Tender For Ca No Ge/H-32/2022-23 Name Of Work Comprehensive Maintenance Of Ot Light Nurse Call System At Ahrr And Ups Of Ctvs Centre And Adc And Other Misc Works Under Ge Em Rr Hosp Delhi Cantt 10, delhi-Delhi

Military Engineer Services-MES has published Tender For Ca No Ge/H-32/2022-23 Name Of Work Comprehensive Maintenance Of Ot Light Nurse Call System At Ahrr And Ups Of Ctvs Centre And Adc And Other Misc Works Under Ge Em Rr Hosp Delhi Cantt 10. Submission Date for this Tender is 24-12-2022. Electrical Maintenance Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35010902
Corrigendum : Tender For Ca No Ge/H-32/2022-23 Name Of Work Comprehensive Maintenance Of Ot Light Nurse Call System At Ahrr And Ups Of Ctvs Centre And Adc And Other Misc Works Under Ge Em Rr Hosp Delhi Cantt 10
Open Tender
Indian
Delhi
delhi
24-12-2022

Tender Details

Comprehensive Maintenance Of Ot Light Nurse Call System At Ahrr And Ups Of Ctvs Centre And Adc And Other Misc Works Under Ge Em Rr Hosp Delhi Cantt 10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 62600.0 /-
Tender Value
INR 31.30 Lakhs /-

BOQ Items

Name of Work :-COMPREHENSIVE MAINTENANCE OF OT LIGHT, NURSE CALL SYSTEM AT AHRR AND UPS OF CTVS CENTRE AND ADC AND OTHER MISC WORKS UNDER GE E/M RR HOSP DELHI CANTT-10
Sl. No. Item Description
1Comprehensive Maintenance of Wired/Wireless multi services Nurse Call System and patient call system installed at AHRR,of following location, employing 01 technician having qualification of ITI in electrical/electronics engineering with adequate experience in the general shift from 0900 hrs to 1700 hrs including Sunday and holiday to make the system functional in following wards :- (i) Main Bldg AHRR- 597 Nos bed unit and 24 Nos display (ii)CTVS Centre - 257 Nos bed unit and 12 Nosdisplay(iii) ADC - 8 nos Display unit of patient call system Notes : (i)Preventive & routine repair/maintenance of Wireless Display and controlling units. (ii) Preventive &routine repair/maintenance of Wireless Bed Units (iii)Preventive & routine repair/maintenance of DC 12V batteries for Bed Units (iv)Preventive repair & Maintenance of all systems on monthly basis and upkeep of log book. (v) Attendingto all complaints within 24 hours failling which penal recovery@ Rs 500.00 /complaint per day will be effected from contractor"s dues (vi)Field Service Reports will be maintained and submitted to the concerned JE(MES) whenever required.(vii) All spares parts included in quoted rates excluding wireless bed unit and wireless display and controlling unit.(viii)The complete work is to be carried out through the OEM & MOU from thecompanies must be submitted before commencement of work.
2Comprehensive.preventive and periodical maintenance and checking serviceability of on line UPSinstalled in various switch rooms/Wards/Dept of CTVS Centreand Army Dental Centre as per manufacturer"s recommendation in reliable safe and efficient manner using latest technique & expert consultancy by regularly examining and adjusting the mechanical & electrical driving equipment including replacement of defective /spare parts/items as and when required by employing 01 technician having qualification of ITI or diploma in electrical/ electronics engineering with adequate experience in the general shift from 0900 hrs to 1700 hrs including Sunday and holidaycomplete all as directed to entire satisfction of Engineer-in-charge.(i) 20 KVA UPS-05 Nos (Sinetrac/ lebotek)(ii)30 KVA UPS - 12 Nos ( Luminious) Notes : (i) The costof all defective /userviceable spare parts/items required to be replaced is deemed to be included in the rate quoted by contractor excluding battery and Transformer. (ii) Cost of any item and extra manpower required to make the system functional is deemed to be included in the rate quoted by the contracor.(iii)The contractor shall attend the complaints of UPS on receipt at any time round the clock including Sunday and Holiday and the cost of the same is deemed to be included in the rates quoted. The penalty for non attending the complaints of UPS upto six hrs shall be Rs. Rs.1000/-per day. (iv) Maint/ repair as enumerated above shall be under taken by the manufacturer or their authorized dealer/ rep. (v)The dust cleaning shall be carried out of each UPS in a week.(vi)The elect connections shall be checked regularly for looseness / tightening the same.(vii)The fortnightly periodical maint shall be carried out in rotation apart from breakdown for each UPS and record of same to be maintained duly signed by contractor rep and MES rep. (viii) The complete work is to be carried out through the OEM & MOU from the companies must be submitted before commencement of work.(ix)Rate quoted by contractor for this item does not include replacement of battery and main transformer .
3Comprehensive, preventive and periodical maintenance of OT Lights (21 Nos) of installed at OT Complex of main bldg of AHRR, CTVS Centre and Army Dental Centre as per manufacture recommendation, in reliable, safe and efficient manner using latest techniques & expertise consultancyby o1 technician having qualification of ITI in electrica//electronics in general shiftfrom 0900h to 1700hincluding sunday and holiday, and adjusting the mechanical and electrical driving equipment incl replacement of minor defective / spares parts/items i.e.lamp including complete accessories likes driver, ballast etc and wire, lugs, nut, bolts, screws etcas and when required, complete all as directed to entire satisfaction of Engr-in-charge. (i) Main Bldg Hospital(P-100)- 09 Nos(Dragger, Philips)(ii) CTVS Centre- 07 Nos( Philips)(iii) Army Dental Centre - 05 Nos (Phillips) Note:(i)The cost of all kind of minor spares parts/items i.e. nut, bolt, washer, fastner etc is deemed to be included in the quoted rates. (ii) The cost of transportation (to and fro), skilled manpoer and other necessary equipment shall be arranged / brought by contractor to complete the job at site only and no extra cost shall be paid to the contractor in this effect. (iii)The complete work is to be carried out through the OEM & MOU from the companies must be submitted before commencement of work.(v) The penalty for non attending the complaints upto six hrs shall be Rs. 500/-,per day.
4Supply and installation including testing and commissioning of SMF Battery 12 Volts, 26 AH with battery copper terminals/thimples, battery inter-connection copper cable 16 Sqmm etc, complete all as directed.Note:-Minimum Replacement manufacture warranty for 2 years.
5All as per srl item No 4 here-in- before but SMF battery 42 AH
6All as per srl item No 4 here-in- before but SMF battery 65 AH
7Supply and fix in replacement and testing commissioning of wireless mltiservice for three service call ( Nurse Calling, House Keeping and Code Blue) Bed unitand reset with wireless door indicator, with built-in RFAF, environment condition, operating temp 0 degree centigrade-50 degree centrigade( 32 degree F - 122 degree F) operating voltage humidity 10%-90% without congealment power requirement, operating voltage 12 Voltage battery opearing current -standby< 10 mA, working status < 10 mA packing contents wireless bed unit button with handset DC 12V battry screws and mounting plate including fixing accessories, complete all as directed.
8Supply and fix in replacement and testing commissioning of wireless displayunit with human voice address and built-in RFAF frequency attention filter , having the following specification complete all as directed :- (i)Capacity : Max 50 beds, 7 seg LED display max, 2 digit for one bed receiving 3 LED indicators ( Nurse Calling, House Keeping and Code Blue)(ii)Power reqirement: AC 230 V, 5Amps, 50 Hz(iii) Operating Temp: 0 to 50 degree ( 32 degree F - 122 dgreeF) (iv) Operating Humidity: 10%-90% without congealment(v) Operating Voltage : 05 volt DC-12 volt DC(vi)Operating current: 200mA, Standy<30mA, Full load<35mA(vii)Startup current: 600 mA (viii) Speaker : Full duplex(ix) Impedence: 8C + 15%(x)Max outout Power :0.5 W (xi) Distribution Rate : 5% Max(xii) Max dB : 89 + 3dB (xiii)Frequency Range:50 Hz to 10 KHz
9Supply and fix in repair wired multi service Handset with 2 metre long for three service calling (Nurse Calling, House Keeping and Code Blue)and reset facility and door Indicator, complete all as specified and directed by Engineer-in-charge.
10Supply and fix in repairs UPS transformer copper wound suitable for UPS for 20 KVA ( 3 phase input and 1 phase output) includidng testing complete all as specified and directed by Engineer-in-charge.
11Supply and fix in repairs UPS transformer copper wound suitable for UPS for 30 KVA ( 3 phase input and 1 phase output) includidng testing complete all as specified and directed by Engineer-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail