Tender For Tender For Supply Of Laboratory Equipments And Instruments, panaji-Goa

Goa Medical College has published Tender For Tender For Supply Of Laboratory Equipments And Instruments. Submission Date for this Tender is 14-12-2022. Laboratory Equipment Tenders in panaji Goa. Bidders can get complete Tender details and download the document.




Tender Notice

35128089
Tender For Tender For Supply Of Laboratory Equipments And Instruments
Open Tender
Indian
Goa
panaji
14-12-2022

Tender Details

Tender For Supply Of Laboratory Equipments And Instruments , Double Beam Uv – Visible Spectrophotometer: 1) Instrument Should Be Possible To Use Standalone With Usb Pen Drive Support For Data Storage. 2) Standalone Instrument Should Be Able To Connect To Printer With Usb Port. 3) Standalone Instrument Should Have Lcd Display Of Minimum 125 X 90Mm Size. 4) Instrument Should Be Able To Use With Pc With Latest Windows -7 Compatible Instrument Software. 5) Instrument Control Pc Software Compatible With Windows-7 Should Be Supplied Along With The Instrument. 6) Instrument Should Have Lamp Hour Usage Monitoring With Display Of Lamp Hours Consumed. 7) Hardware Specifications Required: (A) Wavelength Range: 190Nm To 1100Nm (B) Monochromator: Blazed Holographic Grating With Crenzy Turner Mountings. (C) Spectral Bandwidth: 1Nm Over Entire Range (D) Wavelength Accuracy: +/-0.3Nm Over Entire Range (E) Wavelength Repeatability: +/- 0.1Nm. (F) Light Source: Separate Deuterium And Tungsten Lamp For Uv And Vis Range (G) Lamp Changeover: Automatic And User Selectable Lamp Changeover Between Uv To Visible Range (H) Noise Level: Less Than 0.00005Abs. (I) Detector: Silicon Photodiode. (J) Sample Compartment: Sample & Reference Cells Should Be Mounted In One Single Sample Compartment So As To Maintain Same Conditions. (K) Validation: Instrument Should Have In Built Validation Tests 8) Software Specifications Required: (A) For Standalone Use Should Have: (A) Measurement Mode For Abs/%T At Particular Wavelength. (B) Measurement Mode For Wavelength Scan Over Entire Range For Abs & %T With Calculation Of Peak, Point Peak, Area & Derivative. (C) Measurement Mode For Quantitation I.E. Finding Of Concentration Of Unknown Samples With Plotting Of Calibration Curve Up To 3Rd Order With Standard Samples & Possible To Use The Same Next Time Without Requiring Standard. (D) Measurement Mode For Enzyme Kinetics With Activity Calculation. (E) Measurement Mode For Monitoring Sample Abs Over The Period Of Time. (F) Measurement Mode For Dna & Protein Quantitation. (B) For Pc Based Software Use Should Have: (A) Measurement Mode For Wavelength Scan Over Entire Range For Abs & %T With Detailed Data Processing Including Derivative, Log, Peak & Point Finding Etc. (B) Measurement Mode For Quantitation I.E. Finding Of Concentration Of Unknown Samples With Plotting Of Calibration Curve Up To 3Rd Order With Standard Samples & Possible To Use The Same Next Time Without Requiring Standard. (C) Measurement Mode For Enzyme Kinetics With Detailed Activity Calculation Using Various Kinetics Methods. (D) User Design Report Formatting With Various Type Of Pre-Defined Formatting. E. Multilevel Security And History. (E) Multilevel Security And History 9) Supplier Should Quote Instrument With 2 Pair Of Quartz Cell.

Key Value

Document Fees
INR 1500 /-
EMD
INR 12500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: TENDER FOR SUPPLY OF LABORATORY EQUIPMENTS & INSTRUMENTS
Sl. No. Item Description
1Double Beam UV – VISIBLE Spectrophotometer: 1) Instrument should be possible to use standalone with USB pen drive support for data storage. 2) Standalone instrument should be able to connect to printer with USB port. 3) Standalone instrument should have LCD display of minimum 125 x 90mm size. 4) Instrument should be able to use with PC with latest Windows -7 compatible instrument software. 5) Instrument control PC software compatible with Windows-7 should be supplied along with the instrument. 6) Instrument should have Lamp Hour usage monitoring with display of Lamp hours consumed. 7) Hardware specifications required: (a) Wavelength Range: 190nm to 1100nm (b) Monochromator: Blazed holographic grating with Crenzy Turner Mountings. (c) Spectral Bandwidth: 1nm over entire range (d) Wavelength accuracy: +/-0.3nm over entire range (e) Wavelength repeatability: +/- 0.1nm. (f) Light source: Separate Deuterium and tungsten lamp for UV and VIS range (g) Lamp Changeover: Automatic and user selectable lamp changeover between UV to visible Range (h) Noise level: less than 0.00005Abs. (i) Detector: Silicon Photodiode. (j) Sample Compartment: Sample & Reference cells should be mounted in one single sample compartment so as to maintain same conditions. (k) Validation: Instrument should have in built validation tests 8) Software specifications required: (A) For Standalone Use Should have: (a) Measurement Mode for Abs/%T at particular wavelength. (b) Measurement Mode for Wavelength scan over entire range for Abs & %T with calculation of Peak, Point Peak, Area & Derivative. (c) Measurement Mode for Quantitation i.e. finding of concentration of unknown samples with plotting of calibration curve up to 3rd order with standard samples & possible to use the same next time without requiring standard. (d) Measurement Mode for enzyme Kinetics with activity calculation. (e) Measurement Mode for monitoring sample Abs over the period of time. (f) Measurement Mode for DNA & Protein Quantitation. (B) For PC based software Use Should have: (a) Measurement mode for Wavelength scan over entire range for Abs & %T with detailed data processing including Derivative, Log, Peak & Point finding etc. (b) Measurement Mode for Quantitation i.e. finding of concentration of unknown samples with plotting of calibration curve up to 3rd order with standard samples & possible to use the same next time without requiring standard. (c) Measurement Mode for enzyme Kinetics with detailed activity calculation using various Kinetics methods. (d) User design report formatting with various type of pre-defined formatting. e. multilevel security and history. (e) multilevel security and history 9) Supplier should quote instrument with 2 pair of Quartz cell.