Construction Of Road Frombilashipara Gaon Near Amtol To Bilashipara Pather Pmgsy Road Including Routine Maintanence For 4 Years Under Mukhya Mantrir Paki Path Nirman Aachani For The Year 2022-23
Tender Value
1.60 Crore
Estimated cost
Bid Submission
20 Dec 2022
0 days left
EMD
3.21 Lakhs
Bank guarantee accepted
Document Fee
3210
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
sorbhog → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Road Frombilashipara Gaon Near Amtol To Bilashipara Pather Pmgsy Road Including Routine Maintanence For 4 Years Under Mukhya Mantrir Paki Path Nirman Aachani For The Year 2022-23
BOQ
| Sl. No. | Item Description |
| 1 | Clearing and grubbing of road land including up rooting rank vegetation grass,bush, shurbs saplings and trees of girth upto 300mm removal of stumps of trees cut earlier and disposal of unseviceable materials & stacking of serviceable material to be used or auctioned, upto a lead of 1000m including removal & disposal of top organic soil not exceeding 150mm in thickness.(I) By manual Means- (a) In area of non thorny jungle |
| 2 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantledmaterial, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.I. By Manual Means(b) Cement Concrete |
| 3 | Construction of embankment with material obtained from borrow pits, construction of embankment with approved materials obtained from borrow pits with a lift up to 1.5m, transporating to site, spreading, grading to required slope and compacting to meet required of tables 300.1 and 300.2 with a lead upto 1000m as per technical specification clause. (a) Private Land |
| 4 | Construction of sub-grade and earthen shouldersconstruction of sub grade and earthen shoulders with approved materials obtained from borrow pits with all lifts and leads, transporating to site, spreading, grading to required slope and compacting to meet required of table 300.2 with lead upto 1000m as per technical specification clause.(a) Private Land |
| 5 | (A) By mix in place Method -Construction of granular sub base by providing well graded material, spreading in uniform layers with motor grader on prepare surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification clause 401. (ii) For Grading Material (Gr-II) |
| 6 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.A) By Manual MeansUsing stone screening Type-B 11.2 mm for Gr.III |
| 7 | Providingand laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete including carriage.(i) Including Edge Restrain/Edge Block |
| 8 | Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm equilateral triangle |
| 9 | Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm circular |
| 10 | Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 800mm x 600mm rectangular |
| 11 | Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges.The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level.The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube.All M.S. will be stove enameled on both sides.Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 12 | Single bamboo spur and palisading of whole 2nd class bamboo (jati or Bethua) 65 mm to 75 mm dia and closely packed & driven, including fitting, fixing with half bamboo kamis horrizontally in three rows with cane or tying wire complete and struts 1500 mm apart longitudinally and providing brush wood as per drawing and technical specifications Clause 1302.5ii Driven at least 900 mm below ground and 900 mm above ground on average from Ch 1150.00 M to 1200.00 M |
| 13 | Cpnstruction of 4.00 M Slab CulvertE/Work in excavation for structures as per drawing and technical specification, clause 305-1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m., dressing sides and bottom and backfilling in trenches with excavated suitable material.1. Ordinary soil |
| 14 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, 1202 & 1203.A. With Crushed stone.I. PCC grade M10Nominal mix 1:3:6 |
| 15 | Plain/reinforced cement concrete in Sub Structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. A. With Crushed Stone I. P.C.C grade M 15I. Nominal mix (1:2.5:5) |
| 16 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specification Clause 800, 1205.4 and 1205.5.A. With crushed stoneI. RCC grade M 20(iii) For design mix RCC M20a) Height upto 5.0 m. |
| 17 | Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and Technical Specification Clause 800 and 1206.3.A. With crushed stone |
| 18 | Providing weep wholes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of the structures with slope of 1(V) : 20(H) towards drawing face complete as per drawing and Technical Specification Clause 614, 709, 1204.3.7. |
| 19 | Drainage spouts complete as per drawing and Technical Specification Clause 1209. |
| 20 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8 |
| 21 | Supplying, fitting and placing TMT bar reinforcement (Fe 500) in sub structure complete as per drawing and Technical Specification Clauses 1002, 1005, 1010 & 1202. |
| 22 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 23 | Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301 |
| 24 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302(I) Stone/ Boulder |
| 25 | Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 |
| 26 | Cpnstruction of 6.00 M Slab CulvertE/Work in excavation for structures as per drawing and technical specification, clause 305-1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m., dressing sides and bottom and backfilling in trenches with excavated suitable material.1. Ordinary soil |
| 27 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, 1202 & 1203.A. With Crushed stone.I. PCC grade M10Nominal mix 1:3:6 |
| 28 | Plain/reinforced cement concrete in Sub Structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. A. With Crushed Stone I. P.C.C grade M 15I. Nominal mix (1:2.5:5) |
| 29 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specification Clause 800, 1205.4 and 1205.5.A. With crushed stoneI. RCC grade M 20(iii) For design mix RCC M20a) Height upto 5.0 m. |
| 30 | Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and Technical Specification Clause 800 and 1206.3.A. With crushed stone |
| 31 | Providing weep wholes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of the structures with slope of 1(V) : 20(H) towards drawing face complete as per drawing and Technical Specification Clause 614, 709, 1204.3.7. |
| 32 | Drainage spouts complete as per drawing and Technical Specification Clause 1209. |
| 33 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8 |
| 34 | Supplying, fitting and placing TMT bar reinforcement (Fe 500) in sub structure complete as per drawing and Technical Specification Clauses 1002, 1005, 1010 & 1202. |
| 35 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 36 | Shifting of utilities as per site requirement in consultation with the concerning department |
AI Tender Summary
Tender Timeline
Dec 03, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedDec 20, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 21, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender