Tender For Repair And Maintenance Of Street Lights, Automatic Timer Switch, Pole Painting, Lightening Conductor, Dg Sets, Change Over And Allied Wks At Pedong, Algarah, Ap Algarah, Dalapchand, Teesta Tcp, Rhenock And Rongli Under Ge 867 Ews
Tender Overview
Project Description
Tender For Repair And Maintenance Of Street Lights, Automatic Timer Switch, Pole Painting, Lightening Conductor, Dg Sets, Change Over And Allied Wks At Pedong, Algarah, Ap Algarah, Dalapchand, Teesta Tcp, Rhenock And Rongli Under Ge 867 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Taking down unserviceable fitting of any type or any wattage i.e. 100/90/80/72/60/45/30/25 Watt energy efficient street light fitting, identifying the fault, repair / replacement of old unserviceable accessories with newaccessories, reassembling and make the street light fitting functional and refixing in existinglocation including three core copper PVC insulated conductorof 1 sqmm size (nominal area) of suitable length to connect the lumaniries to overhead conductor / existing lines complete all as specified and directed. Note : Spares part/material required for repair to street light fitting shall be measued and paid separtely under relevent items as supply only. |
| 2 | Supply only 1100 volts grade heavy duty cable PVC insulated and FR PVC rounded sheathed, copper conductor(flexible) industrial cable, conforming IS: 694 of size 1.5 sqmm 3 core laid along pole from junction box to light fittingcomplete all as specified and directed. |
| 3 | Supply only in replacement of street light driver of 25 watt to 50 watt, 230V,50Hz suitable foroperation over voltage range of 140V to 270V by emoving from existing positioncompleteall as specified and direcred by Engr-in-Charge. |
| 4 | Supply only in replacement of street light driver of 55 watt to 100 watt, 230V,50Hz suitable foroperation over voltage range of 140V to 270V by emoving from existing positioncompleteall as specified and direcred by Engr-in-Charge. |
| 5 | M & L in for DK Thermoplastic cable junction boxes IP 65 with of size 185x165x60 of metric knockouts for cable entry, weather proof for outdoor installationand including glands and with 4 terminals for terminating oneincoming and outgoingUG cable of size 10/16 sqmm 2/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and boltsandincl provn for fixing 01 No. of single pole MCBs 6-32 amps,10KA and MCB TP 6-32 amps, 10 KA, ‘C’ series 01 Noinside the box incl taking down old u/s junction box complete all as specified and directed. Make : Sintex/Hensal or equivalentapproved by GE. |
| 6 | S&F Busbar Chambers4 way 100 Amps outdoor type (IP 65/66) pole mounted including provision of fixing on poleby means of suitable size of clamps with nut and bolts including necessary connection including taking down of old u/s bus bar completed all as specified and as directed. Make Havells cat part No IHBC010004 or equivalent make of SMC/Hensel |
| 7 | S&F in repairs LED street light fittings, IP-66, 72 watt including bracket made out of 40 mm dia light grade GI pipe not less than 1.2 mtr long bend to shape duly fixed with MS clamps of 3mm thick, nut, bolts etc complete fixed to steel tabular poles including electrical connection complete with 3 core 1.5 Sqmm PVC sheathed stranded copper wire ISI marked from junction box to fitting all as specified and as directed, Make PHILIPS, cat part No \"BRP410LED CW 072 MR FG S1 PSU GR\" or equivalent model of Crompton/Bajaj. |
| 8 | Supply and Laying in replacement u/s cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables of Size of 16 Sqmm 4 core (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in Trench with the help of shadel of following size as required at site, Make : MESCAB/HAVELLS/POLYCAB/GLOSTER/KEI |
| 9 | Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n\"exc. 1.50m deep forfoundationand getting out including forming bottom surface to required level or slope, complete all as specified and directed by Engineer-in- Charge. |
| 10 | Returning filling including spreading leveling watering and well ramming in layers not exc 25Cmin soft/ loose soil, complete all as specified and directed. |
| 11 | Removing excavated material in soft/ loose soil n\"exc 50M and depositing where directed at a level n\"exc1.5M above the starting point, complete all as specified and directed. |
| 12 | M&L for sand cushioning to U/G cable in layers in trenches complete all as specified and directed.Note :-Only Puned layers shall be measured for payment |
| 13 | M&L for well burnt bricks, sub class \"B\" bricks of size 250mmx125mmx75mm, best quality locally available laid flat dry in trenches for cable protection complete all as specified and as directed. |
| 14 | M&L for painting of steel tubular pole of any size , vertical complete with cross arms with one coat of aluminium paint after cleaning and preparation of surfaces of poles, cross arms, painting 30 cm wide Yellow and black strip on poles up to 1.5 mtr high above coping level andnumbering of size 70mmx40mm by using stencil to the pole with black synthetic enemal paint (1st grade ) complete all as directed. |
| 15 | S&F in repair GI Pipes 40mm bore lightgrade in any positionfor protection of cablefixed at pole/laid under road , nallah, crossingwalls under floors etc completeall as specified and directed.Make : TATA/BANSAL/JINDAL or equivalent |
| 16 | M&L for servicing of Diesel Engine driven generating sets 415 Volts AC 3 phase 4 wire of capacity 82.5 KVA DG set for overhauling tuning up and greasing to all movable parts, repair/replacement of old unserviceable accessories/parts with new accessories/parts including draining of complete engine oil and washing the internal engine with kerosene oil and refilling new engine oil of required qty all as specified and as directed. Note:- Quoted rate shall be deemed to include for lub oil filter, water filter, diesel filter and coolent filter of required qty as per existing DG set. |
| 17 | All as per item No 16 above but capacity 62.5 kVA DG set all as specified and as directed by Engr-in-Charge. |
| 18 | All as per item No 16 above but capacity 45 kVA DG set all as specified and as directed by Engr-in-Charge. |
| 19 | All as per item No 16 above but capacity 12.5 kVA DG set all as specified and as directed by Engr-in-Charge. |
| 20 | Supply and fixing in replacement V-belt as per existing shape and size including taking out old unserviceable item suitable for 82.5 kVA DG set as per same shape and size all as specified and as directed. |
| 21 | All as per item No 20 but capacity of 62.5 kVA DG set all as specified and as directed. |
| 22 | All as per item No 20 but capacity of 45 kVA DG set all as specified and as directed. |
| 23 | All as per item No 20 but capacity of 12.5 kVA DG set all as specified and as directed. |
| 24 | M&L for cleaning of the fuel tank of DG sets of 82.5 kVA capacity after decaning the diesel,after through cleaningwith kerosene oilincluding replacement oflevel indicator pipe complete all as directed by Engr-incharge. |
| 25 | All as per item No 24 but capacity of 62.5 kVA DG set all as specified and as directed. |
| 26 | All as per item No 24 but capacity of 45 kVA DG set all as specified and as directed. |
| 27 | Supply & top up water coolant in radiotor of DG set of any capacity any make,Make : Bosch/TVS Girling/Volvo line or of equivalent make all as directed by Engr-incharge. |
| 28 | Supply & fixing in replacement of air filter suitable for 82.5 kVA DG set all as specified and as directed. |
| 29 | All as per item No 28 but capacity of 62.5 kVA DG set all as specified and as directed. |
| 30 | Supply & fixing in replacement of lub oil filter suitable for 82.5 & 45 kVA DG set all as specified and as directed. |
| 31 | Supply & fixing in replacement of fuel filter suitable for 82.5 & 45 kVA DG set all as specified and as directed. |
| 32 | Supply & Fix in repair MCCB 200 Amps 4 pole, 3 phase, 415 volt all as specified and directed by Engr-in-charge. Make: Legrand/Havells/L&T/Schneider/ABB or eqvt as approved by GE. |
| 33 | Supply & Fix in repair MCCB 160 Amps 4 pole, 3 phase, 415 volt all as specified and directed by Engr-in-charge. Make: Legrand/Havells/L&T/Schneider/ABB or eqvt as approved by GE. |
| 34 | Supply & Fix in repair MCCB 100 Amps 4 pole, 3 phase, 415 volt all as specified and directed by Engr-in-charge. Make: Legrand/Havells/L&T/Schneider/ABB or eqvt as approved by GE. |
| 35 | Supply & Fix in repair MCCB 63 Amps 4 pole, 3 phase, 415 volt all as specified and directed by Engr-in-charge. Make: Legrand/Havells/L&T/Schneider/ABB or eqvt as approved by GE. |
| 36 | Taking out governor speed control system, cleaning, servicing and overhauling the system complete, refitting and setting/adjusting the governor speed including testing complete suitable for 45kVA DG set all as specified and as directed. |
| 37 | M&L for servicing the starting pannel of DG set, cleaning and adjusting the time setting, cleaning and tightening the loose connection of contacor, timer, HRC fuse, ammeter, volt meter etc and making for smooth functioning of the starting operation of 82.5 kVA cap complete all as specified and as directed. |
| 38 | Supply only new Engine oil 15W40 / 30W50 Make : HP/BP/Indian/Servo/Castrol |
| 39 | M&L for XLPE insulated, amoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 3.5 core of Make: Havells/Polycab/KEI or eqvt as approved by GE. |
| 40 | M&L for XLPE insulated, amoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm 3.5 core of Make: Havells/Polycab/KEI or eqvt as approved by GE. |
| 41 | M&L for XLPE insulated, amoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 3.5 core of Make: Havells/Polycab/KEI or eqvt as approved by GE. |
| 42 | Supply and laying of brick sub class \"B\" for protection of cable all as specified and as directed by Engr-in-Charge. |
| 43 | M&L for providing dry river sand as in sand cushioning to under ground cable including punning down of sand in layers as specified and as directed.Note : Only compacted thickness will be measured and paid. |
| 44 | M&L for earthing coplete with galvanised steel earth plate electrode 60 cm x 60cm x 3.15 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised iron strip of 25x4 mm connected to test point by means of nut, bolts and washers madeout of galvanised iron or steel all including earthing pit in PCC (1:3:6) type C1, RCC (1:2:4) typer B1 precast cover slap with one handle made out of8 mm dia round bar, 20 mm dia (medium grade) protecation pipe and providing layer of charcoal or cike and salt in alternative layers necessary earth work complete as shown in electrical plate No 3all as specified including testing on completion incl dismantling of old U/S earthing all as directed. |
| 45 | Supply & Fix in repair change over switch 125 Amps 4 pole, 3 phase, 415 volt all as specified and directed by Engr-in-charge.Make:Legrand/Havells/L&T/Schneider/ABB or eqvt as approved by GE. |
| 46 | Supply & Fix in repair change over switch 160 Amps 4 pole, 3 phase, 415 volt all as specified and directed by Engr-in-charge. Make:Legrand/Havells/L&T/Schneider/ABB or eqvt as approved by GE. |
| 47 | Supply and fixing in replacement of magneic pick up for 45/62.5/82.5 KVA set as per existing all as specified and as directed. |
| 48 | Supply and fixing in replacement of self starter for 82.5 kVA set as per existing all as specified and as directed. |
| 49 | Supply and fixing in replacement of ECD card for 45 kVA set as per existing all as specified and as directed. |
| 50 | M & L for cleaning and servicing of radiator suitable for 12.5 kVA DG set by soda water solution after taking out its position, cleaning of fins and finally washing with fresh water, refixing in its original position complete all as specified and as directed. |
| 51 | Supply & Laying in replacement of GI pipe dia 40mmmedium grade as protectionfor UG cable/for stand of post top lantern complete all as specified & directed of Make: Tata/Jindal/Bansal or eqvt as approved by GE. |
| 52 | Taking out of old unserviceable Air termination rod of any type and size all as specified and directed. |
| 53 | Supply and fix in replacement of air terminatiion, single pointed copper rod 12mm dia 300mm long all as specified and directed by Engr -in- Charge. |
| 54 | Taking down old unserviceable GI/Copper/Aluminium strip of any type and any size. |
| 55 | M&L in replacement of aluminium strip 25 x 3.15mm with saddles and fixing screws/mounted on porcelain insulator/laid in trenches for roof conductors and down conductors above ground all as specified and directed by Engr -in-Charge. |
| 56 | Supply and fix in replacement of GI strip 32x6 mm complete and buried in ground all as specified and as directed by Engr-in-Charge. |
| 57 | Taking out of old unserviceable test point terminal box of of any type and size all as specified and directed. |
| 58 | M&L in replacement of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed by Engr -in-Charge. |
| 59 | Taking out of old unserviceable GI tubing of 40 mm bore light grade earth protection pipe in trenches etc. |
| 60 | M&L in replacementof GI tubing light grade 40 mm bore complete with all fittings like flange/clamp/nuts/GI wire & bolts etc on roof top of required length for fixing lightening conductors all as required and directed. |
| 61 | M&L in replacement of porcelain/epoxy white/brown/green spacer insulator with one GI stud bolts with nut and washers with necessary drilling for bolts hole for holding/fixing roof conductor/ down conductor of lightening conductor complete all as specified and as directed by Engr-in-Charge. |
| 62 | M&L for taking out old earthing materials like salt/charcoal which earth value not good and supply and fill new salt/charcoal for obtaining desire earth value complete all as specified and as directed. |
| 63 | Supply and fix in replacement of GI strip 25x4mm complete and buried in ground all as specified and as directed by Engr-in-Charge. |
| 64 | M&L for repair and refixing of damaged/tilted air termination rod of any size with nut bolts/PCC as per existing connected to GI/Al strip properly all as directed at site. |
| 65 | M&L for repair and refixing straightening and dressing of GI/Al strip with saddles/insulator/connector with screw and making good of disturbed strip all as directed at site. |
| 66 | M&L for checking the existing earth pit value with the help of insulation tester, necessary wire and rod etc and measuring the values in front of MES JE and concerned unit rep and maintaining the earth value register and deposit to MES all as specified and directed. |
| 67 | M&L for making new earthing pits with pit cover in PCC (1:3:6) type C2 with necessary painting in repair as existing complete all as specified and as directed at site. |
| 68 | Dismantling of servo controlled voltage stabilizer by disconnecting all internal electric connection and disconnecting of LT connection earthing lead and taking down carefully defective servo controlled voltage stabilizer of capacity 75 kVA, 415 volts from sub station and after necessary repair and installing the same servo controlled voltage stbilizer to its original position including reconnection of all electrical cables wires and earthing connection complete all as specified and as directed by Engr-in-Charge. |
| 69 | S&F in replacement of top cover gasket sheet as per existing size and complete for servo controlled voltage stabilizer of capacity 75 kVA complete all as specified and as directed by Engr-in-Charge. |
| 70 | Reassembling of servo controlled voltage stabilizer including heating, varnishing, testing and commissioning complete all as specified and as directed by Engr-in-Charge. |
| 71 | S&F in repair controller circuit board suitable for 75 kVA servo controlled voltage stabilizer complete all as specified and as directed by Engr-in-Charge. |
| 72 | S&F in repair synchronising motor suitable for 75 kVA servo controlled voltage stabilizer complete all as specified and as directed by Engr-in-Charge. |
| 73 | S&F in repair contactor suitable size for 75 kVA servo controlled voltage stabilizer complete all as specified and as directed by Engr-in-Charge. |
| 74 | Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment. |
| 75 | SCHEDULE OF CREDIT |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender