Public Administrative Department Local Bodies Closing in 0 days TDR #35037037

Tender For Supply And Installation And Maintenance Of Ocems I.E Ph, Bod, Cod, Tss And Flow

Issued by Local Bodies · Chittorgarh, Rajasthan
Tender Value
22 Lakhs
Estimated cost
Bid Submission
08 Dec 2022
0 days left
EMD
44000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chittorgarh → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply And Installation And Maintenance Of Ocems I.E Ph, Bod, Cod, Tss And Flow Along With 5 Year Comprehensive Operation And Maintenance As Well As Data Trasnger To Cpcb And Rspcb Server For Running 1.5Mld Stp At Near Kali Mangri Roadbarisadri Outlet , Supply , Installation, Testing & Commissioningof On Line Bod / Cod / Tss / Ph / Flow Meter In-Situ Based Analyzer As Percpcb Guideline For Online Continuous Effluentmonitoringsystem ( Ocems ) July 2018 With Panel For S.T.P. Effluent Measurement Items Uv-Vis Spectrometry Double Beam With Entire Spectrum Scanning 200 -720 Mm 190- 750Mm Wave Lengths Along With 256 Unique Pixel Diode. Make-Tethys / Xylem / Real Tech / Hach / Abb As Approved By Engineering In Charge ( All The Materials / Equipment And Apparatus Shall Be Got Approved By The Engineer In Charge Before Procurement Of The Items And There After Use In The Work. • Moc Of Bod / Cod / Tss Sensor -Titanium 3.7 F Ss316l Better • Cleaning Facility-Ultrasonic Cleaning Or Air Pressure Cleaning • Accuracy Of Bod / Cod / Tss Sensor-+ / -3% Of The Measured Value Light Source: Xenon Flash Lamp Or Following Measuring Ranges Are Required: Cod: 0-700 Mg / Ibod 0-400 Mg / 1 Tss: 0-600 Mg / 1 Ph Range 0 14 • Moc Of Ph. Sensor-Stainless Steel 316 Or Better Ph Accuracy + / 0.2% Protection Type: Ip 68 For Both The Sensor And Cable ( Cable ) Lengths Per Site Requirement ) Controller / Display- Housing Material Non Corrosive E.G. Acryl Onitrile-Styrene Acryl Ester Polymer Or Better • Protection Rating Ip 67 Controller / Display Cabin Box Should Be Ip66 Grade With Lock & Key Ss304 Grade Moc • Data Logger ( Including Data Transmission To Cpcb And Rspcb ) , Internet For Data Transmission Is In Bidders’ Scope. The Communication To The System Should Be Two Way The Data Should Be Received At Central Location And Should Be Displayed There In Real-Time In Graphical And Tabular Format. Operating Temperature 0 To 55 °C. Protection Surge Protection On Sensor Inputs, Over Voltage And Reverse Polarity Protection On Power Input. Storage 256Mb ( Industrial Microsd ) . Interface ( S ) 2 X Eia Rs485, 1 X R$232. 8 X 4-20Ma ( 1% Fs ) Usb Host 1 ( Usb 2.0 ) Voltage 9-24 Vdc 10% ( Nominal 12Vdc ) Power Sw ( Peak ) • Statistical Data Analysis ( Customizable ) For Average, Min... Max., Diurnal Variation. Auto Report To The System Should Be Two Way. The Data Should Be Received At A Central Location And Should Be Displayed There In Real-Time In Graphical And Tabular Format... Operating Temperature 0 To 55 °C. Protection Surge Protection On Sensor Inputs, Over Voltage And Reverse. Polarity Protection On Power Input. Storage 256Mb ( Industrial Microsd ) Interface ( S ) 2X Eia Rs485, 1 X Rs232, 8 X 4-20Ma ( 21% Fs ) Usb Host 1 ( Usb 2.0 ) Voltage 9-24 Vdc 10% ( Nominal 12Vdc ) Power 5W ( Peak ) • Statistical Data Analysis ( Customizable ) For Average, Min., Max, Diurnal Variation. Auto Report And, Auto Mail Generation Etc. • Comparison Of Parameters Of Different Locations In User Selectable Time Formats I.E. In Graphical And Tabular Formats Compatible To Ms. Excel, Ms Word, Txt Etc. Including Mandatory Fee For Data Transmission To Cpcb, Rspcb & Mcc Server ( Whenever Payable ) . • Ultrasonic Open Channel Flow Meter With Shall Comprise Of Flow Sensor / Transducer, Flow Transmitter, Digital Level Indicator / Remote Indicator. Control Unit • Operating Temperature: 0 To 50°C. Safety: Explosion Proof Or Intrinsically Safe. • Measuring Principal: Ultrasonic. •Communication Protocol: Open Protocol Like Modbus, Profibus, Hart, Etc. Analog Output: Isolated 4-20Ma, • Relay Contacts: Minimum Of 3 Spdt Contacts. •Accuracy: ± 0.25% Of Measured Value Or Better. •Output. 4-20 Ma • Protection A. ) Sensor: Ip-68. B. ) Transmitter / Controller: Ip-66 ( Nema 4X ) . •Display: Lcd With Led Backlighting 130 , 1 Kva Ups • Capacity -1000Va / 600W • Input Voltage Range 140 V 300 V Ac Frequency 50 Hz ± 10% •Operating Temperature 0°C-40°C; •Charging Time 6-8 Hours Recover To 90% Capacity Battery Rating Smf 12V / 7Ahx2 Batteries, •Output Voltage 230 V Ac Nominal Transfer Time Typical 4-8Ms • Type Sealed Maintenance Free , Comprehensive Operation & Maintenance Cost For Whole System For 2Nd Year Including Data Transmission To Cpcb, Rspcb & Mcc Website, Four Service Visits, Two Times Calibration Of System In A Year, Repairable Cost, Replacement Cost. Consumables Etc. , Comprehensive Operation B Maintenance Cost For Whole System For 3Th Year Including Data Transmission To Cpcb, Rspcb & Mcc Website, Four Service Visits, Two Times Calibration Of System In A Year. Repairable Cost, Replacement Cost, Consumables Etc. , Comprehensive Operation & Maintenance Cost For Whole System: For 4Th Year Including Data Transmission To Cpcb, Rspcb & Mcc Website, Four Service Visits, Two Times Calibration Of System In A Year. Repairable Cost, Replacement Cast, Consumables Etc. , Comprehensive Operation & Maintenance Cost For Whole System For 5 Year Including Data Transmission To Cpcb, Rspcb & Mcc Website, Four Service Visits, Two Times Calibration Of System In A Year, Repairable Cost, Replacement Cost, Consumables Etc.

BOQ

????? ?? ???:- Supply, installation and maintenance of online continuous Effluent monitoring System (OCEMS) I.e. pH, BOD, COD, TSS & FLOW along with 5-year Comprehensive operation and maintenance as well as data transfer to CPCB & RSPCB server for running 1.5 MLD STP at Near Kali Mangri Road Badi Sadari Outlet.
Sl. No. Item Description
1Supply , Installation, TESTING & Commissioningof On Line BOD/COD/TSS/PH/FLOW Meter in-situ based Analyzer AS PERCPCB Guideline for Online Continuous EffluentMonitoringSystem ( OCEMS) JULY 2018 with panel for S.T.P. effluent Measurement items UV-VIS Spectrometry Double beam with entire spectrum scanning 200 -720 mm 190- 750mm wave lengths along with 256 unique pixel diode. Make-Tethys/xylem/Real tech/Hach/ABB as approved by Engineering in charge (All the materials/equipment and apparatus shall be got approved by the Engineer in charge before procurement of the items and there after use in the work.• MOC of BOD/COD/TSS sensor -Titanium 3.7 f SS316L better • Cleaning facility-ultrasonic cleaning or Air pressure Cleaning• Accuracy of BOD/COD/TSS sensor-+/-3% of the measured value Light Source: Xenon Flash Lamp orFollowing measuring ranges are required: COD: 0-700 mg/IBOD 0-400 mg/1 TSS: 0-600 mg/1 Ph range 0 14 • MOC of ph. sensor-Stainless Steel 316 or better Ph Accuracy +/ 0.2% protection type: IP 68 for both the Sensor and Cable (Cable) lengths per site requirement) Controller/Display- Housing Material Non corrosive e.g. Acryl onitrile-Styrene Acryl ester polymer or better • Protection Rating IP 67 Controller/display cabin box should be IP66 Grade with lock & Key SS304 Grade MOC• Data Logger (including Data transmission to CPCB and RSPCB), Internet for DATA transmission is in bidders’ scope. The communication to the system should be two way the data should be received at central location and should be displayed there in real-time in graphical and tabular format. Operating Temperature 0 to 55 °C. Protection Surge protection on sensor inputs, over voltage and reverse polarity protection on Power Input. Storage 256MB (Industrial microSD). Interface(s) 2 x EIA RS485, 1 x R$232. 8 x 4-20mA (1% FS) USB Host 1 (USB 2.0) Voltage 9-24 VDC 10% (Nominal 12VDC) Power SW (peak) • Statistical data analysis (customizable) for average, min... max., diurnal variation. Auto report to the system should be two way. The data should be received at a central location and should be displayed there in real-time in graphical and tabular format... Operating Temperature 0 to 55 °C. Protection Surge protection on sensor inputs, over voltage and reverse. polarity protection on Power Input. Storage 256MB (Industrial microSD) Interface(s) 2x EIA RS485, 1 x RS232, 8 x 4-20mA (21% FS) USB Host 1 (USB 2.0) Voltage 9-24 VDC 10% (Nominal 12VDC) Power 5W (peak)• Statistical data analysis (customizable) for average, min., max, diurnal variation. Auto report and, auto mail generation etc.• Comparison of parameters of different locations in user selectable time formats i.e. in graphical and tabular formats compatible to MS. Excel, MS Word, txt etc. Including Mandatory fee for DATA transmission to CPCB, RSPCB & MCC server (whenever payable).• Ultrasonic open channel flow meter with shall comprise of Flow sensor / transducer, flow transmitter, digital level indicator/ remote indicator. control unit• Operating Temperature: 0 to 50°C. Safety: Explosion Proof or Intrinsically Safe.• Measuring Principal: Ultrasonic.•Communication Protocol: Open Protocol like MODBUS, PROFIBUS, HART, etc. Analog Output: Isolated 4-20mA, • Relay Contacts: Minimum of 3 SPDT contacts.•Accuracy: ± 0.25% of measured value or better.•Output. 4-20 mA • Protection a.) Sensor: IP-68. b.) Transmitter / Controller: IP-66 (NEMA 4X).•Display: LCD with LED backlighting 130
21 kva UPS • Capacity -1000VA/600W • Input Voltage Range 140 V 300 V AC Frequency 50 Hz ± 10%•Operating Temperature 0°C-40°C;•Charging Time 6-8 Hours recover to 90% capacity Battery Rating SMF 12V /7AHx2 Batteries,•Output Voltage 230 V AC Nominal Transfer Time Typical 4-8ms• Type Sealed Maintenance Free
3Comprehensive Operation & Maintenance Cost for whole system for 2nd year including data transmission to CPCB, RSPCB & MCC website, four service visits, two times Calibration of system in a year, repairable Cost, replacement cost. Consumables etc.
4Comprehensive Operation B Maintenance Cost for whole system for 3th year including data transmission to CPCB, RSPCB & MCC website, four service visits, two times Calibration of system in a year. repairable Cost, replacement cost, Consumables etc.
5Comprehensive Operation & Maintenance Cost for whole system: for 4th year including data transmission to CPCB, RSPCB & MCC website, four service visits, two times Calibration of system in a year. repairable Cost, replacement cast, Consumables etc.
6Comprehensive Operation & Maintenance Cost for whole system for 5 year including data transmission to CPCB, RSPCB & MCC website, four service visits, two times Calibration of system in a year, repairable Cost, replacement cost, Consumables etc.

AI Tender Summary

OUR REF NO 35037037
AUTHORITY Local Bodies
TENDER VALUE 22 Lakhs
LAST DATE 08-12-2022
Authority
Authority Name Department Of Local Bodies
Work Description Supply And Installation And Maintenance Of Ocems I.E Ph, Bod, Cod, Tss And Flow Along With 5 Year Comprehensive Operation And Maintenance As Well As Data Trasnger To Cpcb And Rspcb Server For Running 1.5Mld Stp At Near Kali Mangri Roadbarisadri Outlet , Supply , Installation, Testing & Commissioningof On Line Bod / Cod / Tss / Ph / Flow Meter In-Situ Based Analyzer As Percpcb Guideline For Online Continuous Effluentmonitoringsystem ( Ocems ) July 2018 With Panel For S.T.P. Effluent Measurement Items Uv-Vis Spectrometry Double Beam With Entire Spectrum Scanning 200 -720 Mm 190- 750Mm Wave Lengths Along With 256 Unique Pixel Diode. Make-Tethys / Xylem / Real Tech / Hach / Abb As Approved By Engineering In Charge ( All The Materials / Equipment And Apparatus Shall Be Got Approved By The Engineer In Charge Before Procurement Of The Items And There After Use In The Work. • Moc Of Bod / Cod / Tss Sensor -Titanium 3.7 F Ss316l Better • Cleaning Facility-Ultrasonic Cleaning Or Air Pressure Cleaning • Accuracy Of Bod / Cod / Tss Sensor-+ / -3% Of The Measured Value Light Source: Xenon Flash Lamp Or Following Measuring Ranges Are Required: Cod: 0-700 Mg / Ibod 0-400 Mg / 1 Tss: 0-600 Mg / 1 Ph Range 0 14 • Moc Of Ph. Sensor-Stainless Steel 316 Or Better Ph Accuracy + / 0.2% Protection Type: Ip 68 For Both The Sensor And Cable ( Cable ) Lengths Per Site Requirement ) Controller / Display- Housing Material Non Corrosive E.G. Acryl Onitrile-Styrene Acryl Ester Polymer Or Better • Protection Rating Ip 67 Controller / Display Cabin Box Should Be Ip66 Grade With Lock & Key Ss304 Grade Moc • Data Logger ( Including Data Transmission To Cpcb And Rspcb ) , Internet For Data Transmission Is In Bidders’ Scope. The Communication To The System Should Be Two Way The Data Should Be Received At Central Location And Should Be Displayed There In Real-Time In Graphical And Tabular Format. Operating Temperature 0 To 55 °C. Protection Surge Protection On Sensor Inputs, Over Voltage And Reverse Polarity Protection On Power Input. Storage 256Mb ( Industrial Microsd ) . Interface ( S ) 2 X Eia Rs485, 1 X R$232. 8 X 4-20Ma ( 1% Fs ) Usb Host 1 ( Usb 2.0 ) Voltage 9-24 Vdc 10% ( Nominal 12Vdc ) Power Sw ( Peak ) • Statistical Data Analysis ( Customizable ) For Average, Min... Max., Diurnal Variation. Auto Report To The System Should Be Two Way. The Data Should Be Received At A Central Location And Should Be Displayed There In Real-Time In Graphical And Tabular Format... Operating Temperature 0 To 55 °C. Protection Surge Protection On Sensor Inputs, Over Voltage And Reverse. Polarity Protection On Power Input. Storage 256Mb ( Industrial Microsd ) Interface ( S ) 2X Eia Rs485, 1 X Rs232, 8 X 4-20Ma ( 21% Fs ) Usb Host 1 ( Usb 2.0 ) Voltage 9-24 Vdc 10% ( Nominal 12Vdc ) Power 5W ( Peak ) • Statistical Data Analysis ( Customizable ) For Average, Min., Max, Diurnal Variation. Auto Report And, Auto Mail Generation Etc. • Comparison Of Parameters Of Different Locations In User Selectable Time Formats I.E. In Graphical And Tabular Formats Compatible To Ms. Excel, Ms Word, Txt Etc. Including Mandatory Fee For Data Transmission To Cpcb, Rspcb & Mcc Server ( Whenever Payable ) . • Ultrasonic Open Channel Flow Meter With Shall Comprise Of Flow Sensor / Transducer, Flow Transmitter, Digital Level Indicator / Remote Indicator. Control Unit • Operating Temperature: 0 To 50°C. Safety: Explosion Proof Or Intrinsically Safe. • Measuring Principal: Ultrasonic. •Communication Protocol: Open Protocol Like Modbus, Profibus, Hart, Etc. Analog Output: Isolated 4-20Ma, • Relay Contacts: Minimum Of 3 Spdt Contacts. •Accuracy: ± 0.25% Of Measured Value Or Better. •Output. 4-20 Ma • Protection A. ) Sensor: Ip-68. B. ) Transmitter / Controller: Ip-66 ( Nema 4X ) . •Display: Lcd With Led Backlighting 130 , 1 Kva Ups • Capacity -1000Va / 600W • Input Voltage Range 140 V 300 V Ac Frequency 50 Hz ± 10% •Operating Temperature 0°C-40°C; •Charging Time 6-8 Hours Recover To 90% Capacity Battery Rating Smf 12V / 7Ahx2 Batteries, •Output Voltage 230 V Ac Nominal Transfer Time Typical 4-8Ms • Type Sealed Maintenance Free , Comprehensive Operation & Maintenance Cost For Whole System For 2Nd Year Including Data Transmission To Cpcb, Rspcb & Mcc Website, Four Service Visits, Two Times Calibration Of System In A Year, Repairable Cost, Replacement Cost. Consumables Etc. , Comprehensive Operation B Maintenance Cost For Whole System For 3Th Year Including Data Transmission To Cpcb, Rspcb & Mcc Website, Four Service Visits, Two Times Calibration Of System In A Year. Repairable Cost, Replacement Cost, Consumables Etc. , Comprehensive Operation & Maintenance Cost For Whole System: For 4Th Year Including Data Transmission To Cpcb, Rspcb & Mcc Website, Four Service Visits, Two Times Calibration Of System In A Year. Repairable Cost, Replacement Cast, Consumables Etc. , Comprehensive Operation & Maintenance Cost For Whole System For 5 Year Including Data Transmission To Cpcb, Rspcb & Mcc Website, Four Service Visits, Two Times Calibration Of System In A Year, Repairable Cost, Replacement Cost, Consumables Etc.
Basic Detail
Tender No SBM/No. 1751-56 DATED 28-11-2022
Bidding Type Tender
Location
City Chittorgarh
State Rajasthan
Key Dates
Publish Date 29 Nov 2022
Submission Date 08 Dec 2022
Open Date 09 Dec 2022
Finance
Tender Value 22 Lakhs
Tender Fee 500
EMD 44000
Exemption Not Available
Document List
13488fd0-5ba5-4f08-9910-5a63390e1079.html
BOQ_545555.xls
tenderdocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 29, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 08, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 09, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

13488fd0-5ba5-4f08-9910-5a63390e1079.html

xls

BOQ_545555.xls

pdf

tenderdocument.pdf

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders