Tender For Maintenance Of Khadi Unit At Mathikunnu In Thrissur Distr
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Dec 2022
0 days left
EMD
17500
Bank guarantee accepted
Document Fee
1700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
thrissur → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Maintenance Of Khadi Unit At Mathikunnu In Thrissur Distr
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Dec-2022 | Da | Date | 28-Dec-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | APPENDIX-A |
| 2 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos sheet ( D S R2018, 15.28.2) |
| 3 | Providing non-asbestos high impact Polypropylene reinforced cement 6mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. (D S R12.8.) |
| 4 | Providing and fixing ridges and hips in non-asbestos fibre cement high impact polypropylene reinforced roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. Corrugated serrated adjustable ridges( D S R12.12.1) |
| 5 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes ( D S R10.16.1) |
| 6 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work ( D S R2018 , 13.52.1) |
| 7 | Providing Bitumin Compound covering to bolts and nuts in the existing Asbestos Roof with approved quality roofing compound for preventing the leak(od31082/2022_2023) |
| 8 | Engaging Labour forRepair / MaintenanceworksBeldar(D S R0115 ) |
| 9 | Engaging Labour forRepair / MaintenanceworksFitter(D S R0115 ) |
| 10 | Providingexisting Departmental non-asbestos high impact Polypropylene reinforced cement 6mm thick corrugated sheetsroofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain(andNew bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. (MODIFIEDD S R12.8.) |
| 11 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including Chowkhats, architrave, hold fasts etc complete and stacking within 50 metres leadOf area 3 sq. metres and below( D S R2018,15.12.1.) |
| 12 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - inCharge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)( D S R 2018 ,15.2 . 1) |
| 13 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar ( D S R2018 ,15.7.4 ) |
| 14 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.(D S R 2018,15.56 ) |
| 15 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.( D S R2016 2.31) |
| 16 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. ( D S R, 2.8.1) |
| 17 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.(D S R2016-2.25) |
| 18 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).( D S R 4.1.8.) |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).(D S R4.1.5) |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. ( 2018D S R,5.9.1. ) |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo - Mechanically Treated bars of Grade Fe 500 Dormore . ( 2018D S R,5.26) |
| 22 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:In cement mortar ( D S R2018,15.9.2) |
| 23 | DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site (OBSERVED DATA IRRIGATION60.7.1) |
| 24 | DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at site ( OBSERVED DATA IRRIGATION 60.7.8 ) |
| 25 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand). (2016 D S R 7.1.1. ) |
| 26 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 0.1 mm), with wall thickness 2.0mm (0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer\"s specification and direction of Engineer-in-charge Extruded section profile size 48x40 mm ( D S R9.117.1) |
| 27 | Providing and fixing to Door Frame 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mmwith inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x24 mm and 2 mm wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter). ( D S R9. 118. 1) |
| 28 | Cutting branches of trees overhanging above any structures of girth between 40cm to 60cm includingstacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges ofrope and pully etc without making any damages to nearby structures etc complete( OD5.2.33.5 ) |
| 29 | Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for FOUNDATIONANDPLINTH with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete(ObservedDataBuildings 50.6.2.2.) |
| 30 | Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete(ObservedDataBuildings 50.6.2.2.) |
| 31 | 12 mm cement plaster of mix : 1:4 (1 cement: 4coarse sand)(D S R201613.4.1.) |
| 32 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4coursesand). ( D S R14.1.2.) |
| 33 | Supplying at SiteR.C.C. Standards Fencing post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrigate 12,5 mm nominal size) ,IncludingProviding4 nos of 8 mmDiaTMTSteelReinforcement,with wooden plugs or 6 mm bar nibs wherever required as per the direction of the engineer in charge ( Cost of earth works in excavation, concrete work in foundation for fixing in position to be paid seperately. (D S R16.15.1) |
| 34 | Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only, provided with horizontal lines and two diagonels of barbed wire weighing 9.38 Kg per 100 metres ( Minimum ) , Between the two posts and fixed with G I staples on wooden plugs or GI binding wire tied to 6 mm bars nibs fixed whilecasting the posts ( Cost of RCC posts, struts, earth work and concrete to be paid for seperately ) Payment to bemade per metre cost of total length of barbed wire used. ( D S R2016 16.17.1) |
| 35 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigmentetc., complete. (DS R 2018,11.37 ) |
| 36 | Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete.(2018D S R ,8.31) |
| 37 | Providing and fixing false ceiling with e board classic tile or equivalent make of size 610x610x4 mm ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately) ( APPROVEDOBSERVED DATABUILDINGS50.12.5.1 ) |
| 38 | Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ). ( D S R21.5 ) |
| 39 | Engaging Labour For Maintenance works / Repair Works ELECTRITIAN |
| 40 | Engaging Labour ForRepair WorksCarpenter ( D S R 0112) |
| 41 | Engaging Labour For Maintenance works / Repair WorksPlumber |
| 42 | Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of thickness 4 mm (DSR14.6.1 ) |
| 43 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap.(D S R17.7.2 ) |
| 44 | Providing and fixing white vitreous china water closet squatting pan (Indian type) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (17.13.2 . ) |
| 45 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White( D S R17. 18.1 ) |
| 46 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.40 mm dia ( D S R17.28.2.2. ) |
| 47 | Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittingsarrangement of approved quality and colour. 600 mm long towel rail with total length of645mm, 78mm wide and effective height of 88 mm, weighing notless than 190 gms( D S R17.73.2) |
| 48 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore( D S R18.17.1 ) |
| 49 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore( D S R18.17.2 ) |
| 50 | Providing and fixing PTMT bib cock of approved quality and colour15 mm nominal bore, 122mm long, weighing not less than 99 gms( D S R18.54.2) |
| 51 | Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mmdiameter of the inner hinged round grating(D S R 18.58.2.1.) |
| 52 | Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms (D S R18.63) |
| 53 | Providing and fixing unplasticised P.V.C. connection pipe with PTMTNuts, collar and bush of approved quality and colour-15 mm nominal bore with 45 cm length ( D S R, 18.74.2.) |
| 54 | Cutting holes up to 30x30 cm in walls including making good thesame: With common burnt clay F.P.S. (non modular) bricks( D S R 2018, 18.76.1 ) |
| 55 | Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge( ODBUILDINGS50.17.1.1) |
| 56 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall( ObservedDataBuildings50.18.7.3.2.) |
| 57 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2(ObservedDataBuildings50.18.8.2.2.) |
| 58 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2( ODBuildings50.18.8.5.1) |
| 59 | Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2( Observed Data Buildings50.18.9.3.2.) |
| 60 | Providing and fixing PVC pipes includings joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia10Kgf/cm2 ( ODBUILDINGS50.18.9.4.1.) |
| 61 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2 ( ODBUILDINGS50.18.9.7.2) |
| 62 | Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2( OD50.18.9.9.2. ) |
| 63 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall( OD BUILDINGS 50.18.9.14.1.) |
| 64 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall( OD BUILDINGS50.18.9.17.2) |
| 65 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall( OD BUILDINGS 50.18.9.19.2) |
| 66 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow( OD50.18.9.20.1 ) |
| 67 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow ( OD50.18.9.20.2. ) |
| 68 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow( OD50.18.9.20.3 ) |
| 69 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee ( Observed Data Buildings50.18.9.20.5.) |
| 70 | ProvidingandfixingPVCmoulded fittings/accessoriesforRigidPVC pipes, including jointing with PVC solvent cement -63x63x63 mm dia Door Tee ( Observed DataBuildings50.18.9.20.6.) |
| 71 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl(ObservedDataBuildings50.18.9.20.7.) |
| 72 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow(ObservedDataBuildings50.18.9.22.1. ) |
| 73 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia45 \"Elbow(ObservedDataBuildings50.18.9.22.2. ) |
| 74 | Providing and fixingPVC moulded fittings /accessoriesforRigidPVC pipes ,including jointingwithPVC solvent cement-110 mmdiaDoorElbow (ObservedDataBuildings50.18.9.22.3.) |
| 75 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia tee(ObservedDataBuildings50.18.9.22.5.) |
| 76 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm diaDoorTee(ObservedData Buildings50.18.9.22.6) |
| 77 | Providing andfixingPVCmoulded fittings/accessoriesfor Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl( ObservedDataBuildings 50.18.9.22.8) |
| 78 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling( OD .50.18.9.22.11) |
| 79 | SupplyandFixingMirrorof GoodQuality ( 600 x 450 mm ) |
| 80 | Supply and Fixing P V C Floor Trap 110 mm with Necessary cutting of Concrete or Masonry and making Good the Same |
| 81 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.( 2018D S R ,13.61.1 . ) |
| 82 | Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. topslab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size), foundation concrete 1:5:10 (1cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar1:3 (1 cement : 3 coarse sand), finished smooth with a floating coatof neat cement on walls and bed concrete etc. complete as perstandard design: Inside dimensions 455x610 mm and 45 cm deep for singlepipe line :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5( D S R19.30.1.1.) |
| 83 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.( D S RELECTRICAL1.10.1) |
| 84 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 MM( DSRELECTRICAL 1.21.1) |
| 85 | Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)(DSRELECTRICAL1.43) |
| 86 | Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.(ODELECTRICALS90.4.2) |
| 87 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C( ODELECTRICAL 90.4.5.2.) |
| 88 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (D S RELECTRICAL1.25) |
| 89 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet(D S RELECTRICAL1.24.4) |
| 90 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch(D S RELECTRICAL1.24.1) |
| 91 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm(1.17.1) |
| 92 | Supply and fixing Batten LED 20 W 1200 MM WITH NECESSARY ACCESSORIES ETC |
| 93 | od31405/2022_2023 Engaging Labour for Repair works Electrician |
AI Tender Summary
Tender Timeline
Dec 21, 2022
11:30 IST
Tender Published
Tender notice published.
Completed
Dec 28, 2022
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedDec 28, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 30, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender