Tender For Enhancement In External Electric Lt Works Including Allied Items At National War Memorial At New Delhi, New Delhi-Delhi

Military Engineer Services-MES has published Tender For Enhancement In External Electric Lt Works Including Allied Items At National War Memorial At New Delhi. Submission Date for this Tender is 20-12-2022. Cushioning Supplies Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35044048
Corrigendum : Tender For Enhancement In External Electric Lt Works Including Allied Items At National War Memorial At New Delhi
Open Tender
Indian
Delhi
New Delhi
20-12-2022

Tender Details

Tender For Enhancement In External Electric Lt Works Including Allied Items At National War Memorial At New Delhi - Supply And Lay Cable Xlpe Insulated Screened Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Poer Cables ( Heavy Duty ) 1100 Volt Grade With Stranded Aluminium Conductor Of Size 70 Sqmm 3.5 Core Complete All As Specified And Directed 2 Supply And Lay Cable Xlpe Insulated Screened Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Poer Cables ( Heavy Duty ) 1100 Volt Grade With Stranded Aluminium Conductor Of Size 50 Sqmm 3.5 Core Complete All As Specified And Directed 3 Supply And Lay Cable Xlpe Insulated Screened Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Poer Cables ( Heavy Duty ) 1100 Volt Grade With Stranded Aluminium Conductor Of Size 35 Sqmm 3.5 Core Complete All As Specified And Directed 4 Supply And Lay Cable Xlpe Insulated Screened Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Poer Cables ( Heavy Duty ) 1100 Volt Grade With Stranded Aluminium Conductor Of Size 4 Sqmm 3 Core Complete All As Specified And Directed. Note For Item No 1 To 6:-Rate Deemed To Be Inclusive Of Connecting Up With Control Gear Including Cable Glands And Cable Lugs. 5 Supply And Fixing Medium Grade Galvanised Iron Pipe 80 Mm Bore, And Isi Marked With All Fittings Fixedon Walls / Poles Crossing Of Roads Etc. For Protection Of Cable And For Protection Of Earth Strips Complete All As Specified And Directed. 6 Cutting Chases, Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Pcc Floor / Walls Etc., And Making Good, Cuttingexc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed. 7 Earthing Complete With Galvanised Steel Earth Plate Electrode 60×60Cm.× 6Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not LessThan 1.5 Metres Below Normal Ground Level, Connected To Galvanised Earth Lead Wire 4.0Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No. 3 Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completioncomplete All As Specified And As Directed. 8 Earthing Complete With Galvanised Steel Earth Plate Electrode 60×60Cm.× 6Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not LessThan 1.5 Metres Below Normal Ground Level, Connected Togalvanised Iron Strip 32×6 Mm As Earthing Leaddia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No. 3 Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completioncomplete All As Specified And As Directed. 9 Supplying, Installing, Testing And Commissioning Of Factory Made Lt Cubical Panel Board, 440 Volts, 50Hz, 3 Phase, 4 Wire, Outdoor Type, Weather, Vermin And Dust Proof, Front Operated With Adequate Air Ventilation At Sides And Back Fabricated Out Of 3.15Mm Thick Crca Sheet With Double Door Shutter And Locking Arrangements, Cable Trays, Cable Lugs Etc., Including Provision For Taking Out Incoming And Outgoing Cables Duly Marked With Revetted Letter Plates Of Appropriate Size For Each Feeder Cable, Danger Board Etc., Suitable To Accommodate And Including The Following Mentioned Fittings, Floor Mounted With Suitable Nut, Bolts, Washers Etc. For Grouting, All As Specified And Directed Comprising Of The Following:-And Inner Shell Shall Be Made Out Of 2 Mm Thick Crca Sheet Duly Compartmentalized For Each Control Gear Including Front And Back Openable Single Door With Fency Lockfor Each Compartmentwith Mc 100 Pedastal For Grouting In Floor Including Foundation For Panel Suitable For 3 Phase 415 Volts 50Hz Comprising Of ( A ) 300 Amps Aluminium Bus Bar For Phases And 150Amps For Neutral Duly Insulated With Pvc Sleeves Ryb, Mounted On Heavy Duty Epoxy Insulation In Separate Compartment.-01 Set. ( B ) Mccb Of Capacity 4 Pole 160 Amps 25 Ka-01 No ( Incoming ) . ( C ) Mccb Fp 63Amps10ka -01 Nos ( For Outgoing ) . ( D ) Mcb Fp 40A 10 Ka -02 N0s, ( E ) Mcb 40 Amp Dp, 10 Ka-03 Nos, ( F ) Mcb 16 Amp Dp, 10 Ka-06 Nos, ( G ) 16 Amp S / S Combination-03 Nos ( H ) Digital Multi Function Meter ( Volt Meter 0-500V, Ammeter 0-300A, Frequency Meter & Power Factor Meter ) Of Size 96Mmx96mm With Programmable Ct Ratio With Back Up Protection By 2 A Mcb Sp. ( J ) Cts 400 / 5 Amps - Set Of Three ( G ) Indicating Lamp 240 Volts Led Type - Set Of Three ( H ) Internal All Links & Control Cable And Inspection Lamp -01 ( J ) Cts 200 / 5 Amps - Set Of Three Complete All As Specified And As Directed By Engr-In-Charge 10 Supplying, Installing, Testing And Commissioning Of Factory Made Lt Cubical Panel Board, 440 Volts, 50Hz, 3 Phase, 4 Wire, Outdoor Type, Weather, Vermin And Dust Proof, Front Operated With Adequate Air Ventilation At Sides And Back Fabricated Out Of 3.15Mm Thick Crca Sheet With Double Door Shutter And Locking Arrangements, Cable Trays, Cable Lugs Etc., Including Provision For Taking Out Incoming And Outgoing Cables Duly Marked With Revetted Letter Plates Of Appropriate Size For Each Feeder Cable, Danger Board Etc., Suitable To Accommodate And Including The Following Mentioned Fittings, Floor Mounted With Suitable Nut, Bolts, Washers Etc. For Grouting, All As Specified And Directed Comprising Of The Following:-And Inner Shell Shall Be Made Out Of 2 Mm Thick Crca Sheet Duly Compartmentalized For Each Control Gear Including Front And Back Openable Single Door With Fency Lock ( 02 Nos For Each Compartment ) With Mc 100 Pedastal For Grouting In Floor Including Foundation Suitable For 3 Phase 415 Volts 50Hz Comprising Of ( A ) 300 Amps Aluminium Bus Bar For Phases And 150Amps For Neutral Duly Insulated With Pvc Sleeves Ryb, Mounted On Heavy Duty Epoxy Insulation In Separate Compartment.-01 Set. ( B ) Mccb Of Capacity 4 Pole 63 Amps 25 Ka-01 No ( Incoming ) . ( C ) Mccb Fp 40 Amps10ka -01 Nos ( For Outgoing ) . ( D ) Mcb Dp 20A 10 Ka -02 N0s, ( E ) Mcb 10 Amp Dp, 10 Ka-03 Nos, ( G ) 16 Amp S / S Combination-03 Nos ( H ) Digital Multi Function Meter ( Volt Meter 0-500V, Ammeter 0-300A, Frequency Meter & Power Factor Meter ) Of Size 96Mmx96mm With Programmable Ct Ratio With Back Up Protection By 2 A Mcb Sp. ( J ) Cts 400 / 5 Amps - Set Of Three ( G ) Indicating Lamp 240 Volts Led Type - Set Of Three ( H ) Internal All Links & Control Cable And Inspection Lamp -01 ( J ) Cts 200 / 5 Amps - Set Of Three Complete All As Specified And Directed By Engr-In Charge. 11 Excavation In Trenches In Soft / Loose Soil Not Exceeding 1.5 Mtr Deep And Getting Out Including Dressing / Triming Sides And Levelling / Grading And Ramming Of Bottoms Of Excavation The Sit For All Leads And Lifts Complete All As Specified And As Directed By Engineer-In-Charge. 12 Returning Filling In Soil ( Of Any Type ) Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25Cm Thick Complete All As Specified And As Directed By Engineer-In-Charge. 13 Removing Excavated Material N Exc 50M And Depositing Where Directed At A Level N Exc 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material & Labour For Boring Of Holes Under Road Pavement, Hard Standing By Trenchless Technology Including Hdpe Pipe Of 100 Mm Dia, Complete All As Specified And As Directed By Engineer-In-Charge. 15 Supply And Spreading River Sand In Trenches As Cushioning To Under Ground Cable On Top And Bottom Of Cable All As Specified. 16 Supplying And Laying Reinforced Precast Concrete Cable Cover, Class Lv, Type 1With Peak, Size 250Mm X 150Mm X 40Mm

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 22960.0 /-
Tender Value
INR 11.48 Lakhs /-