Tender For Construction Of Kitchen Cum Store Room At Horticulture College, Khuntpani, West Singhbhum, Chaibasa Under Bau, Kanke, Ranchi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Dec 2022
0 days left
EMD
30000
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
khuntpani → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Kitchen Cum Store Room At Horticulture College, Khuntpani, West Singhbhum, Chaibasa Under Bau, Kanke, Ranchi
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil ( vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling,ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of Ei I |
| 2 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I |
| 3 | Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) cum 7210.55 |
| 5 | providing designation 75A brick work in C.M.(1:6) in foundation and plinth -do |
| 6 | Providing 25mm thick damp proof course with cement concrete M-150 with nominal mix of (1:2:4) with approved quality of stone chips of 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with 5% cico or any other approved water proffing compound and placing in position, striking, curing, taxes and royalty all complete, as per building specification and direction of E/I |
| 7 | Providin designation 75A Brick work in C.M.(1.6) In superstructure -do-- |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Providing Tor steel reinforcement of 8mm mm dia rods as per approved -do-TMT Fe 500 (Only valid for Tata (Tiscon). SAIL, JSPL, Electrosteel Steel Ltd. Bokaro and Vizag (RINL)). |
| 10 | Providing Tor steel reinforcement of 10 mm ,12 mm ,16 mmdia rods as per approved design and drawing- do--a) 10 mm TMT Fe 500 (Only valid for Tata (Tiscon). SAIL, JSPL, Electrosteel Steel Ltd. Bokaro and Vizag (RINL)). |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 12 | Providing 12mm thick plaster (1:6) with clean coarse sand of FM 1.5 including screening curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 13 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I |
| 14 | Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm M.S. square bars fitted on 25x25x6mm M.S. Angle frame of size 60x60x6mm including cost of fabrication providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I (when steel is not supplied |
| 15 | Supplying,fitting and fixing 20 guage G.C.l. sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication, pro viding necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1.2.4 ) blocks of required size, applying a primingred lead paint over steel work, taxes all complete as per drawing specrfication and direction of E/|. |
| 16 | Reinforcedcementconcreteworkinbeams,suspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 17 | Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required |
| 18 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK 20 MM DIA |
| 20 | 25 MM DIA |
| 21 | c) 32 mm dia |
| 22 | Providing and fixing Special type of C.P, Bathroom fittings for V.I.P building (JAL, Jaquar, Marc or equivalent mark) all complete as per specification and direction of E/ |
| 23 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 24 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing taxes and royalty all complete as per building specification and direction and of E/I |
| 25 | Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1)limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 26 | Providing two coats of synthetic enamel paint & Providing primer one coat of red lead paint approved shade and made over steel surfaceincluding cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I |
| 27 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 28 | Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . 4.0 mm (Cost of aluminium snap beading shall be paid in basic item): |
| 29 | Stainless steel wire guage (Grade-304) aperture 1.4 mm and 0.50 mm dia wire |
| 30 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 31 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 32 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 33 | Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.For kitchen wastage |
| 34 | CARRAIGE SAND |
| 35 | STONE CHIPS |
| 36 | BRICKS |
| 37 | EARTH |
| 38 | Wiring for light point/fan point/ Exhaust fan point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required.Group A |
| 39 | Wiring for circuit/submain wiring along with earth wire with the following size of FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required.2x2.5 sq.mm +1x2.5 sq.mm earth wire |
| 40 | 2x4.0 sq.mm +1x4.0 sq.mm earth wire |
| 41 | Supplying, providing and fixing of suitable size PVC/GI boxwithmodular plate cover in front on surface or in recess including providing and fixing 6 pin 15/16 amp modular socket outlet with 15/16 amp modular switchas required. |
| 42 | Supplying & fixing of following modular type switch/socket on the existing modular plateand switch box including connection etc as required.a) 5/6 Amp switch |
| 43 | b)5/6 Amp3 pin socket outlet |
| 44 | Supplying and fixing of following way horizontal type three pole and neutral sheet steel ,MCB distribution board ,415 volt on surface/recess complete with tinned copper busbar ,neutral bar (but without MCB/RCCB/ISOLATOR)4way (4+12),D.DoorHoronzontaltupe |
| 45 | Supplying and fixing following 240 volts C series ,miniature circuit breaker suitable for inductive loads of following poles in existing MCB DB complete with connection as required.6/32 amps,Single pole |
| 46 | 50/63 amps ,tpn |
| 47 | Earthing with copper earth plate 600mmx600mmx3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe (with charcoal Or coke and salt ) as required. |
| 48 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor eartelectrode ,including soldering etc as reqired. |
| 49 | S.I.T.C of following rating LED Flood lighting luminaries with pressure die cast housing and toughened glass cover,IP 66 protection, LUMINIOUS EFFICARY 110LM/W, with lens in existing pole/pipe for supply voltage100-270v AC, 50Hz Luminaries shall confirm to IS;10322 part- 5/section-5 and shall be complete with allnecessary accessories as required.30W LED Flood light |
| 50 | 90/100W LED Flood light |
| 51 | Supplying following sizes and core PVC/XLPE insulated PVC sheated ,heavy duty , electric cable with for working voltage upto and including 1100 volt. Make –Havells/ Polycab or equivalent.50sq.mm 3.5 core |
| 52 | FR PVC insulated 3 core 4 sq.mm copper wire (for flood light ) |
| 53 | Laying of one number PVC insulated and PVC sheated /XLPE power cable of 1.1 KV grade of size exceeding 35 sq.mm but not exceeding 95 sq.mm direct in ground including excavation and refilling the trench as required but excluding sand cushioning and protective covering. |
| 54 | Supplying and fixing of cable junction box comlete with connection as required. MAKE –Sintex or equivalent. |
| 55 | SITC of following rating surface mounted LED Tube light fitting suitable for 230 V 50Hz single phase supply etc complete as required.20/22 W LED Tube Light |
| 56 | Supplying and fixing of 450mm (18’’)metal body wall fan with speed regulator suitable for single phase 220 V,50Hz Ac supply |
| 57 | Supplying and fixing of 15’’ (380mm)metal exhaust fan complete with connection as required. |
| 58 | Supplying of 1100 to 1200 VA sine wave inverterinput AC range-100 V to 300 V AC,wide 90V to 300 V AC standard -180V to 260V AC,DC range -10.5to 14.2 efficiency -80% protection overload, short circuitas per direction of E/I |
| 59 | Supplying and fixing 150 Ah tubular Lead acid batterywith 36 month replacement guaranty IS 1652:1991. |
| 60 | Trolly for Single tubular battery |
| 61 | Supplying and fixing 6 amp to 32 amps rating ,240 volt ,10KA C curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections ,testing and commissioning etc as required. 6/32 amps, DP |
| 62 | Labour welfare fund |
| 63 | GST @ 12 % |
AI Tender Summary
Tender Timeline
Nov 26, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedDec 02, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 05, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender