| 1 | Sch \"A\" Part-I B/R work:-Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out, all as specified and directed by Engr-in-Charge. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard dense soil. complete all as specified and directed by Engr-in-Charge. |
| 3 | Excavation over area not exceeding 1.5 m depth and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge |
| 4 | Excavation over area exc 1.50 m and not exceeding 3.00 m depth and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge |
| 5 | Excavation over area exc 3.00 m and not exceeding 4.50 m depth and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge |
| 6 | Excavation over area exc 4.50 m and not exceeding 6.00 m depth and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge |
| 7 | M & L for removing surplus soil to a distance exc 50 mte andnot exc. 100 mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 8 | M & L for removing surplus soil to a distance exc 100 mte andnot exc. 500 mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 9 | Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified. |
| 10 | M&L for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by the Engr-in-Charge. |
| 11 | M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete etc, complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for Precast cement concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge. |
| 13 | M&L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in flooring, PCC path, sub base and surface finished even and fair with out using extra cement all as specified and as directed. |
| 14 | M&L for plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints in 2nd Class Hardwood (KAIL) complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for mild steel work (angle iron or flat iron) as in hold fasts, wall ties, clamps, ventilator pipe, rain water pipe,band, straps, hooks for hanging fans, manhole covers, MS rungs and similar small articles conforming to Fe-310-O or Fe-410-O all as specified and as directed. |
| 16 | M & L for Cement Concrete , 1:2:4, type B1 using20mm graded agg as in lintel upto 1.50 m span, cills, steps, seismic and other silmilar bands, plinth courses, sring courses,lacing courses, parapets and railings upt 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 04028, water troghs and the like including weathering, slightly rounded or camphered angles and throating, complete all as specified and directed by Engr-in-Charge. |
| 17 | S&F mild steel TMT bars 10 mm dia and over,cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge. |
| 18 | S&F mild steel TMT bars 6 to 8 mm dia and over,cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge. |
| 19 | All as per item No. 18here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 20 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 21 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work includingattached pillasters, buttresses, etc.; vertical or to batter |
| 22 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick, fair finshed flat surfaces of concrete |
| 23 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 24 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions |
| 25 | M&L for RCCDesign mix, M-30 ( using 20 mm graded crushed stone aggregate ) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete (Note:-TMT bars will be masured and paid sepretly) |
| 26 | M&L for RCCDesign mix, M-30 ( using 20 mm graded crushed stone aggregate ) as in walls, retaining walls, basement, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttersses etc. complete all as specified and as directed. (Note:-TMT bars will be masured and paid sepretly) |
| 27 | M&L for RCCDesign mix, M-30 ( using 20 mm graded crushed stone aggregate ) as in slab supoported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc. complete all as specified and as directed. (Note:-TMT bars will be masured and paid sepretly) |
| 28 | M&L for RCCDesign mix, M-30( using 20 mm graded crushed stone aggregate ) as inBeams, cantilevers, bressummers, lintels over 1.5m span (Note:-TMT bars will be masured and paid sepretly) |
| 29 | M&L for RCCDesign mix, M-30 ( using 20 mm graded crushed stone aggregate ) as inColumns, pillars, piers, posts and struts(Note:-TMT bars will be masured and paid sepretly) |
| 30 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe 410 W (Gde-E-250) quality A. |
| 31 | S&F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc30cm long dia of neck exc. 12mm but n.exc. 20mm complete all as specified. |
| 32 | S&F structural steel works as in stair (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. and similar works confirming toFe-410-O or Fe-310-O. complete all as specified. |
| 33 | M&L for preparation of new surfaces of steel of any description , over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge .. |
| 34 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 35 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 36 | M&L Non skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed. |
| 37 | M&L for rendering 10mm thick on fair face of brick work or concrete/stone surfaces in CM 1:6and finished even and smooth without using extra cement.complete all as specified and directed by Engr-in-Charge. |
| 38 | M&L for plaster 15mm thick on fair face of brick work or concrete/stone surfaces in CM 1:6and finished even and smooth without using extra cement.complete all as specified and directed by Engr-in-Charge. |
| 39 | M&L for 3 coats of white wash on new plastered surfaces of wall including preparation of surfaces all as specified and as directed. |
| 40 | M&L for Glazed ceramic tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade of tiles including laid over backing coat of 10mm thick of cement mortar 1:4 all as specified and directed. |
| 41 | Rendering 15mm thick on fair face of brick work or concrete/stone surfaces in CM 1:4 mixing with WPC @2% by weight of cement or as per manufacturer instruction and finished even and smooth without using extra cement.complete all as specified and directed by Engr-in-Charge.Note:WPC will be measured and paid sepratly. |
| 42 | Supply only integral water proofing compound. |
| 43 | M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engr-in-Charge .. |
| 44 | M&L for 2nd class hardwood 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats for doors. |
| 45 | S&F 100mm long butt hinges, medium weight, cold rolled mild steel |
| 46 | S&F 125mm long butt hinges, medium weight, cold rolled mild steel |
| 47 | S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised |
| 48 | S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy. |
| 49 | S&F 200mm long aluminium anodised, barrel tower bolts of extruded section |
| 50 | M&L for 2nd class hardwood 30mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. devided in squares in plain, chamfered or rounded. mittered and rebated with sash bars and providing in windows, ventilators and stiles and rails etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (b). |
| 51 | S&F 75mm long butt hinges, medium weight, cold rolled mild steel |
| 52 | S&F 100mm long extruded aluminium alloy handles, fabricated type \"D\", anodised |
| 53 | S&F 100mm long aluminium anodised, barrel tower bolts of extruded section |
| 54 | S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5 sq. m in each pane |
| 55 | M&L for preparation of new wooden surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 56 | M&L for hardcore of gauge n exc. 63 mm of broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 57 | M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40 mm graded crushedstone aggregate in plinth protection including provision of necessary form work finishing the exposed surface even and smooth complete all as specified. |
| 58 | S & F rotational moulded polythene, three layers, water storage tank 2000Ltrs capacity, closed top, cylindrical, hoisted and fixed in position including minor repairing &20mmflot ball brass valves high pressure with polythene float and flynut complete,Aluminium rod & high-density plastic ball screwed for iron pipe complete all as specified and dirtected by Engr-in-Charge . |
| 59 | S&F 25mm dia nipple suitable for HDPE water tank. (Minimum weight 25mm- 65gms) |
| 60 | S&F 25mm bore Unions. brass to connect iron to polyethylene |
| 61 | S&F 15mm dia 3-layer PP-R ( Polylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc., complete all as specified and directed by Engr-in-Charge. |
| 62 | S&F 20mm dia 3-layer PP-R ( Polylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc., complete all as specified and directed by Engr-in-Charge. |
| 63 | S&F 25mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule |
| 64 | S&F Bib taps 15mm bore, chromium plated cost copper alloy with crutch or butterfly handle, screwed down screwed for brass ferrule |
| 65 | Rolling and consolidating formation surfaces in cutting using hand roller 0.2 to 0.5 tonne complete all as specified and as directed |
| 66 | M&L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in flooring and surface, finished rough all as specified and as directed. |
| 67 | M&L for 25 mm thick sand filling (crushed sand) under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge. |
| 68 | M&L for P.C.C. 1:5:10 type E-2 using 40 mm graded crushed stone aggregates as in flooring, PCC path, sub base,plinth protection and surface rough finished. |
| 69 | M&L for Machine pressed precast conctete interlocking paver block 80mm thick any shape and sizeconfirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment complete all as specified and directed by Engr-n-Charge. |
| 70 | M&L for construction of stone masonary valve pit chamber of size 110cm x 110cm x 110 cm (internal dimension) including all necessary excavation and earth work in hard/dense soil and disposal of surplus soil to a distance not exceeding 50 meters & depositing the same as directed including PCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement mortor 1:4 rendering 15 mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externaly as the work proceeds in the same mortar as of stone masonary including mild steel frame (made out of angle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with hinges angle iron flat as required at site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint and all other relevant work complete. |
| 71 | M&L for stone masonry walling of random rubble, brought upto coursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4 , and pointing flush the surfaces in centract with earth in the same mortar as the work proceeds including providing necessory weep holes at 2 mtr center to center complete all as specified and directed by Engr-in-Charge. |
| 72 | M&L for Precast reinforced cement concrete, type B-1,1:2:4(using 20mm graded crushed stone aggreagate)as inmanhole/drain cover set in cement mortor 1:4 , including necessory form work complete all as specified and directed by Engr-in-Charge. |
| 73 | Sch \"A\" Part-II E/M & W/S work:-M&L for point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5 sqmm copper conductor cable unsheathed as earth continuity cable including closed recessed wooden terminal boxes of suitable size made of 2nd class hard wood for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet top cover complete all as specified for the following:- Make of cable: Finolex/Polycab/Havells/Plaza.(a)One light /fan/bell point/buzzer point exhaust fan controlled by one nos, one way 5/6 Amps switch. |
| 74 | One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size |
| 75 | One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size |
| 76 | All as per srl item No 42 here-in-before but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable. |
| 77 | S&F switch socket combination, flush type 2 in 1, 3 pin, 5 and 15 Amp complete all as specified and directed by Engr-in-Charge. |
| 78 | S&F switch socket combination, flush type 2 in 1, 3 pin, 5 Amp complete all as specified and directed by Engr-in-Charge. |
| 79 | S&F Socket outlet multipurpose 3 pin, 5A, and 2 pin 6A flush type |
| 80 | S&F Switch piano, flush type single pole, one way 6 Amp |
| 81 | S&F Ceiling rose, 3 terminal PVC/polycarbonate, isolated body |
| 82 | S&F wall mounted LED lights fitting 1x 20W, 4 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 83 | S&F LED lights fitting indoor type 1x 10W, 2 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 84 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm |
| 85 | S&F in replacement pressed sheet metal enclosure double door SPN distribution board,8 way suitable for MCB\"s fitted with bus bar rated 200amps, neutrallink , earth bar and din rail suitable for use on 240 Volt, 50Hz . |
| 86 | S&F MCB TPN 32 Amp 415 volt AC with 10KA breaking capacity of \"C\" series in distribution boards all as specified and directed. |
| 87 | S&F MCB SPN 32 Amp 240 volt AC with 10KA breaking capacity of \"C\" series in distribution boards all as specified and directed. |
| 88 | S&Fin repair MCB SP 6-32 Amp 240 volt AC with 10KA breaking capacity of \"C\" series in distribution boards all as specified and directed. |
| 89 | Supply, laying and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 35 sq. mm 3.5 core complete all as specified |
| 90 | Supply, laying and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 50 sq. mm 3.5 core complete all as specified |
| 91 | S&F 1100 volts grade heavy duty 4 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm suspension complete all as specified. |
| 92 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 93 | M&L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt,connected to galvanized earh lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result complete including taking out of existing earthing all as specified. |
| 94 | Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes, laying of cable etc and not exceeding 10 sqm on plan for manholes etc and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge. |
| 95 | Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified. |
| 96 | Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed |
| 97 | Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I.(Note:-Punned thickness shall be measured and paid) |
| 98 | Supplying and laying reinforced precast concrete cable cover, class LV, Type I, flat, size 250 mm x 150mm x 40mm laid dry over electric cable for protection,complete all as specified and directed by the Engr-in-Charge. |
| 99 | S&F and installation, testing, and commissioning of submersible pump set 5 HP Horizantal type, openwell, electric driven 3 phase complete all as specified and directed. |
| 100 | S&F Automatic star-delta motor starter in sheet metal enclosure type ML suitable for 3 phase electric motor of capacity 5 HP, 3 phase 415V with relay range 16-25 Amps- 01 Nos |
| 101 | S&F pipe galvanized, \"Medium grade\" including fittings 80 mm dia all as directed by Engineer-in-Charge. |
| 102 | S&F sluice valve, flanged of class 1.6 PN complete of size 80 mm ( 3\") dia including cutting of exiting pipe all as directed by Engineer-in-Charge. |
| 103 | M&L for two coats of air draying algae, fungal growth resistant and anti corrision paint for holding drinking water.(Note:-Paint should be approved by AGE(I) from approved make) |