Tender For Provision Of Fasf For Sigar Mil Stn At Sigar Under Ge 872 Ews - Lumpsum Price Workedout By The Tenderer For Building Works As Listed In Schedule ‘A’ Part-I ( A ) 3 Schedule A Part-I ( B ) ; Design And Building Worksnote :- This Schedule Is Not Pre-Priced By Mes And The Pre-Priced Rate Indicated As Rs. 0.00 Under Col - 5 Signifies This Fact Only. 4 Design And Construction Ofgarrage Building For B Veh, Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings No. Cesz / Lkb-Sig / 2022 / Ar-39 Dt-10.11.22 Sh 1 / 2 To 2 / 2 And Drg No. Cesz / Lkb-Sig / 2022 / Sof-55 Dt-10.11.22 Sh 3 / 4 5 Design And Construction Ofsub-Fire Station Building , Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings Nocesz / Lkb-Sig / 2022 / Ar-40 Dt-10.11.22 Sh 1 / 3 To 3 / 3 And Drg No. Cesz / Lkb-Sig / 2022 / Sof-55 Dt-10.11.22 Sh 3 / 4 6 Design And Constructionsingle Living Accnfor 03Havs And 46 Ors , Double Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings No Cesz / Lkb-Sig / 2022 / Ar-44 Dt-10.11.22 Sh 1 / 6 To 6 / 6 7 Design And Construction Of Cook House And Dining Hall For 49 Pers, Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings Nocesz / Lkb-Sig / 2022 / Ar-45 Dt-10.11.22 Sh 1 / 2 To 2 / 2 8 Design And Construction Of200000 Gallons Rccug Sump In Rcc Construction With Permanent Specification Including , Sesmic Consideration Of Zone V, Etc.With Permanent Specification Complete All As Specified And Shown On Drawings. 9 Design And Construction Of Pump House Building Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings No.Cesz / Lkb-Sig / 2022 / Ar-46 Dt-10.11.22 Sh 1 / 2 To 2 / 2 And Drg No. Cesz / Lkb-Sig / 2022 / Sof-55 Dt-10.11.22 Sh 4 / 4 10 Design And Construction Of Pump House Cum Chlorination Plant. Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings No Cesz / Lkb-Sig / 2022 / Ar-47 Dt-10.11.22 Sh 1 / 1And Drg No. Cesz / Lkb-Sig / 2022 / Sof-55 Dt-10.11.22 Sh 4 / 4 11 Design And Construction Ofsub Stn Building For 11Kv, Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings No Cesz / Lkb-Sig / 2022 / Ar-49 Dt-10.11.22 Sh 1 / 2 To 2 / 2 And Drg No. Cesz / Lkb-Sig / 2022 / Sof-55 Dt-10.11.22 Sh 3 / 4 12 Design And Construction Of Guard House And Ancilllaries & Armoury Building, Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings No Cesz / Lkb-Sig / 2022 / Ar-50 Dt-10.11.22 Sh 1 / 4 To 4 / 4 13 Design And Construction Of Storage Cum Drying And Ironing Buildingsingle Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings Nocesz / Lkb-Sig / 2022 / Ar-52 Dt-10.11.22 Sh 1 / 2 To 2 / 2 14 Design And Construction Ofmt Driver Standby And Changing Room Building, Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings Nocesz / Lkb-Sig / 2022 / Ar-51 Dt-10.11.22 Sh 1 / 3 To 3 / 3 15 Design And Construction Of Receipt And Issue Building, Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings Nocesz / Lkb-Sig / 2022 / Ar-55 Dt-10.11.22 Sh 1 / 2 To 2 / 2 16 Design And Construction Of Pump House For Bore Well No 2, Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings Nocesz / Lkb-Sig / 2022 / Ar-53 Dt-10.11.22 Sh 1 / 1And Drg No. Cesz / Lkb-Sig / 2022 / Sof-55 Dt-10.11.22 Sh 4 / 4 17 Design And Construction Ofjco Single Living Accn, Single Storey Rcc Framed Construction With Permanent Specification Includingwater Proofing Treatment To Roof, Sesmic Consideration Of Zone V, Complete All As Specified And Shown On Drawings No Cesz / Lkb-Sig / 2022 / Ar-54 Dt-10.11.22 Sh 1 / 1 And Drg No. Cesz / Lkb-Sig / 2022 / Sof-55 Dt-10.11.22 Sh 3 / 4 18 Note For Items Sr. No. 2.01 To2.14 ( Except 2.05 ) -Quoted Amount Shall Be Inclusive Of Cost Of Following Items- ( A ) .Design And Construction Of Buildings / Structures ( B ) .Third Party Vetting From Any Iits / Nits. ( C ) Cost Of Fitting And Fixtures And Finishing Work As Specified In Respective Drawing Listed In List Of Drawing Except Items Specified In Sch ÁPart-Iii, Iv, Ix, X And Xvi Which Shall Be Measured And Paid Under Respective Schedule. Note For Item Srl No 2.05 Design And Construction Of Ug Sump Including All Fittings And Fixtures To Make It Fully Functional. 19 Lumpsum Price Worked Out By The Tenderer For Site Clearance, Site Developments & Earth Works As Listed In Schedule ‘A’ Part-Ii. 20 Lumpsum Price Worked Out By The Tenderer For Internal Water Supply As Listed In Schedule ‘A’ Part-Iii. 21 Lumpsum Price Worked Out By The Tenderer For Internal Electrifications As Listed In Schedule ‘A’ Part-Iv. 22 Lumpsum Price Worked Out By The Tenderer For Roads / Path / Culvert / Hard Standing As Listed In Schedule ‘A’ Part-V. 23 Lumpsum Price Worked Out By The Tenderer For Sewage Disposal As Listed In Schedule ‘A’ Part-Vi. 24 Lumpsum Price Worked Out By The Tenderer For Area Drainage As Listed In Schedule ‘A’ Part-Vii. 25 Lumpsum Price Worked Out By The Tenderer For Boundry Wall / Security Fencing / Gate As Listed In Schedule ‘A’ Part-Viii. 26 Lumpsum Price Worked Out By The Tenderer For Hot Water Supply As Listed In Schedule ‘A’ Part-Ix. 27 Lumpsum Price Worked Out By The Tenderer For Colling Appliances As Listed In Schedule ‘A’ Part-X. 28 Lumpsum Price Worked Out By The Tenderer For Lighting Protection As Listed In Schedule ‘A’ Part-Xi. 29 Lumpsum Price Worked Out By The Tenderer For Fire Alarm System As Listed In Schedule ‘A’ Part-Xii. 30 Lumpsum Price Worked Out By The Tenderer For Chemical Earthing As Listed In Schedule ‘A’ Part-Xiii. 31 Lumpsum Price Worked Out By The Tenderer For External Water Supply As Listed In Schedule ‘A’ Part-Xiv. 32 Lumpsum Price Worked Out By The Tenderer For Fire Fighting System As Listed In Schedule ‘A’ Part-Xv. 33 Lumpsum Price Worked Out By The Tenderer For External Electrification As Listed In Schedule ‘A’ Part-Xvi. 34 Sch A Sec-Xviii ( Miscellaneous Items ) Note : This Schedule Is Not Pre-Priced By Mes And The Pre-Priced Rate Indicated As Rs 0.00 Under Col. 5 Siginifies This Fact Only. 35 Preparation & Submission Of Soil Investigation Report In Sixupulate By Conducting Soil Investigation After Making Bore Holes 150 Mm Dia In Any Type Of Soil Up To Max 15.0 M Depth Or Upto The Depth Of Refusal, Collecting, Disturbed And Undisturbed Samples, Conducting Standard Penetration Test ( Spt ) At 1.5 Mtr Interval Thereafter Or On Change Of Strata And Laboratory Test Like Direct / Triaxial Shear Test, Sieve Analysis Grain Distribution Curves & Pattern In Bore Holes, Type Of Soil, C Value, Bulk Density, Natural Moisture Content, Dry Density, Water Table, Specific Gravity, Atterberg Limit, Hydrometer Analysis, Liquid & Plastic Limit, Swelling Index, Void Ratio And Porosity, Unconfined Compressure Test Evaluation Of Liquifaction Potential Is-1893 Part I -2016.Compilation Of Field And Laboratory Test Results, Preparation Of Reports, Recommendation For Depth Of Embedment, Water Table, Submission Of All Report Booklets 06 ( Six ) Copies With Cd 01 ( One ) Copy Including Photographs & Videography Duly Indicating The Following :- ( I ) Evaluation Of Safe Bearing Capacity Of The Soil With Respect To Shear Failure Test And Permissible Settlement ( Total And Differential ) Alongwith Recommendation About Type Of Foundation And Minimum Depth Offoundation To Be Adopted For Subject Work. ( Ii ) Evaluation Of Liquefaction Potential. ( Iii ) Specific Suggestions If Any For Soil Treatment If Required Below Foundation / Ground Floor / Roads And Type Of Treatment To Be Carried Out. 36 Item No 18.01 Cont... ( Iv ) Bore Log Diagram Duly Showing The Different Layers Of Strata Met Alongwith Their Depths.Note : ( I ) Each Bore Hole Will Be Measured Upto Depth Of Refusal Or 15.00 M Whichever Is Earlier. ( Ii ) Rate Includes Mobilsation Of T&P As Per Requirement And Direction Of The Engr-In-Charge. ( Iii ) Rate Includes Vetting Of Geotechnical Investigation Reportfrom Any Nit ( National Institute Of Technology ) / Iits ( Indian Institute Of Technology ) And Submit Hard Copy & Soft Copy In Six Numbers / Sets For Approval Of Accepting Officer. 37 Preparation & Submission Of Soil Investigation Report In Sixupulate By Conducting Soil Investigation With Trial Pit Of Size 1.2 X 1.2 X 1.2M After Making Bore Holes 150 Mm Dia In Any Type Of Soil Up To Max 15.0 M Depth Or Upto The Depth Of Refusal, Collecting, Disturbed And Undisturbed Samples, Conducting Standard Penetration Test ( Spt ) At 1.5 Mtr Interval Thereafter Or On Change Of Strata And Laboratory Test Like Direct / Triaxial Shear Test, Grain Distribution Curves & Pattern In Bore Holes, Type Of Soil, C Value, Bulk Density, Natural Moisture Content, Dry Density, Water Table, Specific Gravity, Atterberg Limit, Hydrometer Analysis, Liquid & Plastic Limit, Swelling Index, Evaluation Of Liquifaction Potential Is-1893 Part I -2016. 38 Item No 18.03 Cont.. Compilation Of Field And Laboratory Test Results, Preparation Of Reports, Recommendation For Depth Of Embedment, Water Table, Submission Of All Report Booklets 06 ( Six ) Copies With Cd 01 ( One ) Copy Including Photographs & Videography Duly Indicating The Following :- ( I ) Evaluation Of Safe Bearing Capacity Of The Soil With Respect To Shear Failure Test And Permissible Settlement ( Total And Differential ) Alongwith Recommendation About Type Of Foundation And Minimum Depth Offoundation To Be Adopted For Subject Work. ( Ii ) Evaluation Of Liquefaction Potential. ( Iii ) Evaluation Of K-Value. ( Iv ) Specific Suggestions If Any For Soil Treatment If Required Below Foundation / Ground Floor / Roads And Type Of Treatment To Be Carried Out. ( V ) Bore Log Diagram Duly Showing The Different Layers Of Strata Met Alongwith Their Depths.Note : ( I ) Each Bore Hole Will Be Measured Upto Depth Of Refusal Or 15.00 M Whichever Is Earlier. ( Ii ) Rate Includes Mobilsation Of T&P As Per Requirement And Direction Of The Engr-In-Charge. ( Iii ) Rate Includes Vetting Of Geotechnical Investigation Reportfrom Any Nit ( National Institute Of Technology ) / Iits ( Indian Institute Of Technology ) And Submit Hard Copy & Soft Copy In Six Numbers / Sets For Approval Of Accepting Officer. 39 Bringing Approved Earth ( As Approved By Garrison Engineer ) From Sources Outside Defence Land Including All Cost Such As Royalty If Any , Transportation , Taxes, Etc. For Area Filling / Area Development Upto Mgl Level Including Raising Of Original Ground Level Upto Mgl By Approved Earth And Includingspreading In Layers Not Exc 30Cm Thick Each Layer , Watering , Compaction With 8 Tonne To 12 Tonne Power Roller And Finished To Required Size And Shape Etc.Notes: ( I ) Earth Required For The Item, Shall Be Supplied By Contractor, From Out Side Mod Land Of Any Lead, At His Own Own Arrangement. ( Ii ) All Cost Of Procurement Of Earth Including Cost Of Transportation, Compaction, Royalties, Tax Etc Shall Be Deemed To Be Included In The Unit Rate Quoted By The Contractor. ( Iii ) With Reference To Clause 3.6 Of Mes Part-Ii On Serial Page No-21 It Is Clarified That Measurement Of The Above Item Shall Be Of Finished Embankment / Traverse Of Filled Earth After Consolidation / Compaction And 5% Deduction Shall Be Made From Measured And Calculated Volume To Allow For Increase In Bulk. 40 Material & Labor For On Site Hume Pipe Septic Tank For 10 Users Designed To Carry Sewage And Sullage Water, Excavation In Any Type Of Soil, Pcc 1:4:8 Below Foundation, Vent Shaft, Connection Etc., Complete All Specified And Directed. 41 M&L For Rcc Septic Tank 100 Users With Upflow Filter Type Designatedto Carry Sewage And Sullage And Sullage Water, Excavation In Any Type Of Soil, Pcc 1:4:8 Below Foundation, Rcc M-30 Design Mix In Walls, Base Slab, Baffle Walls And Roof Slab Including Beams Etc With Vent Shaft, Manhole Openings With Cover Connection Etc, Complete With Effective Depth 1.5 Mtr And Over All Depth Of 3 Mtr For Complete All Specified And Shown On Drawing No Cesz / 2020 / Std-02 Sheet 1 / 2 To 2 / 2 42 Construction Of Brick Masonry Soak Well Of Size 1.2 M Dia & 3.00 M Depth With All Fittings And Fixtures Complete All As Specified And Shown On Drawing No Cesz / 2020 / Td / 45 Sheet 1 / 2 To 2 / 2 43 Construction Of Brick Masonry Soak Well Of Size 2.40 M Dia & 4.50 M Depth With All Fittings And Fixtures Complete All As Specified And Shown On Drawing No. Sz / 2020 / Td / 45 Sheet 1 / 2 To 2 / 2 44 Supply, Installation, Testing & Commissioningofheater Water Storage Type Electric Geyser ( Vertical Cylindrical Type ) 25 Litre Capacity With Bee 5 Star Rating ( Minimum ) And Metallic Body, Porcelain Enamel Glass Lined Inner Tank Including Fixing Arrangement With Providing And Including Suitable Capacity Flexible Cable 3 Core With 3-Pin Plug Of 16A Capacity Maximum 2Metre Length, Pvc Connection Pipe Of Suitable Length For Hot And Cold Water, Fixing On Walls With And Including All Necessary Fitting Material I.E. Mild Steel Bolts ( Bolts To Be Grouted ) , Nuts, Washers, Etc Complete All As Specified And As Directed. 45 Supply And Fix Refrigerator Double Door, Electric Driven ( Single Phase ) , Capacity 340 Litres With Smart Inverter Compressor, Frost Free, Multi Air Flow, Anti Bacterial Gasket, 5 Star Rating Complete All Specified And Directed. 46 Supply And Fix Refrigerator Double Door, Electric Driven ( Single Phase ) , Capacity 360 Litres With Smart Inverter Compressor, Frost Free, Multi Air Flow, Anti Bacterial Gasket, 5 Star Rating Complete All Specified And Directed. 47 Chemical Earthing With Copper Earth Plate 90X60cmx5mm Buried Directly In Gound ( Earth Pit Not Less Than 2.25M Deep Below Normal Ground Level ) With Top Edge Plate Not Less Than 1.5M Deep Below Normal Ground Level Connected To Copper Earth Strip 50X6mm By Means Of Bolts, Nuts, Check Nuts And Washers Made Of Glavanized Iron, 20Mm Dia Gi Pipe ( Med Grade ) For Watering, 15Mm Dia Gi Pipe ( Light Grade ) For Protection Of Earth Lead Wire, Including Necesary Earth Work In Any Type Of Soil, Pcc ( 1:3:6 ) Type C1 Concerete Pit, Rcc ( 1:1.5:3 ) Type A1 Precast Cover ( 54 X 54 X 5Cm ) Duly Reinforced With Including 8Mm Dia Tmt Bar @ 150Mm C / C Both Ways, One Lifting Handle Made Of 8Mm Dia Tmt Bar, Embebed In Precast Cover Slab Complete All As Specified And Shown In Electrical Plate No 3 Of Ssr Part-I Including Testing On Completion. 48 Chemical Earthing With Copper Earth Plate 30X30cmx3mm Buried Directly In Gound ( Earth Pit Not Less Than 2.25M Deep Below Normal Ground Level ) With Top Edge Plate Not Less Than 1.5M Deep Below Normal Ground Level Connected To Copper Earth Strip 25X3mm By Means Of Bolts, Nuts, Check Nuts And Washers Made Of Glavanized Iron, 20Mm Dia Gi Pipe ( Med Grade ) For Watering, 15Mm Dia Gi Pipe ( Light Grade ) For Protection Of Earth Lead Wire, Including Necesary Earth Work In Any Type Of Soil, Pcc ( 1:3:6 ) Type C1 Concerete Pit, Rcc ( 1:1.5:3 ) Type A1 Precast Cover ( 54 X 54 X 5Cm ) Duly Reinforced With Including 8Mm Dia Tmt Bar @ 150Mm C / C Both Ways, One Lifting Handle Made Of 8Mm Dia Tmt Bar, Embebed In Precast Cover Slab Complete All As Specified And Shown In Electrical Plate No 3 Of Ssr Part-I Including Testing On Completion. 49 Material & Labour For Earthing With Galvanised Steel Earth Plate Electrode Of Size 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25M Deep Below The Ground Level ) With Top Edge Of The Plate Not Less Than 1.5M Below Normal Ground Level, Connected To The Galvanised Earth Lead By Means Of Bolts, Nuts Check Nuts And Washers Of Galvanised Iron Or Steel Using Gi Strip 32 X 6Mm As Earthing Lead Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completion Including Necessary Excavation And Earth Work In Soft / Loose Soil, Returning Filling, Disposal Of Surplus Soil, Earth Pit In Pcc 1:3:6 Type C-1 Using 20Mm Graded Stone Aggregate Pit, Funnel, 20Mm Dia Gi Medium Grade Watering Pipe, 40Mm Dia Gi Light Grade Earth Lead Protection Pipe, Ci Frame And Cover, Wire, Copper Lugs Etc Mesh, Charcoal And Common Salt In Alternate Layers Complete As Shown In Electrical Plate No. 3 Of Ssr Part-I All As Specified And Directed By Engr-In-Charge. 50 Material & Labour For Earthing With Galvanised Steel Earth Plate Electrode Of Size 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25M Deep Below The Ground Level ) With Top Edge Of The Plate Not Less Than 1.5M Below Normal Ground Level, Connected To The Galvanised Earth Lead By Means Of Bolts, Nuts Check Nuts And Washers Of Galvanised Iron Or Steel Using Gi Wire 4Mm Dia As Earthing Lead Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completion Including Necessary Excavation And Earth Work In Soft / Loose Soil, Returning Filling, Disposal Of Surplus Soil, Earth Pit In Pcc 1:3:6 Type C-1 Using 20Mm Graded Stone Aggregate Pit, Funnel, 20Mm Dia Gi Medium Grade Watering Pipe, 40Mm Dia Gi Light Grade Earth Lead Protection Pipe, Ci Frame And Cover, Wire, Copper Lugs Etc Mesh, Charcoal And Common Salt In Alternate Layers Complete As Shown In Electrical Plate No. 3 Of Ssr Part-I All As Specified And Directed By Engr-In-Charge. 51 M&L For Earthing Complete With Copper Earth Plate Of Size600x600x3.15 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level Connected To Earth Lead Wire Of Copper Strip Of Size 20 X 3 Mm Dia By Means Of Nuts / Bolts And Washers, Check Nuts Of Galvanized Iron Or Steel Including 15Mm Dia Gi Pipe Light Grade Upto 1.5 Mtr Below Gl For Protection Pipe, Excavation And Earth Work Charcoal Dust, Common Salt, Pcc 1:3:6Type C-1 Chamber With Cover And Rcc1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate Reinforced With 6Mm Dia Round Bars @ 75Mm C / C Both Way With Ms Handle 12Mm Dia Pgi Funnel And Wire Mesh All As Shown In Electrical Plate No 5 Of Ssr Part-I Connected To Ear Thing Test Point All As Specified Or Indicated Including Testing On Completion All As Directed By Engr-In-Charge. 52 Supply And Fix Gi Strip 32Mm X 6Mm Buried In Ground Complete All As Specified. 53 Supply, Laying & Testing Pvc Insulated, Pvc Sheathed Cable Galvanized Steel Strip Or Wire Armoured, Electriccables ( Heavy Duty ) With Stranded Copper Conductor Of Size 1.5 Sq Mm , 2 Core, 1100 Volts Grade. Complete All As Specified And Directed. 54 M& L For Sand Cushioning In Trenches For Protection Of Under Ground Cable Provided In Layers Of Sand As 8 Cm Before Laying The Cable And 15 Cm Deep After Laying Cable Complete All As Specified And Directed.Note : Punned Thickness Shall Be Measured And Paid. 55 Supply And Fix Junction Box Dia 100 X 65 High Dust Proof Dust Tight / Totally Enclosed Typecomplete All As Specified And Directed. 56 Supply And Fix Epoxy Powder Coated Flameproof / Weatherproof Lighting Distribution Panel Having Ip66 Protection Enclosure Of Cast Aluminum Alloy Material. The Distribution Board Should Be Spn 8 Way Including 01 No. Incommer Mcb 2 Pole 32 Amps C Type And 5 No. Outgoing Mcbs 6 Amps & 01 No 10 Ams Mcb With Complete Internal Common Bus-Bar &Wiring Up To Terminals All As Directed. 57 Supply And Fixing Of Cimfr Certified Flameproof Cum Waterproof Light Fitting Of 60W, Recommendedfor Gas / Vapour Group Of Iia & Iib And Zone 1 & 2 Ip65 Protection Ip65 Protection, Cast Aluminum Alloy Material And Heat And Impact Resistance Toughen A Clear Glass Having Anti Corrosive Epoxy Powder Coated Finish Complete With All Accessories Pre Wired And Including Connecting Up With Three Core Flexible Copper Conductor Cable With Suitable Size Drawn In Flexible Steel Conduit Complete All As Specified And As Directed. 58 Drilling Trial Bore Hole By Odex Full Casing Method Through Any Kind Of Soil, Boulder Rock For A Bore Of 200Mm Dia Tube Well As Required As Per Site Condition Upto 200 Mtr Depth As Per Is-2800 Including Disposal Of Soil From The Site Complete .. ( Note: This Item Will Be Considered For Payment If Borewell Is Not Successfull At Site As Directed By The Engr-In-Charge ) 59 Drilling And Development Of Trial Bore Hole By Odex Full Casing Method Through Any Kind Of Soil, Boulder Rock For A Bore Of 200Mm Dia Tube Well As Required As Per Site Condition Upto 60 M From Ground Level As Per Is-2800 Including Disposal Of Soil From The Site Completeall As Specified And Directed By Engr-In-Charge 60 Drilling And Development Of Trial Bore Hole By Odex Full Casing Method Through Any Kind Of Soil, Boulder Rock For A Bore Of 200Mm Dia Tube Well As Required As Per Site Condition Exc 60 Mtr An N.Exc 120Mtr From Ground Level As Per Is-2800 Including Disposal Of Soil From The Site Completeall As Specified And Directed By Engr-In-Charge 61 Drilling And Development Of Trial Bore Hole By Odex Full Casing Method Through Any Kind Of Soil, Boulder Rock For A Bore Of 200Mm Dia Tube Well As Required As Per Site Condition Exc 120 Mtr An N.Exc 150Mtr From Ground Level As Per Is-2800 Including Disposal Of Soil From The Site Completeall As Specified And Directed By Engr-In-Charge 62 Assembling, Lowering And Fixing Into Bore Holes, 200 Mm Bore, Mild Steel Erw ( Isi Marked ) , Casing Pipe Having Wall Thickness 6Mm As Per Is-4270-2001 ( Steel Tube Or Water Well ) , Heavy Grade, Plain End, Blank Jointed With Collar Through Electric Resistance Of High Frequency Induction Welding For Increasing Of Length Of Pipe Including Necessary Fittings And Providing Two Coats Of Black Bituminous Paint ( For Drinking Purpose ) Internally And Externallycompleteall As Specified And Directed By Engr-In-Charge 63 Assembling, Lowering And Fixing Into Bore Holes, 150 Mm Bore, Mild Steel Erw ( Isi Marked ) , Casing Pipe Having Wall Thickness 6Mm As Per Is-4270-2001 ( Steel Tube Or Water Well ) , Heavy Grade, Plain End, Blank Jointed With Collar Through Electric Resistanceof High Frequency Induction Welding For Increasing Of Length Of Pipe Including Necessary Fittings And Providing Two Coats Of Black Bituminous Paint ( For Drinking Purpose ) Internally And Externallycompleteall As Specified And Directed By Engr-In-Charge 64 Assembling, Lowering And Fixing In Position, 150Mm Bore, Low Carbon Glavanised Steel ( Lcg ) Strainer With Continuous Slot Screen ( V-Wire Strainer ) Of 0.75 To 1.00 Mm Slot Width To Give An Open Area Of 30.4% Conforming To Relevant Is And Providing Two Coats Of Black Bituminous Paint ( For Drinking Purpose ) Internally And Externallycompleteall As Specified And Directed By Engr-In-Charge 65 M&L For Electric Logging In Pilot Bore For Precise Delineation Of Granular Zones As Also The Quality Of Ground Water Including Report Interpretation Complete All As Specified And As Directed. ( Note:- Electric Logging Shall Be Carried Out By Any Approved Govt Agency ) 66 S&F Well Cap Suitable For 200 Mm Bore Housing Pipe Made Out Of 6 Mm Thick Steel Plate Complete ( Use For Water Well ) , Heavy Grade, Plain End, Blank Jointed With Collar Through Electric Resistance Welding Completeall As Specified And Directed By Engr-In-Charge Note : After Completion Of The Work Well Cap Will Be Used To Keep The Bore Well Closed Until The Submersible Pumping Set Is Installed. 67 M & L For Developement Of Tube Well With Compressed Air And After With 25% Extra Capacity Pump By Pumping Muddy Water For 36 Hrs Completeall As Specified And Directed By Engr-In-Charge 68 Yield Test For The Above Bore Well By Continuously Pumping For 16 Hours To Determine Safe Pumping Yield And Preparation Of Test Sheet Per Hour Specifying Necessary Parameters Of Testing Complete All As Specified And Directed By Engr-In-Charge 69 Material And Labour For Packing Pea Gravel 3 To 5 Mm ( Or As Per Geologist Report ) Of Size As Per Is Of Natural Shapebrought Directly From River Bed Duly Screened And Packing Around The Casing Pipe Of Ms To Entire Depth Of Tubewell Upto Ground Level Complete All As Specified & As Directed. 70 Supply & Laying Galvanized Steel Tubing Heavy GradeOf Size 80 Mm Bore With Flanged Ends ( Threaded & Welded ) Long Gi Sockets And Gi Fittings Incl Bolts, Nuts & Washers In Borewell All As Specified& Directed By Eic. 71 Submersible Pump, Electric Driven 415 V, Tp Suitable For 250 Mm Dia Bore Well ( Casing Pipe Size 300 / 350 Mm ) Supply And Install Complete Upto 10 Whp Inclusive Of 40 Metre Long Submersible Cablecomplete All As Specified And As Directed 72 Testing Of Raw Water & Treated Water From Approved Govt Lab For Potability By Doing Chemical ( Specially For Iron ( Fe, Fluroide ( F ) And Arsenic ( As ) ) And Bacteriological Analysis As Per Norms Of Who And Submission Of Test Reports To The Entire Satisfaction Of Engineer-In-Charge. 73 Supply & Laying And Jointing 100Mm Diaductile Iron Pipe, With Spigot And Socket Ends Suitable For Push On Rubber Joint Centrifugally Castclass “K-9” Inner Side Cement Lining And Outer Side Black Bitumen Coatinglaid In Trenches Including Push On Rubber ( Epdm ) Ring With Isi Markedcomplete All As Specified And Directed.. 74 Supply & Laying And Jointing 150Mm Diaductile Iron Pipe, With Spigot And Socket Ends Suitable For Push On Rubber Joint Centrifugally Castclass “K-9” Inner Side Cement Lining And Outer Side Black Bitumen Coatinglaid In Trenches Including Push On Rubber ( Epdm ) Ring With Isi Markedcomplete All As Specified And Directed.. 75 Supply & Laying And Jointing 300Mm Diaductile Iron Pipe, With Spigot And Socket Ends Suitable For Push On Rubber Joint Centrifugally Castclass “K-9” Inner Side Cement Lining And Outer Side Black Bitumen Coatinglaid In Trenches Including Push On Rubber ( Epdm ) Ring With Isi Markedcomplete All As Specified And Directed.. 76 Supply & Laying And Jointing 200Mm Diaductile Iron Pipe, With Spigot And Socket Ends Suitable For Push On Rubber Joint Centrifugally Castclass “K-9” Inner Side Cement Lining And Outer Side Black Bitumen Coatinglaid In Trenches Including Push On Rubber ( Epdm ) Ring With Isi Markedcomplete All As Specified And Directed.. 77 Supply & Laying And Jointing 200Mm Diaductile Iron Pipe, With Spigot And Socket Ends Suitable For Push On Rubber Joint Centrifugally Castclass “K-7” Inner Side Cement Lining And Outer Side Black Bitumen Coatinglaid In Trenches Including Push On Rubber ( Epdm ) Ring With Isi Markedcomplete All As Specified And Directed.. 78 Supply & Laying And Jointing 150Mm Diaductile Iron Pipe, With Spigot And Socket Ends Suitable For Push On Rubber Joint Centrifugally Castclass “K-7” Inner Side Cement Lining And Outer Side Black Bitumen Coatinglaid In Trenches Including Push On Rubber ( Epdm ) Ring With Isi Markedcomplete All As Specified And Directed.. 79 Supply & Laying And Jointing 100Mm Diaductile Iron Pipe, With Spigot And Socket Ends Suitable For Push On Rubber Joint Centrifugally Castclass “K-7” Inner Side Cement Lining And Outer Side Black Bitumen Coatinglaid In Trenches Including Push On Rubber ( Epdm ) Ring With Isi Markedcomplete All As Specified And Directed.. 80 Supply & Laying And Jointing 80Mm Diaductile Iron Pipe, With Spigot And Socket Ends Suitable For Push On Rubber Joint Centrifugally Castclass “K-7” Inner Side Cement Lining And Outer Side Black Bitumen Coatinglaid In Trenches Including Push On Rubber ( Epdm ) Ring With Isi Markedcomplete All As Specified And Directed.. 81 Supplying And Fixing Reflux Valves ( Nrv ) With By Pass Arrangement Supplied And Installed Complete Of Size 100 Mm Complete All As Specified And Directed. 82 Supply And Fix Cast Iron Air Valves With Two Air Outlets, Conforming To Is 14845 Of Size 100 Mm Dia Bore And Fixing Up In Cast Iron Water Supply Mains Complete All As Specified And Directed. 83 Supply And Fix Cast Iron Air Valves With Two Air Outlets, Conforming To Is 14845 Of Size 50 Mm Dia Bore And Fixing Up In Cast Iron Water Supply Mains Complete All As Specified And Directed. 84 Supply And Fix Foot Valve Conforming To Is 4038, 100 Mm Diacomplete All As Specified And Directed. 85 Supply And Install Pumping Sets, Centrifugal, Electric Driven, Of Capacity 3 Whpand Pcc Foundation Complete All As Specified And Directed. 86 Supply And Installpumping Sets, Centrifugal, Electric Driven, Of Capactity10 Whp And Pcc Foundationcomplete All As Specified And Directed. 87 Supply, Install, Connect, Testing And Commissioning Of 3 Phase 4 Wire 50 Hz 415 Volts, Bus Bar Chamber With Tinned Copper Bus Bar Fp 200 Ampsupported On Frp Insulator And Heat Shrinked Insulating Sleeves, Indoor Lt Panel, Compartmentalised Cubical Type With Canopy, Dust And Vermin Proof, Free Standing Floor Mounting Type Mountedon And Incl 1:3:6 Pcc Platform With Required Mounting Channel, Feeder Pillar Box Fabricated Out Of 2.0Mm Thick Crca Steel Sheet Duly Pre Treated And Powder Coated Factory Fabricated Incl Cable Glands Of Suitable Sizes And Consisting The Following:-Incoming:- ( A ) Mccb, Fp 125 Amps, Relay Range 100-125 Amps With Breaking Capacity 30 Ka - 01 No ( B ) Changeover Switch 4 Pole 160 A - 01 No ( C ) Led Display In 96 X 96 Sqmm Flush Mounted Case Accuracy Class 1.0, 3Phase, 4 Wire, Panel Mounted Multi Function Meter Make L&T Complete With Connected Copper Conductor Wiring - 01 No ( D ) Phase Indicating Lamps Led Type For Ryb Phases - 1 Set ( E ) Ct Coil 100 / 5A Ct - 03 Nos Outgoing :- ( A ) Mccb, Tp, 100Amps, Relay Range40-50 Amps With Breaking Capacity 25 Ka - 03 No ( B ) Mccb, Tp, 100Amps, Relay Range 25-32 Amps With Breaking Capacity 25 Ka - 02 No ( C ) Mcb Dp 20 Amps - 02 Nos ( D ) Ct Coil 125 / 5A Ct ( Set Of 03 ) - 02 Nos ( E ) Digital Ammeter, Three Phase 5A, Accuracy Class 1.0, Flush Mounting Type 96X96 Mm, -02 Nos ( F ) Star Deta Starter Suitable For20 Hp -2 Nos 88 Construction Of Valve Pit Type A Ofpcc Block Masonryand Of Size 90 Cm X 90 Cm X90 Cm ( Inner Dimension ) With All Fittings And Fixtures Complete All As Specified And Shown On Drawing No. Td / Em / 6 Sheet 1 / 2 89 Construction Of Valve Pit Type A Ofpcc Block Masonryand Of Size 120 Cm X 120 Cm X120 Cm ( Inner Dimension ) With All Fittings And Fixtures Complete All As Specified And Shown On Drawing No. Td / Em / 6 Sheet 1 / 2 90 Supply And Fix Bleaching Dozer Bucket Type Of Capacity 145 Litrescomplete All As Specified And Directed. 91 S & F Aviation Light Of 100 Watt Yellow Painted Lm6 Alluminium Alloy Housing With Heat Resistant & Toughenedglass Coverand Wire Guard Fitting Built With Controll Gear, & Eye Bolt On Top Of Overhead Tankcomplete All Specified & Directed 92 S & F Electronic Water Level Indicator For Overhead Tank Including All Connecting Items Complete All Specified & Directed 93 Supply, Installation & Commissioning Horizontal Monoblock Pump 10 Hp Capacity, 2 Stage, Suction And Delivery Size 80Mm X 65Mm Having Discharge 20 Liters Per Second At 40.00 Metre Head Suitable For Working Voltage 415 Volts, 3 Phase And Testing, Complete All As Specified And As Directed. 94 Supply And Fix Strainer Y Type Conforming To Is, Size 300 Mm Dia 95 Supplying And Fixing Reflux Valves ( Nrv ) With By Pass Arrangement Supplied And Installed Complete Of Size 300 Mm Complete All As Specified And Directed. 96 Supplying And Fixing Reflux Valves ( Nrv ) With By Pass Arrangement Supplied And Installed Complete Of Size 150 Mm Complete All As Specified And Directed. 97 Supply & Fixing Sluice Valve Cast Iron Body Class Pn 1.6 With Flanged Ends Drilled Suitable For Bore Of Pipe 300Mm Isi Marked Havingbrass Spindle With Iron Wheel At Top Including Necessary Fixing Arrangements Such As Mild Steel Nuts, Bolts, Washers, Gaskets, Etc. Including Testing, Complete All As Specified And As Directed. 98 Supply And Fix Ms Flanged Pipe 80Mm Nb Heavy Duty For Multi Storied Building Duly Painted With 2 Coats Of Synthetic Enamel Paint Over Coat Of Zinc Chromate Primer Complete All As Specified And As Directed. 99 Supply And Lay 20Mm Diapipe Galvanized, “Heavy Class”, Including Fittings Complete All As Specified And As Directed. 100 Supply And Fixing Of Rcc Post Of Size 75X75x500 Mm With 6 Mm Tmt Barcomplete All As Specified And As Directed. 101 Supply And Fix Hose Box For Hose Reel Of 20 Mm Size Of 30 Meter Length Complete With Coupling Branch Pipe And Nozzle , Ms Sheet 2 Mm Thickness Complete All As Specified And As Directed. 102 M&L Branch Pipe Gun Metal 63Mm Instantaneous Inlet, Made Threaded Outlet, 20Mm Bore Nozzle Short Complete All As Specified And Directed. 103 Supply And Fix 63 Mm Dia 15 Meter Long Hose Conforming To Is 636 Complete With Male And Female Coupling Conforming To Is 903Complete All As Specified And Directed. 104 Supply And Fix 63 Mm Dia Gun Metal Branch Pipe With 12.5 Mm Nozzle Conforming To Is 903 Complete All As Specified And As Directed. 105 Supply And Fix Pressure Gauge 100 Mm Dia With Ball Valve Of Pressure 25 Kg / Sqcmcomplete All As Specified And As Directed. 106 Supply And Fix Pumping Sets, Centrifugal, Electric Driven, Supply And Install Complete Up To 2 Hp Inclusive Of Starter And Pcc Foundation For Washing Of Hose Pipescomplete All As Specified And As Directed. 107 Supply And Fixing Lightning Arrestor Sub Station With All Fittings, Transmission Class, Discharge Capacity 9 Ka Complete All As Specified And Directed. 108 Supply And Installation Of11 Kv, 630 Amp Load Break Switch With 200 Amp Do Set And Earth Switch Complete All As Specifiedand Directed. 109 Supply, Installation Testing And Commissioning 315 Kva Outdoor Type Transformer, Step Down 6Kv / 433V, 3 Phase 50 C / S Ac Double Wound, Core Type Copper Wound, Oil Immersed Naturally Cooled ( Onan ) With External Cooling Tubes, Delta / Star Connection On Primary Side ( 6Kv ) , And Star Connection On Secondary Side ( 433V ) In Accordance Withvector Symbol Dyn-11 And Having Tapping At + / - 2.5%, + / - 5% And + / -7.5% To Be Changed By Means Of Manually Operated Off Load Tap Changing Gear.The Rate Of Temperature Rise After Continuous Fall Load Shall Be All As Specified In Is -2026.The Transformer Shall Be Complete With The Following:- ( A ) Cable Entry Box For Lt On Secondary Side For 3.5 Core 400 Sqmm Xlpe Cable And Ht 3 Core 95 Sq Mm On Primary Side Including Fixing Arrangement As Specified And Directed By Engineer-In-Charge. ( B ) Oil Conservator With Filling Cap, Drain Valve And Oil Level Gauge. ( C ) Dehydrating Breather With Connecting Pipe, First Fill Of Dehydrating Agent And Oil Seal. ( D ) Explosion Relief Vent Mounted On Tank With Double Diaphragm And Equiliser Pipe Connection To Conservator Air Space ( Pressure Release Device ) . ( E ) Air Relief Plug. ( F ) Shut Off Valve Between The Conservator And Bucholz Relay. ( G ) Thermometer Pocket. ( H ) 100 Mm Dial Type Temperature Indicator Having Range 0-120 Degree C Vapour Pressure Type With Maximum Reading Pointer / Max Temp Indicator And Resetting Device With Alarm / Trip Contact And Additional Contacts For Switching On Or Off The Colling Fans. ( J ) Two Earthng Terminals On Tank And Tank Cover With Lugs To Suit 32 Mm X 6Mm Gi Strip. ( K ) Rating And Diagram Plate. 110 Item No 18.75 Cont... ( L ) 100 Mm Dial Type Thermometer For Winding Temperature Indicator Having Range 0 - 120 Degree C Vapour Pressure Type With Maximum Reading Pointer / Max Temp Indicator And Resetting Device With Alarm / Trip Contact And Additional Contacts For Switching On Or Off To Cooling Fans ( M ) Drain Valve With Threaded Adopter. ( N ) Filter Valve With Threaded Adopder ( Top And Bottom ) . ( O ) Sample Valve. ( P ) Inspection Covers. ( Q ) Lifting Lugs. ( R ) Four Plane Rollers, Bidirectional, Hinged Type At The Bottom For Shifting Transformer From One Place To Another Place. ( S ) Top Cover Lifting Eyes. ( T ) Double Float Bucholz Relay With Trip And Alarm Contact. ( U ) Extra Bushing Outside The Cable Box For Providing Independent Earthing. ( V ) First Fill Of Transformer Oil. ( W ) Rail Section And Channelemdedded In Foundation Of Suitable Size In And Including Pcc Platform Of Size 4.0M X 4.0M X 0.60M ( Pcc 1:3:6 ) Including Ramp As Per Manufacturers Recommendations. 111 Supply, Install, Test And Commission Lt Panel Board, Tpn 415 Volts, 50 Hz, Indoor Cubical Type Floor Mounted Cpri Approved Factory Made, Double Doordust And Vermin Proofip-54, Fabricatedout Of Crca Sheet Not Less Than 2 Mm Thickwith 2 Mm Thick For Internal Compartment Duly Powder Coated Fixed On Angle Iron Pedestalmade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Led Indicator Lampryb With Switchgears And The Panel Board Shall Be Provided With Proper Ventillation Including Suitable Size Of Cable Alley Al Bus Bar Suitable For Carrying Of Current1000 Amps With Suitable Connections From Mccb & Out Going To Main Bus Bar Shall Be Carried Out With Tpn Al Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Aluminium Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator Including Necessary Pcc Foundation Of Minimum 0.200 M Height Positioned And Fixed With Suitable Nut, Bolts, Washers Etc To The Mc Pedestal All As Specified And Directed Comprising Of The Following :-Incoming :- ( A ) 630A Mccb, 4Pole, 250-630 A Relay, 70 Ka -1 No ( B ) Lcd Multifunction Meter - 01 No ( C ) Cts 630 / 5 A- Set Of 3 ( D ) Phase Indicator Lamps ( Ryb ) -Set Of 3 ( E ) 1000 Amps Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Incl Insulators, Sleeves Etc ( G ) 630 A, 415 V Manual Change Over, Open Execution -01 No 112 Item No 18.77 Cont.. Outgoing :- ( A ) 400A, Mccb, 4P, 320-400 A Relay, 70 Ka -1 No ( B ) 160A, Mccb, 4P, 43-63 A Relay, 50 Ka -1 No ( C ) 125A, Mccb, 4P, 100-125 A Relay, 36 Ka - 2 Nos ( 1 No Spare ) ( D ) 16A Fp Mcb, C Curve 10 Ka -01 No ( E ) 16A Dp Mcb, C Curve 10 Ka -2 No ( F ) 125A, Mccb, 4P, 100-125 A Relay, 25 Ka- 01 No ( G ) 100A, Mccb, 4P, 32-40 A Relay, 25 Ka-02 Nos ( H ) 100A, Mccb, 4P, 25-32 A Relay, 25 Ka -02 Nos ( H ) 100A, Mccb, 4P, 25-32 A Relay, 25 Ka -02 Nos 113 Supply, Install, Test And Commission Lt Panel Board, Tpn 415 Volts, 50 Hz, Indoor Cubical Type Floor Mounted Cpri Approved Factory Made, Double Doordust And Vermin Proofip-54, Fabricatedout Of Crca Sheet Not Less Than 2 Mm Thickwith 2 Mm Thick For Internal Compartment Duly Powder Coated Fixed On Angle Iron Pedestalmade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Led Indicator Lampryb With Switchgears And The Panel Board Shall Be Provided With Proper Ventillation Including Suitable Size Of Cable Alley Al Bus Bar Suitable For Carrying Of Current600 Amps With Suitable Connections From Mccb & Out Going To Main Bus Bar Shall Be Carried Out With Tpn Al Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Aluminium Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator Including Necessary Pcc Foundation Of Minimum 0.200 M Height Positioned And Fixed With Suitable Nut, Bolts, Washers Etc To The Mc Pedestal All As Specified And Directed Comprising Of The Following :- Incoming :- ( A ) Mccb 400 Amps4 Pole 50 Hz 415 V With Thermal Magnectic Release Having Rupturing Capacity 50 Ka - 1 Nos ( B ) Lcd Multifunction Meter - 01 No ( C ) Cts 400 / 5 A- Set Of 3 ( D ) Phase Indicator Lamps ( Ryb ) -Set Of 3 ( E ) 600 Amps Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Incl Insulators, Sleeves Etc 114 Item No 18.79 Cont..... Outgoing :- ( A ) Mccb 320 Amps 3 Pole 50 Hz 415 V With Thermal Magnectic Release Having Rupturing Capacity 50 Ka - 1 No. ( B ) Mccb 63 Amps 3 Pole 50 Hz 415 V With Thermal Magnectic Release Having Rupturing Capacity 50 Ka -1 No ( C ) Mccb 32 Amps 4 Pole 50 Hz 415 V With Thermal Magnectic Release Having Rupturing Capacity 16 Ka - 1 No ( D ) Mcb 16 Amps Spn, 10 Ka - 1 No ( E ) Fully Automatic Star-Delta Starter Suitable For 170 Bhp Fire Pump - 1 No ( F ) Fully Automatic Star-Delta Starter Suitable For 30 Bhpswt Pump - 1 No ( G ) Dol Starter Suitable For 7.50 Bhp Jockey Pump - 1 No 115 Supply, Install, Test And Commission Lt Panel Board, Tpn 415 Volts, 50 Hz, Indoor Cubical Type Floor Mounted Cpri Approved Factory Made, Double Doordust And Vermin Proofip-54, Fabricatedout Of Crca Sheet Not Less Than 2 Mm Thickwith 2 Mm Thick For Internal Compartment Duly Powder Coated Fixed On Angle Iron Pedestalmade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Led Indicator Lampryb With Switchgears And The Panel Board Shall Be Provided With Proper Ventillation Including Suitable Size Of Cable Alley Aluminium Bus Bar Suitable For Carrying Of Current250 Amps With Suitable Connections From Mccb & Out Going To Main Bus Bar Shall Be Carried Out With Tpn Aluminium Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Aluminium Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator Including Necessary Pcc Foundation Of Minimum 0.200 M Height Positioned And Fixed With Suitable Nut, Bolts, Washers Etc To The Mc Pedestal All As Specified And Directed Comprising Of The Following :- Incoming : - ( A ) Mccb 160 Amps 4 Pole 50 Hz 415 V With Thermal Magnectic Release Having Rupturing Capacity 36 Ka - 1 Nos ( B ) Lcd Multifunction Meter - 01 No ( C ) Cts 200 / 5 A- Set Of 3 ( D ) Phase Indicator Lamps ( Ryb ) -Set Of 3 ( E ) 250 Amps Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Incl Insulators, Sleeves Etc ( G ) 125 A, 415 V Manual Change Over, Open Execution -01 Nooutgoing :- ( A ) Mccb 100 Amps 3 Pole 50 Hz 415 V With Thermal Magnectic Release20-25 A Having Rupturing Capacity 25 Ka -4 Nos ( B ) Mccb 32 Amps 4 Pole 50 Hz 415 V With Thermal Magnectic Release Having Rupturing Capacity 16 Ka - 1 No ( C ) Mcb 16 Amps Spn, 10 Ka - 1 No ( D ) Dol Starter Suitable For 10 Bhppumps - 4 Nos 116 Supply, Install, Test And Commission Lt Feeder Pillar Box, Tpn 415 Volts, 50 Hz, Out Door Cubical Type Floor Mounted Cpri Approved Factory Made, Double Doordust And Vermin Proofip-54, Fabricatedout Of Crca Sheet Not Less Than 3.15 Mm Thickwith 2Mm Thick For Internal Compartment Duly Powder Coated Fixed On Angle Iron Pedestalmade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Led Indicator Lampryb With Switch And Fuse And The Panel Board Shall Be Provided With Proper Ventillation Including Suitable Size Of Cable Alley Copper Bus Bar Suitable For Carrying Of Current200 Amps With Suitable Connections From Mccb Out Going To Main Bus Bar Shall Be Carried Out With Tpn Copper Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Copper Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator Including Necessary Pcc Foundation Of Minimum 0.35 M Height Positioned And Fixed With Suitable Nut, Bolts, Washers Etc To The Mc Pedestal All As Specified And Directed Comprising Of The Following :- Incoming :- ( A ) 125A, Mccb, 4P, 100-125 A Relay, 36 Ka -01 No ( B ) Lcd Multifunction Meter - 01 No ( C ) Cts 150 / 5 A- Set Of 3 ( D ) Phase Indicator Lamps ( Ryb ) -Set Of 3 ( E ) 200 Amps Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Incl Insulators, Sleeves Etc Outgoing :- ( A ) 100A, Mccb, 4P, 50-63 A Relay, 25 Ka -01 No ( B ) 100A, Mccb, 4P, 25-32 A Relay, 25 Ka - 01 No ( C ) 20A Dp Mcb, C Curve 10 Ka -01 No ( D ) 16A Fp Mcb, C Curve 10 Ka -04 No 117 Supply, Install, Test And Commission Lt Feeder Pillar Box, Tpn 415 Volts, 50 Hz, Out Door Cubical Type Floor Mounted Cpri Approved Factory Made, Double Doordust And Vermin Proofip-54, Fabricatedout Of Crca Sheet Not Less Than 3.15 Mm Thickwith 2Mm Thick For Internal Compartment Duly Powder Coated Fixed On Angle Iron Pedestalmade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Led Indicator Lampryb With Switch And Fuse And The Panel Board Shall Be Provided With Proper Ventillation Including Suitable Size Of Cable Alley Copper Bus Bar Suitable For Carrying Of Current300 Amps With Suitable Connections From Mccb Out Going To Main Bus Bar Shall Be Carried Out With Tpn Copper Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Copper Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator Including Necessary Pcc Foundation Of Minimum 0.35 M Height Positioned And Fixed With Suitable Nut, Bolts, Washers Etc To The Mc Pedestal All As Specified And Directed Comprising Of The Following :-Incoming :- ( A ) 125A, Mccb, 4P, 100-125 A Relay, 25 Ka -01 No ( B ) Lcd Multifunction Meter - 01 No ( C ) Cts 200 / 5 A- Set Of 3 ( D ) Phase Indicator Lamps ( Ryb ) -Set Of 3 ( E ) 300 Amps Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Incl Insulators, Sleeves Etc Outgoing :- ( A ) 100A, Mccb, 4P, 50-63 A Relay, 25 Ka -01 No ( B ) 16A Fp Mcb, C Curve 10 Ka - 08 Nos ( C ) 16A Dp Mcb, C Curve 10 Ka - 01 No 118 Supply, Install, Test And Commission Lt Feeder Pillar Box, Tpn 415 Volts, 50 Hz, Out Door Cubical Type Floor Mounted Cpri Approved Factory Made, Double Doordust And Vermin Proofip-54, Fabricatedout Of Crca Sheet Not Less Than 3.15 Mm Thickwith 2Mm Thick For Internal Compartment Duly Powder Coated Fixed On Angle Iron Pedestalmade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Led Indicator Lampryb With Switch And Fuse And The Panel Board Shall Be Provided With Proper Ventillation Including Suitable Size Of Cable Alley Copper Bus Bar Suitable For Carrying Of Current300 Amps With Suitable Connections From Mccb Out Going To Main Bus Bar Shall Be Carried Out With Tpn Copper Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Copper Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator Including Necessary Pcc Foundation Of Minimum 0.35 M Height Positioned And Fixed With Suitable Nut, Bolts, Washers Etc To The Mc Pedestal All As Specified And Directed Comprising Of The Following :-Incoming :- ( A ) 100A, Mccb, 4P, 50-63 A Relay, 25 Ka -01 No ( B ) Lcd Multifunction Meter - 01 No ( C ) Cts 100 / 5 A- Set Of 3 ( D ) Phase Indicator Lamps ( Ryb ) -Set Of 3 ( E ) 300 Amps Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Incl Insulators, Sleeves Etcoutgoing :- ( A ) 10A Fp Mcb, C Curve 10 Ka - 14 Nos ( B ) 10A Dp Mcb, C Curve 10 Ka - 01 No 119 Supply, Install, Test And Commission Lt Feeder Pillar Box, Tpn 415 Volts, 50 Hz, Out Door Cubical Type Floor Mounted Cpri Approved Factory Made, Double Doordust And Vermin Proofip-54, Fabricatedout Of Crca Sheet Not Less Than 3.15 Mm Thickwith 2Mm Thick For Internal Compartment Duly Powder Coated Fixed On Angle Iron Pedestalmade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Led Indicator Lampryb With Switch And Fuse And The Panel Board Shall Be Provided With Proper Ventillation Including Suitable Size Of Cable Alley Copper Bus Bar Suitable For Carrying Of Current300 Amps With Suitable Connections From Mccb Out Going To Main Bus Bar Shall Be Carried Out With Tpn Copper Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Copper Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator Including Necessary Pcc Foundation Of Minimum 0.35 M Height Positioned And Fixed With Suitable Nut, Bolts, Washers Etc To The Mc Pedestal All As Specified And Directed Comprising Of The Following :- Incoming :- ( A ) 100A, Mccb, 4P, 25-32 A Relay, 25 Ka -01 No ( B ) Lcd Multifunction Meter - 01 No ( C ) Cts 100 / 5 A- Set Of 3 ( D ) Phase Indicator Lamps ( Ryb ) -Set Of 3 ( E ) 300 Amps Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Including Insulators, Sleeves Etc Outgoing :- ( A ) 10A Fp Mcb, C Curve10 Ka - 06 Nos ( B ) 10A Dp Mcb, C Curve 10 Ka - 01 No 120 Supply, Install, Test And Commission Lt Feeder Pillar Box, Tpn 415 Volts, 50 Hz, Out Door Cubical Type Floor Mounted Cpri Approved Factory Made, Double Doordust And Vermin Proofip-54, Fabricatedout Of Crca Sheet Not Less Than 3.15 Mm Thickwith 2Mm Thick For Internal Compartment Duly Powder Coated Fixed On Angle Iron Pedestalmade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Led Indicator Lampryb With Switch And Fuse And The Panel Board Shall Be Provided With Proper Ventillation Including Suitable Size Of Cable Alley Copper Bus Bar Suitable For Carrying Of Current300 Amps With Suitable Connections From Mccb Out Going To Main Bus Bar Shall Be Carried Out With Tpn Copper Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Copper Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator Including Necessary Pcc Foundation Of Minimum 0.35 M Height Positioned And Fixed With Suitable Nut, Bolts, Washers Etc To The Mc Pedestal All As Specified And Directed Comprising Of The Following :- Incoming :- ( A ) 100A, Mccb, 4P, 32-40 A Relay, 25 Ka -01 No ( B ) Lcd Multifunction Meter - 01 No ( C ) Cts 100 / 5 A- Set Of 3 ( D ) Phase Indicator Lamps ( Ryb ) -Set Of 3 ( E ) 300 Amps Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Incl Insulators, Sleeves Etcoutgoing :- ( A ) 100A, Mccb, 4P, 20-25 A Relay, 25 Ka -01 No ( B ) 16A Fp Mcb, C Curve 10 Ka - 04 Nos ( C ) 10A Dp Mcb, C Curve 10 Ka - 01 No 121 Supply, Install, Test And Commission Lt Feeder Pillar Box, Tpn 415 Volts, 50 Hz, Out Door Cubical Type Floor Mounted Cpri Approved Factory Made, Double Doordust And Vermin Proofip-54, Fabricatedout Of Crca Sheet Not Less Than 3.15 Mm Thickwith 2Mm Thick For Internal Compartment Duly Powder Coated Fixed On Angle Iron Pedestalmade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Led Indicator Lampryb With Switch And Fuse And The Panel Board Shall Be Provided With Proper Ventillation Including Suitable Size Of Cable Alley Copper Bus Bar Suitable For Carrying Of Current300 Amps With Suitable Connections From Mccb Out Going To Main Bus Bar Shall Be Carried Out With Tpn Copper Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Copper Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator Including Necessary Pcc Foundation Of Minimum 0.35 M Height Positioned And Fixed With Suitable Nut, Bolts, Washers Etc To The Mc Pedestal All As Specified And Directed Comprising Of The Following :-Incoming :- ( A ) 100A, Mccb, 4P, 20-25 A Relay, 25 Ka -01 No ( B ) Lcd Multifunction Meter - 01 No ( C ) Cts 100 / 5 A- Set Of 3 ( D ) Phase Indicator Lamps ( Ryb ) -Set Of 3 ( E ) 300 Amps Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Incl Insulators, Sleeves Etc Outgoing :- ( A ) 16A Fp Mcb, C Curve 10 Ka - 04 Nos ( B ) 20A Dp Mcb, C Curve 10 Ka - 01 No 122 Supply, Install, Test And Commission Lt Feeder Pillar Box, Tpn 415 Volts, 50 Hz, Out Door Cubical Type Floor Mounted Cpri Approved Factory Made, Double Doordust And Vermin Proofip-54, Fabricatedout Of Crca Sheet Not Less Than 3.15 Mm Thickwith 2Mm Thick For Internal Compartment Duly Powder Coated Fixed On Angle Iron Pedestalmade Out Of 50X50x6 Mm With Cable Chamberfor Individual Feeders For Incommingand Outgoing Connections, One Set Of Led Indicator Lampryb With Switch And Fuse And The Panel Board Shall Be Provided With Proper Ventillation Including Suitable Size Of Cable Alley Copper Bus Bar Suitable For Carrying Of Current300 Amps With Suitable Connections From Mccb Out Going To Main Bus Bar Shall Be Carried Out With Tpn Copper Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Copper Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator Including Necessary Pcc Foundation Of Minimum 0.35 M Height Positioned And Fixed With Suitable Nut, Bolts, Washers Etc To The Mc Pedestal All As Specified And Directed Comprising Of The Following :- Incoming :- ( A ) 100A, Mccb, 4P, 25-32 A Relay, 25 Ka -01 No ( B ) Lcd Multifunction Meter - 01 No ( C ) Cts 100 / 5 A- Set Of 3 ( D ) Phase Indicator Lamps ( Ryb ) -Set Of 3 ( E ) 300 Amps Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Incl Insulators, Sleeves Etc Outgoing :- ( A ) 30A Fp Mcb, C Curve 10 Ka - 04 Nos ( B ) 20A Dp Mcb, C Curve 10 Ka - 01 No 123 Supply And Fix Cable Route Indicator Made Of Rcc ( 1:1:5:3 ) Type Ai Of Size 120 Cm Long, 15X15cm Cross Section At Bottom Tapered To Cross Section 10Cmx10cm At Top Duly Reinforced With 4 Nos 10 Mm Dia Tmt Main Bars And 8 Mm Dia Tmt Bar As Stirrups @ 150 Mm C / C And Engraved With Lt Mes To Be Installed At Different Places Complete All As Specified And As Directed. 124 S&F Thermo-Plastic Cable Junction Box Weather Proof For Street Light Of Size 205X255x112 Mm Inclusive Tpn Connectors Terminals For Cable Connection With Ip 66 / 67 Protection Of Make: Hensel, Cat No Kf 1600C Or Equivalent In Other Approved Makes Incuding One Mcb Single Pole 1 Amp, 240 Volt, 10 Ka C Curve Mounted On Din Rail And Connecting All The Incoming And Outing Cable Terminals With Lugscomplete All As Specified And As Directed. 125 M&L For Wiring With 2X1.5 Sqmm Plus 1X1.5 Sqmm Earth Wire ( Nominal Cross-Sectional Area ) Frls Pvc Insulated And Unsheathed 1100 Volts Grade Multistranded Copper Conductor Cable Drawn Through And Incl Steel Conduit Of 20 Mm Dia Medium Grade From Street Light Junction / Terminal Box To Street Light Fitting Including Clamps For Fixing The Pvc Conduit With Street Light Polescomplete All As Specified And As Directed. 126 S&F Lithium Based Energy Efficient Integrated Solar Street Light 32 Watt Including Ms Pole Duly Painted With Alluminium Paint 6 Mtr Long 63 Mm Dia In Single Frp Body Encases Solar Pv Panel 64 / 66Wp Monocrystalline , Lithium Battery 11.1 / 12.8V, 33.0Ah With Inbuilt Bms, High Brightness W-Led ( 160-180 Lm / Watt ) Lamp With Reflector, Cri >70, Color Temperature 6500K, Microcontroller Based Charge Controller Cum Driver, Automatic Dimming Function With Pir Motion Sensor, Dusk To Dawn Operation, Working Temperature: ( - ) 10C To ( + ) 55C, Weight: 18–20 Kg, With Adjustable Ms Clamp Suitable For Pole / Wall Mounting. Protections: Short Circuit, Overload, Reverse Polarity And Battery Protectionscomplete All As Specified And As Directed. 127 S&F In Replacement Nature Switch In Enclosure Made Out Of Uv Stablized, Fr Grade Special Moulding Compound, Rust Proof, Electric Shok Proof, Vermine Proof Outdoor Pole Mountable With Mounting Bracket Made Out Of Fi And Nut, Bolts, Washers Including Cable Glands, Openable Door With Lock Comprising With Power Contactor Three Phase Rating, 32 Amps 4 Pole-01 No, Mcb Sp 20 Amps-03 Nos For Max Load 5Kw Including Taking Down Existing Nature Switch, Ip 66 Enclosurecomplete All As Specified And As Directed. 128 Supply And Fix Led Flood Light 140 W Ip 65 Complete All As Directed. 129 Supply And Fix High Intensity Long Range Manual Revolving Search Light, 250 Watt Mh Type With Adjustable Focusing Arrangement And Suitable For Rotating In Both Axis Complete All As Specified And As Directed. 130 Supply And Fix Time Switches Astro Type ( Having Longitude And Latitude Of Indian Cities In Memory ) 250 V Single Phase Of 20 Amp Rating With Contactor Fitted Inside Steel Enclosure Complete All As Specified And As Directed. 131 Supply, Installation, Testing And Commissioning Of Silent Type Diesel Engine Driven Generating Set Isi Marked Water Cooled Type, 415 Volts, 3 Phase 4 Wire ( Engine As Per Is: 10001 / 10002 And Alternator As Per Is: 13364 ) Complete With Foundation As Per ManufacturerS Recommendation, Standard Amf Panel With Necessary Protection And Meters Including Sound Proof Canopy Of Capacity 125 Kvaincluding The Following: - ( A ) Enginediesel Engine Prime Mover Of Suitable Bhp To Drive 100 Kva Alternator With The Following: - ( I ) Fuel Level Indicator ( Ii ) Fuel Tank Of Suitable Capacity For Storing Minimum 8 Hrs Consumption Capacity At 75% Load. ( Iii ) Fuel Inlet Arrangement From Outside The Acoustic Enclosure With Locking Arrangement. ( Iv ) Robust, Ms Base Frame With Anti Vibration Damper Pads ( V ) Continuous 10% Overload Capacity In Every 12 Hrs Running. ( Vi ) Self Starting With And Including Suitable Maintenance Free Battery Of Suitable Ah Rating As Per Oem Including Charging Circuit. ( Vii ) Mechanical Or Electronic Governor As Per Oem. ( B ) Alternator100 Kva At 0.8 Pf ( Lag ) , 415 Volt, 3 Phase, 4 Wire, 50 Hz, 1500 Rpm Copper Wound With The Following: - ( I ) Self Regulated Brushless Self Excitation. ( Ii ) Automatic Voltage Regulator With Band Of Voltage Regulation: + 2.5% Of Rated Voltage. ( C ) Control Panelfactory Fabricated Free Standing Of Suitable Size Copper Bus Bar With The Following: - ( I ) Mccb 4 Pole, 415 Volt, 3 Phase Of 160 Amps, 16 Ka As Per Oem. ( Ii ) Internal Wiring With Suitable Size Copper Conductor ( Iii ) Start And Stop Push Button ( Iv ) Digital Voltmeter With Selector Switch ( V ) Digital Frequency Meter ( Vi ) Digital Ammeter With 3 Nos Ct And Selector Switch ( Vii ) Digital Power Factor Meter ( Viii ) Three Phase Energy Meter ( Ix ) Tripping Arrangement With Hooter For High Engine Temp, Low Lub Oil Pressure, High Lub Oil Temp, Low And High Engine Speed Etc As Per Manufacturers Design. ( D ) Acoustic Enclosure It Should Be Compact, Modular Construction And Approved By Arai ( Nodal Agency Of Cpcb ) With The Following: - ( I ) Overall Noise Level Less Than 75 Db Measured At 1 Mtr Distance In Free Field Condition. ( Ii ) Inside Illumination Provide With 2 Nos 1 X 9 Watt Led Light Fitting Or As Per Manufacturers Design.Note: - ( I ) The Cost Of Foundation For Installing The Dg Setas Per Manufacturers Recommendation And Is Deemed To Be Included In The Quoted Rate ( Ii ) First Filling Of Fuel ( Dhpp ( N ) For 12 Hours Load Test Purpose Shall Be Provided And Cost Deemed To Be Included In The Quoted Rate. ( Ii ) Any Accessories Not Mentioned But Included In Manufacturers Standard Modules Are Deemed To Be Included In The Quoted Rate. ] 132 Supply, Installation, Testing And Commissioning Of Silent Type Diesel Engine Driven Generating Set Isi Marked Water Cooled Type, 415 Volts, 3 Phase 4 Wire ( Engine As Per Is: 10001 / 10002 And Alternator As Per Is: 13364 ) Complete With Foundation As Per ManufacturerS Recommendation, Standard Amf Panel With Necessary Protection And Meters Including Sound Proof Canopy Of Capacity 50 Kvaincluding The Following: - ( A ) Enginediesel Engine Prime Mover Of Suitable Bhp To Drive 100 Kva Alternator With The Following: - ( I ) Fuel Level Indicator ( Ii ) Fuel Tank Of Suitable Capacity For Storing Minimum 8 Hrs Consumption Capacity At 75% Load. ( Iii ) Fuel Inlet Arrangement From Outside The Acoustic Enclosure With Locking Arrangement. ( Iv ) Robust, Ms Base Frame With Anti Vibration Damper Pads ( V ) Continuous 10% Overload Capacity In Every 12 Hrs Running. ( Vi ) Self Starting With And Including Suitable Maintenance Free Battery Of Suitable Ah Rating As Per Oem Including Charging Circuit. ( Vii ) Mechanical Or Electronic Governor As Per Oem. ( B ) Alternator100 Kva At 0.8 Pf ( Lag ) , 415 Volt, 3 Phase, 4 Wire, 50 Hz, 1500 Rpm Copper Wound With The Following: - ( I ) Self Regulated Brushless Self Excitation. ( Ii ) Automatic Voltage Regulator With Band Of Voltage Regulation: + 2.5% Of Rated Voltage. ( C ) Control Panelfactory Fabricated Free Standing Of Suitable Size Copper Bus Bar With The Following: - ( I ) Mccb 4 Pole, 415 Volt, 3 Phase Of 160 Amps, 16 Ka As Per Oem. ( Ii ) Internal Wiring With Suitable Size Copper Conductor ( Iii ) Start And Stop Push Button ( Iv ) Digital Voltmeter With Selector Switch ( V ) Digital Frequency Meter ( Vi ) Digital Ammeter With 3 Nos Ct And Selector Switch ( Vii ) Digital Power Factor Meter ( Viii ) Three Phase Energy Meter ( Ix ) Tripping Arrangement With Hooter For High Engine Temp, Low Lub Oil Pressure, High Lub Oil Temp, Low And High Engine Speed Etc As Per Manufacturers Design. ( D ) Acoustic Enclosure It Should Be Compact, Modular Construction And Approved By Arai ( Nodal Agency Of Cpcb ) With The Following: - ( I ) Overall Noise Level Less Than 75 Db Measured At 1 Mtr Distance In Free Field Condition. ( Ii ) Inside Illumination Provide With 2 Nos 1 X 9 Watt Led Light Fitting Or As Per Manufacturers Design.Note: - ( I ) The Cost Of Foundation For Installing The Dg Setas Per Manufacturers Recommendation And Is Deemed To Be Included In The Quoted Rate ( Ii ) First Filling Of Fuel ( Dhpp ( N ) For 12 Hours Load Test Purpose Shall Be Provided And Cost Deemed To Be Included In The Quoted Rate. ( Ii ) Any Accessories Not Mentioned But Included In Manufacturers Standard Modules Are Deemed To Be Included In The Quoted Rate. ] 133 M & L For Concealed Point Wiring With 1.5 Sqmm ( Nominal Cross-Sectional Area ) Frlsh Pvc Insulated & Unsheathed 1100 Volts Grade Multi Stranded Copper Conductor Single Core Cable Drawn Through And Including Non-Metallic Rigid Pvc Conduit Ofadequate Size With All Fittings And Accessories Including Mild Steel Terminal Boxes With Laminated Sheet For Mounting Switches, Socket, Regulators Etc Complete Including Frlsh Pvc Insulated & Unsheathed Single Core Multistranded Copper Conductor Cable Of Size 1.5 Sqmm Green In Colour As Earth Continuity Conductor Connected To Common Earthdolly Forone Light Point Controlled By One, One Way Switch Complete All As Specified And Directed 134 M & L For Concealed Point Wiring With 1.5 Sqmm ( Nominal Cross-Sectional Area ) Frlsh Pvc Insulated & Unsheathed 1100 Volts Grade Multi Stranded Copper Conductor Single Core Cable Drawn Through And Including Non-Metallic Rigid Pvc Conduit Ofadequate Size With All Fittings And Accessories Including Mild Steel Terminal Boxes With Laminated Sheet For Mounting Switches, Socket, Regulators Etc Complete Including Frlsh Pvc Insulated & Unsheathed Single Core Multistranded Copper Conductor Cable Of Size 1.5 Sqmm Green In Colour As Earth Continuity Conductor Connected To Common Earthdolly Forone Socket Outletpoint 6Amps On Same Board Complete All As Specified And Directed 135 M & L For Concealed Point Wiring With 1.5 Sqmm ( Nominal Cross-Sectional Area ) Frlsh Pvc Insulated & Unsheathed 1100 Volts Grade Multi Stranded Copper Conductor Single Core Cable Drawn Through And Including Non-Metallic Rigid Pvc Conduit Ofadequate Size With All Fittings And Accessories Including Mild Steel Terminal Boxes With Laminated Sheet For Mounting Switches, Socket, Regulators Etc Complete Including Frlsh Pvc Insulated & Unsheathed Single Core Multistranded Copper Conductor Cable Of Size 1.5 Sqmm Green In Colour As Earth Continuity Conductor Connected To Common Earthdolly Forone Socket Outletpoint 6Amps On Independent Board Complete All As Specified And Directed 136 M & L For Concealed Point Wiring With 1.5 Sqmm ( Nominal Cross-Sectional Area ) Frlsh Pvc Insulated & Unsheathed 1100 Volts Grade Multi Stranded Copper Conductor Single Core Cable Drawn Through And Including Non-Metallic Rigid Pvc Conduit Ofadequate Size With All Fittings And Accessories Including Mild Steel Terminal Boxes With Laminated Sheet For Mounting Switches, Socket, Regulators Etc Complete Including Frlsh Pvc Insulated & Unsheathed Single Core Multistranded Copper Conductor Cable Of Size 1.5 Sqmm Green In Colour As Earth Continuity Conductor Connected To Common Earthdolly For One Light Point Controlled By One, Two Way Switch Complete All As Specified And Directed 137 M & L For Concealed Point Wiring With 4 Sqmm ( Nominal Cross-Sectional Area ) Frlsh Pvc Insulated & Unsheathed 1100 Volts Grade Multi Stranded Copper Conductor Single Core Cable Drawn Through And Including Non-Metallic Rigid Pvc Conduit Ofadequate Size With All Fittings And Accessories Including Mild Steel Terminal Boxes With Laminated Sheet For Mounting Switches & Socket, Including One Run Offrlsh Pvc Insulated & Unsheathed Single Core Multistranded Copper Conductor Cable Of Size 4 Sqmm Green In Colour As Earth Continuity Conductor Connected To Common Earthdolly For One 16 Amp Socket Outlet On Independent Board Complete All As Specified And Directed. 138 S&F Switch Piano Flush Buton Single Pole Two Way 5 / 6 Amps Isi Marked Complete All As Specified And As Directed. 139 S&F Switch Socket Combination Outlet 2 In 1, 5 Pin, 5 Amps Flush Type, 230 V ( Isi Marked ) Complete All As Specified. 140 S&Fswitch Socket Combination Outlet 2 In 1, 6 Pin, 6 / 16 Amps Flush Type, 230 V ( Isi Marked ) Complete All As Specified. 141 M & L For Sub Main Wiring With Two Run Of 6.0 Sqmm ( Nominal Cross-Sectional Area ) Frlsh Pvc Insulated & Unsheathed 1100 Volts Grade Multistranded Copper Conductor Single Core Cable Drawn Through And Includingpvc Conduit Pipe Medium Grade Of Adequates Size And Fittings And Accessories Concealed In Walls, Floors And Ceilings Complete Including One Run Of Frlsh Pvc Insulated & Unsheathed Single Core Multistranded Copper Conductor Cable Of Size 6.0 Sqmm Green In Colour As Earth Continuity Conductor Connected To Common Earth And Earth Dolly Complete All As Specified And Directed.Note: Two Single Core Cable And One No. Earth Wire And One Run Of Conduit Shall Be Measured Together As One Length 142 Supply And Fixing Led Lights Fitting 1X 10 W, 220V, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed. 143 Supply And Fixing Led Lamp 9W B-22 Cool Daylight Suitable For Bayonet Cap Type Holder Complete All As Specified And Directed. 144 Supply Of Precast Rcc Dunnage Block ( Size - 300 X 300 X 300 Mm ) Including Reinforcements, All As Specified And Shown On Drawings. 145 Providing And Fixing Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 M Openable Length ( Total Length 90 M ) , Having 50 Nos Rounds Per 6 Meter Lenght, Upto 3 M Height Of Wall With Existing Angle Iron Y Shaped Placed 2.4 M Or 3.0 M Apart And With 9 Horizontal R.B.T. Reinforcedbarbedwire , Stud Tied With G.I. Staples And G.I. Clips To Retainhorizontal , Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron , Complete As Per Direction Ofengr -In-Charge, With Reinforced Barbed Tape ( R.B.T. ) / Spring Core ( 2.5 Mm Thick ) Wire Of Tensile Strenght Of 165 Kg / Sqmm With Tape ( 0.52 Mm Thick ) And Weight 43.478Gm / Metre Complete All As Specified And Directed. Note:Cost Of M.S. Angle, C.C Blocks Shall Be Measured And Paid Separately 146 Construction Of Steel Gate With Rcc Pillar 5.50 M Wide As Per Drg No Cesz / 2015 / Td / 34, Sht No 1 / 1And As Specified 147 Construction Of Wicket Gate 1.20 M Wide As Per Drg No Cesz / 2015 / Td / 34, Sht No 1 / 1And As Specified 148 M & L For Point Wiring With 1.5 Sqmm ( Nominal Cross-Sectional Area ) Frlsh Pvc Insulated & Unsheathed 1100 Volts Grade Multi Stranded Copper Conductor Single Core Cable Drawn Through And Including Stove Enamelled Steel Conduit Ofadequate Size With All Fittings And Accessories Including Mild Steel Terminal Boxes With Laminated Sheet For Mounting Switches, Socket, Regulators Etc Complete Including Frlsh Pvc Insulated & Unsheathed Single Core Multistranded Copper Conductor Cable Of Size 1.5 Sqmm Green In Colour As Earth Continuity Conductor Connected To Common Earth And Earth Dolly For One Light Point Controlled By One, One Way Switch Complete All As Specified And Directed. 149 M & L For Point Wiring With 4.0 Sqmm ( Nominal Cross-Sectional Area ) Frlsh Pvc Insulated & Unsheathed 1100 Volts Grade Multi Stranded Copper Conductor Single Core Cable Drawn Through And Including Stove Enamelled Steel Conduit Ofadequate Size With All Fittings And Accessories Including Mild Steel Terminal Boxes With Laminated Sheet For Mounting Switches & Socket, Including One Run Offrlsh Pvc Insulated & Unsheathed Single Core Multistranded Copper Conductor Cable Of Size 4.0 Sqmm Green In Colour As Earth Continuity Conductor Connected To Common Earth And Earth Dolly For One 16 Amp Socket Outlet On Independent Board Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Jan-2023 Date corrigendum 1 Date 19-01-2023
2 13-Jan-2023 Corrigendum 2 Date 31-01-2023
3 25-Jan-2023 Dates Date 10-02-2023
4 25-Jan-2023 Revised BOQ, Tender pages and drawings BOQ 10-02-2023
5 01-Feb-2023 Re revised BOQ and tender pages BOQ 10-02-2023
6 01-Feb-2023 New Dates Date 11-02-2023
7 02-Feb-2023 BOQ and tender pages BOQ 13-02-2023
8 04-Feb-2023 CORRIGENDUM 6 Other 13-02-2023
9 07-Feb-2023 Soil inv report Other 13-02-2023
10 07-Feb-2023 Soil Inv report Other 13-02-2023
11 07-Feb-2023 Soil Inv Report Other 13-02-2023
12 13-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-02-2023

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK:PROVN OF FASF FOR SIGAR MIL STATION AT SIGAR UNDER GE 872 EWS
Sl. No. Item Description
1Note:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum / amendments and General conditions of contracts before entry/quoting the rates.
2Lumpsum price workedout by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I(A)
3Schedule "A" Part-I(B); design and building works Note :- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs. 0.00" under Col - 5 signifies this fact only.
4Design and construction ofgarrage building for "B" veh, Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V, complete all as specified and shown on drawings No. CESZ/LKB-SIG/2022/AR-39 Dt-10.11.22 SH 1/2 to 2/2 and Drg No. CESZ/LKB-SIG/2022/SOF-55 Dt-10.11.22 SH 3/4
5Design and construction ofSub-fire station building ,Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V,complete all as specified and shown on drawings NoCESZ/LKB-SIG/2022/AR-40 Dt-10.11.22 SH 1/3 to 3/3 and Drg No. CESZ/LKB-SIG/2022/SOF-55 Dt-10.11.22 SH 3/4
6Design and constructionSingle living Accnfor 03Havs and 46 ORs , Double Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V,complete all as specified and shown on drawings No CESZ/LKB-SIG/2022/AR-44 Dt-10.11.22 SH 1/6 to 6/6
7Design and construction of Cook house and dining hall for 49 Pers, Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V,complete all as specified and shown on drawings NoCESZ/LKB-SIG/2022/AR-45 Dt-10.11.22 SH 1/2 to 2/2
8Design and construction of200000 gallons RCCUG Sump in RCC construction with permanent specification including , sesmic consideration of Zone V, etc.with permanent specification complete all as specified and shown on drawings.
9Design and construction of Pump house building Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V,complete all as specified and shown on drawings No.CESZ/LKB-SIG/2022/AR-46 Dt-10.11.22 SH 1/2 to 2/2 and Drg No. CESZ/LKB-SIG/2022/SOF-55 Dt-10.11.22 SH 4/4
10Design and construction of Pump house cum chlorination plant. Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V,complete all as specified and shown on drawings No CESZ/LKB-SIG/2022/AR-47 Dt-10.11.22 SH 1/1and Drg No. CESZ/LKB-SIG/2022/SOF-55 Dt-10.11.22 SH 4/4
11Design and construction ofSub Stn building for 11KV, Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V, complete all as specified and shown on drawings No CESZ/LKB-SIG/2022/AR-49 Dt-10.11.22 SH 1/2 to 2/2 and Drg No. CESZ/LKB-SIG/2022/SOF-55 Dt-10.11.22 SH 3/4
12Design and construction of Guard house and ancilllaries & Armoury building, Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V,complete all as specified and shown on drawings No CESZ/LKB-SIG/2022/AR-50 Dt-10.11.22 SH 1/4 to 4/4
13Design and construction of storage cum Drying and Ironing buildingSingle Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V,complete all as specified and shown on drawings NoCESZ/LKB-SIG/2022/AR-52 Dt-10.11.22 SH 1/2 to 2/2
14Design and construction ofMT driver standby and changing room building, Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V,complete all as specified and shown on drawings NoCESZ/LKB-SIG/2022/AR-51 Dt-10.11.22 SH 1/3 to 3/3
15Design and construction of Receipt and issue building, Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V,complete all as specified and shown on drawings NoCESZ/LKB-SIG/2022/AR-55 Dt-10.11.22 SH 1/2 to 2/2
16Design and construction of Pump house for bore well No 2, Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V, complete all as specified and shown on drawings NoCESZ/LKB-SIG/2022/AR-53 Dt-10.11.22 SH 1/1and Drg No. CESZ/LKB-SIG/2022/SOF-55 Dt-10.11.22 SH 4/4
17Design and construction ofJCO Single Living Accn,Single Storey RCC framed construction with permanent specification includingwater proofing treatment to roof, sesmic consideration of Zone V,complete all as specified and shown on drawings No CESZ/LKB-SIG/2022/AR-54 Dt-10.11.22 SH 1/1 and Drg No. CESZ/LKB-SIG/2022/SOF-55 Dt-10.11.22 SH 3/4
18Note for items Sr. No. 2.01 to2.14(except 2.05) -Quoted amount shall be inclusive of cost of following items- (a).Design and construction of buildings/structures (b).Third party vetting from any IITs /NITs. (c) Cost of fitting and fixtures and finishing work as specified in respective drawing listed in list of drawing except items specified in SCH Á"Part-III, IV, IX, X and XVI which shall be measured and paid under respective schedule. Note for item srl No 2.05 design and construction of UG sump including all fittings and fixtures to make it fully functional.
19Lumpsum price worked out by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II.
20Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III.
21Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATIONS as listed in Schedule ‘A’ Part-IV.
22Lumpsum price worked out by the tenderer for ROADS / PATH / CULVERT / HARD STANDING as listed in Schedule ‘A’ Part-V.
23Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI.
24Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII.
25Lumpsum price worked out by the tenderer for BOUNDRY WALL/SECURITY FENCING / GATE as listed in Schedule ‘A’ Part-VIII.
26Lumpsum price worked out by the tenderer for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-IX.
27Lumpsum price worked out by the tenderer for COLLING APPLIANCES as listed in Schedule ‘A’ Part-X.
28Lumpsum price worked out by the tenderer for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-XI.
29Lumpsum price worked out by the tenderer for FIRE ALARM SYSTEM as listed in Schedule ‘A’ Part-XII.
30Lumpsum price worked out by the tenderer for CHEMICAL EARTHING as listed in Schedule ‘A’ Part-XIII.
31Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XIV.
32Lumpsum price worked out by the tenderer for FIRE FIGHTING SYSTEM as listed in Schedule ‘A’ Part-XV.
33Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-XVI.
34Sch "A" Sec-XVIII (Miscellaneous Items)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
35Preparation & submission of soil investigation report in sixupulate by conducting soil investigation after making bore holes 150 mm dia in any type of soil up to max 15.0 m depth or upto the depth of refusal, collecting, disturbed and undisturbed samples, conducting standard penetration test (SPT) at 1.5 mtr interval thereafter or on change of strata and laboratory test like Direct/Triaxial shear test, sieve analysis Grain distribution curves & pattern in bore holes, Type of soil, C value, Bulk density, Natural moisture content, Dry density,Water table, Specific gravity, Atterberg limit, Hydrometer analysis, Liquid & Plastic limit, Swelling Index, void ratio and porosity, unconfined compressure test Evaluation of liquifaction potential IS-1893 Part I -2016.Compilation of Field and Laboratory test results, Preparation of reports, Recommendation for depth of embedment, water table, submission of all report booklets 06 (Six) copies with CD 01 (One) copy including photographs & videography duly indicating the following :- (i) Evaluation of safe bearing capacity of the soil with respect to shear failure test and permissible settlement (Total and Differential) alongwith recommendation about type of foundation and minimum depth offoundation to be adopted for subject work. (ii) Evaluation of liquefaction potential. (iIi)Specific suggestions if any for Soil Treatment if required below foundation /ground floor / roads and type of treatment to be carried out.
36ITEM NO 18.01 CONT... (iv)Bore log diagram duly showing the different layers of strata met alongwith their depths. Note : (i) Each bore hole will be measured upto depth of refusal or 15.00 m whichever is earlier. (ii) Rate includes mobilsation of T&P as per requirement and direction of the Engr-in-Charge. (iii) Rate includes Vetting of geotechnical investigation reportfrom any NIT(National Institute of Technology)/IITs(Indian Institute of Technology) and submit hard copy & soft copy in Six numbers/sets for approval of accepting officer.
37Preparation & submission of soil investigation report in sixupulate by conducting soil investigation with trial pit of size 1.2 x 1.2 x 1.2m after making bore holes 150 mm dia in any type of soil up to max 15.0 m depth or upto the depth of refusal, collecting, disturbed and undisturbed samples, conducting standard penetration test (SPT) at 1.5 mtr interval thereafter or on change of strata and laboratory test like Direct/Triaxial shear test, Grain distribution curves & pattern in bore holes, Type of soil, C value, Bulk density, Natural moisture content, Dry density,Water table, Specific gravity, Atterberg limit, Hydrometer analysis, Liquid & Plastic limit, Swelling Index, Evaluation of liquifaction potential IS-1893 Part I -2016.
38ITEM NO 18.03 CONT.. Compilation of Field and Laboratory test results, Preparation of reports, Recommendation for depth of embedment, water table, submission of all report booklets 06 (Six) copies with CD 01 (One) copy including photographs & videography duly indicating the following :- (i) Evaluation of safe bearing capacity of the soil with respect to shear failure test and permissible settlement (Total and Differential) alongwith recommendation about type of foundation and minimum depth offoundation to be adopted for subject work. (ii) Evaluation of liquefaction potential. (iii) Evaluation of K-value. (iv)Specific suggestions if any for Soil Treatment if required below foundation /ground floor / roads and type of treatment to be carried out. (v)Bore log diagram duly showing the different layers of strata met alongwith their depths. Note : (i) Each bore hole will be measured upto depth of refusal or 15.00 m whichever is earlier. (ii) Rate includes mobilsation of T&P as per requirement and direction of the Engr-in-Charge. (iii) Rate includes Vetting of geotechnical investigation reportfrom any NIT(National Institute of Technology)/IITs(Indian Institute of Technology) and submit hard copy & soft copy in Six numbers/sets for approval of accepting officer.
39Bringing approved earth (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any , transportation ,taxes,etc. for area filling / area development upto MGL level including raising of original ground level upto MGL by approved earth and includingspreading in layers not exc 30cm thick each layer ,watering , compaction with 8 tonne to 12 tonne power roller and finished to required size and shape etc. Notes: (i)Earth required for the item, shall be supplied by contractor, from out side MOD land of any lead, at his own own arrangement. (ii) All cost of procurement of earth including cost of transportation, compaction, royalties, tax etc shall be deemed to be included in the unit rate quoted by the contractor. (iii) With reference to clause 3.6 of MES part-II on serial page No-21 it is clarified that measurement of the above item shall be of finished embankment /traverse of filled earth after consolidation /compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk.
40Material & labor for on site Hume Pipe septic tank for 10 Users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all specified and directed.
41M&L for RCC Septic tank 100 users with upflow filter type designatedto carry sewage and sullage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc, complete with effective depth 1.5 mtr and over all depth of 3 mtr for complete all specified and shown on drawing No CESZ/2020/STD-02 Sheet 1/2 to 2/2
42Construction of Brick Masonry SOAK WELL OF SIZE 1.2 M DIA & 3.00 M DEPTH with all fittings and fixtures complete all as specified and shown on drawing No CESZ/2020/TD/45 sheet 1/2 to 2/2
43Construction of Brick Masonry SOAK WELL OF SIZE 2.40 M DIA & 4.50 M DEPTH with all fittings and fixtures complete all as specified and shown on drawing No. SZ/2020/TD/45 sheet 1/2 to 2/2
44Supply, installation, testing & commissioningofheater water storage type electric geyser (vertical cylindrical type) 25 Litre capacity with BEE 5 star rating (minimum) and metallic body, porcelain enamel glass lined inner tank including fixing arrangement with providing and including suitable capacity flexible cable 3 core with 3-pin plug of 16A capacity maximum 2metre length, PVC Connection pipe of suitable length for Hot and Cold Water, fixing on Walls with and including all necessary fitting material i.e. Mild Steel Bolts (Bolts to be grouted), Nuts, Washers, etc complete all as specified and as directed.
45Supply and fix refrigerator double door, electric driven (single phase), capacity 340 Litres with smart inverter compressor, frost free, multi air flow, anti bacterial gasket, 5 star rating complete all specified and directed.
46Supply and fix refrigerator double door, electric driven (single phase), capacity 360 Litres with smart inverter compressor, frost free, multi air flow, anti bacterial gasket, 5 star rating complete all specified and directed.
47Chemical earthing with copper earth plate 90x60cmx5mm buried directly in gound (earth pit not less than 2.25m deep below normal ground level) with top edge plate not less than 1.5m deep below normal ground level connected to copper earth strip 50x6mm by means of bolts, nuts, check nuts and washers made of glavanized iron,20mm dia GI pipe (med grade) for watering, 15mm dia GI pipe (light grade) for protection of earth lead wire,including necesary earth work in any type of soil, PCC (1:3:6) Type C1 concerete pit, RCC (1:1.5:3) type A1 precast cover (54 x 54 x 5cm) duly reinforced with including 8mm dia TMT bar @ 150mm c/c both ways, one lifting handle made of 8mm dia TMT bar, embebed in precast cover slab complete all as specified and shown in electrical plate No 3 of SSR Part-I including testing on completion.
48Chemical earthing with copper earth plate 30x30cmx3mm buried directly in gound (earth pit not less than 2.25m deep below normal ground level) with top edge plate not less than 1.5m deep below normal ground level connected to copper earth strip 25x3mm by means of bolts, nuts, check nuts and washers made of glavanized iron,20mm dia GI pipe (med grade) for watering, 15mm dia GI pipe (light grade) for protection of earth lead wire,including necesary earth work in any type of soil, PCC (1:3:6) Type C1 concerete pit, RCC (1:1.5:3) type A1 precast cover (54 x 54 x 5cm) duly reinforced with including 8mm dia TMT bar @ 150mm c/c both ways, one lifting handle made of 8mm dia TMT bar, embebed in precast cover slab complete all as specified and shown in electrical plate No 3 of SSR Part-I including testing on completion.
49Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32 x 6mm as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layers complete as shown in electrical plate No. 3 of SSR Part-I all as specified and directed by Engr-in-Charge.
50Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI wire 4mm dia as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layers complete as shown in electrical plate No. 3 of SSR Part-I all as specified and directed by Engr-in-Charge.
51M&L for earthing complete with copper earth plate of size600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to earth lead wire of copper strip of size 20 x 3 mm dia by means of nuts/bolts and washers, check nuts of galvanized iron or steel including 15mm dia GI pipe light grade upto 1.5 mtr below GL for protection pipe, excavation and earth work charcoal dust, common salt, PCC 1:3:6type C-1 chamber with cover and RCC1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm c/c both way with MS handle 12mm dia PGI funnel and wire mesh all as shown in electrical plate No 5 of SSR Part-I connected to ear thing test point all as specified or indicated including testing on completion all as directed by Engr-in-Charge.
52Supply and fix GI strip 32mm x 6mm buried in ground complete all as specified.
53Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electriccables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade. complete all as specified and directed.
54M& L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed. Note : Punned thickness shall be measured and paid.
55Supply and fix Junction box dia 100 x 65 high dust proof dust tight /totally enclosed typecomplete all as specified and directed.
56Supply and fix epoxy powder coated Flameproof/Weatherproof lighting distribution panel having IP66 protection enclosure of Cast Aluminum alloy material. The Distribution Board should be SPN 8 way including 01 No. Incommer MCB 2 pole 32 Amps "C" type and 5 No. outgoing MCBs 6 Amps & 01 No 10 Ams MCB with complete internal common bus-bar &wiring up to terminals all as directed.
57Supply and Fixing of CIMFR certified Flameproof cum Waterproof light fitting of 60W,recommendedfor Gas/Vapour group of IIA & IIB and Zone 1 & 2 IP65 protection IP65 protection,Cast Aluminum alloy material and Heat and Impact resistance toughen "A" clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size drawn in flexible steel conduit complete all as specified and as directed.
58Drilling trial bore hole by ODEX full casing method through any kind of soil, boulder rock for a bore of 200mm dia tube well as required as per site condition upto 200 Mtr depth as per IS-2800 including disposal of soil from the site complete .. (Note: This item will be considered for payment if borewell is not successfull at site as directed by the Engr-in-charge)
59Drilling and development of trial bore hole by ODEX full casing method through any kind of soil, boulder rock for a bore of 200mm dia tube well as required as per site condition upto 60 m from ground level as per IS-2800 including disposal of soil from the site completeall as specified and directed by Engr-in-Charge
60Drilling and development of trial bore hole by ODEX full casing method through any kind of soil, boulder rock for a bore of 200mm dia tube well as required as per site condition exc 60 mtr an n.exc 120mtr from ground level as per IS-2800 including disposal of soil from the site completeall as specified and directed by Engr-in-Charge
61Drilling and development of trial bore hole by ODEX full casing method through any kind of soil, boulder rock for a bore of 200mm dia tube well as required as per site condition exc 120 mtr an n.exc 150mtr from ground level as per IS-2800 including disposal of soil from the site completeall as specified and directed by Engr-in-Charge
62Assembling, lowering and fixing into bore holes, 200 mm bore, mild steel ERW (ISI marked), casing pipe having wall thickness 6mm as per IS-4270-2001 (Steel tube or water well), heavy grade, plain end, blank jointed with collar through electric resistance of high frequency induction welding for increasing of length of pipe including necessary fittings and providing two coats of black bituminous paint (for drinking purpose) internally and externallycompleteall as specified and directed by Engr-in-Charge
63Assembling, lowering and fixing into bore holes, 150 mm bore, mild steel ERW (ISI marked), casing pipe having wall thickness 6mm as per IS-4270-2001 (Steel tube or water well), heavy grade, plain end, blank jointed with collar through electric resistanceof high frequency induction welding for increasing of length of pipe including necessary fittings and providing two coats of black bituminous paint (for drinking purpose) internally and externallycompleteall as specified and directed by Engr-in-Charge
64Assembling, lowering and fixing in position, 150mm bore, low carbon Glavanised Steel (LCG) Strainer with continuous slot screen (V-Wire Strainer) of 0.75 to 1.00 mm slot width to give an open area of 30.4% conforming to relevant IS and providing two coats of black bituminous paint (for drinking purpose) internally and externallycompleteall as specified and directed by Engr-in-Charge
65M&L for electric logging in pilot bore for precise delineation of granular zones as also the quality of ground water including report interpretation complete all as specified and as directed. (Note:- Electric logging shall be carried out by any approved Govt Agency)
66S&F well cap suitable for 200 mm bore housing pipe made out of 6 mm thick steel plate complete ( use for water well), heavy grade, plain end, blank jointed with collar through electric resistance welding completeall as specified and directed by Engr-in-Charge NOTE : After completion of the work well cap will be used to keep the bore well closed until the submersible pumping set is installed.
67M & L for developement of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water for 36 hrs completeall as specified and directed by Engr-in-Charge
68Yield test for the above bore well by continuously pumping for 16 hours to determine safe pumping yield and preparation of test sheet per hour specifying necessary parameters of testing complete all as specified and directed by Engr-in-Charge
69Material and labour for packing pea gravel 3 to 5 mm (or as per Geologist report) of size as per IS of natural shapebrought directly from river bed duly screened and packing around the casing pipe of MS to entire depth of tubewell upto ground level complete all as specified & as directed.
70Supply & laying galvanized steel tubing "Heavy grade"of size 80 mm bore with flanged ends ( threaded & Welded) long GI sockets and GI fittings incl bolts, nuts & washers in borewell all as specified& directed by EIC.
71Submersible pump, electric driven 415 V, TP suitable for 250 mm dia bore well ( Casing pipe size 300/350 mm) supply and Install complete upto 10 WHP inclusive of 40 metre long submersible cablecomplete all as specified and as directed
72Testing of raw water & treated water from approved Govt lab for potability by doing chemical (specially for iron (Fe, fluroide (F) and arsenic (As)) and bacteriological analysis as per norms of WHO and submission of test reports to the entire satisfaction of Engineer-in-Charge.
73Supply & laying and jointing 100mm diaDuctile Iron pipe, with spigot and socket ends suitable for push on rubber joint centrifugally castClass “K-9” inner side cement lining and outer side black bitumen coatinglaid in trenches including push on rubber (EPDM) ring with ISI markedcomplete all as specified and directed..
74Supply & laying and jointing 150mm diaDuctile Iron pipe, with spigot and socket ends suitable for push on rubber joint centrifugally castClass “K-9” inner side cement lining and outer side black bitumen coatinglaid in trenches including push on rubber (EPDM) ring with ISI markedcomplete all as specified and directed..
75Supply & laying and jointing 300mm diaDuctile Iron pipe, with spigot and socket ends suitable for push on rubber joint centrifugally castClass “K-9” inner side cement lining and outer side black bitumen coatinglaid in trenches including push on rubber (EPDM) ring with ISI markedcomplete all as specified and directed..
76Supply & laying and jointing 200mm diaDuctile Iron pipe, with spigot and socket ends suitable for push on rubber joint centrifugally castClass “K-9” inner side cement lining and outer side black bitumen coatinglaid in trenches including push on rubber (EPDM) ring with ISI markedcomplete all as specified and directed..
77Supply & laying and jointing 200mm diaDuctile Iron pipe, with spigot and socket ends suitable for push on rubber joint centrifugally castClass “K-7” inner side cement lining and outer side black bitumen coatinglaid in trenches including push on rubber (EPDM) ring with ISI markedcomplete all as specified and directed..
78Supply & laying and jointing 150mm diaDuctile Iron pipe, with spigot and socket ends suitable for push on rubber joint centrifugally castClass “K-7” inner side cement lining and outer side black bitumen coatinglaid in trenches including push on rubber (EPDM) ring with ISI markedcomplete all as specified and directed..
79Supply & laying and jointing 100mm diaDuctile Iron pipe, with spigot and socket ends suitable for push on rubber joint centrifugally castClass “K-7” inner side cement lining and outer side black bitumen coatinglaid in trenches including push on rubber (EPDM) ring with ISI markedcomplete all as specified and directed..
80Supply & laying and jointing 80mm diaDuctile Iron pipe, with spigot and socket ends suitable for push on rubber joint centrifugally castClass “K-7” inner side cement lining and outer side black bitumen coatinglaid in trenches including push on rubber (EPDM) ring with ISI markedcomplete all as specified and directed..
81Supplying and fixing Reflux Valves (NRV) with by pass arrangement supplied and installed complete of size 100 mm complete all as specified and directed.
82Supply and fix Cast Iron Air Valves with two air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains complete all as specified and directed.
83Supply and fix Cast Iron Air Valves with two air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains complete all as specified and directed.
84Supply and fix Foot Valve conforming to IS 4038, 100 mm diacomplete all as specified and directed.
85Supply and Install Pumping sets, centrifugal, electric driven,of capacity 3 WHPand PCC foundation complete all as specified and directed.
86Supply and InstallPumping sets, centrifugal, electric driven, of capactity10 WHP and PCC foundationcomplete all as specified and directed.
87Supply, install, connect, testing and commissioning of 3 phase 4 wire 50 Hz 415 Volts, Bus bar chamber with tinned copper bus bar FP 200 Ampsupported on FRP insulator and heat shrinked insulating sleeves, Indoor LT panel, compartmentalised cubical type with canopy, dust and vermin proof, free standing floor mounting type mountedon and incl 1:3:6 PCC platform with required mounting channel, feeder pillar box fabricated out of 2.0mm thick CRCA steel sheet duly pre treated and powder coated factory fabricated incl cable glands of suitable sizes and consisting the following:-Incoming:- (a)MCCB, FP 125 Amps, relay range 100-125 Amps with breaking capacity 30 KA - 01 No(b)Changeover switch 4 pole 160 A - 01 No (c) LED display in 96 x 96 sqmm flush mounted case accuracy class 1.0, 3phase, 4 wire, Panel mounted Multi function meter Make L&T complete with connected copper conductor wiring - 01 No(d) Phase indicating lamps LED type for RYB Phases - 1 set(e) CT coil 100/5A CT - 03 Nos Outgoing :- (a)MCCB, TP, 100Amps, relay range40-50 Amps with breaking capacity 25 KA - 03 No (b)MCCB, TP, 100Amps, relay range 25-32 Amps with breaking capacity 25 KA - 02 No(c)MCB DP 20 Amps - 02 Nos (d) CT coil 125/5A CT ( Set of 03 ) - 02 Nos(e) Digital Ammeter, three phase 5A, accuracy class 1.0, flush mounting type 96x96 mm,-02 Nos(f) Star Deta starter suitable for20 HP -2 Nos
88Construction of VALVE PIT TYPE "A" ofPCC block Masonryand of size 90 cm x 90 cm x90 cm (inner dimension) with all fittings and fixtures complete all as specified and shown on drawing No. TD/EM/6 Sheet 1/2
89Construction of VALVE PIT TYPE "A" ofPCC block Masonryand of size 120 cm x 120 cm x120 cm (inner dimension) with all fittings and fixtures complete all as specified and shown on drawing No. TD/EM/6 Sheet 1/2
90Supply and fix bleaching dozer bucket type of capacity 145 Litrescomplete all as specified and directed.
91S & F Aviation light of 100 Watt yellow painted LM6 alluminium alloy housing with heat resistant & toughenedglass coverand wire guard fitting built with controll gear, & eye bolt on top of Overhead tankcomplete all specified & directed
92S & F electronic water level indicator for overhead tank including all connecting items complete all specified & directed
93Supply, Installation & Commissioning Horizontal Monoblock Pump 10 HP capacity, 2 Stage, Suction and Delivery Size 80mm x 65mm having Discharge 20 LITERS PER SECOND at 40.00 Metre Head suitable for Working Voltage 415 Volts, 3 Phase and Testing, complete all as specified and as directed.
94Supply and fix Strainer Y type conforming to IS, size 300 mm dia
95Supplying and fixing Reflux Valves (NRV) with by pass arrangement supplied and installed complete of size 300 mm complete all as specified and directed.
96Supplying and fixing Reflux Valves (NRV) with by pass arrangement supplied and installed complete of size 150 mm complete all as specified and directed.
97Supply & fixing Sluice valve cast iron body class PN 1.6 with flanged ends drilled suitable for bore of pipe 300mm ISI marked havingbrass spindle with iron wheel at top including necessary fixing arrangements such as Mild Steel Nuts, Bolts, Washers, Gaskets, etc. including testing, complete all as specified and as directed.
98Supply and fix MS flanged pipe 80mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and as directed.
99Supply and lay 20mm diapipe galvanized, “Heavy class”, including fittings complete all as specified and as directed.
100Supply and fixing of RCC post of size 75x75x500 mm with 6 mm TMT barcomplete all as specified and as directed.
101Supply and fix hose box for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle , MS sheet 2 mm thickness complete all as specified and as directed.
102M&L Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 20mm bore nozzle short complete all as specified and directed.
103Supply and fix 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903complete all as specified and directed.
104Supply and fix 63 mm dia gun metal branch pipe with 12.5 mm nozzle conforming to IS 903 complete all as specified and as directed.
105Supply and fix Pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcmcomplete all as specified and as directed.
106Supply and fix Pumping sets, centrifugal, electric driven, supply and Install complete up to 2 HP inclusive of starter and PCC foundation for washing of hose pipescomplete all as specified and as directed.
107Supply and fixing Lightning arrestor sub station with all fittings, transmission class, discharge capacity 9 kA complete all as specified and directed.
108Supply and Installation of11 KV, 630 Amp Load break switch with 200 Amp DO set and earth switch complete all as specifiedand directed.
109Supply, installation testing and commissioning 315 KVA outdoor type transformer, step down 6KV/433V, 3 Phase 50 C/S AC double wound, core type copper wound, oil immersed naturally cooled (ONAN) with external cooling tubes, delta/star connection on primary side (6KV) , and star connection on secondary side (433V) in accordance withvector symbol DYN-11 and having tapping at +/- 2.5%,+/- 5% and +/-7.5% to be changed by means of manually operated OFF LOAD tap changing gear.The rate of temperature rise after continuous fall load shall be all as specified in IS -2026.The transformer shall be complete with the following:- (a) Cable entry box for LT on secondary side for 3.5 core 400 Sqmm XLPE cable and HT 3 core 95 Sq mm on primary side including fixing arrangement as specified and directed by Engineer-in-charge. (b) Oil conservator with filling cap, drain valve and oil level gauge. (c) Dehydrating breather with connecting pipe, first fill of dehydrating agent and oil seal. (d) Explosion relief vent mounted on tank with double diaphragm and equiliser pipe connection to conservator air space (pressure release device). (e) Air relief plug. (f) Shut off valve between the conservator and Bucholz relay. (g) Thermometer pocket.(h) 100 mm dial type temperature indicator having range 0-120 degree C vapour pressure type with maximum reading pointer/Max temp indicator and resetting device with alarm/trip contact and additional contacts for switching ON or OFF the colling fans. (j) Two earthng terminals on tank and tank cover with lugs to suit 32 mm x 6mm GI strip. (k) Rating and diagram plate.
110ITEM NO 18.75 CONT...(l) 100 mm dial type thermometer for winding temperature indicator having range 0 - 120 degree C vapour pressure type with maximum reading pointer/Max Temp indicator and resetting device with alarm/trip contact and additional contacts for switching ON or OFF to cooling fans (m) Drain valve with threaded adopter. (n) Filter valve with threaded adopder (top and bottom). (o) Sample valve. (p) Inspection covers. (q) Lifting lugs. (r) Four plane rollers, bidirectional, hinged type at the bottom for shifting transformer from one place to another place. (s) Top cover lifting eyes. (t) Double float Bucholz relay with trip and alarm contact. (u) Extra bushing outside the cable box for providing independent earthing. (v) First fill of transformer oil. (w) Rail section and channelemdedded in foundation of suitable size in and including PCC platform of size 4.0m x 4.0m x 0.60m (PCC 1:3:6) including ramp as per manufacturers recommendations.
111Supply, install, test and commission LT Panel Board, TPN 415 Volts, 50 Hz,indoor cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 2 mm thickwith 2 mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switchgears and the panel board shall be provided with proper ventillation including suitable size of cable alley Al bus bar suitable for carrying of current1000 Amps with suitable connections from MCCB & out going to main bus bar shall be carried out with TPN Al bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.200 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :-Incoming :- (a) 630A MCCB,4Pole, 250-630 A Relay, 70 kA -1 No (b) LCD multifunction meter - 01 No(c) CTs 630/5 A- set of 3(d) Phase indicator lamps (RYB) -set of 3(e) 1000 Amps Aluminium bus bar 4 strip(f)Internal wiring for panel incl insulators, sleeves etc (g) 630 A, 415 V manual change over, open execution -01 No
112ITEM NO 18.77 CONT.. Outgoing :- (a) 400A, MCCB,4P, 320-400 A Relay, 70 kA -1 No(b) 160A, MCCB,4P, 43-63 A Relay, 50 kA -1 No(c) 125A, MCCB,4P, 100-125 A Relay, 36 kA - 2 Nos (1 No spare)(d) 16A FP MCB, "C" Curve 10 kA -01 No (e) 16A DP MCB, "C" Curve 10 kA -2 No (f) 125A, MCCB,4P, 100-125 A Relay, 25 kA- 01 No(g) 100A, MCCB,4P, 32-40 A Relay, 25 kA-02 Nos (h) 100A, MCCB,4P, 25-32 A Relay, 25 kA -02 Nos(h) 100A, MCCB,4P, 25-32 A Relay, 25 kA -02 Nos
113Supply, install, test and commission LT Panel Board, TPN 415 Volts, 50 Hz,indoor cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 2 mm thickwith 2 mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switchgears and the panel board shall be provided with proper ventillation including suitable size of cable alley Al bus bar suitable for carrying of current600 Amps with suitable connections from MCCB & out going to main bus bar shall be carried out with TPN Al bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.200 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- Incoming :-(a) MCCB 400 Amps4 Pole 50 Hz 415 V with thermal magnectic release having rupturing capacity 50 KA - 1 Nos (b) LCD multifunction meter - 01 No(c) CTs 400/5 A- set of 3(d) Phase indicator lamps (RYB) -set of 3 (e) 600 Amps Aluminium bus bar 4 strip(f)Internal wiring for panel incl insulators, sleeves etc
114ITEM NO 18.79 CONT..... Outgoing :-(a)MCCB 320 Amps 3 Pole 50 Hz 415 V with thermal magnectic release having rupturing capacity 50 KA - 1 No. (b)MCCB 63 Amps 3 Pole 50 Hz 415 V with thermal magnectic release having rupturing capacity 50 KA -1 No (c)MCCB 32 Amps 4 Pole 50 Hz 415 V with thermal magnectic release having rupturing capacity 16 KA - 1 No (d)MCB 16 Amps SPN, 10 KA - 1 No (e)Fully Automatic Star-Delta Starter suitable for 170 BHP fire Pump - 1 No(f) Fully Automatic Star-Delta Starter suitable for 30 BHPSWT Pump - 1 No (g)DOL Starter suitable for 7.50 BHP jockey Pump - 1 No
115Supply, install, test and commission LT Panel Board, TPN 415 Volts, 50 Hz,indoor cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 2 mm thickwith 2 mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switchgears and the panel board shall be provided with proper ventillation including suitable size of cable alley Aluminium bus bar suitable for carrying of current250 Amps with suitable connections from MCCB & out going to main bus bar shall be carried out with TPN Aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.200 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- Incoming : -(a) MCCB 160 Amps 4 Pole 50 Hz 415 V with thermal magnectic release having rupturing capacity 36 KA - 1 Nos (b) LCD multifunction meter - 01 No (c) CTs 200/5 A- set of 3(d) Phase indicator lamps (RYB) -set of 3(e) 250 Amps Aluminium bus bar 4 strip (f)Internal wiring for panel incl insulators, sleeves etc (g) 125 A, 415 V manual change over, open execution -01 NoOutgoing :-(a) MCCB 100 Amps 3 Pole 50 Hz 415 V with thermal magnectic release20-25 A having rupturing capacity 25 KA -4 Nos (b) MCCB 32 Amps 4 Pole 50 Hz 415 V with thermal magnectic release having rupturing capacity 16 KA - 1 No(c) MCB 16 Amps SPN, 10 KA - 1 No (d) DOL Starter suitable for 10 BHPPumps - 4 Nos
116Supply, install, test and commission LT Feeder Pillar Box, TPN 415 Volts, 50 Hz,out door cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current200 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- Incoming :- (a)125A, MCCB,4P, 100-125 A Relay, 36 kA -01 No (b) LCD multifunction meter - 01 No (c) CTs 150/5 A- set of 3 (d) Phase indicator lamps (RYB) -set of 3(e) 200 Amps Aluminium bus bar 4 strip (f)Internal wiring for panel incl insulators, sleeves etc Outgoing :- (a) 100A, MCCB,4P, 50-63 A Relay, 25 kA -01 No (b) 100A, MCCB,4P, 25-32 A Relay, 25 kA - 01 No(c) 20A DP MCB, "C" Curve 10 kA -01 No(d) 16A FP MCB, "C" Curve 10 kA -04 No
117Supply, install, test and commission LT Feeder Pillar Box, TPN 415 Volts, 50 Hz,out door cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current300 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :-Incoming :-(a)125A, MCCB,4P, 100-125 A Relay, 25 kA -01 No(b) LCD multifunction meter - 01 No(c) CTs 200/5 A- set of 3 (d) Phase indicator lamps (RYB) -set of 3(e) 300 Amps Aluminium bus bar 4 strip(f)Internal wiring for panel incl insulators, sleeves etc Outgoing :- (a)100A, MCCB,4P, 50-63 A Relay, 25 kA -01 No (b) 16A FP MCB, "C" Curve 10 kA - 08 Nos(c) 16A DP MCB, "C" Curve 10 kA - 01 No
118Supply, install, test and commission LT Feeder Pillar Box, TPN 415 Volts, 50 Hz,out door cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current300 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :-Incoming :-(a)100A, MCCB,4P, 50-63 A Relay, 25 kA -01 No (b) LCD multifunction meter - 01 No (c) CTs 100/5 A- set of 3 (d) Phase indicator lamps (RYB) -set of 3 (e) 300 Amps Aluminium bus bar 4 strip (f)Internal wiring for panel incl insulators, sleeves etcOutgoing :-(a) 10A FP MCB, "C" Curve 10 kA - 14 Nos(b) 10A DP MCB, "C" Curve 10 kA - 01 No
119Supply, install, test and commission LT Feeder Pillar Box, TPN 415 Volts, 50 Hz,out door cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current300 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- Incoming :-(a)100A, MCCB,4P, 25-32 A Relay, 25 kA -01 No (b) LCD multifunction meter - 01 No(c) CTs 100/5 A- set of 3(d) Phase indicator lamps (RYB) -set of 3 (e) 300 Amps Aluminium bus bar 4 strip (f)Internal wiring for panel including insulators, sleeves etc Outgoing :- (a) 10A FP MCB, "C" Curve10 kA - 06 Nos(b) 10A DP MCB, "C" Curve 10 kA - 01 No
120Supply, install, test and commission LT Feeder Pillar Box, TPN 415 Volts, 50 Hz,out door cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current300 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- Incoming :-(a)100A, MCCB,4P, 32-40 A Relay, 25 kA -01 No (b) LCD multifunction meter - 01 No(c) CTs 100/5 A- set of 3 (d) Phase indicator lamps (RYB) -set of 3 (e) 300 Amps Aluminium bus bar 4 strip (f)Internal wiring for panel incl insulators, sleeves etcOutgoing :- (a)100A, MCCB,4P, 20-25 A Relay, 25 kA -01 No(b) 16A FP MCB, "C" Curve 10 kA - 04 Nos (c) 10A DP MCB, "C" Curve 10 kA - 01 No
121Supply, install, test and commission LT Feeder Pillar Box, TPN 415 Volts, 50 Hz,out door cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current300 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :-Incoming :- (a) 100A, MCCB,4P, 20-25 A Relay, 25 kA -01 No(b)LCD multifunction meter - 01 No(c)CTs 100/5 A- set of 3(d) Phase indicator lamps (RYB) -set of 3 (e) 300 Amps Aluminium bus bar 4 strip (f)Internal wiring for panel incl insulators, sleeves etc Outgoing :-(a)16A FP MCB, "C" Curve 10 kA - 04 Nos (b) 20A DP MCB, "C" Curve 10 kA - 01 No
122Supply, install, test and commission LT Feeder Pillar Box, TPN 415 Volts, 50 Hz,out door cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current300 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- Incoming :- (a) 100A, MCCB,4P, 25-32 A Relay, 25 kA -01 No(b)LCD multifunction meter - 01 No (c)CTs 100/5 A- set of 3(d) Phase indicator lamps (RYB) -set of 3(e) 300 Amps Aluminium bus bar 4 strip(f)Internal wiring for panel incl insulators, sleeves etc Outgoing :-(a)30A FP MCB, "C" Curve 10 kA - 04 Nos(b) 20A DP MCB, "C" Curve 10 kA - 01 No
123Supply and fix cable route indicator made of RCC (1:1:5:3) type AI of size 120 cm long, 15x15cm cross section at bottom tapered to cross section 10cmx10cm at top duly reinforced with 4 Nos 10 mm dia TMT main bars and 8 mm dia TMT bar as stirrups @ 150 mm c/c and engraved with LT MES to be installed at different places complete all as specified and as directed.
124S&F thermo-plastic cable junction box weather proof for street light of size 205x255x112 mm inclusive TPN connectors terminals for cable connection with IP 66/67 protection of make: Hensel, Cat No KF 1600C or equivalent in other approved makes incuding one MCB single pole 1 Amp, 240 volt, 10 kA "C" curve mounted on DIN rail and connecting all the incoming and outing cable terminals with lugscomplete all as specified and as directed.
125M&L for wiring with 2x1.5 sqmm plus 1x1.5 sqmm earth wire (nominal cross-sectional area) FRLS PVC insulated and unsheathed 1100 volts grade multistranded copper conductor cable drawn through and incl steel conduit of 20 mm dia medium grade from street light junction/ terminal box to street light fitting including clamps for fixing the PVC conduit with street light polescomplete all as specified and as directed.
126S&F Lithium based Energy Efficient Integrated Solar Street light 32 watt including MS pole duly painted with alluminium paint 6 mtr long 63 mm dia in Single FRP body encases Solar PV Panel 64/66Wp Monocrystalline , Lithium Battery 11.1/12.8V, 33.0AH with inbuilt BMS, High brightness W-LED(160-180 lm/watt) lamp with reflector, CRI >70, Color Temperature 6500K, Microcontroller based charge controller cum driver, automatic dimming function with PIR Motion Sensor, Dusk to Dawn Operation, Working temperature: (-) 10C to (+)55C, Weight: 18–20 kg, with adjustable MS clamp suitable for pole/wall mounting. Protections: Short Circuit, overload, Reverse polarity and battery protectionscomplete all as specified and as directed.
127S&F in replacement nature switch in enclosure made out of UV stablized, FR grade special moulding compound, rust proof, electric shok proof, vermine proof outdoor pole mountable with mounting bracket made out of FI and nut, bolts, washers including cable glands, openable door with lock comprising with power contactor three phase rating, 32 amps 4 pole-01 no, MCB SP 20 Amps-03 Nos for max load 5kw including taking down existing nature switch,IP 66 enclosurecomplete all as specified and as directed.
128Supply and fix LED Flood light 140 W IP 65 complete all as directed.
129Supply and fix high intensity long range manual revolving search light, 250 Watt MH type with adjustable focusing arrangement and suitable for rotating in both axis complete all as specified and as directed.
130Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.
131Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating set ISI marked Water cooled type, 415 volts, 3 phase 4 wire (Engine as per IS: 10001/10002 and alternator as per IS: 13364) complete with foundation as per manufacturer"s recommendation, standard AMF panel with necessary protection and meters including sound proof canopy of capacity 125 KVAincluding the following: -(a) ENGINEDiesel engine prime mover of suitable BHP to drive 100 KVA alternator with the following: - (i)Fuel level indicator(ii)Fuel tank of suitable capacity for storing minimum 8 hrs consumption capacity at 75% load.(iii) Fuel inlet arrangement from outside the acoustic enclosure with locking arrangement.(iv) Robust, MS base frame with anti vibration damper pads(v)Continuous 10% overload capacity in every 12 Hrs running.(vi) Self starting with and including suitable maintenance free battery of suitable AH rating as per OEM including charging circuit.(vii) Mechanical or Electronic governor as per OEM.(b) ALTERNATOR100 KVA at 0.8 PF (lag), 415 volt, 3 phase, 4 wire, 50 Hz, 1500 RPM copper wound with the following: -(i) Self regulated brushless self excitation.(ii)Automatic voltage regulator with band of voltage regulation: + 2.5% of rated voltage.(c) CONTROL PANELFactory fabricated free standing of suitable size copper bus bar with the following: -(i) MCCB 4 pole, 415 Volt, 3 phase of 160 Amps, 16 KA as per OEM.(ii) Internal wiring with suitable size copper conductor(iii)Start and Stop push button(iv)Digital voltmeter with selector switch(v) Digital frequency meter(vi)Digital ammeter with 3 Nos CT and selector switch(vii) Digital power factor meter(viii)Three phase energy meter(ix)Tripping arrangement with hooter for "High engine temp", "Low lub oil pressure", "High lub oil temp", Low and high engine speed" etc as per manufacturers" design.(d) ACOUSTIC ENCLOSURE It should be compact, modular construction and approved by ARAI (nodal agency of CPCB) with the following: -(i) Overall noise level less than 75 dB measured at 1 mtr distance in free field condition.(ii)Inside illumination provide with 2 Nos 1 x 9 watt LED light fitting or as per manufacturers" design.Note: - (i) The cost of foundation for installing the DG Setas per manufacturers" recommendation and is deemed to be included in the quoted rate (ii) First filling of fuel (DHPP(N) for 12 hours load test purpose shall be provided and cost deemed to be included in the quoted rate.(ii) Any accessories not mentioned but included in manufacturers standard modules are deemed to be included in the quoted rate.]
132Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating set ISI marked Water cooled type, 415 volts, 3 phase 4 wire (Engine as per IS: 10001/10002 and alternator as per IS: 13364) complete with foundation as per manufacturer"s recommendation, standard AMF panel with necessary protection and meters including sound proof canopy of capacity 50 KVAincluding the following: -(a) ENGINEDiesel engine prime mover of suitable BHP to drive 100 KVA alternator with the following: - (i)Fuel level indicator(ii)Fuel tank of suitable capacity for storing minimum 8 hrs consumption capacity at 75% load.(iii) Fuel inlet arrangement from outside the acoustic enclosure with locking arrangement.(iv) Robust, MS base frame with anti vibration damper pads(v)Continuous 10% overload capacity in every 12 Hrs running.(vi) Self starting with and including suitable maintenance free battery of suitable AH rating as per OEM including charging circuit.(vii) Mechanical or Electronic governor as per OEM.(b) ALTERNATOR100 KVA at 0.8 PF (lag), 415 volt, 3 phase, 4 wire, 50 Hz, 1500 RPM copper wound with the following: -(i) Self regulated brushless self excitation.(ii)Automatic voltage regulator with band of voltage regulation: + 2.5% of rated voltage.(c) CONTROL PANELFactory fabricated free standing of suitable size copper bus bar with the following: -(i) MCCB 4 pole, 415 Volt, 3 phase of 160 Amps, 16 KA as per OEM.(ii) Internal wiring with suitable size copper conductor(iii)Start and Stop push button(iv)Digital voltmeter with selector switch(v) Digital frequency meter(vi)Digital ammeter with 3 Nos CT and selector switch(vii) Digital power factor meter(viii)Three phase energy meter(ix)Tripping arrangement with hooter for "High engine temp", "Low lub oil pressure", "High lub oil temp", Low and high engine speed" etc as per manufacturers" design.(d) ACOUSTIC ENCLOSURE It should be compact, modular construction and approved by ARAI (nodal agency of CPCB) with the following: -(i) Overall noise level less than 75 dB measured at 1 mtr distance in free field condition.(ii)Inside illumination provide with 2 Nos 1 x 9 watt LED light fitting or as per manufacturers" design.Note: - (i) The cost of foundation for installing the DG Setas per manufacturers" recommendation and is deemed to be included in the quoted rate (ii) First filling of fuel (DHPP(N) for 12 hours load test purpose shall be provided and cost deemed to be included in the quoted rate.(ii) Any accessories not mentioned but included in manufacturers standard modules are deemed to be included in the quoted rate.]
133M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earthdolly forOne light point controlled by one, one way switch complete all as specified and directed
134M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earthdolly forone socket outletpoint 6amps on same board complete all as specified and directed
135M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earthdolly forone socket outletpoint 6amps on independent board complete all as specified and directed
136M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earthdolly for One light point controlled by one, two way switch complete all as specified and directed
137M & L for concealed Point wiring with 4 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run ofFRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4 Sqmm green in colour as earth continuity conductor connected to common earthdolly for one 16 Amp socket outlet on independent board complete all as specified and directed.
138S&F Switch piano flush buton single pole two way 5/6 Amps ISI marked complete all as specified and as directed.
139S&F Switch socket combination outlet 2 in 1, 5 Pin, 5 Amps flush type, 230 V (ISI marked) complete all as specified.
140S&FSwitch socket combination outlet 2 in 1, 6 Pin, 6/16 Amps flush type, 230 V (ISI marked) complete all as specified.
141M & L for Sub main Wiring with two run of 6.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and includingPVC conduit pipe medium grade of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed.Note: Two single core cable and one No. earth wire and one run of conduit shall be measured together as one length
142Supply and fixing LED lights fitting 1x 10 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
143Supply and fixing LED lamp 9W B-22 cool daylight suitable for bayonet cap type holder complete all as specified and directed.
144Supply of Precast RCC Dunnage Block (Size - 300 x 300 x 300 mm) including reinforcements,all as specified and shown on drawings.
145Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 m openable length (total length 90 m), having 50 nos rounds per 6 meter lenght, upto 3 m height of wall with existing angle iron "Y" shaped placed 2.4 m or 3.0 m apart and with 9 horizontal R.B.T. reinforcedbarbedwire ,stud tied with G.I. staples and G.I. clips to retainhorizontal ,including necessary bolts or G.I. barbed wire tied to angle iron ,complete as per direction ofEngr -In-Charge, with reinforced barbed tape (R.B.T.) /Spring core (2.5 mm Thick) wire of tensile strenght of 165 kg /sqmm with tape (0.52 mm thick) and weight 43.478gm/metre complete all as specified and directed. Note:cost of M.S. angle,C.C blocks shall be measured and paid separately
146Construction of Steel Gate with RCC pillar 5.50 m wide as per Drg No CESZ/2015/TD/34, Sht No 1/1and as specified
147Construction of Wicket Gate 1.20 m wide as per Drg No CESZ/2015/TD/34, Sht No 1/1and as specified
148M & L for Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including stove enamelled steel conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light point controlled by one, one way switch complete all as specified and directed.
149M & L for point wiring with 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including stove enamelled steel conduit ofadequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run ofFRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one 16 Amp socket outlet on independent board complete all as specified and directed.
Disclaimer :