Tender For Repair And Maintenance Of Ceiling Fans, Air Circulators, Exhaust Fans, Geyser And Solar Water Heater At Zone-Iii Area Under Ge (S) Jaipur, jaipur-Rajasthan

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Ceiling Fans, Air Circulators, Exhaust Fans, Geyser And Solar Water Heater At Zone-Iii Area Under Ge (S) Jaipur. Submission Date for this Tender is 26-12-2022. Solar Heater Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

35080943
Corrigendum : Tender For Repair And Maintenance Of Ceiling Fans, Air Circulators, Exhaust Fans, Geyser And Solar Water Heater At Zone-Iii Area Under Ge (S) Jaipur
Open Tender
Indian
Rajasthan
jaipur
26-12-2022

Tender Details

Tender For Repair And maintenance Of Ceiling Fans, Air Circulators, Exhaust Fans, Geyser And Solar Water Heater At Zone-Iii Area Under Ge (S) Jaipur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINT OF CEILING FANS, AIR CIRCULATORS, EXHAUST FANS, GEYSER AND SOLAR WATER HEATER AT ZONE – III AREA UNDER GE (S) JAIPUR
Sl. No. Item Description
1Taking down carefully existing storage type Geyser 25/50 litres capacity for repair complete overhauling including cleaning of geyser assembly inlet outlet pipe etc and re-fixing in position all as directed by Engineer-in-Charge. Note :- Replacement of parts will be measured & paid seperately under respective item.
2Cleaning and preparation of outer surface of Geysers 25 litres capacity and painting with two coats of white synthetic enamel paint as directed by Engineer-in-Charge.
3Cleaning and preparation of outer surface of Geysers 50 litres capacity and painting with two coats of white synthetic enamel paint as directed by Engineer-in-Charge.
4M&L for opening of geyser in position for carry out minor repair such as loose connection testing of thermostat, heating element, tightening of screws, PVC connection etc. Note :- Any item required to be replacement shall be measured and paid for separately as under :-
5S&F in replacement Stainless steel inner tank of capacity 25 Ltr.
6S&F in replacement Stainless steel inner tank of capacity 50 Ltr.
7S&F in replacement Glass wool/ rock wool for thermal insulation.
8S & F in replacement Outer tank madeof MS sheet powder coated suitable for 50 Ltrs.
9S & F in replacement Outer tank made of MS Sheet powder coated suitable for 25 Ltrs.
10Dismantling of bottom assemble and de-scaling with acid and wire mess brush cleaning and refixing the same.
11M & L in replacement PVC insulated and over all PVC sheathed copper conductor wire of size 2.5 Sqmm x 3 core, Lead wire heavy duty, ISI marked.
12M & L in replacement Plug top 3 pin, 15 Amp rating ISI.
13S & F in Replacement of heating element of capacity 1.5 KW ISI fixed complete.
14S & F in Replacement of heating element of capacity 2 KW ISI fixed complete.
15S & F in Replacement of heating element Clip on made of copper, capacity 2 KW ISI complete.
16Replacement of Geyser bottom assemblyof 7 hole/9 Hole/6 hole as per existing complete including, bolts and rubber gasket for 25/50 litres capacity Geysers as per requirement with the existing make which is to be replaced.
17M&L in repair for Pressure release safety valve for Geysers spring loaded suitable for 15mm pipe chromium plated.
18M&L in replacement of thermostat ISI marked of any make/ capacity of geyser.
19M&L in replacement of thermostat ISI marked suitable for geyser venus T105 type TBS or other make 16 A 250 Volt complete.
20M&L for replacement of thermostat ISI marked suitable for geyser which is to be replaced having 2 male terminals and round base complete.
21Replacement of neon indicator lamp round or rectangular type.
22M&L for replacement of PVC flexible connection inlet/outlet (hot and/or cold), high strength, impeccable finish, corrosion resistance 450mm long for geyser complete.
23M&L for replacement of PVC flexible connection inlet/outlet (hot and/or cold), high strength, impeccable finish, corrosion resistance 600mm long for geyser complete.
24S&F in repair tubes 15mm bore medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floors complete.
25S&F in reapir Angle stop valve of PTMT any colour high pressure screwed for iron pipe (Minimum weight 15mm-90gms) all as spacified and directed.
26S&F in reapir Bib taps , cast copper alloy with crutch of butter fly handle screwed down , screwed for iron pipe or for brass ferrule, fancy type and fixed of size 15 mm dia complete all as spacified and directed.
27Disconnecting electrical connection andwater connection and dismantling/ taking outGeyser of any make and capacity from any placeandinstallation, commissioning and testing to another location including grounting nut and bolts with washers or with fasteners and testing complete all asspecified and directedby Engineer-in Charge.
28M&L Point wiring in repair using approved colour coding as per IS, with stranded copper conductor2.5 Sq. mm (nominal area), single core, FRLS insulated, PVC insulated and unsheathed stranded cable 1100 volts grade, confirming to IS-694/ISI markedin and including PVC casing caping25mm wide, medium grade, ISI marked, with mild steel sunken boxes with earth dolly zink coatedand including mounting frame andover cover plate, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earthand connected FRLS cable 1100 V grade as continuous earth wire to earth dollyfor 3 pin switch socket outlet15Amp independent board complete all as specified and directed by Engineer in charge including taking out old with switch and sockets.
29Supply&.fix in repairSwitch Piano typetype 230/ 250V grade on top covers 16 Amp (catered in point wiring above)
30S & fixin repair Socket outlet multipurpose use, non shuttering/ non interlocking flush mounting type, 230/250 Volts grade on top covers16 Amp (catered in point wiring above).
31Repair to solar water heater Dismanlting & Descaling of solar collectors with acid (dilute)for solar water heater panel of 200 LPD as recommendedby manufacture cleaning and re-assembling complete and soldering to arrest leakage etc complete.
32Dismanlting & Descaling of solar collectors with acid (dilute)for solar water heater panel of 100 LPD as recommendedby manufacture cleaning and re-assembling complete and soldering to arrest leakage etc complete.
33Takinng down water inlet/outlet of solar collectors plate , disconnetion of mounting and dismantlling into parts and cutting inner copper tubes, removing the scaling from the chocked copper tube by drilling and scraping with hard metal rods including washing with acid(dilute) compete for solar panel 3 Nos suitable for 200 LPDhaving 6 Nos tubes in each panel, brazing with existig pipes after descaling complete including testing for leackage, if any and reassembling the same in the existing mountingas recommendedby manufacture cleaning and re-assembling complete and soldering to arrest leakage etc complete.
34Takinng down water inlet/outlet of solar collectors plate , disconnetion of mounting and dismantlling into parts and cutting inner copper tubes, removing the scaling from the chocked copper tube by drilling and scraping with hard metal rods including washing with acid(dilute) compete for solar panel 1 Nos suitable for 100 LPDhaving 6 Nos tubes, brazing with existig pipes after descaling complete including testing for leackage, if any and reassembling the same in the existing mountingas recommendedby manufacture cleaning and re-assembling complete and soldering to arrest leakage etc complete.
35Supply and replace hose pipe for hot and cold water as per existing
36Taking out U/S gate valve and supply and fixingof Gun metal gate valve 15mm dia ISI marked.
37Taking out U/S gate valve and supply and fixingof Gun metal gate valve 20mm dia ISI marked.
38Supply and replace U/S electric back up element 240 volt AC supply 3KW rating ISI marked including thermostate all as per sample.
39Supply and replace U/S electric back up element 240 volt AC supply 5 KW rating ISI marked including thermostate all as per sample.
40Taking out old rusted GI pipe including insulation and supply and fixing GI pipe 20 mm bore ISI marked medium grade complete with insulation comprising of glass wool, wiremesh overall aluminium cladingwith fixing steel screw 125mm center to center complete all as specified and as directed.
41Repair to leakage for existing solar heater panel of 200 LPD complete all as specified and as directed..
42Supply & replace following U/S item from sheet metal enclosure DBs complete 240 Volts, AC supply.
43(a) Metallic Plug top.
44(b) Metallic socket
45(c ) MCB 5 to 32 Amp, 10 KA,SP "C" Series
46S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 amp MCB 240V "c" series complete.
47S & F in repalacement of rusted Angle iron of size 40x40x5 mm for supporting Solar panels on roof top including welding and fixing with suitable nut bolts and washer complete all as specified and diercted
48M&L for PCC (1:2:4) type B-2 in cementconcrete for grouting agles in roof surface withusing 20 mm graded stone complete all as sepeceified and directed
49Taking down carefully existing ceiling fans/wall fans of any make and sizes from ceiling/wall ,cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and reassembling after replacement of rubber real,wall fan blade , wall fan bracket ,MS nuts and bolts , split/safety pins and fan connector including replacement of old existing flexible cord connected from ceiling rose to fan through down rod and refixing and rehanging the same in existing position complete all as specified and directed by Engineer in charge. Note :- Replacement of major parts will be measured & paid separately under relevent item of BOQ.
50M &L for dismantling of worn out/burnt out motar of ceiling fans 1200 mm sweep Fans/Wall fans 200/400 mm and re-winding the ceiling fan with the same size/gauge of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut , complete all as specified and directed by Engineer in charge
51All all as per serial item No 47 here in before but for Ceiling fans of 1400 mm sweep. Notes:for item 46 to 48 : - (a) Repairs under serial item No. 46 here in before shall be carried out at the site of work. Where as fans for repair under serial item no. 46 and 48 shall be issued to contractor and the same shall be returned by him after carrying out necessary repairs duly tested. (b) Rewinding under srl item no 47 & 48 shall be done with winding machine/licenced electrician. (c) Fans will be given to contractor underGate Pass in Lots of appx 50 Fans and the same shall be returned by contracter in 10 Days time after all repairs and painting as directed. Failing which the panelty for not receipt of repair fan in stipulated time shall be Rs 20 per fan per day. (d).Repair to ceiling fans will be carried out at MES Yards or its site. (e) Spares/parts like ball bearing, gun metal bush, capacitors and canopy required for repair/overhauling shall be measured and paid separately under relevant item of this schedule as supply only
52Supply in replacement of MS clamp for hanging of fan with nuts & bolts & locking pin suitable for ceiling fans of any make, type and size.
53Supply in replacement rubber reels suitable for ceiling fans of any make, type and size.
54Supply and fix in replacementfan regulator Piano type for ceiling fans of any make, type and size.
55Supply and fix in replacementCeiling cover Plate circular type for ceiling fans of any make, type and size.
56Taking down carefully existing exhaust fans / PVC Air Freshner Fans of any make and sizes from wall , cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and re assembling after replacement of split/safety pins, MS nuts and bolts , including replacement of old existing flexible cord connected from ceiling rose to fan and , refixingthe same in position complete all as specified and directed by Engineer in charge. Note:-Spares/parts like ball bearing, gun metal bush and capacitors required for repair/overhauling shall be measured and paid separately under relevant item of this schedule.
57M &L for dismantling of worn out/burnt out motar of Exhaust fans/ / PVC Air Freshner Fans 200 mm to 300 mmsweep and re-winding the exhaust fan with the same gauge/ size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, rusted nut ,bolt and washer complete all as specified and directed by Engineer in charge.
58M &L for dismantling all as per serial item No 54 here in before but for Exhaust fans of size above 300 mm but up to 450 mm sweep. Note Applicable for item no 53 to 55: - Repairs under serial item No.54 here in before shall be carried out at the site of work. Where as fans for repair under serial item No.54 and 55shall be issued to contractor and the same shall be returned by him after carrying out necessary repairs duly tested with in 10 days. Failing which the panelty for not receipt of repair fan in stipulated time shall be Rs 20 per fan per day. Supply of spare/parts will be paid as supply only under relvant item.
59Supply in replacement of ball bearing suitable for exhaust fans of size from 200 mm to 300 mm sweep.
60Supply in replacement of capacitors suitable for exhaust fans of size 300 mm to 450 mm sweep.
61Material and labour for preparation of old surfaces of Exhaust fan by scraping out old paint with the help of emery paper/ wire brush including filling the cavities and painting with two coats ofgrey paint for exhaust fansandexhaust fan louver over a coat of red oxide primer with the help of spray machine complete all as specified and directed at site .
62Supply and fix in replacement of louvers shutters complete with nuts, bolts and washers suitable for exhaust fans of size 250mm to 300 mm sweep complete all as specified and directed by Engineer in charge.
63All as per serial item No 59 here in before but for exhaust fans above of size 300 mm to 450 mm sweep complete all as specified and directed by Engineer in charge.
64Supply in replacement of worn out nuts and bolts for fixing of Exhaust fans including finishing the disturbed surface ofwall complete all as specified and directed by Engineer in charge.
65Supply in replacement for PVC insulated and over all PVC sheathed copper conductorwire of size 1.5 Sqmm x 3 core,flexible wireISI marked, for connection of fan from ceiling rose to fans complete all as specified and directed by Engineer in charge.
66M &L for hanging clamps with provission of hook made out of MS flatwith suitable size nut,bolt and washer complete all as specified and directed.
67M & L in repair for ceiling rose surface bakelite 65X50 mm, three terminal complete.
Disclaimer :