Tender For City Beautification Works At Jaisalmer - Rebid, jaisalmer-Rajasthan

Rajasthan Urban Infrastructure Development Project-RUIDP has published Tender For City Beautification Works At Jaisalmer - Rebid. Submission Date for this Tender is 13-01-2023. Civil Work Tenders in jaisalmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

35240713
Tender For City Beautification Works At Jaisalmer - Rebid
Open Tender
Indian
Rajasthan
jaisalmer
13-01-2023

Tender Details

Tender For City Beautification Works At Jaisalmer - Rebid

Key Value

Document Fees
INR 10000 /-
EMD
INR 2000000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: City Beautification works at Jaisalmer- Rebid
Sl. No. Item Description
1Earth Work
2Clearing Grass and Removal of Rubbish (Maximum 150mm) by manual means and disposal at a lead of 50 metres as per MoRT&H specification clause 201.
3Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m
4Earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per MoRT&H specification clause 301.
5Construction of embankment with approved material obtained from borrow pit with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 tonne to meet requirement of table 300-2 including cost of compensation for earth taken from private land complete as per MoRT&H specification clause 305. (Lead taken upto 5 km)
6Providing, laying and spreading of granular sub-base by providing coarse graded Material (Table 400-2), spreading in uniform layers with motor grader on prepared surface, mixing BY MIX IN PLACE METHOD with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion. Grading - III Material. (parking area,mud track, 6.5m walkway track)
7Providing, laying, spreading (with paver finisher only) and compacting wet mix macadam (WMM) base course comprising of graded stone aggregate and granular material conforming to MORT&H specifications (Table 400-II) in layers of equal compacted thickness each consolidated, including pre-mixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub-base/ base course and compacting with power vibratory-roller to achieve the desired density complete as per MoRT&H specification clause - 406 including all material, labour, machinery, lighting, guarding and maintenance of diversion. (parking area,mud track, 6.5m walkway track)
8Filling with locally available duns sandat all levels including dressing complete including cost of sand.(mud track)
9Concrete Work
10Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size).
11Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) (electric pole, rcc rtaining wall, fauntain)
12Formwork
13Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :
14Foundations, footings, bases of columns, etc. for mass concrete.
15Steel Reinforcement
16Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars
17Waterproofing Work
18Providing and laying in situ seven course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 100 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand) and finished neat which shall be paid for separately.
19Stone Masonry / Stone Soling
20Random rubble masonry with hard stone in foundation and plinth :
21Cement mortar 1:6 (1 cement : 6 coarse sand)
22Coursed rubble masonry (first sort) with hard stone in foundation and plinth with : (stone masonary above road level)
23Fine dressing of ashlar stone work (payable on Executive Engineer"s test checking):(A) White Ashlar two line (stone masonary above road level)
24Supplying and fixing Soorsagar Bhura or Equivalent ashlar sills, lintels and dassa, bearing, bed & top surface made perfenctly even, jambs, skirting steps etc. rough dressed:Upto 15 cm. thick (kerb stone)
25Supplying and fixing Jaisalmer stone fine dressed and ornamental cut work upto half depth complete.(signage stone and entrance wall to stone)
26FLOORING
27Supplying and fixing in cement sand mortar 1:4 sand or other approved stone dassa or coping of thickness 75 to 100 mm (Machine cut) : Plain Tikaridar. (at top of planter wall
28MISCELLANEOUS
29Aggregates 90 mm to 45 mm (hand broken)
30Painting parking boundary marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. (two or more coats)
31Providing and fixing sand stone Dustbins in 100 mm thick yellow sandstone with jali and carving properly shaped as per design of approved size, quality and standard specifications with removable metal bin inside properly fixed to stone body approved design pattern (shape) and specifications including c c 1 :2 :4 grouting, all materials, labor and T & P etc. required for proper completion of work as directed by engineer - in -charge.
32EXTERNAL PUMPING
33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
3425 mm nominal outer dia .Pipes.
3532 mm nominal outer dia .Pipes.
3640 mm nominal outer dia .Pipes.
3750 mm nominal outer dia .Pipes.
3862.50 mm nominal inner dia Pipes.
3975 mm nominal inner dia .Pipes.
40Hume Pipe & Cover
41Providing at site, lowering & laying in trenches, aligning & jointing of RCC pipes NP2 class (with s/s ends IS: 458 - 1988 (amended up to date) marked and manufactured through spun process at all levels with Rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of Rubber gaskets lubricants) as per drawing, sectional hydro testing of the sewer pipe line (including cost and conveyance of water to site for testing) etc., complete as directed by Engineer. Note : E/w to be measured and paid separately. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers, Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable
42300 mm internal diameter
43Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade & PN-6 for potable water as per IS 4984 (amended upto date) in trenches complete with all accessories like Bend, Tee, Reducer, Stub end, End cap etc including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.
4475 mm dia
45Construction of brick masonry valve chamber for different type of valves with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand), wall 230 mm thick, top cover slab 150mm thick RCC M20 grade (1:1½:3 i.e. 1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) with C.I. surface box with hinged cover 100x100x75mm (deep) including earthwork excavation, 100mm thick leveling course of PCC M10 (1:3:6 i.e. 1 Cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer.
4660cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve
47Providing & fixing of Drinking water fountain with Ro filtration and water cooler with tone jali pannel and sinage as per approved design & specification all complete in direction of engineer in charge
48HORTICULTURE
49Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately).
50Grassing with "Doobs" grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed.
51In rows 7.5 cm apart in either direction
52Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart.
53Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 300 mm min. height ground covers at site in 0.3 m dia holes, 0.3 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
54Wedelia trilobata ( SunFlower Family)
55Alternathera green (Parrot Leaf)
56Iresine herbstii (Blood Leaf)
57Ophiopogon Black ( Lily Turf, Mondograss)
58Asparagus myerii (Fox Tail)
59Lantana sellowiana
60Rhoeo spathacea "Compacta‘ ( Oyster, Boat Lily)
61Golden duranta
62Pennisetum setaceum (Fountain Grass)
63Per Pennsetum rubrum
64Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
65Ficus panda
66Tecoma capensis ( Ratanjot)
67Clerodendron inermii ( Choti Aari)
68Tabernaemontana variegated ( Chandni)
69Hamelia patens ( Firebush, Thal Kamal)
70Hibiscus variegated ( Guddal)
71Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 600 mm min. height shurbs at site in 0.45 m dia holes, 0.45 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
72Cestrum nocturnum
73Tecoma gaudichaudi
74Murraya exotica
75jatrofa dorf-3" feet
76techoma stans-3" feet
77Plumeria rubra( singapuri Champa) - 3" feet
78Murraya paniculata -3" feet
79Thuja occidentalis -3" feet
80ficus benjamina
81Nerium Oleander  drwaf
82Supply and planting following species best quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
83Plumeria alba ( Champa)
84Neem(Azadirachta indica)
85Bauhinia blakeana (Arckid)
86Bottle Brush(Callistemon Lanciolatous)
87Bougain villea
88Cassia fistula
89Ficus religiosa
90Ficus benghalensis
91Largerstomea speciosa
92Putranjiva roxburghii
93Terminalia arjun
94Cassia Siamea
95Pongamia pinnata
96Nerium oleander
97Tabebunia roseta
98Acacia arabica
99Dalbergia sissoo
100Millingtonia hortensis
101Terminalia arjuna
102Neolamarcika cadamba
103Nyctanthes arbor-tristis
104Boswellia serrata
105Schleichera trijuga
106Mimusops elengii
107Albizzia lebbeck
108Providing and Fixing of Stone sculpture of height 2.4 mt as per the design content in jaisalmer stone on. as per drawing including carving, cladding etc all including required DASA copings and all attached and fixing with SS clamps and fasteners with tenax chemical ,including Planning, developing, making base, carving work, polishing, all loading-unloading, transportation, scaffolding, hoisting, installation with all required T&P (including white cement, pigment, Chemical, SS clamps and fasteners of approved brand etc.), fixing over/on base/surface as per shape-size & placement of approved drawing , finishing, surface treatment etc. coveringproperly till the date of opening/inauguration of site etc. under the direction of engineer incharge and as per approval from Architect.
109P&F LATERAL , Driping
110Providing and fixing of Polyplast Plain Lateral Pipes of 16MM including all fittings.
111providing and fixing polyplast inline lateral 2 LPH of 16 MM including all fittings.
112providing and fixing of pop-up plastic sprinkler for commercial landscaping.
113providing and fixing of grommet and take off for connection of submain to lateral/dripline 13x16 MM
114providing and fixing of Drip irrigation joiner 16 mm
115providing and fixing of End stop for thin wall lateral 16 mm
116providing and fixing of Drip irrigarion flush valve
117Supplying, fixing, testing commissioning of butterfly valve (PN 16) with Bronze/ Gunmetal seat duly ISI marked conforming to IS 13095-1991 complete with flanges,Nuts, Bolts, washers, gaskets of following sizes as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work.
11880 mm dia
11950 mm dia
120ProvidingandfixinggunmetalgatevalvewithC.I.wheelof approved quality (screwed end) :
12140 mm nominal Bore
122EXTERNAL WATER SUPPLY (MANUAL)
123Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
12425 mm nominal bore
12520 mm nominal bore
126ProvidingandfixinggunmetalgatevalvewithC.I.wheelof approved quality (screwed end) :
127450 mm nominal Bore
128Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 90mm long. Weighing not less than 93 gms
129Head Unit
130Disc FILTER 40 M3/HR., 2.5
131Providing,installation,testingandcommissioningofDiaphragm TypePressureGaugesDialsize150mmglycerinefilled shatterproofglass,Overrangeprotection:125%ofmaximum pressure,Materialofsensorandotherwettedparts:SStype316, Housing material: Die cast aluminium
132Pump for Driping system
133Supplying and installation of Mono Blockpump sets I.S.I. Marked (IS : 8034-1989 ) of approved make, making connection suitable for T.W./D.C.B./Open well. The job includes screwing and welding of flanges on G.I. riser pipes, installation of complete fitting and accessories, with riser pipes, jointing of electrical cables and other connections making switch board electrical connections, all labour for testing of monoblock pump set and supply of water to water mains, complete in all respect . Automatic/ Maunal operating pump Control panel inculded. Flow = 8 m3/Hr and Head 25 Mtr (1W+1S)
134Providingandfixinggunmetal non-returnvalveofapproved quality (screwed end) : 50 mm Nominal Bore Horizontal
135Pump for Manual Operation
136Supplying and installation of Mono Blockpump sets I.S.I. Marked (IS : 8034-1989 ) of approved make, making connection suitable for T.W./D.C.B./Open well. The job includes screwing and welding of flanges on G.I. riser pipes, installation of complete fitting and accessories, with riser pipes, jointing of electrical cables and other connections making switch board electrical connections, all labour for testing of monoblock pump set and supply of water to water mains, complete in all respect . Automatic/ Maunal operating pump Control panel inculded. Flow = 10 m3/Hr and Head 25 Mtr (1W+1S)
137Supplying and installation of Automation Controller 4 Station
138Supplying and installation of 1.5 Sq.MM Single core wire
139CCTV
140SITC ofDome Camera: 1/2.8” progressive scan CMOS or Better,Varifocal lens 3.3 - 8.9 mm with remote focus & zoom (±2mm), F1.8 P-iris, IR corrected or Better,Horizontal field of view: 100°–36° Vertical field of view: 53°–20° or Better,Day and night-Automatic/manual/scheduled,Minimum illumination /light sensitivity -Color: 0.1 lux at 50 IRE F1.8 B/W: 0.02 lux at 50IRE F1.8,Shutter speed-2 s to 1/66500 s,Video compression-H.264 Baseline, Main and High Profiles H.265 Main Profile-Motion JPEG,Resolutions and frame rates (H.264)/(H.265)-1920 x 1080 @ 50 fps,Multiple, individually configurable streams in H.264, H.265, and Motion JPEG Controllable frame rate and bandwidth,Image settings-Saturation, contrast, brightness, sharpness, WDR-120db , white balance, day/night threshold, tone mapping , exposure mode, exposure zones, defogging, barrel distortion correction,compression, rotation: 0°, 90°, 180°, 270° including Corridor Format, mirroring, dynamic text and image overlay, privacy masks, polygon privacy mask,Audio /Alarm-Audio 1 Line input & 1 line output, AGC,Alarm 1 Digital imput & 1 Digital Output ,Security -Password protection, IP address filtering, HTTPS encryption, IEEE 802.1X (EAP-TLS), network access control, digest authentication, user access log, centralized certificate management, brute force delay protection, signed firmware, secure boot.Supported protocol,-IPv4, IPv6 USGv6,ICMP, HTTP, HTTP/2, HTTPS, SSL/TLS, QoS Layer 3 DiffServ, FTP, SFTP, CIFS/SMB, SMTP,mDNS( Bonjour), UPnP, SNMP v1/v2c/v3 (MIB-II), DNS, DDNS, NTP, RTSP, RTP, RTCP,SRTP, TCP, UDP, IGMPv1/v2/v3, RTCP, ICMP, DHCPv4/v6, ARP, CDP,SOCKS, SSH, SIP, LLDP, MQTT v3.1.1, Syslog, link local Address,Programming Interface- ONVIF® Profile G, ONVIF® Profile S, ONVIF® Profile M and ONVIF® Profile T,Analytics-Object analytics (Human & Vehicles like Cars, Buses, Trucks, Bikes), Motion Detection, Line crossing, Loitering detection, Video Motion Detection, Active tampering alarm, Support for Camera Application Platform enabling installation of third-party applications,IP52 & IK10, IR Illumination-upto 40 mtrs (Should auto adjustable with Zoom),Sustainability-PVC free,1024 MB RAM, 8192MB Flash,Power over Ethernet (PoE) IEEE 802.3af/802.3at Type 1 Class 3 Normal operation 4.8W, max 8.9 W,Support for microSD/microSDHC/microSDXC card Support for SD card encryption (AES-XTS-Plain64 256bit),Operating conditions-"0 °C to 50 °CHumidity 10–85% RH (non-condensing),Approvals-EN 50121-4, EN 55032 Class A, EN 55035, EN 61000-6-1, EN 61000-6-2, FCC Part 15 Subpart B Class A, ICES-3(A)/NMB-3(A), IEC 62236-4, KC KN32 Class A, KC KN35, RCM AS/NZS CISPR 32 Class A, VCCI Class A,CAN/CSA C22.2 No. 62368-1, IEC/EN/UL 62368-1, IEC/EN 62471, IS 13252,IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-6, IEC 60068-2-14, IEC 60068-2-27, IEC 60068-2-78 IEC/EN 60529 IP52, IEC/EN 62262 IK10,NIST SP500-267,NDAA Compliant,The Camera to be provided by the bidder- all the components / parts / assembly / software used in the offered hardware and software, should not becomplying to GB28181, GB/T 28181-2011; GB/T28181-2011; GBT 28181-2011; GBT28181-2011 standards. There should be no option to activate or deactivate these standards in the camera web page/Settings.,Pixel counter, 1 YEAR Warranty
141SITC ofHigh Definition Outdoor 2MP Bullet Camera Progressive scan RGB CMOS 1/2.8” or better,Minimum Illumination-Color: 0.20 lux, at 50 IRE F1.7B/W: 0.05 lux, at 50 IRE F1.7 0 lux with IR illumination o,IRIllumination-Built in Or External Optimized IR with 40meter range, 850nm, with adjustable angle and intenstity or better,Lens- 3–8 mm, Remote focus and zoom, P-Iris control, IR corrected,Field of View-110°–38°° or better,Electronic Shutter-1/60000 s to 2 s or better,Resolution-1920x1080 or Better,H.264 in Baseline, Main and High Profile MPEG4, H.265Main Profile,MJPEG,50 FPS at all resolutions with Controllabe Bit Rate/ Bandwidth and Frame Rate,Ability to change the GOP/GOV Length to optimize the bandwidth and storage,Image reproduction-Compression, Color, Brightness, Sharpness, Contrast, Local contrast, White balance, Exposure control,Image Compression-The camera support scene adaptive bitrate control, in order to lowering bandwidth and storage requirements.The camera shall support automatic dynamic GOP for optimal bitrate utilisation. The camera shall support automatic dynamic ROI to reduce bitrate in unprioritized regions.Minimum 4 individually cropped out view areas,Minimum 4 Streams @ H.265, 1080P, 25 fps which can be individually control and configure.Aanalytics-Inbuilt Motion Detection,Line crossing ,Loitering , active tampering alarm Object Classification (Human & Vehical ) and camera should support 3rd party edge based analytics.Aspect Ratio-16:9 or 9:16 without change in image quality or change in Image,ECC- Automatic/ Manual,WDR-120 ord Better,Privacy mask,Event Triggers-A. The camera shall be able to send and received trigger directly from any other camera without interface of VMS. B. Intelligent Video, Edge Storage Events, Software Alarms, Camera Tampering, Intelligent Motion Detection, Edge Based Analytics,Event Actions-File upload: FTP, HTTP, network share and email Notification: email, HTTP and TCP PTZ funtion, Edge Storage/ NAS Storage, Pre & Post Alarm Recording, Actions- configurable by web interface, IR Illuminator on/off,Built in SD card slot with support upto 1 TB.The Camers shall have the feature to directly record the videos/ images onto Nas without any Software,Protocals-IIPv4/v6, HTTP, HTTPSa, SSL/TLSa, QoS Layer 3 DiffServ, FTP, SFTP, CIFS/SMB, SMTP, Bonjour, UPnP, SNMP v1/v2c/v3 ,SRTP, DNS, DynDNS, NTP, RTSP, RTP, SRTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS, SSH, LLDP,MQTT,,Text Overlay-Date & time, and a customer-specific text, camera name, graphical image etc,Security-Password protection, IP address filtering, HTTPS encryption, IEEE 802.1X network access control, Digest authentication, User access log, Centralized certificate management,Camera block Un-authorized firmware installation,Camera should check authenticity of firmware every time it re-boot,Camera should not support GB/T 28281 and there should not be any option to activate /de-activate this protocol through web browser or camera firmware,Camera should be NDAA complied,Audio streaming - Audio in, simplex,External microphone input or line input,Audio compression-24bit LPCM, AAC-LC 8/16/32/48 kHz, G.711 PCM 8 kHz, G.726 ADPCM 8 kHz, Opus 8/16/48 kHz Configurable bit rate,Memory-1GB RAM, 512 MB Flash or better with Inhouse processor,RJ 45, 100 Base TX.,IEEE 802.3af/802.3at Type 1 Class 3, max 13 W or better,Operating Temperature- -30 °C to 60 °C,Operating Humidity-Humidity 10–100% RH (condensing),IP66/IP67-, NEMA 4X-, and IK10-rated casing,PVC free,Certification-EMC EN 55032 Class A, EN 50121-4, IEC 62236-4, EN 55035, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2 Safety IEC/EN/UL 62368-1, IEC/EN/UL 60950-22, IEC 62471 Environment IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-78 Network NIST SP500-267,The camera shall be monitored by a Watchdog functionality, which shall automatically re-initiate processes or restart the unit if a malfunction is detected,1. The camera shall provide a log file, containing information about the 200 latest connections and access attempts since the unit’s latest restart. The file shall include information about the connecting IP addresses and the time of connecting. 2. The camera shall provide a connection list of all currently connected viewers. The file shall include information about connecting IP address, time of connecting and the type of stream accessed.Onvif S & G&T. 1YEAR Warranty.
142SITC of PTZ Camera: 1/2.8” progressive scan RGB CMOS,Resolution-Minimum 2MP or better as applicable,Frame Rate-60/50 fps (60/50 Hz) in all resolutions,Compression-H.265,H.264 , Motion JPEG,Streming-Minimum 4 Streams @ 1920x1080, H265, 25 fps,Alarm- 1 Input,1Output-,Focus Mode-Auto/Zooming/One Push Manual,Panning Range & Speed-Pan: 360° endless, 0.1°- 350°/s, Tilt: 180°, 0.1°- 350°/s,Presets-50 Presets or higher,Auto Track, Auto Pan, Preset control, patrol Modes,Pre/Post Alarm buffer,user id/password,HTTP (SSL/TSL),10/100 base TX ethernet,-Protocol-Minimum TCP/IP, HTTP, RTP, RTSP,Static/ Dynamic or both,Remote Administration-Remote configuration client with a channel recording feature support,Remote System update over network using web client,PC Client-PC Application client with a channel recording feature support,Web Client-Viewer thruogh HTTP(min). System Configuration Setting/streaming,Simultaneous Connection-5 User or More,Lens Type-Varifocal Min 4.3-129 MM orequivalent or better,WDR-120DB,Auto Exposure-Automatic Level Control/Electrnic Level,Minimum Illumination-Color: 0.1 lux at 30 IRE F1.4 B/W: 0.01 lux at 30 IRE F1.4,4 or Higher Privacy ZonesAGC,Electronic Sutter-11/66000 s to 2 s,White Ballence,Automatically removable infrared-cut filter,iris Control, Oprating Temperature-Minus 30 °C to 50 °CHumidity 10–100% RH (condensing),Device shall work on POE, Suitable POE Power Injector or 230v AC Power adoptor shall be included,OSD,Housing Indoor-Plastic/Alluminium Construction, IK10 Rated,Housing Outdoor-IP66-, NEMA 4X- and IK10-rated Aluminum casing, polycarbonate (PC) dome,Event Triggers-Audio: Audio detection Device status: Above operating temperature, Above or below operating temperature, Below operating temperature, Fan failure, IP address removed, Network lost, New IP address, Shock detected, Storage failure, System ready, Within operating temperature, Edge storage, Recording ongoing, Storage disruption I/O: Digital input, Manual trigger, Virtual input MQTT subscribe PTZ: PTZ malfunctioning, PTZ movement: Camera 1, PTZ preset position reached: Camera 1, PTZ ready Scheduled and recurring: Scheduled event Video: Day-night mode, Live stream open,Event Actions-Play audio clips, day-night mode, go to preset position, guard tour, I/O, upload of images or video clips via FTP, SFTP, HTTP,HTTPS, network share and email, notification to email, HTTP, HTTPS, TCP and SNMP trap, overlay text, prioritized text, record video to SD card and network share, WDR mode MQTT publish,Password protection, IP address filtering, HTTPSa encryption, IEEE 802.1Xa network access control, Digest authentication, User access log, Centralized Certificate Management, Brute force delay protection, signed firmware, Secure Boot,1GB RAM, 512 MB Flash The camera shall have inhouse processor for better performance and support for 3rd Party analytics,Certification-UL, CE, FCC Part 15 Subpart B Class A,NIST SP500-267,IEC 60068-2-6,VCCI Class A,RCM AS/NZS CISPR32 Class A,IEC 60068-2-27 IEC/EN/UL 62368-1, IEC/EN/UL 60950-22, IEC/EN 62471 risk group 2, IS 13252, NIST SP500-267,Built-in Analytics-Video Motion Detection, Fence protection,Loitering, Auto Tracking, shock detection and The camera shall provide a platform allowing the upload of third party applications into the camera,Support of 3rd party Analytics-The camera should support 3rd party edge based analytics-NDAA Complaint-The proposed camera should be NDAA Compliant-The proposed camera should be NDAA Compliant,Protocol-The Camera to be provided by the bidder all the components / parts / assembly / software used in the offered hardware and software, should not be complying to GB28181, GB/T 28181-2011; GB/T28181-2011; GBT 28181-2011; GBT28181-2011 standards. There should be no option to activate or deactivate these standards in the camera web page/Settings.The Camera to be provided by the bidder should not have Hisilicon chipset/Processor,The camera should send trigger via HTTP/HTTPS to any compatible IoT Devise,onvif-G and S required. 1YEAR Warranty
143SITC of 60 CH licenses included, can be upgradedup to 64 licenses (sold separately),Processor-Intel® Xeon® Silver -Storage-64 TB (8x8 TB) Enterprise Class HDD, 7200 rpm56 TB usable space after RAID Additional storage: 4 free bays RAID levels: 0, 1, 5, 6, 10,O.S-Microsoft Windows 10 IoT Enterprise Operating system drive: 240 GB SSD,2x RJ45 Ports,Shall support recording up to 64 video channels with a total recording rate up to 512 Mbit per second or better,Software-Compatible with Cameras, Encoders including HD, Standard resolution, High Resolution, Pant Tilt, Zoom, Thermal, Cameras, Access Control, IP Speakers, Alarm IO Modules,H.264 (MPEG-4 Part 10/AVC), Motion JPEG or better,Map function,PTZ Control,Smart Search for recordings,Playback-Up to 64x or frame by frame Up to 25 cameras synchronized playback,Export-Manual and scheduled export, Single images in JPEG format, Video in ASF format, Digital signature on exported recordings, Standalone player,Scheduled recording-The software shall allow recordings for continous, motion based, event based, or customized as per user/ scheduled,Alarm Manager,Microsoft Active Directory support-Yes, multiple user access levels with password protection using local or Windows domain users (Active directory),Event triggers-Events triggered by video motion detection, Active Tampering Alarm, Cross Line Detection, External I/O, Action button, System triggers and device event triggers, Manual Triggers, Edge Based Analytic Triggers,Power-750 W (100-240 V AC, 10 - 5 A, 50/60 Hz,Connectors-2x USB 3.1,1x USB 3.1 Type-C,2x USB 2.0,x VGA,1x Serial port,Operating conditions-10 °C to 35 °C (50 °F to 95 °F),The Manufacturer shall support free upgrades for Software and firmware,Certification- EN/IEC/UL 60950-1, FCC part 15 class A, VCCI class A, RCM AS/NZS CISPR 32 Class A, EN 55032, class A, ICES-003/NMB-003 Class A, KC KN32 Class A, KN-35, EN 55024, EN/IEC 61000-3-2, EN/IEC 61000-3-3, NOM, BSMI, EAC",Form Factor-Rack/Tower, 1 YEAR Warranty,Axis, Sony, Bosch
144Supply, Installation, Testing and Commissioning of 55" 4K UHD (3840x2160) Ready resolution Android LED display with built in 2.4 Ghz Wifi, 1.1 Ghz Built in Quad core processor, 2 GB DDR3 RAM, 16 GB Memory, built in Triple Mali 600 MHz GPU, with 2K HDR, Dolby Audio, Built in Wifi and Chromecast, Built in web browser, HDMI CEC, HDMI ARC, Built-in Bluetooth Ver.4, 20W built in speakers, HDMI 2.0 X 3, AV X 1, USB 2.0 X 1, RJ45 X 1, Headphone Out x 1, SPDIF Out x 1 As per tender Specificaiton.
145Workstation:Processor: Intel Core i5, 6 Core, 12M cache, base 2.7GHz or better,RAM-16 GB DDR4,HDD-500GB,Graphic Card: 1x Nvidia 4GB Graphics,Network-1G Ethernet,Expansion Slots-1 half height PCIe x16 Gen4; 1 half height PCIe x4 Gen 3,I/O Ports-1 – USB 3.2 Gen 2 Type C 4. As per tender specificaiton.
146SITC of Industrial Grade Switch: 10 Port Industrial Managed Switch is fully Managed L2 switch, with Store-Forward architecture, fan-less and energy-saving design, with 8 * 10/100/1000Base-T PoE(af/at) Copper port and 2 * 1.25G/155M SFP fiber port. IEEE802.3af, IEEE802.3at 30W per port Total PoE Budget for the Switch : 240W, IPSMG 308-2S is designed with protection against Lightning, anti-static and operate in -40°C to 75°C for harsh environments such as Industrial automation, Security, Power system, Intelligent transportation systems (ITS), Mining, Water Management & Oil fields, ERPS (G.8032) Loop Protection Redundant dual DC input power 12/24/48VDC (9.6 to 60V DC). 48V for PoE function Provide Reverse Polarity protection, Overload current protect function 2.25KV DC Hi-pot isolation protection for Ethernet ports and power 4KV surge protection for Ethernet and Fiber ports SFP 100/1000Base-X ,IP40 Aluminum metal case DIN-rail mounting, Wall Mount kits optional Supports EFT protection 6000VDC for Power port Supports 8 / 15KV ESD protection -40°C to 75°C Operating temperature Low power consumption. As per tender Specificaiton
147SITC of Layer-3 28 Port Rackmount L2+/L3 Managed 10G Industrial Ethernet Switch, 16xGigabit SFP ports (or 16x Gigabit Ethernetport)+4x10Gbps SFP+ ports + 8xGigabit Combo ports 10Gbps SFP+ ports support 10G/Gigabit, Auto NegotiationSupports IGMP Snooping/MLD Snooping filter multicast packets Supports IEEE 802.1Q VLANSupports QoS, enabled 8-queue mappings, increase network stability Supports STP/RSTP & MSTP Supports SNMP v1/v2/v3, ensure networking safety managementSupports Link Aggregation (static aggregation/LACP) Supports ACLSupports Port mirroring, convenient for online debug Supports Port transmission, Speed limit\broadcast storm suppression\ multicast storm suppression \ unknown unicast storm suppression Support Layer 3 switching function (Static route/Rip/OSPF/VRRP) Supports Power, Port abnormal status relay output alarm Wide working temperature : -40°C to 75°C IP40, fanless design, industrial standard, rackmount installation.Approvals:EMI : FCC Part 15, CISPR (EN55022) class A EMS :IEC(EN)61000-4-2(ESD) IEC(EN)61000-4-3(RS), IEC(EN)61000-4-4(EFT) IEC(EN)61000-4-5(Surge)IEC(EN)61000-4-6(CS) IEC(EN)61000-4-8 IEC 60068-2-27(Shock) IEC 60068-2-32(Freefall As per Tender Specificaiton.
148SITC of12Port Fully Loaded LIU Lockable 19" rack mounted with 1U height, Sliding Drawer Type with 4 Cable entry/exit points ( covered with rubber grommets),Powder coated mild steel,Accommodation of single mode cable multimode fibers Capable of supporting SC and LC interface - For 24 Port with SC Coupler Configurable. Fits up to four 6 pack plates/Angled 6 pack plates Management rings within system to accommodate excess fibre bend radius.Optical Fibre Adapter Plates: Greater Asset Utilisation – Easily Expandible – allows multiple generational uses of the enclosure for the same rack area. Our blank plates and a small profile plate ensures you only pay for the adapters you need.,ISO/IC 11801, ANSI/TIA/EIA 568.B.3-2000, ANSI/TIA/EIA-492, TELECORDIA GR-409, ICEA-596,Plate Material: Black Electroplate or Thermoplastic,Single Mode Pigtail:SC / LC LSOH Jacket - Reduces toxic / corrosive,1.5 Mtrs,100% Factory polished, tested and Guaranteed Performance,ROHS Compliant As per tender Specificaiton.
149SITC of24Port Fully Loaded LIU Lockable 19" rack mounted with 1U height, Sliding Drawer Type with 4 Cable entry/exit points ( covered with rubber grommets),Powder coated mild steel,Accommodation of single mode cable multimode fibers Capable of supporting SC and LC interface - For 24 Port with SC Coupler Configurable. Fits up to four 6 pack plates/Angled 6 pack plates Management rings within system to accommodate excess fibre bend radius.Optical Fibre Adapter Plates: Greater Asset Utilisation – Easily Expandible – allows multiple generational uses of the enclosure for the same rack area. Our blank plates and a small profile plate ensures you only pay for the adapters you need.,ISO/IC 11801, ANSI/TIA/EIA 568.B.3-2000, ANSI/TIA/EIA-492, TELECORDIA GR-409, ICEA-596,Plate Material: Black Electroplate or Thermoplastic,Single Mode Pigtail:SC / LC LSOH Jacket - Reduces toxic / corrosive,1.5 Mtrs,100% Factory polished, tested and Guaranteed Performance,ROHS Compliant As per tender Specificaiton.
150SITC of 3mtr.SC-LC Single Mode OFC Patch Cords 9/125 Micron,SC or LC LSOH Jacket - Reduces toxic / corrosive,100% Factory polished and tested, Less than 0.35dB per connector, 0.4dB/km over 1310nm to 1625nm,ROHS Compliant,LSZH,1.6 mm,3mtr.Tight buffered,temp.-40 Degree C to +85 Degree C, LS0H IEC 61034-1 & 2, IEC-60332-1, IEC-60754- 1 & 2. As per Tender Specification.
151SITC ofOutdoor Rack 4U Rack,IP65
152SITC of 19" 24U Indoor Close Rack
153SITC ofOutdoor CAT-6 Cable; 23 AWG solid bare copper,Unshielded twisted pair cabling system, TIA / EIA 568-C.2 Category 6 Cabling system oudoor cable,Cat 6 ANSI/TIA/EIA-568-C.2, ISO/IEC 11801, IEC 6074-1(Toxicity), IEC 6074-2 (Acid Gas) standards,Supports ultrahigh speed data networks such as Gigabit Ethernet (1000 Base-T and 1000 Base-TX) and beyond,Propagation delay:535ns/100m @ 250 MHZ,Mutual Capacitance:5.6nF/100m NORMAL,ETL Verified, UL Listed andUL channel verified- All three Certificates are mandatory,All passive cabling must be from same OEM ( UTP and Fiber),As per Tender Specification
154SITC of6core Optical Fiber Cable Armored Single-Mode OS2,optical fibres in water blocked loose tube, taped, corrugated steel tape armoured (STA) polyethylene (HDPE) outer sheathed embedded with two steel wires on the periphery. The cables are with UV Stabilized PE Jacket and protected from Rodent attacks. complying to ISO/IEC 11801, EN50173, ANSI/TIA 568-C.3, Telcordia GR-20; suitable for use in indoor / outdoor ducts, direct burial and backbone cabling,Single Mode, 9/125 micron primary coated buffers, OS2 (IEC 60793-2-50, B1.3 and ITU T G652.d). Shall be manufactured using Vapor Axial Deposition technology.Polybutylene, Terephthalate(PBT),complying to ISO/IEC 11801 2nd Edition, type OS1/OS2; AS/ACIF S008; AS/NZS 3080 ; TIA/EIA 568.C.3; IEC-60793-1, 60793-2 EN50173, ANSI/TIA 568-C.3, Telcordia GR-20; As per tender Specification.
155SITC of25 mm Conduit MS with complete accessories as required.
156SITC of HDPE Pipe 32 MM
157ITC of Hard & Soft Soil Digging
158SITC of Replug RG45 Connector for Cameras
159SITC of HDMI Cable for NVR to Video Wall
160Audio
161Supply, installation, testing and commissioning of 2-way, 5.25-inch or better IP55 rated surface mounted coaxial music and PA loudspeaker. The louspeaker shall meet the following criteria: Frequency range (-10dB) of 60Hz to 20kHz; Power handling of 200Watt peak; Nominal dispersion of 90°(H) × 80°(V); Sensitivity of 87 dB SPL and Max SPL of 105 dB SPL peak or better;Nominal impedance of 8 Ohms with an Integral multi-tap Transformer with selectable tap settings of 6/12/25/50W@100V or better. The loudspeaker system shall be enclosed in engineered-plastics with an In-built waveguide designed to provide uniform area coverage across the loudspeakers frequency range. UL-1480A rated.
162Supply, installation, testing and commissioning of 8 channel class D Networkable Power amplifier with a Max Output Power of 8x500W@8 ohms, or bridged mode output power of 4x 1000W @ 8/4 ohms. 20Hz - 20 KHz, SNR of 102dB and THD + N of <0.4% with built inprotection such as Limiters, Temperature, DC, Short Circuit, Peak Current Limiters, Turn on delayetc. Built in DSP for Matrix routing, Speaker equalization, Delays, Array EQs etccomplete with Ethernet Port for Network Control, programming and monitoring. Shall offer optional Network audio connectivity (Dante ) through expansion slot..
163SITC of digital audio DSP with 32-bit fixed/floating-point DSP 456 MHz/ARM Cortex-A8 600 MHz processor or better. DSP shall have 12 balanced inputs and 8 balanced output channels for microphone or line-level analog audio signals, each independently controllable . The DSP shall have Dante digital audio networking up to 64 x64 channels, an Ethernet connection for control and programming on an RJ-45 jack. GPIO – 5x5 general-purpose I/O control, USB audio and 8 or better digital output channels on an RJ-45 jack. It shall haveSerial Port – 3-wire RS-232C (DTE) serial interface connection. It shall Supports remote zone controllers. Dynamic Range> 115 dB, A-weighted 20 Hz – 20 kHz;THD : < 0.002 % or better ,Maximum Input Level +24 dBu;Phantom Power +48 VDC, 10 mA, selectable per input. The audio DSP shallinclude configurable signal processing, signal routing and mixing, equalization, filtering, dynamics, delay, as well as control, monitoring, and diagnostic tools. The audio DSP shall control and proxy allexpansion devices and other Dante endpoints.
164SITC of networked audio output expansion device with 4 line-level output channels.The audio output device shall be designed in such a manner  that provide audio and control by Layer-2 protocol . It shall have Local storage of Emergency Messages in non-volatile memory, receive Power over Ethernet (PoE) utilizing a single (CAT5) network cable to a rear panel RJ45 connector. The output device shall provide four removable terminal block connectors for linelevel audio outputs, four control inputs, and four control outputs. It shall have channel-to-channel and device-to-device failover,local non-volatile storage of Emergency Messages,dual PoE capable with alternate powering from auxiliary 24V DC supply (dual inputs),  Page Active Relays, Control Inputs, and Control OutputsThe audio output device shall provide local digital audio signal processing and local storage of configuration data,signal processing including volume control, filters, compressor/limiting, delay, speaker equalization. The audio output device shall indicate signal and clip with LEDs on the front panel.
165SITC of networked messaging processor. The Playing live & Pre-recorded server shall networked based & to be rack mountable in one rack space (1RU) and shall support advanced paging functionalities such as recorded message storage and playback, system configuration storage, event scheduling, time server support, storage of logged system data, VoIP triggered paging, email notification, and remote third party control capability. The processor shall feature a status LED and separate ports for TCP/IP Control and networked based Layer-2 or above protocol . The message Server shall be CE marked and shall be compliant with the RoHS directive.
166SITC OF Paging Station, 10 Buttons with hand-held microphone (EN 54-16 certified) Supply, installation, testing and commissioning of EN 54-16 certified wall-mounted paging station to provide paging audio and network control data via  network cable and using PoE power from RJ-45 connector. It shall have 10 or more buttons with mutliple functions e.g .direct page ,zone recall etc. It shall provide multi level paging priorities functions and facility for  override, store and forward, and keypad lock-out . It shall have inbuilt DSP ,data storage. It should have  LED/LCD backlit screen,  access via special code ,sutiable to work in high noise area with inbuilt  noise-cancelling microphone. It shall be CE, RoHS compliant and  EN 54-16 certified.
167SITC OF audio input device with 6 channels of BGM or user configurable mic/line audio ,Supply, installation, testing and commissioning of networked audio input expansion device .The audio input device shall provide audio and control via networked based Layer-2 or above protocol. It shall receive Power over Ethernet (PoE). The audio input device shall provide four sets of dual RCA connectors plus removable terminal block connectors for line-level inputs, two microphone/line inputs with phantom power, four paging inputs, six Rj45 outputs, four control inputs, and four control outputs. Software-configurable local audio signal processing including gain, filters, and compressor/limiter. The input device shall indicate signal and clip with LEDs on the front panel. The input device shall be CE marked and shall be compliant with the RoHS directive.
168Supply, installation, testing and commissioning of professional multisource CD/USB/SD-card music player with  unbalanced outputs  2 x RCA + COMBI RCA,  integrated FM RDS and  tuner with RS232 control, IR remote included, rack mountable.
169Supply , installation , testing and comissioning of Rack Finishing- with OFC Termination Swith all necessary accessories to comply the installation
170Supply , installation , testing and comissioning of 8 x 10/100/1000T ports (POE) 4 x 100/1000x SFP Industrial L3Switch with all necessary accessories to comply the installation
171Supply , installation , testing and comissioning of 1000BaseLXSFP (10km) Swith all necessary accessories to comply the installation
172Supply , installation , testing and comissioning of LIU Single Mode with Piggtail and Adapter (Patch Panel for 12 core with inbuilt pigtails)with all necessary accessories to comply the installation
173Brass Metal Nozzle 20 Nos 18 W Underwater Lighting 12 Volt DC system along with IP 65 Driver Submersible Pump -5Hp Light Controller Civil Work of Fountain Plumbing of complete Water Body UPVCPPR including control valves and accessories Electrical Accessories like Cable ,Light Control Panel with MCBS etc Complete SITC Job of civil,plumbing,& Electrical work as per design
174Electrical
175Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for base flange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table P -01 for specs.) 8.0 Mtr
176Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) 70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . LED Street Light fixture 30 Watt
177Supply installation testing & Commissioning of ISO certified company made high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. ( See table P - 03 for specs.) OEM Must have Type test certificate for wind tunnel test for High mast fixtures. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
17816 Mtr HM (in 2 section)
179Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
180Single arm overhang
181Double arm overhang
182Supply and erection of Decorative Cast Iron pole as per approved design of following length with base plate on the cement concrete foundation of M-15 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III). The pole shall be made of Cast Iron as per IS 210:1993, precision machining and filling job to achieve good finish and a fine coat of primer on each element before assembling. After assembling of each element one coat of primer and two coats of P.U. paint are applied. Approved coloured UV resist coating of mat/ glossy/ metallic finish followed after air drying of pole. The pole shall have a weatherproof flush door and locking arrangements, two/ one arm bracket of length of 430/380mm complete in all respect. 2 Mtr.
183Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminous efficacy = 100 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current <750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
184Minimum lumen output 2500 lm Post top Luminarie
185Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
186High Power LED Flood Light 30W
187Providing & Fixing of IK10 IP65 protected 600 mm height LED Bollard Luminarie with base plate made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy = 90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency >85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. driver current <750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
188Minimum lumen output 980 lm Bollard
189Distribution Board
190Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters o
191Single pole MCB 6 A to 32 A rating
192Double pole MCB 40 A to 63 A rating
193Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) as per PWD specification for electrical Works with ISI marked (IS:12640-1) / conforming to IEC 61008 -1 , rated conditional s/c current of 10 KA, truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating, minimum phase termination capacity of 50 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
194Two pole 30 mA sensitivity 25 A rating
195Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
196IP-43 Double door (single phase), 12 Way (12 O/G +2 I/C)
197Switch Socket
198Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
19916 Amp. 1 Module switch With Led Indicator
200Providing & Fixing of modular type lockable feature socket duly ISI marked (IS :1293) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
20116 A 6 pin shuttered socket
202Providing & Fixing of following size mounting grid plates with cover plates as per PWD specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
2033 Module
204Providing & Fixing of following size hot dip galvanized M.S. box of 18 SWG as per PWD specification for electrical Works, with earthing terminal in recess/ surface suitable for modular accessories as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
2053 Module
206Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
2072 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
2082 x 6.0 sq. mm. + 1 x 4.0 sq. mm
209Outdoor Feeder Pillar Incomer: SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Thermal Magnetic release up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Single pole MCB, 6 A to 32 A rating Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/ IS-8623 & IEC-60529/ IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. Capacity , bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .600 mm long , 4 strip LED Type Indicating Light 230VRed/Green/White with Smooth Lens LED Type Indicating Light 230VYelolow/Amberwith Smooth Lens LED Type Indicating Light 230V Blue with Smooth Lens Outgoing: Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Single pole MCB, 6 A to 32 A rating consisting Cost Of Panel Box Made Out Of I6/14swg Ms Sheet Powder Coated IP42 Class Enclosre As Per Approved Design
210Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
211Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
21225mm x 6mm G.I. ( Hot Dipped ) Strip
213Cable & Wiring
214viding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un armoured / Armoured copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Copper conductor of electrlytic grade copper, purity >99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Armoured
21516.0 Sq. mm, 2 core
2162.5 Sq. mm, 2 core
2174.0 Sq. mm, 2 core
218roviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.
219Armoured Cable, 4.0 Sq. mm, 2 core
22035.0 Sq.mm, 3.5 core
22150.0 Sq.mm, 3.5 core
22295.0 Sq.mm, 3.5 core
223Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 -1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
2243.5 x 35.0 sq.mm
2253.5 x 50.0 sq.mm
2263.5 x 95.0 sq.mm
227Provision of Provisional sum to be used as tender document (fixed) : INR 50,00,000. Bidder should fill amount INR 50,00,000.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail