Tender For Assembly For Reflection And Transmission Measurements Of Ceramics In Visible-Infrared Spectral Region
Tender Overview
Project Description
Assembly For Reflection And Transmission Measurements Of Ceramics In Visible-Infrared Spectral Region Supply, Installation And Warranty Of Assembly For Reflection And Transmission Measurements Of Ceramics In Visible-Infrared Spectral Region , “Assembly For Reflection And Transmission Measurements Of Ceramics In Visible-Infrared Spectral Region” The System Should Be Standalone Compact System To Measure Transmission And Reflection Of Visible-Infrared Radiation Of Ceramics Pellets, Quantitative Estimation Of Attenuation. The System Should Have Appropriate Light Source, Detector, Optical Fibers, Sample Mount And Necessary Software For Data Recording And Analysis. 1 Light Source Tungsten Halogen Source, 360-2000 Nm Or Wider, 10, 000 Hrs Or More, 2800 K I. Wavelength Range: 360Nm - 2.4?M Or Greater Ii. Source: Long Lifetime Tungsten Halogen Iii. Nominal Bulb Power: 4.75 W Or Higher Iv. Typical Output Power: 4.7 Mw Or Higher V. Shutter: No Vi. Fiber Connector: Sma 905 Vii. Integrated Cuvette Holder: No Viii. Power Requirements: 12 Vdc 2 Detector Wavelength Range: 350Nm - 1?M Or More. Optical Resolution: 1.34 Nm Fwhm ( Typical ) Integration Time: 3.8Ms - 10S Dark Noise: 50 Rms Counts Dynamic Range: 1300:1 For A Single Acquisition 8.5 X 10^7 ( System ) Signal To Noise Ratio: 300:1 ( Full Signal ) Detector Pixels:3648 Or More Detector: Linear Silicon Ccd Array Entrance Slit: 25 ?M Detector Collection Lens: No Electronics: A / D Resolution:16 Bit Or More Connectors: Usb High Density 40 Pin Jae Dd4 Connector Inputs / Outputs: 8 X User Programmable Gpios Trigger Modes: 4 Modes Or More Power Consumption: 250 Ma @ 5 Vdc Physical Dimensions: 89.1 Mm X 63.3 Mm X 35 Mm Or Smaller Weight: < 300 G 3 Probe For Reflection Geometry I. Wavelength Range: 400Nm - 2.1?M Or Greater Ii. Fiber Core Size: 200 ?M Or Greater Iii. Length: 2 M Or Longer Iv. Jacket: Silicone-Coated Steel Monocoil V. Probe Ferrule Diameter: 6.35 Mm ( 1 / 4? ) Or Larger Visible-Nir Reflection / Backscatter Probe 4 Probe For Transmission Measurements Uv-Visible Fiber- 2 Nos I. Wavelength Range: 300Nm - 1.1?M Or Greater Ii. Fiber Core Size: 400 ?M Or Larger Iii. Length: 2 M Or Larger Jacket: Silicone-Coated Steel Monocoil Complete Details In Annexure.
BOQ
| Sl. No. | Item Description |
| 1 | “Assembly for Reflection and Transmission measurements of ceramics in Visible-Infrared spectral region”The system should be standalone compact system to measure transmission and reflection of Visible-Infrared radiation of ceramics pellets, quantitative estimation of attenuation. The system should have appropriate light source, detector, optical fibers, sample mount and necessary software for data recording and analysis. 1 Light Source Tungsten Halogen Source, 360-2000 nm or wider, 10,000 hrs or more, 2800 Ki. Wavelength Range: 360nm - 2.4µm or greaterii. Source: Long Lifetime Tungsten Halogeniii. Nominal Bulb Power: 4.75 W or higheriv. Typical Output Power: 4.7 mW or higherv. Shutter: Novi. Fiber Connector: SMA 905vii. Integrated Cuvette Holder: Noviii. Power Requirements: 12 VDC2 Detector Wavelength Range: 350nm - 1µm or more.Optical Resolution: 1.34 nm FWHM (typical)Integration Time: 3.8ms - 10sDark Noise: 50 RMS countsDynamic Range: 1300:1 for a single acquisition8.5 x 10^7 (system)Signal to Noise Ratio: 300:1 (full signal)Detector Pixels:3648 or moreDetector: linear silicon CCD arrayEntrance slit: 25 µmDetector Collection Lens: NoElectronics: A/D Resolution:16 bit or moreConnectors: USB high density 40 pin JAE DD4 connectorInputs/Outputs: 8 x user programmable GPIOsTrigger Modes: 4 modes or morePower Consumption: 250 mA @ 5 VDCPhysical Dimensions: 89.1 mm x 63.3 mm x 35 mm or smallerWeight: < 300 g3 Probe for Reflection geometry i. Wavelength Range: 400nm - 2.1µm or greaterii. Fiber Core Size: 200 µm or greateriii. Length: 2 m or longeriv. Jacket: Silicone-coated steel monocoilv. Probe Ferrule Diameter: 6.35 mm (1/4?) or largerVisible-NIR Reflection/Backscatter Probe4 Probe for transmission measurements UV-Visible Fiber- 2 nosi. Wavelength Range: 300nm - 1.1µm or greaterii. Fiber Core Size: 400 µm or largeriii. Length: 2 m or largerJacket: Silicone-coated steel monocoilComplete details in annexure. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender