| 1 | INTERNAL ELECTRIFICATION WORKS |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Group C |
| 4 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single corecable etc. as required. |
| 5 | Wiring for 2 group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 7 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 8 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 9 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 11 | 16 Module |
| 12 | 8 Module |
| 13 | 6 Module |
| 14 | 4 Module |
| 15 | 1 or 2 Module |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 17 | 6 pin 15/16 A socket outlet |
| 18 | 15/16 A switch |
| 19 | Telephone socket outlet |
| 20 | LAN Socket Outlet |
| 21 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 22 | Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 23 | Supplying and fixing of 25mm Dia of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required. |
| 24 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 25 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required |
| 26 | Supply of 1200mm Ceiling Fan with standard down rod and all accessories. |
| 27 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 28 | Supply of 225mm Exhaust Fan with all accessories. |
| 29 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 30 | Upto 450 mm sweep |
| 31 | Supplying and fixing 6 way (4 + 18), Double doorhorizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 32 | Supplying and fixing 4 way (4 + 12), Double doorhorizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 33 | Supplying and fixing 63A, four pole, 415 V, RCCB 100mA in the existing DB complete with connections, testing and commissioning etc. as required. |
| 34 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 35 | Supply, fixing , testing and commissioning of single phase Vertical 15 Ltr Geyser working with 230V AC, 2K Wattage all as directed by Engineer in Charge. |
| 36 | Supply, Installation, Testing & Commissioning of the automated 10.5W Circular Slim recess mounted Downlighter with along with Remote. |
| 37 | Supply, Installation, Testing & Commissioning of the 20W Profile Lighting including all accessories. |
| 38 | Supply, Installation, Testing and Commissioning of LED Chandellier Fixture including all connections and as per engineer in charge. |
| 39 | Supply and fixing of Dish Antennas and LMBs etc., also provision of New DTH Connections with One Month free subscription with Minimum 10 channels etc., all as per the directions of Engineer - In- Charge. Complete |
| 40 | Supply, Installation, Testing and Commissioning of following LED Track Lights including necessary connections and complete |
| 41 | 12Watt Track Light |
| 42 | 7Watt Track Light |
| 43 | 4Way Outdoor Light |
| 44 | 2Way Outdoor Light |
| 45 | Mirror Lamps |
| 46 | Wooden type Mirror Lamps |
| 47 | Outdoor Wall Light |