Tender For Repair / Replacement And Maintenance Ro Plants, Solar Water Heating System, Geyser And Other Connected Work At Banihal And Kishtwar Under Ge (I) 873 Ews, Kishtwar-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair / Replacement And Maintenance Ro Plants, Solar Water Heating System, Geyser And Other Connected Work At Banihal And Kishtwar Under Ge (I) 873 Ews. Submission Date for this Tender is 09-01-2023. Solar Heater Tenders in Kishtwar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

35046147
Corrigendum : Tender For Repair / Replacement And Maintenance Ro Plants, Solar Water Heating System, Geyser And Other Connected Work At Banihal And Kishtwar Under Ge (I) 873 Ews
Open Tender
Indian
Jammu And Kashmir
Kishtwar
09-01-2023

Tender Details

Repair / Replacement And Maintenance Ro Plants, Solar Water Heating System, Geyser And Other Connected Work At Banihal And Kishtwar Under Ge ( I ) 873 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Dec-2022 Corrigendum No 1 Date 27-12-2022
2 16-Dec-2022 Corrigendum No 2 BOQ 27-12-2022
3 27-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-01-2023
4 03-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 10 Lakhs /-

BOQ Items

Name of Work : REPAIR / REPLACEMENT AND MAINTENANCE RO PLANTS, SOLAR WATER HEATING SYSTEM, GEYSER AND OTHER CONNECTED WORKAT BANIHAL & KISHTWAR UNDER GE (I) 873 EWS
Sl. No. Item Description
1Dismantling and refixing the complete unit of unserviceable solar water heater plate with new solar water heater plate of the following installed at various sites complete overhauling, cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as copper tubes, toughned glass, hot water tank, nuts, bolts, wasahers and all other minor accessories as required at site including painting to solar water heater by rubbing the old paint and applying with two coats of synthetic enamelled paint by spray painting and testing the same after repair, complete all as specified and directed ;- a) Capacity 300 LPD (Note: Replacement of spares shall be measured and paid for seperately.)
2b) Capacity 500 LPD
3c) Capacity 1000/2000 LPD
4Supply only the following items / spares in replacement for Solar Heaters of various capacities as mentioned in serial Ni. 1 here-in-before complete all as specified :- (a) Heating element (Electric rod) of capacity upto 2 KW having rubber washer of size 1 ¼” or 1 ½”complete.
5(b) Glycol (Anti freezing solution) for filling in copper tubes complete.
6(c)Coupling gasket
7(d)Hot rubber pipe of 20mm dia complete
8(e)Float valve assembly 25mm dia complete.
9(f) Thermostat suitable for solar heater complete.
10(g) Dead flange with nut, bolts and washers complete.
11(h)Temp Gauge 0 degree centigrade to 120 degree centigrade
12Taking up or down old unserviceable 15mm dia Galvanised Iron Water Pipe (including all fittings) laid in trenches/on walls / floors / ceilings with clamps complete all as directed.
13Taking up or down old unserviceable 20mm dia Galvanised Iron Water Pipe (including all fittings) laid in trenches/on walls / floors / ceilings with clamps complete all as directed.
14Taking up or down old unserviceable 40/50mm dia Galvanised Iron Water Pipe (including all fittings) laid in trenches/on walls / floors / ceilings with clamps complete all as directed.
1515mm dia Galvanised iron pipe medium grade with all fittings such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc. supplied and laid in trenches/on walls / floors / ceilings wih clamps complete all as specified and directed Make : Jindal / TATA / Prakash Tubes
1620mm dia Galvanised iron pipe medium grade with all fittings such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc. supplied and laid in trenches/on walls / floors / ceilings wih clamps complete all as specified and directed Make : Jindal / TATA / Prakash Tubes
1725mm dia Galvanised iron pipe medium grade with all fittings such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc. supplied and laid in trenches/on walls / floors / ceilings wih clamps complete all as specified and directed Make : Jindal / TATA / Prakash Tubes
1840mm dia Galvanised iron pipe medium grade with all fittings such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc. supplied and laid in trenches/on walls / floors / ceilings wih clamps complete all as specified and directed Make : Jindal / TATA / Prakash Tubes
1950mm dia Galvanised iron pipe medium grade with all fittings such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc. supplied and laid in trenches/on walls / floors / ceilings wih clamps complete all as specified and directed Make : Jindal / TATA / Prakash Tubes
20Sheet metal enclosure factory made single door for DB 240 volts with 200 Amps rated bus bar SPN 4 Way including taking down and making good disturbed surfaces of walls, complete all as specified and directed.
21MCB SPN 32 Amp 10 KA 240 Volts, 50 Hz, "C" curve complete all as specified and directed.
22MCB SP 6 to 32 Amp 10 KA 240 Volts, 50 Hz, "C" curve,complete all as specified and directed.
23On-site Repair / Maintenance and Servicing of RO/filteration plants by dismantling, checking all parts i.e. Pre-filter, granular activated carbon block filter, membrane, UV disinfection / filtration system, adaptor, pressure pump set, main pump motor, solenoid valve, flow controller, all gauges, filling of anti-scalent liquid, checking functioning of all type meters, electric wiring, contactors & relay, switches, valves and replacement of old unserviceable parts, checking of leakages of any part of plants and pipe line by new parts and pipe line including re-assembling the same as original and reinstalling at same place includingre-connecting with the existing water supply systemand testing at full capacity discharge of filtered water complete all as specified and as directed of the following description :- (a) RO Plant of 150 Ltrs/Hours capacity
24(b) RO Plant of 250 Ltrs/Hours capacity
25(c) RO Plant of 500 Ltrs/Hours capacity
26(d) RO Plant of 2500 Ltrs/Hours capacity
27(e) RO Plant of 5000 Ltrs/Hours capacity Notes for Serial Item No 13 :- (i). Spare parts required for replacement of the defective parts to make the RO Plant fully functional shall be measured and paid separately under appropriate item of this Schedule as "Supply only". (ii). The Contractor will ensure that all RO plants are functional throughout the contract period by detailing his technical team once in each quarter though out the contract period for servicing and maintenance.
28(iii). In the eventually of any RO plants not working after the last service and before the next service, the contractor will attend the complaint within 72 hours of intimation of the complaint through SMS / e-mail / WhatsApp message from JE (E/M) / AGE (E/M). The Visit charge due to any such complaint shall be deemed to be included in the quoted rates against Serial item No 36 & 37 and nothing extra shall be admissible on this account. (iv). In case the Contractor fails to attend the complaint and does not make the plant serviceable within stipulated time frame of 72 hours, a Panel Recovery of `500.00 per day per plant will be deducted for each day of delay. (v). The Contractor may claim part payment for each quarter as per the work done. Contractor shall produces Job card duly indicating details of parts replaced duly signed by the User Rep, JE (E/M) & AGE (E/M).
29Repair / Maintenance of feeding Pump of 0.37KW to 0.5HP installed in RO plant at various location by disconnecting of RO plant carefullyfor repair, rewindingwith super enamelled copper winding wire of suitable size, greasing, change of capacitor, bearing etc and reassembling of pump at its original position, complete all as specified and directed.
30Repair / Maintenance of Pressure Pump of 1 to 2 HP installed in RO plant at various location by disconnecting of RO plant carefullyfor repair, rewindingwith super enamelled copper winding wire of suitable size, greasing, change of capacitor, bearing etc and reassembling of pump at its original position, complete all as specified and directed.
31Supply only Feeding Pump suitable for small water filtration plant of rating 0.37 KW/ 0.5 HP, 230 volts, 50 Hz, Single Phase, 20 meter head and discharge rate 40 LPM, complete all as specified and directed. Make : Crompton Greaves / Kirloskar / Siemens
32Supply only Pressure Pump suitable for small water filtration plant of rating 0.75/1.0 KW/HP, 230 volts, 50 Hz, 3 stage& discharge rate 750 LPH, complete all as specified and directed. Make : Crompton Greaves / Kirloskar / Siemens
33Supply only Pressure Pump suitable for small water filtration plant of rating 1/1.50 KW/HP, 230 volts, 50 Hz, 5 stageand discharge rate 750 LPH, maximum head 47 meter, complete all as specified and directed. Make : Crompton Greaves / Kirloskar / Siemens
34Repair / maintenance / replacement of control unit with replacement of defective parts of RO plant of capacity 50/150/250 LPH all as specified and directed.
35Supply only Pre-Filter (Micronic Filter) candle of following size, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) (a) RO Plant of 150 Ltrs/Hours capacity
36(b) RO Plant of 250 Ltrs/Hours capacity
37(c) RO Plant of 500 Ltrs/Hours capacity
38Supply only Carbon block Filter of following size, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) (a) RO Plant of 150 Ltrs/Hours capacity
39(b) RO Plant of 250 Ltrs/Hours capacity
40(c) RO Plant of 500 Ltrs/Hours capacity
41Supply only Membranes of following capacity, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) (a) RO Plant of 150 Ltrs/Hours capacity
42(b) RO Plant of 250 Ltrs/Hours capacity
43(c) RO Plant of 500 Ltrs/Hours capacity
44Supply only ultra violet system 150 LPH / 250LPH RO plant, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
45Repair / maintenance / replacement of control panel and its parts inclusive paint, making identification marks of all indicators like pressure gauge, Ammeter, Voltmeter etc all defective parts to be replaced and make in serviceable codition all as specified and directed. (Note:- All required replacement of parts in panel will be inclusive in quoted rate of this job. No extra cost of parts will be pay to contractor)
46Supply only distributor handle of following capacity, complete all as specified and directed. (Make : Renuka / Kent/ Eureka Forbes / Hi Tech) (a) RO Plant of 150 Ltrs/Hours capacity
47(b) RO Plant of 250 Ltrs/Hours capacity
48(c) RO Plant of 500 Ltrs/Hours capacity
49(d) Filteration Plant of 2500 Ltrs/Hours capacity
50(e) Filteration Plant of 5000 Ltrs/Hours capacity
51Supply only new Adaptors of following capacity, complete all as specified and directed. (Make : Renuka / Kent/ Eureka Forbes) (a) RO Plant of 150 Ltrs/Hours capacity
52(b) RO Plant of 250 Ltrs/Hours capacity
53(c) RO Plant of 500 Ltrs/Hours capacity
54Supply only Media Cylinder of following capacity, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) (a) RO Plant of 150 Ltrs/Hours capacity
55(b) RO Plant of 250 Ltrs/Hours capacity
56(c) RO Plant of 500 Ltrs/Hours capacity
57(d) Filteration Plant of 2500 Ltrs/Hours capacity
58(e) Filteration Plant of 5000 Ltrs/Hours capacity
59Supply only flow restrictor adjuster of following capacity, complete all as specified and directed. (Make : Renuka / Kent/ Eureka Forbes) (a) RO Plant of 150 Ltrs/Hours capacity
60(b) RO Plant of 250 Ltrs/Hours capacity
61(c) RO Plant of 500 Ltrs/Hours capacity
62Supply only chemical dozing system (AD system for antiscalent liquid) for RO plant, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
63Repair / servicing of chemical dosing electric operated at site replacement of unservieable spares ie. NRV, inlet outlet pipe, strainer, foot valve, regulator, indicator switch as required and make in serviceable codition all as specified and directed. (Note:- All required replacement of parts will be inclusive in quoted rate of this job. No extra cost of parts will be pay to contractor)
64Supply only micronic shell (Filter housing) of size 20 inch complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)
65Supply only micronic shell (Filter housing) of size 10 inch complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)
66Supply only anti-scalant liquid (memrance protector) complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)
67Supply only Bib tap 20mm bore standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 125 grams), complete all as specified and directed.
68Supply only Bib tap 15mm bore standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 90 grams), complete all as specified and directed.
69Supply only bib tap, cast copper alloy, 15mm bore, screweddown, high pressure with crutch or butterfly handle, both ends screwed for iron pipe orfor union etc., complete all as specified and directed.
70Supply only Stop Valve, cast copper alloy, 15mm bore, screweddown, high pressure with crutch or butterfly handle, both ends screwed for iron pipe orfor union etc., complete all as specified and directed.
71Supply only Stop Valve, cast copper alloy, 15mm bore, screweddown, high pressure with crutch or butterfly handle, both ends screwed for iron pipe orfor union etc., complete all as specified and directed.
72Supply only PVC tubing of 14mm bore, complete all as specified and directed. Make :Renuka/ Kent / Eureka Forbes
73Supply only PVC tubing of 12mm bore, complete all as specified and directed. Make :Renuka/ Kent / Eureka Forbes
74Supply only CPVC pipe of outer dia 16mm bore, complete all as specified and directed. Make :Renuka/ Kent / Eureka Forbes
75Supply only CPVC pipe of outer dia 20mm bore, complete all as specified and directed. Make :Renuka/ Kent / Eureka Forbes
76Supply only brass elbow for CPVC of 16mm size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
77Supply only brass elbow for CPVC of 20mm size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
78Supply only CPVC union of 16mm size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
79Supply only CPVC union of 20mm size, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
80Supply only capacitor of 10 MFD, complete all as specified and directed. Make : L&T / ABB / Siemens / GE
81Supply only capacitor of 30 MFD, complete all as specified and directed. Make : L&T / ABB / Siemens / GE
82Supply only Solenoid Valve, complete all as specified and directed. Make : Renuka / Kent / Eureka Forbes
83Supply only CPVC pipe Adhesive, complete all as specified and directed.
84Supply only Taflon Tape for RO, complete all as specified and directed.
85Repair and maintenance of control unit of filteration plant of capacity 2500 LPH all as specified and directed.
86Supply only DOL starter for 1 to 2 HP capacity electric motor complete and taking down old unserviceable Starter all as specified and as directed. Make : L&T / Havells / Legrand / ABB / C&S
87Submersible flat cable PVC insulated and PVC sheathed LT 1100 volts grade with copper conductor of size 16 Sqmm 3 Core, complete all as specified and directed. Make : Havells / Finolex / Polycab / Plaza / Asian
88Disconnection of 12.5 HP centrifugal pump set motor kit from inside the water supply sump from delivery pipe, lifting, transportationto approved workshop for repair/rewinding with supper enamalled copper winding wire of same size, insulation material ie. PVC copper cable lead, glass fibre sleeves, cotten tape, insulation paper, varnish and bearing grease etc, & reassembling of motor after rewinding the same and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections including necessary nuts, bolts, washers etc., required at site of work, complete all as specified & directed
89Material and labour for rewinding of damaged/burnt motor of capacity 1 H.P to 20 H.P any type by using enamelled copper wire of superior quality of existing grade and same Nos. of turns including varnishing ‘F’ class insulation and drying in heat chamber / oven including all other material / fittings and testing on completion, complete all as specified & directed.
90Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzsuitable for 12.5 HP motor having protection against single phase with provn of volt/Amp meter, indicators, selector switches, push ON/OFF switch completeincluding making necessary connections and taking down old unserviceable Starter all as specified and as directed. Make : L&T / Havells / Legrand / ABB / C&S
91Supply & Filling Chlorine Dosing Tank of RO/Filtration plaant of SUPER CHLOR TOTAL a solution of Hypochlorous Acid (HOCL) for chlorination of drinking water disinfection solution having residual effect, clear colour less and potent germicide non corrosive and non foaming stable upto 100 degree C for drinking water as and when required in HDPE jericane of 35 Ltrs capacity having the following features (Make : Renuka Tech) (a) Potent germicide (b) Slime control (c) High residual effect to avoid contaminator (d) Less Hazardous (e) Work at low dosage in post disinfection (f) No after taste (g) Most reliable in operation (h)Eco friendly and biodegradable
92Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
93Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
94Removing excavated soilsto a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail