}

Tender For Supply Installation Testing Commissioning Of Fire Related Works In Rrs Building At Actrec, kharghar-Maharashtra

Tata Memorial Centre has published Tender For Supply Installation Testing Commissioning Of Fire Related Works In Rrs Building At Actrec. Submission Date for this Tender is 20-12-2022. Machine Tools Tenders in kharghar Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

35061293
Tender For Supply Installation Testing Commissioning Of Fire Related Works In Rrs Building At Actrec
Open Tender
Indian
Maharashtra
kharghar
20-12-2022

Tender Details

Tender For Supply Installation Testing Commissioning Of Fire Related Works In Rrs Building At Actrec - Supplying, fixing, connecting, testing and commissioning of Self Contained Rechargeble LED Emergency signs with the following featuresMaintained type, Surface mounting/ hanging type, multi LED which provides illumination on normal mains power supply and the same lamp coutinues to provide illumination during mains failure on self contained battery source for HRTAL areas for Escape. ON resumption of mains supply, the lamp switches back to the mains automatically and simultaneously starts recharging the battery to the requred level, LED Escape Route Light with LED lamp fitting with 3 hours backup with rechargable Ni-Mh/ Ni-cd/Le-ion battery, Directional as requred, paint & colour in epoxy polyester powder coating, white in colour., made up of CRCA Sheet steel/Aluminium-22 SWG, with 8-10 hours recharging period with built in constant current charger. Input - 230V, 50 Hz, CE Certified, ROHS Certifide, Confirms to IS: 10322. 3 `EXIT Signages 4 Exit Directional Signages 5 Wiring for Signages with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit as required 6 Internal Fire Hydrant System - Starter panel at ground floor for Booster pump and Pressure gauge 7 Supplying, installing, testing & commissioning of push button station (should be parallel) at Ground floor for Terrace Booster pump of 900 LPM at terrace level. (Control panel for Terrace Booster pump is already installed at terrace level.) 8 Supplying & laying of 4 core, 2.5 sqmm unarmoured copper cable, XLPE, with fixing termination considering alonwith all accessories 9 Supplying, installing, testing & commissioning of UL/ FM approved Pressure Gauge on hydrant pipe at terrace level of 100 mm dia., liquid filled 0-10 bar. Fitted with 15 mm dia. root cock valve, and G.I. pipe, elbow, snubber, process piping etc. as per requirement in an approved manner and Ball Valve. 10 SITC of Cast iron butterfly valve with Tamper Switch rated for pressure rating PN 16 kg/sqcm standard pattern (Horizontal / Vertical),with necessary flanged joints by providing necessary pair of M.S. flanges, nuts, bolts, gaskets, etc. complete with all aspect. 11 150 NB 12 Fire Sprinklers in Kitchen Area 13 Dismantling the existing Pendant sprinklers with flexible hoses and shut off with a plug. Sprinklers handed over to TMC. 14 Dismantling the existing Upright sprinklers and handed over to TMC. 15 Supplying, installing, testing & commissioning of Upright equivalent, UL/FM certified, SRSC sprinklers at kitchen area, chrome finish, K-factor-80, Temperature-93 Deg C, 1/2 NPT. 16 Fire Alarm System- Relay modules for Fans 17 Supplying, Installing, testing & commissioning of addressable, UL listed, Relay Module for Terrace level Exhaust fans/ staircase press fans, loop powered, class A wired, low quiescent current,Rotary/ DIP decimal address setting switch, 24V DC (15-32V), suitable for surface / recess installation, housing & wiring box, In/Out loop cable glands & used for switching on/ off electrical fans. 18 Supply, Installation, Testing, Configuring in Software, Commissioning of power supply unit from 230 V UPS to 24 V DC, 6A power supply for notification for Analogue Addressable System. 19 Supplying & installing of 2 pair Loop Data Cable 300/500V, stranded annealed tinned copper, 7/0.53mm, 1.5 Sqmm, PVC insulation type C of IS 5831, Mylar backed aluminum screened with 25% overlap & 100% screen Inner extruded ST-2 sheath, single armoured, PVC St-2 extruded outer sheath with FRLS, to BS 5308. 20 Supplying, Configuring in Software of2 core, 1.5 Sqmm Control Cable, 1.1kV for Modules to Devices. 21 CRMs to fan starters 22 24 V DC Power supply to 10 CRM 23 Supplying and fixing of following sizes of 25 mm dia. rigid PVC conduit alongwith accessories in surface (medium)/ recess (heavy) including cutting the wall and making good the same in case of recessed conduit as required. (For power cables- alarm & push button starter) 24 Fire Alarm System - Utility Block 25 Supplying, installing, testing & commissioning of UL listed analogue addressable false ceiling/ flush on roof slab mounted Multi-Sensor Photoelectric Smoke Detector 0.5-1-2-3-4%/Ft & heat smoke at 570 C fixed element, 24V DC 300µA quiescent & 6.5 mA operated, status LEDs, Rotary switch/DIP switch addressing including with mounting base, wiring back box, all cabling, glands & terminations, complete.Refer Technical Specifications 26 Supplying, installing, testing & commissioning of Analogue Addressable UL listed Manual Pull Station/ Break Glass Unit, loop powered, 22V DC operating current, 600µA quiescent currentwith facility to programme the device from 01-159 with the help of dip/ rotary switches, complete with IP 24 housing with gland, Status LED for polling / fire condition etc.as required,Rotary switch/DIP switch hardware addressinginstalledin recess/ wall/ column including all cabling & terminations & glandsRefer Technical Specifications 27 Supplying, installing, testing & commissioning of Analogue Addressable UL listed Strobe Sounders, 95 dB at 1 M output with 2 volume & 3 tone settings @ 75mA cum strobe with 15-75-115 candela settings at 75mA, 1Hz flash / second, rendered preferably suitable for selective operation through powered loop powered (externally powered may be accepted) with 24 V DC supply, installed in recess/ wall/ column including all cabling & terminations, complete as required with housing & cable glands on mounting backbox etc.Refer Technical Specifications 28 Supplying, installing, testing & commissioning of UL listed loop powered bidirectional Fault Isolator Module, 24 V DC, 400 µA quiescent & 17 mA in fire conditions, installation on addressable loop after every 15-20 detectors/ devices for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement complete with wiring back box with cable glands, base etc.Refer Technical Specifications 29 Supplying, installing, testing & commissioning of UL listed analogue addressable loop powered Monitor Module 20.5 V DC, 700 mA operated & 600 µA quiescent, rotary/ dip switch address setting, installed in recess/ wall/ column including all cabling & terminations & base wiring box.Refer Technical Specifications 30 Supplying, installing, testing & commissioning of UL listed analogue addressable loop powered Control Module 20.5 V DC min , 700 mA operated & 600 µA quiescent, rotary/ dip switch hardware address setting,installed in recess/ wall/ column including all cabling & terminations & base wiring box.Refer Technical Specifications 31 Supplying, Configuring in Software of2 core, 1.5 Sqmm Copper armoured Cable, 1.1kV forDevices.Refer Technical Specifications

Key Value

Document Fees
Refer document
EMD
INR 27211.0 /-
Tender Value
INR 13.60 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail