Tender For Repair Maintenance Of Electrical Equipment And Allied Works Under Ge (East) Mathura, mathura-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair Maintenance Of Electrical Equipment And Allied Works Under Ge (East) Mathura. Submission Date for this Tender is 09-01-2023. Coats and Jackets Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35239282
Corrigendum : Tender For Repair Maintenance Of Electrical Equipment And Allied Works Under Ge (East) Mathura
Open Tender
Indian
Uttar Pradesh
mathura
09-01-2023

Tender Details

Tender For Repair Maintenance Of Electrical Equipment And Allied Works Under Ge ( East ) Mathura- Dismantling Steel Tubular Poles Of Any Size Complete All As Specified And As Directed. 2 Supply And Erecting Steel Tubular Swaged Pole With Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts & Washers As Per Is 2713 ( Part-Ii ) 1980 Made Out Of Mild Steel Tubing, Type 410 Sp-55 ( 11.00 Metre Long ) Including Marking Pole No On Pole Including Painting Of Poles With One Coat Of Red Oxide Primer And Two Coat Of Aluminum Paint ( One Coat Before Fixing And One Coat Of Aluminum Paint After Fixing ) Over Exposed Surface And Two Coats Of Bituminous Paint Over Embedded Portion & The Portion Above Coping Shall Be Painted In Alternative Bands Of Black And Yellow Colour Starting With White Colour ( Each Band Of 30Cm Wide ) By Two Coats Of Super Enameled Paint Upto 1.5M Height Complete All As Specified And As Directed. Note : Earth Work And Pcc In Foundation Shall Be Measured Separately. 3 Supply, Installing And Testing Of Lightning Arresters Expulsion Type Complete With All Fittings, Transmission Class, Discharge Capacity 65 Kilo Amp Capacity Suitablefor 11 Kv Complete All As Specified And As Directed. 4 M&L For Fixing Air Break Gang Operated Switch Outdoor Type Ht 11 Kv Triple Pole Mechanically Operated Mounted On Ht Insulators Horizontal / Vertical Typeincluding Ms Galvanised Steel Frame With Operating Mechanism Worked From Ground Level Including Operating Rod Of Size 32 Mm Dia Gi Medium Grade For Current Rating Of Cap 400 Amps 11000 Volts With Locking Arrangement, Ms Clamps, Bolts, Nuts And Washers Etc Including Preparation Of Ms Surface And Applying Two Coats Of Aluminum Paint Over A Coat Of Red Oxide Primercomplete All As Specified And As Directed. 5 Supply And Fixing Drop Out Fuse Unit, Expulsion Type For Outdoor Air Break Gang Operated Switch, Single Pole, Mounted On And Including Insulators For 11 Kv Working Pressure Fixed To And Including Ms Channels With Nuts, Bolts & Washers Etc, Synthetic Bounded Fuse Tube Complete Suitable For Current Carrying Capacity Upto 100 Amps Complete All As Specified And As Directed. 6 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sq M On Plan And Nexc 1.5 M In Depth And Getting Out Complete All As Specified And As Directed. 7 Excavating In Trenches, N Exc 1.5 M Wide And More Than 1.5 M N Exc 3.0 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sq M On Plan And Nexc 3.0 M In Depth And Getting Out Complete All As Specified And As Directed. 8 M&L For Cement Concrete 1:4:8 Type D-2 ( Using 40Mm Graded Stone Aggregate ) As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed. 9 M&L For Cement Concrete 1:3:6 Type C-2 ( Using 40Mm Graded Stone Aggregate ) As In Foundationfilling And Mass Concrete Complete All As Specified And As Directed. 10 M&L For Cement Concrete 1:2:4 Type B1 ( Using 20Mm Graded Stone Aggregate ) As In Coping Complete All As Specified And As Directed. 11 M&L For Cable Route Indicator Showing Ht Cable And Route / Joint Of Cable With Arrow Made Of Pcc 1X2x4 Type B1 Duly Rendered With Plaster 10 Mm Thick Of Size 40 X 50 X 20Cm Fixed And Erected On Pcc Plateform Of Sixe 40 X 40 X 10 Cm Goruted In Grounts Duly Painted On Both Sides With Ht Cable Route Complete All As Specified And As Directed. 12 Dismantling Unserviceable Cross Arms, Clamps Etc And Removing From Site Complete All As Specified And As Directed. 13 M&L For Work Confirming To Fe-410-O Or Fe-310-O As In Cross Arms, Support, Bracings, Stiffeners, Clamps Channels Fabricated From Structural Steel Including Nuts, Bolts And Washers Welding, Bending Cold Or Hot Drilling Holes For Bolts In Any Shape Or Size All As Directed Including Two Coats Of Aluminium Paint Over A Coating Of Red Oxide Primer Complete All As Specified And As Directed. 14 Disconnecting And Taking Out Existing Unserviceable Defective Ht Cable Any Size Any Type From Trenches / Duct / Poles Including Taking Out Old Bricks Complete All As Specified And As Directed. 15 Supply Laying & Testingxlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) With Stranded Aluminum Conductor, 11000V Grade, Of Cross Section Area95 Sq Mm 3 Core Complete All As Specified And As Directed. 16 Supply Laying & Testingxlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) With Stranded Aluminum Conductor, 11000V Grade, Of Cross Section Area120 Sq Mm 3 Core Complete All As Specified And As Directed. 17 Supply Laying & Testingxlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) With Stranded Aluminum Conductor, 11000V Grade, Of Cross Section Area150 Sq Mm 3 Core Complete All As Specified And As Directed. 18 Supply Laying & Testingxlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) With Stranded Aluminum Conductor, 11000V Grade, Of Cross Section Area185 Sq Mm 3 Core Complete All As Specified And As Directed. 19 Excavating In Trenches Not Exceeding 1.5 Mtr In Depth And Not Exceeding 1.5 Mtr Wide For Laying Of Cables And Getting Out In Soft / Loose Soil Complete All As Specified And As Directed. 20 M&L For Sand Cushioning To Under Ground Cable In Trenchesin Layers Of 8 Cm Deep Before Laying The Cable And 15 Cm Deep After Laying And Stretching The Cable Complete All As Specified And As Directed.Note:- Measurement Shall Be Taken After Gentling Puning Of Sand. 21 Supply And Layingpcc Cable Cover Class Hv Type 1 Flat Size 300 Mmx180mmx40mm Complete All As Specified And As Directed. 22 Returning, Filling In Including Spreading, Levelling, Watering And Well Ramming Excavated Soil In Layers Not Exceeding 25 Cm Thick Each , Filling Back In Trenches After Cables Have Been Laid And Tested Complete All As Specified And As Directed. 23 Removal Of Excavated Surplus Soil To A Distance Not Exceeding 50 Mtr And Depositing Where Directed At A Level Not Exceeding 1.5 Metre Above The Starting Point Complete All Asspecified And As Directed. 24 Supply And Laying Gi Pipe Light Grade With All Fitting And Fixed Complete To Walls / Poles / Underpassand Ceilings Or Laid In Floors Complete All As Specified And As Directed. 25 50 Mm Bore 26 80 Mm Bore 27 100 Mm Bore 28 Supply And Laying Electrical Insulation Rubber Mating As Per Isi And Size 1Mx2mx25mm Thick Complete All As Specified And As Directed. 29 Supply And Laying Electrical Insulation Rubber Mating As Per Isi And Size 1Mx2mx20mm Thick Complete All As Specified And As Directed. 30 M&L For Earthing Complete With Galvanized Steel Earth Plate Electrodesize 600Mm X 600Mm X 6.0Mm Thick Buried Directly In Groundvertically In A Pit Of Depth Not Less Than 2.25 Mtr Below Ground Levels With Top Edge Of The Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level Surrounded From All Sides By Mixture Of Charcoal And Common Salt And Electrode Connected To Gi Earth Strip 32 X 6Mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Including Gi Protection Pipe Light Grade 40Mm Dia Connected To Main Earth Wire On Pole Or Control Board And Gi Pipe Medium Grade 20Mm Dia Bore For Watering Funnel With Wire Mesh. Rcc Cover With Concrete ( 1:2:4 ) Type B-1 Using 8Mm Bars @ 100Mm C / C Both Way With Frame, Pcc Chamber Pit With Pcc ( 1:3:6 ) Type C-2 Including Necessary Excavation And Earth Work All As Shown In Electrical Plate No 3 Connected To Earthing Test Point And Testing On Completion Including Taking Down Existing Earthing Complete All As Specified And As Directed.Note : The Unit Rate Includes For Protection Pipe And Gi Earth Strip 32 X 6Mm From Top Of Earth Plate Upto 7.5M Above Ground Level. 31 M&L For Earthing Complete With Galvanized Steel Earth Plate Electrodesize 600 Mm X 600 Mm X 6.3 Mm Thick Buried Directly In Groundvertically In A Pit Of Depth Not Less Than 2.25 Mtr Below Ground Levels With Top Edge Of The Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level Surrounded From All Sides By Mixture Of Charcoal And Common Salt And Electrode Connected To And Including Galvanized Iron Wire 4Mm As Earthing Lead By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Including Gi Protection Pipe Light Grade 15Mm Dia Connected To Main Earth Lead On Pole Or Control Board And Gi Pipe Light Grade 20 Mm Dia For Watering Funnel With Wire Mesh. Ci Cover With Frame, Pcc Chamber Pit With Pcc ( 1:3:6 ) Type C-2 Including Necessary Excavation And Earth Work All As Shown In Electrical Plate No 3 Connected To Earthing Test Point And Testing On Completion Complete All As Specified And As Directed.Note : Gi Wire And Protection Pipe Upto7.5 Mtr Length From Earth Electrode Shall Be Included In Quoted Rate Of Item. 32 M&L For Gi Strip Of Size 32X6mm As Earth Continuity Conductor Burried In Ground Or Drawn In Pipe Or Fixed To Wall On Saddle Complete All As Specified And As Directed. 33 Disconnecting The Electric Supply From Transformer, Openingthetop Cover Of 11 Kv / 0.433Kv Step Down Transformer Upto 500 Kva Capacity By Removing The Inspection Cover / Top Cover, Decanning Of The Transformer Oil Upto Required Level For Replacement Of Lt / Ht Bushfrom The Shell And Replacement For Burnt Out / Unserviceable Lt / Ht Bush, Studs And Gasket Of Buchholesto Avoid Leakge Of Oil, Refilling Of Oil Into The Transformer After Required Repair Works Complete All As Specified And As Directed. Note : ( I ) Ht / Lt Metal Studs, Ht / Lt Bushes And Gaskets Will Be Measured And Paid Seperately Under Respective Items Here-In After. ( Ii ) Replacement Of Unserviceable Bolts, Nuts And Washers Are Deemed Tobe Included In The Quoted Rate. 34 M&L For Painting Oftransformer Upto 500 Kva Including Connected Lt Bus Duct In The Transformer Room With Synthatic Enameled Grey Paint By Using Spray Gun Machine After Removing All Dust And Rust.And Writing Date Of Paintwith Blacksynthetic Enamel Paint Complete All As As Directed. 35 Supply And Filling Of Fresh Transformer Oil In Transformers Having Diaelectric Strength 45 Kv In 3 Mm Gap Including Testing Complete All As Specified And As Directed. 36 M&L For Purification, Filtration And Dehydration Of Transformer Oil From Transformer Installed At Various Indoor / Outdoor Sub Station By Ultra High Vaavvun Filtration Machine With Stream Line Filtration Plant At A Temp 60 To 70 Deg. Celsius And Achieving Minimum Dieectric Withstand Strength Of 60 Kv For 1 Minute In 2.5 Mm Gap Setting ( For Used Oil ) Complete All As Specified And As Directed. 37 Supply And Fix Digital Type Ammeter Of Size 96X96 Mm On Ht Panel As That Of Existing Range Model To Suit To Existing Ct Ratio 100 / 1A Including Taking Out Unserviceable One Connectiong Testing And Commissioning Complete All As Specified And As Directed. 38 Supply And Fix Digital Type Ammeter Of Size 96X96 Mm On Ht Panel As That Of Existing Range Model To Suit To Existing Ct Ratio 150 / 1A Including Taking Out Unserviceable One Connectiong Testing And Commissioning Complete All As Specified And As Directed. 39 Supply, Laying And Pasting On Floor Suitable For Hv 11Kv Synthetic Insulating Rubber Mat Of Size 2M X1m X 19Mm Class A Complete All As Specified And As Directed. 40 M&L For Cutting Wild Grass, Bushes, Creaper, Unwanted Vegetation And Trees Not Exceeding 30 Cm Girth ( Measured One Metre Above Ground Level ) And Removing Rubbish Upto A Distance Of 50 Metres Outside The Periphery Of The Area Under Clearance From Inside / Surrounding Of E / M Sub Station ( Transformers ) Including Cutting Creapers From Barbed / Cattle Fencing Of The Sub Stn As When Directed And Removing Of Unwanted Material From Installation Fencing / Compound And Depositing Where Directed After Taking Proper Electric Shutdown Form Mrs Mathura Complete All As Specified And As Directed.Note :- The Item Shall Be Operated Maximum Two Times In Entire Period Of Contract In The Same Installations And Area Measured Separately Each Time. 41 M&L For Taking Out Old Unserviceableht / Lt Coil Removing Insulation Complete By Brushing Coil, Cleaning The The Inner Body Complete Making Free From Dist And Dirt, All Impurities, Applying Paper Insulation ( Is Specified ) Of Transformer Complete Of Capacity 63 To 1000 Kva Complete All As Specified And As Directed. 42 M&L For Re-Winding Of Ht Coils With Super Enemelled Best Quality Copper Wire Of Existing Guage With Superior Quality Insulation Material For Transformer Of Capacity 63 To 1000 Kva Complete All As Specified And As Directed. 43 M&L For Re-Winding Of Lt Coils With Super Enemelled Best Quality Copper Wire Of Existing Guage With Superior Quality Insulation Material For Transformer Of Capacity 63 To 400 Kva Complete All As Specified And As Directed. 44 Supply And Fabrication Of Rigidly Welded Construction Duly Ribbed Bed Mild Steel Trolley Suitable For Mounting Transformer Step Down Outdoor Type Complete With Stranded Fittings Made Of Channel 200 X 75 Mm In Dimension 4100Mm X 2100 Mm Wide Mild Steel Chequered Plate 6 Mm Thick As Per Size Of Body With Four Intermediate Numbers Of Channels 125 X 65 Mm In Between Base Frame With Stand Hook And Three Side Openable Comprising The Following: ( A ) Tyre With Wheel Drum-04 Nos And Axle -Tree Of Suitable Size ( Part No 6.00-16 ) As Approved By Engineer In-Charge. ( B ) Leaf Spring 4 Tonne Capacity Axial Movement -04 Nos ( C ) Toeing System Made Out Of Mild Steel Channel 50 X 100 Mm With Spring & Hook. ( D ) Side Railing 65 Cm With Welded Mesh 25 X 50Mm Of 4 Mm Galvanized Iron Wire With Frame Work Of Angle Iron 40 X 40X 6Mm. ( E ) Painting With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Zinc Chrome Primer ( F ) System For Free Movement Of Tyres At 180 Degrees In The Toeing Direction Will Be Provided With Provision Of Mild Steel Plate, Brushing, Bearing System With Additional Channel Frame. 45 Supply And Fixing In Repair Transformer Breather Assembly Oil Seal Type Made Oftransparant Pvcbody Heavy Duty Filled With Good Quality Silica Gel Blue Colour Of Capacity 800 Grams Complete All As Specified And As Directed. 46 Supply And Fixing In Repairtransformer Breather Assembly Oil Seal Type Made Oftransparant Pvcbody Heavy Duty Filled With Good Quality Silica Gel Blue Colour Of Capacity 1200 Grams Complete All As Specified And As Directed. 47 M&L For Disconnecting Electrical Connections Of Step Down Transformers 11Kv / 0.433 Kv After Taking Proper Electric Shutdown Andlabour And T&P For Opening / Stripping Of The Same, Draining Out Oil In Clean Barrels, Lifting The Core & Coil Assembly, Washing And Cleaning Dust, Dirt & Sludge Deposit From All Parts, Cleaning And Polishing Of Tapping Contact Point, Making Internal Connections, Providing New Cork Sheet Gasket Packing 10 Mm Thick And Pouring In The Insulating Oil In The Transformer, Re-Assembling The Transformer After Repair Work, Checking For Any Leakages Including Replacement Of Any Unserviceable Parts Required To Make It Serviceable All As Directed And Placing The Transformer At Original Or Any Other Location And Making All Electric Connections Including Testing The Transformer To The Entire Satisfaction Of Engr-In-Charge Of Following Capacities. Note : ( I ) Spares Required For Replacement Of Unserviceable Parts Shall Be Measured And Paid Separately Under Relevant Item Of This Boq As Supply Only And Cost Of Labour Thereof Is Deemed To Be Included In Unit Rate Quoted. ( Ii ) Cost Of Transportation, Loading, Unloading From Sub Station To Workshop & Back Including Its Installation, Testing & Commissioning Complete Is Deemed To Be Included In Unit Rate Quoted. 48 50 Kva To 160 Kva 49 150 Kva To 250 Kva 50 300 Kva To 400 Kva 51 500 Kva To 630 Kva 52 Supply Only Lv Brass Stud Full Threaded With Required Nuts & Washer Suitable For 11Kv / 433V Distribution Transformer Of Following Capacites:- 53 50 Kva To 160 Kva 54 150 Kva To 250 Kva 55 300 Kva To 400 Kva 56 500 Kva To 630 Kva 57 Supply Only Hv Brass Stud Full Threaded With Required Nuts & Washer Suitable For 11Kv / 433V Distribution Transformer Of Following Capacites: 58 50 Kva To 160 Kva 59 150 Kva To 250 Kva 60 300 Kva To 400 Kva 61 500 Kva To 630 Kva 62 Supply Only Lv Bushing With Gasket Suitable For 11Kv / 433V Distribution Transformer Of Following Capacites:- 63 50 Kva To 160 Kva 64 150 Kva To 250 Kva 65 300 Kva To 400 Kva 66 500 Kva To 630 Kva 67 Supply Only Hv Bushing With Gasket And Arcing Horn Suitable For 11Kv / 433V Distribution Transformer Of Following Capacites:- 68 50 Kva To 160 Kva 69 150 Kva To 250 Kva 70 300 Kva To 400 Kva 71 500 Kva To 630 Kva 72 Replacement Of Old Unserviceable / Damaged Temperature Gauge With New Temperature Gauge Suitable For Transformer Of Any Capacity And Any Type Including All Necessary Accessories I.E. Nipple, Socket, Complete All As Specified And As Directed. 73 S&F Aluminium Lugs For The Following Sizes Complete All As Specified And Directed :- 74 25 To 70 Sqmm 75 95 To 120 Sqmm 76 150 To 185 Sqmm 77 185 To 240 Sqmm 78 300 To 400 Sqmm 79 Heat Shrinkable Pvc Sleeve Suitable For Xlpe Lt Ug Cable Fo Following Sizes Complete:- 80 119 Sqmm To 300 Sqmm. 81 120 Sqmm To 300 Sqmm. 82 Supply And Fixing In Replacement Selector Switch As Per Sample Or As Directed. 83 Disconnecting And Taking Down Ht Ug Cable From Ht Pole / Transformer And Cutting Faulty End Portion Of The Cable, Dressing Properly And Making Good End Termination, Outdoor Type With And Including Suitable Size Of Heat Shrinkable New Jointing Kit 11000 Volts Grade And Aluminum Lugs Duly Crimped With Crimping Tool For The Following Sizes Of Ht Cables:- 84 95 Sqmm 3 Core. 85 120 Sqmm To 300 Sqmm 3 Core. 86 Disconnecting And Taking Down Ht Ug Cable From Ht Pole / Transformer And Cutting Faulty End Portion Of The Cable, Dressing Properly And Making Good End Termination, Indoor Type With And Including Suitable Size Of Heat Shrinkable New Jointing Kit 11000 Volts Grade And Aluminum Lugs Duly Crimped With Crimping Tool For The Following Sizes Of Ht Cables:- 87 95 Sqmm 3 Core. 88 120 Sqmm To 185 Sqmm 3 Core. 89 Supply And Jointing Ht Cable With Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Straight Through Heat Shrinkable Type Joint With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminum Conductor Cable Of Following Sizes Of Ht Cables:- 90 95 Sqmm 3 Core. 91 120 Sqmm To 185 Sqmm 3 Core. 92 M&L For Painting Of Steel Tubular Ht / Lt Pole 11 Mtr Including Cross Arms, Clamps, Back Plates Etc In Situ With One Under Coat And One Finishing Coat Of Aluminum Paint After Cleaning / Preparation Of Surfaces Including Making Yellow And Black Strips 30 Cm Wide 5 Nos With Two Coats Of Synthetic Enamel Paint Complete All As Specified And As Directed. 93 All As Per Item No 56.00 Here-In-Before But For 2 Pole Structure Including Bracings Complete All As Specified And As Directed. 94 All As Per Item No 56.00 Here-In-Before But For 4 Pole Structure Including Bracings Complete All As Specified And As Directed. 95 Supply And Fixing In Replacement Of Mccb 630Amp Rating ( Ics = 100% Of Icu ) , 4-Pole 415V, Electronic Release With Overload And Short Circuit Adjustable Type Breaking Capacity 50 Ka Complete All As Specified And As Directed. 96 Supply Andfixing In Replacement Of Mccb 400Amp Rating ( Ics = 100% Of Icu ) , 4-Pole 415V, Adjustable Thermal Adjustable Megnetic Type Breaking Capacity 50 Ka Complete All As Specified And As Directed. 97 Supply Andfixing In Replacement Of Mccb 250Amp Rating ( Ics = 100% Of Icu ) , 4-Pole 415V, Adjustable Thermal Adjustable Megnetic Type Breaking Capacity 35Ka Complete All As Specified And As Directed. 98 Supply Andfixing Inreplacement Of Mccb 100Amp Rating ( Ics = 100% Of Icu ) , 4-Pole 415V, Adjustable Thermal Adjustable Megnetic Typeadjustable Thermal Adjustable Megnetic Type Breaking Capacity 16Ka Complete All As Specified And As Directed. 99 Supply Andfixing Inreplacement Of Mccb 250Amp Rating ( Ics = 100% Of Icu ) , 3-Pole 415V, Adjustable Thermal Adjustable Megnetic Typebreaking Capacity 35Ka Complete All As Specified And As Directed. 100 Supply Andfixing In Replacement Of Mccb 200Amp Rating ( Ics = 100% Of Icu ) , 3-Pole 415V, Adjustable Thermal Adjustable Megnetic Typebreaking Capacity 35Ka Complete All As Specified And As Directed. 101 Material And Labour For Repair / Overhauling Of Off Load Tap Changer Of Step Down Transformer 11Kv / 433V Including Connection Complete All As Specifieid And As Directed. 102 M&L For Making Of Surface For Painting Duly Scrubing The Existing Paint And Apply Of Two Coats Of Existing Synthetic Enamel Paint Over A Coat Of Red Oxide Primer For Lt Panel Board / Feeder Piller Box Of Any Size / Type At Various Location Complete All As Specified And As Directed. 103 M& L Forwelding Works To Lt Panel / Bus Bar / Feeder Pillar Box For Fixing Hinges, Locking Arrangement Or Reapir Pitted Area Etc At Site Complete All As Specified And As Directed. 104 Supply And Fixing Cable Tray Suitable For Supporting And Carrying Out Lt Cable Upto Transformer Of Size Upto 300 Sqmm Complete All As Directed. 105 Supply And Fixing In Replacement Of Aluminium Bus Bar Of Capacity200 Amp Suitable For Lt Panels / Bus Bars / Feeder Pillar Box, Rectangular Shape And As Per Existingdesign Etcincluding Nut, Bolt, Complete All As Specified And As Directed. 106 Supply And Fixing In Replacement Of Aluminium Bus Bar Of Capacity 400 Amp Suitable For Lt Panels / Bus Bars / Feeder Pillar Box, Rectangular Shape And As Per Existingdesign Etcincluding Nut, Bolt, Complete All As Specified And As Directed. 107 Supply And Fixing In Replacement Of Aluminium Bus Bar Of Capacity 600 Amp Suitable For Lt Panels / Bus Bars / Feeder Pillar Box, Rectangular Shape And As Per Existingdesign Etcincluding Nut, Bolt, Complete All As Specified And As Directed. 108 Supply And Fixing After Disconnected Of Electric Supply To Vcb And Replace The Unserviceable Over Current And Earth Fault Protection Relay, Vx=24 -240 V Ac / 24-250 V Dc, In=1A / 5A ( 0, 1In-40In ) , Ion=1 A / 5A ( 0, 01Ion-2Lon ) Complte All As Specified And As Directed.Note:- Fixing Of Protection Relay Shall Be Carried Out Through O.E.M Of MaanufacturerS Engineer / Technician Only. 109 S&F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As Per Is 15965: 2012 In Roof Covering / Cladding To Wall With Self Tapping Screws Complete All As Specified And As Directed. 110 M&L For Framed Work As In Ms Sheet Section, Hinges, Angle Iron Etc Complete Confirming To Fe-410-O Or Fe 310-0 Complete All As Specified And As Directed. 111 Supply And Fixing In Replacement Of Spreader Terminal For Mccb In Lt Panel / Feeder Pillar Boxsuitable For Rating 80 Amp To 100 Amp , 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 112 Supply And Fixing In Replacement Of Spreader Terminal For Mccb In Lt Panel / Feeder Pillar Boxsuitable For Rating 125 Amp To 200 Amp , 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 113 Supply And Fixing In Replacement Of Spreader Terminal For Mccb In Lt Panel / Feeder Pillar Boxsuitable For Rating 200 Amp To 400 Amp , 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 114 Supply And Fixing In Replacement Of Spreader Terminal For Mccb In Lt Panel / Feeder Pillar Boxsuitable For Rating 500 Amp To 630 Amp , 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 115 M&L For Carrying Out Calibration Of Air Circuit Breaker 630 Amp To 1000 Amps, Over Fault Relay, Earth Fault Relay, Checking Of Alignment Of Acb Isolating Contacts, Servicing Of Electronic Operating Mechanism Including Tripping And Closing System Of The Breakers, Dehydrating, Decorbonising Of Panel, Bus Section & Circuit Section. Removing Perished Monoplus Compound Cleaning And Re-Insulating With Lt Taps Wherever Necessary , Also Supply And Fixing Outdoor / Indoor Type Acb Mounting Panel Conopy As Per Suitable Size 2.00 Mm Thick Crca Sheet , Front And Back Opening And Locking Arrangement Of Acb Mechanism, With Fixing Arrangement At Foundation And Including Repalcement Of Minor Items Like Nuts, Bolts, Washer Etc Of Authorised Dealer / Representative And Refixing The Acb Breaker In Its Original Position And Testing Entire Satisfaction Of Engineer-In-Charge.Note : ( I ) The Major Spare Parts Measeured And Paid Separetely Against Items At Boq. 116 Supply And Fixing In Replacement Of Spring Charging Motor Capacity 110 / 230 Voltsuitable For Acb Capacity Upto 800 Amp, 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 117 Supply Only Shunt Trip Coil Suitable For Acb Capacity Upto 800 Amp, 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 118 Supply Only Under Voltage Trip Device Suitable For Acb Capacity Upto 800 Amp, 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 119 Supply Only Adapter Type Terminal Suitable For Acb Capacity Upto 800 Amp, 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 120 Supply Onlyin Replacement Of Spring Charge Indication Switch Suitable For Acb Capacity Upto 800 Amp, 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 121 Supply Only Trip Indication Switch Suitable For Acb Capacity Upto 800 Amp, 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 122 Supply Only Position Indication Switch Suitable For Acb Capacity Upto 800 Amp, 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 123 Supply Onlyon / Off Push Button Suitable For Acb Capacity Upto 800 Amp, 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 124 Supply Onlyon / Off Neutral Ct Suitable For Acb Capacity Upto 800 Amp, 4 Pole, 50 Hz, Ac Complete All As Specified And As Directed. 125 Supplying And Fixing In Replacement Of Existing Lt Feeder Pillar Box Out Door Type Of Size 60Cmx60cmx40cm Made Out Of Ms Sheet Of 3.15 Mm Thick With Alluminium Busbar, Duly Powder Coated & Mounted On Angle Iron Frame Made Out Of Size 50X50x6mm, 90 Cm High Consisting Of The Following Accessories And Make As Approved By Ge From Approved List: ( A ) Mccb Tpn 415 Volts 200 Amp. 25 Ka Adjustable Type -- 01 Nos ( For Incoming ) Complete. ( B ) Aluminium Bus Bar 200 Amp For Three Phase And 100 Amp Neutral Complete. ( C ) Digital Volt Meter With Selecter Switch-01 Nos Complete ( D ) Digital Voltmeter Ameter And On / Off Switch-01 Nos Complete 126 Supplying And Fixing In Replacement Of Feeder Pillar Box Out Door Type Made Out Of Ms Sheet Of 3.15 Mm Thick With Alluminium Busbar, Duly Powder Coated & Mounted On Angle Iron Frame Made Out Of Size 50X50x6mm, 90 Cm High Consisting Of The Following Accessories And Make As Approved By Ge From Approved List:- ( A ) Mccb Tpn 415 Volts 250 Amp. 36 Ka Adjustable Type ---01 Nos ( For Incoming ) ( B ) Mccb Tpn 415 Volts 63Amp. 16 Ka Adjustable Type ---04 Nos ( For Outgoing ) Complete ( C ) Mccb Tpn 415 Volts 160Amp. 25 Ka Adjustable Type ---01 Nos ( For Outgoing ) Complete. ( D ) Led Indicating Lamp Cluster Type Set Of Three Colour In Red / Blue / Green- 01 Sets Complete. ( E ) Digital Multifunction Meter With Volmeter ( 0-500V ) , Ampmeter ( 0-250 ) & Frequency Meter- 01 Nos Complete. ( G ) Grouting Of Panel 60Cm Above Gl, Embedded In Pcc ( 1:2:4 ) Using 20 Mm Graded Stone Aggregate Up To 30 Cm Complete.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Dec-2022 AMENDMENT BOQ 02-01-2023
2 02-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-

BOQ Items

Name of Work:REPAIR MAINTENANCE OF ELECTRICAL EQUIPTMENT AND ALLIED WORKS UNDER GE (EAST) MATHURA
Sl. No. Item Description
1Dismantling steel tubular poles of any size complete all as specified and as directed.
2Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers as per IS 2713 (Part-II) 1980 made out of mild steel tubing, type 410 SP-55 (11.00 metre long) including marking pole No on pole including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and as directed. Note : Earth work and PCC in foundation shall be measured separately.
3Supply, installing and testing of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp capacity suitablefor 11 KV complete all as specified and as directed.
4M&L for fixing air break gang operated switch outdoor type HT 11 KV triple pole mechanically operated mounted on HT insulators horizontal/ vertical typeincluding MS galvanised steel frame with operating mechanism worked from ground level including operating rod of size 32 mm dia GI medium grade for current rating of cap 400 Amps 11000 volts with locking arrangement, MS clamps, bolts, nuts and washers etc including preparation of MS surface and applying two coats of aluminum paint over a coat of red oxide primercomplete all as specified and as directed.
5Supply and Fixing drop Out Fuse unit,expulsion type for outdoor air break gang operated switch,single pole,mounted on and including insulators for 11 KV working pressure fixed to and including MS channels with nuts,bolts & washers etc,synthetic bounded fuse tube complete suitable for current carrying capacity upto 100 Amps complete all as specified and as directed.
6Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and nexc 1.5 m in depth and getting out complete all as specified and as directed.
7Excavating in trenches, n exc 1.5 m wide and more than 1.5 m n exc 3.0 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and nexc 3.0 m in depth and getting out complete all as specified and as directed.
8M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
9M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundationfilling and mass concrete complete all as specified and as directed.
10M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping complete all as specified and as directed.
11M&L for Cable route indicator showing "HT Cable" and route/joint of cable with arrow made of PCC 1X2X4 type B1 duly rendered with plaster 10 mm thick of size 40 x 50 x 20cm fixed and erected on PCC plateform of sixe 40 x 40 x 10 CM goruted in grounts duly painted on both sides with HT Cable Route complete all as specified and as directed.
12Dismantling unserviceable cross arms, clamps etc and removing from site complete all as specified and as directed.
13M&L for work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed.
14Disconnecting and taking out existing unserviceable defective HT cable any size any type from trenches/duct/ poles including taking out old bricks complete all as specified and as directed.
15Supply laying & testingXLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000V grade, of cross section area95 sq mm 3 core complete all as specified and as directed.
16Supply laying & testingXLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000V grade, of cross section area120 sq mm 3 core complete all as specified and as directed.
17Supply laying & testingXLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor, 11000V grade, of cross section area150 sq mm 3 core complete all as specified and as directed.
18Supply laying & testingXLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000V grade, of cross section area185 sq mm 3 core complete all as specified and as directed.
19Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out in soft/loose soil complete all as specified and as directed.
20M&L for sand cushioning to under ground cable in trenchesin layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and as directed. Note:- Measurement shall be taken after gentling puning of sand.
21Supply and layingPCC cable cover class HV type 1 flat size 300 mmx180mmx40mm complete all as specified and as directed.
22Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and as directed.
23Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all asspecified and as directed.
24Supply and laying GI Pipe light grade with all fitting and fixed complete to walls/poles/underpassand ceilings or laid in floors complete all as specified and as directed.
2550 mm bore
2680 mm bore
27100 mm bore
28Supply and laying electrical insulation rubber mating as per ISI and size 1mx2mx25mm thick complete all as specified and as directed.
29Supply and laying electrical insulation rubber mating as per ISI and size 1mx2mx20mm thick complete all as specified and as directed.
30M&L for earthing complete with galvanized steel earth plate electrodesize 600mm x 600mm x 6.0mm thick buried directly in groundvertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to GI earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth wire on pole or control board and GI pipe medium grade 20mm dia bore for watering funnel with wire mesh. RCC cover with concrete (1:2:4) type B-1 using 8mm bars @ 100mm C/C both way with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion including taking down existing earthing complete all as specified and as directed. Note : The unit rate includes for protection pipe and GI Earth strip 32 x 6mm from top of earth plate upto 7.5m above ground level.
31M&L for earthing complete with galvanized steel earth plate electrodesize 600 mm x 600 mm x 6.3 mm thick buried directly in groundvertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified and as directed. Note : GI wire and protection pipe upto7.5 Mtr length from earth electrode shall be included in quoted rate of item.
32M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed.
33Disconnecting the electric supply from transformer, openingthetop cover of 11 KV/0.433KV step down transformer upto 500 KVA capacity by removing the inspection cover/top cover, decanning of the transformer oil upto required level for replacement of LT/HT bushfrom the shell and replacement for burnt out/ unserviceable LT/HT bush, studs and gasket of buchholesto avoid leakge of oil,refilling of oil into the transformer after required repair works complete all as specified and as directed. Note : (i)HT /LT metal studs, HT/LT bushes and gaskets will be measured and paid seperately under respective items here-in after. (ii) Replacement of unserviceable bolts, nuts and washers are deemed tobe included in the quoted rate.
34M&L for painting oftransformer upto 500 KVA including connected LT bus duct in the transformer room with synthatic enameled grey paint by using spray gun machine after removing all dust and rust.and writing date of paintwith blacksynthetic enamel paint complete all as as directed.
35Supply and filling of fresh transformer oil in transformers having diaelectric strength 45 KV in 3 mm gap including testing complete all as specified and as directed.
36M&L for purification, filtration and dehydration of transformer oil from transformer installed at various indoor/outdoor sub station by ultra high vaavvun filtration machine with stream line filtration plant at a temp 60 to 70 deg. celsius and achieving minimum dieectric withstand strength of 60 KV for 1 minute in 2.5 mm gap setting (for used oil) complete all as specified and as directed.
37Supply and fix digital type Ammeter of size 96X96 mm on HT panel as that of existing range model to suit to existing CT ratio 100/1A including taking out unserviceable one connectiong testing and commissioning complete all as specified and as directed.
38Supply and fix digital type Ammeter of size 96X96 mm on HT panel as that of existing range model to suit to existing CT ratio 150/1A including taking out unserviceable one connectiong testing and commissioning complete all as specified and as directed.
39Supply, laying and pasting on floor suitable for HV 11KV synthetic insulating rubber mat of size 2m x1m x 19mm class A complete all as specified and as directed.
40M&L for cutting wild grass, bushes, creaper, unwanted vegetation and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance from inside / surrounding of E/M sub station (transformers) including cutting creapers from barbed / cattle fencing of the sub stn as when directed and removing of unwanted material from installation fencing/compound and depositing where directed after taking proper electric shutdown form MRS Mathura complete all as specified and as directed. Note :- The item shall be operated maximum two times in entire period of contract in the same installations and area measured separately each time.
41M&L for taking out old unserviceableHT/LT coil removing insulation complete by brushing coil,cleaning the the inner body complete making free from dist and dirt,all impurities, applying paper insulation(IS specified) of transformer complete of capacity 63 to 1000 KVA complete all as specified and as directed.
42M&L for re-winding of HT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity 63 to 1000 KVA complete all as specified and as directed.
43M&L for re-winding of LT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity 63 to 400 KVA complete all as specified and as directed.
44Supply and fabrication of rigidly welded construction duly ribbed bed mild steel trolley suitable for mounting transformer step down outdoor type complete with stranded fittings made of channel 200 x 75 mm in dimension 4100mm x 2100 mm wide mild steel chequered plate 6 mm thick as per size of body with four intermediate numbers of channels 125 x 65 mm in between base frame with stand hook and three side openable comprising the following: (a) Tyre with wheel drum-04 nos and axle -tree of suitable size (part no 6.00-16) as approved by engineer in-charge. (b) Leaf spring 4 tonne capacity axial movement -04 nos (c) Toeing system made out of mild steel channel 50 x 100 mm with spring & hook. (d) Side railing 65 cm with welded mesh 25 x 50mm of 4 mm galvanized iron wire with frame work of angle iron 40 x 40x 6mm. (e) Painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (f) System for free movement of tyres at 180 degrees in the toeing direction will be provided with provision of mild steel plate, brushing,bearing system with additional channel frame.
45Supply and fixing in repair transformer breather assembly oil seal type made oftransparant PVCbody heavy duty filled with good quality silica gel blue colour of capacity 800 grams complete all as specified and as directed.
46Supply and fixing in repairtransformer breather assembly oil seal type made oftransparant PVCbody heavy duty filled with good quality silica gel blue colour of capacity 1200 grams complete all as specified and as directed.
47M&L for disconnecting electrical connections of step down transformers 11KV/0.433 KV after taking proper electric shutdown andlabour and T&P for opening/stripping of the same, draining out oil in clean barrels, lifting the core & coil assembly, washing and cleaning dust, dirt & sludge deposit from all parts, cleaning and polishing of tapping contact point, making internal connections, providing new cork sheet gasket packing 10 mm thick and pouring in the insulating oil in the transformer, re-assembling the transformer after repair work, checking for any leakages including replacement of any unserviceable parts required to make it serviceable all as directed and placing the transformer at original or any other location and making all electric connections including testing the transformer to the entire satisfaction of Engr-in-Charge of following capacities. Note : (i) Spares required for replacement of unserviceable parts shall be measured and paid separately under relevant item of this BOQ as supply only and cost of labour thereof is deemed to be included in unit rate quoted. (ii)Cost of transportation, loading, unloading from sub station to workshop & back including its installation, testing & commissioning complete is deemed to be included in unit rate quoted.
4850 KVA to 160 KVA
49150 KVA to 250 KVA
50300 KVA to 400 KVA
51500 KVA to 630 KVA
52Supply only LV brass stud full threaded with required nuts & washer suitable for 11KV/433V distribution transformer of following capacites:-
5350 KVA to 160 KVA
54150 KVA to 250 KVA
55300 KVA to 400 KVA
56500 KVA to 630 KVA
57Supply only HV brass stud full threaded with required nuts & washer suitable for 11KV/433V distribution transformer of following capacites:
5850 KVA to 160 KVA
59150 KVA to 250 KVA
60300 KVA to 400 KVA
61500 KVA to 630 KVA
62Supply only LV bushing with gasket suitable for 11KV/433V distribution transformer of following capacites:-
6350 KVA to 160 KVA
64150 KVA to 250 KVA
65300 KVA to 400 KVA
66500 KVA to 630 KVA
67Supply only HV bushing with gasket and arcing horn suitable for 11KV/433V distribution transformer of following capacites:-
6850 KVA to 160 KVA
69150 KVA to 250 KVA
70300 KVA to 400 KVA
71500 KVA to 630 KVA
72Replacement of old unserviceable/damaged temperature gauge with new temperature gauge suitable for transformer of any capacity and any type including all necessary accessories i.e. nipple, socket, complete all as specified and as directed.
73S&F aluminium lugs for the following sizes complete all as specified and directed :-
7425 to 70 Sqmm
7595 to 120 Sqmm
76150 to 185 Sqmm
77185 to 240 Sqmm
78300 to 400 Sqmm
79Heat shrinkable PVC sleeve suitable for XLPE LT UG cable fo following sizes complete:-
80119 sqmm to 300 Sqmm.
81120 sqmm to 300 Sqmm.
82Supply and fixing in replacement selector switch as per sample or as directed.
83Disconnecting and taking down HT UG cable from HT pole/ transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, outdoor type with and including suitable size of heat shrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables:-
8495 Sqmm 3 core.
85120 Sqmm to 300 Sqmm 3 core.
86Disconnecting and taking down HT UG cable from HT pole/ transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, Indoor type with and including suitable size of heat shrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables:-
8795 Sqmm 3 core.
88120 Sqmm to 185 Sqmm 3 core.
89Supply and jointing HT cable with jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of following sizes of HT cables:-
9095 Sqmm 3 core.
91120 Sqmm to 185 Sqmm 3 core.
92M&L for painting of steel tubular HT/LT pole 11 mtr including cross arms, clamps, back plates etc in situ with one under coat and one finishing coat of aluminum paint after cleaning/ preparation of surfaces including making yellow and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint complete all as specified and as directed.
93All as per item No 56.00 here-in-before but for 2 pole structure including bracings complete all as specified and as directed.
94All as per item No 56.00 here-in-before but for 4 pole structure including bracings complete all as specified and as directed.
95Supply and fixing in replacement of MCCB 630Amp rating (Ics = 100% of Icu), 4-pole 415V, Electronic release with overload and short circuit adjustable type breaking capacity 50 KA complete all as specified and as directed.
96Supply andfixing in replacement of MCCB 400Amp rating (Ics = 100% of Icu),4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 50 KA complete all as specified and as directed.
97Supply andfixing in replacement of MCCB 250Amp rating (Ics = 100% of Icu),4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA complete all as specified and as directed.
98Supply andfixing inreplacement of MCCB 100Amp rating (Ics = 100% of Icu),4-pole 415V, adjustable thermal adjustable megnetic typeadjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
99Supply andfixing inreplacement of MCCB 250Amp rating (Ics = 100% of Icu),3-pole 415V, adjustable thermal adjustable megnetic typebreaking capacity 35KA complete all as specified and as directed.
100Supply andfixing in replacement of MCCB 200Amp rating (Ics = 100% of Icu),3-pole 415V, adjustable thermal adjustable megnetic typebreaking capacity 35KA complete all as specified and as directed.
101Material and labour for repair/overhauling of off load tap changer of step down transformer 11kv/433V including connection complete all as specifieid and as directed.
102M&L for making of surface for painting duly scrubing the existing paint and apply of two coats of existing synthetic enamel paint over a coat of red oxide primer for LT panel board/Feeder piller box of any size/type at various location complete all as specified and as directed.
103M& L forwelding works to LT Panel/Bus Bar/Feeder pillar box for fixing hinges, locking arrangement or reapir pitted area etc at site complete all as specified and as directed.
104Supply and fixing cable tray suitable for supporting and carrying out LT cable upto transformer of size upto 300 sqmm complete all as directed.
105Supply and Fixing in replacement of Aluminium Bus Bar of capacity200 Amp suitable for LT panels/ Bus bars/Feeder pillar box, rectangular shape and as per existingdesign etcincluding nut, bolt, complete all as specified and as directed.
106Supply and Fixing in replacement of Aluminium Bus Bar of capacity 400 Amp suitable for LT panels/ Bus bars/Feeder pillar box, rectangular shape and as per existingdesign etcincluding nut,bolt,complete all as specified and as directed.
107Supply and Fixing in replacement of Aluminium Bus Bar of capacity 600 Amp suitable for LT panels/ Bus bars/Feeder pillar box, rectangular shape and as per existingdesign etcincluding nut,bolt,complete all as specified and as directed.
108Supply and fixing after disconnected of electric supply to VCB and replace the unserviceable Over current and earth fault protection relay, Vx=24 -240 V AC/24-250 V DC,In=1A/5A(0,1In-40In), Ion=1 A/5A(0,01Ion-2Lon) complte all as specified and as directed. Note:- Fixing of protection relay shall be carried out through O.E.M of maanufacturer"s engineer/technician only.
109S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in roof covering /cladding to wall with self tapping screws complete all as specified and as directed.
110M&L for framed work as in MS sheet section,hinges, angle iron etc complete confirming to Fe-410-O or Fe 310-0 complete all as specified and as directed.
111Supply and Fixing in replacement of spreader terminal for MCCB in LT panel/Feeder pillar boxsuitable for rating 80 Amp to 100 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
112Supply and Fixing in replacement of spreader terminal for MCCB in LT panel/Feeder pillar boxsuitable for rating 125 Amp to 200 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
113Supply and Fixing in replacement of spreader terminal for MCCB in LT panel/Feeder pillar boxsuitable for rating 200 Amp to 400 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
114Supply and Fixing in replacement of spreader terminal for MCCB in LT panel/Feeder pillar boxsuitable for rating 500 Amp to 630 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
115M&L for carrying out calibration of Air Circuit Breaker 630 Amp to 1000 Amps,over fault relay,earth fault relay,checking of alignment of ACB isolating contacts,servicing of electronic operating mechanism including tripping and closing system of the breakers,dehydrating,decorbonising of panel,bus section & circuit section. Removing perished monoplus compound cleaning and re-insulating with LT taps wherever necessary , also supply and fixing Outdoor/indoor type ACB mounting panel conopy as per suitable size 2.00 mm thick CRCA sheet ,front and back opening and locking arrangement of ACB mechanism, with fixing arrangement at foundation and including repalcement of minor items like nuts,bolts,washer etc of authorised dealer/representative and refixing the ACB breaker in its original position and testing entire satisfaction of Engineer-in-charge.Note : (i) The major spare parts measeured and paid separetely against items at BOQ.
116Supply and Fixing in replacement of spring charging motor capacity 110/230 Voltsuitable for ACB capacity upto 800 Amp,4 pole,50 HZ,AC complete all as specified and as directed.
117Supply only shunt trip coil suitable for ACB capacity upto 800 Amp,4 pole,50 HZ,AC complete all as specified and as directed.
118Supply only under voltage trip device suitable for ACB capacity upto 800 Amp,4 pole,50 HZ,AC complete all as specified and as directed.
119Supply only Adapter type terminal suitable for ACB capacity upto 800 Amp,4 pole,50 HZ,AC complete all as specified and as directed.
120Supply onlyin replacement of Spring charge indication switch suitable for ACB capacity upto 800 Amp,4 pole,50 HZ,AC complete all as specified and as directed.
121Supply only trip indication switch suitable for ACB capacity upto 800 Amp,4 pole,50 HZ,AC complete all as specified and as directed.
122Supply only position indication switch suitable for ACB capacity upto 800 Amp,4 pole,50 HZ,AC complete all as specified and as directed.
123Supply onlyon/off push button suitable for ACB capacity upto 800 Amp,4 pole,50 HZ,AC complete all as specified and as directed.
124Supply onlyon/off neutral CT suitable for ACB capacity upto 800 Amp,4 pole,50 HZ,AC complete all as specified and as directed.
125Supplying and fixing in replacement of existing LT feeder pillar box out door type of size 60cmx60cmx40cm made out of MS sheet of 3.15 mm thick with alluminium busbar, duly powder coated & mounted on angle iron frame made out of size 50x50x6mm, 90 cm high consisting of the following accessories and make as approved by GE from approved list: (a) MCCB TPN 415 volts 200 Amp. 25 KA adjustable type -- 01 Nos (for incoming) complete. (b) Aluminium bus bar 200 Amp for three phase and 100 Amp neutral complete. (c) Digital volt meter with selecter switch-01 Nos complete (d) Digital voltmeter ameter and On/Off switch-01 Nos complete
126Supplying and fixing in replacement of feeder pillar box out door type made out of MS sheet of 3.15 mm thick with alluminium busbar, duly powder coated & mounted on angle iron frame made out of size 50x50x6mm, 90 cm high consisting of the following accessories and make as approved by GE from approved list:- (a) MCCB TPN 415 volts 250 Amp. 36 KA adjustable type ---01 Nos (For incoming) (b) MCCB TPN 415 volts 63Amp. 16 KA adjustable type ---04 Nos (for outgoing) complete (c) MCCB TPN 415 volts 160Amp. 25 KA adjustable type ---01 Nos (for outgoing) complete. (d) LED indicating lamp cluster type set of three colour in RED/BLUE/ GREEN- 01 Sets complete. (e) Digital multifunction meter with volmeter (0-500V), Ampmeter (0-250) & frequency meter- 01 Nos complete. (g) Grouting of panel 60cm above GL, embedded in PCC (1:2:4) using 20 mm graded stone aggregate up to 30 cm complete.