Tender For Repair And Maintenance Of Internal Wiring/Summer Appliances Alongwith Connected Items At Abhor Under Ge (Af) Bhisiana, bhisiana-Punjab

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Internal Wiring/Summer Appliances Alongwith Connected Items At Abhor Under Ge (Af) Bhisiana. Submission Date for this Tender is 12-01-2023. Air Conditioner Tenders in bhisiana Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

35222206
Corrigendum : Tender For Repair And Maintenance Of Internal Wiring/Summer Appliances Alongwith Connected Items At Abhor Under Ge (Af) Bhisiana
Open Tender
Indian
Punjab
bhisiana
12-01-2023

Tender Details

Tender For Repair And Maintenance Of Internal Wiring / Summer Appliances Alongwith Connected Items At Abhor Under Ge ( Af ) Bhisiana

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 18800.0 /-
Tender Value
Refer document

BOQ Items

NAME OFWORK : REPAIR & MAINT OF INTERNAL WIRING AND SUMMER APPLIANCES ALONGWITH CONNECTED ITEMSATABHOR UNDER GE(AF) BHISIANA
Sl. No. Item Description
1INTERNAL ELECTRIFICATION
2S&F in repair of unserviceable and M&L for Submain wiring with two single core of 4.00 Sqmm and one single core of 4.00 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in PVC Conduit (ISI Marked) of size 20/25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface.
3S&F in repair ofunserviceable and M&L for Submain wiring with two single core of 6.00 Sqmm and one single core of 6.0 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in PVC Conduit (ISI Marked) of size 20/25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface.
4M&L for Concealed Point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathedcable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 19/20/25mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm PVC insulatedunsheathedcable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for One lightpoint, ceiling fan/Exhaust fanpoint controlled by one switch 6 Amp one way Complete all as specified and as directed by Engineer in Charge.
5All as Item No 4 above butbell point controlled by one switch 6 Amp one way.
6All as item no 4 above but one 3 Pin Socket5/6 Amp on the same board.
7All as item no4 above but one 3 pin Socket5/6 Amp on the independent board.
8All as per item No 4 here in before but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 Amp multi purpose socket combination point on independent board.
9S&F in repairs switch piano flush type single pole 1 way 6 A,complete all as specified and directed.
10S&F in repairs switch piano flush type single pole 1 way 16 A,complete all as specified and directed.
11S&F in repairs bell push flush type single pole 1 way 5/6 A,complete all as specified and directed.
12S&F in repairs Bell , AC, 230 volts, ding dong complete all as specified and directed.
13S&F in repairs socket outlet 2 in 1, 3 Pin5 Amps, flush type complete all as specified and directed.
14S&F in repairs socket outlet 3 pin,15 Amps flush type complete all as specified and directed.
15S&F in repairs stepped type electronic fan regulator flush type complete all as specified and directed.
16S&F in repairs modular white cover plate with frame 1 module complete all as directed by Engineer in Charge.
17S&F in repairs modular white cover plate with frame 3 module complete all as directed by Engineer in Charge.
18S&F in repairs modular white cover plate with frame 6/8 module complete all as directed by Engineer in Charge.
19S&F in repairs modular Switch 1 way 6 Amp, 1 module , complete all as specified and as directed.
20S&F in repairs inModular Bell Push Button 6 Amp, 1 module suitable for Call Bell and , complete all as specified and as directed.
21S&F in repairs in modular Socket Outlet 6 Amp 2/3 pin combined 2 module, complete all as specified and as directed.
22S&F in repairs modular Switch 1 way 16 Amp, 1 module , complete all as specified and as directed.
23S&F in repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type univeralal, complete all as specified and as directed.
24Ditto- but 3 pin 5A, complete all as specified and as directed.
25S&F in repairelectronic dimmers, 450W, 250V flush type on the exiting phenoli laminated sheet etc. as requred complete all as specified and as directed.
26S&F in repairs ceiling rose Polycarbonate, Isolated body surface type bakelite 65x50 mm three terminal complete all as specified and directed.
27SS&F in repairLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V ACdecorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer in Charge.
28S&F in repair of LED lights fitting 1x 22 W, 220V, AC decorative box type with driver, holder includingLED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceilingrose complete all as specified and directed by Engineer in Charge.
29S&F in repair of new generation energy saving 9/10 watt LED bulk head (porch light fitting) made of plasitic housing with opal diffuser complete all as specified and directed by Engr-in-Charge.
30Supply and fix in repairs 36/40 watt recessed mounted LED luminaire suitable for armstrong/grid ceiling with super bright LED fittings with connector block etc with short circuit protection , open protection , reverse polarity protection , high voltage protection complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
31Supply and fixing LED street light fitting 35 Wat230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete all as specified and directed by Engr-in-Charge.
32S&F in repairs 12 wattLED Bulb with base captype complete all as specified and directed by Engr in Charge.
33Taking down U/s Ceiling fan from existing point on differenct building"sroom at various floors of Abohar stn 44 WEUceiling /exhaust/wall mounted fans of any size and any make/model,moving toworkshop as approved by GE/Engineer-in-charge , dismantaling the same , cutting and removing the old defective/burnt out winding, cleaning the core of the fan motor, re-winding the fan motor by using machine with supper enemelled copper winding wire and using insulating materials, varnishing the assembly and re-assembling the fan including removing of U/S bush and bearing and supply & Fix new bush and bearing testing etc. complete afrer repairing and testing of fanthe same will be again install in same locatiion/building in abohar and same all as specified and directed by Engineer-in-charge. MAKE of winding wire : Devi Dayal/Chetak/HTP Thulax. NOTE: All Defective / Unserviceable parts/items other than winding wire,varnish and insulating material, shall be measured separately and paid for under respective item of this schedule.
34All as above item no 33 here-in-beforebut for exhaust fans of 230/300 mm sweep any type complete all as specified and directed by Engineer in charge.
35All as abive item no 33here-in-beforebut for exhaust fans of 400/450 mm sweep any type complete all as specified and directed by Engineer in charge.
36S&F in repair for replacement of fan blade of ceiling fan Complete all as directed by Engr-in-charge
37S&F in repair for replacement of fan blade of Exhaust fan Complete all asdirected by Engr-in-charge
38Taking Down U/S Geyser form existing location and deposit to MES store yard & Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto2 KW capacity 25 litre, BEE 5 Starrated complete with all accessoriessuch as safety valve, thermostate thermostate, NRV, connection piece etc Complete all as specified and directed by Engineer in Charge.
39Supply & fix in repair of Geyser metalic rusted bodyform existing location ofelectric water heater, storage type steel body with copper inner tank and heating element upto2 KW capacity 25 litre, safety valve, thermostate thermostate,NRV, connection Completeall as specifiedand as directed by Engineer in Charge.
40Taking down existing aluminum/copperPoint wiring including wooden batten or taking out from existing complete (light/fan/socket) including all fittings such as ceiling rose, switches, regulators,sockets etc and making good distrubed surface of wall,floor & ceiling etc complete all as specified and directed.
41S & F in repair Capacitor 2.5 mfd complete all as specified and directed by Engineer-incharge.
42S & F in repair Capacitor 3.5 mfd complete all as specified and directed by Engineer-incharge.
43S & F in repair Capacitor 4mfd complete all as specified and directed by Engineer-incharge.
44S&F in repairs Tripple pole and neutral (TPN) 4 way MCB distribution box double door powder coated sheet metal encloser415 volts TPN including 200 Amps rated bus bar complete all as specified and directed.
45S&F in repairs Single pole and neutral (SPN) 8 way MCB distribution box double door powder coated sheet metal encloser240 voltsincluding 200 Amps rated bus bar complete all as specified and directed.
46S&F in repairs 415V 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning TPN 40 To 100 AMP complete all as specified and directed.
47S&F in repairs of MCB single pole (SP) B curve240 Volt 6 to 32 Amp, rupturing capacity 10 KA complete all as specified and directed.
48S&F in repairs of MCB single pole & Neutral (SPN)B curve 240 Volt 40 Amp, rupturing capacity 10 KA complete all as specified and directed.
49S&F in repairs of MCCB 125 Amp 4 pole50 Hz 415 volt thermal magnetic release type with breaking capacity 16 KA complete all as specified and directed by Engr in Charge.
50Sypply and fix in repairs of MCCB 63 to 100 Amp 3 pole50 Hz 415 volt thermal magnetic release type with breaking capacity 16 KA complete all as specified and directed by Engr in Charge.
51Taking down carefully water heater (Geyser) any capacity any make after removing electric & water connections from existing system for carrying out repairs(Repairs will be measured and paid separately under appropriate items) and refixing the same after carrying out necessary repairs to original place all as directed by Engineer-in-Charge.
52Removing existing hot & cold water copper/PVC flexible pipe connection from geyser and S&F new brass chromium plated water pipe with brass nut and washers of good quality about 45cm long in hot & cold water connections and connecting complete all as specified and directed by Engr in Charge.
53Removing existing hot & cold water copper/PVC flexible pipe connection from geyser and S&F new brass chromium plated water pipe with brass nut and washers of good quality about 45cm long in hot & cold water connections and connecting complete all as specified and directed by Engr in Charge.
54S & F in repair of heating element 1.5 kW for 25/35 ltrs capacity geyser ISI marked (as approved) complete all as specified and directed by Engr in Charge.
55S & F in repair of thermostatic switch of geyser complete all as specified and directed by Engr in Charge.
56S & F in repair Stop valves, cast copper alloy, screwed down, high pressure, with crutch screwed both ends for iron pipe or for unions of dia 15mm complete all as specified and directed by Engr in Charge.
57S&F in repair forEarthing complete with galvanised steel plate electrode, 600 x 600 x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to earthing lead of 4 mm dia galvanised iron or steel wire all as shown in para No. 4 to the earthing test point all as specified and as directed.Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing complete all as specified and directed by Engr in Charge.
58S&F in repair forEarthing complete with copper plate electrode,60×60cm ×3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to 20×3mm copper strip as earthing test point all as specified and as directed.Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing complete all as specified and directed by Engr in Charge.
59S&F in replacement of Earth continuity copper conductor or main earthing lead fixed to wall on battenor recess or chases or buried inground or drawn in conduit/pipe orfixed to poles or any other indicated size of copper strip20x3mm copper strip complete all as specified and directed by Engr in Charge.
60S&F in replacement of changeover switch 63 amp with sitable size 45X45 cm sqaure shapeof steel enclosure floor mounted legs made 06 mm thick iron flate plate and heightof legs 60 cmm long, complete all as specified and directed by Engineer in Charge . Note: The Quoted unit rateincluded PCC work 1:3:6 for fixing of change over switch all as specifed and as directed
61Detecting the leakage from geyser of any size/ any model and arresting the same by brazing/ soldering (as approved) complete all as specified and directed by Engr in Charge.
62SUMMER APPLIANCES
63Taking down unserviceable PVC drain pipe & supply and fix with newPVC drain pipe with clamps set of size 20 mm dia up to 2 mtrs, complete all as specified and as directed.
64Taking out unserviceableandSupply and fix copper capillary tube suitable for window /split type AC"s water coolers/Refrigerator, complete all as specified and as directed.
65Dismantling /taking down & M&L for servicing and repairs of Window /split ac 1.5/ 2 ton capacity for m, servicing complete , cleaning of evaporator coil, condenser , blower, base tray, drain hole, replacemtn of polypropelene pad, oiling of fan motor , checking of wiring connections, terminals capacitor , relay selector switches , drainage , rubber bushes bearing bushes ec and refixing athe same in position , and testing complete in full loadall as directed Note :Split Acs are installed at various floors in AF Station Bhisiana ie. Ground floor to 3rd floor . Contractor shall arrange his own arrangemnt to access the repairs for splitunits . No tools and plants shall be supplied to the contractor from the department
66S&F running capacitor40/45/50/55/60 36/45 mfdsuitable for 1.5/.2 Ton capacity of window type AC fixed in replacementcomplete all as specified and as directed by Engineer-in-charge.BAJAJ/HAVELLS/SHARDA /ASIAN
67S&F capacitor6 mfdsuitable for blower motor,fixed in replacementcomplete all as specified and as directed by Engineer-in-charge.
68S&F in repair ofRemote suitable for split/window AC any make/type all as specified and directed by Engr-in-charge
69S&F in replacement fan blade for window/split ACof 1.5/2.0 TR all as specified and directed by Engr-in-charge.
70Supply & Fix in repair ofpvc insulated 1100v grade of size 2.5 sqmm, 3 core pvc round sheathed insulated flexible flate submersibleFR copper cable, Complete all as specified and directed by Engr-in-Charge.
71Supply & Fix in repair of single pole and neutral enclosure with, two pin and earth plug and socket 240 volts complete with one MCB 20/25 Amps including taking down existing all as specified and directed by Engineer-in-Charge.
72Supply & Fix in repair of Blower motor single phase 230 volts, 50 Hz, 1/5 HP, 900 RPM suitable for window type AC of capacity 1.5/ 2.0 TR fixed in replacement complete all as specified and directed by Engineer in Charge.
73S&F Evaporator coil assembly complete suitable for window type /Spit ype AC of capacity 1.5/ 2.0 TR etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directedby Engineer-in-charge.
74S&F Condensing coil (Copper coil) assembly complete suitable for window type/Split TypeAC of capacity 1.5/2 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed.
75M&L for Cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-22/R-134a/R-410/R-32/R-407 with anti moisture substance and replacement of filter along with rectification of leakage system in the window type AC /Spiit type ac of capacity 1.5/ 2.0 Ton including installation at site and testing on full load complete all as specified and as directed by Engineer-in-charge.
76M&L for rewinding of blower motor of window type /Split type AC 1.5 Ton capacity single phase 1/5 HP, 900 RPM with super enameled copper wire of existing gauge including replacement of bush and nut and bolts, washer etc complete all as specified and as directed by Engineer-in-charge.
77Taking down /dismantling of old unserviceabledefective sealed compressor of cap 2/1.50 TR of Split type AC /window and replacement in with manufactures reconditioned compressorcompany makereceprocatingcompressorof cap 2/1.50 TR bysoldering /brazing of copper Tubes and replacement offoundation pads including nut& bolt and washers as required and charging with Refrigerant R-22/R-134a/R-410 to its rated capacityand testing of leakage in the system if any andmaking good, Testing on full load after reinstalling the same.
78Taking down /dismantling of old unserviceabledefective Rotary compressor of cap 2/1.5 TR of Split type/WindowAC and replacement in new rotarycompressor of cap 2/1.5 TR bysoldering /brazing of copper Tubes and replacement offoundation pads including nut& bolt and washers as required and charging with Refrigerant R-22/R-134a/R-410 to its rated capacityand testing of leakage in the system if any andmaking good, Testing on full load after reinstalling the same.
79Supply & Fix in repair of Insulation to refrigerant pipes of split ACs any make & type complete with suitable size for suction and discharge refrigerant pipes including necessary clamps etc.
80Taking down U/s & S&F thermostat suitable for split/window AC/refrigerator any capacity all as specified and directed by engr-in-charge
81S&F in replacement Oscilation motor with swing blade strip for indoor unit of split AC 1.5/2.0 TR capacity same specification /make as per existing one complete all as specified and directed.
82M &L fordismantling/taking down of existing Split type AC/Window Typa ac of cap 2.0/1.5 TR complete with Indoor/Outdoor unit from existing location with all Electric Connection and all refrigerant Pipes and matching the existing disturbed surface area, Including Refixing/Re-Installation of Split type AC Shifted to new location on suitable wall places complete all as specified and directed by Engr in Charge. (Refrigerant Recharging gas, Insulation of Copper tubes, copper tubes paid & measured seprate under respective item)
83Supply in replacement of Copper Pipe Line of size 1/4" to 1/2" for Split/Window type AC of any capacity complete all as specified and directed by engr in charge.
84Supply in replacement of Copper Pipe Line of size 3/8"" to 5/8" for Split/Window type AC of any capacity complete all as specified and directed by engr in charge.
85Taking down unserviceable brass suction valve & supply & fix new suction valve 1/2" suitable for cassette /split type
86Taking down unserviceable brass discharge valve & supply & fix new brass dischargevalve 3/8" suitable for cassette /split type
87Supply only in replacement of Brass flair nuts 1/2"" to1/4"" for Split/Window type AC of any capacity complete all as specified and directed.
88S&F Fan motorfor Outdoor unit, of same specification as per existing one suitable for Split type AC of capacity 1.5 Ton fixed in replacement complete all as specified and directed
89S&F Blower motorfor Indoor unit,same specification as per existing one suitable for Split type AC of capacity 1.5/2.0 Ton fixed in replacement complete all as specified and directed
90M&L for fixing of duel capacitor suitable for both window/split AC all as specified and directed by engr-in-charge
91Taking down U/S & Supply and install invertor based split AC with cordless remote of capacity 1.5 TON ( Copper coil Both Indoor & Out door Unit) electric driven single phase , 230 volts, New 5 star rating including all accessories like brackets, rubber tubing , copper tubingas required at site , gas charging , with auto filter clean technilogy etc including testing and commissionin with as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as directed Make Hitachi/LG/Blue star/Godrej/"O" General/Voltas Note :- All cooling /condensing coil should be copper material
92Taking down U/S &Supply and install Voltage stablizer coppper winding automatic digital typeoperation single phase naturally air cooled indoor type & designed for input variation between 150 Volt to 285 Volt with output voltage stablized at 230 Volt with accuracy of (+/-)2.5 percent of capacity 4KVA .Make:V guard ,Steady Volt,Microtek
93Supply and fix in replacement complete PCB with Remote control for Outdoor unit of Split type AC cap. 1.5/ 2.0 TR, microprocessor based with transmission and receiving unit, cordless with features ofmode slection, timer, temperature control or as per existing specification and model complete all as specified and directed.
94Attending day to day complaintof detecting the faultin Refrigerator/Water cooler/ Window AC/Split /desertCooler /Voltage stabilizer/ Electric supply in all eqpt like loose nut and bolts,leakage of tube,checking electrical connections,charging of refrigerant, fan motor,compressor fault etc all as specified and directed.Note:- Any defective part which are required to be replaced to make functional ACs shall me measured and paid seperately. The contractor should attend the complaint and rectify the defect within 02 days (Maximum) failing which RS @500 per day per AC (split / window 1.5 / 2TR ) /water cooler / Refrigerator will be recovered from the RAR/Final bill.
95S&F in replacementBlower drumassembly complete for Split AC of 1.5/2.0 ton as per existing all as specified and as directed.
96S&F in replacement LCD Digital type AC timer for cyclic operation of 02 any type of Air Conditioner with displaying AC 1/AC 2 on indication & 1 to 24 hours programmable to take load upto 2 Ton window/split AC with auto/manual facility at site all as specified & directed.
97M & L for complete maintenance and repairs of refrigerator of capacity 165 to 310 ltrs including servicing cleaning of refrigerator internal portion checking of compressor, condenser and replacement of overload relay, thermostat, capacitor, wiring,veg tray,chiller tray,strainer,freezer door and timer etc and testing complete all as directed. Notes of Item No. 1 to 4 (i)Rates includes servicing of unit for one time and will be considered as one job. (ii)Rates are including for Spares required for replacement which is mentioned in servicing item no. (1 to 4) do not paid separately. (iii)Servicing shall be carried out in the presence of Engr-in-Charge or his representative.Necessary service report(complaint slip) is to be signed by the rep. of AGE E/M. (iv)Old spare parts retrived after replacement will be the property of the cotractor under schedule of credit and shall be removed by the contractor outside at his own cost.
98Dismantling of defective compressor sealed unit of refrigerator from existing refrigerator by removing suction/ discharge line and providing new approved factory sealedcompressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134/R22/407A including connection suction/ discharge line complete.165 to 310Ltrs capacity refrigerator
99Supply and fix Thermostat switch with defrosting system suitable for refrigerator of capacity 165 to310 Ltrsfixed in repairs complete all as specified and as directed by Engineer-in-charge.
100Supply and fix Starting relay assembly suitable for refrigerator ofcapacity 165 to 310 Ltr fixed in repairs complete all as specified and as directed by Engineer-in-charge.
101Taking down unserviceable Water cooler tray 80/40,80/120 ltr and supply and fix new water waste tray stainless steel material including nut bilt, wahser , gaswelding work etcin existing water coolerall as specified and directed.
102Dismantling of defective compressor sealed unit of water cooler from existing foundation by removing suction/ discharge line and providing new approved compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134 R22 or as existing including connection suction/ discharge line complete all as specified and as directed by Engr-in-charge.
103Taking down of unserviceable condensor coil and providing new condensor coil of same size and quality forwater cooler capacity upto 150 LPH.all as specified and as directed by Engr-in-charge
104Taking out unserviceableand Supply and fix fan motor capacitor suitable for water cooler of 40/80/60/120/150 ltr cap of water coolerall as specified and as directed by Engr-in-charge
105Taking out defective capacitor and supply and fix running capacitir suitable forof 40/80/60/120/150 ltr cap of water cooler Make : Shriram/Ranutrol all as specified and as directed by Engr-in-charge
106Taking down unserviceable starting relay and supply and fix starting relay for water cooler cap 40/80/60/120/150 ltrs all as specified and as directed by Engr-in-charge
107Taking down unserviceable fan motor blade & supply and fix fan motor blade for water cooler cap 40/80/60/120/150 ltrs all as specified and as directed by Engr-in-charge
108Taking down unserviceable push cock & supply and fix new push cock of brass chromium plated suitable for water coolerall as specified and as directed by Engr-in-charge
109Supply and install Voltage stablizer copper winding automaticdigital type operation single phase naturally air cooled indoor type & designed for input variation between 150 Volt to 285 Volt with output voltage stablized at 230 Volt with accuracy of (+/-)2.5 percent of capacity 5KVA .Make: V guard /Steady Volt/ Microtek
110DESERT COOLER
111Taking down carefully desert coolers from various buildings and floors (viz. ground floor, first floor, second floor and third floor) at AF Station Abhorfor repair and refixing after completion of necessaryrepairs. Note : Contractor shall make his own arrangements to access various floors and to provide tools and plants for taking down and refixing of desert cooler.The rate quoted shall be deemed to include all these arrangements all as required at site .
112Dismantling of unserviceable wood wool pad and providing not less than 2.5 kg adequate dense newwood wool pad 03 Nos supported with suitable size GI wire & bamboo/wood stick for supporting of wool pad inside complete includingfitted with bolts and nuts suitable for existingdesert cooler as per sample
113M&L for Preparation of old painted surface and applying DUCCO paint by spray gun fully matched with its existing colour outside and two coat of black bituminous paint inside the water cooler base/compressor compartment including removal of all dust and all foreign material with the help of sand paper and rubbing with cleaning compound and polishing on painted surface etc complete all as specified and as directed by Engineer-in-charge.
114Taking out of unserviceable transparent flexible PVC pipe of 15 mm dia and providing new PVCtransparentflexible pipe of 15 dia , 03 branch minimum length 0.8 mtr long including clamp and of same quality for water circulation pump to air cooler all as specified and as directed.
115Ditto- all as per item No. 114 herein before but flexible PVC pipe of size 20 mm dia.
116Dismantling of unserviceable submersible water circulation pump assembly and providing of new submersible electric driven single phase 230 volts, 50 hz 20 watt water circulation pump, nut bolts, clamp, of head minimum1.6 Mtrfor desert cooler. Make:- ZOLTO/ Amickart,star universal.
117Taking down old and unserviceable steel tube /PVC /CPVC tube of 15mm dia and laying only new GI tube, 15 mm dia, medium grade, galvanised, with all fittings such as tees, bends, elbows, reducers, union etc. and fixing accessories such as lock nuts, saddles, pipe hook, etc complete fixed to walls and ceilings or laid in floors for desert cooler connection.
118M&L for rewinding of exhaust fan motor of desert cooler of size / capacity 4500 CFM Exhaust 1/6 HP1250 rpm including replacement of nut bolts, clamps . Note The cost shal be included taking down and re-fixing in existing location including clamp nut bolts etc.
119Dismantling of unserviceable fan bladeand providing of new fan blade made out of aluminium casting suitable for existing desert cooler.make and model complete all as specified and directed by Engineer in charge.
120Disconnecting of unserviceable selector switchdesert cooler and providing of new selector switch suitable for existing desert cooler complete all as specified and directed by Engineer in charge.
121Taking down unserviceable capacitor 4 MFD and S & F new capacitor 4 MFD, 220 Volts all as specified and as directed.Make : Crompton/Havells/C&S / EPCOS.
122S&F in replacement of control piano switch, flush type, 5 Amps suitable for existing desert cooler including taking down the old unserviceable switch all as specified and as directed.
123S&F in replacement of plug top, 3 pin, 5 Amps including taking down the old unserviceable plug top, all as specified and as directed.Make : Anchor, Leader, Crabtree.
124S&F in replacement offlexible FRPVC round sheathed insulated flexible copper cable of size 1.5 Sq mm, 3 core, including taking down old unserviceable cable all as specified and as directed.
125S&F in replacement ofwater tray of size 85 cm x 70 cm and height 20 cm, made of GI sheet 0.63 mm thick suitable for desert cooler including taking out old unserviceable tray.
126S&F in replacement ofwater tray of size 95 cm x 75 cm and height 20 cm, made of GI sheet 0.63 mm thick suitable for desert cooler including taking out old unserviceable tray.
127Material and labour for providing new plywood of 6mm thickness,grade BWR,type BB,fixed with screwes to timber frame work in roomwindows suitable for desert cooler with grill face opening complete all as specified and directed.
128Taking down U/s rusted body of desert cooler and M&L new desert cooler bodymade out of 01 mm thick galvanised steel sheet with wood wool fitted in frame made from 25x25x3 mm angle iron and 25x25 mm size MS wire mesh net of 14swg dia fitted on both sides for supporting woodwool including suitable size top and bottom water tray made of 1.00 mm GIsheet and all fixingaccessories for fabrication of complete newouter shell bodycover made out og GI sheet(body size 100cmx90 cm) for desert cooler of size / capacity 5000 Cum Exhaust fan typeand including preperation of surface and applying with two coats of synthetic enamel pait over one coat of primer by spray painting Complete all as specified and as directed by Engineer in Charge.
129Taking down U/s desert cooler and supply, installation , testing , commissioning of desert cooler of capacity 4500 Cum per hour made out of 01 mm thick galvanised steel sheet with complete fully exhaust fan 450 mm sweep , 1400 rpm motorand suitablecapacity submersible pump and wood wool fitted in frame made from 25x25x3 mm angle iron and 25x25 mm size MS wire mesh net of 14swg dia fitted on both sides for supporting woodwool including suitable size top and bottom water tray made of 1.00 mm GIsheet 1000 watts speed control electronic regulator , suitbale size connection cable 3 core with copper conductor with moulded plug top , fan blade and all fixingaccessories complete all as specified and as directed.
130Taking down u/s and Supply and fix Exhaust fan motor with blade and frame heavy duty industrial exhaust fan (18 inch/450 mmwith IP 55 specification, rigid frame with rubber mounting for silent operation epoxy powder coated and better resistance to corrosion and acid alkali fumes , totally enclosed highly efficient copper wound motorincluding testing of motor, AC, 230/ 250 volts, Heavy duty and blades 450mm sweep, suitable for desert cooler of capacity 4500 CFM. Note The quoted rate shall include fixing of fan in side of desert cooler , clamp nut bolts, welding arrangement, etc
131S&F in repairs ofPVC connection 15 mm size with PTMT nut of length 450 mm complete all as specified and as directed by Engineer in Charge.
132S&F Metal front grill with selector switch and indicator bulb suitable for18 "/ 24 " desert cooler etc , fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
133NOTE: Contractor Shall not Submitted any RAR/Bill where amount of Work Done in FH Item Exceeds Work done in FL Item till the time all FL Items have been Executed.