Tender For Kiifb- Registration Department - Construction Of New Sub Registraroffice At Parappanangadi In Malappuram District
Tender Value
1.66 Crore
Estimated cost
Bid Submission
09 Dec 2022
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Kiifb- Registration Department - Construction Of New Sub Registraroffice At Parappanangadi In Malappuram District
BOQ
| Sl. No. | Item Description |
| 1 | Appendix -1General Civil Work2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 2 | 2.26.1 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil |
| 3 | OD45457/2021-2022 Providing anti termite treatment by using chemical concentration as per IS 6313 (part 11) 1981.The chemical is dissolved in water at the rate 1lit/20lit. The treatment is given as pre-constructional anti- termite treatment using chemical emulsion at 5 to 7.5 litres per squire metersand creating a chemical barrier under the column pits wall trenches, basements excavation and plinth area etc. The works are to be guarenteed for a minimum of ten years. |
| 4 | OD43427/2021-2022Dry rubble masonry with hard stone in foundation including leveling up with CC1:6:12 including cost of through and bond stone |
| 5 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement:4coarse sand : 8 graded stone aggregate 40 nominal size) |
| 6 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 7 | 5.33.1Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying butexcluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level |
| 8 | 5.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost ofcentering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). |
| 9 | 5.33.2Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level |
| 10 | 4.1.3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 11 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 12 | 5.92Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc |
| 13 | 5.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 14 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 15 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 16 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 17 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 18 | 50.6.2.1 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cmor nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete |
| 19 | 50.6.2.2Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 20 | 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 21 | 13.7.1 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1cement : 3 fine sand) |
| 22 | OD45466/2021-2022 Plastering with cement mortar 1:3, 12mm thick adding water proofing compound 1kg/50kg of cement with neat cement flushing coat to lines and levels including thread lining etc. complete as per the direction of Departmental officers at site for terrace slab and top of sunshade |
| 23 | 50.13.1 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete |
| 24 | 5.30 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. |
| 25 | 11.20.1Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement |
| 26 | 11.36Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 27 | 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the jointswith white cement and matching pigments etc., complete |
| 28 | 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 29 | OD45474/2021-2022Providing filter media in tank already fixed including charges for conveying liftingand filling etc complete. |
| 30 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 31 | OD45506/2021-2022 Door with frame made out of section 105x60mm for outer frame and 75x30mmforshutters using 18G Galvano steel sheets and inner sheet using 20G Galvanosheet welded and assembled with M.S butt hinges 125mm - 4nos/side and fitted withstainless steel fittings like Aldrop,Towerbolts, and Handles fitted with stainless steel fittings like Aldrop,Towerbolts, and Handles andfinaly coated with zincromate yellow primer to size including all labour charges for fixing etc. complete ( single shutters |
| 32 | OD45513/2021-2022Door with frame made out of section 105x60mm for outer frame and 75x30mmforshutters using 18G Galvano steel sheets and inner sheet using 20G Galvanosheet welded and assembled with M.S butt hinges 125mm - 4nos/side and fitted withstainless steel fittings like Aldrop,Towerbolts, and Handles fitted with stainless steel fittings like Aldrop,Towerbolts, and Handles andfinaly coated with zincromate yellow primer to size including all labour charges for fixing etc. complete ( Double shutters |
| 33 | 9.48.2 Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 34 | 21.1.1.2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 35 | 21.3.1Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness |
| 36 | 21.1.2.2For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for eparately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 37 | 9.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in Charge. |
| 38 | 9.120.1Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. framewelded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive.An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. complete as per direction ofEngineer -in-charge, manufacture\"s specification & drawing.30 mm thick plain PVC door shutters |
| 39 | 13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 40 | 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 41 | OD45568/2021-2022 Painting outer walls two coats with anti fungal weather proof exterior paint of approved quality and colour as directed by departmental officers at site. |
| 42 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 43 | OD45574/2021-2022Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 44 | 10.2Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 45 | 12.51.6 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%)total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpasteel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth) |
| 46 | OD45576/2021-2022 Supplying Anodised aluminium hanging type door stopper |
| 47 | 9.84 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 48 | 17.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mmSand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 49 | 17.3.1 Providing and fixing white vitreous china pedestal type water closet (European type)with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement withspecials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good thewalls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 50 | 17.7.3 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 51 | 50.18.9.14.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mmdia 6 Kgf/cm2 - External work - Exposed on wall |
| 52 | 50.18.9.8.2 Providing and fixing PVC pipes includings of pipes with one step PVC solventcement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2 |
| 53 | 50.17.1.1Supplying and fixing Stainless steel soap dish including cost of materials and labourcharges etc complete as per the direction of site Engineer-in-charge |
| 54 | 50.17.1.3Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-incharge. |
| 55 | 50.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 56 | 50.18.9.9.2Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineerin CHarge. 110 mm dia 4 Kg/cm2 |
| 57 | 50.18.9.19.2Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 mspacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 -External work - Exposed on wal |
| 58 | 50.18.9.22.1 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow |
| 59 | 50.18.9.22.2 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 60 | 50.18.9.22.3 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 61 | 50.18.9.22.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend |
| 62 | 50.18.9.21.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement - 75 mm dia Bend |
| 63 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 64 | 50.18.9.21Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow |
| 65 | 50.18.9.21.3Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow |
| 66 | 50.18.9.22.6 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 67 | 50.18.9.22.8Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 68 | 50.18.9.21.5 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee |
| 69 | 50.18.9.21.6 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee |
| 70 | 50.18.9.21.7 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 71 | 50.18.9.22.9Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia offset |
| 72 | 18.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 73 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 74 | OD45579/2021-2022Supplying and Fixing PVC floor trap best quality |
| 75 | OD45580/2021-2022Supplying and filling the soak pit with soling stones of sizes from 80 mm to 100 mmsize including cost, conveyance, all leads and lifts etc complete. |
| 76 | 13.28.312 mm thick plain cement mortar bands in cement mortar 1:4 ( 1 cement : 4 fine sand) :Raised Band |
| 77 | 13.71 Lettering with black Japan pint of approved brand and manufacture |
| 78 | Appendix -2 EXTR ITEMS :- 20.2.4Boring, providing and installing bored cast-in-situ reinforced cement concrete piles ofgrade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution and temporary casing ofappropriate length for setting out and removal of same and the length of the pile to beembedded in the pile cap etc. all complete, including removal of excavated earth withall lifts and leads (Length of pile for payment shall be measured upto bottom of pilecap).500 mm dia piles |
| 79 | 20.6.1.2Vertical load testing of piles in accordance with IS 2911( Part IV) includinginstallation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & thedirection of engineer -in-Charge. Single pile upto 50 tonne capacityRoutine test |
| 80 | 50.2.25.1 Filling with contractor\"s own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 81 | 50.2.26.1Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming andwatering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-incharge |
| 82 | 50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 83 | OD46844/2021-2022Providing and fixing 8 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 84 | 26.19.1 Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS2676. The sheet shall be fixed using self drilling/self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, verticalor curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. butxcluding the cost of purlins, rafters and trusses.0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm |
| 85 | 50.18.9.4.1Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2 |
| 86 | 50.18.9.14.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mmdia 10 Kgf/cm2 - External work- Exposed on wall |
| 87 | 50.18.9.6.2Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2 |
| 88 | 50.18.9.16.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall |
| 89 | 50.18.9.3. 2Providing and fixing PVC pipes includes jointing of pipes with one step PVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineerin Charge. 25 mm dia 10KGF/cm2 |
| 90 | 50.18.9.13.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mmdia 10 Kgf/cm2- External work - Exposed on wall |
| 91 | 50.18.8.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe10kgf /cm2 |
| 92 | 50.18.9.7.2 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2 |
| 93 | 50.18.9.20.2Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow |
| 94 | 50.18.9.20.3 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow |
| 95 | 50.18.9.20.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend |
| 96 | 50.18.9.20.5 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee |
| 97 | 50.18.9.20.6Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63x63x63 mm dia Door Tee |
| 98 | 50.18.9.20.7 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia vent cowl |
| 99 | 50.18.9.21.2Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement -75 mm dia 45 degree Elbow |
| 100 | 50.18.9.21.10 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -75x63 mm dia Reducer |
| 101 | 18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 102 | OD48538/2021-2022 Supplying and fixing SS gratings(15CMX15CM) in toilets |
| 103 | OD48551/2021-2022Providing and fixing CI Man hole cover of Size 455x610 with frame |
| 104 | OD48895/2021-2022 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 50mm BALL VALVE |
| 105 | OD48899/2021-2022 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm Y |
| 106 | OD48900/2021-2022Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110MM BALL VALVE |
| 107 | OD48903/2021-2022Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 32mm PVC VALVE |
| 108 | OD48914/2021-2022 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 25mm PVC VALVE |
| 109 | OD48917/2021-2022 Supplying Godrej NAVTAL Brass pad lock 65mm with four keys |
| 110 | 50.18.9.5.1Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2 |
| 111 | Appendix -3 OPEN WELL:-2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 112 | 2.26.1 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil |
| 113 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 114 | 5.4 Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size) |
| 115 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 116 | 50.6.7.1Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc |
| 117 | 50.13.1 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete |
| 118 | 7.1.1Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 119 | Appendix -3 Electrification:-OD60779/2021-2022Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point |
| 120 | OD60788/2021-2022 Supply and wiring points according to IS 732-1989 using rigid PVC medium conduitof minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Twin Control light point with 6A, plate ceiling rose - Short point |
| 121 | OD60789/2021-2022 Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single corecopper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single control light point without ceiling rose - Short point |
| 122 | OD60790/2021-2022 Supply and wiring points according to IS 732-1989 using rigid PVC medium conduitof minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point |
| 123 | OD60780/2021-2022 Supply and wiring points according to IS 732-1989 using rigid medium gauge PVCconduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing theconduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and thewires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point |
| 124 | OD60781/2021-2022 Supply and wiring points according to IS 732-1989 using rigid PVC medium conduitof minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single corecopper conductor cable 650V grade, including providing switch board main andcontinuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc.complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points |
| 125 | OD60782/2021-2022 Supply and wiring points according to IS 732-1989 using rigid PVC medium gaugeconduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,cutting the walls, fixing theconduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.5 sqmm green coloured FRLS PVC insulated stranded,single core copper conductor ,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switchboxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc asrequired. (RoHS compliant modular accessories). Independent plug - Short point |
| 126 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 127 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 128 | 1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 129 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 130 | 1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 131 | 1.27.5Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 132 | 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 133 | 1.17.6Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x1.5 sq. mm |
| 134 | 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 135 | 1.17.30 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 136 | 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 137 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 138 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 139 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 140 | 1.24.6 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 141 | 1.24.7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 142 | 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 143 | 1.22.1Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75 mm X 75 mm X 60 mm deep |
| 144 | 90.5.1.3 Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell |
| 145 | 90.3.20.3 Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings offollowing types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections asrequired.1200 mm 1X20W LED Lamp with box type fixture |
| 146 | 90.3.21.3 Supply & installation of light fittings on \"C/U\" shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. \"C/U\" brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture |
| 147 | OD60878/2021-2022Supply and fixing low glare high efficiency square surface mounted LED flat panel230V 50Hz 36 w light fitting complete with all required accessories etc. as required |
| 148 | 90.3.18.2 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 149 | 90.15.4.1 Supply Conveyance, installation, testing and commissioning of 20W LED street lightoutput greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surgeprotection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHScompliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABLccredited Third party lab to be produced mentioning chip manufacturer) |
| 150 | OD60880/2021-2022Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W LED light to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required |
| 151 | OD60881/2021-2022Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with aluminium shade, 9W LED bulb and giving connection etc as required |
| 152 | 90.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as perIS 732 as required |
| 153 | 90.4.5.2 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3core round copper conductor flex wire or with extended original wiring etc. as required. Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiringthe down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C |
| 154 | 90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. |
| 155 | OD60883/2021-2022 Supply, conveyance, installation, testing and commissioning of 225mm light duty exhaust fan in metal frame in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with requiredlength of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. |
| 156 | 90.9.2.1 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid5 |
| 157 | 90.9.2.2 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider |
| 158 | 90.9.2.3Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree |
| 159 | 90.9.2.4 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree |
| 160 | 90.9.2.5 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.Internal angle 90 degree |
| 161 | 90.9.2.7Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.Flat cross |
| 162 | 90.9.2.8Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation asrequired.End cap |
| 163 | 90.9.2.10 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.Joint cover |
| 164 | 90.9.2.11 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.Cable retainer |
| 165 | 90.9.2.12Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.1 to 3 module mounting box |
| 166 | 90.9.2.13Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.4 to 5 module mounting box |
| 167 | OD60884/2021-2022 Supply, testing and installation of Jack Cat6 Keystone UTP with Collapsible Shutter- White Make - D Link NKJ-C6WHI1B21 |
| 168 | OD60885/2021-2022Supply, testing and installation of Face Plate-Single(Keystone jack,square) Make - D Link NFP-OWHI11 |
| 169 | OD60886/2021-2022 Supply, testing and installation of Back Box Make - D Link NBB-011 |
| 170 | 1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 171 | 90.11.1.14Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchorbolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 172 | 90.11.1.15 Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchorbolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 173 | 2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCBIRCCB/Isolator12 way, Double door |
| 174 | 2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 175 | 2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 176 | 2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc.as required |
| 177 | 2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 178 | 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 179 | 2.14.1Supplying and fixing following rating, double pole, (single phase and neutral), 240volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 180 | 2.15.1Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 181 | 2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 182 | 2.16Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 183 | 90.12.7.40 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages ,colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 184 | 90.12.7.41 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages ,colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 185 | 9.1.32Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 10 sq. mm (25mm) |
| 186 | 9.1.33Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 16 sq. mm (28mm) |
| 187 | 90.12.24.4 Supply of superior quality copper tubular cable socket and making core termination ofcables of the following sizes including crimping etc. as required.10 sq mm |
| 188 | 90.12.24.5Supply of superior quality copper tubular cable socket and making core termination ofcables of the following sizes including crimping etc. as required.16 sq mm |
| 189 | OD60888/2021-2022 Supplying and providing earth clamps for siemens/ tripodular type cable glands ofsuitable length and other dimensions noted along with each size of glands for 4sqmm - 16 sq mm sizes of cables with 12 mm wide x 1 mm thick clip as required |
| 190 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 191 | 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 192 | OD60889/2021-2022Supply and providing test joint for the earthing system using 2 Nos of 2x25x3mm of GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. |
| 193 | OD60890/2021-2022 Supply and providing 25 x 3 mm GI strip earth lead from the test joint to the earthelectrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. |
| 194 | OD60891/2021-2022 Supply and laying bare earthing conductors of size3.15 mm copper conductor (10SWG) laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil). |
| 195 | OD60892/2021-2022Supply and providing 25 x 6 mm brass bolt & nut with washers on the existing MSbox / earth bus etc. as required including drilling necessary holes as required |
| 196 | OD60893/2021-2022Supply and providing 25 x 3 mm brass bolt & nut with washers on the existing MSbox / earth bus etc. as required including drilling necessary holes as required |
| 197 | OD60894/2021-2022 Supply and providing 12 x 3 mm brass bolt & nut with washers on the existing MSbox / earth bus etc. as required including drilling necessary holes as required |
| 198 | 90.16.2.2 Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class) |
| 199 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 200 | 2.1.2Providing and fixing following capacity TP&N disconnector fuse switch unit insidethe existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N |
| 201 | OD60895/2021-2022 Supply, testing and installation of 1 phase 1 HP submersible open well pump & motorwith head range 20-40 mtrs having maximum flow rate of 90 LPH at 25 Mtrs and necessary accesories excluding pipe and extra length of wire (make Texmo/Crompton/Kirloskar/CRI) |
| 202 | 90.6.6.2Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copperconductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm |
| 203 | OD60896/2021-2022Supply, testing and installation of single phase 1/2 HP mono block open well pump (CRI / Texmo) |
| 204 | OD60898/2021-2022 63 A, 415 V, DIN type fuse base |
| 205 | OD60899/2021-2022 Supply and fixing 63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base |
| 206 | OD60900/2021-2022 Supply and fixing 2 -80A, DIN type fuse link of size in the existing meter board and giving connections etc. |
| 207 | OD60901/2021-2022Supply and Installation / Fixing / Provision of Outdoor type HENSEL make(600X300x214 mm Mi 2410) suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with completetamper proof SEALING facility |
| 208 | OD60904/2021-2022Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint \"FIRE\" mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required |
| 209 | OD60905/2021-2022Supply & providing First Aid Chart duly framed and placed ina conspcious locationfor clear vision |
| 210 | OD60902/2021-2022 Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required |
| 211 | OD60903/2021-2022Painting letters or figures of size 2.50 cm, 4 cm or 5 cm height with enamel paint as identification mark to SB, DB, panel board etc as required |
| 212 | OD71820/2021-2022 Supply, installation, testing and commissioning of Dumb Waiter 100 kgs capacity withthe following specifications: 1. Speed - 0.25m/second 2. Type of drive - Single speed 3. Machine motor unit - 3 phase induction motor 415V 4. Location of machine room -Above lift well 5. Travel - Apprx. 4 metre 6. Serving - 2 floors, 2 opening 7. Power supply - 415V 3 phase 50 hz AC 8. Car enclosure : SS hairline finish 9. Car size -700mm W x 700mm D x 800mm H 10. Flooring - Anti skid PVC flooring 11. Carentrance - Vertical Bi parting door SS 700 mm x 800 mm 12. Landing entrance - Vertical Bi parting door SS 700 mm x 800 mm 13. Type of controller - MicroProcessor Down Collective 14. Special features : Stainless steel face plate for landing, Push button and floor position indicators for landings Machine Components Worm gear consisting of worm wheel of centrifugally cast bronze and worm of speciallyforged steel. Worm wheel to be coupled to specially designed motor suitable for elevator duty. Arrangement for releasing the brake manually and bringing the car to the nearest floor by a hand wheel/fly wheel to be provided. Structural steel ca frame to support the car platform and enclosure to be provided with suitable safety grar fixed underneath the frame. Control board with enclosure to be installed in the machine room. Automatic door operation consisting of a motor operated device on elevator car for smooth and quiet opening and closing of can and landing doors simultaneously to be provided. A fixed cam to be provided on top of elevator. Guide rails to be of achined ground steel T - section withsuitable fixing arrangement and counter weight of structural steel frame loaded with appropriate filler wrights to be provided. Steel wire ropes for suspension to be provided. Special steel/ oil buffers to be provided asper standard design. Electro mechanical locks to be provided for each landing doors and should have mechanical interlocking with built in electric contacts. Electric cable/ wiring to be provided as per design and car name plate to be fitted on car indicating elevator capacity. |
| 213 | OD71821/2021-2022 Supply and installation of High Pressure Water Mist and CAF Fire extinguisher back pack 9L capacity with Fire rating of 55A, 233B, 1000V with Special AFFF Compound with Pressure Vessel and Cylinder made of Ultralight Carbon composite material , Fire rating 55A, 233B , 1000V with one spare compressed Air Cylinder 2 Litre x 300 bar (Ultralight carbon composite with PET Liner), 10 Nos. O-rings for pressure vessel,one can 5 Litre special AFFF compound and one tool kit. Total weight 20kg and nozzle weight 75 0 grams.SPECIFICATIONSGENERIC1.Conformity to EN 3- 2004+A1:2007-08 standards The complete system shall be tested for compliance from an internationally/nationally accredited laboratory for compliance to all 29 clauses (3.2, 3.15, 4.2, 4.3, 4.4, 4.5, 6.1, 6.2, 6.3, 7.1.1, 7.1.2, 7.2, 7.3, 7.4, 8.1, 8.2, 9.2, 10.1, 10.2, 10.4, 10.5, 10.6.1 & 10.6.2, 14.1, 14.2, 15.2, 15.3, 16.1, 16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily appli cable for the complete ystem.2.Mounting Type: Backpack3.Configuration : Shall be mounted on a sturdyframe suitably cushioned for comfort, provided with shoulder pads for carrying as a backpack and a handle to be carried by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders.4.Main Components: Pressure vessel to hold the media with safety valve, compressed air cylinder coupledwith a reducer, hose pipes for discharge of water mist media, extinguishinggun.Constructional1.Air Cylinder Material should be Ultralight Carbon composite with PET Liner2.Type of Foam should be Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55, B233, Spreadingcoefficient for special AFFF Compound shall be +5 minimum, concentration shall be 6%.3.Commercial Brand Name of the Special foam (fire extinguishing medium) as per accredited laboratory test report wherein higher fire ratings i.e A55,B233, E1000 V(Die Electric Suitability) achieved, to be declared in the single Test Report of complete system.4.Characteristics of extinguishing medium of Special AFFF Compound (manufacturer own specifications) with infrared spectrogram to be furnished like Density, Viscosity, pH factor, Refractive index at 20 ± 2degC.5.Pressure Vessel Material & Capacity (Nominal Charge) should be Ultralite Carbon Composite with PET Liner of 9 liter capacity to be drawn by accredited test report.6.Extinguishing gun material should be stainless steel7.Extinguishing gun weight should 750 grams approx.8.Length of EN marked Hose should be 1.3 meter forbackpack system9.Weight of fully charged Backpack system below 20 kg having Ultralite Carbon Composite with PET Liner Vessel.PERFORMANCE1.Air Cylinde r Capacity (Ltrs) should be 2 Liters2.Air Cylinder pressure (Bar) 300 bar3.High Pressure Type Dynamic Operating pressure to be tested in the accredited laboratorytest report which will be considered as high pressure as per clause No. 3.15 of EN 3 - 7:2004 + Al: 2007-08 (E) Standard. > = 35 for Ultralite Carbon Composite with PET Liner vessel4.Lancing Distance of Gun: should be 12 meter approx.5.The air hosesshall be suitable for minus 40 deg C to 100 Deg C temperature and EN mark onhose6.Minimum operating time in full throttle for Ultralight Carbon composite with PET Liner vessel should be 29 seconds7.System shall be designed for maximum operating temperature TS max and minimum operating temperature TS min of 60 deg C or more and 5 Deg C or less respectively and certified by the manufactureraccordingly as per Clause 7.4 of EN 3-7:2004+A1:2007-08 standards as per theaccredited test report for backpack system.8.Fire Rating: 55A, 233B, 1000V withSpecial AFFF Compound as per manufacturer own specifications with commercialbrand name of fire exting uishing medium as per accredited laboratory test report for BackpackstemCERTIFICATION 1.PED approval as per Directive 97/23/ECshould be available.2.Pressure Vessel shall include a pressure gauge fitted on the Pressure Reducer (CE Marked from notified body) to measure the air cylinderpressure.3.\"No objection certificate (NOC) for Pressure Vessel from Petroleum andVessel should have CE Marking from Notified body5.The air cylinders shall havePESO, Nagpur approval to be used with Water Mist Fire Fighting System6.Specific consent of the OEM for the value additions made along with a confirmation that fire ratings of the equipment would not be affected by these value additions.7.Test Report to EN Standard as per above serial number 1 of Generic should be submitted. |
| 214 | OD64981/2021-2022Payment to KSEB Ltd. for three phase power connection |
AI Tender Summary
Tender Timeline
Nov 29, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedDec 09, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 14, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender