Tender For Improvement Of Wiring And Other Electrical Installations In Various Deptt. Including Laundry Room, Kitchen Area, Cssd , Radiology, Mro Building And Opd At Kasturba Hospital Under City S.P. Zone, Delhi-Delhi

Municipal Corporation has published Tender For Improvement Of Wiring And Other Electrical Installations In Various Deptt. Including Laundry Room, Kitchen Area, Cssd , Radiology, Mro Building And Opd At Kasturba Hospital Under City S.P. Zone. Submission Date for this Tender is 21-12-2022. Brushes Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35255895
Tender For Improvement Of Wiring And Other Electrical Installations In Various Deptt. Including Laundry Room, Kitchen Area, Cssd , Radiology, Mro Building And Opd At Kasturba Hospital Under City S.P. Zone
Tender
Indian
Delhi
Delhi
21-12-2022

Tender Details

Improvement Of Wiring And Other Electrical Installations In Various Deptt. Including Laundry Room, Kitchen Area, Cssd , Radiology, Mro Building And Opd At Kasturba Hospital Under City S.P. Zone - Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size M.S. Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C N 2 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 3 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 4 Supplying And Fixing Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required.180 Mm X 100 Mm X 60 Mm Deep 5 Supplying And Fixing Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required.200 Mm X 250 Mm X 60 Mm Deep 6 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.5 / 6 Amps Switch 7 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.15 / 16 Amp Switch 8 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 9 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 10 Supplying And Fixing Metal Box Of 180Mm X 100Mm X 60Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Socket Outlet And 15 / 16 Amps Piano Type Switch, Connection, Painting Etc. As Required. 11 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep 12 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.150 Amp, 16Ka, Tpmccb 13 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.250 Amp, 25 Ka, Tpmccb 14 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.400 Amp, 35 Ka, Tpmccb 15 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.630 Amp, 50 Ka, Tpmccb 16 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator8 Way, Double Door 17 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator12 Way, Double Door 18 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting McbS ( But Without McbS And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 4 Way ( 4 + 12 ) , Double Door 19 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 20 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps 21 Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.100 Amps 22 Supplying And Fixing 20 Amps, 240 Volts, Spn Industrial Type, Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Along With 20 Amps C Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 23 Supplying And Installing Following Size Of Perforated Pre-Painted M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.375 Mm Width X 50 Mm Depth X 2.0 Mm Thickness 24 Supplying And Installing Following Size Of Perforated Pre-Painted M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.300 Mm Width X 62.5 Mm Depth X 2.0 Mm Thickness 25 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required 26 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Refilling Etc. As Required. 27 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required.Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 28 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required.Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) 29 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required.Above 95 Sq. Mm And Upto 185 Sq. Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 30 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374- 2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 31 Supply Of 18 ( 450Mm ) Sweep 1400 Rpm Heavy Duty Exaust Fan Complete With Arms, Ring, Blade Etc , Isi Marked Working On 220 / 240 V Ac Supply As Reqd. 32 Supply Of Following Size 1400 Rpm Heavy Duty Exaust Fan Complete With Ring, Blade Etc As Required. Isi Marked. 15 ( 380 Mm ) 33 Supply & Fixing Of 400 Mm Wall Fans Complete With Blades , Jaal Workable On 220 / 240 V Ac Supply Etc As Reqd. 34 S / I / T / C Of Led Tube Type Luminaire 20 W Rating Complete With Extruded Aluminium Batten Pre-Wired With High Efficient LedS With The Following:- A ) Total System Wattage 20 Watt + / - 5% B ) Luminous Efficacy Lumens / Watt>=95 C ) Power Factor> 0.95 35 Supply Of Xlpe Insulated Pvc Sheathed Ai. Conductor Armoured Cable 1.1Kv Grade Confrormin To Is-7098 Of Following Size A ) 4 Core 25 Sqmm 36 Supply Of Xlpe Insulated Pvc Sheathed Ai. Conductor Armoured Cable 1.1Kv Grade Confrormin To Is-7098 Of Following Size A ) 4 Core 50 Sqmm 37 Supply Of Xlpe Insulated Pvc Sheathed Ai. Conductor Armoured Cable 1.1Kv Grade Confrormin To Is-7098 Of Following Size A ) 3.5 Core 120 Sqmm 38 Fabrication, Supply, Installation, Testing & Commisioning Of 15 Cm To 30 Cms Deep Cubical Panel Type Panel Board Made Out Of 1.6 Mm Thick Ms Sheet Equiped With Neutral Link Aluminium Bus Bar 315 Amp Capacity Suitable In All Compartmeent Accommodate Accessries / Switch Gear Including Interconnection With Solid Alum, Bolt Of All Switch Gear Termination On Both Side Incoming / Outgoing Complete Two Coats Of Approved Quality Color Of Enameled Paint, Earthing Etc As Reqd.

Key Value

Document Fees
INR 500 /-
EMD
INR 32200.0 /-
Tender Value
INR 16.05 Lakhs /-