Tender For Others-Drw 2022- Cwss To Nattika Firka- Renovation Of Pump House At Mathilakam - Electrical Repair Works At Illikkal Pump House -Drw 2022- Cwss To Nattika Firka- Rennovation Of Pump House At Mathilakam - Electrical Repair Works At Illikkal Pump
Tender Overview
Project Description
Others-Drw 2022- Cwss To Nattika Firka- Renovation Of Pump House At Mathilakam - Electrical Repair Works At Illikkal Pump House -Drw 2022- Cwss To Nattika Firka- Rennovation Of Pump House At Mathilakam - Electrical Repair Works At Illikkal Pump House-General Civil Work
BOQ
| Sl. No. | Item Description |
| 1 | Renovation of Existing raw water pump house at Illikkal - Painting the electro mechanical components |
| 2 | 14.46:Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 3 | 13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 4 | Standardisation of Electrical Installation - Rewiring the control room of Illikkal Raw water pump house and additional electrification the pump house |
| 5 | OD72726/2022-2023:90.2.1.1 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliantmodular accessories). |
| 6 | OD72727/2022-2023:90.2.1.6 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliantmodular accessories). |
| 7 | OD72728/2022-2023:90.2.1.4 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colourwashing etc. complete. All the terminations in the switchboards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliantmodular accessories). |
| 8 | OD72729/2022-2023:90.3.22.4 Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. |
| 9 | OD72730/2022-2023::90.2.1.21 Supply and wiring points according to IS 732-1989 using rigid PVC conduit ofminimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming toIS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providingswitch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular typefront plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colourwashing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall bedrawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliantmodular accessories). |
| 10 | OD72731/2022-2023:90.2.1.7 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliantmodular accessories). |
| 11 | OD72732/2022-2023:90.3.23.5.4 Surface mounting decorative fluorescent tube light fitting complete with lamp with complete accessories duly wired up for use on 230 V AC . |
| 12 | OD72733/2022-2023:90.15.3.1 Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters |
| 13 | OD72734/2022-2023:90.15.4.7 Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 14 | OD72735/2022-2023:1176 Surface mounting 20 W LED Batten with output of 2000 lumen for use on230 V AC supplysupply |
| 15 | OD72736/2022-2023:90.3.23.6 Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet .5mm thick with all accessories and lamps etc. suspended from ceiling using 2 nos steel chain (16 SWG or nearest available size) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. |
| 16 | OD72737/2022-2023:90.4.3 Conveyance installation testing and commissioning ceiling fan of all sizes using standard accessories excluding resistance type regulator wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or extending the original wiring etc. as required. |
| 17 | OD72738/2022-2023:90.4.5.2 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. |
| 18 | OD72901/2022-2023:90.3.10 Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring andgiving connection etc. as required. |
| 19 | OD72740/2022-2023:90.3.18.1 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required. |
| 20 | OD72741/2022-2023:90.15.4.1 Supply Conveyance, installation,testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with powerfactor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 21 | OD72742/2022-2023:90.1.1.1 Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re- inforcement etc. as required. |
| 22 | OD72744/2022-2023:90.6.5.9 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 23 | OD72746/2022-2023:90.6.5.5 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. |
| 24 | OD72745/2022-2023:90.11.1.20 Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper/brass busbar, neutrallink, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required |
| 25 | OD72747/2022-2023:90.16.2.5 Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required. |
| 26 | OD72748/2022-2023:2.12.2 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 27 | OD72749/2022-2023:2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 28 | OD72759/2022-2023:2.17 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 29 | OD72758/2022-2023:2.10.3 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 30 | OD72757/2022-2023:1.3 Supplying and fixing metal box of 180mm X 100mmX 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. |
| 31 | OD72756/2022-2023:1.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). |
| 32 | OD72755/2022-2023:1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,connection etc. as required. (For light plugs to be used in non residential buildings). |
| 33 | OD72754/2022-2023:90.9.2.13 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. |
| 34 | OD72753/2022-2023:90.9.2.15 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cuttingthe wall and making good the damages in case of recessed installation as required. |
| 35 | OD72752/2022-2023:90.10.1.4 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) |
| 36 | OD72751/2022-2023:90.10.1.3 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) |
| 37 | OD72750/2022-2023:90.10.1.7 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) |
| 38 | OD72761/2022-2023:90.10.3.22 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) |
| 39 | OD72762/2022-2023:90.10.3.32 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) |
| 40 | OD72763/2022-2023:90.10.3.33 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) |
| 41 | OD72773/2022-2023:1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). - (8 module) |
| 42 | OD72772/2022-2023:1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). - (12 module) |
| 43 | OD72771/2022-2023:90.10.3.14 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) |
| 44 | OD72770/2022-2023:90.10.3.24 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) |
| 45 | OD72769/2022-2023:90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required |
| 46 | OD72768/2022-2023:90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required |
| 47 | OD72767/2022-2023:90.16.1.5 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required |
| 48 | OD72766/2022-2023:Supplying and fixing 100 W step type fan regulator 2 M |
| 49 | OD72765/2022-2023:Supplying and drawing 2.00 mm copper conductor (14SWG) along with wiring cables and giving connection as required. |
| 50 | OD72764/2022-2023:Supplying and drawing 3.15 mm copper conductor (10SWG) along with wiring cables and giving connection as required. |
| 51 | OD72922/2022-2023:Supplying and providing earth strip including cutting, drilling necessary holes on 25 x3 mm copper strip tinned at the points of contacts and giving earth connections as required |
| 52 | OD72923/2022-2023:Supply of superior quality copper earth socket for No.10 SWG copper earth conductor |
| 53 | OD72929/2022-2023:Supply of superior quality copper earth socket for No.14 SWG copper earth conductor |
| 54 | OD72928/2022-2023:Supplying and providing 25x6 mm Brass Bolt and nut with washers on the earth bus as required including drilling necessary holes as required. |
| 55 | OD72968/2022-2023:Supplying and providing 25x3 mm Brass Bolt and nut with washers on the earth bus asrequired including drilling necessary holes as required. |
| 56 | OD72970/2022-2023:Supply and providing plate earthing as per IS - 3043 with 600x600x6.3 mm G.I/ C.I earth plate, 20 mmG.I watering pipe fixed to the earth plate with 20 X 3 mm G.I clamps, G.I funnel with weld mesh, filling required quantity of charcol including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm brokenstone ( 10 cm thick) brick work in cement mortar 1:4, 12 mm thick ( the finished inside dimension shall be 300x300x300 mm ) but excluding test joint, earth continuity conductor to the plate and covering at the top. |
| 57 | OD72971/2022-2023:Supply and providing 300x300x10 mm Cast iron gully trap with covering |
| 58 | OD72972/2022-2023:Supply and providing test joint for the earthing system using 2 Nos of 2x25x3 mm tinned copper strip including cutting and bending to the shape, drilling necessary holes and fixed to the watering pipe etc as required |
| 59 | OD72991/2022-2023:Supplying and fitting 11 KV Lightening arrester on Transformer structure and giving connections |
| 60 | OD72992/2022-2023:Supplying and drawing 4.75 mm Copper conducted (No. 6 SWG ) for earthing the Lightning Arrester |
| 61 | OD72995/2022-2023:Supplying and laying 4.75 mm copper conductor (No.6 SWG) laid 0.6 M below ground level including excavating trench of suitable size and refilling as required for earthing the lightening Arrester |
| 62 | Supply of safety personal protection equipment for operators and workers at WTP at Vellani Plant , Illikkal Pump House |
| 63 | OD73054/2022-2023:Supply of First Aid Kit, Class A |
| 64 | OD73053/2022-2023:supply of CO2 Fire Extinguisher 4.5 Kg Cylinder Capacity With ISI Mark, CCEO/PESO Certified, Operating Temp: -20C to 60C, Fire Rating of 55 B of IS 15683:2018 ISI Marked |
| 65 | OD73052/2022-2023:Supply and providing following safety items. 4 Nos. fire bucket with floor mounting self stand type |
| 66 | OD73051/2022-2023:Supply and providing following safety items.<br>a.6mm thick rubber mat 0.9m wide 1.8m long (ISI marked) |
| 67 | OD73050/2022-2023:Supply of safety equipment - Gum boots |
| 68 | OD73049/2022-2023:Supply of safety equipments -Reflective jackets |
| 69 | OD73048/2022-2023:supply of safety equipment -Gloves for handling chemicals for WTP |
| 70 | OD73047/2022-2023:supply of Rechargeable torch for WTP /pump house/GL tank |
| 71 | OD73046/2022-2023:supply of safety equipment - Helmet for WTP |
| 72 | OD73045/2022-2023:supply of safety equipment - Googles for WTP |
| 73 | OD73044/2022-2023:Supply of safety equipment - Respiratory masks |
| 74 | Renovation of Existing 20MLD water treatment palnt at Vellani- Painting the electro mechanical components. |
| 75 | 14.46:Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 76 | 13.48.2:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture |
| 77 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 78 | OD73079/2022-2023:Supplying & fixing new Flash mixing systems 2 HP motor ,gear box & SS paddles |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender