Supply Of Medical Equipment, bhilwara-Rajasthan

Medical Health And Family Welfare has published Supply Of Medical Equipment. Submission Date for this Tender is 27-12-2022. Electrocardiography Units Tenders in bhilwara Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

35183655
Supply Of Medical Equipment
Open Tender
Indian
Rajasthan
bhilwara
27-12-2022

Tender Details

Supply Of Medical Equipment- Intra Cranial Bleed Detector Specification : Dimension ( Cm ) -26X25x14 Weight ( Kg ) -1.1 Hemorrhage Detection- Subdural, Epidural, Intracerebral Hematoma Or Contusion Penetration Depth ( Mm ) – 30-35 Bleed Volume Detection - >2Ml Power System – Rechargeable Batteries Scan Modes Time – Quick Scan :20-30 Seconds, Full Head Scan :2-3 Min Alarm – Buzzer , Led Internal Memory – 16Gb ( Extendable ) Patient Data Backup- Cloud Storage ( Optional ) Accessory- Tablet, Chargers ( 2 ) , Disposable Caps , Ecg Machine 6 Channel Specification: Lead: Standard 12 Lead • Input Circuit: Floating: Built-In Defibrillator Protection • Acquisition Mode: Simultaneous 12 Leads Acquisition; • Measurement Range: + 5Mvpp; • Time Constant > 3.2S; • Frequency Response: 0.05Hz~150Hz ( -3Db ) ; • Sensitivity: 2.5Mm / Mv.5 Mm / Mv, 10Mm / Mv, 20Mm / Mv; • Input Impedance > 50Mq; • Input Circuit Current < 0.05A; • Noise Level < 15Uvp-P; • Anti-Baseline Drift: Automatic; • Patient Current Leakage < 10Ua ( 220V-240V ) ; • Power Supply: Ac: 100~24V, 50 / 60Hz, 30Va~100Va Dc: 14.8V / 2200Mah, Built-In Lithium Battery , Cbc Machine Specification: User-Friendly Interface Provide Various Anemia Indications Provide Text Of Alarm Information Automatic Blank Counting Automatically Start A Blank Counting And Auto-Assessment Of The Results During Start-Up Process Automatic Re-Counting Wider Linearity Range & Excellent Repeatability Maintenance-Free Syringe Built-In Patented Structure Thermal Printer. Easy To Load Paper And Fast Print Of Large Size Report State-Of-The-Art Technology Measuring Principles Impedance Methods For Cells Counting Cyanide Free Colorimetric Method For Hgb Measurement Measuring Channels - Double Channel For Counting Throughput From Beginning Of A Test To Completion Of The Printout: = 60 Seconds Counting Modes - Whole Blood, Pre-Diluted Blood Sample Volume Whole Blood: = 14 ?L Pre-Diluted Blood: = 20 ?L Parameters And Histograms 21 Parameters And 3 Histograms: Wbc, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, Rbc, Hgb, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Hct, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc, Wbc Histogram, Rbc Histogram, Plt Histogram Reference Value Settings Preset Five Sets Of Reference Values: Man, Woman, Child, Baby And General Alarm System Multiple Alarms Of Running Status Including Blank Counting Abnormal, Reagents Empty, Waste Full, Counting Hole Clogged, Counting Area Leak Or Bubble, Recorder Abnormal, External Printer Abnormal And Circuit Abnormal Etc Measures Of Unclogging Treatment Back Flushing, Soaking And Burning. Automatic Unclogging Treatment Before And After The Sample Analysis Printout English Print Report, Optional Report Formats Storage Can Store More Than 10, 000 Sample Results, Including Parameters, Histograms And Patient Information. Support Multiple Conditions Combination Query Communication Open Communication Protocol. Support Connection To Lis Data Import And Export Import Or Export Data Via Usb Port Quality Control System Include 9 Qc Files, Automatically Draw Quality Control Chart And Provide The Average, Sd, Cv Calibration System Support Manual And Automatic Calibration Software Upgrading Upgrading Software Via Usb Port Display And Touch Screen 10.4 Inch True Color Tft Lcd And Touch Screen Printer Built-In Patented Structure Thermal Printer, Paper 80Mm Wide, Easy To Load Paper. Report Printing Takes Only 5 Seconds Data Ports One Network Port, One Rs-232 Port, Four Usb Ports Optional External Devices With Usb Port Standard 101 Keyboards, Mouse, Barcode, Scanner And Multiple Printers Power - 220V, 50Hx Input : = 150Va Operating Environment Environment Temperature: 10°C ~ 30°C Relative Humidity: = 70% Atmospheric Pressure: 70.0Kpa ~ 106.0Kpa Dimensions -368Mm × 448Mm × 475Mm Weight - 23Kg , Semi Auto Analyzer Specification: Assay Types / Modesopen System / 8 Modes ( Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard , Two Point Non Linear, And Sample Blank Non Linear ) Range Of Absorbance0 - 3.0 Abs Resolution0.0001 Types Of Cuvettesi ) Quartz Flowcell Ii ) 10Mm Polystyrenecuvette Keyboardqwerty Keypad Storagei ) 200 Patient Reports Ii ) 300 Daily Qc Iii ) 3 Months Qc Data Air Purge Variable ( To Reduce Carry Over & Cross Contamination ) Rerunrerun For Endpoint & Absorbance Mode Recalibrationrecal For Kinetics Incubator4 Inbuilt Positions ( 370C ) Storagei ) 25, 600 Test Data Storage Ii ) 300 Daily Qc Iii ) 3 Months Qc Data Pc Softwarefor Interfacing With Pc / Laptop Assay Types / Modesopen System / 8 Modes ( Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard , Two Point Non Linear, And Sample Blank Non Linear ) Programmable Tests100 Sample Typeserum / Urine / Plasma / Body Fluids / Haemolysate Measurement Methodsmonochromatic And Bichromatic Photodiodesone Silicon Photodiode Wavelengths ( Filter Wheel ) 7 Filters ( 340, 405, 505, 546, 578, 620, 670 Nm ) And 1 Free Position Range Of Absorbance0 - 3.0 Abs Resolution0.0001 Stray Light= 2.3 Abs Delay / Incubation Time3-999 Seconds Read Time3-999 Seconds For End Point, 30-999 Seconds For Kinetic / Fixed Time Types Of Cuvettesi ) Quartz Flowcell Ii ) 6Mm Polystyrenecuvette Flowcell Volume32 ?L Displayhigh Resolution 240 X 128 Dots Graphical Lcd Withled Backlight Keyboardqwerty Keypad Printer In Built 384 Dots Thermal Printer Pc Communication9 Pin D Type Serial Connector Rs232 Port Pc Softwareavailable Memoryflash Storagei ) 25, 600 Test Data Storage Ii ) 300 Daily Qc Iii ) 3 Months Qc Data Result Reportscollated By Id, Date And Test Quality Controlsdaily And Monthly For 3 Levels With L Jplot Aspiration Volume200-1500 ?L Air Purge Variable ( To Reduce Carry Over & Cross Contamination ) Cross Contamination<1% Flow Cell Temperature250c, 300C, 370C; Peltier Control Incubator4 Inbuilt Positions ( 370C ) Light Source6v, 10W Quartz Halogen Lamp ( Life Span >3000 Hours ) Operating Voltage230vac ±10%, 50Hz, 50W Max Storage Temperature-10 To 40 0C Operating Temperature10 To 35 0C Humidity< / =80% Rh Dimensions250mm ( W ) X 290Mm ( D ) X 415Mm ( H ) Weight11 Kgs Language Supportedenglish

Key Value

Document Fees
INR 1000 /-
EMD
INR 480000.0 /-
Tender Value
INR 2.40 Crore /-

BOQ Items

Name of Work : ???? ?? ??????? ???????? ???????? ???? ?????? ????? ??????? ?????
Sl. No. Item Description
1Intra Cranial Bleed Detector Specification : Dimension (cm) -26X25X14 Weight ( KG) -1.1 Hemorrhage Detection- Subdural, Epidural, Intracerebral hematoma or contusion Penetration Depth ( MM) – 30-35 Bleed Volume detection - >2ml Power System – Rechargeable batteries Scan Modes time – Quick scan :20-30 Seconds, Full head scan :2-3 Min Alarm – Buzzer , LED Internal Memory – 16GB ( Extendable ) Patient data backup- Cloud Storage (Optional) Accessory- Tablet, Chargers(2), Disposable caps
2ECG Machine 6 Channel Specification: Lead: Standard 12 lead • Input Circuit: Floating: Built-in defibrillator protection • Acquisition Mode: Simultaneous 12 leads acquisition; • Measurement Range: + 5mVpp; • Time Constant > 3.2s; • Frequency Response: 0.05Hz~150Hz (-3dB); • Sensitivity: 2.5mm/mV.5 mm/mV, 10mm/mV,20mm/mV; • Input Impedance > 50MQ; • Input Circuit Current < 0.05A; • Noise Level < 15uVp-p; • Anti-baseline Drift: Automatic; • Patient Current Leakage < 10uA (220V-240V); • Power Supply: AC: 100~24V, 50/60Hz, 30VA~100VA DC: 14.8V/2200mAh, built-in lithium battery
3CBC Machine Specification: User-friendly interface Provide various anemia indications Provide text of alarm information Automatic blank counting Automatically start a blank counting and auto-assessment of the results during start-up process Automatic re-counting Wider linearity range & excellent repeatability Maintenance-free syringe Built-in patented structure thermal printer. Easy to load paper and fast print of large size report State-of-the-art technology Measuring Principles Impedance methods for cells counting Cyanide free colorimetric method for HGB measurement Measuring Channels - Double channel for counting Throughput From beginning of a test to completion of the printout: = 60 seconds Counting Modes - Whole blood, Pre-diluted Blood Sample Volume Whole Blood: = 14 µL Pre-diluted Blood: = 20 µL Parameters and Histograms 21 parameters and 3 histograms: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, MCV,MCH, MCHC, RDW-CV, RDW-SD, HCT, PLT, MPV, PDW, PCT, P-LCR, P-LCC, WBC Histogram, RBC Histogram, PLT Histogram Reference value settings Preset five sets of reference values: Man, Woman, Child, Baby and General Alarm System Multiple alarms of running status including blank counting abnormal, reagents empty, waste full, counting hole clogged, counting area leak or bubble, recorder abnormal, external printer abnormal and circuit abnormal etc Measures of Unclogging Treatment Back flushing, soaking and burning. Automatic unclogging treatment before and after the sample analysis Printout English print report, optional report formats Storage Can store more than 10,000 sample results, including parameters, histograms and patient information. Support multiple conditions combination query Communication Open communication protocol. Support connection to LIS Data import and export Import or export data via USB port Quality Control System Include 9 QC files, automatically draw quality control chart and provide the average, SD, CV Calibration System Support manual and automatic calibration Software Upgrading Upgrading software via USB port Display and Touch Screen 10.4 inch true color TFT LCD and touch screen Printer Built-in patented structure thermal printer, paper 80mm wide, easy to load paper. Report printing takes only 5 seconds Data Ports One network port, one RS-232 port, four USB ports Optional External Devices with USB port Standard 101 keyboards, mouse, barcode, scanner and multiple printers Power - 220V, 50Hx input : = 150VA Operating Environment Environment temperature: 10°C ~ 30°C Relative humidity: = 70% Atmospheric pressure: 70.0kPa ~ 106.0kPa Dimensions -368mm × 448mm × 475mm Weight - 23kg
4Semi Auto Analyzer Specification: Assay Types / ModesOpen system / 8 modes (Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard , Two point Non Linear, and Sample Blank Non Linear) Range of Absorbance0 - 3.0 Abs Resolution0.0001 Types of Cuvettesi) Quartz Flowcell ii)10mm PolystyreneCuvette KeyboardQWERTY Keypad Storagei)200 Patient Reports ii)300 Daily QC iii)3 Months QC Data Air Purge Variable (To reduce Carry over & Cross contamination) RerunRerun for Endpoint & Absorbance mode RecalibrationRecal for kinetics Incubator4 Inbuilt Positions (370C) Storagei) 25,600 test data storage ii) 300 Daily QC iii) 3 Months QC Data PC SoftwareFor interfacing with PC / Laptop Assay Types / ModesOpen system / 8 modes (Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard , Two point Non Linear, and Sample Blank Non Linear) Programmable Tests100 Sample TypeSerum / Urine / Plasma / Body Fluids / Haemolysate Measurement MethodsMonochromatic and Bichromatic PhotodiodesOne Silicon Photodiode Wavelengths (Filter wheel)7 Filters (340, 405, 505, 546, 578, 620, 670 nm) and 1 Free position Range of Absorbance0 - 3.0 Abs Resolution0.0001 Stray light= 2.3 Abs Delay / Incubation Time3-999 seconds Read Time3-999 seconds for End Point, 30-999 seconds for Kinetic / Fixed Time Types of Cuvettesi) Quartz Flowcell ii) 6mm PolystyreneCuvette Flowcell Volume32 µl DisplayHigh Resolution 240 x 128 dots graphical LCD withLED backlight KeyboardQWERTY Keypad Printer In built 384 dots Thermal Printer PC Communication9 pin D type Serial Connector RS232 Port PC SoftwareAvailable MemoryFLASH Storagei) 25,600 test data storage ii) 300 Daily QC iii) 3 Months QC Data Result ReportsCollated by ID, Date and Test Quality ControlsDaily and Monthly for 3 levels with L JPlot Aspiration Volume200-1500 µl Air Purge Variable (To reduce Carry over & Cross contamination) Cross Contamination<1% Flow Cell Temperature250C, 300C, 370C; Peltier control Incubator4 Inbuilt Positions (370C) Light Source6V, 10W Quartz Halogen Lamp ( Life Span >3000 Hours) Operating Voltage230VAC ±10%, 50Hz, 50W max Storage Temperature-10 to 40 0C Operating Temperature10 to 35 0C Humidity