| 1 | PART-A |
| 2 | Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water and BEE 5 star rated capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category B motor) and as per technical specification given in NIT Method of starting – star deltaa) Discharge-33 M3/Hour, Total head -62 MtrTube Well size-250mmN.B-T.C. & G.C. needed.(Manufacturer test certificate along with curve chart should be submitted at the time of delivery) |
| 3 | Supply and delivery of the following materials at site : - |
| 4 | Safety device for the above pump set by supplying MS cage with proper clamping arrangement and nylon rope as per requirement including supply of all required materials with nuts and bolts as required |
| 5 | MS E.R.W as per IS:1239 80mm. dia Heavy type 4.85 mm thick Column pipe with one end socketted and both end threaded |
| 6 | 3 mtr long |
| 7 | 1.5 mtr long |
| 8 | Heavy type MS fabricated suspension clamp suitable for above 80 mm ? column pipe with necessary nuts and bolts. |
| 9 | Split type MS fabricated suitable tubewell cover as per tubewell housing with a necessary arrangement for clamping devices including holes for air pipe and cable entry gland |
| 10 | Supply and delivery of following valves |
| 11 | 80 mm dia CIDF single door swing check Non Return valve(P.N-1.6) generally conforming to IS 5312 Part I for 80mm delivery line and as per technical Specification given in NIT |
| 12 | 80mm dia CIDFnon-rising Sluice Valve (P.N-1.6) generally conforming to IS 14846 and as per technical Specification given in NIT(for 1 no by pass arrangement) |
| 13 | Supply and delivery ofthree phase actuator and actutator operated 80mm dia flange type slim seal wafer type butterfly valve (PN-1.6) as per Bs-5155 having valve body of steel cast and shaft steel (AISI-410)Actuator and as per technical Specification given in NIT |
| 14 | 102mm ? 0-12 Kg / cm2 pressure gauge with brass three way cock and syphone and other necessary fittings |
| 15 | Supply and delivery of 80mm diafollowing GI specials for delivery line |
| 16 | Tee |
| 17 | Pipe (TATA Medium) |
| 18 | Bend (90\") |
| 19 | flange (G.I) heavy type for 80 mm dia |
| 20 | Plug |
| 21 | Socket |
| 22 | Supply and delivery of 50mm diafollowing GI specials for Cable Protection |
| 23 | 100mm long short piece |
| 24 | Bend (90\") |
| 25 | Union |
| 26 | Pipe (TATA Medium) |
| 27 | Supply, delivery and storage at site of following cables |
| 28 | 6 sqmm 3core, 1100 Volt grade copper water proof PVC insulated submersible flat submersible cable,Conforming To IS : 694 As Amended Up To Date. |
| 29 | 2.5 sq mm , 12 core , 1.1 KVGrade PVC insulatedCopper Armoured control cable Armoured and Extruded PVC Type ST2 Outer Sheathed As Per IS-7098 (Part 1) 2011 with Up To Date Amendments. |
| 30 | 35mm2 3.5Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments,(From WBSEDCL meter to MCC & through Voltage stabilizer) |
| 31 | 25mm2 3Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments,(From MCC meter to out door Kiosk Box) |
| 32 | N.B- All cables should be purchased as per site condition |
| 33 | Supply, deliveryat site of following items |
| 34 | Supplying delivery of 100 Amps 415 Volt TPN Sheet steelenclosed re-wireable fuse type Main Switche with side handle operated . |
| 35 | Supplying delivery of 100 Amps 415 Volt TPN Sheet steelenclosed Onload Changeover Switch side handle operated. |
| 36 | Supply and fitting fixing of wall mounted 415 Volt TPN sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as requiredi)100 Amp 4way |
| 37 | Supply and delivery of 415 Volt MCC cum PDB with minimum 2mm thickness and degree of protection IP-54, conforming to IS-8623 with suitable Bus Bar, Digital Voltmeter, Ammeter, contractor, delay timer, MCB, Valve actuator stater etc. with PLC logic & UPS and detailed in as per tecnical specification given in NIT. i) 7.5-12.5 H.P with SDS (Star, Delta ) StarterN.B. Single line diagram ,bills of materials and internal circuit diagram should be submitted for approval before delivery of Panel. |
| 38 | Supplyand delivery 20KVA oil coolling type Voltage Stabiliser, having unbalance 200 - 500 V input voltage, and 415(±1%) out put voltage , Auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with contactor at out put side, input MCB, Ammeter Bell etc. as per I.E rules and as per tecnical specification given in NITN.B.:- Manufacturer Test Certificate for Stabilizer, core material, winding copper & oil should be produced at the time of delivery |
| 39 | Supply, delivery and automatically controlled diaphragm type chlorinator dosing pump with Flow Rate 200 Ltr./Hr. and Max pressure of 12kg/cm2) with all relive valve and diaphragm rupture indicator , pressure gauge , parure switch, base plate, flexible coupling guard for pump and Motor, foundation bolt,dosing solution of 200 Ltr. capacity and the prime mover to be coupled with pump of 2 HP 3 Phase 1450 RPM squirrel cage TEFC induction Motor, Motor will be IE3(Make of Machine: As per attached vendor list of P.H.E Dte.) |
| 40 | Supply and delivery of 450mm(H) x 300(L) x 250mm(B) size out door CRCA sheet steelfabricated cubical type kenopy top cable jointing box inside fitted6 nos 100 Amp rated bus bar andhinged type front door and painted powder coated anticorrosive paint as per IP 55 as per direction of E.I.C |
| 41 | Supply deliveryof outdoor typeLED light fixture Operating Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set.(M.No-BRP409 LED130 CW SLC FG PSU GR V2 |
| 42 | Supply delivery80mm diaM.S Black pipe Medium (Class B) as per IS:1239 PART-1 (2004). i) 1.5 mtr long each x 3 nos for each pump house x 3 nos Pump house(For holding Arm at Pump House Roof) |
| 43 | Supply delivey of 1.5 mtr. long M.S Arm bracket made out of40 mm dia MS pipe with painted anticorrosive paint . |
| 44 | Supply and delivery of 1200 mm sweep, 1 phase, 60/70 watt, 5 star and having 300 mm down rod, 1.1mm thick alluminium bled, conforming IS 374, 2 mm shank thickness ceilling fan |
| 45 | PART-B |
| 46 | Installation of the above PLC automatic panel with pumping machinery,Voltage Stabiliser, Chlorine machine of item no (1 to 16) excluding item no-[7.2 7.3, 7.4 & 12] outdoor lighting, outdoor type actuater making delivery line, washoutline by the G.I specials, with cable protection pipe,including cable finishing, supplying ofall necessary metrials andincluding necessary finicing of serounding area of T/Wby the brick works, plastering, Net finishing etc and cost of hiring D.G set ( if required) to complete the jobs including Painting of anty corrosive paint in all respect as per tecnical specification and as per direction of E.I.C. |
| 47 | Laying of two nos 25 sqmm 3 core Al, Ar Cable and Controll cable in an underground trench in singletier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed |
| 48 | Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mendinggood damages and painting |
| 49 | Making 300mm(W) x 300mm(B) x 900 mm (H) size rising main supporting brick pillar at least 300mm depth from ground level to pumping floor level and neat cement finish all complete as per direction. |
| 50 | Installation of Cable jointing box by the making 450mm(W) x 450mm(B) x 1000mm(H) sizebrick pillar at least 300mm depth from ground levelor as per requirement including plastering and net cement finish all complete as per direction. |
| 51 | Lighting and luminaries arrangement at the PDB cum MCC Roomincluding internal wiring ofthe P/H building. as per technical specification. |
| 52 | Making double Earthing arrangement in complience with I.E rules by G.I pipe electrode with G.I funnel (50mmx 3 mtrlong) direcrt ground with supplying and fixing of G.I earth busbar drawing of 25mmx 6mm G.I earth conductor between pits and as earth busbar inside the pump house and 20mmx 3 mm GI strips for continuty to different electrica; installation i.e main switch panel and feeder box etc and making suitable size earth pit etyc all complete.For MCC Panel & Voltage Stabilizer |
| 53 | Earthing of cable jointingbox with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.incl GI bolts, double nuts, double washers . GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and size86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside)and CI hinged inspection cover of 36.56 cm x 35.56 cm with locking arrangement, and connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised stripBy ISI-Medium GI pipe |
| 54 | Providing & Installation of Solar Photo Voltaic Panelsas per MNRE Specification forsize of solar plantwith necessary PV arraymounted on independent steel structure of suitable height &in a suitable direction to optimize panel use and withstand the wind pressure up to 200 Km /hourincluding necessary 3 phase inverter, cable, switch/circuit breaker/connector/junction box, earthing, lightening arrester, installation & commissioning with 5 year CMC. (a) The PV Modules should be mounted on hot dip galvanized metallic structure of adequate strength and as per drawing given in NIT(b) Components & parts used in the solarsystem including the metallic structure (MS) should confirm to the BIS(c) The rates of solarsystem includes compressive maintenance contract for 5 years .[For T/W No-I, II] |
| 55 | Construction of RCC foundationfor mounting Steel structure for installation of Solar panel Array including earth excavation, sand filling, brick soling etc and as per speecification given in NIT.[For T/W No-I, II] |
| 56 | Testing commissioning of the whole installation with proper functioning of system by PLC system in fully automatic condition and other electrical equipments to ensure performance of the equipment in running satisfactiory as per direction of E. I. C. |
| 57 | Cost of supply and delivery at site of calcium hypochlorite granule minimum CI content 60%-65% in air plastic jar (3kg each) as per direction of EIC. [For T/W No-I, II ] |
| 58 | Supply and delivery of safety equipment like Rubber Mat, fire extenguser, hand gloves etc as per technical specification given in NIT[For T/W No-I, II ] |
| 59 | Trial run of pumping machinery, through PLC / Automatic panel also operation of Chlorinator, V.S etc. including operation of rising main valve if required and guarding of installationas per direction of E.I.C.(90 days)[For T/W No-I & II] |
| 60 | PART-C [ High Must for OHR site ] |
| 61 | Supply and delivery and storage of the following at site |
| 62 | 8mtr octagonal sections pole suitable for 50m/sec wind speed with raising lowering system comprising ,head frame ,luminaries carriage suitable to install 6 nos luminaries in symmetrical arrangement, double drum winch , 6mm dia SS wire rope trailing cable ,connector , integral power toolmotor, manual handle, junction box, lightening arrester and foundation bolts manufactured from special steel along with nuts, washer,anchor plate and common template. |
| 63 | Flood lighting luminaire with single die ceramic base highpower LED, PDC housing & integrated flood optics to ensure uniform distribution maintenance free system, ideal for sports lighting, arealighting and high mast lighting.- M.No-BVP483 LED210 CW AWB PSU GR |
| 64 | LED type single dome aviation obstruction light suitable for above high must, |
| 65 | Surge protection device suitable for both 1+2 type protection 3 phase system 440V max operating voltage and max current 40KA along with sheet steel enclosure make- as per approved unified vendor list vide official website of WBPHED |
| 66 | 32 Amps 415 Volt TPN re-wireable fuse type side handle operated and fixing Sheet steel Main Switch |
| 67 | 10sqmm 4 core 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments, |
| 68 | Laying of above cable through the under ground trench having depth 760mmX width 460mm and laying 8 nos brick for per mtr length of the cable for protection of the cable including sand filling ramming complete as per IE rules as per direction of the EIC. |
| 69 | Construction of shallow foundation with M20 grade concrete for the high mast considering the safe soil bearing capacity at site as10T/sq mt at 2 mtr depth with all materials and labour as per direction of EIC. |
| 70 | Erection and commissioning of the above pole with the help of suitable tools and plants wiring of luminaries with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor of 1.5 sq mm lugs, MCB and all labour as per direction of EIC |
| 71 | Provision of GI pipe earthing for high mast with 3 mtr long 50 mm dia GI pipe including connection to high mast earth terminal with 25 x 6 mm GI flats with all materials and labour as per direction of EIC |
| 72 | Add: 18% GST |
| 73 | Add: 1% Cess |