Tender For Construction Of Foot Over Bridge At Km 9.162 In Inner Ring Road Near Kendriya Vidyalaya School
Tender Value
10.13 Crore
Estimated cost
Bid Submission
02 Jan 2023
0 days left
EMD
5.18 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
thirumangalam → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Foot Over Bridge At Km 9.162 In Inner Ring Road Near Kendriya Vidyalaya School
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-Dec-2022 | Drawings Schedule B | Technical Bid | 02-Jan-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of existing Plain Cement Concrete in footpath and median crash barrier including the cost of T&P and scaffolding where ever necessary, salvaging the dismantling materials, stacking as per the Engineer\"s guidance, disposal of unserviceble materials with all lifts, leads and transportation, complete as per relevant MORT&H Specification cl:202. |
| 2 | Dismantling of existing RCC structues like median crash barrier and footpath cum drain including disposal of unserviceable material and stacking the serviceable material with all lift and lead as per relevant MORT&H Specifications Cl:202. |
| 3 | Earthwork in excavation of Foundation of structures as per drawing and technical specification including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling the excavated soil in the Centre Median for shrub plantation and conveyance of excess earth for proper disposal upto a lead of 10 kmincluding supervision charges, watch and ward, , Traffic management complete as per relevant MORT&H Specifications cl: 301&304. |
| 4 | Plain Cement Concrete M15 Grade using 20mm ISS size hard broken granite metal including cost and conveyance of all materials to site,cost and labour charges for form work and centering, labour charges for compacting, curing and all incidental charges etc., complete for LEVELLING COURSE BELOW FOOTINGS as per relevant MORT&H Specifications cl: 1000&2100. |
| 5 | Vibrated Reinforced Cement Concrete of grade M25 (Design mix) using 20mm ISS graded metal including cost and conveyance of all materials to site and cost cement at site excluding cost and fabrication of steel including cost of formwork, soft water, labour charges for mixing, transporting, laying and curing concrete, workingatdepthsToolsand Plants and incidental charges such as bailing out water, maintaining of protective bunds, cofferdams, shoring, strutting etc., complete for DRAIN BASE SLAB, WALL, COVER SLAB (Using OPC) as per MORT&H specifications 1000,1500,1600,1700&2300. |
| 6 | Vibrated Reinforced Cement Concrete of grade M35 (Design Mix) using 20mm ISS size hard broken granite metalincluding cost and conveyance of all materials to site, cost and labour charges for formwork, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing, working at depths, Tools and Plants and incidental charges such as bailing out water, shoring, strutting etc., complete for FOOTINGS as per relevent MORT&H specification Cl:1000,1500,1600 &1700. |
| 7 | Vibrated Reinforced Cement Concrete of grade M35 (Design Mix) using 20mm ISS size hard broken granite metalincluding cost and conveyance of all materials to site, cost and labour charges for formwork, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing, working at depths, Tools and Plants and incidental charges such as bailing out water, shoring, strutting etc., complete for PEDESTALS AND PLINTH BEAM as per MORT&H specifications Cl:1000,1500,1600 & 1700. |
| 8 | Supply and fabrication of HYSD STEEL of grade Fe 500 D/CRS/HCRM/Anti corrossive treatment including cost of steel, cost of fabrication, labour charges for cleaning the rods, straightening, cutting, bending, tying grills, placing the reinforcement in position as specified in the drawing including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc., complete for FOOTINGS, PEDESTALS and DRAIN CUM FOOTPATH as per relevant MORT&H Specifications Cl:1600. |
| 9 | Vibrated Reinforced Cement Concrete of grade M30 (Design Mix) using 20mm ISS size hard broken granite metalincluding cost and conveyance of all materials to site, cost and labour charges for formwork, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing, working at depths, Tools and Plants and incidental charges such as bailing out water, shoring, strutting etc., complete forFLOOR SLAB CUM BEAM AND LINTEL OF MAINTENANCE ROOM as per relevent Specifications of MORT&H Cl: 1000,1500,1600,1700&2300. |
| 10 | Supply and fabrication of HYSD STEEL of grade Fe 500 D/CRS/HCRM/Anti corrossive treatment including cost of steel, cost of fabrication, labour charges for cleaning the rods, straightening, cutting, bending, tying grills,placing the reinforcement in position as specified in the drawing including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc., complete for for MAINTENANCE ROOM upto ground level as per relevant MORT&H Specifications Cl:1600. |
| 11 | Filling with quarry fines over footingfor entire depth not exceeding 250mm thick layers as directed by the department officers including compacting each layer to the required density in accordance with IS 2720 Part VII at 95% Proctor Density for top 0.50 M depth as sub grade level and shoulders keeping the moisture content of earth at the time of compaction within the range of 1% above and 2% below the OMC determined and Plasticity Index value of not more than 20 and liquid limit not greater than 40 in accordance with IS 2720 using required capacity earth rammers to achieve required density in each layer including watering with all leads for water and finishing the surface to the line and grades, sections as directed as per relevant MORT&H Specifications Cl:305. |
| 12 | Vibrated Cement concrete of M20 Grade using 20mm ISS size hard broken granite metal including cost and conveyance of all materials to site,cost andlabour charges for form work and centering, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing and all incidental charges etc., complete for BED PROTECTIVE CONCRETE over the filled portion in foundation at ground level to a thichness of 200mm as per relevant MORT&H Specifications Cl:1000&2100. |
| 13 | Supplying and fixing of M.S. Foundation bolts & nuts of approved quality for specified diameterand length for connection of structural members including plain/spring washers, drilling to the base, use of chemicals for base fixing as per detailed drawing and technical specifications etc., complete and as directed by the Engineer-in-charge as per relevant MoRTH Specifications Cl:1900. |
| 14 | Vibrated Reinforced Cement Concrete of grade M40 (Design Mix) using 20mm ISS size hard broken granite metalincluding cost and conveyance of all materials to site, cost and labour charges for formwork, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing, working at depths, Tools and Plants and incidental charges such as bailing out water, shoring, strutting etc., complete for MEDIAN CRASH BARRIER as per MORT&H specifications Cl:1000,1500,1600 & 1700. |
| 15 | Supply and fabrication of HYSD STEEL of grade Fe 500 D/CRS/HCRM/Anti corrossive treatment including cost of steel, cost of fabrication, labour charges for cleaning the rods, straightening, cutting, bending, tying grills,placing the reinforcement in position as specified in the drawing including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc., complete for MEDIAN CRASH BARRIER as per relevant MORT&H Specifications Cl:1600. |
| 16 | Plantation of Shrubs in central median of roadincluding planting with manure, including initial Watering, tools and all incidental charges,as directed by the Engineer-in-Charge. |
| 17 | Providing and fixing Stainless steel Pedestrain Guard rail for footpath made out of SS 304 grade 50 mm dia stainless steel tube of 1.5 mm thick at required locations to a height of 1.2 m from finished floor level welded to two 50 mm dia stainless steel tube of 1.5 mm thick with base plate 15 x 15 cm and with6 nos. of 15 mm dia vertical horizontal stainless steel tube of 1.5mm thick with arch type design in between, as per drawings and as directed by the Engineer in Charge, includinggrouting with concrete fixing and necessary supporting arrangements of handrail vertical and in floor, welding the base cup of the post into slab reinforcement polishing, buffing and pretesting the handrail surface, etc. |
| 18 | Vibrated Reinforced Cement Concrete of grade M35 (Design Mix) using 20mm ISS size hard broken granite metalincluding cost and conveyance of all materials to site, cost and labour charges for formwork, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing, working at depths, Tools and Plants and incidental charges such as bailing out water, shoring, strutting etc., complete for DECK SLAB with kerb over decking sheet as per MORT&H specifications Cl:1000,1500,1600, 1700 and 2300. |
| 19 | Supply and fabrication of HYSD STEEL of grade Fe 500 D/CRS/HCRM/Anti corrossive treatment including cost of steel, cost of fabrication, labour charges for cleaning the rods, straightening, cutting, bending, tying grills, hoisting and placing the reinforcement in position as specified in the drawing including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc., complete for DECK SLAB with kerbas per relevant MORT&H Specifications Cl:1600. |
| 20 | Supplying, fabricating and erection ofStructural Steel works as per detailled drawing and technical specifications, comprising UB sections, IS Channel sections, IS angles, plates, tees, flats, pipe, tube sections and other structural steel sections including cutting, bending to shape, welding and traffic management, lighting, safety arrangements, tools and plants etc., complete for SUPERSTRUCTURE & SUB STRUCTURE OF FOOT OVER BRIDGE AND SKYWALK as per relevant MoRTH Specifications Cl:1900. The Contractor shall submit the fabrication drawings for the work invloved based on the construction drawings ( issued by the department) for approval by the Engineer- in -charge before commencing the fabrication works. Any changes required in the fabrication drawings shall be carried out at no extra cost. Fabrication works shall be carried out in a professional workmanship manner and as provided in Section 17 of IS 800-2007. Welding shall be carried out by qualified welders and electrodes for welding, erection/hoisting shall commence only after the approval of pre fabricated parts by the Engineer-in-charge. The procedure, selection, test and inspection shall conform to the provisions in IS 816, IS 818, IS 822 & IS 823. |
| 21 | Supply and fixing of Pre-fabricated Structural Steel DECKING SHEET having minimum 345 Mpa yield strength, colour coated Galvanised Steel with Z275 (min 275 g/m2 Zinc coating as per IS:277 or equivalent Standard. The structural decking panel shall have 915 mm effective width (Overall Width of 931mm), nominal crest height 50 mm deep ribs at230 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action and shall have the thickness of 1.25 mm BMT for fixing using shear studs of required length as per Concrete thickness at site (165mm Avg) with self drilled screws and EPDM wahers. |
| 22 | Supply and fixing of Pre-fabricated Structural Steel, coated galvalume ROOFING SHEET of 0.5mm thickness with SMP coating with colour bond XRW coating, having minimum of 550 Mpa yield strength, Coating 150 GSM as per ASTM 792 or equivalent standard. The structural roofing Pannel shall have 1020 mm effectivewidth, nominal 30 mm crest height at nominal 250 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action including Flashing for joints, and all incidendental charges |
| 23 | Providing and applying one coat of Zinc oxide primer and two coats of Anti Corrosive paint ofColour as directed by engineer in charge on structural steel , etc all complete as per technical specification in accordance with IRC 24-2010 and other relevant MORT&H Specifications Cl:1906. |
| 24 | Brick masonry in Cement Mortar 1:6, 230 mm thick using best quality II class ground moulded chamber burnt bricks of size 9\" x 4 3/8\" x 2 3/4\" for Maintenance Room including cost towards curing, etc., complete complying with standard specification. |
| 25 | Plastering with Cement Mortar 1:4 (one cement & four sand), 12 mm thick on brick work for internal sides of walls in all floors as per Technical Specifications. |
| 26 | Plastering with Cement Mortar 1:4 (one cement & four sand), 20 mm thick on brick work for external sides of walls in all floors as per Technical Specifications. |
| 27 | Providing and applying two coats of acrylic paint to the external and internal surfaces of plastered finish, using exterior quality acrylic weather shield paint of approved shade and make including preparing the base surface, attending to broken edges, corners etc. as per technical specifications. |
| 28 | Chequerred precast Cement based hydraulically pressed anti-skid (Pattern Design) tiles, 20mm thick laid in CM 1:3 (one cement & three sand) and pointed with white cement mixed with colouring pigment @ 0.40 Kg/Sqm and cost towards curing,etc., Complete for Main walkway, Staircase, Kerbas per technical specifications. |
| 29 | Providing and fixing of Machine Cut granite stone slab for flooring of size 0.60m x 0.60m x 50mm granite slab for platform flooring and pointing with cement mortar 1:3 including cost and conveyance of approved quality of granite stone as specified by the departmental officers including cost and conveyance of all materials to work site including cost of cement which has to be procured by the contractor including labour charges for fixing the granite stone slab in correct position to the required line and gradient over foot path as directed by the departmental officers and all other incidental charges etc. complete as per standard specification. |
| 30 | Flooring with first quality design Coloured Ceramic tiles of 305 x 305 x 6 mm size, laid over 20mm thick Cement Mortar 1:3 (one cement & three sand) base mortar over walls including cutting the tiles to required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment @ 0.30 Kg/sqm etc., complete as per technical specifications. |
| 31 | Providing, fabricating & fixing in position STAINLESS STEEL HANDRAIL consisting of 75mm (outer dia) at top and four intermediate pipes 40 mm dia including profile cutting, fixing in position, 2 nos of vertical balustrades made of 75 x 12 mm thick Stainless Steel flat metal plates, placed at 1500 mm c/c or at required spacing , necessory anchor fasteners /approved fixing arrangements to the wall, welding using special electrodes for stainless steel building etc., complete as per detailed drawing and as directed by the Engineer - in-Charge. The stainless steel shall be of non-magnetic type with minimum wall thickness of 1.5 mm & confirming to grade 304 Jindal. |
| 32 | Supply and erection of public service HEAVY DUTY ESCALATORS outdoor type (GS8000-NX) with the Techniccal Specification as Step Width:1000mm, Rise:6500mm, Inclination Angle:30 degree, Speed: 24m/min, Power supply:220V/400V, 50Hz. Material Specification such as Handrails made of Polyuerthane(Blood red colour), Handrail frame of Hairline(finished stainless steel), Deck cover of Hairline(finished stainless steel), Interior panel-Balustrade of TYPE-P (Stainless steel), Skirt Guard of Hairline (finished stainless steel), Step tread of Stainless steel with synthetic Resin Demarcation(Yellow), Floor plate Comb of Synthetic Resin (Yellow), Landing plate of Aluminium including allnecessary safety devices & accessories, comb light shall be mounted on the skirp guard with 1m center to center arrangement and complete in all respectsand as directed by the Engineer-in-Charge. |
| 33 | Supply and erection of public service 13 persons (884 kg) STAINLESS STEEL LIFT / ELEVATORSand complete in all respects as per company standards and as directed by the Engineer-in-Charge. |
| 34 | Supplying, fabricating and fixing in position of aluminium anodized DOOR partly half glazed at top and half panelled at bottom with frame made out of box section 101.6 x 44.5 x 3.18 mm thick @ 2.319 kg/m door shutters made out of box section 47.1 x 44.45 x 2.50 mm @ 1.202 kg/m for vertical slide and top, lock rail sections of size 50 x 44.5 x 2.5 mm @ 1.292 kg/m and bottom 100.4 x 44.45 x 2.5mm @ 1.974 kg/m using clips of size 17.15 x 17.27 x 1.50 mm @ 0.176 kg/m with neccesary metal screws, rubber beadings, strike plate type handle of size 100 x 30 x 1.60 mm @ 0.988 kg/m on both sides, tower bolts, lock pivot arrangements and top half portion with 5.50 mm thick plain glass and bottom half portion with one side pre-laminated board (MDF) 12mm thick for panelled portions with one number of hydraullic door closure of approved quality using alluminium extruded section body tubular type universal with double speed adjustment with ISI Monogram including cost of furniture fitting such as pivot, hinges, tower bolt, lock, door stopper and all materials , labour power consumtion required for fabrication,drilling required for fabrication,drilling holes in RCC columns, floor slabs, Masonry walls wherever neccessary with power drills to the required extent and make the same to original condition after fixing and as directed. All the alluminium sections are to be anodized with mat finish under electrical controlled condition in accordance with IS:1868 - 1962 for an average anodic film thickness of 15 microns etc., complete. The rate shall be inclusive of materials, labour for fixing, transporting, loading ,unloading etc., |
| 35 | Supplying, fabricating and fixing in position aluminium natural colour matt finish WINDOW /VENTILATOR with sliding and gutter arrangements so as to drain the water entering and made with extruded aluminium section of the sizes given below with necessary accessories such as rubber beadings, best quality runner, lock, handle supplying and fixing 4 mm thick plain glass including cost of all materials, labour, power consumption required for fabrication, drilling holes in RCC Column/floor slab/masonry wall wherever necessary with power drills to the required extent and made same to original condition after fixing etc.,complete. The aluminium sections are to be anodized with matt finish under electrically controlled condition in accordance with ISI 1868-1962 for an average anodic film thickness of no less than 15 microns. All aluminium sections and furniture fittings shall be got approved by the Engineer-in-Charge before use on works. |
| 36 | Supplying and erection of push and pull type ROLLING SHUTTERS (Gear Operated type) with ISI make of approved size and section using 18 G.I. sheet. The shutter shall be painted with one coat of red oxide primer andthe rate is inclusive of hood covers, transportation charges,etc., |
| 37 | Supplying and fixing GI DRAINAGE SPOUTS 100mm dia as per GOI drawing SD/205 with grating arrangements at top as shown in the drawing and 100mm dia drainage spout projecting atleast 300mm beyond the bottom of deck slab as shown in the drawing, including cost andonveyance of Galvanised iron pipes and flats and fixing them in position,etc., complete as per cl 2705 of MORT&H specification. (V Revision) |
| 38 | Supply and fixing of best quality ISI PVC DOWN TAKE PIPES (A Class) 4 kg/cum of 110mm dia including necessary specials such as elbow, tee etc. including cutting, threading, jointing for providing bends at ends and tees it the middle, including cost of fixing clamps including cost and conveyance of pipe specials labour charges for fixing in position vertically in trestle portion and all other incidental charges etc., as per MORT&H specifications 2706. |
| 39 | Supplying and installing of CCTV CAMERAS of 1 set comprising as listed below, including installation charges and other componentswith all other neccesory accessories and complete in all respects.a) Supply, Installation, Testing & CommissioiningSupports 16CH IPC & 4CH local alarm input & 1CH alarm output, USB 2.0x2, RS 485x1, HDMI Output: 4K x 2K & VGA output, Local & NetworkBackup, ARTIFICIAL INTELLIGENCE ALLEATURE NVR- 1 No b) Supply, Installation, Testing & Commissioining of6TB Survillience Hard disc - 2 Nosc) Supply, Installation, Testing & Commissioining of I+A26C+G12R, True D/N, 2D/ 3D DNR,,WDR ,STARLIGHT ,FACE DETECTION , LINECROSSING ,PEOPLE COUNTING, ECT / PoE,IP69-12 Nosd) Supply, Installation, Testing & Commissioining of 08 Channel POE Switch - 2 Nose) Supply, Installation, Testing & Commissioining of 16 Channel Gigabite Switch 10 / 100 / 1000.-1 Nof) Supply of 12U Rack at each Server Room: 12U Rack with Power Manager, Cooling Fan Partition Tray. -1 Nog) Supply of 1 KVA UPS -1 Noh) Supply of Weather Proof Junction Box for Camera -12 Nosi) Supply of 42\" LED Monitor with Wall mount stand (Brand LG/ TCL Commercial HDMI Monitor for continuous Display.) - 1 No j) Supply of HDMI & VGA Cable- 1 No k)Supply of Cat 6 Armored Cable - 1700 Rm(Billing as per Actual) l)Cable Laying Charges-1700 Rm |
| 40 | Supplying and installing PUBLIC ADDRESS SYSTEM of 1set comprising as listed below, including installation charges and other components with all other neccesory accessories and complete in all respects.Table Top Mike - 1 NoAmplifier- 1 No30 watts Horn speaker- 8 Nos10 Zone Console - 1 No 2core armourd (with Laying) - 1350m30 watts Wall Mount Speaker in monitoring room - 1No |
| 41 | Supply of 125 KVA DIESEL GENERATOR as per CPCB-2 norms at 1500 RPM under NTP conditions complete with standard accessories rated at 125 KVA 0.8PF (lag), 415V, 3phase, 4wire, mounted on a common iron based frame, suitably rated battery with leads, silencer, fuel tank, manual Control Panel and set of AVM pads, composite type enclosure and AMF panel suitable for 1 EB connection shall be kept outside and inside enclosure (in lieu of Manual Control Panel) with all other neccesory accessories and complete in all respect as per relevant technical specification and as directed by the Engineer-in-Charge. |
| 42 | Two coats of painting over primed surface with synthetic exterior emulsion paint white and black alternatively in strips on new concrete surfaces including cost of materals, labour,working at heights, cost of scaffolding etc. complete for Crash Barrier as per relevant technical specification and as directed by the Engineer-in-Charge. |
| 43 | Supply and fixing of Heavy duty FRC man holes Cover with Frame of size 600 mm dia along road both sides at 5 m C/Cas per SP-IRC:50-1999 as directedby the departmental officersalong the drains as per standard specifications. |
| 44 | Providing and fixing of M.S Gratings for drain @ intervel of 5 m of 600 x 200 mm size with M.S flats of 25x10 mm for outer frames, 25x6 mm for inner braces and PVC pipe 150 mm dia fixed with mild steel grating, including cost and conveyance of pipes and gratings and fixing them in position as directedby the departmental officers and as per relevantMORT&Hspecification Clause 1900. |
| 45 | Sub Estimate For Electrical Works |
| 46 | a) Electrical estimate for Main structure |
| 47 | EB METERING PANELFabrication,Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, wall mounted panel board made out of 16 SWG thick CRCA sheet , duly rust inhibited,degreasing,zinc phosphating and painted with epoxy paints of approved colour and quality over a coat of zinc-cromatic primer and properly powder coated, complete with hinged and earthed front doors , name plate,danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel, all connections and inter-connections including mounting the following .Incomings:315 A Rewireable fuse with base- 3Nos.315 A Neutral link - 1No. 250A TPN SDFUProvision for mounting of 3 phase energy meter |
| 48 | i)Supply |
| 49 | ii)Labour |
| 50 | Sub PanelFabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel boardmade out of 16 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthedfrontdoors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel. All opening parts of the panel shall be sealable. (the panel shall have CPRI approval certificate)Incomer:250 A TPN SDFU - 1 No250 A 415V 25kAbest conductivity AluminiumTPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Outgoings:200A TPN SDFU - 2 Nos |
| 51 | i)Supply |
| 52 | ii)Labour |
| 53 | Main PanelFabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel boardmade out of 16 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthedfrontdoors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel. All opening parts of the panel shall be sealable. (the panel shall have CPRI approval certificate)Incomer:200 A TPN MCCB- 1 No200 A 415V 25kAbest conductivity AluminiumTPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Outgoings:100 ATPN 25kA MCCB - 4 Nos + 63 ATPN 25kA MCCB - 4 Nos |
| 54 | i)Supply |
| 55 | ii)Labour |
| 56 | CAPACITOR CONTROL PANEL ( 40 KVAR ) Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel boardmade out of 16 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthedfrontdoors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel. All opening parts of the panel shall be sealable. (the panel shall have CPRI approval certificate)Incoming FeedersOne (1 ) 200A, TPN, SDFOne (1) - set indicating lamps as required to indicate ON, OFF,& TRIP circuit healthy and also phase indicating lamps. 200/ 5A, 5VA/Cl 1.0, 5VA for PF Control . Short time rating of CTs shall be 25kA for one (1) second.Suitable for 3phase, 4wire, 50HZ, 415V, 125A, 25kA for 1s, Aluminum Busbars & SMC Busbar. supports to be provided in every 250mm interval.Total Number of Outgoings Feeders - 4 Nos6stage automatic power factor control relay as required. ( No. of banks to be made suitable by paralleling any two banks ) With Auto Manual Change Over Switches.One Number (1) Outgoing feeders each consisting of following switch gears & components.100 A TPN, MCB The coil voltage shall be 240V, single phase, 50Hz, AC Suitable rating capacitor duty Contactorincluding with heavyduty, MIXED DI-ELECTRIC (MDXL) 25 kVAr TP capacitor with internal wiring, fuses etc, complete as required with ON / OFF Push button etc..Three Number (3) Outgoing feeders each consisting of following switch gears & components.32A, TPN, MCB The coil voltage shall be 240V, single phase, 50Hz, AC Suitable rating capacitor duty Contactorincluding with heavyduty, MIXED DI-ELECTRIC (MDXL) 5kVAr TP capacitor with internal wiring, fuses etc, complete as required with ON / OFF Push button etc.. |
| 57 | i)Supply |
| 58 | ii)Labour |
| 59 | DG CHANGE OVER PANELINCOMERIncoming feeders each consisting the Follwing Switching gears and components :One (1) 200 A, TPN, 25kA, (Icu=Ics) Fixed type, Single break, MCCB .The MCCB shall be with trip free feature with terminal shrouds with inbuilt Thermal - Magnetic based(adjustable) overload & short circuit release complete with FD kit (Rotary operated handle mechanisim).(Incoming From EB Source)One (1) 200 A, TPN, 25kA, (Icu=Ics) Fixed type, Single break, MCCB .The MCCB shall be with trip free feature with terminal shrouds with inbuilt Thermal - Magnetic based(adjustable) overload & short circuit release complete with FD kit (Rotary operated handle mechanisim).(Incoming From DG Source)One ( 1 ) - Set ofVoltmeter with 4P MCBOne ( 1 )set ( 1 No ) -RYB phase indicating lamps with fuse.One ( 1 )set ( 1 No ) -Trip indicating lamps with fuse.One ( 1 ) Outgoing having with following SwitchGear and ComponentsOne ( 1 ) Set of Two ( 2 ) Nos.200 A , 4P Power contactors AC - 3.0 Duty application , rating with in built surge suppressor change over arrangement complete with One (1) No. Line voltage Monitor with SPP + UV + OV features of GIC make SM 500 model with 4Nos. SP 2A MCBs & indication lamps including with auxilary contactors,with surge suepressor , 2way auto manual selector switch, 2 sets of ON/OFF push buttons,control circuit MCBs, 1 No. 200 A 4P Manual change over switch & internal control wiring etc. for safe & smooth operation of automatic change over arrangement. Please refer typical control circuit drawing enclosed. |
| 60 | i)Supply |
| 61 | ii)Labour |
| 62 | Earthing |
| 63 | Supply and installation of 600mmx600mmx3.15mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, SFRC cover withframe - 20 tone capacity heavy duty,GI class \"B\" watering pipe of 50 mm dia withfunnel having20G GI wire mesh etc, CI manhole cover with frame shall be painted with bitumastic paint, identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 2.5 meter depth and back filling. ( value of earth resistance should be less than 1 ohm ). (For Generator Earthing) |
| 64 | i)Supply |
| 65 | ii)Labour |
| 66 | Supply and installation of 50mm dia,B class GI pipe electrode earth station conforming to IS 3043-1987/NEC/IEE complete with brick mansonry chamber, CI cover, CI frame ,GI watering funnel with 20G GI wire mesh etc, The CI cover frame/ chamber shall beof 450mm x 450mm x 300mm size. CI manhole cover with frame shall be painted with bitumastic paint,identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 3.5 mtr depth and back filling. (Escalator- 4 Nos & Panel- 1 No) |
| 67 | i)Supply |
| 68 | ii)Labour |
| 69 | Supply and clamping GI strips of the following sizes on surface of wall/trench/cable tray etc using using bolts, nuts, washer, welding etc as required. 25 x 3 mm GI strip (For Generator) |
| 70 | i)Supply |
| 71 | ii)Labour |
| 72 | Supply, laying/fixing of earthing conductor of CU flat /wires jointing as per IS; 3043/87 in trench walls pulling through pipes etc as required)a) Copper wire No.8 SWG (For Escalators) |
| 73 | i) Supply |
| 74 | ii)Labour |
| 75 | b) Copper wire No.6 SWG (For Panels) |
| 76 | i) Supply |
| 77 | ii)Labour |
| 78 | CABLE LAYING & END TERMINATION Supplying and laying the following XLPE insulated PVC sheathed armoured 1.1KV grade Aluminium conductor cable conforming IS: 1554 (Part-I) in cable trenches or on concrete wall or through pipes as per specifications, including providing ofcable route markers in every 50M and at all strategic turning/diversion points etc. Necessary clamping should be provided while burying cables in prepared trenches etc. as instructed by the Site Engineer |
| 79 | a) 3.5 x 120 Sq mm. Al Cable (Incoming Cables) |
| 80 | i)Supply |
| 81 | ii)Labour |
| 82 | b) 3.5 x 50 Sq mm. Al Cable (Incoming Cablefor Escalators) |
| 83 | i)Supply |
| 84 | ii)Labour |
| 85 | c) 3 x 4 Sq mm. Al Cable (Light Loads) |
| 86 | i)Supply |
| 87 | ii)Labour |
| 88 | d) 3 x 6 Sq mm. Al Cable (pathway Surface Mounted lights) |
| 89 | i)Supply |
| 90 | ii)Labour |
| 91 | e) 4 x 25 Sq mm. Al Cable (V.D.B incoming cable) |
| 92 | i)Supply |
| 93 | ii)Labour |
| 94 | f) Cable route marker (Refer 4.1) |
| 95 | i)Supply& Labour |
| 96 | Cable End Termination supplying and terminating siemens type / tropdoor compression gland, Aluminium lugs, earth clamps for XLPE insulated and PVC sheathed armoured conductor cable 1.1kv grade and making end terminations suitable for 2/3/3.5/4 core cables of the following sizes as required |
| 97 | a) 3.5 x 120 Sq mm. Al cable (incoming cables) |
| 98 | i)Supply |
| 99 | ii)Labour |
| 100 | b)3.5 x 50Sq.mm. Al cable (incoming cable for Escalators) |
| 101 | i)Supply |
| 102 | ii)Labour |
| 103 | c) 3 x 4 Sq mm. Al Cable (Light Loads) |
| 104 | i)Supply |
| 105 | ii)Labour |
| 106 | d) 4 x 6 Sq.mm. Al cable (Escalator lighting loads) |
| 107 | i)Supply |
| 108 | ii)Labour |
| 109 | e) 4 x 25 Sq.mm. Al cable (V.D.B incoming cable) |
| 110 | i)Supply |
| 111 | ii)Labour |
| 112 | FLEXY DISTRIBUTION BOARD |
| 113 | Flexy DBSupplying and fixing of the following way factory made single/three pole and neutral, sheet steel, RCCB Flexy distribution board enclosure, double shuttered on surface /recess complete with tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, cable end box, including painting, earthing etc as required. (IP 42) in recess/in surface including cutting holes on the wall making good the damage colour cleaning etc. as required.The rate should include cost ofmaterials required for DB dressing like cable mount, using proper lugs for incoming and outgoing cable , cable ties, black tape, black buttons, end ferrules, stickers etc., complete. |
| 114 | a) Three phase 4 tier- IP 42 protection metal door Flexy DB (4row of 13 modules) |
| 115 | i)Supply |
| 116 | ii)Labour |
| 117 | Incomings of Flexy D.B: |
| 118 | Residual Current Circuit Breaker |
| 119 | Supplying & fixing the following rating miniature circuit breaker of following poles in existing Flexy DB complete with connections, testing and commissioning etc as required. |
| 120 | a) 63A 30mA FP RCCB |
| 121 | i)Supply |
| 122 | ii)Labour |
| 123 | Outgoings from Flexy D.B: |
| 124 | Power contactors |
| 125 | Supplying & fixing the following rating Power contactors of following poles in existing Flexy DB complete with connections, testing and commissioning etc as required. |
| 126 | a) TP 40A power contactor |
| 127 | i)Supply |
| 128 | ii)Labour |
| 129 | Digital timer switch |
| 130 | Supply, testing, installation and commissioning of digital timer switch housed in a suitable factory made M.S box with moulded front plate including earthing the box,3 plate ceiling rose etc. complete with necessary accessories like screws, nuts, internal wiring etc |
| 131 | Multi functional digital (Alpharex D22) |
| 132 | Additional Accessories (Data key for digital switches and USB port for digital time switches) |
| 133 | i)Supply |
| 134 | ii)Labour |
| 135 | Miniature Circuit Breaker |
| 136 | Supplying & fixing the following rating miniature circuit breaker of following poles in existing Flexy DB complete with connections, testing and commissioning etc as required. |
| 137 | a)(6-32)A SPMCB (Light loads) |
| 138 | i)Supply |
| 139 | ii)Labour |
| 140 | CIRCUIT BREAKERS |
| 141 | Miniature Circuit Breaker Isolator (Escalator incomer) |
| 142 | Supplying & fixing the following rating miniature circuit breaker of following poles in existing VDB complete with connections, testing and commissioning etc as required. |
| 143 | a)100AFP MCB isolator |
| 144 | i)Supply |
| 145 | ii)Labour |
| 146 | Miniature Circuit Breaker (Pathway lights) |
| 147 | Supplying & fixing the following rating miniature circuit breaker of following poles in existing VDB complete with connections, testing and commissioning etc as required. |
| 148 | a)(6-32)A MCB |
| 149 | i)Supply |
| 150 | ii)Labour |
| 151 | Miniature Circuit Breaker with metallic enclosure |
| 152 | Supplying & fixing the following rating miniature circuit breaker of following poles in existing VDB complete with connections, testing and commissioning etc as required. (Sky walk, ramp & foot over bridge) |
| 153 | a)(6-32)A MCB |
| 154 | i)Supply |
| 155 | ii)Labour |
| 156 | WIRING SYSTEM |
| 157 | Wiring Light / exhaust fan point |
| 158 | Supplying all materials and wiring for light points/exhaust fan using 3 runs of1.5mm² 650V grade PVC insulated copper conductor single core FRLS wiresrun continously as per IS through ISIgrade medium gauge rigid PVC conduits concealed in wall / slab etc, complete with necessary accessories, including supplying and fixing 6A modular type switch housed in a suitable factory made M.S box with moulded front plate including earthing the box,3 plate ceiling rose etc. complete as required.( The earth wire shall be green colour) |
| 159 | i)Supply |
| 160 | ii)Labour |
| 161 | 6A Plug points - combined position |
| 162 | Supplying all materials and wiring for 6A plug points in combined positions using 1.5 sq.mm PVC insulated copper conductor single core FRLS wirerun continously as per IS through ISIgrade medium gauge rigid PVC conduits concealed in wall / slab etc, complete with necessary accessories and fixing 6A modulartype 3 pin shuttered plug socket (2 in 1) controlled by 6A switch with moulded front plate, housed in a suitable factory built MS box.Giving connections, earthing etc complete as required. This circuit shall be looped to the lighting circuit. |
| 163 | i)Supply |
| 164 | ii)Labour |
| 165 | 16/ 6A Power plug points |
| 166 | Supply and providing 16 / 6A combined modular type power plug socket (shuttered) controlled with 16A modular type switch, mounted on a suitable factory built MS box with earthing facility, giving interconnections etc as required. |
| 167 | i)Supply |
| 168 | ii)Labour |
| 169 | Telephone System |
| 170 | A) Supply and Providing of (telephone junction box) Epoxy coated MS Enclousre with KRONE Make SS Backmount Frame & Disconnection Module mounted on the wall including all accessories a)10 Pair Ms Enclosure With Bmf & DCM |
| 171 | i)Supply |
| 172 | ii)Labour |
| 173 | B) Supply and laying offollowing pair 0.5 mm² telephonecable through existing conduit. a) 2 pair cables |
| 174 | i)Supply |
| 175 | ii)Labour |
| 176 | Circuit mains: |
| 177 | 3Runs 1.5 sq.mm. Cu wireSupply and wiring of 3 runs of 1.5 sqmm PVC insulated fine stranded FRLS cu wire drawn through suitable size ISI grade mediumPVC conduit including all accessories as required.( conduit separate item )(For circuit mains etc)(The earth wire shall be of green colour) |
| 178 | i)Supply |
| 179 | ii)Labour |
| 180 | 3Runs 2.5 sq.mm. Cu wireSupply and wiring 3 runs of 2.5sq.mm PVC insulated fine stranded FRLS copper wire drawn through 25mm ISI grade rigid/flexible PVC conduits including all accessories as required (For 15A/Gyeser points)(The earth wire shall be of green colour) |
| 181 | i)Supply |
| 182 | ii)Labour |
| 183 | Conduits: |
| 184 | 20mm PVC ConduitSupply and providing of 20 mm electrical grade ISI heavy duty PVC conduit through wall, ceiling etc. including the supply of all accessorises required. |
| 185 | i)Supply |
| 186 | ii)Labour |
| 187 | 25mm PVC Conduit Supply and providing of 25 mm electrical grade ISI heavy duty PVC conduit through wall, ceiling etc. including the supply of all accessorises required. |
| 188 | i)Supply |
| 189 | ii)Labour |
| 190 | 32mm PVC Conduit Supply and providing of 32mm electrical grade ISI heavy duty PVC conduit through wall, ceiling etc. including the supply of all accessorises required. |
| 191 | i)Supply |
| 192 | ii)Labour |
| 193 | 40mm PVC ConduitSupply and providing of 40mm electrical grade ISI heavy duty PVC conduit through wall, ceiling etc. including the supply of all accessorises required. |
| 194 | i)Supply |
| 195 | ii)Labour |
| 196 | 80mm dia Hot Dip galvanised MS conduits Supply and providing of 80mm dia electrical grade ISI Hot Dip galvanised MS conduit through wall, ceiling etc. including the supply of all accessorises required. |
| 197 | i)Supply |
| 198 | ii)Labour |
| 199 | ILLUMINATION & ALLIED WORKS |
| 200 | COMPACT FLUORESCENT & LED LIGHT FITTINGS |
| 201 | Supply and fixing of following surface mounted wall step light . die cast construction and UV stabilized polycarbonate diffuser luminaires of Philips/ Havels / GE make for ceiling including provision of suitable accessories for mounting of fittings, etc. all complete as per specifications and equivalent to Philips cat no. as per details given and direction of Engineer In-charge. (including accessories) a)Havels Cat. No. Endura Magnum 40W LEDor Equivalent |
| 202 | i)Supply |
| 203 | ii)Labour |
| 204 | b) Philips Cat. No. MIROLTA (TMS205 1XTL40W) |
| 205 | i)Supply |
| 206 | ii)Labour |
| 207 | BOLLARD LIGHTS |
| 208 | Supply & fixing ofBollard light fixture with suitable mounting base along with necessary accessories, including excavation upto required depth, giving connections and back filling etc |
| 209 | Philips Cat. No. FGC 100 1XPLS9W |
| 210 | i)Supply |
| 211 | ii)Labour |
| 212 | Hume Pipe |
| 213 | Supplying, laying and joining hume pipes of ISI mark joining specials in existing trenches or ground upto a depth of 1.0 m joining with solvent cement, testing the line etc as required as approved by the site in charge. (Excavation different item) |
| 214 | a)110mm |
| 215 | i)Supply |
| 216 | ii)Labour |
| 217 | b)60mm |
| 218 | i)Supply |
| 219 | ii)Labour |
| 220 | Supply, erection of following sizes GI perforated typecable rack system made out of sheet steel folded to required shape with adequate number of supports. |
| 221 | 200 mm Width perferated type |
| 222 | i)Supply |
| 223 | ii)Labour |
| 224 | b) COST OF ELECTRICAL WORKS FOR MAINTENANCE ROOM |
| 225 | Supply, laying/fixing of earthing conductor of CU flat /wires jointing as per IS; 3043/87 in trench walls pulling through pipes etc as required) |
| 226 | a) Copper wire No.8 SWG (For DB) (CPWD E&M item no.5.17) |
| 227 | CABLE LAYING & END TERMINATION |
| 228 | Supplying and laying the following XLPE insulated PVC sheathed armoured 1.1KV grade Aluminium conductor cable conforming IS: 1554 (Part-I) in cable trenches or on concrete wall or through pipes as per specifications, including providing ofcable route markers in every 50M and at all strategic turning/diversion points etc. Necessary clamping should be provided while burying cables in prepared trenches etc. as instructed by the Site Engineer |
| 229 | a) 4 x 25 Sq.mm. Al cable (D.B incoming cable)(CPWD E&M item no.7.1.1) |
| 230 | Cable End Termination |
| 231 | supplying and terminating siemens type / tropdoor compression gland, Aluminium lugs, earth clamps for XLPE insulated and PVC sheathed armoured conductor cable 1.1kv grade and making end terminations suitable for 2/3/3.5/4 core cables of the following sizes as required |
| 232 | a) 4 x 25 Sq.mm. Al cable (V.D.B incoming cable) (CPWD E&M item no.9.1.34) |
| 233 | FLEXY DISTRIBUTION BOARD |
| 234 | Flexy DB Supplying and fixing of the following way factory made single/three pole and neutral, sheet steel, RCCB Flexy distribution board enclosure, double shuttered on surface /recess complete with tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, cable end box, including painting, earthing etc as required. (IP 42) in recess/in surface including cutting holes on the wall making good the damage colour cleaning etc. as required.The rate should include cost ofmaterials required for DB dressing like cable mount, using proper lugs for incoming and outgoing cable , cable ties, black tape, black buttons, end ferrules, stickers etc., complete.(CPWD E&M item no. 2.5.1) |
| 235 | a)Three phase 4 tier- IP 42 protection metal door Flexy DB (4row of 12 modules) |
| 236 | Incomings of Flexy D.B: |
| 237 | Residual Current Circuit Breaker |
| 238 | Supplying & fixing the following rating miniature circuit breaker of following poles in existing Flexy DB complete with connections, testing and commissioning etc as required. |
| 239 | a) 63A 30mA FPRCCB (CPWD E&M item no.2.15.3) |
| 240 | Outgoings from Flexy D.B: |
| 241 | Miniature Circuit Breaker Supplying & fixing the following rating miniature circuit breaker of following poles in existing Flexy DB complete with connections, testing and commissioning etc as required. |
| 242 | a) (6-32)A SPMCB (Light loads) (CPWD E&M item no. 2.10.2) |
| 243 | WIRING SYSTEM |
| 244 | Wiring Light / exhaust fan pointSupplying all materials and wiring for light points/exhaust fan using 3 runs of1.5mm² 650V grade PVC insulated copper conductor single core FRLS wiresrun continously as per IS through ISIgrade medium gauge rigid PVC conduits concealed in wall / slab etc, complete with necessary accessories, including supplying and fixing 6A modular type switch housed in a suitable factory made M.S box with moulded front plate including earthing the box,3 plate ceiling rose etc. complete as required. (The earth wire shall be green colour)(CPWD E&M item no.1.1.1) |
| 245 | 6A Plug points - combined positionSupplying all materials and wiring for 6A plug points in combined positions using 1.5 sq.mm PVC insulated copper conductor single core FRLS wirerun continously as per IS through ISIgrade medium gauge rigid PVC conduits concealed in wall / slab etc, complete with necessary accessories and fixing 6A modulartype 3 pin shuttered plug socket (2 in 1) controlled by 6A switch with moulded front plate, housed in a suitable factory built MS box.Giving connections, earthing etc complete as required. This circuit shall be looped to the lighting circuit. (CPWD E&M item no.1.5) |
| 246 | 16/ 6A Power plug pointsSupply and providing 16 / 6A combined modular type power plug socket (shuttered) controlled with 16A modular type switch, mounted on a suitable factory built MS box with earthing facility, giving interconnections etc as required. |
| 247 | i)Supply |
| 248 | ii)Labour (LS) |
| 249 | Telephone SystemSupply and laying offollowing pair 0.5 mm² telephonecable through existing conduit .a) 2 pair cables |
| 250 | i)Supply |
| 251 | ii)Labour (LS) |
| 252 | Circuit mains: |
| 253 | a) 3 Runs 2.5 sq.mm. Cu wireSupply and wiring 3 runs of 2.5sq.mm PVC insulated fine stranded FRLS copper wire drawn through 25mm ISI grade rigid/flexible PVC conduits including all accessories as required (For 15A/Gyeser points)(The earth wire shall be of green colour) |
| 254 | i)Supply |
| 255 | ii)Labour (LS) |
| 256 | Conduits: |
| 257 | 20mm PVC ConduitSupply and providing of 25 mm electrical grade ISI heavy duty PVC conduit through wall, ceiling etc. including the supply of all accessorises required. |
| 258 | i)Supply |
| 259 | ii)Labour (LS) |
| 260 | ILLUMINATION |
| 261 | COMPACT FLUORESCENT & LED LIGHT FITTINGSSupply and fixing of following surface mounted wall step light . die cast construction and UV stabilized polycarbonate diffuser luminaires of Philips/ Havels / GE make for ceiling including provision of suitable accessories for mounting of fittings, etc. all complete as per specifications and equivalent to Philips cat no. as per details given and direction of Engineer In-charge. (including accessories) a) Havels Cat. No. Endura Magnum 40W LEDor Equivalent |
| 262 | i)Supply |
| 263 | ii)Labour (LS) |
| 264 | Sub Estimate 2: PROVIDING OPERATION AND MAINTENANCE WORKS FOR FIVE (5) YEARS PERIOD ON COMPLETION OF THE WORK OF “CONSTRUCTION OF FOOT OVER BRIDGE AT KM 9/162 IN INNER RING ROAD NEAR KENDRIYA VIDYALAYA SCHOOL |
| 265 | O& M Maintenance Cost for 5 Years |
| 266 | Housekeeping of FOB Premises a) Housekeeping Women (365 days x 5 years)+1 x 2 Nos |
| 267 | b) Maintenance Supervisor(Incharge) (365 days x 5 years)+1 x 1 No two shifts per day |
| 268 | c) Security Guards 1 Nos. considering 3 shift per day |
| 269 | Escalator Maintenance2 Nos for 5 years |
| 270 | AnnualMaintanance ofpublic service Light duty Escalators / Travellators outdoor type(GS8000-NX) for the period of 5years from the date of commisioning inclusive of First year Free Maintanance Period.A) Routine Maintenance during regular working hours which covers i) Examine the Equipment at regular intervals for 6month service and 6 month service visit with the government regulations existing at the date of this agreement, ii) Clean, adjust, topup oil & grease parts of the equipment as required to maintain the performance of the equipment as close as possible as it was first installed, iii) Report & make recommendations(as may be required) to the owner for any parts repair or replacement as deem necessary, iv) Repair/replacement of parts, components, specifically for equipment control & operation due to fair wear and tear(Materials included) .B) Emergency Call Back Services at any time between regular examinations upon the request of the owner to trouble shoot the Equipment which includes, i) Dispatch as soon as reasonably and practically possible, a trained person to attend any breakdown of the equipment, ii) Use its endeavors to restore the Equipment to operational service without charge, provided always that such restoration would not involve the repair or replacement of parts that arrises from misuse or the negligance of any party, iii) Where any repair or replacement is required during the emergency call back service, such services will be rendered during regular working hours. Other services likei) check for proper operation,abnormal noise, temperature,dust and wear, ii) Clean dust,excess oil,dirt accumulation,carbon deposits, iii) Adjust to compensate gaps due to wear, equalize tension, clearences to within tolerace, Tighten loose connections, iv) Lubricate moving parts and protect from corrosion & v) Repair/Replace of parts like Fuses,relays, PCBs, button & Indicator, switches,wires, terminals, transformers, motor, brake,guides, rollers,bearings,gears , valves, Gear oil, Chain Lubrication oil Etc.,/however any defect shall be rectified within 12 hrs time (Payment will be made as per actual maintenance work done) |
| 271 | a)Escalator 1 |
| 272 | b)Escalator 2 |
| 273 | Lift Maintenance for2 Nos for 5 years AnnualMaintanance of public service 13 personsSTAINLESS STEEL LIFT / ELEVATORS for the period of 5years from the date of commisioning inclusive of First year Free Maintanance Period. |
| 274 | a) Lift 1 |
| 275 | b) Lift 2 |
| 276 | 125KVA Diesel Generator for period of 5 years Maintenancea)Supply of Fuel (Diesel) for running of 125KVA Diesel Generator for period of 5 years to generate power for uninterupted running of Escalators & all other electrical equipments incase of any power shutdown (600 liters/Month),(the consumption will be paid based on actual quantity). |
| 277 | b) AnnualMaintanance of 125 KVA Diesel Generatorfor the period of 5years from the date of commisioning inclusive of First year Free Maintanance Period.All maintenance and repairs as per periodic maintenance chart for Engine in regular use which covers,A) Engine a) Every 50 service hours or every month visit for checking i) Draining water from the fuel tank and fuel pre filter, ii) Retightening the belts,clamps,mounting bolts & nuts, iii) Topup oil & coolant if required, iv) Stop any leakages if observed & v) Check & Topup if required Battery Electrolyte level.b) Every 500 service hours or every six months visit for checking i) Changing engine oil, oil filters, bypass oil filter and fuel filters, ii) Changing governor oil filter & iii) Change coolant filter. c) Every 1500 hours visit for checking i) Inspection of V-belt and adjustment of belt tension, ii) Check and adjust valve clearence & iii) Check sir cleaner restriction and cleanliness. d) Every 2400 service hours visit for checking i) Changing V-belt, ii) Inspection of fuel control linkage ball joints, iii) Inspection and adjustment of fuel injection timing if required, iv) Changing fuel injection timing if required, v) Checking movement of the rack(during operation) of the fuel injection pump(including the governor). B) Value added services like training on maintenance and operations of the DG set to operating staff once in a year, Safety & caution indicators & Reporting oncein 6 months which include a)Details of AMC b)Details of check done C) A comment/suggestion given by a senior service engineer after inspecting and looking into the earlier report of AMC visits to the spot any trend or any indications of possible failure/breakdowns d)Suggestions to enhance the engine life & anyother in all respect for the regular maintenance,however any defect shall be rectified within 12 hrs time.(Payment will be made as per actual maintenance work done) |
| 278 | Electrical Panal & Maintanance Control |
| 279 | a) Cost of consumption of electricity for escalator & lightings (the consumption will be paid based on the actuals) |
| 280 | b) Electrical Panel board & Maintanence control engineer(10days/month,based on the actuals) |
| 281 | c) Electrical Supervisor (1 Nos per Day) |
| 282 | d) Cost for replacement of fused bulbs , replacement of damaged fittings , repair and maintenance of wiring, and electrical fittings etc complete.(the consumption will be paid based on actuals) |
| 283 | CCTV Camera AnnualMaintanance of CCTV Cameras ,Outdoor Camera of 18Nos, Indoor Camera of 1No, PTZ Camera of 1No & its accessories for the period of 5years from the date of commisioning inclusive of First year Free Maintanance Period. The AMC includes Service visit on every month as a periodical maintenance which covers a) Camera Visibility Test, b) DVR Recording Test,c)DVR Settings Verification, d) Disk Error Check, e) product replacement done with same or equivalent product, with in 12 hrs and incaseif any emergency arises which needs to be attended on urgent basis. |
| 284 | Public Address System AnnualMaintanance of Public Address system ,30 Watts Ceiling Speaker 12Nos, Table top goose nec mic of 1No & its accessories for the period of 5years from the date of commisioning inclusive of First year Free Maintanance Period.The AMC includes Service visit on every month as a periodical maintenance which covers a) Amplifier output test, b) Speaker output test ,c)MIC Settings Verification, d) product replacement done with same or equivalent product, with in 12 hrs and incaseif any emergency arises which needs to be attended on urgent basis. |
| 285 | Calculation of SubTotal, GST and Total carried out by system automatically |
| 286 | Sub Total Amount for above all items |
| 287 | GST 18% for the above SubTotal Amount |
| 288 | Total in Figures (SubTotal + GST) |
AI Tender Summary
Tender Timeline
Dec 01, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJan 02, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 03, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender