Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | 2.5.2Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (butwithout MCB\"s and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door |
| 2 | 2.5.1Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (butwithout MCB\"s and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 12), Double door |
| 3 | 2.4.3 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB/ Isolator)8 way (4 + 24), Double door |
| 4 | 2.4.2 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door |
| 5 | 2.4.1 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB/ Isolator)8 way (4 + 12), Double door |
| 6 | 2.3.4Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door |
| 7 | 2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amp |
| 8 | 2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 9 | 2.15.1Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 10 | 2.14.3Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 11 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 12 | 2.14.1Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 13 | 2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 14 | 2.10.3Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 15 | 2.10.4Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 16 | 2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 17 | 2.13.3Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps |
| 18 | 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 19 | 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 20 | 2.12.2Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 21 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 22 | 2.20Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth,metal enclosed plug top alongwith 30 amps \"C\" curve, TPMCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 23 | 2.18Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 24 | 10.5.4Supplying and making outdoor cable endermination with heat shrinkable jointing kitompletewith all accessories including lugs suitable for following size of 3 core, XLPE aluminiumonductorcable of 11 KV grade as required :300 sq. mm |
| 25 | 10.4.4Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm |
| 26 | 9.1.31Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) |
| 27 | 9.1.30Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.3 1/2X 300 sq. mm (70mm) |
| 28 | 9.1.29Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) |
| 29 | 9.1.27Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm) |
| 30 | 9.1.26Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm) |
| 31 | 9.1.25Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 32 | 9.1.24Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) |
| 33 | 9.1.23Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 34 | 9.1.22Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 35 | 9.1.21Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) |
| 36 | 9.1.34Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 37 | 9.1.33Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 38 | 9.1.32Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 39 | 14.15.5Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal |
| 40 | 14.15.4Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 41 | 14.15.3Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 42 | 14.15.2Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 43 | 14.15.1Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal) |
| 44 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulatedcopper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 45 | 1.11Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 46 | 1.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( withoutindependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable insurface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single corecable etc. as required Group C. |
| 47 | 1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 48 | 1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings). |
| 49 | 1.56Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 50 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 51 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 52 | 1.27.3Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) |
| 53 | 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 54 | 1.27.5Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 55 | 1.27.6Supplying and fixing following size/ modules, GI Box along with modular base & cover plate for modular switches in recess as required. 12 module ( 200mm x 150mm) |
| 56 | 1.24.6Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.Telephone socket outlet |
| 57 | 1.24.7Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 58 | 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincludingconnection etc as required. |
| 59 | 1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 60 | 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 61 | 1.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5sq. mm + 1 X 2.5 sq. mm earth wire |
| 62 | 1.14.3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 63 | 1.14.4Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire |
| 64 | 1.14.5Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 65 | 1.14.6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16sq. mm + 1 X 6 sq. mm earth wire |
| 66 | 1.18.2Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in thexisting surface/ recessed steel/ PVC conduit as required.2 Pair |
| 67 | 1.18.3Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copperconductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 Pair |
| 68 | 1.19Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braidnd protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required. |
| 69 | 1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 70 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessedconduit as required.20 mm |
| 71 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 72 | 1.41Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 73 | 1.44Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required. |
| 74 | 1.50.1Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep |
| 75 | 1.47Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 76 | 2.22Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 77 | 2.21Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 78 | HT ENERGY METER Supply, installation, Testing and commissioning of CT, PT connected TOD Meter of approved brand and conforming to relevant IS and KSEB, Electrical Inspectorate regulations, IP 51 with unbreakable transparent cover, provision for sealing, anti-tamper features, real time and calibrated quartz clock tested by KSEB. This scope also includes the testing of TOD Meter and obtaining test certificate from Electrical Inspectorate / KSEB / TMR. (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents). |
| 79 | EMERGENCY PUSH BUTTON Supply, installation, testing and commission of Emergency Stop Push Button with enclosure for the Transformer. |
| 80 | MAIN SWITCH BOARD WITH AMFSupply, installation, testing & commissioning of inspecterate approved cubical type Main Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalised design from CRCA sheet steel of 1.6 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 1250 Amps capacity extensible type TPN Aluminum alloy bus bars of high conductivity,DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 32 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen) copper conductor cables, cable alleys etc. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Electrical Inspectorate and the consultant Busbar 2 Run of 75 x 10mm AL.Busbar for eachPhase1 Run of 75 x 10mmAL.Busbar for Neutral EB Incomer 1 Nos - 1250A, 50kA 4P Microprocessor based EDO ACB with O/C, E/F releases, having thermal memory, breaker contact wear and tear indication in percentage, provision to connect to computer through RS485 port in future and LSIG, Phase unbalance, Over temperature and Nuetral Protections. 1 Set - RYB Indication lamps with Control MCBs 3 Nos -630/5A CL:1, 10VA CT 1 Nos - Digital Multifunction Meter measuring V, A ,F, KWH, KVA, PF with Control MCBs 1 Nos - Stand by Earth Fault Relay DG Incomer - I 1 Nos - 1250 A 36kA 4P Microprocessor based EDO ACB with E/F releases, ROM and spreader 1 Set - RYB Indication lamps with Control MCBs 3 Nos - 400/5A CL:1, 10VA CT 1 Nos - Digital Multifunction Meter measuring V, A , F, KWH, KVA, PF with Control MCBs 1 Nos - 630A 4P Power Contactor (AC3) 1 Nos - Stand by Earth Fault Relay Surge Protection Device 3 Nos - 4 Module DIN Rail Mounting Type 1 + Type 2 / Class 1 + class II 100kA SPD on the incoming side of EB Incomer Supply, DG Incomer 1 Supply and DG Incomer 2 Supply with all accessories etc.complete as required. The connections to RYB Phases, Neutral and Earth shall be done using 16 Sq.mm Single Core Flexible Copper conductor cables with less than 0.45 m in length. Outgoings (On EB Incomer & DG - I Incomer) 2 Nos - 630A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader. 2 Nos - 250A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader. 1 Nos - 125A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader. 1 Nos - 125A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision and metering provision with E/F releases, ROM and spreader. |
| 81 | APFC PANEL 1&2 (120 KVAR) Supply, installation, testing & commissioning of Inspecterate approved cubical type Automatic Power Factor Correction Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 1.6 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 250 Amps capacity type TPN Aluminum alloy bus bars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen ) copper conductor cables, cable alleys etc. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Electrical Inspectorate and the consultant. Busbar 1 Runs of 32 x 10mm AL.Busbar for each Phase 1 Runs of 32 x 6 mm AL.Busbar for Neutral Incomer 1 Nos - 250A 4P Isolator 1 Set - RYB Indication lamps withControl MCBs 3 Nos - 250/5A CL:1, 10VA CT 1 Nos - Digital Multifunction Meter measuring V,A,F,KW, KVA,PF with Control MCBs 1 Nos - 8 Stage Microprocessor based APFC Relay 1 Nos - 630/5A CL:1, 10VA CT in MSB Outgoings 1 Nos - 63A TP MCB with Capacitor Duty Contactor and 25 KVAr Heavy Duty Cylindrical Type Capacitor. 2 Nos - 40A TP MCB with Capacitor Duty Contactor and 20 KVAr Heavy Duty Cylindrical Type Capacitor 2 Nos - 32A TP MCB with Capacitor Duty Contactor and 15 KVAr Heavy Duty CylindricalType Capacitor 2 Nos - 16A TP MCB with Capacitor Duty Contactor and 10 KVAr Heavy Duty Cylindrical TYPECapacitor 1Nos - 16A TP MCB with 5 KVAr Heavy Duty Cylindrical Type Capacitor 8 Nos - Green ON Push Buttons with Indicator 8 Nos - Red OFF Push Buttons with Indicator 2 Nos - Cooling Fan ( 6 Inches)< |
| 82 | SWITCH BOARD - 1 (Lighting Panel) Supply, installation, testing & commissioning of Inspecterate approved cubical type Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 1.6 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 200 Amps capacity type TPN Aluminum alloy bus bars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen) copper conductor cables cable alleys etc. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Electrical Inspectorate and the consultant. Metering 4 Nos - Busbar Provision for fixing CTs 1 Nos - Provision for fixing Three Phase Energy Meter Fuse & Neutral Link 3 Nos - 200A Open Type Fuse with HRC Fuse ofSuitable Rating 1 Nos - 200A Neutral Link Busbar 1 Runs of 32 x 10mm AL.Busbar for each Phase 1 Runs of 32 x 6mm AL.Busbar for Neutral Incomer 1 Nos - 125A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM, spreader 1 Set - RYB Indication lamps with Control MCBs 3 Nos - 200/5A CL:1, 10VA CT 1 Nos - DigitalMultifunction Meter measuring V, A , F, KWH, KVA, PF with Control MCBs 1 Nos - Earth Leakage Relay with CBCT Outgoings 4 Nos - 63A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader |
| 83 | ENERGY METER & CT Supply and installation of the following Energy Meter and CTs after getting it tested from Electrical Inspectorate / KSEB / TMR. (All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents.). Three Phase 4 Wire CL : 0.5 S (CT Operated) |
| 84 | ENERGY METER & CTSupply and installation of the following Energy Meter and CTs after getting it tested from Electrical Inspectorate / KSEB / TMR. (All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission ofsupporting documents.) 100/5A CL : 0.5S, 5VA Resin Cast CT |
| 85 | ENERGY METER & CTSupply and installation of the following Energy Meter and CTs after getting it tested from Electrical Inspectorate / KSEB / TMR. (All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission ofupporting documents.).150/5A CL : 0.5S, 5VA Resin Cast CT |
| 86 | ENERGY METER & CTSupply and installation of the following Energy Meter and CTs after getting it tested from Electrical Inspectorate / KSEB / TMR. (All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents.).200/5A CL : 0.5S, 5VA Resin Cast CT |
| 87 | SWITCH BOARD - 2 (Utility Panel) Supply, installation, testing & commissioning of inspecterate approved cubical type Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 1.6 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 500 Amps capacity type TPN Aluminum alloy bus bars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen) copper conductor cables cable alleys etc. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured aftergetting approval from the Electrical Inspectorate and the consultant. Busbar 1 Runs of 80 x10mm AL.Busbar for each Phase 1 Runs of 80x 6mm AL.Busbar for Neutral Incomer 1 Nos - 630A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM, spreader and shunt release 1 Set - RYB Indication lamps with Control MCBs 3 Nos - 500/5A CL:1, 10VA CT 1 Nos - Digital Multifunction Meter measuring V, A , F, KWH, KVA, PF with Control MCBs 1 Nos - Earth Leakage Relay with CBCT Outgoings 2 Nos - 400A 25kA 4PThermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM andspreader 2 Nos - 250A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader. |
| 88 | SWITCH BOARD - 3 (AC Panel) Supply, installation, testing & commissioning of inspecterate approved cubical type Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 1.6 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 400 Amps capacity type TPN Aluminum alloybus bars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switchgears with required size of AL. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen) copper conductor cables cable alleys etc. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Electrical Inspectorate and theonsultant. Busbar 1 Runs of 25x 6mmAL.Busbar for each Phase 1 Runs of 25x 6mm AL.Busbar for Neutral Incomer 1 Nos - 125A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM, spreader and shunt release 1 Set - RYB Indication lamps with Control MCBs 3 Nos - 125/5A CL:1, 10VA CT 1 Nos - Digital Multifunction Meter measuring V, A , F, KWH, KVA, PF with ControlMCBs 1 Nos - Earth Leakage Relay with CBCT Outgoings 5 Nos - 63A 25kA 4P ThermalMagnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader |
| 89 | 2.9.7Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dustprotected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto theterminal connector/ neutral link, earthing etc as required (But without MCB/ RCCB/ Isolator).(Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way Double door |
| 90 | 2.9.6Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dustprotected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto theterminal connector/ neutral link, earthing etc as required (But without MCB/ RCCB/ Isolator).(Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)6 way Double door |
| 91 | Supply and fixing of following ways surface / recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder coated, inclusive of 200A tinned copper bus bar,common neutral link, earth bar, din bar for mounting MCBs (But without MCBs and incomer) as required. 6 Way (8 + 18), Double door |
| 92 | MCCBSupply and fixing following rating and breaking capacity and pole MCCB with thermal magnetic release having 70 to 100% setting provision and terminal spreaders in the distribution board including making connections, etc. complete as required. 80A to 100A 25kA 4P MCCB |
| 93 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 100 milli amps |
| 94 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 100 milli amps |
| 95 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A to 63 A Triple Pole |
| 96 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps |
| 97 | METAL ENCLOSURESupply and fixing Sheet Steel enclosure on surface / recess having provisionto fix MCB / Isolator complete with connections, testing and commmissioning etc. as required. 4 Way |
| 98 | METAL ENCLOSURESupply and fixing Sheet Steel enclosure on surface / recess having provision to fix MCB / Isolator complete with connections, testing and commmissioning etc. as required. 2 Way |
| 99 | Star-Delta STARTER Supplying, installation, testing & commissioning of Star-Delta Starter Switch Panel enclosure suitable for 5HP to 10HP compressor complete with all accessories including 4P Power Contactors, Overload Relay, ON-OFF Push Buttons, etc. complete with wiring in duly powder coated sheet steel enclosure. |
| 100 | DOL STARTERSupplying, installation, testing & commissioning of DOL Starter Switch Panel enclosure suitable for 5HP to 10HP compressor complete with all accessories including 4P Power Contactor, Overload Relay, ON-OFF Push Buttons, etc. complete with wiring in duly powder coated sheet steel enclosure. |
| 101 | HT CABLE Supply, laying, testing and commissioning of 11 KV grade XLPE insulated armoured cables of the following size and laying in earth excavated trenches, clamping in built up trenches, traysusing heavy duty Aluminium or GIFlat or by using heavy duty GI spacer saddles and on 11 KV pole structure using necessary heavy duty GI supports and clamps of which spacing of clamps not exceeding 50 cm and pulling through pipes etc including all minor civil works. 3C x 300 Sq.mm |
| 102 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 25 Sq.mm Al. cable |
| 103 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 35 Sq.mm Al. cable |
| 104 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 50 Sq.mm Al. cable |
| 105 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 70 Sq.mm Al. cable |
| 106 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 95 Sq.mm Al. cable |
| 107 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 120 Sq.mm Al. cable |
| 108 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 150 Sq.mm Al. cable |
| 109 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 185 Sq.mm Al. cable |
| 110 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 240 Sq.mm Al. cable |
| 111 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 300 Sq.mm Al. cable |
| 112 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 3.5C x 400 Sq.mm Al. cable |
| 113 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 2C x 1.5 sq.mm Copper Armoured Cable |
| 114 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 4C x 1.5 sq.mm Copper Armoured Cable |
| 115 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 2C x 2.5 sq.mm Copper Armoured Cable |
| 116 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 4C x 2.5 sq.mm Copper Armoured Cable |
| 117 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 4C x 6 sq.mm AI Cable |
| 118 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 4C x 10 sq.mm AI Cable |
| 119 | LT CABLES Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works. 4C x 16 sq.mm AI Cable |
| 120 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired. 2C x 1.5sq.mm. Copper Armoured cable |
| 121 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C x 1.5sq.mm. Copper Armoured cable |
| 122 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2C x 2.5sq.mm. Copper Armoured cable |
| 123 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C x 2.5sq.mm. Copper Armoured cable |
| 124 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C x 6 Sq.mm AI Cable |
| 125 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 3.5C x 300 Sq.mm Al. cable |
| 126 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 3.5C x 400 Sq.mm Al. cable |
| 127 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 3.5C x 240 Sq.mm Al. cable |
| 128 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 3.5C x 185 Sq.mm Al. cable |
| 129 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 3.5C x 120 Sq.mm Al. cable |
| 130 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 3.5C x 150 Sq.mm Al. cable |
| 131 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 3.5C x 70 Sq.mm Al. cable |
| 132 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 3.5 C x 95 Sq. mm AI. cable |
| 133 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 2C x 2.5sq.mm. Copper Armoured cable |
| 134 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 4C x 2.5sq.mm. Copper Armoured cable |
| 135 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 4C x 6 Sq.mm Al. cable |
| 136 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 4C x 10 Sq.mm AI. Cable |
| 137 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 4C x 16 Sq.mm Al. cable |
| 138 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 4C x 25 Sq.mm Al. cable |
| 139 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 3.5C x 35 Sq.mm Al. cable |
| 140 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 3.5C x 50 Sq. mm AI. Cable |
| 141 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 2C x 1.5sq.mm. Copper Armoured cable |
| 142 | GLAND EARTHING Supply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical InspectorateStandards. 4C x 1.5sq.mm. Copper Armoured cable |
| 143 | PLATE EARTHING Supply and providing earthing with CI earth plate 600mm x 600mm x 6mm thick electrode including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required conforming to relevant IS, Electrical Inspectorate standards etc |
| 144 | EARTHING CONDUCTORS Supply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc. using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned andonnections should only be done using SSNut and Bolts with double washers etc as required. 8 SWG Copper Wire |
| 145 | EARTHING CONDUCTORS Supply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc. using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SS Nut and Bolts with double washers etc as required. 10 SWG Copper Wire |
| 146 | EARTHING CONDUCTORS Supply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc. using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SS Nut and Bolts with double washers etc as required. 25 x 3 mm Copper Strip |
| 147 | EARTHING CONDUCTORS Supply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc. using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SSNut and Bolts with double washers etc as required. 25 x 6 mm Copper Strip |
| 148 | EARTHING CONDUCTORS Supply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc. using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SS Nut and Bolts with double washers etc as required. 25 x 6 mm GI Strip |
| 149 | MS STRUCTURALS Supply, fabrication and installation of checkered plates of 6mm thickness to use above the cable trenches duly supported with channels and duly painted with one coat of epoxy primer and two coats of epoxy grey paint. |
| 150 | MS STRUCTURALS Supply, fabrication and installation of Transformer, Panel Board mountingsupports using C Channels of adequate size painted with one coat of epoxy primer and two coats of epoxy grey paint. |
| 151 | MS STRUCTURALS Supply, fabrication and installation of cable tray and supports using M.S angles and plates of adequate size painted with one coat of epoxy primer and two coats of epoxy grey paint. |
| 152 | CABLE ROUTE MARKER Supply and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted / welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long with painting and fixing the same in ground at 5 meter interval with cement concrete in M.15 Grade (1:2:4) etc. complete as required. |
| 153 | PIPES FOR CABLE PROTECTION Supply and laying of the following size medium class GI pipe in ground or clamping in wall/ceiling with heavy duty GI or Aluminium clamps etc complete as required. 25 mm dia |
| 154 | PIPES FOR CABLE PROTECTIONSupply and laying of the following size medium class GI pipe in ground or clamping in wall/ceiling with heavy duty GI or Aluminium clamps etc complete as required. 50mm dia |
| 155 | PIPES FOR CABLE PROTECTION Supply and laying of the following size medium class GI pipe in ground or clamping in wall/ceiling with heavy duty GI or Aluminium clamps etc complete as required. 80mm dia |
| 156 | PIPES FOR CABLE PROTECTION Supply and laying of the following size medium class GI pipe in ground or clamping in wall/ceiling with heavy duty GI or Aluminium clamps etc complete as required. 100mm dia |
| 157 | PIPES FOR CABLE PROTECTIONSupply and laying of the following size medium class GI pipe in ground or clamping in wall/ceiling with heavy duty GI or Aluminium clamps etc complete as required. 150mm dia |
| 158 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 3 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 159 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required. Data socket outlet |
| 160 | STREET LIGHTING POLE Supply, installation, testing & commissioning of 7 meter high hot dip galvanised Octagonal poles with double arm bracket, 130mm bottom dia and 70mm top dia made up of 3mm thick sheet along with base plate of size 200 x 200 x 12mm. |
| 161 | STREET LIGHTING POLE Supply, installation, testing & commissioning of 8 meter high hot dipgalvanised Octagonal poles with double arm bracket, 130mm bottom dia and 70mm top dia made up of 3mm thick sheet along with base plate of size 200 x 200 x 16mm |
| 162 | STREET LIGHTING POLE Supply, installation, testing & commissioning of 9 meter high hot dipgalvanised Octagonal poles with double arm bracket, 155mm bottom dia and 70mm top dia made up of 3mm thick sheet along with base plate of size 250 x 250 x 16mm |
| 163 | STREET LIGHTING LED Supply, installation, testing & commissioning of the following WattsGraphite grey powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws. LEDs shall provided with secondary lens optics to get optimum optical performance. he drivers used shall be specially designed to have built-in surge voltage, open / short circuit protections.Internal surge of 5 KV and External surge protection of 10 KV provided for additional safety. Luminaire shall have CCT of 5700, CRI >70, IP 66 protection, IK 07, PF>.95, THD <10%,operating voltage range of 150 - 300v AC, and 120 Lumesn/watt efficiency with a lumen package of 12000 70 W |
| 164 | STREET LIGHTING LED Supply, installation, testing & commissioning of the following WattsGraphite grey powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws. LEDs shall provided with secondary lens optics to get optimum optical performance. he drivers used shall be specially designed to have built-in surge voltage, open / short circuit protections.Internal surge of 5 KV and External surge protection of 10 KV provided for additional safety. Luminaire shall have CCT of 5700, CRI >70, IP 66 protection, IK 07, PF>.95, THD <10%,operating voltage range of 150 - 300v AC, and 120 Lumesn/watt efficiency with a lumen package of 12000 100 W |
| 165 | STREET LIGHTING LED Supply, installation, testing & commissioning of the following WattsGraphite grey powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws. LEDs shall provided with secondary lens optics to get optimum optical performance. he drivers used shall be specially designed to have built-in surge voltage, open / short circuit protections.Internal surge of 5 KV and External surge protection of 10 KV provided for additional safety. Luminaire shall have CCT of 5700, CRI >70, IP 66 protection, IK 07, PF>.95, THD <10%,operating voltage range of 150 - 300v AC, and 120 Lumesn/watt efficiency with a lumen package of 12000 120 W |
| 166 | STREET LIGHTING Foundation Providing required RCC foundation for Street Light Pole after excavating of the soil to the required depth. The concrete mix for PCC shall be in M:15 Grade (1:2:4) and that of RCC shall be in M:20 Grade (1:1.5:3). The contractor shall submit the drawings of the foundation to the Engineer/ Manager in charge and Consultant for getting approval before the commencement of work or the work shall be executed as per the drawings given to the contractor. |
| 167 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite 2 x 2 (2 Feet x 2 Feet) LED Light |
| 168 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite Industrial type LED Tube Set of 2 x 20W with Tube |
| 169 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite Industrial type LED Tube Set of 1 x 20W with Tube |
| 170 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite LED Bulb (up to 12W) |
| 171 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items at site Battern/Angle Holder |
| 172 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite High Speed Metal Type Exhaust Fan of Sweep 200 mm |
| 173 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite High Speed Metal Type Exhaust Fan of Sweep 225mm |
| 174 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite 60W Ceiling Fan of Sweep 1200mm |
| 175 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite 50W LED Flood Light |
| 176 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite 100W LED Flood Light |
| 177 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite 120W LED Highbay Light |
| 178 | SUPPLY OF LIGHT & OTHER FITTINGS Supply and providing the following fittings and items atsite High Speed Metal Type Exhaust Fan of Sweep 150 mm |
| 179 | INSTALLATION OF LIGHT & OTHER FITTINGSInstallation, testing and commissioning of 50W LED Flood light fittings complete with all accessories directly on wall/ piller/ceiling, including giving connections etc. as required |
| 180 | INSTALLATION OF LIGHT & OTHER FITTINGS Installation, testing and commissioning of 100W LED Flood light fittings complete with all accessories directly on piller/ceiling, including giving connectionsetc. as required |
| 181 | INSTALLATION OF LIGHT & OTHER FITTINGS Installation, testing and commissioning of 120W LED Highbay light fittings complete with all accessories directly on ceiling, including giving connections etc. as required. |
| 182 | INSTALLATION OF LIGHT & OTHER FITTINGS Installation, testing and commissioning of 2 x 2 (2 Feet x 2 Feet) LED Ceiling light fittings complete with all accessories directly on the ceiling by cutting the ceiling including giving connections etc. as required. |
| 183 | INSTALLATION OF LIGHT & OTHER FITTINGS Installation, testing and commissioning of PVC battern / angle holder fitting complete with all accessories directly on ceiling/wall, including giving connections etc. as required. |
| 184 | POINT WIRINGSupply and fixing suitable size GI box / PVC surface box with modular plate and socket outlet and 15/16 A modular switch, connections etc. as required cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular |
| 185 | CIVIL Supply of all materials and providing electrical room of 30 x 20 ft for USS and Panels including roofing , transformer foundation and alteration of existing Building |
| 186 | FAN RODSupply and fixing extra down rod of 20cm legnth G.I pipe 15mm dia, heavy guage including painting etc. as required. (Note: More than 5cm length shall be rounded to the nearest 10cm and 5cm or less shall be ignored). |
| 187 | SAFETY EQUIPMENTSSupply and fixing laminated shock treatment chart duly mounted on a good frame work |
| 188 | SAFETY EQUIPMENTSSupply and providing First Aid Box as approved by St.John Ambulance Brigade / Indian Red Cross conforming to IS 2217 : 1963 |
| 189 | SAFETY EQUIPMENTS Supply and providing a set of 2 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint \"FIRE\" and mountedon MS angle iron frame with bracket of appropriate size and capacity including filling sand etc. |
| 190 | SAFETY EQUIPMENTS Supply and fixing safety instruction chart in word duly framed in good frame work as required. |
| 191 | SAFETY EQUIPMENTS Supply and fixing 2Kg Dry Chemical Powder (DCP) type fire extinguisher complete with Gun Metal cap, hose with squeeze grip nozzle, wall fixing brackets conforming to BIS: 2171 and with ISI mark |
| 192 | SAFETY EQUIPMENTS Supply and providing tested industrial safety helmet conforming to IS 2925 : 1984 |
| 193 | SAFETY EQUIPMENTS Supply and providing 11KV tested discharge rod conforming to IEC 61230 |
| 194 | SAFETY EQUIPMENTS Supply and providing 1 pair of 11KV tested rubber gloves conforming to IS 4770 : 1991. |
| 195 | SAFETY EQUIPMENTS Supply and providing electrical grade rubber mat of size 2m x 1m having 6mm thickness in front of panels and DBs conforming to IS 15652 : 2006 standard. |
| 196 | SAFETY EQUIPMENTSSupply and providing electrical grade rubber mat of size 2m x 1m having 12mm thickness in front of panels and DBs conforming to IS 15652 : 2006 standard. |
| 197 | DOCUMENTATION Co-ordination with KSEB for getting power allocation by submission of 7 sets of HT agreement and executing the agreement etc.(All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents). |
| 198 | DOCUMENTATION Submission of completion report, arranging inspection and obtaining Sanction Order from Electrical Inspectorate .(All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents). |
| 199 | DOCUMENTATION Preparation of drawings and getting approval from Electrical Inspectorate. (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents). |
| 200 | DOCUMENTATION Taking soil resistivity at site and obtaining test certificate from ElectricalInspectorate (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents). |
| 201 | NOTE 1 : Sl No, 79 are not included in the scope of work and hence not shown in this BOQ.NOTE 2 :As per standing GO, Defect liability period is 36 months from the date of completion or asset handover to customer and shall be applicable to this work. Any repair and maintenance shall be provided by the contractor at own cost during warranty period |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy