}

Tender For Construction Of Recreation Facilities At Cyberpark Kozhikode., kozhikode-Kerala

Kerala State It Infrastructure Limited has published Tender For Construction Of Recreation Facilities At Cyberpark Kozhikode.. Submission Date for this Tender is 04-01-2023. Civil Work Tenders in kozhikode Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

35115166
Corrigendum : Tender For Construction Of Recreation Facilities At Cyberpark Kozhikode.
Open Tender
Indian
Kerala
kozhikode
04-01-2023

Tender Details

Construction Of Recreation Facilities At Cyberpark Kozhikode. Work Include The Construction Of Recreation Facilities, Which Includes Foot Ball Turf, Badminton Court, Basketball Court And Associated Works.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Dec-2022 Date Corrigendum Date 27-12-2022
2 27-Dec-2022 Date Corrigendum-2 Date 04-01-2023
3 27-Dec-2022 Change in specification Technical Bid 04-01-2023

Key Value

Document Fees
INR 5900 /-
EMD
INR 50000.0 /-
Tender Value
INR 1.69 Crore /-

BOQ Items

Work Name : Construction of Recreation Facilities at Cyberpark Kozhikode
Sl. No. Item Description
1CIVIL WORKS
22.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
32.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removingthe roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth
42.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removingthe roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth
52.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removingthe roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth
62.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
74.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
87.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
92.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
1050.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
115.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
12od244692/2022_2023 : Fixed Basketball Poles<br>"*Pole will Made 17 CM (6"") Round Pipe<br>*Available in 2.2 Mtr Extn.<br>*Acrylic Board Thickness - 20 MM (Imported Quality), Size of Board - 180cm x 105cm<br>*Dunking Ring<br>*Quality Net<br>*Epoxy Painted"<br>
13od255637/2022_2023 : * Made of 40mm Round / Square MS Pipe <br>Badminton Pole<br>* Approx weight- 160 kgs per pair<br>* Garware Tournament quality Net - UV Treated<br>* 1 Year against manufacturing defect for poles(Consumable item e.g. Net will not be covered under warranty)
1416.75 : Providing and laying C.C pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewateringprocess and finally finished by floating brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge ( The panel shuttering work shall be paid for separately)
1516.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30
1616.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
1716.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ).( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)
1822.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
195.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
205.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
215.37.2 : Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level
2210.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
2312.1.1 : Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m2
2413.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
2513.11 : 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 ( 1 cement : 6 fine sand).
268.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
2711.39 : Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
282.35.3.1 : Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
2913.85.3 : Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre
3013.48A.1 : Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
3113.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
3213.62.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to givean even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .
33od255627/2022_2023 : UPVC DOORS AND VENTILATORS<br>Providing and fixing UPVC Factory Made ,white/Yellow colour casement /Sliding window, Louvers and door made of extruded profiles.Profiles of frames and sash will be mitered cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc. making arrangments for fixing of hardware,EPDM gasket,1.2 & plus mn,0.2 mm thick galvanised steel profile to be incldued in required profile ,frame will be fixed to the wall with 8 mm x 100 mm long fasteners , all complete as per direction of Engineer in Charge ,The rate is inclusive of 6 mm Galzing, Louvers,Loks,Hardware hinges,handles and fiting etc.
34od244536/2022_2023 : Supply of FIFA Certified Soccer Turf 50 MM Vmax Series Grass<br>"Supply & Installation of Sports Artificial Turf from FIFA Preferred Manufacturer having Pile Height of 50 MM with following construction of Yarn, Carpet, backing, CompositionPE, Structure Venus (Mono) & Fibrillated, Dtex 17500, Tape thickness 260&90μm (490 μm whole fibre), Tape width 1.25&6mm <br>Pile height 50mm±1mm, Gauge 5/8inch, Stitches per 10cm 13±1, Stitches per m2 8190±10%, Total yarn weight 1602g/ sqm ±10%, Primary backing PP + polyester fiber Mesh scrim inlay,Secondary backing PU, Total carpet weight 3002g/sqm ±10%, Infilling of Silica sand at the ratio of 30 kg/m2 & SBR Granules at the ratio of 7 kg/m2 Infill as FIFA standard. <br>Installation of Turf should be done using a seam tape & suitable PU adhesive. Adhesive TDS should match the following basic properties:<br>Colour & Form : Grass- green paste, Characteristics: 2 component, polyurethane – reaction adhesive for outdoor use, Specific Gravity : 1480 g/litre, Viscosity: Thixotropic, Solids: 100%, Application: Notched trowel or by suitable machine for applying to Seaming Tape.
35od244537/2022_2023 : Gravel Sub base<br>Construction of gravel sub- base by Providing• Preparing the slope & levelling using Auto Level• Compaction of sub-soil with 6-8 Ton Rollers• Weedicide Treatment of Land• Supply and Placing of Geo textile Separation Barrier tocover the entire field including the edges• Providing and laying of perforated PVC drain.Heavy Duty of 150mm dia with staggered perforations. Pipe would be placed on both sides of the drain.• Pipes would be placed on PCC Soling Base• Providing and laying of compacted upto 125mm thick with 40-23-20-12mm mixed metal Stone to form a contour and elevations to the desired level as per Drawings• Providing and laying of compacted upto 25mm thick with 6mm metal stone mixed with Grit• Drain Chamber to be constructed as per site requirement
36od244538/2022_2023 : 20 feet high Nylon Fencing for Football Pitch (6mtr high) Net: &;*Garware make;*Mesh Size 2 Inch x 2 inch, 2.5mm Thickt;*Tying Rope Size - 4mm (garware make).;*Color Green/Black.;*UV Resistant<br>*20 Feet High fencing, in-situ stitching will be performed t;Poles:;* 72 X 72 square mm MS pipes with 3.2mm guage for Vertical element and50 by 50 square mm pipes with 2.6mm guage for Horizontal element.;* Shape - Square;* 1 coat Primer ; 2 coat Enamel painted (Buss Green Color) ;
37od244540/2022_2023 : Movable Goal Post;*Made with branded high-quality MS Steel Pipe in 4"" Dia & Branded Epoxy Paint.;*Rust & Corrosion Free ;*Zero Vibration;*Size : 24 Feet x 8 Feet*Back Support of 1.5*The Poles Comprise wheels which make it easy to move
3813.52.2 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
39PLUMBING WORKS
4017.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
4117.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brass pillar taps
42od253815/2022_2023 : Supply andInstallation of PVC Bottle Trap
43od253816/2022_2023 : Supply andInstallation of SS Pillar Tap.
4417.4.1 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern
45od253442/2022_2023 : Supply and installation of angle cock with wall flange
46od253578/2022_2023 : Supply andInstallation of SS Health Faucet with Flexible Hose and its Holder
47od253810/2022_2023 : Supply andInstallation of site 20mm dia C.P brass Concealed and Exposed part ofStop Cock including cutting and making good the wall wherever required
48od253811/2022_2023 : Supply andInstallation of site 15mm dia C.P brassBib tap/hose connector with wall flange including cutting and making good the wall wherever required
49od253812/2022_2023 : Supply, Installation,testing and commission of valves stated as follows with all supports, fixing and fittingas specified and shown on drawings and complying to relevent standards<br>20mm dia section Brass Valve<br>
50od253813/2022_2023 : Supply, Installation,testing and commission of valves stated as follows with all supports, fixing and fittingas specified and shown on drawings and complying to relevent standards<br>25mm dia section Brass Valve<br>
51od254131/2022_2023 : Supply andInstallation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness(4kg/cm2)<br>40mm OD Waste Piping
52od254132/2022_2023 : Supply andInstallation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness(4kg/cm2)<br>50mm OD Waste Piping
53od254133/2022_2023 : Supply andInstallation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness(4kg/cm2)<br>75mm OD Waste Piping
54od254134/2022_2023 : Supply andInstallation of Lead free PVC-U pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness(4kg/cm2)<br>110mm OD Soil Piping
55od254135/2022_2023 : Supply andInstallation of Lead free UPVC SWR Type B pasted pipe using Solvent Cement ISI Marked [As per IS 13592] with Heavy duty ISI Marked PVC fittings through trench having upto a depth of 1mtr/as per site condition and to make corresponding slope hence complete. [Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness<br>110mm OD Waste Piping
56od254136/2022_2023 : Supply andInstallation of Lead free UPVC SWR Type B pasted pipe using Solvent Cement ISI Marked [As per IS 13592] with Heavy duty ISI Marked PVC fittings through trench having upto a depth of 1mtr/as per site condition and to make corresponding slope hence complete. [Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness<br>110mm OD Soil Piping
57od254137/2022_2023 : Supply andInstallation of Lead free UPVC SWR Type B pasted pipe using Solvent Cement ISI Marked [As per IS 13592] with Heavy duty ISI Marked PVC fittings through trench having upto a depth of 1mtr/as per site condition and to make corresponding slope hence complete. [Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness<br>75mm OD Waste Piping
58od253368/2022_2023 : Supply andInstallation of 125x125mm CPStainless Steel Gratings with Cockroach Protection for multi inlet floor trap.
59od253371/2022_2023 : Supply and Installing at site UPVC multi inlet traps and outlet connections to pipes using solvent cement complete as required for floor drains.<br><br>floor trap 110x75x50/40mm
60od253819/2022_2023 : Supply and Labour for Installing at site Open UPVC Lead Free ASTM Schedule 80 Pipes (Equivalent Standard Size) with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings suitable for the working pressure. Supporting exposed pipes using cement mortar at 60 cm intervals above terrace floor. Hydrostatic Testing of the Pipes using 10KG/cm2 test pressure for specified time period25mm Nominal Dia ASTM
61od253820/2022_2023 : Supply and Labour for Installing at site Concealed/openUPVC ASTM Schedule 80 Pipe ( Equivalent Standard Size) with all accessories like bends,y's etcfor Water supply Joined using Solvent Cement fittingssuitable for the working pressure. Inside walls, ceiling, concrete... etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period <br>20mm Nominal Dia
62od253821/2022_2023 : Supply and Labour for Installation at site Concealed/openUPVC ASTM Schedule 80 Pipes of Equivalent Standard Size with all accessories like bends,y's etcfor Water supply Joined using Solvent Cement fittings suitable for the working pressure. Chasing of the walls, duct, concrete etc. as required, replastering and refinishing using Cement Plaster 1:3 mix [Cement : Coarse sand].Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period<br> 25mm Nominal Dia ASTM
63od253822/2022_2023 : MANHOLE COVER<br>Supply and Labour for Installation ,testing & commisssioning of ISI marked FRP manhole cover and frame of (10 tonwithstanding capacity) conforming to the latest relevant IS specifications.<br><br>Size: 45cm x 45cm
64od253823/2022_2023 : MANHOLE <br>Supply and Labour for Installation,testing and commissioning of PVC type Manholes, valvechamber, sandtrap etc.. with suitable PCC around it with fit and finish and including escavation,backfilling,disposel, waterproofing etc upto 1 mtr depth all in accordance with the drawing ,specification and relevant standards. and its Cover with suitable frame and accessories<br>355mm base with suitable riser 110mm IN and 110mm OUT<br>(All civil Works are under Contractors Scope)<br>Size: 60cm x 60cm
65od253824/2022_2023 : Supply and Installing and Leveling Pipe Supports Fabricated from GI Slotted Rails / Channels of corresponding as per the site condition with suitable for carrying the operating weight of pipe and the fluids, 12mm Dia GI Adjustable Threaded Rods and Anchor Fasteners on wall, U clamps etc. as appropriate. <br>30cm width with 100cm interval
66od253825/2022_2023 : Labour charges for core cutting of slabs/beam for pipes of following sizes and include filling the gap with waterproof material and hence complete.<br>110 mm dia
67od253826/2022_2023 : Labour charges for core cutting of slabs/beam for pipes of following sizes and include filling the gap with waterproof material and hence complete.<br>75mm dia
68od253830/2022_2023 : Supply andInstallation of Robe Hook
69od253831/2022_2023 : Supply and Labour for Installation of Soap Dispenser
70od253832/2022_2023 : Supply andInstallation of water level float switch system for water level controlling
71od253833/2022_2023 : Supply and Installation of Ready made Septic tank(2000 ltr) including excavation works and providing leach pit of 1000 ltr.
72od253834/2022_2023 : Supply and installation of PVC water Tank of capacity 1000 litre with necessary fittings
73ELECTRICAL WORKS
7490.2.1.1 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single Control light point with 6A, plate ceiling rose - Short point
75Supply, installation testing and commissioning of pre-wired fluorescent fittings of all types complete with all accessories and fluorescent lamps etc. directly on wall or ceiling with Suitable size PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections as required.
7690.10.1.4 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 4 module moulded plastic box on surface
7790.10.3.17 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 6A universal socket
781.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
792.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
802.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
812.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
822.10.2 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
832.11 : Supplying and fixing single pole blanking plate inthe existing MCB DB complete etc. as required.
842.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
852.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
8690.12.7.15 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3 core 16 sq mm with factory made clamp
879.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)
8890.12.1.13 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3 core 6 sq mm
899.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
90od255458/2022_2023 : FOOTBALL TURF LED LIGHTING *Type of light-150 watts LED flood light.*Aluminium Die casting used.;*tuffen or tempered glass.*IP65(Water &; weather proof) Drivers & choke used.t;*Driver 440 volt protections;* Drivers at 300 Volt cutoff.;*Surge protection device (SPD) used.*Make:Wipro/Philips/equivalent&*2TC heat sink compound used.*Suppy & Installation of 150 Watts LED Lights On the existing fencing Structure.;*including 2.5 sqmm 3 core wire (coil) which should run on the fencing Poles with Conduits & wiring shall be underground untill Distribution Board.
91od255459/2022_2023 : BASKET BALL COURT LED LIGHTING.# 4 Lights on each MS round pole, Total 4 MS Light Poles of 20 ft height from ground level with 150 watts LED flood light;# Aluminium Die casting used, Tempered glass ;# IP65 (Water & weather proof) Drivers & choke used with Driver 440 volt protections Make:Wipro/Philips/Equivalent 150mm outer Dia X 3mm Thickness MS Base Pipe of Height 20Ft. 125mm outer Dia X 3mm Thickness MS Top Pipe of Height 4 Ft. 4 Feet Grouted Inside & 20 Ft Clear Height from the Subbase (Total Height of round Pole is 24Ft) and Square Pipe of 1 feet Ribs to be welded on either side of Pole to Form ladder System along with Resting Stand shall be provided on Top of PolewithExcavation, Concrete Filling & Grouting of Poles on marked area Junction Box Shall be provided on bottom of Poles 2 Coat primer andEpoxypainting to be done with Proper uniform finish Inclusive of transportation Charges to site MS Pole Erection
92od255460/2022_2023 : BADMINTON COURT LED LIGHTING*108 Watts LED Diffused Light &*CCT-6500k;*Total lumen(white)-10800*Voltage Input- 140 to 280V&*Voltage range- 70 to 90 VDC &;*Led chip- Bridgelux 0.2W(LM 80). ;1200mmX190mmX30mm;Aluminium base/PCdiffuser,powder coated MS sheet in stand.;Weight- 2.3 Kgs;*Suppy; Installation of 108 Watts LED Difused Lights.;*including 2.5 sqmm 3 core wire (coil) whichshould run on the fencing Poles with Conduits & wiring shall be underground untill Distribution Board.
9390.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
9490.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip
95od255433/2022_2023 : Pipe earth stations<br>Supply and Labour charges for Providing efficient pipe earth stations using 38 mm dia 2.5 m long GI pipe electrode, filling salt sand and charcoal, construction of earth chamber and covering with heavy duty cast iron cover hinged to cast iron frame, including excavation of earth pit.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail