2 Nos
105viii). On Delay Tmer - 2 Nos
106ix). 8 Pin Relay - 1 Nos
107Note :- AMF Panel with Complete all accessories for Command to D.G Auto Start/Stop and convert in D.G and Electricity.
108Earthing complete with galvanised steel earth plate electrode 60cmx60cmx3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground) with top edge of plate not less than 1.5m belwo bnormal ground level connecting to the GI erthing strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron and GI Strip 32x6mm protected by provision of GI Light grade pipe of 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 40mm grade crushed stone aggregrate iwh 40mm thick cover of RCC (1:2:4) raniforced with PM (weight not less than 4Kg/sqmm) and frame of angle iron 25x25x6mm with lugs 02 nos and 6mm dia MS bars handle made to shape, GI Light ggrade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge for earth platem common salt and charcoal filling, test point made out of 75x50x6mm phodphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hand/ dense soil rning filling in andremoval of surplus soil to a distance not exceeding 50m all as per electrical plate nmp 5 of SSR 1991 Pt-I and connecting to earh test point incl testing on completion.
109Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 95 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells/ Gloster/ Polycab
110Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 120 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Havells/ Gloster/ Polycab
111Excavation in tranches not exceeding1.5 m wideand not exceeding 1.5 m deep for foundationof laying cable including gettingout in soft/loosesoil complete all as specified and directed.
112Returning filling in including spreadingwateringand well ramming in layers not exc25cmcomplete all as specifed .
113Removing surplus soilto distance not exceeding50 m and depositing where directed at a level notexceeding 1.5 m above the starting pointcomplete all asspecifiedand directed .
114M & L for protection to cable with one layer of brick laid flat across the cable using all size sub class "B" Bricks.
115Sand cushioning to under ground electric cables including watering and consolidation all as per clause 19.75 of SSR Part-I
116Supply and installation in repairs, commissioning and testing Polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of ASTA CPRI TEST REPORT IN POLYCARBONATE only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing]. Make-Hensel/Rittal/Emitter/Schneider
117INCOMER: i. Main MCCB 400A 4Pole Breaking Capacity 36KA adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle– 1 No. ii. Digital VAF Meter with Volt,Amp, Frequency – 1 Nos iii. LED Indicator Lamp R,Y,B – 3 Nos iv. CT coils 400/5A – 3 Nos v.  Control Fuse – 3 Nos OUTGOINGS: i.  MCCB 250A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos. ii.  MCCB 125A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos. iii. MCCB 100A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos. iv.MCCB 63A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos.
118Supply and installation in repairs, commissioning and testing Polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of ASTA CPRI TEST REPORT IN POLYCARBONATE only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing]. Make-Hensel/Rittal/Emitter/Schneider
119INCOMER:
120Main MCCB 250A 4Pole Breaking Capacity 36KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle– 1 No.
121Digital VAF Meter with Volt,Amp, Frequency – 1 No
122LED Indicator Lamp R,Y,B – 3 Nos
123CT coils 250/5A – 3 Nos
124Control Fuse – 3 NoS
125OUTGOINGS :-
126MCCB 160A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos.
127MCCB 125A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos.
128MCCB 100A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos.
129MCCB 63A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos.
130Supply and installation in repairs, commissioning and testing Polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of ASTA CPRI TEST REPORT IN POLYCARBONATE only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing]. Make-Hensel/Rittal/Emitter/Schneider
131INCOMER:
132Main MCCB 160A 4Pole Breaking Capacity 36KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle– 1 No.
133Digital VAF Meter with Volt,Amp, Frequency – 1 No
134LED Indicator Lamp R,Y,B – 3 Nos
135CT coils 160/5A – 3 Nos
136Control Fuse – 3 Nos
137Outgoings
138MCCB 125A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos.
139MCCB 100A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 2 Nos.
140MCCB 63A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 2 Nos.
141Surface excavation n exc 30cm deep and averaging 15 cm any type of soil all as specified and directed.
142M&L for rolling and consolidating of soling of broken bouldersnot exceeding 15cm thick with power roller exc 5 tonne and nexc 8 Tonne.
143M&L for cement concrete in foundation, filling and mass concrete type D2 1:4:8 40 mm graded (100mm) all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail