Tender For Repair Maintenance Of Water Supply Distribution Pipe Line Including Repair Maint Of Solar Water Heaters Electric Panels Including Connected Works Under Ge N Akhnoor, akhnoor-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair Maintenance Of Water Supply Distribution Pipe Line Including Repair Maint Of Solar Water Heaters Electric Panels Including Connected Works Under Ge N Akhnoor. Submission Date for this Tender is 28-12-2022. Solar Heater Tenders in akhnoor Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

35063582
Corrigendum : Tender For Repair Maintenance Of Water Supply Distribution Pipe Line Including Repair Maint Of Solar Water Heaters Electric Panels Including Connected Works Under Ge N Akhnoor
Open Tender
Indian
Jammu And Kashmir
akhnoor
28-12-2022

Tender Details

Tender For Repair Maintenance Of Water Supply Distribution Pipe Line Including Repair Maint Of Solar Water Heaters Electric Panels Including Connected Works Under Ge N Akhnoor

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Dec-2022 Amendment Other 21-12-2022
2 21-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 99900.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR/ MAINT OF WATER SUPPLY DISTRIBUTION PIPE LINE INCLUDING REPAIR/ MAINT OF SOLAR WATER HEATERS, ELECTRIC PANELS INCLUDING CONNECTED WORKS UNDER GE(N) AKHNOOR
Sl. No. Item Description
1Dismantling carefullyeach panel of solar water heater capacity 1000 LPD (each panel of 100 LPD = 10 Nos) including hot and cold pipe line network,collection water tank located between the bldgs at 50 Armd Regtand shifting entire panels and connected water supply tanks, hot water collection tanks on the bldg roof (double storey) and reassembling, reinstallationall as specified and dirceted by Engr-in-charge. Note: 1 Any damage caused during shifting of panels on roof shall be made good by the contractor with replacement. 2All Civil work and replacement and servicingshall be measured and paid separately
2Dismantling carefullyeach panel of solar water heater capacity 200 LPDincluding hot and cold pipe line network,collection water tank located between the bldgs at 50 Armd Regtand shifting entire panels and connected water supply tanks, hot water collection tanks on the bldg roof (double storey) and reassembling, reinstallationall as specified and dirceted by Engr-in-charge. Note: 1 Any damage caused during shifting of panels on roof shall be made good by the contractor with replacement. 2All Civil work and replacement and servicingshall be measured and paid separetly
3M & L for descaling of the collectors and hot water tank 1000 Ltrs Cap with the chemical solvent for removing all silt/rustcomplete and making the whole system leak proof complete all as specified and directed.
4M & L for descaling of the collectors and hot water tank 500 Ltrs Cap with the chemical solvent for removing all silt/rustcomplete and making the whole system leak proof complete all as specified and directed.
5M & L for descaling of the collectors and hot water tank 200 Ltrs Cap with the chemical solvent for removing all silt/rustcomplete and making the whole system leak proof complete all as specified and directed.
6M & L for descaling of the collectors and hot water tank 100 Ltrs Cap with the chemical solvent for removing all silt/rustcomplete and making the whole system leak proof complete all as specified and directed.
7Supply, fabrication and fixing feeder pillarbox of size 500x 450x500 mmmade out of MS sheet of 2.0mm thick bent to shape & size factory made with welding, bending works suitable forand including 200 Amps ratedaluminium bus bars( length of bus bar not less than 40 cm) 4No"s ,makingholes of any size and mounted on porcelain/epoxy based post insulators of appropriate sizewith suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and length of angle iron not less than 1 mtr, 0.5 mtr to be embeded in PCC below G.L and 0.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping.
8Material and labour forheating element ISI markedcapacity3 KW all as specified and directed.
9Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 6 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
10Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
11Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
12Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size25mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP25SMIV Make Anchor or equivalent in Kalinga, supreme
13Taking down UNSVPVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size32 mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP32SMIV Make Anchor or equivalent in Kalinga, supreme
14Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size40 mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP40SMIV Make Anchor or equivalent in Kalinga, supreme
15Material and labour for solar panelhaving 5 mm thick toughned glass size 6"x4" all as specified and directed.
16Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation laying of pole stay assembly and laying of LT/HT cable and getting out in any type of soil complete all as specified and directed by the Engr-in-Charge
17Returning filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in ant type of soil complete all as specified and directed.
18Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point
19Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
20M & L for dry coarse sand as cushioning to cable 8 cm before laying HT/LT cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and directed.
21M&L foraluminium sheet cladding over hot pipe for insulation incl binding clamp all as specified and directed.
22M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surfaceincluding cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. Make of Cable Havells, KEI, Anchor
23Dismantling allelectrical/water connection from IndustrialRO capacity 500 LPH and reconnect afterreplacement of following parts
24(i) Supply only 40x40 membrane ISI marked all as specified and directed.
25(ii) Supply only carbon and sand media all as specified and directed.
26(iii) Supply only20" big blue candle all as specified and directed.
27Supply and fixing Rotational moulded polyethylene water storage tanks capacity 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I® all as specified and directed.
28Supply and fixing Rotational moulded polyethylene water storage tanks capacity 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I® all as specified and directed.
29M&L for Lagging to pipes 25mm dia used in internal water supply or plumbing all round with,40 mm thick bonded mineral wool preformed ‘SNAP ON’pipe sections of density 144Kg/cum con forming to IS 9843 incl chicken mesh and wrapping with 0.01 mm thick aluminium foil all as specified and directed.
30M&L for Lagging to pipes 40mm dia used in internal water supply or plumbing all round with,40 mm thick bonded mineral wool preformed ‘SNAP ON’pipe sections of density 144Kg/cum con forming to IS 9843 incl chicken mesh and wrapping with 0.01 mm thick aluminium foil all as specified and directed.
31M & L for PCC 1:2:4 type C-2(using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete
32S & F angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165.
33Supplying and laying of CPVC pipes size 25mm dia SDR 11 & Plain CPVC SDR 11 fittings in walls/ceilings or in floors complete all as specified and directed.
34Supply and fixing brass elbow size 25mm dia all as specified and directed.
35Supply and fixing brass TEE size 25mm dia all as specified and directed.
36Supply and fixing brass MTA/MBTA size 25mm dia all as specified and directed.
37Supply and fixing brass FTA/FBTA size 25mm dia all as specified and directed.
38Supply and fixing brass ball valve size 25mm dia all as specified and directed.
39Supply and fixing brass unionsize 25mm dia all as specified and directed.
40Supply and fixing brassTank adoptarsize 25mm dia all as specified and directed.
41Supplying and laying of CPVC pipes size 32mm dia SDR 11 & Plain CPVC SDR 11 fittings in walls/ceilings or in floors complete all as specified and directed.
42Supply and fixing brass elbow size 32mm dia all as specified and directed.
43Supply and fixing brass TEE size 32mm dia all as specified and directed.
44Supply and fixing brass MTA/MBTA size 32mm dia all as specified and directed.
45Supply and fixing brass FTA/FBTA size 32mm dia all as specified and directed.
46Supply and fixing brass ball valve size 32mm dia all as specified and directed.
47Supply and fixing brass unionsize 32 mm dia all as specified and directed.
48Supply and fixing brassTank adoptarsize 32 mm dia all as specified and directed.
49Supplying and laying of CPVC pipes size 20mm dia SDR 11 & Plain CPVC SDR 11 fittings in walls/ceilings or in floors complete all as specified and directed.
50Supply and fixing brass elbow size 20mm dia all as specified and directed.
51Supply and fixing brass TEE size 20mm dia all as specified and directed.
52Supply and fixing brass MTA/MBTA size 20mm dia all as specified and directed.
53Supply and fixing brass FTA/FBTA size 20mm dia all as specified and directed.
54Supply and fixing brass ball valve size 20mm dia all as specified and directed.
55Supply and fixing brass unionsize 20mm dia all as specified and directed.
56Supply and fixing brassTank adoptarsize 20mm dia all as specified and directed.
57Supply and installation in repairs, commissioning and testing Polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of ASTA CPRI TEST REPORT IN POLYCARBONATE only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing]. Make-Hensel/Rittal/Emitter/Schneider
58INCOMER:
59Main MCCB 160A 4Pole Breaking Capacity 36KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle– 1 No.
60Digital VAF Meter with Volt,Amp, Frequency – 1 No
61LED Indicator Lamp R,Y,B – 3 Nos
62CT coils 160/5A – 3 Nos
63Control Fuse – 3 Nos
64Outgoings
65MCCB 125A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos.
66MCCB 100A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 2 Nos.
67MCCB 63A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 2 Nos.
68Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundationof pole,laying of pipe line and getting out in any type of soil complete all as specified and directed by the Engr-in-Charge
69Returining filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in ant type of soil complete all as specified and directed.
70Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
71S&F GI water tubing in replacement15mm bore "medium grade", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
72S&F GI water tubing in replacement20 mm bore "medium grade", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
73S&F GI water tubing in replacement25mm bore "medium grade", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
74S&F GI water tubing in replacement 40mm bore "medium grade", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
75S&F GI water tubing in replacement50 mm bore "medium grade", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
76S&F GI water tubing in replacement80 mm bore "medium grade", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
77S&F GI water tubing in replacement100 mm bore "medium grade", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
78S&F GI water tubing in replacement150 mm bore "medium grade", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
79Supply and fixing“Lithium based Energy Efficient Integrated Solar Street Light of 24Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 53/55Wp , Lithium Battery 11.1/12.8V, 28.6AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 12-14kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. Make:- Axxon (AXN-24W) or equivalent in Bajaj /phillips/SURYA/Havells
80Construction of valve pit i replacement ofsizes 120cmx120cmx120cm (internal dimentions), brick construction, including all necessary excavation and earth work in hard/loose soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, PCC in foundation of the mix (1:4:8), type D-2, (using 40mm graded crushed stone aggregate) brick masonry in cement mortar (1:4) rendering, 12 mm thick cement mortar (1:4), internally, finished even and fair pointing flush externaly as the work proceeds in the same mortar, mild steel frame, MS sheet cover 5mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint complete all as specified.
81Construction of brick masonary valve pit in replacement of size 90 x 90 x 90cm (Internal dimensions of chamber from top of PCC to bottom of cover) including excavation in any type of soil returning, filling around foundation and removal of surplus soil to a distance not exceeding 50m PCC 1:4:8 type D2 in foundation brick work in cement mortar 1:6, 10mm thick plaster in cement mortar 1:4 to internal surface covered pit with MS sheet cover 3.15 mm thick with locking arrangement, handle fixing arrangement fixed on 40mm PCC 1:2:4 type B-1 coping and painting with oil paint two coat over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
82Taking down old unsv sluice valve and Supply and fixing ball valve having SS ball with both CI end flanged,ISI marked, with nuts,bolts and washers and rubber gaskets with stainless steel handle over PVC coating complete all as specified and directed for following bore pipe:- Make BVI,BIR,Kirloskar
83(a) 150mm dia
84(b) 100mm dia
85(c) 80mm dia
86(d) 50mm dia
87Supply and fixing non return valve heavy duty both ends flanged ISI marked complete with nuts, bolts washers etc complete all as specified and directed by Engr-in-charge of following sizes:-Make BVI,BIR,Kirloskar
88(a) 150mm dia
89(b) 100mm dia
90Taking out old US gate valve, M&L for ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete of sizes :- Make BVI, BIR,Zoloto,leader
91(a) 15mm bore of pipe
92(b)20mm bore of pipe
93(c)25mm bore of pipe
94(d)40mm bore of pipe
95(e)50mm bore of pipe
96Surface excavation n exc 30cm deep and averaging 15 cm any type of soil all as specified and directed.
97M&L for rolling and consolidating of soling of broken bouldersnot exceeding 15cm thick with power roller exc 5 tonne and nexc 8 Tonne.
98M&L for broken stone boulder hardcore of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface.
99M&L for cement concrete in foundation, filling and mass concrete type D2 1:4:8 40 mm graded (100mm) all as specified and directed.
100M&L for cement concreteT ype B2 1:2:4 40 mm gradedAggrgrate all specified and directed.
101M&L for 80 mm thickness M-40 Grade Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006, jointed and pointed with grey cement and no pigment includingsand cushioning and PCC lock at edges, complete all as specified and directed. Make-Ruchi or equivalent
102Supply, laying and testing in replacement of mild steel ERW pipe line 150 mm dia 5.4mm thickness flanged type confirming to IS 7161 incl MS flanges and rubber gasket with required no of holes, required no nos of MS connecting pieces and required nos of nuts, bolts , washers of suitable sizes incl cutting of pipes weldinfg work and drilling holes incl taking out old CI/DI/MS pipelaid in trenches complete all asspecified and directedMake Electrosteel casting Ltd or equivalent in TATA, JINDAL.
103Supply and fixing Glow sign board made of acrylic sheet reactangular shape having lighting arrangement of superior quality of size 5"x2"x8" showing installation Nomenclature as approvedmarked all as specified and directed. Note: Installation line diagram to be enfaced will be approved by AGE E/M and no extra will be paid of any addition and alteration of words or marking of colours.
104Fabrication of angle stand made of angle size 50x50x6mm for Glow sign board, incl jointing of Tees,incl PCC for foundation all as specified and directed
105Supply and fixing in replacement connection cable multistranded single core PVC insulated copper conductor cable incl PVC conduit pipe from starter to motor or vice versa of size of cable 120 sqmm complete all as specified and directed by Engr in charge
106Surface dressing in hard/dense soil n exc averaging 15cm deep for cleaning the area by cutting the unwanted bushes/vegitation growth in and around the area of installations/around the valve pit chamber/along the pipe line route if required etc all as specified and directed.
107One coat of S/E paint on old steel surfaces including preparation of old painted surfacenot otherwise described over 10 cm width or girth complete all as specified and directed by Engr-in-Charge.
108Taking down unsv false ceiling and supply and fixing anodised aluminium snap grid frame work for false ceiling size of grid 605 x 605 mm with 12mm perforated particle board /tiles of size 600mmx600mm complete with GI Hangers adjusted level fixed to roofs slabs by means of ceiling cleats made out of GI flat and fasteners 12.5 mm dia , 40mm long complete all as specified.
109Supply and fixing of DWC HDPE tubing 50 mm bore for open/underground laying cable, cut to size and making thetubing forcable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate withUV rays/ heavy sun rays/winter season etc. (c)Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates
110Supply and fixing of DWC HDPE tubing 80 mm bore for open/underground laying cable, cut to size and making thetubing forcable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate withUV rays/ heavy sun rays/winter season etc. (c)Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail