| 1 | Part-A: Supply |
| 2 | Power Transformer |
| 3 | 50 MVA, 220/33KV, Three phase transformer including Bushing, accessories, first filling of oil, alongwith Online DGA and Fibre Optic Temperature Measurement System. |
| 4 | Nitrogen Injection Fire Prevention & extingusihing system for transformer |
| 5 | Oil Storage Tank |
| 6 | Oil sampling Bottle |
| 7 | 630KVA, 33/0.433KV, three phase transformer includign bushing, accessories and first filling of oil |
| 8 | 245kV GIS Equipments |
| 9 | 245KV,SF6 gas insulated transformer bay module each comprising of SF6 gas insulated circuit breaker, current transformer, two bus-bar disconnectors withgrounding switch, one disconnector with safety grounding switch, high speed fault making grounding switch, surge arrestors (216KV), SF6 gas monitoring system for complete bay, LCC, three 1-phase SF6 ducts and SF6/Oil Interface to connect to 220/33kV, 50 MVA transformer and accessories with GIS etc. to complete transformer bay module |
| 10 | 245KV,SF6 gas insulated feeder bay module each comprising of SF6 gas insulated circuit breaker, current transformer, two bus-bar disconnectors withgrounding switch, line disconnector with safety grounding switch, high speed fault making grounding switch, SF6 gas monitoring system for complete bay, LCC, three 1-phase SF6 ducts, SF6/Air termination and accessories with GIS etc. to complete feeder bay module. |
| 11 | 245KV, SF6 gas insulated, metal enclosedbus bars each enclosed in bus enclosures running along the length of the switchgear to interconnect each of circuit breaker bay module. Each bus-bar set shall be complete with voltage transformer complete with safety grounding switch. |
| 12 | 245KV, SF6 gas insulated bus coupler bay module comprising of SF6 gas insulated circuit breaker, current transformer, two disconnectors with safety grounding switches, SF6 gas monitoring system for complete bay, LCC etc. |
| 13 | 245kV AIS Equipments |
| 14 | 245 kV CVT with junction box |
| 15 | 245 kV Lightning Arrester with counter and leakage meter |
| 16 | 245 kV BPI |
| 17 | Miscellaneous Materials (Insulators Strings / Disc Insulators, Hardwares, Conductor, Bus-Bar materials, Cable Trays, Clamps, Connector including equipments connectors and all accessories etc. |
| 18 | 36KV GIS Equipments |
| 19 | 36KV,SF6 gas insulated feeder bay module / Panel each comprising of SF6 gas insulated Circuit Breaker, Current Transformers, Potential Transformers, Lightning Arresters, two bus-bar disconnectors one withgrounding switch& one without grounding switch, SF6 gas monitoring system for complete bay, control & protection along with associated equipment. Cable termination and accessories with GIS etc. for 33 KV outgoingline feeder bay module. |
| 20 | 36KV,SF6 gas insulated bus coupler bay module comprising of SF6 gas insulated circuit breaker, current transformer, two numbers of disconnectorswith earthing switch, SF6 gas monitoring system for complete bay, control & protection along with associated equipment. etc. |
| 21 | 36KV,SF6 gas insulated transformer bay module each comprising of SF6 gas insulated circuit breaker, current transformer, Lightning Arresters,two bus-bar disconnectors one withgrounding switch& one without grounding switch,SF6 gas monitoring system for complete bay, with cable termination, control & protection along with associated equipments. |
| 22 | 36KV, 3-phase or single phase encapsulated unit, SF6 gas insulated, metal enclosed bus-bars each enclosed in bus enclosures running along the length of the switchgear to interconnect each of cirucit breaker bay module. Each bus-bar set shall be complete with voltage transformers with safety grounging switch. |
| 23 | 36KV,SF6 gas insulated feeder bay module / Panel each comprising of SF6 gas insulated circuit breaker, current transformers, Potential Transformers, Lightning Arresters, two bus-bar disconnectors with grounding switch, SF6 gas monitoring system for complete bay, Cable termination and accessories with GIS etc. suitable for 630 KVA 33/0.4 KV station transformer, control units, control and protection along with associated equipment. |
| 24 | 36KV AIS Equipments |
| 25 | 33kV BPI |
| 26 | 33kV Lightning Arrester |
| 27 | 33 kV Air Break Switch |
| 28 | Complete substation automation system including hardware and software for the substation & remote control stations alongwith associated equipments as per Technical Specifications. |
| 29 | Bay Control Units |
| 30 | 220kV System |
| 31 | 33kV System |
| 32 | 220 KV Control and Relay panel |
| 33 | Circuit Breaker Control Panel |
| 34 | With Auto Reclose |
| 35 | With out Auto Reclose |
| 36 | Line Protection Panel (Main 1+Main 2) |
| 37 | Bus Bar Protection Panel |
| 38 | 220kVbus bar protection panel for Main-1 and Main-2 |
| 39 | Transformer Protection Panel (HV side) |
| 40 | PLCC for 220KV Line feeder |
| 41 | Line Traps |
| 42 | 2000A, 0.5 mH, 40 kA |
| 43 | Coupling device ( Phase to Phase ) |
| 44 | HF Cable |
| 45 | Carrier Equipment |
| 46 | for Speech + Protection 1 & 2 |
| 47 | for Speech + Data |
| 48 | Protection Coupler |
| 49 | Synchronizing Trolley |
| 50 | Time synchronisation equipment |
| 51 | Testing & Maintenance Equipment |
| 52 | Meggar 5 KV (Motorized) |
| 53 | Meggar 1 KV (Motorized) |
| 54 | Automatic capacitor and Tan Delta measuring kit |
| 55 | Digital Multi meter |
| 56 | Leakage tester (Tong type) |
| 57 | Selective level meter |
| 58 | Signal generator |
| 59 | Micro-ohm meter |
| 60 | Gapless zinc oxide LA tester |
| 61 | Oil BDV Kit 0-80 KV |
| 62 | Gas Evacuating and refilling Plant |
| 63 | Gas Leakge Monitor |
| 64 | Circuit Breaker Analyser |
| 65 | Portable Partial dischange monitoring system |
| 66 | Dew Point Meter |
| 67 | Battery Earth Fault Locator |
| 68 | Primary Injection Set 1000 Amp |
| 69 | Relay Test Kit |
| 70 | Gas Mask |
| 71 | D-Spanner set (Insulated) |
| 72 | Ring-Spanner set (Insulated) |
| 73 | Torque wrench set |
| 74 | Insulating gloves |
| 75 | Helmets |
| 76 | Spliced ladders 5mtr. |
| 77 | Spliced ladders 10mtr. |
| 78 | Spliced ladders 20mtr. |
| 79 | Polyamide or Braided white nylon rope-12 mm |
| 80 | Polyamide or Braided white nylon rope-14 mm |
| 81 | Polyamide or Braided white nylon rope-20 mm |
| 82 | Air-conditioner |
| 83 | Split AC(capacity-2T) Five Star rating |
| 84 | Ventillation system for 220kV & 33kV GIS Hall |
| 85 | LT Switchboard |
| 86 | 415V main switchboard |
| 87 | 415V ACDB |
| 88 | MLDB |
| 89 | ELDB |
| 90 | NLP |
| 91 | ELP |
| 92 | 220V DCDB |
| 93 | 50V DCDB |
| 94 | Batteries |
| 95 | 220V500AH |
| 96 | 48V 300AH |
| 97 | Battery charger system |
| 98 | 220V, 100Amps Float Cum Boost Charger |
| 99 | 48V, 60Amps Float Cum Boost Charger |
| 100 | 250kVA, 440V DG set alongwith control panel |
| 101 | Fire Prevention & Extinguishing System |
| 102 | Fire Alarm System for 220 kV & 33 kV GIS hall, Control Room Building |
| 103 | CO2 Type Fire Extinguisher 9 kgs |
| 104 | CO2 Type Fire Extinguisher 4.5 kgs |
| 105 | Mechanical Foam Type Fire Extinguisher 9 Ltrs |
| 106 | Bucket Stand (including 4 Buckets with sand fill) |
| 107 | Illumination sytem |
| 108 | 33kV GIS Room / Control Room / Store Room / Offices llumination (LED Type Lights) |
| 109 | Switchyard lighting (LED Type Lights) with mounting accessories |
| 110 | Solar light system for street light (LED Type Lights) with Pole and other mounting accessories |
| 111 | LED Lights for 220kV GIS, High Bay type 170 Watts |
| 112 | 1.1kV Aromoured Power Cables (AL) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc. |
| 113 | Power cables Aluminium (XLPE) |
| 114 | 3.5cx300 Sq.mm |
| 115 | Power cable Aluminium (PVC) |
| 116 | 3.5cx70Sq.mm |
| 117 | 3.5cx35Sq.mm |
| 118 | 4cx16 Sq.mm |
| 119 | 4cx6 Sq.mm |
| 120 | Control cable Copper (PVC) |
| 121 | 2Cx2.5Sq.mm |
| 122 | 4Cx2.5Sq.mm |
| 123 | 6Cx2.5Sq.mm |
| 124 | 10Cx2.5Sq.mm |
| 125 | 220 kV and 33 kVPower Cable and accessories |
| 126 | 220kV XLPECopper Power cables for connecting Air/Cableto 220KV GIS of size 1 X 1200 sq.mm. |
| 127 | 220KV Indoor termination suitable for above cable (3 Nos.) |
| 128 | 220 KV Outdoor Cable Bushing for above cable (3 Nos.) |
| 129 | 33kV XLPE Copper Power Cables for connecting Transformer to 33KV GIS of size 1 X 630 sq.mm. |
| 130 | 33KV Indoor termination suitable for above cable (3 Nos.) |
| 131 | 33KV Outdoor termination suitable for above cable (3 Nos.) |
| 132 | 33kV XLPE Copper Power Cablefor Auxiliary Transformer of size 1 X 185 sq.mm. |
| 133 | 33kV Indoor Termination (3Nos.) |
| 134 | 33kV Outdoor Termination (3Nos.) |
| 135 | Grounding/Earthing system |
| 136 | 40mm MS rod for earthmat and3 metre Electrodes |
| 137 | GS/MS Flats |
| 138 | GS shield Wire |
| 139 | Steel structure |
| 140 | Lattice structure |
| 141 | Pipe structure |
| 142 | EOT Crane |
| 143 | EOT Crane for 220KV GIS Room |
| 144 | Moveable ladder of suitable capacity for 220 KV & 33 KV GIS Room |
| 145 | Mandatory spares |
| 146 | Mandatory spares as per the list indicated in section-Project, Technical Specification. |