Construction Of Petrol Pump At Gopeshwar Distt. Chamoli, Uttarakhand, chamoli-Uttarakhand

Garhwal Mandal Vikas Nigam Ltd-GMVN has published Construction Of Petrol Pump At Gopeshwar Distt. Chamoli, Uttarakhand. Submission Date for this Tender is 30-12-2022. Civil Work Tenders in chamoli Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

35251461
Construction Of Petrol Pump At Gopeshwar Distt. Chamoli, Uttarakhand
Open Tender
Indian
Uttarakhand
chamoli
30-12-2022

Tender Details

Construction Of Petrol Pump At Gopeshwar Distt. Chamoli, Uttarakhand

Key Value

Document Fees
INR 4720 /-
EMD
INR 273000.0 /-
Tender Value
INR 1.36 Crore /-

BOQ Items

Name of Work: CONSTRUCTION OF PETROL PUMP AT GOPESHWAR DISTT. CHAMOLI
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
3Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
4Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
5Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
6Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
7Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
8Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
9Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
10Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
11Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
12Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
13Providing and spreading RBM i.e., River Bed Material (treated as granular sub-base /base/surface course material) in uniform layers with motor grader on prepared surface with rotavator and compacting with smooth wheeled roller to achieve the desired density.
14Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
1520 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
16Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
17Providing and laying 60 mm thick faciory made cement concrete interlocking paverblock of M -30 grade made by block making machine with strong vibratorycompaction, of approved size, design & shape, laid in required colour and patternover and including 50mm thick compacted bed of coarse sand, filling the jointswith line sand etc. all complete as per the direction of Engineer-in-charge.
18Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
19Providing and laying at or near ground level factory made kerb stone of M-25grade cement concrete in position to the required line, level and curvature, jointedwith cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to morethan 5mm), including making drainage opening wherever required complete etc.as per direction of Engineer-in-charge (length of finished kerb edging shall bemeasured for payment). (Precast C.C. kerb stone shall be approved by Engineerin-charge).
20Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
216 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
2212 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
23Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (basic rate of tile Rs 212/sqmt)
24Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
25Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. - Size of Tile 600x600 mm
26Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm
27Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
28Finishing walls with Acrylic Smooth exterior paint of required shade- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
29Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
30Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood
31Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
32Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Second class teak wood
33Providing and fixing bright finished brass handles with screws etc. complete: 125 mm
34Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 200x10 mm
35Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
36Providing and fixing bright finished brass night latch of approved quality including necessary screws etc. complete.
37Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
38Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortarwhich will be paid for separately (for the purpose of measurement the entire treated surface will be measured) Roof
39Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge
40Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4stone aggregate 10 mm and down gauge), including finishing with cement mortar1:3 (1 cement : 3 fine sand) as per standard design :
41Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover
42Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).
43P/f of S.S. Door handle300 mm complete in all respect
44P/f of lock For toughned Glass complete in all respect.
45Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 20 mm dia
46Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 20 mm dia nominal bore
47Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore
48Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore
49Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
50Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.20 mm nominal bore, 120 mm long, weighing not less than 198 gms
51Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter
52Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
53Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler75 mm
54Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler110 mm
55Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° - 75 mm bend
56Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° -110 mm bend
57Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
58Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
59Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
60Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
61Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms
62Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
63Providing and fixing white vitreous china flat back half stall urinal of size Single half stall urinal with 5 litre P.V.C. automatic flushing cistern.
64Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc.Complete as per standard design ine Inside dimensions 455x610 mm and 45 cm deep for single pipe line
65Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc.Complete as per standard design ine Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets
66Providing and fixing Bowl With Cistern For Coupled WC With UF Soft Close Slim Seat Cover, Hinges, Dual Flush Cistern Fitting, Fixing Accessories And Accessories Set, Size: 375x650x800 mm, P Trap- 180 mm model No ARS-WHT-39751P180UFSMZ
67TABLE TOP BASIN ROUND SHAPE-RIM, TABLE TOP BASIN- SIZE480X480X135 (Jaquar make) model -OPS WHT- 1590IN,
68Providing and fixing of 1000.00 Ltr Capacity Bio Digester Tank With Anaculam Complete in all respect
69Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
70Providing & fixing false ceiling system of Trac 150 F exterior grade or approved equivalent of 0.5mm thick galvanised steel with stove enameled coil coated finish inter locking ceiling panels, carriers, suspension system and edge closure as per the following specification. Supplying and installation of exterior grade 150 F ceiling system comprising of 150 mm x 17 mm deep panels roll formed out of 0.5 mm galvanised steel with stove enameled coil coated finish. The panels shall be pre-treated and coil coated on one side in manufacturers standard colour shades as approved by the Architect/ Engineer in charge. The rear side of the panel shall be given a coat of primer and a wash coat while the finished side shall be given a coat of primer and finish colour coat in polyster paint for a min. dry film thickness of 20 microns, fixed on to the roll formed carriers 34.5 mm x 488 mm deep out of 6 mm thick Galvanised steed with prongs to hold panels in the module of 150 mm at maximum 1.2 mts. C/C. The carriers to be suspended from roof truss by rigid suspension angles as per manufacturer"s recommendation. Panels shall be supplied in custom length upto maximum of 5 mts. Job also includes providing ceiling flashing using factory formed 0.5 mm thick Polyster coated galvanised steel material. Rate shall be including providing flashing to cover gap if any between illuminated banding and false ceiling.
7180 W LED Fitting as mentioned in IS standards IS 16101 to 16107: Supply and fixing of 80 W LED housed by Single piece Pressure Die Cast Aluminum body, recess mountable fitting with guaranteed burning hours of 50000 .Make lips/Havells/Bajaj/Wipro/Osram/ Crompton/GE/Bever Innovations. IP Protection of minimum IP 65 and above, suitable for canopy lighting at retail outlets (Petrol station) .The bidder should submit copy of certified photometric report as per IESNA LM-79(Approved method for the Electrical and Photometric Measurements of Solid-State Lighting Products) from a UL/ ERTL /ERDA or any NABL accredited laboratory to validate the photometric claims as & when asked by HPC. A minimum 3 years warranty from manufacturing defects for the luminaire by manufacturer.i) With high lumen efficacy LEDs from CREE, Seoul Semi-Conductor, Lumiled Philips, Osram, Nichia (Japan), Tridonic (Austria), GE and Bridgelux .Efficiency of more than 90 lumens per watt . LEDs used in the fixture should be from the same bin and certified as per LM-80 (IESNA: Approved Method for Measuring Lumen Maintenance of LED Light Sources and LED lumen depreciation time to L70 based on LM-80 data). by any UL/ ERTL /ERDA or any NABL accredited laboratory to validate the photometric claims as & when asked by HPC. ii) Bottom open able for easy maintenance.iii)High Quality Polycarbonate Opal Diffuser for Optimum uniformity and Glare free light output. iv) General electrical protection against High Voltage and Surges up to3 KV v) Power factor > 0.95vi) Range allowed for total system wattage 80 W with +2W or -2W vii) Driver Operating Voltage Range: 140 V- 270 V viii) Operating Temperature 0 to +45 Deg Centigrade viii) CRI more than 70.ix) Colour temperature5650K±500K (to be mentioned in LM 79 certificate) x)Wide beam angle for spread of light 120 degrees or morexi)Luminaire Performance Complies to IS10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529, ROHS
72Providing and fixing 20 SWGthick Aluminium SheetGuttersof required shape in slope with 40 mm x 3 mm MS. Brackets at 1000 mm maximum spacing and 8 mm dia G.I. J or L hooks, boltsand nuts, GI Limpet and bitumen washers, providing nut bolt joint,sealing the joints with silicon sealant testing the gutter for leakage by filling water etc.Complete.(Refer attached Drawing)
73Supply and fixing Clippon Roofing System: Roofing base material should be of cold rolled steel of 0.55 mm thick and conform to ASTM:A 446 having yield stress of 275 MPA . The coating should be Aluminum and Zinc alloy comprising 55% Al , 43.5 Zinc & 1.5 % Silicon , as per ASTM :A 792 . The coating mass should not be less than 150 Gms per SqM (total of both sides). For, bare galvalume, TCT should not be less than 0.55 mm . Sheets shall have approved side laps with top sheets facing away from the prevailing weather. Necessary profiled filler box should be provided at higher level of roof sheeting and at valley gutter to ensure water tightness in the profiled gaps . The fixing of roofing shall be done in such a manner that the roof is not drilled / punctured for fixing with the purlins. Refer to the approved makes given in the Attachment. Flashings, Cappings and trims: These shall be formed out of same substrates as that of the roofing sheets and shall be supplied in standard lengths of 2.5 M in the required shapes and girths and fixed by means of hex-head mechanically galvanized stitching screws. Silicon sealant non-hardening neutral cure type shall be applied at all laps to avoid water seepage.
74Supplying and fixing 20 SWG GI sheet facia including painting with one coat of zinc chromate primer and two coats of 1 st quality synthetic enamel paint on front side . Necessary facia framework for fastening the sheet to the canopy securely shall be paid separately.
75S/ Laying of 3 Cx 1.5 Sqmm Copper conductor cable complete in all respect.
76Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
77LPACCMOD S/F Light plug point modular type accesorries : each supplying and fixing suitable size GI box with modular plae and cover in front on surface and recess , including providing and fixing 3 pin 5/6 amps modular sockets outlet and 5/6 amps modular socket outlet and 5/6 amps modular switch, connecton ,painting etc. as required .(for light plugs to be used in non residentials buildings)
78PPACCMOD S/F power plug point modular type accessories : each supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular sockets outlet and 15/16 amps modular switch, connecton, painting etc. as required
79Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
80Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
81S/F TP MCB DB: Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phoshatized and powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)
82S/F TP MCB isolator: Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required.
83S/F "B" series, SP MCB Supplying and fixing 5 amps to 32 amps rating, 240 volts, "B" series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required.
84Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. -5/6 A switch
85Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. -3 pin 5/6 A socket outlet
86Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. -3 Module (100mmX75mm)
87Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required -40mm
88G.I earth plate elctrode:Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. including charcoal or coke for G.I. or copper plate earth electrode as required.and saltas required
89S/L SWG GI wire in ground: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required
90Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. 7.3.1 Upto 35 sq. mm-Upto 35 sq.
91Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 11.3.1 Above 4.5 metre and upto 6.5 metre. -Above 4.5 metre and upto 6.5 metre
92Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. -32 mm dia metre
93Suplly of PVC Insulated Alimnium XLPE Armourdcable 10sq. mm 4 core complete in all respect
94Supply of 6 mtr galanized octagoanal pole with base plate 200x200x12 top 70 mm & bottom 130mm mae up of 3 mm thik suitable for max wind speed upto 160 km .ihr
95Supply / fixing of factory febricated energy saving environment friendly Long flood light Exclusive innovation die cast aluminium housing with Toughened gladss and high power LED and secoundary Lenses with IP66 Protection systerm efficiency upto 110 LPW option for 3000K and impact resistance of 1K07 10kv built in surge protection Device complete Light Mount on high mast Light pole making hole on breaket with Nut Bolt complete in all respect.
96Supply/ Fixing of floor / wall mounted Pannel Board of suitable size with following accessaries incomming 100A 415 v 25KA MCCB-1no, outgoing 63A 415V 25KA MCCB -3NOS , 63A 415V 4Pole Isolator -4 Nos , measuring instument(ameter , voltmeter , frequency reader etc) , changeover switch 100A415V -1Nos .complete in all respect
97WGSTLMOD point wiring in pvc conduit , with modular type switch : wiring for light / fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor core cable im surface recessed pvc conduit with modular switch , modular plate , suitable GF box abd earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required.
98Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. -2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
99Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. -2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
100S/F brass holder Supplying and flxing brass batten/angle holder including connection etc. as required.
101Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (Butwithout MCB/RCCB/Isolator -8way , Double door
102Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required -63A
103Supplying and fixingf of decorative LEDBatten tube light fiting 20W , 4 feet complete with making connection and complite with all respect directed /approved by E/I
104S/F ofExhaust fan 230mm krypton HS Mtgray EF as approved by E/I complete with making connection in all respect . Including GSt, Cartage Labour Charges.
105S/F of ceiling Fan 1200mm(48") as approved by E/I ---complete in all resepct.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail