Tender For Construction Of Vfd Building And Combined Station Works Including Air Conditioning System For Variable Frequency Drives (Vfds) Of Kdpl And Krpl Mainline Motors At Wrpl, Koyali, koyali-Gujarat

Indian Oil Corporation Limited-IOCL has published Tender For Construction Of Vfd Building And Combined Station Works Including Air Conditioning System For Variable Frequency Drives (Vfds) Of Kdpl And Krpl Mainline Motors At Wrpl, Koyali. Submission Date for this Tender is 30-12-2022. Industrial Drive Tenders in koyali Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

35218519
Tender For Construction Of Vfd Building And Combined Station Works Including Air Conditioning System For Variable Frequency Drives (Vfds) Of Kdpl And Krpl Mainline Motors At Wrpl, Koyali
Open Tender
Indian
Gujarat
koyali
30-12-2022

Tender Details

Construction Of Vfd Building And Combined Station Works Including Air Conditioning System For Variable Frequency Drives ( Vfds ) Of Kdpl And Krpl Mainline Motors At Wrpl, Koyali

Key Value

Document Fees
Refer document
EMD
INR 230700.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of VFD Building and Combined Station Works including Air Conditioning System for Variable Frequency Drives (VFDs) of KDPL and KRPL mainline motors at WRPL, Koyali
Sl. No. Item Description
1Electrical items
2Installation including transportation from owner desginated location, testing and commissioning of owner supplied Variable frequency drives on foundation channels including aligning, levelling, grouting etc., Making all the inter- connections with HT Breakers, hot standby PLC of VFD system & Motors for incoming/outgoing/ Power / control cables (All as applicable). Making holes for cable entries, if required and blinding the spare cable entry holes, with materials i.e. WP Cable glands, end lugs, earthing of VFD board, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. (Note: Commissioning assistance (only supervision) shall be provided by supplier of the VFD.)
3Factory built Floor mounted Packaged Air conditioning units: Supply, installation, testing and commissioning of Factory built Floor mounted Packaged Air conditioning units of approved make and model, comprising of multiple Scroll compressors, DX evaporator coil with cross hatched high efficiency copper tubes, thermostatic expansion device & distributor, DIDW/DX centrifugal blower with 3 phase drive motor, air-cooled condenser suitable for 45 deg C ambient temperature etc. Each package unit with not less than 550 CFM(Cubic feet per minute)/TR complete with microprocessor control. Each Evaporator unit shall be with Scroll compressors, controls such as contactors, over load protector for all motors, HPLP cutouts, single phase preventor, evaporator coil, evaporator fan complete with motor, adjustable belt drive, insulated drain pan assembly, super-heat expansion valve, refrigerant filter drier with shut off valves and dry-fabric cleanable type filter. Condensing unit shall comprise of condenser coil and condenser fan motor etc. The evaporator unit and condensing unit will be factory assembled in a compact heavy gauge steel cabinet, duly painted, complete with all materials, labour, tools, tackles, consumable etc., including pressure testing & charging of refrigerant gas/ oil, fixing of isolation valves, catchall drier/filter, Canvass connection, Machine outlet dampers, Vibration isolation pads, lifting-shifting & positioning at appropriate location (minimum configuration n Working + 1 Stand-By total n+1 unit). Detail calculation for ariving at value "n" is to be submitted for approval from the AC manufacturer. Tentative required data is given in the technical specifications. Package type Air Conditioning Units (Required capacity to be indicated).
4Hard Drawn refrigerant Copper piping: Supply & installation of Hard Drawn refrigerant Copper piping (16 / 19 guage) with necessary insulation to interconnect indoor and outdoor units.
5GI DUCTING - Supply, Fabrication, installation and testing of sheet metal ducting complete with flanges. While taking duct measurements, vanes, collars, etc., will also be measured and accounted for 22 guage
6DUCT THERMAL INSULATION: Duct Thermal Insulation with aluminium foil faced Nitrile rubber of 9 mm thickness.
7Supply, installation, testing and balancing of aluminum powder coated grilles/Diffusers (as required based on site feasibility): Extruded Aluminium Powder coated supply / return air grilles with Volume control dampeners.
8The volume control shall be made out-off 16G Galvanized sheet blades, with 16G Galvanized sheet frame, Galvanized steel linkage, with flange on both sides, with manual adjustment handle.
9Drain piping: Supply & Installation of PVC insulated 40 mm dia drain piping.
10Drain piping: Supply & Installation of PVC insulated Condensate 32 mm dia drain piping.
11Duct Accoustic Lining: Supply & installation of 25 mm thick fibre glass (density 32 Kg/cbmt) covered with RP Tissue paper for thermal insulation
12Supply, installation, testing and aligning fresh air arrangement with Bird Screen & Volume Control Dampener (Provision for utilisation, if required).
13MS Stands for mounting of Outdoor Units: Supply & Installation of MS Stands for mounting of Outdoor Units.
14Electrical armoured cabling for Indoor Units & Outdoor Units: Supply & Laying, termination, connection of interconnecting electrical armoured cabling for Indoor Units & Outdoor Units.
15Insulation: Under dake Insulation with Fire resistence TF Quality Poly Styrene 50mm thick ( density 32 Kg/cum ) Fire resistant type.
16Bare Fire Control Damper: Bare Fire Control Damper for SA & RA Duct
17Pressure Testing & Charging of Refrigerant Gas: Pressure testing and charging of R-407C/R33
18Supply of LT Cables FRLSH - Aluminium Cables-1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40% AL,4CX25 mm²,A2XFY
19Supply of HT 33 KV, 11 KV & 6.6 KV cables - Screened, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvaznized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40% AL 3CX240 mm² 6.6 KV
20Supply of LT Cables FRLSH - Aluminium Cables-1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40% AL,3.5CX50 mm²,A2XFY
21SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges: RUBBER HAND GLOVES: Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark.
22SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges:
23INSULATING MATS - Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elastomer mats as per specifications:
24Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and materials complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
25WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to original condition and disposing off excess materials (within the work site) job complete in all respects including the cost of labour, tools, materials, load, lift hire charges of equipments, if any, complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
26Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD above 20 mm and upto 40 mm
27Cable Laying - Laying of all type of cables HT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables HT
28Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Installation, laying of Cat 6 LAN Cables in 16 mm/ 25 mm/ 32 mm PVC conduits from network switch through ceiling/wall/trench and post-laying end to end testing of cables. The job includes supply, installation & fixing of Duplex (2 port) Face plate (Network I/O point) (white/ cream colour) for Local Area Network including RJ45 I/O, modular plate & switch box/ gang box for fixing the face plate & accessories, supply and installation of PVC Conduits, all required materials such as fixing clamps, screws, cable straps, tags etc. as required complete in all respects as per specifications & scope of work, drawings and directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, materials etc.
29Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: 20 Pair Armoured PIJF Underground Telephone Cable
30GI CABLE TRAY: Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
31SAND FILLING: Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
32BRICK SOLING: Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
33CABLE MARKER: Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, backfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
34HT CABLE JOINT: Making straight-through joint on 6.6 / 11 KV Aluminium/Copper XLPE/PVC insulated armoured screened cable, including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem / M-seal / 3M), materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: For cables of size upto 3 core x 400 sqmm
35HT Cable Termination (6.6/11 KV) - Supply, termination and connection of XLPE cable termination kit (indoor type), heat shrinkable sleeve type of Raychem/M-Seal/CCI make with all accessories, including cutting (tools and accessories for termination should meet the selected standards), stripping of cable insulation providing copper cable end lugs and cable glands as required, restoration of insulation, supplying and providing the cable supporting clamps, straps, cable tags connection to the terminals of HT panel, VFDs, Isolators, transformer, DG,MLPU/Booster pump motors etc., earthing of armouring, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: HT Cable of size upto 3Cx240 sq. mm
36EARTH ELECTRODES: Supplying, installation, testing of GI earthing electrode, including the supply and installation of the CI cover, charcoal /special backfill etc. and construction of chamber; complete as per drawings,specifications and directions of the Site Engineer, Including the cost of all labour, tools, materials etc. complete in all respects.
37Supply, installation, testing of earthing system consisting of 3 earth pits of perforated GI pipes earthing electrodes and copper plate terminal block including construction of chamber using cement concrete with earthing pit cover and frame, supply of charcoal, salt etc including supply of interconnecting cables / strips including necessary welding etc complete as per drawings, specifications and directions of the site engineer, including cost of tools, materials etc complete in all respects as per drawing The job shall also include testing of each earth pit and the entire earthing system on whole. (Note: Earthing for field instruments shall be provided from Station earth grid covered in Electrical SOR.)
38EARTHING PLATE: Supply & Installation of G.I. earthing plate as per standard drawing outside the buildings. The item also includes grouting of the plate as shown in the drawing. The item should be complete in all respect including all materials, tools, tackels etc. and as per direction of EIC / Site engineer.
39EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect: 50 mm X 6 mm G.I. earthing strip
40EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect:
41Supply, erection & installation of cable conduits made up of GI pipes of medium class "B" subject to owner"s approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge: 50mm
42Supply, erection & installation of cable conduits made up of GI pipes of medium class "B" subject to owner"s approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge: 100mm
43Supply, erection & installation of cable conduits made up of GI pipes of medium class "B" subject to owner"s approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge: 150mm
44Supply and installation of shock treatment chart framed in good quality glass in English / Hindi / Local Language.
45Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/6.6 KV as per IS 255 including fixing on the wall with all the required hardware etc. complete in English / Hindi/ Local Language.
46STAINLESS STEEL INSCRIPTION PLATE: Supply and installation of approved quality stainless steel name inscription plates including anodising, engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-charge including the cost of all labour, tools etc.
47Point wiring - Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor: 1 light point controlled by 1 switch
48Point wiring - Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor: 2 light points controlled by 1 switch
49Point wiring - Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor: 3 light points controlled by 1 switch
50Wiring for 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socket and 20/10 A modular switch (1 plug point per circuit) as per specifications and drawings
51Wiring for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 5 pin 6A modular socket and 10 A modular switch (1 plug point per circuit) as per specifications and drawings.
52Point wiring for power plug point with 4 sq.mm stranded PVC insulated copper wire including earthing the third pin with 2.5 sq. mm copper insulated earthing wire complete with supply and fixing of recessed mounted industrial type 3 pin 32 A metal clad socket and plug, 20A MCB (Motor duty) housed in a 16 gauge M.S. Box
53Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: Type II Distribution Board: Double Door EURODB of Havells or approved make having Copper bus bar 100 A TPN, 1 Incomer 32 A TPN MCB with 32 A TPN RCCB (Senstivity 100 mA) alongwith 6 numbers 6 A SP MCB + 6 number 16 A SP MCB as per specification.
54Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: Type III Distribution Board: Double Door EURODB of Havells or equivalent approved make having bus bar 200 A TPN, 1 Incomer 125 A FP MCB Isolator with 125 A FP RCCB (Senstivity 100 mA) alongwith 3 numbers 63 A TPN MCB as per specification.
55Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: Type IV DIstribution Board: Double Door Translucent Euro DB of Havells or approved make, having 100 A TPN Copper Bus bar, 1x63 A TPN MCB , 1x63 A RCCB (100 mA Sensitivity), 9x6A SP MCB & 6x20 A SP MCB as per specification
56Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: Type V Distribution Board: Double Door, EURO DB of Havells or equivalent approved make having 200 A TPN Bus Bar, 1 x 100 A FP MCB, 1x100 A FP RCCB (100 mA Sensitivity), 9x32 A SPN Motor duty MCB as per specification.
57Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: Critical Light DB: Euro DB DBOXx of Havells or equivalent make complete with bus bar, neutral links, earth links and 1 x 6 A MCB SPN & 7x2 A SPN MCB
58Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: Surface mounting Plug & Socket DB complete with 63 A TP MCB, with neutral link for VFD AC"s
59PVC Conduit pipes - Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providing necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including making good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge including cost of all labour, materials etc.: 32mm
60Decorative Light fittings - Supply, installation, connection, earthing and testing of the following fittings, including supply and installation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other required materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from the approved make list given in the specifications: LED light fittings, Recess mounting type, Sereno LED-RC869B LED 30S-6500 PSE W30L120 D8 or equivalent approved make with LEDs: Supply and fixing of recess mounted weather proof light Sereno LED-RC869B LED 30S-6500 PSE W30L120 D8 or equiavlent approved make with LEDs, 42 W or more, having 2950 lumens or more output. LED Fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved make.
61Decorative Light fittings - Supply, installation, connection, earthing and testing of the following fittings, including supply and installation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other required materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from the approved make list given in the specifications: LED light fittings with LEDs, Sereno LED-Suspended-SP824 P LED 30S-5000 GR OD or approved equivalent:Supply and fixing of surface mounted weather proof light SP824 P LED 42 W having 2950 lumens output fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved make.
62Supply fixing and erection of modular cable transit (MCT) for cable entry to building in proper frame including supply of peelable type, spare block, stay plates compression wedgs etc. with all accessories as per specification considering 20 % minimum spare in each module to be installed as per instruction of Engineer in charge/ site engineer: Galvanised mild steel frame with packing space of Min.120x240 mm with multi diameter blocks and accessories with peeling off arrangement to adjust cable size from 3.5mm to 99mm outer dia
63Supply fixing and erection of modular cable transit (MCT) for cable entry to building in proper frame including supply of peelable type, spare block, stay plates compression wedgs etc. with all accessories as per specification considering 20 % minimum spare in each module to be installed as per instruction of Engineer in charge/ site engineer: Galvanised mild steel frame with packing space of Min.120x180 mm with multi diameter blocks and accessories with peeling off arrangement to adjust cable size from 3.5mm to 99mm outer dia
64Lightining Arrestor: Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 2 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. complete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the main earthing grid.
65CABLE SUPPLY & LAYING : Supply, laying & testing of XLPE insulated, FRLS property on outer sheath, PVC sheathed armoured 1.1 kV grade control & power cables with copper / Aluminium conductor conforming to IS 7098 (P-1) latest edition including supply of lugs, glands, consummables, tools, tackles, labour complete. Note: Cable length shall be measured after laying. 16C x 2.5 sq. mm. Cu. Control cable
66CABLE SUPPLY & LAYING : Supply, laying & testing of XLPE insulated, FRLS property on outer sheath, PVC sheathed armoured 1.1 kV grade control & power cables with copper / Aluminium conductor conforming to IS 7098 (P-1) latest edition including supply of lugs, glands, consummables, tools, tackles, labour complete. Note: Cable length shall be measured after laying. 6C x 1.5 sq. mm. Cu. Control cable
67Dismantling/ pulling out the LT/ HT, PVC/ XLPE, power/ control/ telephone/ computer, armoured/ unarmoured cables of various voltage grades/ types/ sizes/ makes from the trench (upto 1.5 metres deep)/ pipes/ structures/ racks or trays, rolling it into empty drums, returning the filled up cable drums to the store/ another site including transportation of empty drums from stores to site and filled up cable drums from site to stores/ another site etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials. Job includes declamping, rerouting and relaying of cable for reglanding etc. Overall diameter >55 MM but upto 75 MM
68Dismantling of switch fuse unit/ fuse gear unit/ DB/ any other control without using heavy lifting equipments without any damage and returning it toour Stores all complete with labour and materials as per the direction of the Engineer-in-Charge. Upto and including 10 Kg
69Dismantling of switch fuse unit/ fuse gear unit/ DB/ any other control without using heavy lifting equipments without any damage and returning it toour Stores all complete with labour and materials as per the direction of the Engineer-in-Charge. Above 10 Kg and upto 50 Kg
70Dismantling of switch fuse unit/ fuse gear unit/ DB/ any other control without using heavy lifting equipments without any damage and returning it toour Stores all complete with labour and materials as per the direction of the Engineer-in-Charge. Above 50 Kg and upto 100 Kg
71Dismatling of electrical wiring Electrical wiring (comprising of single or twin core PVC wires upto 6Sqmm and single earth wire upto 6SWG) along with its connected accessories like junction boxes, surface conduits, battons, switch boards etc.
72Dismantling of following light fitting items without damage and returning them to our stores or any other place or site within the premises as decided by the Engineer-in-Charge. all complete with labour and materials including dismantling of supports of any type, down rods, chokes, condensers and any other accessories as per the directions of the Engineer-in-Charge. Tube light fittings of all types/makes including single/double tube light fittings and bulk head fittings installed at different places in free zones including LED tubelights.
73Dismantling of following light fitting items without damage and returning them to our stores or any other place or site within the premises as decided by the Engineer-in-Charge. all complete with labour and materials including dismantling of supports of any type, down rods, chokes, condensers and any other accessories as per the directions of the Engineer-in-Charge. Dismantling of all types & sizes of ceiling fans with down rod and regulator and exhaust fans of sweep 350/450 mm alongwith shutter, frame etc. without damage and returning them to our stores or any other place or site within the premises as decided by the Engineer-in-Charge. all complete with labour and materials including dismantling of supports of any type, down rods, condensers and any other accessories as per the directions of the Engineer-in-Charge.
74Dismantling/ pulling out the LT/ HT, PVC/ XLPE, power/ control/ telephone/ computer, armoured/ unarmoured cables of various voltage grades/ types/ sizes/ makes from the trench (upto 1.5 metres deep)/ pipes/ structures/ racks or trays, rolling it into empty drums, returning the filled up cable drums to the store/ another site including transportation of empty drums from stores to site and filled up cable drums from site to stores/ another site etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials. Job includes declamping, rerouting and relaying of cable for reglanding etc. Overall diameter upto 35 MM
75Dismantling/ pulling out the LT/ HT, PVC/ XLPE, power/ control/ telephone/ computer, armoured/ unarmoured cables of various voltage grades/ types/ sizes/ makes from the trench (upto 1.5 metres deep)/ pipes/ structures/ racks or trays, rolling it into empty drums, returning the filled up cable drums to the store/ another site including transportation of empty drums from stores to site and filled up cable drums from site to stores/ another site etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials. Job includes declamping, rerouting and relaying of cable for reglanding etc. Overall diameter > 35 MM but upto 55 MM
76Dismantling/ pulling out the LT/ HT, PVC/ XLPE, power/ control/ telephone/ computer, armoured/ unarmoured cables of various voltage grades/ types/ sizes/ makes from the trench (upto 1.5 metres deep)/ pipes/ structures/ racks or trays, rolling it into empty drums, returning the filled up cable drums to the store/ another site including transportation of empty drums from stores to site and filled up cable drums from site to stores/ another site etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials. Job includes declamping, rerouting and relaying of cable for reglanding etc. Overall diameter > 75 MM
77LT Cable Termination: Providing end termination of power/control cable including cutting, sripping, fixin lugs, crimping/soldering, with cast resin end termination, restoration or insulation/ clamping of cable, tagging with aluminium tag, earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-charge 4 X 25 sqmm
78ACDB for Control circuit Supply, installation, testing and commissioning of surface/recess mounting, vertical type, compartmentalised, 415V, TPN MCB distribution board of sheet steel, 1.6mm thick, duts protected, duly phosphatized and painted, inclusive of 200A tinned copper busbars, earthbar, common neutral link, din bar for mounting MCB"s detachable gland/ knock out plates and with built in loose wire box and superior make terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of PVC inslated copper wires between the busbars and the MCB"s as well as the incomer and upto the terminal connectors/neutral link and ready for installation, of 8 Way (but without MCB"s and incomer) as required with IP 42 protection plus acryclic door.
79Incomer MCB Supply of 200Amps, 36kA breaking capacity 4 pole MCCB with thermomagnetic release along with terminal spreaders as per direction of Engineer-in-charge
80Distribution MCB Supplying of 32 amps rating, 3 Pole MCB, "C" curve, 10kA breaking capacity as per direction of Engineer-in-charge
81Civil Items:
82Aluminium work for door/window/ventilator/partition: Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : For fixed portion : Powder coated aluminium (Minimum thickness of powder coating 50 micron)
83Aluminium work for door/window/ventilator/partition: Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required. [Note: Fittings shall be paid for separately] : Powder coated aluminium (Minimum thickness of powder coating 50 micron)
84Glazing in AL door/window/ventilator/partition: Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-Charge. [Note: Cost of aluminium snap beading shall be paid in basic item] : With float glass panes of 5.50 mm thickness
85Double action hydraulic floor spring: Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per directions of the Engineer-in-Charge. : With stainless steel cover plate minimum 1.25 mm thickness
86Aluminium tubular handle bar: Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per directions of the Engineer-in-Charge : Powder coated (Minimum thickness 50 micron) aluminium tubular handle bar
87Brass Locks: Providing and fixing brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
88Aluminium casement windows fastener: Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete : Powder coated (Minimum thickness 50 micron) Aluminium
89Aluminium round shape handle: Providing and fixing aluminium round shape handle of outer diameter 100 mm with SS screws etc. complete as per directions of the Engineer-in-Charge : Powder coated (Minimum thickness 50 micron) Aluminium
90Sun Control Film: Providing and fixing, on fixed glazing/ doors/ window panes, sun control film "HP NATURAL 35 SAFETY COMBINATION FILM-4Mil" of M/s. GARWARE or approved equivalent make and shade, all complete as per manufacturer"s specification and as per directions of the Engineer-in-Charge.
91Granite work-For kitchen platforms & like: Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite (of any colour and shade) for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels : Area of slab up to 0.50 sqm
92Burnt Terracota Tiles : Providing and laying Burnt Terracota Tiles 12 mm thick for facia, over walls, sloping RCC Roofs etc. at all levels and locations laid over and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colour as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.
93Elevational Brick Tiles : Providing and fixing 12 mm thick Elevational Brick Tiles for facia, vertical face of walls, etc. at all levels and locations laid over and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colour as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specification and directions of the Engineer-in-Charge.
94CONCRETE WORK : PCC-Up to Plinth Level: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources]
95CONCRETE WORK : PCC-Up to Plinth Level: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources]
96Pre-cast CC-In Kerbs, Edgings & Like: Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]
97Pre-cast CC-In Kerbs, Edgings & Like: Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete : Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 Kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
98Making plinth protection 50 mm thick of cement concrete 1:3:6 [1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources] over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
99Open Surface Drain: Construction of second class brick masonary open surface drain (Size: 200mm wide & 200mm average depth) in cement mortar 1:4 laid over a bed of 150mm thick cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including making haunches and providing 15mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement inside and its top and exposed surfaces, including excavatioin, disposal of the surplus earth up to any lead and lift as per standard design and drawing, complete in all respects inclusive of cost of all labour, materials, carriages, excavation and refilling, curing etc., as per specifications and directions of the Engineer-in-Charge.
100Earth work: Surface Excavation Earth work in surface excavation (not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan) in all kinds of soil including getting out and disposal of excavated earth up to all lead and lift, as directed by the Engineer-in-Charge.
101Excavation over areas: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed by the Engineer-in-Charge : In all kinds of soil
102Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m.
103Sand filling in plinth/ floors Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
104Filling excavated earth in low lying areas Filling the excavated earth to required grade, level & profile in low lying areas including watering, ramming, compacting at optimum moisture content to 90% of Proctor"s density consolidation by rolling with 8 to 10 tonne power roller in layers not exceeding 20 cm thickness, including clearing the area by cutting of shrubs, bushes, grass, vegetation, debris etc. stacking and disposing out of plot area to an unobjectional area as directed by Engineer-in-Charge complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge.
105Filling selected earth/ moorum Supplying and filling selected earth/ moorum (excluding black cotton soil) from Contractor"s own borrow areas including royalty, with all leads and lifts in low laying areas and filling to required grade and level including watering, compacting at optimum moisture content to 90% of Proctor"s density, consolidation and rolling with 8 to 10 tonne power roller in layers not exceeding 20 cm thickness, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
106Anti-termite Treatment (Pre-Construction) Supplying all labour, materials, tools, chemicals, spray pumps etc. for making pre-constructional anti-termite treatment & creating a continuous chemical barrier under & all round the column pits, wall trenches, top surface of plinth filling, junction of wall & floor, along the exterior perimeter of the building, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. [Note: Total plinth area of the building shall be measured for payment].
107Plaster 1:3 in coarse sand (with neat cement coat): Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement : 15 mm cement plaster 1:2 (1 cement : 2 stone dust) on the rough side of single or half brick wall.
108Plaster 1:3 in coarse sand (with neat cement coat): Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement : 6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand)
109Providing & fixing galvanized chicken wire net 20 Gauge, 20 mm mesh size in plastering work at the junction of RCC Columns/ Beams & brickwork as directed by the Engineer-in-Charge.
110Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
111Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
112Synthetic enamel paint: Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
113White cement based putty on wall: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
114Premium acrylic emulsion paint (Interior Grade): Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour : Two coats
115Flat brick soling: Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 laid to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
116PCC Flooring (25mm thick): Providing and laying cement concrete flooring 25 mm thick of mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregates 12.5 mm nominal thickness), laid monolithically over base of concrete in panels at all locations and heights including treads of steps, nosing, landing slab etc. and finished with a floating coat of neat cement @ 2.20 Kg of cement per sqm of flooring, supplying and fixing 1.5 mm thick aluminium strips for full depth, chequering in floor finish if required, rounding, sloping, curing, finishing, preparation of slab, steps, etc., complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. [Note: Payment for base concrete shall be made under relevant item].
117Flame finish Granite Stone Flooring: Providing and laying flamed finish Granite stone slab (Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent) flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
118Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
119Kota Stone-In Skirting/steps/dado: Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
120Brickwork (Non Modular)-In foundation & plinth: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
121Brickwork (Non Modular)-In Superstructure: Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
122REINFORCED CEMENT CONCRETE : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 [1 cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]
123REINFORCED CEMENT CONCRETE : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement, with : 1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources]
124REINFORCED CEMENT CONCRETE : Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
125REINFORCED CEMENT CONCRETE : Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform
126Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
127Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts
128Reinforcement for RCC-Upto plinth Level: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level : Thermo-Mechanically Treated bars of grade Fe-500D or more
129Reinforcement for RCC-Above Plinth Level:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level : Thermo-Mechanically Treated bars of grade Fe-500 D or more
130Drip course/Groove/Moulding in RCC projections: Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
131Cement Concrete Gola: Providing gola 75x75 mm (in 75x75 mm deep chase) in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design.
132Cement Concrete Khurra: Making Khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
133Rockwool Insulation for VFD Room: Providing and fixing thermal insulation system for roof of VFD Room consisting of G.I. channels of size 50x50x5 mm thick all around periphery and intermediate runner of composite unit made of two channel sections at 1220 mm centre to centre fixed with G.I. dash fastners 6 mm x 40 mm x 60 mm, fixing 50 mm thick Rockloyd Rockwool Slabs manufactured by M/s LLOYD INSULATIONS (INDIA) LIMITED or any other approved equivalent brand of density 48 Kg/cum laminated with 0.05 mm aluminium foil on facing side having K-Value of 0.028 WmK on to the G.I. channels with neccessary G.I. wire netting & 20 mm S.T. screws at 150 mm c/c, fixing Gypsum Board or E-Board on to the G.I. channels with self tapping screw, necessary beading at joints including cleaning the soffits, making openings for light fittings etc. with suitable peimeter framing all complete as per manufacturer"s recommendations and directions of the Engineer-in-Charge.
134Rainwater Pipes (uPVC)-110mm Dia: Providing and fixing on wall face Unplasticised Rigid PVC (uPVC) rainwater pipes (110 mm diameter, single socketed) conforming to IS:13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion.
135Rainwater Pipe Fiittings (UPVC): Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion : Coupler (110 mm)
136Rainwater Pipe Fiittings (UPVC): Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion : Single Push-fit Coupler (110 mm)
137Rainwater Pipe Fiittings (UPVC): Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion : Bend- 87.5 Degrees (110 mm)
138Rainwater Pipe Fiittings (UPVC): Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion : Shoe - Plain (110 mm)
139Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non-combustible as per BS 476:1970 (Part-4) and Light Reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross-T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall SS screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge : Providing and fixing LUXALON 75C & 225C un-perforated Aluminium panel coloured ceiling manufactured by M/s. HUNTER DOUGLAS INDIA or any other approved equivalent brand, each panel consisting of 75/225 mm wide x 15.5 mm deep and 0.5 mm thick with bevel edged panel made from enamelled corrosion resistance aluminium alloy AA-5050 (Al.Mg), each panel to abut each other with a narrow "V" groove, clipping with a baked enamelled aluminium panel carrier of 32 mm wide x 39 mm deep x 0.95 mm thick in standard length of 5 metres made of double baked enamelled aluminium alloy AA-5050 (Al.Mg) black with cutouts to hold the panels in a module of 75 mm closed at a distance of 1.25 metre, each panel carrier suspended by means of G.I. suspension rod 4 mm diameter and a galvanised supsension spring clip at a distance of 1.7 metre centre to centre, making openings for light fittings etc. with suitable peimeter framing all complete as per manufacturer"s recommendation and directions of the Engineer-in-Charge. [Note: Measurement shall be made wall to wall without any deduction for openings, for payment purpose].
140Fixing fly proof wire gauze to window: Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete : Stainless Steel (Grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides.
141Steel work (rolled/built up section) with epoxy paint: Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, claddings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cutting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. including preparation of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying & applying painting with two coats of epoxy paint "EPILUX 155 High Build Enamel over a coat of "EPILUX 610" Primer of M/s BERGER or any other approved equivalent make as per manufacturer’s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of concrete work).
142Liquid Elastomeric Waterproofing: Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per directions of the Engineer-in-Charge.
143Water proofing compound: Supplying and using water proofing compound like CICO, PUDDLE or any other approved brand with Cement Plaster/ CC/ RCC complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
144Flush door shutters (Non-decorative): Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
145DISMANTLING & DEMOLISHING : Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations] : Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
146Demolishing brick work in cement mortar manually or by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations]
147Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by the Engineer-in-Charge, beyond 50 m initial lead, for all leads including all lifts involved.