Tender For Repair And Maintenance Of Ac Plant Ducting, Cooling Appliances, Split Type Ac, Window Ac, Water Cooler, Refrigerator, Deepfreezer, Desert Cooler, Voltage Stabilizers And Misc Items At 2Wing Air Force Station Pune, pune-Maharashtra

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Ac Plant Ducting, Cooling Appliances, Split Type Ac, Window Ac, Water Cooler, Refrigerator, Deepfreezer, Desert Cooler, Voltage Stabilizers And Misc Items At 2Wing Air Force Station Pune. Submission Date for this Tender is 19-12-2022. Voltage Stabiliser Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

35044901
Corrigendum : Tender For Repair And Maintenance Of Ac Plant Ducting, Cooling Appliances, Split Type Ac, Window Ac, Water Cooler, Refrigerator, Deepfreezer, Desert Cooler, Voltage Stabilizers And Misc Items At 2Wing Air Force Station Pune
Open Tender
Indian
Maharashtra
pune
19-12-2022

Tender Details

Repair And Maintenance Of Ac Plant Ducting, Cooling Appliances, Split Type Ac, Window Ac, Water Cooler, Refrigerator, Deepfreezer, Desert Cooler, Voltage Stabilizers And Misc Items At 2Wing Air Force Station Pune

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF AC PLANT DUCTING, COOLING APPLIANCES, SPLIT TYPE AC, WINDOWAC, WATER COOLER, REFRIGERATOR, DEEPFREEZER, DESERT COOLER, VOLTAGE STABILIZERS AND MISC ITEMS AT 2WING AIR FORCE STATION PUNE
Sl. No. Item Description
1M&L for Servicing, cleaning of complete unit (indoor and out door) of air cooled split type AC ofany capacity by using blower, cleaning of condenser coil with water, checking all the parts, electrical connection , cleaning the air filters, combing of fins by using fins comb includingreplacing defective filters, burnt wiring, tightening of electric wiring connections, etc,complete all as specified and directed.
2M&L for replacement of existing old U/S insulation of refrigerant pipes of spit air conditionerup to 3 TR cap complete all as specified and directed.
3M&L for replacement of micro processor printed circuit board complete suitable for split type AC"s as per exiting make & model up to 3 TR Cap complete all as specified and directed.
4M&L for replacement of unsv PCB of indoor/outdoor unit of Inverter type AC as per existing make & model complete all as specified and directed.
5M&L taking out defective micro processor printed circuit board of split type AC of existingMake/Model up to 3 TR Capacityfor repair and refixing to its original place after carry out necessary repair and testing complete all as specified and directed.
6M&L for replacement of unserviceable starting capacitor suitable of window type/split type AC"sup to 3 TR Capacity as per existing cap complete all as specified and directed.
7M&L for replacement of unserviceable running capacitor 30/36/40/45/55 mfdsuitable for split/window type AC"s1 to 3 TR cap of existing make & model complete all as specified and directed.
8M&L for replacement of capacitor 4/6 mfd suitable forfan motor of (split/window /water cooler/Desert cooler fanmotor) complete all as specified and directed.
9M&L for replacement of unserviceable swinging motor of indoor unit of split type AC up to 3TR capacity suitable for existing make/model complete all as specified and directed.
10M& L for replacement of condenser fan/blower motor with bush and washers as per existing make and model for split type AC up to 3 TR Capacity complete all as specified and directed.
11M&L for replacement of existing unsv compressor unit with new Compressor unitas per existing make & modelincludingtakingout the old u/s burnt out Compressor of split type Air Conditioner, unsvreplacement ofbushes, sleeves, washers nut and bolt, relay terminal cover, clips reqd for fixing of new compressor, cutting, brazing of copper piping, charging of suitable refrigerant gas as required Qty to obtained desired cooling, carry out leak test etc., all as required at site completeforfollowing capacity:- Existing Make: Emerson/Carrier/ Tecumsha/ LG/Voltas
12Capacity 1.5 TR
13Capacity 2.0 TR
14Capacity 3.0 TR
15M&L for replacement of unserviceable fan blade of condenser unit of split type AC up to 3 TR as per existing make and model complete all as specified and directed.
16M&L forleakdetection by nitrogen pressure test in refrigerant system of AC, cutting brazing and making leak-proofthe gas system, cleaning, vacuum thegas system and charging suitable gas as required quantity to achieve desire cooling complete all as specified and directed.
17Split type AC1.5 TR capacity
18Split type AC2.0 TR Capacity
19Split type AC 3.0 TR capacity
20M&L for replacement of unsv contactor kit of split type AC as per existing make & modelup to 3 TR complete all as specified and directed.
21M&L for replacement of unsv copper tubing5/8" dia complete all as specified and directed.
22M&L for replacement of unsv copper tubing 3/8" dia complete all as specified and directed.
23M&L for replacement of unsv power cable cord PVC flexible copper wire2.5 sqmm 3 core complete all as specified and directed.
24Labour only forrectification of water leakage problem by cleaning indoor unit & drain pipe of split type AC up to 3 Ton cap complete all as specified and directed
25M&L for replacement of unsvvalve of split type AC of existing make up to 3 TR cap complete all as specified and directed.
26M& L for replacement of unserviceable hermetically sealed/rotary compressor with new Compressor suitable for window type AC of following capacity, including replacement of unserviceable bushes, sleeves, washers nut and bolt ,foundation legs including relay terminal cover and clips and including cutting, brazing, leak detection, charging of suitable refrigerant gas as required to obtained desired cooling, carry out leak test etc.,all as required at site complete commissioning, testing for the following capacity Existing Make-Emerson/Carrier/ Tecumsha/ LG/Voltas
27Compressor suitable for 1.5 TR Capacity
28Compressor suitable for 2.0 TR capacity
29M&L for servicing, cleaningof window type AC"s of capacity 1.0/1.5/ 2.0 TR by blower, cleaning condenser coil with water, combing finsincluding replacement of defective filter, selector knobs, burnt wiring , tighting, checking of electrical connections etc. complete all as specified and directed.
30M&L for replacement ofunserviceableelectric blower motor suitable for 1/1.5 /2TR capacitywindow type AC double speed, single phase 230 volt 50 Hz, complete all as specified and directed.Make - Gulmarg/AUE or as per existing make/ type.
31M&L for replacement of unserviceable thermostat switch suitable for water coolers, Window typeAC"s /split AC"s, refrigerators and Deep freezersany capacity, make & model all as directed.
32M&L for replacement of starting relay suitable for water coolers, Window typeAC"s /split AC"s, refrigerators and Deep freezersany capacity, make & model complete all as specified and directed.
33M&L for replacement of existing unsvfan motor of desert coolers up to 6000CFM as per existing model & speed including taking outthe old /unserviceable motor complete all as specified and directed.
34M&L for replacement unservicable water pump of desert cooler with submersible type water pump0.6 KW, 1.25 m head pump complete all as specified and directed.
35M&L for replacement of Khas pad (set of three)with best quality new pad, fordesert coolers of 4000/5000 cfm capacity complete all as specified and directed.
36M&L for replacement of fan speed control switch of Desert cooler up to 6000 CFM PVC bodyunit as per existing make & model complete all as specified and directed.
37M&L for replacement of Louvers control knob switch of Desert cooler up to 6000 CFM PVC bodyunit as per existing make & model complete all as specified and directed.
38M&L for replacement of unsv fan blade of desert cooler up to 6000CFM as per existing type make & model complete all as specified and directed.
39M&L for replacement of honeycomb pads of desert cooler up to 6000CFM as per existing complete all as specified and directed.
40M&L for replacement of desert cooler body 66x660x900 mm with front grill and three side louver fabricatedout of 22 gauge mild steelplan blacksheet and bottomwater tank(sump) of size 660x660x200 mm deep fabricated out of 20 gauge milled steel plan blacksheet including takingout and reinstallationcomplete with standard fittingsuch as pvc pipe forwater electric motorand fan motor clamp for motor,switch fan speed regulatorincluding fixingand connctingexistingcooler fan electric pump with core pvcinsulated & pvc sheathed cable (min 3 mtr in length External surface shall bespray painted withapproved paint over a coat of red oxide primerand internall surfaceofbody cooler pump and motor shall bepaint with two coat of bituminous paint over a coat of red oxide primer complete all as specified and directed.
41M&L in replacement of 01Nos front grill and 3 side louverssuitable fordesert cooler duly spray painted with approved paint overa coat of redoxide primer and internal surfac of body coolerpump and motor shall bepainted with two coat of bituminous paintover a coat of red oxideprimercomplete all as specified and directed.
42M&L for servicing of water cooler of installed capacity40/40to 150/150 Ltrs, cleaning the tank, condenser coil, oiling the fan motor, checkingall parts, repair to electrical burnt/loose connection, replacement of rubber gasket, washer minor u/s parts etc. all as specified and directed.
43Supply and fix hermetically sealed unit new Compressor by dismantling burnt out u/s Compressor suitable for water coolers of following capacitiesincluding provn ofbushes, sleeves, washers nut and bolt for 4/3 Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing for the following capacity:- Make of Existing Water Cooler : Emerson/Carrier/ Tecumsha/ LG/Voltas
44Cooling capacity 40 Ltrs/Hr
45Cooling capacity 60 Ltrs/Hr
46Cooling capacity 150 Ltrs/Hr
47M&L for replacment of freezer of refrigerator as per existing make model including cutting, brazing complete all as specified and directed of cap 192 to 385 Ltr
48S&F push cock CP brass of 15 mm dia for water cooler and taking out the unserviceable push cock and complete all as specified and directed.
49M&L for replacement of unsv float valve for water cooler (40/60/120/150 Ltrs) capacity any as per existing size and type complete all as specified and directed.
50Servicing of air curtains, single phase, 240V by checking all electrical connection, blower, motor oiling greasing and replacement of u/s wire, lugs, bushes, rubber pads, bearing etc. complete all as specified and directed.
51M&L for replacment ofhermetically sealed/Rotarey Compressor by dismantling burnt out u/s Compressor suitable for refrigeratorsincluding provn ofbushes, sleeves, washers nut and bolt for 4/3 Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing for the following capacity. ( Existing Make : Emerson/Carrier/ Tecumsha/ LG/Voltas)
52165 - 200Ltrs capacity
53285 - 300 Ltrs capacity
54M&L forleakdetection in refrigerant system ofRefrigerator (165 to 300 Ltrs cap) including cutting brazing and making leak-proofthe gas system, cleaning, vacuum thegas system and charging suitable gas as required quantity complete all as specified and directed.
55Taking out existing split type air conditioners of any type and capacity removing from the site and keeping it in a safe custody for re-use or deposit in store complete all as specified and directed.
56Fixing only split type air conditioners of any type and capacity including core cutting for passing copper tubing , drain pipe & cable through stone masonry wallwith connected accessories such as bracket, copper tubing, cable from indoor to out door unit and rain water pipe etccomplete all as specified and directed.
57M&L for replacement of old unsv outdoor unit of split typewith AC 3 star rating, 1.5 TR Cap having copper tubing, high EER rating compressor (for gas R-407/410/32), blower motor etc. complete including, making elect, refrigerant piping connection, brazing, leak testing and chargingsuitable refrigerant gasto achieve desired cooling effect and testing complete all as specified and directed. Existing Make- Blue Star/Voltas/Hitchin/Daiken
58Servicing of ceiling suspended DX type AHU of VRF system by checking all parts, repair to electrical connection, cleaning of air filter, cooling coil, fan/blower and replacing minor u/s parts like bushes, nut bolts including taking down air diffuser grill from fall ceiling, cleaning and refixing of the same complete all as specified and directed.
59M&L for replacement of Unsv indoor unit of split type AC 1.5 TR complete having 3 star rating suitable for (R-407/410/32) gas complete all as specified and directed. Existing Make- Voltas/Blue Star/Hitachi/Daiken
60M&L for replacement of unsv MCB SP C series 20 A to 32 A m breaking cap 6kA complete all as specified and directed. Existing Make - L&T/Legrand/Hager/Siemens
61M&L for replacement of Metal plug 20A, 2Pin+SC complete all as specified and directed. Existing Make : L&T/Legrand/Hager/Siemens
62M&L for replacement of Metal socket 20A, 2 pin+SCcomplete all as specified and directed. Existing Make :L&T/Legrand/Hager/Siemens
63M&L for replacement of Unsv sheet metal enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole C series MCB 20 Amps, 240 volts complete all as specified and directed. Existing Make: L&T/Legrand/Hager/Havel"s
64M/L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor1100 V grade with colour code and one run of 4.0 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in& including casing & capping complete all as specified and directed. ( Note :Two runs of 4.0 Sqmm copper cable, one run ofearth wire of 4.0 Sqmm copper cable shall be measured & paid as one length).
65Servicing of air shower for 2 persons by checking all electrical connection, replacing u/s wire, lugs, washers, sensors, push button, cleaning filters, blower motor servicing, oiling, replacement of bearing of blower assembly, bush etc complete all as specified and directed.
66M&L for replacement of unsv Doormat magnetic switch of air shower complete all as specified and directed.
67M&L for replacement of unsv hydraulic Door closer assembly of air shower complete all as specified and directed.
68M&L for repair of Printed circuit board of air shower for 2 persons taking down and re-fixing of the same complete all as specified and directed.
69M&L for servicing, rewinding of stabilizer 4 KVA with copper winding as per existing gauge & turns including replacement of defective items compete all as specified and directed.
70M&L for servicing, rewinding of stabilizer 5 KVA with copper winding as per existing gauge & turns including replacement of defective items compete all as specified and directed.
71M&L for replacement of unsv condenser cooling coils of Split type AC up to 3 TR cap with new copper coil including taking out unsv condenser coil complete all as specified and directed.
72M&L for replacement of unsv motor of air curtain as per existing make and modelincluding replacement of bush, baring etc as reqd at site complete all as specified and directed.
73M&L for replacement of unsv drain flexible PVC pipe of split type AC complete all as specified and directed.
74M&L for replacment of unsv HEPA filters having 99.97% DN to 0.3 MIC of Airshower as per existing size complete all as specified and directed.
75M&L for replacment of emergency release switch of Air shower including making proper connections complete all as specified and directed.
76M&L for replacment of unsv pre filtersof Air shower flange type having efficiency 95% DN to 10 MIC as per existing size complete all as specified and directed.
77M&L for servicing of VRF system53 KW having 03 Nos outdoor unitsby checking all parts, repair to electrical connection, cleaning of air filter, cooling coil, fan/blower and replacing minor u/s parts like bushes, nut bolts etc complete all as specified and directed.
78M&L for replacment of unsv rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) two layer ISI marked hoisted and fixed in position all as specified in SSR Pt-I of capacity 1000 Ltrs complete all as specified and directed.
79M&L for replacment of condensor coil blower motor of water cooler 40 to 150 Ltr /refrgerator 190 to 385 Ltr capacityas per existing type & model complete all as specified and directed.
80M & L Attending emergent complaints i.e pertaining to Air conditioners any type, water cooler any type, Refrigerator any type including carrying out minor repairs including replacing necessary capacitors, thermostat,relays, PCB etc as required to make the system in order/ functionalcomplete all as specified and directed. Note :- Rate of spare parts shall be measured and paid separately under relevant items. Minor parts deemed to include in cost of item.
81M & L fortaking out existing insulation& replace with new insulation 24 kg/cu mt density & cover with glass wool of 50 mm thickness & 26 gauge Aluminium clading complete all as specified and directed.
82M&L for taking out existing& Supply installation , testing& commissioning ofof PN 1.6 , 3 way modulating valve 100 mm dia forAHU,s chilled water coil application complete with motor actuator, thermostat, voltage transformer, flanges, nuts-bolts, gaskets duy insulated with 50 mm thick TF Quality EPS & covered with 12 mm sand cement plasterincluding Copper Power & controle cable of suitabe sizecomplete all as specified and directed.
83M&L for replacement of microprosser controller Model - 33 TR Scroll V3A Type Delux, Range 16/4/2, Aux supply 15 V AC complete all as specified and directed. Existing Make : Softhard
84M&L for replacement ofMicroprocessor Model:VLRP single V4, Type Delux, Range 6/5/4, Aux supply 13 V AC, complete all as specified and directed. Existing Make : Softhard
85M&L for replacement ofMicroprocessor Model 44 TR Scroll V3A, type Delux, Range 17/5/2, Aux supply 15 V AC complete all as specified and directed. Existing Make : Softhard
86M&L for replacement ofMicroprocessor Model Screw single 100 TR, V3 Type Delux, Range 7/7/4 Aux supply 15 V AC complete all as specified and directed. Existing Make : Softhard
87M&L for replacement of microprosserModel - 33 TR Scroll V2A Type Delux, Range 16/4/2, Aux supply 15 V AC complete all as specified and directed. Existing Make : Softhard
88M&L for replacement of microprosserModel - 22 TR Scroll V2A Type Delux, Range 16/4/1, Aux supply 15 V AC complete all as specified and directed. Existing Make : Softhard
89M&L for replacement of microprosser controller Model - EC, Type M2VPD, Range 5-30A, Aux supply 230V AC, Special 5 Sec curve MPD complete all as specified and directed. Existing Make : Softhard
90M&L for replacement of microprosser controller Model-EC, Type MVPD, Range- 80-440 A, Aux supply -230V AC, Special -5 Second curve MPD complete all as specified and directed.Existing Make : Softhard
91M&L for replacement of microprosser controller Model-EC, Type MVPD, Range- 5-30A, Aux supply -230V AC, Special -5 Second curve MPD complete all as specified and directed. Existing Make : Softhard
92M&L for replacement of microprosser controller Model- µ-VPD (SPLIT) EC, Range-360v-500v ac (Normal 415AC) , Aux supply -230V AC,complete all as specified and directed. Existing Make : Softhard
93M&L for replacement of microprosser controller Model- m3 PD Type-µ-MPD, Range 5 to 30 AMPS Aux Supply 13 VAC, Special - 5 Sec, complete all as specified and directed. Existing Make : Softhard
94M&L for duct thermal insulation class O nitrile rubber based thermal insulation 19 mm thick with treated woven glass fibre covering of 0.18mm thick, density of 200+20 GSM, Tensile strength 275+-25 Kg/mm for exposed to sun application (green colour) including fixing with adhesive which is specifically formulated for duct insulation which shall be free from benzene and joints shall be fixed with glass cloth foil based tape with self adhesive ability to ensure 100% leak proof, including taking out existing unsv insulation material, cleaning the duct surface complete all as specified by OEM & directed by Engineer-in-Charge. Existing Make - Armacell/Vidoflex/Eurobatex.
95M&L for taking out carefully damaged ducting including all accessoriescomplete all as specified and directed.
96Supply assembly and erection of GI sheet with C &SS rectangular/square duct made out of L shaped hollow profile, duly factory boxed, incl all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size22 gaugeall as specified and including with required scaffolding work to install the ducts at site complete all as specified and directed. Note :-(i) for measurementonly the final finished area in Sqmm shall be measured. (ii) Venes, splitters, MS frames for joints, flanges, access doors etc shall not be measured seprately .These shall be treated as part of duct work. (iii) only external angle Iron/C channelduct support shall be measured and paid separatly.
97S&F in replacement of blower belt of AHU/Compressor belts as per existing model and type ISI marked including re-alignment of the motor and blower if required for proper tension of belts complete all as specified and directed.
98M&L for replacment of unsv centrifugal monoset pump set suitable for working on 415V three Phase 50 Hz AC supply having 2900 RPM, 5.5KW/7.5HP, discharge 14 LPS at 28 mtr head, del size 80x65mm, class B insulation,Existing Model No KD6-830Make- Kirloskar (2402 Sqn)complete all as specified and directed.
99S&FRotational mounted polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed including necessaryfittings required for inlet, outletwater pipeconnection(such asbarrel nipple, union, tee, drain plug, air vent pipe for outlet line etc.) complete all as specified and directed for following capacity :-
100(a) 2000 Ltr Cap
101(b) 5000 Ltr Cap
102Supply, installation, testing & commissioning of 100 mm dial type Pressure Gauge with appropriate range & SS valvesand SS tubing complete all as specified and directed.
103Supply, installation, testing & commissioning of set of 150 mm dial type Temp Gauge with appropriate range & SS valvesand SS U tubing complete all as specified and directed.
104M&L for replacement of old unsv outdoor unit of split typewith AC 3 star rating, 1.5 TR Cap having copper tubing, high EER rating compressor (for gas R-407/410/32), blower motor etc. complete including, making elect, refrigerant piping connection, brazing, leak testing and chargingsuitable refrigerant gasto achieve desired cooling effect and testing complete all as specified and directed. Existing Make- Blue Star/Voltas/Hitchin/Daiken
105M&L for replacement of Unsv indoor unit of split type AC 1.5 TR complete having 3 star rating suitable for (R-407/410/32) gas complete all as specified and directed. Existing Make- Voltas/Blue Star/Hitachi/Daiken
106Supply and lay and jointing tubing medium grade galvanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches complete all as specified and directed.of size :- (a) 25 mm bore
107S & F gun metal globe or gate valves with iron wheel headscrewedbothend for iron pipe and fixed complete all as specified and directed. (a) 25 mm dia bore
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail