| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-01-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 16-01-2023 |
| 2 | 27-12-2022 | AMENDMENT TO BOQ | BOQ | 09-01-2023 |
| 3 | 27-12-2022 | OTHER CORRIGENDUM | Other | 09-01-2023 |
| 4 | 27-12-2022 | DATE CORRIGENDUM_2 | Date | 09-01-2023 |
| 5 | 20-12-2022 | Date Corrigendum | Date | 07-01-2023 |
| Sl. No. | Item Description |
| 1 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all asdirected. |
| 2 | Taking down timber roof trusses, coupled rafters or trussed beams, Clear span Above 4 metres & upto 8 metres complete all asdirected. |
| 3 | Dismantling posts or struts (wood, steel or R.C.C.) any section,Posts embedded inConcrete, brick work, masonry, etc.including taking out embedded portion and making good disturbed ground complete all asdirected. |
| 4 | Dismantling timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, unframed work complete all asdirected. |
| 5 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as directed. |
| 6 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as directed. |
| 7 | Demolition of brick work built in cement mortar of any descriptionincluding removing debries of the site,complete all as directed. |
| 8 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in CM 1:6complete all as specified and directed. |
| 9 | M&L Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed. |
| 10 | M&L 15mm thick rendering with cement mortar (1:4)on fair faces of brick work in two layers(10mm&5mm) seperately mixed with water proofing compound in top layer as per manufacturer\"s instructions and finishing the surface even and smooth without using extra cement complete all as specified and as directed.Note:- WPC shall be measured and paid seperately under appropiate item. |
| 11 | Supply only liquid water proofing compound complete allas specified and as directed. |
| 12 | M&L Rendering 10 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished surface even and fair without using extra cement complete all as specified and as directed. |
| 13 | M&L prepration of new plastered surfaces ofwall applying two coat of oil emulsion distemper overa coat Chalk whiting, on plastered surfaces, preparatory to distempering complete allas specified and as directed |
| 14 | M&L prepration of new plastered surfaces ofwalls and applying two coats of weather coat exterior emulsion paint over a coat of primer complete all as specified and directed. |
| 15 | S&F framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed baluster; walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 16 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and as directed.. |
| 17 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed. |
| 18 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 19 | S&F rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment. conforming to Fe 290 Gde E-165 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 20 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or squarenut, length of bolt exc 5cm but n exc 10cm long, Diameter of neck in 11 to 15mm, complete all as specified and directed |
| 21 | M&L preparing new Steelsurfaces of any description, not otherwise describe over 10cm width or girth and applyingtwo coats of synthetic enamel paintcomplete all as specified and as directed. |
| 22 | Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each. complete all as directed. |
| 23 | Taking down chowkat with shutter without taking off shutter from the frame exc 1.5 Sqm n.exc 4 Sqm each complete all as specified and as directed. |
| 24 | S&F 1.25mm thk Pressed steel frames for doors, Size of frame 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, |
| 25 | S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sidescomplete all as specified and directed. |
| 26 | S&F Factory made second class hardwood 35mm thickGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 27 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and as directed. |
| 28 | S&F 150mmlong Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 29 | S&F 300mm aluminium alloy sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy fixed complete all as specified and as directed. |
| 30 | S&F 100mm size Butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed. |
| 31 | S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed. |
| 32 | S&F in repair 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame workcomplete all as specified and directed |
| 33 | S&F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, Width of flaps (when open) in 30mm complete all as specified and directed. |
| 34 | S&F 100mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 35 | M&L for preparing new wooden surfaces of any description, not otherwise describe over 10cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 36 | S&F Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators, partitionswith one or more rebates including joining cleat for fixing etc. complete all as specified and directedNote:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 37 | S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium windows/ventilators/partitionsany type including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts etc as required. complete all as specified and directedNote:- (i) Labour charges for fixing of glass/wire guage/aluminum grills is inclusive in the unit rate quoted. Glass/Wire Guage/aluminum grills shall be measured and paidseperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 38 | Supply only 4mm thick plain sheet, frosted one side, ordinary quality fixed with Aluminum frame work n. exc 0.5 sqm in each pane complete all as specified and as directed. |
| 39 | M&L Reinforced Cement Concrete Work (Nominal Mix)1:2:4 type B1 using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed |
| 40 | Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.rough finished surfaces of concrete flat complete all as specified and directed.complete all as specified and directed. |
| 41 | M&L Reinforced Cement Concrete Work (Nominal Mix)1:2:4 type B1 using 20mm graded stone aggregate as inSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed |
| 42 | Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)rough finished surfaces of concrete flat complete all as specified and directed.complete all as specified and directed. |
| 43 | M&L, Mild steel TMT bars 10mmdia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopingfor columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 44 | M&L, Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hoopingfor columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 45 | S&F Anodised aluminium snap grid frame work for false ceiling(Size of grid 605 x 605mm)complete all as specified and as directed. |
| 46 | M&L 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to GI/Aluminiumframework with screws complete all as specified and as directed. |
| 47 | Demoliation Cement concrete (unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as directed. |
| 48 | M&L forSand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 49 | M&L, hard core of broken stone or boulders, gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed |
| 50 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified and as directed. |
| 51 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed. |
| 52 | M&L for light shade vitrified ceremic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exc 0.36 Sqm in floors etc set and jointed :in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer 1:6 complete all as specified and as directed. |
| 53 | M&L Non skid coloured tiles7 to 8mm thick(square/ rectangular) area of each tiles exc.0.11 sqm but not exc 0.18 sqm in flooretc set and jointed in neat cement slury over and including cement screed 15 mm thick1:6 complete all as specified and as directed. |
| 54 | M&L Coloured glazed ceramic tiles 300 x 450 x 7 mm thick in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing with CM (1:4) complete all as specified and as directed. |
| 55 | M&L Granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20mm thick backing layerin cement mortar 1:4 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed. |
| 56 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 57 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete asper specification & drawing as specified in SSR Part I, Section 8 and as directed. |
| 58 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 59 | S&F 125mmlong Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 60 | S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed |
| 61 | S&F 150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 62 | S&F 15mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors, including necessary taking down of exsisting old pipe complete allas specified and as directed. |
| 63 | S&F 20mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors, including necessary taking down of exsisting old pipe complete allas specified and as directed. |
| 64 | S&F in repair sinks made of stainless steellmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mmcomplete all as specified and as directed |
| 65 | S&F in repair Vitreous China, pedestal pattern white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device with and including 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flush pipe, 15mm bore PVC Connection with PTMT nut of length 600 mm complete all as specified and as directed. |
| 66 | S&F in repairs vitreous china wash basin, white, flat back, size550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed. |
| 67 | S&F in repair 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated,fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed |
| 68 | S&F Wall mixer 3-in-1 system with provision fot both hand shower and over head shower complete with 115mm long bend pipe, connection legs, wall flange (without hand and overhead shower)complete all as specified and as directed Make-JAQUAR CAT No-SOL-6281 or equivalent as approved by GE from list of approved makes. |
| 69 | S&Fin repair Brass chromium plated shower rose 125mm size with or without swivel joints, including fixing to steel pipe or union) for fixing with 15mm dia steel pipe complete all as specified. |
| 70 | S&F 15mm angular stop cock with wall flange all as specified and as directed make -JAQUAR CAT NO-FON-40053 or equivalent as approved by GE from list of approved makes. |
| 71 | S&F in repair, 15mm boreBib taps, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 72 | S&F Hand shower (health faucet)(ABS Body) with 8mm dia, 1.2 meter long flexible tube & wall hook all as specified and as directed Make-JAQUAR CAT No-ALD-CHR-573 or equivalent as approved by GE from list of approved makes. |
| 73 | S&F toilet paper holder all as specified and as directed Make-JAQUAR CAT No-AKP-35751P or equivalent as approved by GE from list of approved makes. |
| 74 | S&F in repairs 15mm bore stop valves fancy type cast copper alloy, chromium plated, screwed both ends including necessary fittings such as sockets for pipe or for union all complete as specified and as directed. |
| 75 | S&F in repair 32mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kg/ cm2 fixed as waste pipe complete all as specified and as directed. |
| 76 | S&F in repair 32mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kg/ cm2 laid in trenchescomplete all as specified and as directed. |
| 77 | S&F in repairs,15mm bore PVC Connection with PTMT nut of length 450 mm complete all as specified and directed |
| 78 | S&F in repair 20mm boregun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 79 | S&F in repair, 110mm UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 80 | S&F in repair, 110mm UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to laid in trenches or in floors complete all as specified and as directed. |
| 81 | S&F 110mm dia UPVC (SWR) bends of any radius complete all as specified and as directed. |
| 82 | S&F 110mm dia UPVC(SWR) junction single, (Single T) equal or unequal complete all as specified and as directed. |
| 83 | S&F 110mm dia UPVC (SWR) vent cowl complete all as specified and as directed. |
| 84 | S&F 75mm dia. PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 85 | S&F in repair , aluminum anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed |
| 86 | S&F in repair , chromimum plated soap dish of size 160mm x 160mm x 90mm fixed fixed with plugs with chromium plated brass screws complete all as specified and directed |
| 87 | S&F, PVC coated mild steel curtain rod20mm dia thickness not less than 0.75mm, fixed with curtain rod holder fixed in walls with screws and finials caps with 6 Nos of curtain ring per RMcomplete all as specified and directed.Note: Curtain rod holder and finials caps will be measured and paid seperately at Supply only rates) |
| 88 | Supply only stainless steel curtain holding braketsuitable for holiding 20mm curtain rod heavy duty complete all as specified and directed. |
| 89 | Supply only stainless steel finial end cap suitable for curtain rod of20mm dia as approved complete all as specified and directed. |
| 90 | S&F in repair 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed |
| 91 | M&L Post Construction Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed. |
| 92 | M&L Post Construction Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed. |
| 93 | M&L Post Construction Treatment at points of contact of wood work by chemical emulsion (in oil or kerosenebased solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed. |
| 94 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 95 | M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour codingdrawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etcincluding provision of 1.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LSH (ISI markd) with proper colour coding as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box of appropriate size suitable for modularswitch/ fittingssurfaced in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed and making good to the disturbed surfaceof wall/floor and matching with existing specifications, complete all as specified and as directed.Note:- Connections of cable with MCB\"s or bus bar shall be done through proper size copper/brassthimbles. |
| 96 | All as per item No 95 here-in-before but for one 6 amps socket out let point on the same board with other switches |
| 97 | All as per item No 95here-in-before but for one 6 amps socket out let point on independent board. |
| 98 | M&L surface point wiring complete for one socket outlet 15/16 Amps point modular on independent board with4.00 Sqmm single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) multistranded PVC insulated multistranded unsheated copper conductor cable FR-LS (ISI markd)with proper colour codingdrawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 4.00 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LSH (ISI markd) with proper colour coding as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box of appropriate size suitable for modularswitch/ fittingsfixed in walls, with modular back plate, top cover fixed surfaced to wall for housing switches, socket outlets, fan regulators etc duly earthed and making good to the disturbed surfaceof wall/floor and matching with existing specifications. Connections of cable with MCB\"s or bus bar shall be done through proper size copper/brassthimbles. all as specified and as directed. |
| 99 | S&F Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 100 | S&F Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed. |
| 101 | S&F Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 102 | S&F Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed. |
| 103 | S&F ceiling rose, PVC/ polycarbonate, isolated body, three terminals, complete all as specified and directed. |
| 104 | S&F stepped type modular electronic fan regulator 120 watt 2 module suitablefor 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed. |
| 105 | S&F Modular bell push, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 106 | S&F call bell ding dong typeAC Single pole 220/240 Volts, surface type complete all as specified and directed. |
| 107 | M&L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 108 | S&F LED lights fitting 1x 20 Watt, (or next nearer higher watt) 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 109 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 110 | M&L sub-main wiring alongwith earth wire of size of 2 x 6.00 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and PVC casing cappingmedium grade with accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including taking out old unserviceable submain wiring and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. |
| 111 | M&L sub-main wiring alongwith earth wire of size of 2 x 4.00 sq. mm + 1 x 2.5 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and PVC casing cappingmedium grade with accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including taking out old unserviceable submain wiring and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. |
| 112 | S&F Sheet metal enclosure for 4 wayVPTN Distribution Boards (DB’s), IP-43 doubledoor, with 200 amps rated bus bar, suitable for housing and including 63 Amps four pole 415 volts breaking capacity 16 KA fixed thermal and fixed magnetic setting as incommer and MCB\"s as outgoing including blanking plates as required andflush to wall surface complete all as specified and directed. Note : Incomming MCCB is demmed to included in the Unit Rate quoted and Outgoing MCBs measured and paid seperately under relevant item |
| 113 | S&F in repair, MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and directed. |
| 114 | S&FMCB, SPN, C Series 240 Volts, 40 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 115 | S&F in repair, LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 116 | S&F bracket suitable for fixing of security light fitting made out from 40mm bore GI pipe, medium grade 1.5 metre in length,made to shape as required, fixed to pole with MS flat iron clamp of size 25x4mm duly welded, bent to shape and making holes etc including preperation of surfaces and applying a coat of zinc chrome red oxide primer over MS flat iron surfaces complete including necessary nuts, bolts & washer etc as required and as specified and directed. |
| 117 | M&L Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connectedtoGI Earth Strip 25 x 4 mm drawn through and including GI Pipe 32 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level ofthe Building where Main Switch/DB situatedby means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismantaling old unserviceable onescomplete all as specified and directed. |
| 118 | M&L Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connectedtoGI Earth Strip 25 x 4 mm drawn through and including GI Pipe 32 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level ofthe Building where Main Switch/DB situatedby means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and directed. |
| 119 | Excavation in trenches, exceeding 1.5 meter and not exceeding 3min depthfor column & wall foundation, UG Cable, Pole foundation and getting out in soft/loose soil complete all as specified and directed. |
| 120 | Returning, filling in, including spreading,levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed. |
| 121 | Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed. |
| 122 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trenchcomplete all as specified and directed. |
| 123 | M&L for sand cushioning in cable trenches over & under the cable/ducts with river washed coarse sand (approved source), as per standard practice with proper compaction complete all as specified and directed. NOTE : Punned thickness shall be considered for payment as per para 19.75 of SSR Part-I. |
| 124 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35sq mm 3.5 core, laid in trenches/fixed on walls/pole, laid in ducts/pipe including suitable size glangs, lugsas required complete all as specified and as directed. |
| 125 | Supply and lowering of 80mm bore GI pipe Heavy duty, flanged end, column pipe(length of each pipe 3 mtrs)including jointing/making with cutting grooves at flange for passing submersible clamp including clamp, bolts nuts, washer and rubber gasket complete all as specified and directed. |
| 126 | S&F CI Reflux/ Non Return valve single door pattern with flanged ends PN-1.6 confirming to IS: 5312, ISI marked of size 80mm dia bore with bypass arrange ment including all fixing accessoriestype Cast iron flanged end with nuts, rubber gasket, bolts (full threaded), nuts & washers complete all as specified and as directed. |
| 127 | Supply, install and testing 5.5KW/7.5HP, 415 VOLTS, 3 PHASE, 50 Hz, electric driven submersible pump set mix flow type with high graded CI bowl, stainless steel shafts, bronze impeller etc of pump outlet dia 65mm capable to deliver 240-471 LPM, clear water at 26-61 meter head, complete including necessary connection including steel chain made out of 6mm dia (size 20mm x 38mm) with PVC coating of lenght eual to the lenght of column pipe for holding submersible pump set/column pipe including necessary MS holding clamps, nuts, bolts etc complete all as specified and directed. |
| 128 | Supply, laying and fixing and testing PVC insulated submersible copper cable 6Sqmm, 3 Core, flat LT 1100 volts grade cable, heavy duty copper conductor and overall served with an outer sheathed,fixed along the column pipeto connect pump set complete all as specified and directed. |
| 129 | Supply, installing, commissioning and testingof factory made LT Panel board, TPN, 415 Volts, cubical type, floor mounted, outdoor type, suitable for 415 volts AC, CPRI approved factory made, double door, dust and vermin proof IP 65, fabricated out of CRCA sheet of not less than 3.15mm thick with 2mm thick for internal compartment dully powder coatedtand supportedby 50 mm x 50 mm x 6 mm MS angle iron frame with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch andfuse and the panel board shall be provided with proper ventillation including suitable size of cable alloy aluminum busbar suitable with suitable connections from MCCB;s outgoing to main busbar shall be carried out with TPN aluminum busbar of suitable rating and connection from main busbar to out going MCCM;s (intake point) will be carried out with TPN aluminum busbar as per MCCB rating dully insulated and colour coded heat shrinkable sleeves and shall be rigidly mounted on suitable size of bridge insulatorsincluding necessary earth work and PCC foundation(type C2, 1:3:6) of minimum 0.35meter height positioned and fixed with suitable nuts, bolts, washers etc. to MC pedestal andcomplete all as specified and directed and comprising of the following :-BUS BAR:-(i) Aluminum Bus bar 200 Amps, supported on non hygroscopic fibre and brass screws for mounting: 4 Nos.(ii) INCOMMER:-(a) MCCB 63 Amps, 4 Pole, 50 Hz, 415 Volts with fixed thermal and fixed magnetic setting having rapturing capacity 16 KA -01 Nos(iii) OUTGOING:-(a) MCCB 63 Amps, 4 Pole, 50 Hz, 415 Volts with fixed thermal and fixed magnetic setting having rapturing capacity 16 KA -01 Nos(b) DOL Starter suitable for 3 Phase, 7.5 HP Submersible pump: 2 Nos(c) Indicating Lamp 240 Volts LED type, R, Y, B: Set of three (d) Digital Ammeter of size 100mm x 100mm, 0-300 Amps including CT having CTR 200/5, and Voltmeter 0-500 Volts SIF 96: 01 Nos |