Tender For Repair And Maintenance Of Various Items Installed At Maha Adhivakta Building, Prayagraj. Part J-Amc Of Networking Items, prayagraj-Uttar Pradesh

Public Works Department-PWD has published Tender For Repair And Maintenance Of Various Items Installed At Maha Adhivakta Building, Prayagraj. Part J-Amc Of Networking Items. Submission Date for this Tender is 13-12-2022. UPS Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35176150
Tender For Repair And Maintenance Of Various Items Installed At Maha Adhivakta Building, Prayagraj. Part J-Amc Of Networking Items
Open Tender
Indian
Uttar Pradesh
prayagraj
13-12-2022

Tender Details

Repair And Maintenance Of Various Items Installed At Maha Adhivakta Building, Prayagraj. Part J-Amc Of Networking Items-12 Data Switches 13 Core Switch- Minimum Of 24 Ports Of Rj-45 10 / 100 / 1000 Poe Ports, 24 Ports Of Sfp Gig, With Future Support Up To 8X10g Ports , All Gbic And Switch Should Be From The Same Oem, Hardware Andsoftware Configuration Support For Ipv6, Each Switch Should Support 384 Gbps Or More With Non Blocking Architecture. 14 Access Switch ( 48 ) Poe 10 / 100 / 1000 Rj45 Ports, ( 4 ) Combo Sfp Ports, ( 2 ) Dedicated Stacking Ports And External Rps Connector. 15 48-Port Category 6 Patch Panel, T568a / B Wiring, 1.75-High 16 1 Gb, 1000Base-Sx, Ieee 802.3 Mm, 850 Nm Short Wave Length, 220 / 550 M, Lc Sfp 17 Access Points- Dual Radio 802.11A / B / G / N Indoor Access Point With Internal Dual-Band Antenna. 18 Voice Communication 19 Pbx Ip Ready Communication Platform Pcm / Tdm, Isdn Bri, Pri System, 24 Ip Users , 16Trunk Line , 200 Digital Extension 16 Analog Extensionas Per Specifications With 24 Port Voice Mail System With Inbuilt 16 Party Meet Me Conference System, 500 Mail Boxes And 100 Hrs Pf Storage Capacity. Vm Should Be Of The Same Make As That Of Ip Pbx. 20 Dect Base Station For Cordless Solution 21 Dect Hand Setwith Charging Unit ( Cordless ) 22 Operator Console With Blf Hands Free, 26 Freely Programmable Keys With Red Led, Key Labeling With Paper Strip, Control Key With + / -, 3Navigation Keys Wall Mountable- As Per Specifications. 23 Ip Phone As Per Specifications For Senior People. 24 Digital Phone. 25 Clip Phone : Caller Id, Mute Key, Hands-Free Talking / Open Listening, On-Hook Dialing, Call Duration Display, Hearing Aid Compatible, Clip Call List, One-Touch Callback From Call List, Last 5 Numbers Redial, 10 Repertory Keys, Three-Tone With Adjustable Volume, Tone Sequence Frequency, 10 Ringer Melodies, Visual Ringer Indication, Real Time Indication, Recall Key 26 Pc For Administration 4 Gb Ram, 500 Gb Hard Disk, Dvd Drive, Mouse , Key Board, 17 Tft Monitor. 27 Ups 2 Kva With 4 Hrs Backup ( With New Battery ) Warranty As Per Manufacturer. 28 Copper / Fiber Cables And Connector 29 1- Category 6, 4-Pair, 23 Awg Solid Unscreened ( Utp ) Cable, Cmr ( Pvc ) , Gray ( 305 Mtr. Box ) ; 2- Category 6 Channel-Level Patch Cords W / Snag-Proof Boots, 3 Ft; 3- Category 6 Channel-Level Patch Cords W / Snag-Proof Boots, 7 Ft; 4-Cat 6 I / O Complete;5-Telephone Cable 50 Pair; 6- 6 Core Multimode Un Armored Cable; 7- 12 Port Liu 1 Urack Mount With All Accessories Includingadaptor Plate, Connectors, Pigtails Etc.; 8- 12-Fiber ( 6-Duplex ) Lc Mm Adapter Plate, Beige Adapters; 9- Splice Tray.; 10- Fiber Patch Cord Single Mode Lc To Lc Duplex 3 Mtr.; 11- Rack 600W / Al / 42U / 1000, H / D 60*50 A / U Extrusionswith 80Mmh Strong Steel Endframe Embedded At Top And Bottomwith Cable Entry Fromtop And Bottom Panel , Provision 19 Mtg Angles With UniqueU Marking. Total Modular Structure With Accessories; 12- 600Mm W X 500Mm 9 U In Height Closed Rack With Necessary Accessories. ( Fan 1Nos, Cantilever Shelf 1Nos, Pdu 6Pointx5amp 1Nos, H / W 10 Nos ) ; 13- Mdf 400 Pair 30 Man Power

Key Value

Document Fees
INR 854 /-
EMD
INR 216200.0 /-
Tender Value
INR 21.61 Lakhs /-

BOQ Items

Name of Work : - Repair and Maintenance of various items installed at Maha Adhivakta building, Prayagraj.(PART J-AMC of Networking Items)
Sl. No. Item Description
1This AMC contract covers maintenance and repair of components, which may be necessary as a result of normal wear and tear, except due to External damage, Natural Calamity, Burnt cases, etc. during the approved period.
21. This contract shall remain in force for a period of one year with effective date of AMC. (2) This contract will be deemed to be valid only if the system is in working order at the time of receiving the contract i.e. before the expiry of the warranty period / service contract. In case the service contract is sent after the expiry of the warranty period/service contract, it will be accepted, subject to checking of your system that it is in working order
33. Free service calls by the engineers will be made during the contracted period for any trouble with in the system. Each visit will be made within reasonable time from receipt of customer call, normally during working hours of the service department. No calls will be attended on Sundays or other holiday without pre-information. Complaint received in the morning will be attended on the same day normally and complaints received in the evening will be attended on next day, depending upon the availability of Service Engineers.
44) Arrangement to bring the system or any instrument to the customer care center will be made by the company if it is found necessary to do so. If any parts of the system are not available, the company shall not be liable for damages or incidentals arising out of delays in completing the job and the repairs will be undertaken as and when such parts are available. All efforts will however be made to complete the job as expeditiously as possible.
55. Firm shall also not be liable for any loss or damage arising out of fire, electric short circuit because of high voltages (above 250 volts), rodents damaging cord/ cables, accidental handling of system, seepage of water or other liquid or any natural calamity. (6) The system shall be provided with conditioned power supply with proper earthing etc. Any defect in the electrical installation independent of the system of wiring, fluctuation of power supply shall be attended/ rectified by you and are not our responsibility nor are they covered by this contract.
67. During the period of this contract you will not allow any unauthorized person to handle the equipment in order to rectify any defect however minor. It is in your own interest that any unauthorized person shifts no extension even in your own premises. (8) The Contract will cover maintenance of components, which may be necessary as a result of normal wear & tear during the period of contract except due to external damage, natural calamity, burnt cases, etc. Consumable like cables & batteries etc will be charged separately.
79. The service contract is offered for the original site of installation only. In case system is required to be reinstalled/ shifted with our approval, the service contract will continue but reinstallation charges will be extra. In the event of the customer deciding to withdraw from the service contract before the completion of the contract period there would be no refund of any amount for the unexpired period. (10) This contract is not transferable. In the event the customer transfers or sell the system, the contract will become null and void without refund being payable for the unexpired period.
811. Renewal of the service contract after its expiry will be at mutual discretion. (12) The service engineer will carry a identity card whenever he visits for preventive maintenance / service. (13) The customer will take care of the equipment, will house it in suitable condition and will follow such instructions on these matters and observe operating instructions.
913. The customer will take care of the equipment, will house it in suitable condition and will follow such instructions on these matters and observe operating instructions. 15. The Annual Maintenance charges shall be paid by the customer in full along with the signed agreement in advance.
1016. As agreed the service executive will be attending to the system once in every quarter for preventive maintenance.
1117. Under the rate of AMC charges high value item should not replace (Like Item No. 1& 6) if not in repairing condition.
12DATA SWITCHES
13Core Switch- Minimum of 24 ports of RJ-45 10/100/1000 PoE Ports, 24 ports of SFP Gig, with future support up to 8x10G ports ,All GBIC and switch should be from the same OEM, Hardware andsoftware configuration support for IPv6, Each switch should support 384 GBps or more with non blocking architecture.
14Access Switch (48) POE 10/100/1000 RJ45 ports, (4) combo SFP ports, (2) dedicated stacking ports and external RPS connector.
1548-Port Category 6 Patch Panel, T568A/B Wiring, 1.75"-High
161 Gb, 1000Base-SX, IEEE 802.3 MM, 850 nm Short Wave Length, 220/550 M, LC SFP
17Access Points- Dual Radio 802.11a/b/g/n indoor access point with internal dual-band antenna.
18VOICE COMMUNICATION
19PBX IP Ready Communication Platform PCM/TDM, ISDN BRI, PRI System, 24 IP users , 16Trunk Line , 200 Digital Extension 16 Analog Extensionas per specifications With 24 port voice mail system with inbuilt 16 party meet me conference system, 500 mail boxes and 100 hrs pf storage capacity. VM should be of the same make as that of IP PBX.
20DECT Base Station for Cordless Solution
21DECT Hand setwith charging unit (Cordless)
22Operator Console with BLF Hands free, 26 freely programmable Keys with red LED, Key Labeling with Paper strip, control key with + /-, 3navigation keys wall mountable- as per Specifications.
23IP Phone as per specifications for senior people.
24Digital Phone.
25Clip Phone : Caller ID, Mute key, Hands-free talking/ Open listening, On-hook dialing, Call duration display, Hearing aid compatible, CLIP call list, one-touch callback from call list, Last 5 numbers redial, 10 repertory keys, Three-tone with adjustable volume, tone sequence frequency, 10 ringer melodies, Visual ringer indication, Real time indication, Recall key
26PC for administration 4 GB RAM, 500 GB Hard Disk, DVD drive, Mouse ,Key Board, 17" TFT Monitor.
27UPS 2 KVA with 4 hrs backup (with new battery) warranty as per manufacturer.
28Copper/Fiber Cables And Connector
291- Category 6, 4-Pair, 23 AWG Solid Unscreened (UTP) Cable, CMR (PVC), Gray (305 Mtr. Box); 2- Category 6 Channel-Level Patch Cords w/Snag-Proof Boots, 3 ft; 3- Category 6 Channel-Level Patch Cords w/Snag-Proof Boots, 7 ft; 4-CAT 6 I/O Complete;5-Telephone cable 50 Pair; 6- 6 core multimode un armored cable; 7- 12 port LIU 1 Urack mount with all accessories includingadaptor plate, Connectors, pigtails etc.; 8- 12-Fiber (6-Duplex) LC MM Adapter Plate, Beige Adapters; 9- Splice Tray.; 10- Fiber Patch Cord Single Mode LC to LC Duplex 3 Mtr.; 11- Rack 600W /AL/42U/1000, H/D 60*50 A/U extrusionswith 80MMH strong steel endframe embedded at top and bottomwith cable entry fromtop and bottom panel ,Provision 19" MTG angles with unique"U" marking. Total modular Structure with Accessories; 12- 600mm W x 500mm 9 U in height closed rack with necessary accessories. (FAN 1NOS, CANTILEVER SHELF 1NOS, PDU 6POINTX5AMP 1NOS, H/W 10 NOS); 13- MDF 400 Pair
30Man Power
31Onsite Resident Engineer for one year
32One Technician for one Year
33GST @ 12%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail