Tender For Electrical Installation Works For ( Gplus3 ) Model For Single 50 Bedded Covid Ward At Jhalda Rural Hospital, In The District Of Purulia----Supply Installation Testing And Commissioning Of Ups System.
Tender Overview
Project Description
Tender For Electrical Installation Works For ( Gplus3 ) Model For Single 50 Bedded Covid Ward At Jhalda Rural Hospital, In The District Of Purulia----Supply Installation Testing And Commissioning Of Ups System.
BOQ
| Sl. No. | Item Description |
| 1 | Topology, IGBT BASED DSP CONTROLED |
| 2 | Rating of UPS(KVA/KW): 20 KVA / 16KW (Make:switching AVO,Legrand,Emerson,Schneider,PowerOne, APC) |
| 3 | Input Voltage: 310----400----415 VAC 165-288 Volt /Phase(selectble) |
| 4 | Input Frequency: 45 to 65 Hz |
| 5 | Isolation Transformer:Inbuilt Isolation Transformer with 1:1 ratio at UPS Input to be provided at output |
| 6 | Back feed Protection: UPS should have back feed protection |
| 7 | Charging: Autometic float cum Boots Charging Capability with setteble flote & boost charging voltages and current levels and boots charger timer |
| 8 | Output Voltage: 230 VAC |
| 9 | Output Voltage Regulation: Static Variation +/_ 1% and Dynamic variation +/-3% |
| 10 | Output Frequency: 50 Hz +/- 0.1% |
| 11 | Output Power Factor: 0.8 |
| 12 | Crest Factor: 3:1 |
| 13 | THDu: < 2% (linear load), < 5%(non linear load) |
| 14 | Waveform: Pure Sine Wave |
| 15 | Birdge: Microprocessor based and IGBT Technology |
| 16 | Overload: 110% for 60 minutes,125% for 10 minutes, 150% for 30 sec |
| 17 | Static By Pass: 100 % rated static switches with fuse protection overload on Bypass: 100% for 10 ms |
| 18 | Overall Efficiency:92% |
| 19 | BattaryRack: With power coated MS angle with suiteble dimention and gadge.Useing Nyvin cable with proper rating for interlink cables and battery input and necessary acessiress. |
| 20 | Battery : 12 V, Mono Block batteries. SMF VRLA |
| 21 | DC Bus : Minimum 192V or above, 30 mim back up required(Minimum 28666VAH)Battery. Battery Make: Exide/Amar Raja(Quanta) |
| 22 | Protection:Multi Protection-Over Temperature Protection with 8 Sensors, Overload, Battery Under Voltage, Fan Failures ,Short Circuit.Four Circuit Breakers, Providing Full Protection When Fault, Strong Overload Capability. Surge Protector at Panel Input & EB Input.PV Reverse Polarity, Input Low & High Voltage, Output Low & High Voltage cut off. Glass cartridge Fuse on Control Circuits MCB at Input Panel, |
| 23 | Audio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter Trip |
| 24 | Metering:Graphical LCD display for Input & Output - Voltage, Current& Frequency, Battery - Voltage & Current |
| 25 | Indications:Mains - On / Fail / High / Low / Single PhasingDC - On / High,Battery - Low Pre-alarm / Low TripInverter - On / Trip / High / Low / Over Current |
| 26 | Switchgear: MCB / MCCB for Input, Battery, Output & Manual Bypass Switch |
| 27 | Termination: Input, Battery, Output & Bypass |
| 28 | Enclosure: IP 20 |
| 29 | Operating Temp: 0 to 40 Deg C |
| 30 | Humidity: Upto 95% Rh (non-condensing) |
| 31 | Cooling: Forced Air |
| 32 | Noise: < 55 dB |
| 33 | Cold Start : Provided |
| 34 | CE Certification:IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950 (Safety) IEC/EN 50091-2, IEC/EN 62040-2(EMC Emmission),IEC/EN 62040-3(performance & Design)IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146 (Design & Manufacture) |
| 35 | ISO 9001: 2015, ISO 14001: 2015, ISO 45001:2018,ISO 50001;2018 , ISO:20000-1:2011,ISO:27001:2013, ROHS |
| 36 | Warranty:One Year on UPS & two yers on batteries on site against any Manufacturing defects |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender