| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard / dense/any type of soil for laying of cables complete all as specified and directed by Engineer-in-Charge. |
| 2 | Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-Charge. |
| 3 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 4 | Material & Labourfor cutting of existing road / hard standing up to 15 cm depth and 30 cm width for laying of pipe lines / cables and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below hard standing will be measured and paid under relevant items. |
| 5 | Material & Labour for Power Cables, Aluminum Stranded Conductor 70 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings / connecting overhead lines with suitable binding wire and testing on completion including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge. (Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.) |
| 6 | All as per item No. 05.00 here-in-before but of size 50 sqmm, 3.5 core. |
| 7 | All as per item No. 05.00 here-in-before but of size 35 sqmm, 3.5 core. |
| 8 | All as per item No. 05.00 here-in-before but of size 25 sqmm, 4 core. |
| 9 | All as per item No. 05.00 here-in-before but of size 16 sqmm, 4 core. |
| 10 | All as per item No. 05.00 here-in-before but of size 16 sqmm, 2 core. |
| 11 | All as per item No. 05.00 here-in-before but of size 10 sqmm, 4 core. |
| 12 | All as per item No. 05.00 here-in-before but of size 10 sqmm, 2 core. |
| 13 | Supply and fix in replacement of 50mm dia bore tubes, \"light grade\" galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply and fix in replacement of MCCB 100A, 25KA, 4 Pole with fixed thermal magnetic release mounted in MCCB sheet steel enclosureincluding spreader terminals and connecting up with suitable lugs complete all as specified and directed by Engineer-in-Charge. Engineer-in-Charge. |
| 16 | Supply and fix in replacement of MCCB, 160 A, 3 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal magnetic release along with busbar spreader terminal plates including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and fix in replacement of MCCB, 250 A, 3 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal magnetic release along with busbar spreader terminal plates including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply and fix in replacement of 120 Watt LED street light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy =100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including taking down of existing unserviceable street light fitting of any description complete all as specified and directed by Engineer-in-Charge. |
| 19 | All as per item No. 18.00 here-in-before but of 90 Watt LED street light fitting. |
| 20 | All as per item No. 18.00 here-in-before but of 70 Watt LED street light fitting. |
| 21 | All as per item No. 18.00 here-in-before but of 60 Watt LED street light fitting. |
| 22 | All as per item No. 18.00 here-in-before but of 45 Watt LED street light fitting. |
| 23 | All as per item No. 18.00 here-in-before but of 35 Watt LED street light fitting. |
| 24 | Supply and fix Thermoplastic cable junction box IP 66/67 “weather proof”, for outdoor installation (with knockouts for cable entry) of size 220mm x 140mm x 95mm with provision of 63Amps rated four pole (3P+N) connector, one single pole MCB of 6 Amps rating mounted on DIN rail, stainless steel cable glands of suitable size for incoming and outgoing cables and PVC gland for copper control cable for light fitting including fixing on steel tubular poles / PCC poles with suitable size MS clamps with fixing brackets (02 Nos), nuts, bolts, washers etcduly painted with two coats of aluminium paint over a coat of red oxide primer on steel clamps and brackets etc complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply and connect in replacement of PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts grade, conforming to IS 694, three core, 2.5 sqmm for connecting from junction box to street light fitting/ connect in any description complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and connect in replacement of PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts grade, conforming to IS 694, three core, 1.5 sqmm for connecting from junction box to street light fitting complete all as specified and directed by Engineer-in-Charge. |
| 27 | Taking down the defective LED street light fitting/security light fitting of various wattage from 45 to 120 watt from 9m/11m pole etc from any position/height and indentifying the fault and replacing the defective LED driver/replacing the burnt wiring and re-assembling the fittings and re-fixing in its original position and testing for proper functioning complete all as directed by Engineer-in-Charge.Note :- Supply only of LED driver and supply and replacement of cable shall be measured and paid separately under relevant items of BoQ. |
| 28 | Supply and fixing in replacement of LED driver as per sample suitable for existing make & model of 120 watt LED street light fitting complete all as specified and as directed. |
| 29 | Supply and fixing in replacement of LED driver as per sample suitable for existing make & model of 90 watt LED street light fitting complete all as specified and as directed. |
| 30 | Supply and fixing in replacement of LED driver as per sample suitable for existing make & model of 70 watt LED street light fitting complete all as specified and as directed. |
| 31 | Supply and fixing in replacement of LED driver as per sample suitable for existing make & model of 45 watt LED street light fitting complete all as specified and as directed. |
| 32 | Supply and fix in replacement of LED Post top light fitting 40 Watt / 45 Watt, made in die-cast aluminum housing with decorative clear opal acrylic diffuser, IP 65 protection, spun aluminum powder coated canopy, low power Warm White (WW) LEDs connected in series and parallel combination with better heat dissipation arrangement with LED color temperature- 3000K ±300K, Highly efficient constant current electronic driver having operating voltage range from 140-280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 5KV complete suitable for up to 60mm OD pipe entry with fixing bolts including taking down existing unserviceable post top light of any description complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fix in replacement of GI pipe bracket made out of 40mm dia medium grade GI pipe of 1.50mtr long bent to required shape and fixed to steel tubular / PCC pole with clamps made out of 40mm x 5 mm MS flat fixed with suitable nuts, bolts and washers etc including taking down existing unserviceable bracket of any description complete all as specified and directed by Engineer-in-Charge. |
| 34 | Making holes (02 Nos - one near cable junction box and other near street light bracket) on existing steel tubular poles of any type, thickness & height through drilling / gas welding work having smooth and chamber edge of hole, for drawing street light control cable through inside of pole complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and fix in replacement of LED batten with CRCA sheet steel box type body pre-wired suitable for and including provision of 1x20Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 36 | Supply and fix in replacement ofintegrated LED batten 10 watt, 2 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted two core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 37 | Supply and fix in replacement ofintegrated LED batten 20 watt, 4 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 38 | Supply and fix LED 14W lamp, White colour, retrofit type, B-22 holder base with polycarbonate diffuser and aluminium heat sink, complete all as directed. |
| 39 | Supply and fix LED 9W lamp, White colour, retrofit type, B-22 holder base with polycarbonate diffuser and aluminium heat sink, complete all as directed. |
| 40 | Supply and fix in replacement of Post top lantern Black ABS plastic spigot, spun aluminium canopy, with clear acrylic diffuser and accessories along with LED lamp 14 Watt with B22 base lamp holder including taking down existing unserviceable post top lantern fitting of any description complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply and erection of Hot dip galvanized tapered octagonal pole of height 8.0 mtrs in single section having top dia 70mm and bottom dia 135mm made up of 3mm thick sheet and welded with a base plate of size 225mm x 225mm x 16mm thick and provided with 1000mm long one bracket as directed with 15 degree of angle for mounting street light fitting complete with provision of 04 Nos of ‘J’ type foundation bolts of size not less than 20mm dia, 700mm long embedded in PCC foundation concrete as per manufacturer’s recommendation including necessary earth work, RFR etc complete. A door should be provided at a height of 500mm from the base plate for accommodating and including provision of SPN aluminium bus bar system suitable for connecting 2/4 core, 16 sqmm aluminium cable and 01 No. of 16A SP MCB for street light protection inside the pole shaft. Radium reflector band / strips of 5cm wide in Red, Yellow & White colour shall be provided at a height of 1.25mtr from base plate. Numbering of pole shall be done in white colour on black background at suitable place on the pole complete all as directed by Engineer-in-Charge.Note :- (a) Excavation, earth work., and PCC foundation shall br deemed to be included in quoted rates.(b) PCC shall be of M-20 grade all as directed by Eng-in-Charge.(c) The rate includes dismantling of old and unserviceable PCC/Steel poles. |
| 42 | S&F of LED flood light luminaire of 90 Watt capacity, with toughened glass cover, IP 66 protection and individual high power LEDs with secondary optics having Lumen efficacy of LED =140 lm/W, viewing angle of 120° to ensure better uniformity, independent Potted IP67 electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection upto 10 kV with inbuilt SPD & other safety test as per IS 15885 Part-2 / Sec 13, IEC60598-1 complying, duly fixed on High mast of any height and type, with and incl making all electric connection complete all as directed. |
| 43 | All as per item No. 42.00 here-in-before but of 150 Watt LED flood light fitting. |
| 44 | Supply and fix in replacement of MCB 40A, 10 KA, SPN, \"C\" curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 45 | Supply and fix in replacement of MCB 6 - 32A, 10 KA, single Pole, \"C\" curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 46 | Material and labour for preparation of old painted surfaces of HT / LTsteel poles and painting with one coat of aluminium paint on all steel surfaces such as poles, channels, angles, clamps, nuts, bolts and washers of any description and Zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band / strips (Make: 3M or equivalent) of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from coping of pole and writing the pole number in black colour on yellow background at a suitable place on the pole including applying one coat of cement based paint on PCC coping of pole complete all as specified and directed by Engineer-in-Charge. |
| 47 | M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I (2009) and testing on completion including taking out of unserviceable earthing set complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II |
| 48 | Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT baRs @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II |
| 49 | M&L for Cable jointing kit for 33 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 50 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95/120 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 51 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95/120 Sqmm complete all as specified and as directed by Engineer-in-Charge. |
| 52 | Unbinding from insulators and restretching ACSR conductor of any size on LT poles with and including binding with 2mm dia aluminium binding wire to insulators, complete all as specified & directed.Note : 1. The cost of binding wire is deemed to be included in quoted rates.2. The distance between two poles having 4/5/6 conductors will be considered as one span. |
| 53 | M & L for fabrication, supply, installation and testing in replacement of outdoor type cubicle panel board busbar box with MCCB suitable for 3 phase 4 wire, 50 Hz supply system factory fabricated made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front openable door with locking arrangement complete with powder coat painting and suitable packing material for IP-54 degree of protection and including provision of 40mmx40mmx5mm angle iron base frame of suitable size for mounting the panel board at a height of 450mm above GL and grouted in PCC foundation. The size of panel board shall not be less than 500mm x 500mm x 300mm (outer dimensions)for accommodating and including provision of following switchgears complete:- (i) TPN Aluminium bus bar of 25 x 5 mm provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators suitable for connecting 2 or 3 outgoing cables including provision suitable glands.(ii) MCCB, 63 Amps, 25 KA breaking capacity , 4 Pole, 415 V, 50 Hz, adjustable thermal and magnetic setting including spreader terminals - 01 No |
| 54 | M&L for pruning of tree branches up to 2.0 meter clearance all around HT/LT overhead lines and depositing where directed at a distance not less than 50m complete all as specified directed by Engineer-in-Charge. Note: The item will be measured in span length between poles. The approx span length is 50m. |
| 55 | Supply and fix in replacement of Stay assembly with 16mm dia stay rod and all accessories as shown in electrical plate No. 1 complete all as specified and directed by Engineer-in-Charge. Note: Loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) |
| 56 | Supply and fix in replacement of Galvanized stay strand, 7/3.15mm including proper tightening to required tension complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply and fix in replacement of Loop type insulator, vitreous porcelain, white, brown or green Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed by Engineer-in-Charge. |
| 58 | M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundations of pole/ stay assembly complete all as specified and directed by Engineer-in-Charge. |
| 59 | M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc complete all as specified and directed for the following points:-Note : 1. In case cutting & chasing of conduit is encountered with any beam / column/Stone wall, the ISI Marked PVC casing & capping or surface conduit will be used to avoid any damage to the RCC portion.2. No cutting & chasing shall be done on ceiling surface for laying PVC conduit for ceiling fan point wiring etc, hence the PVC casing & capping or surface conduit will be used for the same. 3. In place of terminal box on stone wall, PVC gang box/rectangular box for mounting switches/sockets/regulators with back and front cover will be used. |
| 60 | One light Point/Lamp Holder/ ceiling fan/ exhaust fan/call bell point controlled by one switch |
| 61 | One 6A socket point controlled by one switch on independent board |
| 62 | One 6A socket point controlled by one switch on same board |
| 63 | All as per item No. 59.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires. |
| 64 | All as per srl item no. 59.00 here-in-before but with 4 sq mmFRLS copper wire with 4 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board. |
| 65 | M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including taking down old sub main wiring complete all as specified and directed by Engineer-in-Charge for the following sizes:- Note: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length(ii) Five runs of copper cable and one run of PVC conduit shall be measured as one unit length(iii)In case cutting & chasing of conduit is encountered with any beam / column/Stone wall, the PVC casing & capping or surface conduit will be used to avoid any damage to the RCC portion as directed. |
| 66 | 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) |
| 67 | 2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) |
| 68 | 4runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) |
| 69 | Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed |
| 70 | Supply and fix in replacement of switch piano flush type 6 Amps, one way, 240V, 50Hz including taking down existing unserviceable switch of any description complete all as specified and directed. |
| 71 | Supply and fix in replacement of electronic fan regulator rotary type in 5 steps, 240V, 50Hz including taking down existing unserviceable fan regulator of any description complete all as specified and directed. |
| 72 | Supply and fix in replacement of bell push switch flush type 6 Amps, 240V, 50Hz including taking down existing unserviceable bell push of any description complete all as specified and directed. |
| 73 | Supply and fix in replacement of socket 6 Amps, 2-in-1 flush type universal 240V, 50Hz including taking down existing unserviceable socket of any description complete all as specified and directed. |
| 74 | Supply and fix in replacement of switch piano flush type 16 Amps, one way, 240V, 50Hz including taking down existing unserviceable switch of any description complete all as specified and directed. |
| 75 | Supply and fix in replacement of socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz including taking down existing unserviceable socket of any description complete all as specified and directed. |
| 76 | Supply and fix in replacement of ceiling rose 6 Amps, 3 plate, 240V, 50Hz including taking down existing unserviceable ceiling rose of any description complete all as specified and directed. |
| 77 | Supply and fix in replacement of Lamp holder, angle type with metal ring, PVC/Polycarbonate body including taking down existing unserviceable lamp holder of any description complete all as specified and directed. |
| 78 | Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. |
| 79 | Supply and fix in replacement of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCCB / MCBs shall be measured and paid separately. |
| 80 | Supply and fix in replacement of MCB distribution board, TPN, 4 way, 415 V, 3 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCBs shall be measured and paid separately. |
| 81 | All as per item No. 75 here-in-before but SPN, 12 way, 230 V, 1 phase, ACNote:MCBs shall be measured and paid separately. |
| 82 | All as per item No. 75 here-in-before but SPN, 8 way, 230 V, 1 phase, AC Note:MCBs shall be measured and paid separately. |
| 83 | All as per item No. 75 here-in-before but SPN, 4way, 230 V, 1 phase, AC Note:MCBs shall be measured and paid separately. |
| 84 | Supply and fix MCCB 100A, 16 KA, 3 Pole, 415 V, 50 Hz with fixed thermal magnetic release complete all as specified and directed. |
| 85 | Supply and fix MCB 100A, 10 KA, TPN, 415 V, 50 Hz complete all as specified and directed. |
| 86 | Supply and fix MCB 63A, 10 KA, TPN, 415 V, 50 Hz complete all as specified and directed. |
| 87 | Supply and fixMCB 40A, 10 KA, SPN, \"C\" curve, 240 V, 50 Hz complete all as specified and directed. |
| 88 | Supply and fix MCB 6 - 32A, 10 KA, single Pole, \"C\" curve, 240 V, 50 Hzcomplete all as specified and directed. |
| 89 | Supply and fix in replacement of call bell ding dong, AC, 240V, 50Hz including taking down existing unserviceable call bell of any description complete all as specified and directed. |
| 90 | Supply and fix in replacement ofintegrated LED batten 20 watt, 4 feet long, twin light (cool white & warm white) in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 91 | Supply and fix in replacement of LED bulkhead luminaire 10W in die-cast aluminium alloy/ PVC body heat resistant prismatic glass cover, with specially designed gasket for minimum IP 55 degree of protection complete all as specified and directed by Engineer-in-Charge. |
| 92 | Supply and fix in replacement of ventilating fan with plastic body with louvers, 250mm sweep, single phase, 230 volts, 50 Hz. including taking down existing unserviceable ventilating fan of any description complete all as specified and directed. |
| 93 | Supply and fix in replacement of Decorative wall light fixture made up of Polycarbonate with and including 7W retrofit LED lamp, full white/ Warm whiteof approved model including taking down existing unserviceable light fitting of any description complete all as specified and directed. |
| 94 | Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 9\" X 11\" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with brass/GI screws with washers complete all as specified and directed.Note: S&F of switches, sockets & regulators shall be measured and paid separately. |
| 95 | Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 8\" X 5\" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws with washers complete all as specified and directed. Note: S&F of switches, sockets & regulators shall be measured and paid separately. |
| 96 | Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 5\" X 5\" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws with washers complete all as specified and directed by Engineer-in-Charge. Note: S&F of switches, sockets & regulators shall be measured and paid separately. |
| 97 | Supply and fix in replacement of recessed mounted LED panel light 2\"x2\" size, 36 watts, full white / warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for Amstrong / grid false ceiling complete fix fixing accessories including taking down existing unserviceable light fitting of any description completeall as specified and directed. |
| 98 | Supply and fix in replacement of fan capacitor 2.5 mfd, 440V suitable for ceiling fan complete all as specified and directed by Engineer-in-Charge. |
| 99 | Taking down Ceiling fan of any size carefully, dismantling blades and Cutting and removing of old burnt/damaged winding, cleaning of slots and other parts and rewinding the ceiling fan motor with super enameled copper winding wire of existing gauge with suitable class of insulation, applying varnish, heating, drying, assembling, including replacement of bush/bearings, rubber seal, ms split pin, down rod, and testing for satisfactory performance and refixing after repair in its existing or new location and connecting up including provision of cable from ceiling rose or connector to ceiling fan and testing for satisfactory functioning complete all as specified and directed by Engineer-in-Charge. |
| 100 | All as per item No. 94.00 here-in-above but for exhaust fan/desert cooler motor of any size |
| 101 | Taking down carefully the electric storage type water heater of capacity up to 50 ltrs from its installed position by disconnecting all water and electric supply connections for necessary repairs, opening the geyser carefully, identifying and replacing the defective parts, reassembling and reinstalling in its existing location or new location and testing for proper functioning complete all as specified and directed by Engineer-in-Charge. Note: The spare parts required shall be measured and paid separately under relevant items as \"Supply Only\". |
| 102 | Supply only copper heating element 1500 Watts / 2000 Watts of any type suitable for existing model of geyser 25L/50L complete all as specified and directed by Engineer-in-Charge. |
| 103 | Supply only thermostat of any type suitable for existing model of geyser 25L/50L complete all as specified and directed by Engineer-in-Charge |
| 104 | Supply only apparatus plate of any type suitable for existing model of geyser of capacity 25L/50L complete all as specified and directed by Engineer-in-Charge. |
| 105 | Supply only indicator lamp Red or Green of any type suitable for existing model of geyser of capacity 25L/50L complete all as specified and directed by Engineer-in-Charge. |
| 106 | Supply and fix in replacement of flexible PVC connection 450mm long suitable for Hot/Cold water application complete all as specified and directed by Engineer-in-Charge. |
| 107 | M&L for Servicing of window type AC 1.5 / 2.0 TR capacity, any type/make, by carefully taking down from window / wall,removing power connection, front PVC grill, air filters and applying air blower to remove all dust, washing, cleaning, removing dirt, including cleaning and washing of cooling and condenser coil, re-assembling the dismantled components,refixing to its original position and testing for proper functioning complete all as specified and directed by Engineer-in-Charge. |
| 108 | M&L for servicing of split type AC of 1.5 / 2.0 TR capacity, any type/make, in situ at installed location, removing power connection, carefully opening the indoor and outdoor unit, removing filters, applying blower in both the units to remove all dust, cleaning, washing, removing dirt, including cleaning and washing of evaporator coil of indoor cooling unit and condenser coil of outdoor unit, re-assembling the dismantled components,refixing to its original position and testing for proper functioning complete all as specified and directed by Engineer-in-Charge. |
| 109 | Supply and fix in replacement of set of PVC filters suitable for window type AC / indoor unit of split type AC 1.5 Ton / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 110 | Supply and fix in replacement of following spare parts suitable for indoor unit of split type AC 1.5 Ton / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 111 | Blower bush |
| 112 | Blower fan blades |
| 113 | Blower motor |
| 114 | PCB |
| 115 | Display unit |
| 116 | Swing motor |
| 117 | Capacitor 1.0 mfd to 2.5 mfd suitable for blower motor |
| 118 | Supply and fix in replacement of suction / discharge valve, brass, of size 1/4\"\" to 3/4\"\" suitable for outdoor unit of split type AC 1.5 Ton / 2.0 TR capacity / suction / discharge valve of package type AC plant of existing model suitable for 5.5 TR / 11 TR capacity / walk-in-cooler of capacity 2.0 TR complete all as specified and directed and by Engineer-in-Charge. |
| 119 | Supply and fix in replacement of thermostat temperature sensor suitable for indoor unit of split type AC / window type AC 1.5 Ton / 2.0 TR capacity of existing model / package type AC plant of existing model suitable for 5.5 TR / 11 TR capacity / walk-in-cooler of capacity 2.0 TR complete all as specified and directed and by Engineer-in-Charge. |
| 120 | Supply and fix in replacement of PCB with display unit suitable for window type AC 1.5 TR / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 121 | Supply and fix in replacement of following spare parts suitable for window type / outdoor unit of split type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 122 | Hermetically sealed reciprocating type / rotary type compressor unit 1.5 TR capacity including gas charging complete |
| 123 | Hermetically sealed reciprocating type / rotary type compressor unit 2.0 TR capacity including gas charging complete |
| 124 | Running capacitor 35 mfd to 60 mfd |
| 125 | Fan motor, copper wound |
| 126 | Fan blades |
| 127 | Fan capacitor 4.0 mfd to 6.0 mfd |
| 128 | Supply and fix in replacement of copper condenser coil suitable for outdoor unit of 1.5 / 2.0 TR capacity split type / window type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 129 | Supply and fix in replacement of single phase contactor suitable for 1.5 / 2.0 TR capacity split type Air conditioners / Walk-in-cooler of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 130 | M&L for gas charging of Air Conditioner window / split type / walk-in-cooler of capacity 1.5 / 2.0 TR with R - 22 / R-32 /R-410a or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/brazing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge. |
| 131 | Supply and fix in replacement of copper tube of size 1/4\"\" to 1/2\"\" suitable for 1.5 / 2.0 TR capacity split type Air conditioners / walk-in-cooler / Central / package type AC of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 132 | Supply and fix in replacement of nitrile rubber foam insulation of size 1/4\"\" to 1/2\"\" suitable for 1.5 / 2.0 TR capacity split type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 133 | Supply and fix in replacement of PVC front grill suitable for 1.5 / 2.0 TR capacity window type Air conditioners of existing make / model complete all as specified and directed and by Engineer-in-Charge. |
| 134 | Supply and testing in replacement of remote control unit with batteries suitable for 1.5 / 2.0 TR capacity split type / window type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 135 | Supply and fix in replacement of heavy duty Mild Steel powder coated wall mount bracket with grouting bolts complete set suitable for wall mounting of outdoor unit of 1.5 / 2.0 TR capacity split type AC complete all as specified and directed by Engineer-in-Charge. |
| 136 | Supply and fix in replacement of PVC drain pipe 1/2\"\" size including proper clamping on wall surfaces suitable for 1.5 / 2.0 TR capacity split type AC complete all as specified and directed by Engineer-in-Charge. |
| 137 | Material and labour for shifting of Split type AC 1.5 / 2.0 TR capacity of any make / model from one location to the other location alongwith stabilizer by carefully taking down the indoor and outdoor unit, copper piping with insulation, drain pipe, wall mount bracket etc and installing the same at new location including testing & commissioning complete all as directed by Engineer-in-Charge. Note : 1. The cost of making hole for passing through inlet / outlet copper pipes, drain pipe and electrical cable and making good of surface at both location as original by plastering / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect.2. Extra copper piping if required at new location will be measured and paid separately under respective items. |
| 138 | Material and labour for shifting of window type AC of any type/make / model of 1.5 / 2.0 TR capacity alongwith stabilizer from one location to other location complete with and including making of suitable opening in wall or cutting and removing steel grill from existing window, with and including supply and fixing of new wooden frame / plywood of suitable size and thickness for proper fixing of outer chasis of AC at new location including painting with matching colour, making good of disturbed surface as original etc, including testing & commissioning, complete all as directed. Note : The cost of making suitable opening in brick wall or removing steel grill and/or glass pane from existing window and making good of surface at both location as original by brick work, plastering / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect. |
| 139 | Material and labour for gas charging of deep freezer of capacity up to 310 Liters with R - 22 / R-134A or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/bracing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge. |
| 140 | Supply and fix in replacement of following spare parts suitable for deep freezer of capacity up to 310 Liters of existing model complete all as specified and directed and by Engineer-in-Charge:- |
| 141 | Hermetically sealed reciprocating type / rotary type compressor unit including gas charging. |
| 142 | Compressor start relay. |
| 143 | Overload relay |
| 144 | Starting capacitor 40/60 mfd to 100/120 mfd |
| 145 | Running capacitor 10 mfd to 30 mfd |
| 146 | Copper condenser coil |
| 147 | Thermostat |
| 148 | Supply and fix in replacement of aluminium body shaded pole motor, 220/240V, 50-60Hz, 1300-1500 RPM of suitable rating for deep freezer of capacity up to 310 Liters / water cooler of capacity up to 150 liters capacity of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 149 | Supply and fix in replacement of 4\"\" x 4\"\" exhaust fan, 220/240V, 50Hz suitable for deep freezer / refrigerator of capacity up to 310 Liters of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 150 | Supply and fix in replacement of refrigerant filter drier suitable for deep freezer of capacity up to 310 Liters / water cooler of capacity up to 150 liters of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 151 | Material and labour for gas charging of refrigerator of capacity up to 310 Liters with R - 22 / R-134A / R-438A / R-600A or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/bracing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge. |
| 152 | Supply and fix in replacement of following spare parts suitable for refrigerator of capacity up to 310 Liters, single phase, 230 V, 50 HZ, AC of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 153 | Hermetically sealed reciprocating type / rotary type compressor unit including gas charging |
| 154 | Compressor start relay |
| 155 | Overload relay |
| 156 | Copper condenser coil |
| 157 | Thermostat |
| 158 | Refrigerant filter drier |
| 159 | Heater |
| 160 | PCB |
| 161 | Freezer unit |
| 162 | Timer |
| 163 | Bimetal |
| 164 | Material and labor for gas charging of water cooler of capacity 40 / 80 Liters to 150 / 150 Liters with R - 22 / R-134A or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/bracing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge. |
| 165 | Supply and fix in replacement of following spare parts suitable for water cooler of capacity 40 / 80 Liters to 150 / 150 Liters of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 166 | Hermetically sealed reciprocating type / rotary type compressor unit for 40 / 80 Liters capacity including gas charging. |
| 167 | Hermetically sealed reciprocating type / rotary type compressor unit for 60 / 120 Liters capacity including gas charging. |
| 168 | Compressor start relay |
| 169 | Overload relay |
| 170 | Copper condenser coil |
| 171 | Thermostat |
| 172 | Chromium plated self closing push cock tap 15mm with all fixing accessories complete |
| 173 | PVC waste water pipe |