Tender For Electrification Work In Samiti Faridpur Bhavan, faridpur-Uttar Pradesh

Cane Development and Sugar Industry has published Tender For Electrification Work In Samiti Faridpur Bhavan. Submission Date for this Tender is 14-12-2022. Brushes Tenders in faridpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35027772
Corrigendum : Tender For Electrification Work In Samiti Faridpur Bhavan
Open Tender
Indian
Uttar Pradesh
faridpur
14-12-2022

Tender Details

Electrification Work In Samiti Faridpur Bhavan- 1 Wiring Point For Light With 1.5 Sq.Mm.Frlshpvcinsulated Multistrand Single Core Copper Conductor Cablein Heavy Guage Rigid Steelconduit Pipe Partly Concealed In The Walland Partly Laidinslab Alongwith The Reinforcement Before Concreting, Complete With 14 Swg Copper Earth Continuity Wire, Gp Box , Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3Mm Thickphenolic Paminated Backalite Sheet Etc Complete In All Respect As Directed Including Matching Colour Wash. 2 Wiring For Group Controlled ( Looped ) Light Point / Fanpoint / Exhaust Fan Point / Call Bell Point ( Without Independentswitch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copperconductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulatedcopper Conductor Single Core Cable Etc. As Required.Group B 3 Wiring Point For Two Ways Light With 1.5 Sq. Mm. F.R. Pvcinsulated Multistrand Single Core Copper Conductor Cable In Heavy Guage Rigid Steel Conduitpipe Partly Concealed In The Walland Partly Laid In Slab Alongwith The Reinforcement Before Concreting, Complete With 14 Swg Copper Earth Continuitywire , Gp Box Andtwo Number Two Waypiano Type Switches & Ceiling Rose / Angle / Batten Holder On 3 Mm Thick Phanolic Laminated Backelite Sheet Etc., Complete In Allrespect, As Directed, Including Matching Colour Wash. 4 Wiring Point For Fan / Fresh Air Fan ( Light Duty Exhaust Fan ) With 1.5 Sq.Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Heavy Guage Rigid Steel Conduit Partly Concealed In Wall And Partly Laid In Slab Alongwith The Reinforcement Before Concreting, Complete With 14 Swg Copper Earth Continuity Wire, Gp Box , Piano Type Switch & Ceiling Rose On 3 Mm. Thick Backelite Sheet Etc., Complete In All Respect Including Matching Colour Wash. 5 Wiringpointforplugwith 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable Inheavyguagerigidsteel Conduit Partly Concealed In Wall And Partly Laid In Slab Alongwith The Reinforcementbefore Concreting, Complete With14 Swg Copper Earth Continuity Wire And Piano Typeswitch And Socket Etc., Complete In All Respect Including Matching Colour Wash. 6 Wiring Point For Exhaustfan With 1.5 Sq. Mm.Frlshpvc Insulated Multistrand Single Core Copper Conductor Cable In Heavy Guage Rigid Steel Conduit Partly Concealed In Wall And Partly Laid In Slab Alongwith The Reinforcement Before Concreting, Complete With 14 Swg Copper Earth Continuity Wire, Gp Box , 15A Piano Type Switch& Ceiling Rose On 3 Mm Thick Phenolic Laminated Backelite Sheet Etc., Complete In All Respect Including Matching Colour Wash. 7 Same Asin Item 148, But 25Mm Dia 16 Swg ( 1.5 Mm ) Thickrigid Steel Conduit. 8 Same As In Item 174 ( B ) But For Plug Point With 5 Amp Flush Typeswitch And 3 Pin Socket And Earth Continuity Wire Of1.5 Sq.Mm. Frlsh Pvc Insulated Multi Strand Copperconductor Cable. 9 Add For Light / Fan Points With Modular Type Switch In Place Of Piano Type Switch. 10 Add For 2 Way Light Point With Modular Switches In Place Of Piano Type Switches. 11 Add For Plug Point With Modular Switch & Socket In Place Of Piano Type Switch & Socket. 12 Add For Hpmv / Exhaust Fan Point With Modular Type Switch In Place Of Piano Type Switch. 13 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections Butexcluding Modular Plate Etc. As Required ( A ) Telephone Socket Outlet 14 ( B ) Sitc Of Rj 45 Dta Socket Outlet With Shutter. 15 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1 Or 2 Module ( 75Mmx75mm ) 16 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required.2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 17 Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pair 18 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.1 Run Of Cable 19 Supply And Wiring Of Submain Withtwo Number 4 Sq.Mm. Frlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Guage Rigid Steel Conduitpartly Concealedinwall Andpartlylaid In Slab Alongwith Reinforcement Before Concreting, With One Number 14 Swg Copper Earth Continuity Wire Including Matching Colour Washetc. Complete In All Respect. 20 Supply And Wiring Of4 Number 10 Sq. Mm. Frlsh Pvcinsulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 32 Mm Dia Heavy Guage Rigid Steel Conduit Partly Concealed In Wall And Partlylaidinslab Alongwithreinforcementbefore Concreting, With Two Number 10 Swg Copper Earth Continuity Wire Including Matching Colour Wash Etc, Complete In All Respect. 21 Supply And Wiring Of4 Number 16 Sq.Mm. Frlsh Pvcinsulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 40 Mm Dia Heavy Guage Rigid Steel Conduit Partly Concealedin Wall Andpartlylaidinslab Alongwithreinforcement Before Concreting, Withtwo Number 10 Swg Copper Earth Continuity Wire Including Matching Colour Washetc, Complete In All Respect. 22 Supply And Fixing Ofrecess / Surface / Pendentmounting Round 15 Watt Led Down Lighter Having Powder Coateddie Cast Aluminium Housing Withheat Sink, Diffuser / Reflector And Driver Set Complete In All Respect. Cat- Aaa 23 Supply And Fixing Ofrecess / Surface / Pendentmounting Round 15 Watt Led Down Lighter Having Powder Coateddie Cast Aluminium Housing Withheat Sink, Diffuser / Reflector And Driver Set Complete In All Respect. Cat- Aaa 24 Supply And Fixing Ofled Tube Light With Batten Suitable For Up To 2 X 22 Watt Led Tube Light Fittingincluding Tube On Surface Complete In All Respect.Cat- Aaa 25 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 26 Supplyandlayingof Aluminiumconductorpvcinsulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm. Thick Sand All Around And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. 16 Sq. Mm 4 Core 27 Supply And Fixing Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respect. The Armouring Ofthe Cable Shall Be Properly Connected With The Earth As Per Direction Of Engineer-Incharge.16 Sq. Mm 4 Core 28 Supply And Fixing Of Plain Or Pin Type Copper Tin Plated Cable Socket ( Lug ) To The Cable Leads, Insulating With Tape And Making Connection Etc. Complete In All Respect As Per Direction Of The Engineer-Incharge. 16 Sq. Mm 29 Supply And Burying Of 600Mm X 600Mm X 6Mm G.I. Plate Vertically For Earthing With Its Top At Least 3 Metres Below Ground Level Complete With 20Mm Dia G.I. Pipe And Funnel For Watering And One Earthing Lead Oftwo No. 8 To 10 Swg Gi Wire In 15Mm Dia G.I. Pipe Up To Switch Board ( From Appron To Switch Board The Cost Of G.I. Pipe And G.I. Wire Will Be Extra ) 30Cm Square C.I. Frame With Hinged Cover Masonry Housing Alternate Layers Of Charcoal / Coke And Salt At Least 150Mm Thick Alround Etc. As Per Directions Of Engineer-In-Charge Complete In All Respect. 30 Supply And Laying Of 25Mm X 3Mm G.I. Strip From Earth Electrode Directly In The Ground As Required Complete In All Respect. 31 S&F Surface / Flush Mounting 8Ways Spn Distribution Board With Additional Metal Door Without Mcb Complete In All Respect, As Directedbyengineer In Charge. Cat-A 32 S & F Surface / Flush Mounting 6Ways Tpn Distribution Board With Additional Metal Doorwithout Mcb Complete In All Respect, As Directed At Site Byengineer In Charge. Cat-A 33 S & F Surface / Flush Mounting 8Ways Tpn Distribution Board With Additional Metal Doorwithout Mcb Complete In All Respect, As Directed At Site Byengineer In Charge. Cat-A 34 S&F Of6 Amp. To 32Amp. Dp Mcb ( 10 Ka ) C Curvecat-A 35 S&F Of 6 Amp. To 32Amp. 4 Pole Mcb ( 10 Ka ) C Curve Cat-A 36 S&F Of 63Amp. 4 Pole Mcb ( 10 Ka ) C Curve Cat-A 37 S&F Of 6 Amp To 32 Amp. Spmcb ( 10 Ka ) C Curve Cat-A 38 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 25 A 39 Supplying And Fixing Following Rating, Double Pole, ( Single Phaseand Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired.40 A 40 Erection And Testing Of Ceiling Fan And Regulator For Room Height Upto 3.5 Metres Including Supply Of 3Mm Thick G.I.Pipe19mm Dia. Duly Painted, Complete In All Respect. 41 Supply And Fixing Of 16 Swg M.S. Drum With Luvers Duly Painted Including Making Hole In The Wall For Exhaust Fan And Finishing Properly Complete In All Respect. 42 Supply And Laying Of 1800Mm X 900Mm X 12Mm Thick Chequered Rubbbber Matting Of Tested Quality. 43 Supply And Fixing Of Power Plug With 20 Amp. / 250 Voltflush Type Modular Switch And 5 Pin 20 A / 250 Volt Flush Type Universal Modular Socketswitch On Concealed M.S Boxincluding Supply Of All Material, Labour T&P Etc. Required For Proper Completion Of Work. 44 Supply And Fixing Hexagonal Round G.P.Fan Box Approved Make Made Up Of 1.0 Mm Thickisi Marked G.P.Sheet Spot Welded Four To Eightholes For Pipe Entryof The Box. Holes Should Be Semi-Shuttered Type With 0.5 Mm G.P. Sheet Made Upper & Lower Cover Duly Screwed. Fixing With Wiring Conduit Laid In The R.C.C. Roof Before Concretingalongwith Supply Of All Material, Labour, T&P Etc. Required For Proper Completion Of The Work. 45 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, C Curve Including Connections, Painting Etc. As Required. 46 Supply And Fixing Of Electronic Fan Regulator ( Modular ) 120-280 V. Isi Marked, On The Existing Switch Board Including Making Connections, Required Material, Labour T&P Etc. For Proper Completion Of Work To The Satisfaction Of Engineer In Charge Of Work. 47 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 200 Mm Dia ( Od-200 Mm & Id-175 Mm Nominal ) 48 Supply Of Totally Enclosed Exhaust Fan, 300Mm Sweep Continously Rated Highly Efficient Heavy-Dutymotor Similar To Crompton Cat. Ref. Trans Air 12 Or Equivalent. 49 Main L.T Paneldesign, Manufacturing, Supply, Commissioning & Testing Of Main Lt Panel. The Panel Will Be Totally Enclosed Type With, Free Standing, Floor Mounted, Indoor Duty, Dust & Vermin Proof, , Front Operated, Electrical Panel Fabricated From 2 Mm Thick M.S. Sheetas Per Specifications & Drawing Laid In This Document And Will Be Complete With The Main And Auxiliary Bus Bars, Multimeter, Indication Lamps, CtS, Protection Mcb, Interconnection Wiring, Earth Bus And Will Be Powder Coated Finish With 50 Micron Thickness.The Main Lt Panel Shall Use All Draw Out Type Breakers Suitable For 415 V Ac, 3 Phase, 50 Hz, 3 Phase 4 Wire Supply System. The Panel Shall Haveamf Facilityto Achieve Electrical Interlocking, Synchronizing, Buscoupler Switching, Auto Operation Of Incommer And Bus Coupler, Auto Start Of D.G. Sets, Auto D.G. Running By Pre Set Timing, Auto Changeover Etc And Having Following Incomming And Outgoing Air Circuit Breakers, FsuS As Per The Drawing And Specification. Each Incoming Breaker Will Have Microprocessor Based Releases And All Outgoing Breaker Will Have Minimum Electrostatic Releases Over 250A & Thermal Magnetic Release Below 250A. The Panel Will Be Made As Per Detailed Specifications & Drawings Forming Part Of This Document. Fault Level Of Panel Shall Be 35 Mva. 50 Along With Paerapets To Allow Unhindered Longitudinal 51 Of Water ( As Per Sheer Attached

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Dec-2022 DATE Date 14-12-2022

Key Value

Document Fees
INR 840 /-
EMD
INR 125000.0 /-
Tender Value
INR 12.44 Lakhs /-

BOQ Items

Name of Work: electrification work in Samiti Faridpur Bhavan
Sl. No. Item Description
1Wiring point for light with 1.5 sq.mm.FRLSHPVCinsulated multistrand single core copper conductor cablein heavy guage rigid steelconduit pipe partly concealed in the walland partly laidinslab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose/angle/batten holder on 3mm thickphenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash.
2Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
3Wiring point for two ways light with 1.5 sq. mm. F.R. PVCinsulated multistrand single core copper conductor cable in heavy guage rigid steel conduitpipe partly concealed in the walland partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuitywire , GP Box andtwo number two waypiano type switches & ceiling rose / angle / batten holder on 3 mm thick phanolic laminated backelite sheet etc., complete in allrespect,as directed, including matching colour wash.
4Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash.
5Wiringpointforplugwith 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable inheavyguagerigidsteel conduit partly concealed in wall and partly laid in slab alongwith the reinforcementbefore concreting, complete with14 SWG copper earth continuity wire and piano typeswitch and socket etc., complete in all respect including matching colour wash.
6Wiring point for exhaustfan with 1.5 sq. mm.FRLSHPVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , 15A piano type switch& ceiling rose on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect including matching colour wash.
7Same asin item 148, but 25mm dia 16 SWG (1.5 mm)thickrigid steel conduit.
8Same as in item 174(B) but for plug point with 5 Amp flush typeswitch and 3 pin socket and earth continuity wire of1.5 sq.mm. FRLSH PVC insulated multi strand copperconductor cable.
9Add for light / fan points with modular type switch in place of piano type switch.
10Add for 2 way light point with modular switches in place of piano type switches.
11Add for plug point with modular switch & socket in place of piano type switch & socket.
12Add for HPMV/Exhaust fan point with modular type switch in place of piano type switch.
13Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required (a)Telephone socket outlet
14(b) SITC of RJ 45 dta socket outlet with shutter.
15Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
16Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
17Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
18Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
19Supply and wiring of submain withtwo number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduitpartly concealedinwall andpartlylaid in slab alongwith reinforcement before concreting, with one number 14 SWG copper earth continuity wire including matching colour washetc. complete in all respect.
20Supply and wiring of4 number 10 sq. mm. FRLSH PVCinsulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy guage rigid steel conduit partly concealed in wall and partlylaidinslab alongwithreinforcementbefore concreting, with two number 10 SWG copper earth continuity wire including matching colour wash etc, complete in all respect.
21Supply and wiring of4 number 16 sq.mm. FRLSH PVCinsulated 1100 V grade multistrand single core copper conductor cable in 40 mm dia heavy guage rigid steel conduit partly concealedin wall andpartlylaidinslab alongwithreinforcement before concreting, withtwo number 10 SWG copper earth continuity wire including matching colour washetc, complete in all respect.
22Supply and fixing ofrecess/ Surface/ Pendentmounting round 15 Watt LED Down Lighter having Powder coateddie cast aluminium housing withheat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA
23Supply and fixing ofrecess/ Surface/ Pendentmounting round 15 Watt LED Down Lighter having Powder coateddie cast aluminium housing withheat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA
24Supply and fixing ofLED Tube Light with batten suitable for up to 2 X 22 watt LED tube light fittingincluding tube on Surface complete in all respect.CAT- AAA
25Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
26Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core
27Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring ofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge.16 sq. mm 4 core
28Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 16 sq. mm
29Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead oftwo no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect.
30Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.
31S&F surface/flush mounting 8ways SPN distribution board with additional metal door without MCB complete in all respect, as directedbyEngineer in charge. Cat-A
32S & F surface/Flush mounting 6ways TPN distribution board with additional metal doorwithout MCB complete in all respect, as directed at site byEngineer in charge. Cat-A
33S & F surface/Flush mounting 8ways TPN distribution board with additional metal doorwithout MCB complete in all respect, as directed at site byEngineer in charge. Cat-A
34S&F of6 Amp. to 32Amp. DP MCB (10 KA) C CurveCat-A
35S&F of 6 Amp. to 32Amp. 4 pole MCB (10 KA) C Curve Cat-A
36S&F of 63Amp. 4 pole MCB (10 KA) C Curve Cat-A
37S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve Cat-A
38Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
39Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
40Erection and testing of ceiling fan and regulator for room height upto 3.5 metres including supply of 3mm thick G.I.Pipe19mm dia. Duly painted, complete in all respect.
41Supply and fixing of 16 SWG M.S. drum with luvers duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect.
42Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality.
43Supply and fixing of power plug with 20 Amp./250 voltflush type modular switch and 5 pin 20 A/250 volt flush type universal modular socketswitch on concealed M.S boxincluding supply of all material, labour T&P etc. required for proper completion of work.
44Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thickISI Marked G.P.sheet spot welded Four to Eightholes for pipe entryof the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concretingalongwith supply of all material, labour, T&P etc. required for proper completion of the work.
45Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
46Supply and fixing of electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.
47Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal)
48Supply of Totally enclosed exhaust fan, 300mm sweep continously rated highly efficient heavy-dutymotor similar to Crompton Cat. Ref. Trans Air 12" or equivalent.
49MAIN L.T PANELDesign, Manufacturing, Supply, Commissioning & Testing of Main LT Panel. The panel will be totally enclosed type with, free standing, floor mounted, indoor duty, dust & vermin proof, , front operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CT"s, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness.The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall haveAMF facilityto achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU"s as per the drawing and specification. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases over 250A & thermal magnetic release below 250A. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA.
50along with paerapets to allow unhindered longitudinal
51of water (as per sheer attached
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail