Tender For Repairs / Replacement Of Perimeter Lighting, Various Type Of Notice And Sign Boards With Internal Electrification Work And Cooling Appliances, Voltage Stabilizer Including Geysers At Zakhama/Chakabama Military Station Under Age(I) Za, zakhama-Nagaland

Military Engineer Services-MES has published Tender For Repairs / Replacement Of Perimeter Lighting, Various Type Of Notice And Sign Boards With Internal Electrification Work And Cooling Appliances, Voltage Stabilizer Including Geysers At Zakhama/Chakabama Military Station Under Age(I) Za. Submission Date for this Tender is 30-12-2022. Electrification Work Tenders in zakhama Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

35213214
Corrigendum : Tender For Repairs / Replacement Of Perimeter Lighting, Various Type Of Notice And Sign Boards With Internal Electrification Work And Cooling Appliances, Voltage Stabilizer Including Geysers At Zakhama/Chakabama Military Station Under Age(I) Za
Open Tender
Indian
Nagaland
zakhama
30-12-2022

Tender Details

Repairs / Replacement Of Perimeter Lighting, Various Type Of Notice And Sign Boards With Internal Electrification Work And Cooling Appliances, Voltage Stabilizer Including Geysers At Zakhama / Chakabama Military Station Under Age ( I ) Zakhama.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : REPAIRS / REPLACEMENT OF PERIMETER LIGHTING, VARIOUS TYPE OF NOTICE AND SIGN BOARDS WITH INTERNAL ELECTRIFICATION WORK AND COOLING APPLIANCES, VOLTAGE STABILIZER INCLUDINGGEYSERS AT ZAKHAMA/CHAKABAMAMILITARY STATION UNDER AGE(I) ZAKHAMA.
Sl. No. Item Description
1S&F in repairs, main entrance board ( Dimension 600mm x 300 mm ) with suitable fixing/ hanging arrangements/frame,made ofHigh Quality acrylic sheet material of thickness 3 mm with Vinal cutting Red colour single side, Writing "NO ADMISSION EXCEPT ON DUTY" and the same in Hindi and regional language as per format and as directed by Engr-in-Charge.
2M&L for manufacture, supply and installation ofthe Back lit Glow sign board for Machinery History sheets/ Electric shock charts etcas per following Specifications:-: (a) Box: 1 The box size is approx3 feet x 2.5 feet. 2 The board frame should be made of MS Pipe 25x25x1.5 mm painted with one coat red oxide primer and 2 coat synthetic enamel paint. 3 Top, Bottom and Side cover shall be made of .45mm GI sheet with powder coating and Back side of the board shall be covered with .45mm plain GI sheet fixed with rivet and screws. (b) Lighting/Illumination: 1. Minimum one LEDtube light set is to be provided per five Square feet of board area. 2. Complete tube light set is to be provided. Tube lights shall be of reputed make. 3. Only copper wiring will be used. (c)Flex: 1. Backlit Flex should be of LG Hi-Flex. 2. Writing work etc. should be digitally printed. Printing details will be provided by the department. (d) Installation: 1 No separate installation charge will be given. Note: Taking down of old Sign boards of any descriptionand any size to be deemed in the quoted rate.
3M&L for manufacture, supply and installation ofthe Back lit Glow sign board as per following Specifications:-: (a) Box: 1 The box size is approx10 feet x 2.5 feet. 2 The board frame should be made of MS Pipe 25x25x1.5 mm painted with one coat red oxide primer and 2 coat synthetic enamel paint. 3 Top, Bottom and Side cover shall be made of 26 SWG GI sheet with powder coating and Back side of the board shall be covered with 26 SWG plain GI sheet fixed with rivet and screws. (b) Lighting/Illumination: 1. Minimum one LEDtube light set is to be provided per five Square feet of board area. 2. Complete tube light set is to be provided. Tube lights shall be of reputed make. 3. Only copper wiring will be used. (c)Flex: 1. Backlit Flex should be of LG Hi-Flex. 2. Writing work etc. should be digitally printed. Printing details will be provided by the department. (d) Installation: 1 No separate installation charge will be given. Glow Sign Boards are required to be installed at main entrance gate of Pump House No 02 & Pump House No 03, Mechanical Laundry , 154 GH DG set , Pump House No -04 & 05 DG set roomon the entrance gate. 2 Installation shall be done using MS Fabrication (Brackets, Flats etc.) and required PCC work. Note: Taking down of old Sign boards of any descriptionand any size to be deemed in the quoted rate.
4M&L for manufacture, supply and installation of Sign Boards, single sided of hardened ACP sheet 3 mm thick , PoP riveted to stainless steel square pipe 20 mm x 20 mm and overall size of frame 900x1100 mm frame supported with another Frame made of 40 x 40 mm SS square pipe and 2.5 M long double legged stainless steel pipe 50 mm dia, thickness not less than 1.6mm(SS - 304 Grade) and fixed with each other with SS clamps.The board is fully reflectorised with high intensity grade retro reflective tape of any colour grade IV as per ASTM - D 4956-07 and lettering (any Nos) loc map white colour or as directed duly computerised cut including arrow, signs, logos etcfixed over retro reflective tape.Board to be fixed on ground 450 mm deep with necessary cement concrete including dismantling of old board complete all as specified and as directed. Note: The frame shape and size are to be made as per sample kept in AGE(I) Zakhama Office Make:JINDAL/TATA
5S&F energy saving high power LED Street light fitings for MES installation perimetr lightingcompleteof60 W made up of pressure die cast aluminum housing with embeded PC cover having TOP Opening separate driver compartment with IP66 Protection including GI Pipe bracket made out of 40mm dia light grade pipe of length 1.2 Mtrs, bend to shape 120-130 degree and MS clamps made out of 25x3mm flat iron 2 Nos including nut and bolts for fixing the bracket and making connections in flexible counduitand including taking out the existing fittings complete all as directed.
6S&F 1100 volts grade heavy duty flat cable ofsize 1.5 Sqmm 2 core, PVC insulated unsheathed/sheathed cable with aluminium conductor in service connectionsincluding taking down old cable of any descrip[tion complete all as specified and as directed.
7M&L for complete servicing of split type air conditioner 1.5/2.0 Ton capacity in situ or workshop as required after removing electric wire connection & cleaning of cooling coil, filter, etc. fixing in original or another location at Zakhama /Chakbama military station including testing to cooling complete to entire satisfaction of Engineer-in-Charge. Note : (a)New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Parts/ petty stores such as insulation tape, screws, small pieces of wires, plug top etc shall be included in quoted rate.
8Supply only starting capacitor 80-120 MFD for window type/split type air conditioner 1.5/2.0 Ton capacity complete all as specified and as directed
9Supply onlyrunning capacitor, paper impregnated di-electrictype of capacity 36-45 mfd AC 240 volt complete all as specified and as directed .
10Supply only control circuit (PCB) with remote device suitable for 1.5/2.0 Ton Split type AC complete all as specified and as directed.
11Supply only Remote universal type forSplit AC complete all as specified and as directed.
12Supply only Blower motor(Hot & Cold type)suitable for 1.5/2.0 Split type AC complete all as specified and as directed.
13Supply only swingmotor suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and as directed .
14Supply only over load relay suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and as directed.
15Supply only filter suitable for 1.5/2.0 Ton Split type AC complete all as specified and as directed.
16Supply onlyCondenser motor with fan blade suitable for 1.5 Ton capacity Split type AC complete all as specified and as directed.
17Supply only Thermostat switch with knob suitable for AC of any capacity complete all as specified and as directed.
18S&F in repair copper tube of size 1/4"" dia for connection of indoor and outdoor unit of split AC all as specified and as directed .
19Supply only insulation coverof size 1/4",3/8", 5/8"for insulating copper tube of split type AC all as specified and as directed
20S&F in repairs, sealed compressorincluding sealing of the compressor with welding after assembling for 1.5 Ton Capacity Spilit type AC/ Window type AC complete all as specified and as directed.
21Dismantling of unserviceable fan motor from the Air conditioner of 1.5 Ton capacity and re-winding of fan motor with existing gauge of super enameled copper conductor to match with the existing designincluding heat varnishing, overhauling, testing and re-fixing complete all as specified and as directed.
22M&Lfor testing leakage in system Split type Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vacuumizing the system complete all as specified and as directed.
23All as per item No 22 here-in-beforebut Split type Air conditioner of 2.0 ton capacitycomplete all as specified and as directed.
24Supply and charging ofcompressor oil Make: Freezol/bajaj (Capila-D)
25Dismantling of Refrigerator of any capacity and make from its existinglocation by disconnecting and sealing all electrical lines, maintenance/servicing/ overhauling includingreplacement of unserviceable parts,cleaning , taking out sludge from inner parts and washing with cleaning solution and refixing the same in its original location /position , connecting all electricalconnection and testing complete all as specified and as directed. Note : (a)New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Part if any, not mentioned in the schedule but required for smooth functioning of Refrigerator are deemed to be included in the unit rate of the item.
26Supply only Magnetic door gasket suitable for 165to200 ltrs capacity Refrigerator complete all as specified and as directed.
27Supply only magnetic door gasket suitable for 255 to310 ltrs capacity Refrigerator complete all as specified and as directed.
28Supply only Freezer / Evaporator suitable for165 to 200 ltrs capacity Refrigerator complete all as specified and as directed.
29Supply only Freezer/ Evaporator suitable for255 to 320 ltrs capacity Refrigerator complete all as specified and as directed.
30Supply onlythermostat switch to match with the existing item suitable for refrigerator of any capacity complete all as specified and as directed.
31Supply onlyopen type relay as per existing oneupto 310 Ltr capacity refrigerator complete all as specified and as directed.
32Supply only Air Filter suitable for for any make and any capacity Refrigerator complete all as specified and as directed.
33Supply only Capillary tube of suitable length as per existing size for refrigerator any make and any capacity complete all as specified and as directed.
34Supply onlyVegetable tray sample as per manufacture and suitable for refrigerator any type and any make complete all as specified and as directed.
35PVC Stand for Refigerator capacity upto 310 litercomplete all as specified and as directed.
36S&F in repairs, sealed compressor for 165 to 200 Liters refrigerator, hermetically type suitable for R-134 A refrigerant including sealing of the compressorwith welding after assembling complete all as specified and as directed.
37S&F in repairs, sealed compressor for 210 to 310 Liters refrigerator, hermetically type suitable for R-134 A refrigerant including sealing of the compressorwith welding after assembling complete all as specified and as directed.
38Dismantling of Deep freezer ofcapacity upto 425 literand make from its existinglocation by disconnecting and sealing all electrical lines, maintenance/servicing/ overhauling includingreplacement of unserviceable parts,cleaning , taking out sludge from inner parts and washing with cleaning solution and refixing the same in its original location /position , connecting all electricalconnection and testing complete all as specified and as directed. Note : (a)New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Part if any, not mentioned in the schedule but required for smooth functioning of Refrigerator are deemed to be included in the unit rate of the item.
39Supply onlyopen type relay as per existing oneupto 310 Liter capacity Deep freezer complete all as specified and as directed.
40Supply onlyopen type relay as per existing one320 to 425 Liter capacity Deep freezer complete all as specified and as directed.
41Supply only over load protectorsuitable for Deep freezer to match with the existing design complete all as specified and as directed.
42Supply onlythermostat switch to match with the existing item suitable for Deep freezer of any capacity complete all as specified and as directed.
43Supply only Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complete complete all as specified and as directed.
44Supply only Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity complete all as specified and as directed.
45Supply only Condenser motor (Rotary fan) suitable for any type and any capacity deep freezercomplete all as specified and as directed.
46S&F in repairs, sealed compressor for 400 Liters Deep freezer, including sealing of the compressorwith welding after assembling complete all as specified and as directed.
47Taking down voltage stablizer and removing of burnt coil winding with new super enameled copper winding as per existing gauge including varnishing drying alongwith replacement of unserviceable minor spares parts of capacity1 KVA complete all as speciied and asdirected.
48Taking down voltage stablizer and removing of burnt coil winding with new super enameled copper winding as per existing gauge including varnishing drying alongwith replacement of unserviceable minor spares parts of capacity2 KVA complete all as speciied and asdirected..
49Taking down voltage stablizer and removing of burnt coil winding with new super enameled copper winding as per existing gauge including varnishing drying alongwith replacement of unserviceable minor spares parts of capacity05 KVA complete all as speciied and asdirected.
50S&F in repairs, Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type& designed for input variation between 170 Vto 250 V with output voltage stabilized at 230 Vwith accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and directed. Make-Vertex/V-Gaurd/Volina.
51All as item No. 50 here in before but 4/5 KVA Capacity Make:Vertex/V-Gaurd/Volin/VENUS etc
52Supply onlyPVC insulated and PVC over all covered cord cable copper conductor 3 core of size 4 Sqmm complete all as specified and as directed.
53Supply and charging Refrigerant gas R-22 as existingAir Conditioner and refrigerator any type and any capacity complete all as speciied and asdirected.
54Supply and charging Refrigerant gas R-410A as exhisting Split/ window type Air Conditioner any type and any capacity complete complete all as speciied and asdirected.
55Supply and chargingRefrigerant gas R-134(a) in AC,refrigerator and deep freezer of any capacity complete complete all as speciied and asdirected.
56M&L for removing unserviceable geyser 25/50 ltr capacity from any position after disconnecting the inlet and outlet connection transporting to reputed work shop and servicing the geyser by descaling, Soldering & brazing, replace the unserviceable items like rusted nut-bolts, screws, washers, rubber gaskets, fusible plug, neon indication lamps red & green, changing unserviceable heating element, thermostat, geyser base plate assembly, hot & cold PVC connections 450mm long etc and refixing the same with necessary nut, bolt, washers and making connection of inlet and outlet pipe and testing for smooth functioning after complete installation complete complete all as speciied and asdirected. (Note :Soldering & brazing, replacement of Indicating lamps, Heating element, thermostat, Hot & Cold PVC will measured and paid separately under relevant items as supply only.)
57Supply only auto cut thermostat of any type suitable for 25/50 Liter capacity Geyser complete complete all as speciied and asdirected. (Make- Venus/Bajaj/Racold/Remson)
58Supply only heating element of 1.5 KW/ 2KW (Round or Triangular Head as required at site) including rubber washer (ISI marked) etc complete complete all as speciied and asdirected.
59Supply only indicator lamp (Red/ green) of any shape/ size as per existing pattern suitable for geysers of any capacity complete complete all as speciied and asdirected.
60Supply only PVC steel braided inlet & outlet connection pipe, 15 mm bore, 450 mm long with chromium plated check nuts & washers complete all as speciied and asdirected.
61S&F in repairs, Single pole and neutral enclosure with a two pin and earth plug and socket including one single pole MCB 20 Amps , 240 V complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail