Tender For Repair And Maintenance Of Certain Internal Electrical Fittings And Fixtures Of Kwh Meters, Solar Water Heaters And Repair/ Replacement Of Wall Mounted Lt Dbs Metering Cubicals, Submain Wirings And Other Connected Items At Cme, kirkee-Maharashtra

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Certain Internal Electrical Fittings And Fixtures Of Kwh Meters, Solar Water Heaters And Repair/ Replacement Of Wall Mounted Lt Dbs Metering Cubicals, Submain Wirings And Other Connected Items At Cme. Submission Date for this Tender is 22-12-2022. Coats and Jackets Tenders in kirkee Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

34995386
Corrigendum : Tender For Repair And Maintenance Of Certain Internal Electrical Fittings And Fixtures Of Kwh Meters, Solar Water Heaters And Repair/ Replacement Of Wall Mounted Lt Dbs Metering Cubicals, Submain Wirings And Other Connected Items At Cme
Open Tender
Indian
Maharashtra
kirkee
22-12-2022

Tender Details

Tender For Repair And Maintenance Of Certain Internal Electrical Fittings And Fixtures Of Kwh Meters, Solar Water Heaters And Repair / Replacement Of Wall Mounted Lt Dbs Metering Cubicals, Submain Wirings And Other Connected Items At Cme- M & L For Servicing Solar Water Heater Of 100 / 200 / 400 / 500 Lpd Capacity ( Flat Plate Collector / Tube Collector ) By Removing The Flange Plates, Cleaning The Collectors Internally& Externally By Using Descaling Solution, Removing The Blockages In The Collectors Complete And Refixing The Flange Plates, Recharging The Water In Recharge Tank Testing For Satisfactory Function All As Specified And Directed. 2 S & F Heating Element 25Mm To 32Mm Dia, Isi Marked For Solar Water Heating Plant Of Capacity 3 Kwall As Specified And Directed By Engr In Charge. 3 S & F Flange Plates Of Size 25 Mm Dia Suitable For Flat Plate Collectors Including Taking Down Old Unseviceable Flange Plate All As Specified And Directed. 4 S & F Thermostat For Solar Water Heating Plant Of 100 / 200 / 400 / 500 Lpd Of Suitable Size And Ratings Etc Complete All As Specified And Directed. 5 S & F Flexible Heat Resistance Rubber Pipe ( From Inter Connect Plate Collector To Hot Water Tank ) Of Size 25 Mm To 32 Mm Dia Etc With Fixing Clamp Etc Complete All As Specified And Directed. 6 M & L For Repairs To Storage Type Elect. Water Heater ( Geyser ) Of Storage Capacity 25 / 35 / 50 Ltrs Of Any Make Comprisingof The Following Tasks At Different Locations As Directed:- ( A ) Inspection, Taking Down, Opening ( Dismantling ) Descaling, Brushing, Cleaning Of Storage Tank And Painting Internally With One Coat Of Proprietary Bituminous Compositionnot Liable To Impart Test Or Otherwise Contaminate The Water. ( B ) Replacement / Repair Of Neon Lamp / Indicatorlamp. ( C ) Replacement Of The Rubber / Pvc Gasket To Ensure Water Tightness. ( D ) Testing Of Geysers After Repairs. 7 Supply Only Thermostat Complete With Manually Temperture Settingknob Extra Long ( 11 Inches ) Isi Marked Suitable For Geysers 25 Litres To 50 Litres Capacity 8 S & F Hot / Cold Water Flexible Hose Pipe 12 / 16Mm Dia And 450 To 900Mm Long Heavy Duty Covered With Metal Wires Heat Resistence With Both Ends Pvc Hexagonal Check Nut With Washer To Fixed On 15Mm Dia Gi Pipe All As Specified And Directed. 9 Supply Only Heating Element Upto 2 Kw As Required At Site Including Rubber Washers ( Isi Marked ) Completeall As Specified And Directed. 10 Decarbonizing Ofindoor Mcb / Meter Boxany Type Removing Unserviceable Mcbs, Burnt Connecting Wires, Replacing Burnt, Damaged Wires Of Any Size, Welding Of Hinges Including Welding Using Extra Sheetsreplace Burnt Thimbles Of Existing Size , Dismantling The Existing Connected Cables / Wires And Re-Connecting The Same Cables / Wires Complete All As Specified And Directedby Engr -In- Charge. Note : ( I ) Mcb Will Be Measured & Paid Separately As Supply Only. ( Ii ) Necessary Ms Sheet And Welding Incuding Sealing The Meter With Sealing Lead / Pvc Seal All Are Inclusive Of Quoted Rate. ( Iii ) Required Size Ofcopper Cable For Connecting Mcbs And Meters Are Including Quoted Rate. 11 Labour Only For Attending Arman Complaints Received Through Online Media By Deploying Necessary Skilled Tradesman With Helper As Required At Site On Working Hours From0830 Hrs To 1730 Hrs On All Working Daysat Md Accn Area, Cme Kirkeenote: - ( I ) The Complaints Will Be Entered In Complaint Slip By Je E / M Mcm. ( Ii ) The Complaint Slip Should Be Returned To Je E / M On Completion Of The Work With Stores Consumed. ( Iii ) Any Delay In Attending The Complaints For More Than 03 Days, A Penalty Of Rs 50 / - Per Complaint Will Be Adhered To The Contractor. ( Iv ) The Details Of Stores Consumed, Complaint Slip Are To Be Produced During The Rar Bills. ( V ) T & P, Minor Spares Like Nuts, Bolts, Screws, Washers Insulation Tape Etc Required For Attending The Complaints Shall Be Provided By The Contractor And The Rate For The Same Is Deemed To Be Included In The Rate Quoted. 12 M & L For Repair And Replace Of Unserviceable Led Driver Suitable For 36 / 40 Watt Led Panel Light Fitting 2 X 2 Size On Siteall As Specified And Directed By Engr-In-Charge. 13 Taking Down Old Conventional Kwh Meter Deposited To Mes Store Yard And Supply & Fix New Tamper Proof Ac Three Phasestatic Energy Meter Of Accuracy Class 1.0, 240 V, 50 Hz With Bakelite Lcd Display Of Rating 10 - 60 A, ( Measures And Display Kwh , Voltage, Current, Load, Pf ) All As Specified And Directedby Engr-In-Charge. Make: Cat Part Nowm301bc7d10 Of L&T Or Equivalent In Hpl / Benlo / Schneider 14 Taking Down Old Conventional Kwh Meter Deposited To Mes Store Yard And Supply & Fix New Tamper Proof Ac Single Phasestatic Energy Meter Of Accuracy Class 1.0, 240 V, 50 Hz With Bakelite Lcd Display Of Rating 10 - 60 A, ( Measures And Display Kwh , Voltage, Current, Load, Pf ) All As Specified And Directedby Engr-In-Charge. Make: Cat Part Nowm101bc7dl0 Of L&T Or Equivalent In Hpl / Benlo / Schneider 15 Supply And Replace, Rubber Yoke, Ms Clamps, Bolts Nuts With Split Pin Suitable For Ceiling Fan 1200 / 1400 Mm Sweep Complete All As Specified And As Directed By Engr-In-Charge. 16 M & L Capacitor 2.5 Mfd For Ceiling Fan All As Specified And As Directed By Engr-In-Charge. 17 M & L For Painting Of Ceiling Fans Complete, In Situ With Synthetic Enamel Paint By Spraying Including Filling Cavities With Filler, One Coat After Cleaning All Dust Etc. All As Specified And As Directed. 18 Taking Downof Ceiling Fandismantling Blades From Fan And Deposited To Mes Store Yard For Repair And Collect Repaired / New Ceiling From Store And Hangingthe Same Complete All As Specified And Directed By Engr In Charge. 19 M&L In Replacement Of Pvc Rectangular Boards Closed Recessed Of Size 100 X 100 X 50Mm Complete All As Specified And Directed. 20 M&L In Replacement Of Pvc Rectangular Boards Closed Recessed Of Size 175 X 100 X 50Mm Complete All As Specified And Directed. 21 M&L In Replacement Of Pvc Rectangular Boards Closed Recessed Of Size 200 X 150 X 50Mm Complete All As Specified And Directed. 22 M&L In Replacement Of Pvc Rectangular Boards Closed Recessed Of Size 250 X 200 X 50Mm Complete All As Specified And Directed. 23 M&L In Replacement Of Hylam White 3 Mm Electrical Switch Board 24 M&L In Replacement Of Led Lamp 9 Watt Complete All As Specified And Directed. Make : Cat Part No Lhldeuebml8r009 Of Havells / Bajajsyska 25 S&F In Replacement Recess Cum Surface Panel Round Slim 18 Watt 6500 K Complete All As Specified And Directed.Make: Cat Part No Edgeproneorddlr18wled840s / Crompton / Bajaj 26 S & F Mccb 4 Pole 415V 63 Amps 16 Ka Incl Taking Down Old Unserviceable One. 27 S & F Mccb 4 Pole 415V 125 Amps 16 Ka Incl Taking Down Old Unserviceable One. 28 S & F Mccb 4 Pole 415V 160 Amps 36 Ka Incl Taking Down Old Unserviceable One Complete All As Specified And Directed. 29 S & F Mccb 4 Pole 415V 200 Amps 36 Ka Incl Taking Down Old Unserviceable One Complete All As Specified And Directed. 30 S & F Mccb 4 Pole 415V 250 Amps 36 Ka Incl Taking Down Old Unserviceable One Complete All As Specified And Directed. 31 S&F In Replacement Modular Single Phase Motor Starter For Ac With Green And Red Button Complete All As Specified And Directed. Make : Cat Part No Msbe20-25 Of Benlo / Havells / Anchor 32 S&F In Replacement Modular 32 Amps Dp Swtich Without Fuse Complete All As Specified And Directed. Make : Cat Part No Psbedp20-25 Of Benlo / Havells / Anchor 33 Taking Down Carefully Copper / Aluminium Point Wiring ( Light, Fan, Bell, Socket Or Power ) Complete, Including Fixture And Fittings Such As Switches, Ceiling Rose, Pendents, Regulators, Sockets, Light Fittings Etc Removing Materials To Store For Keeping In Safe Custody Or For Taking Creditand Making Good Disturbed Surfaces Of Walls, Floors, Etc . Credit For Above Items Should Be Made As Per Conditions Separately. 34 M&L For Point Wiring With Frlsh Cable 1.5 Sqmm Pvc Insulated ( Red For Phase And Black For Neutral ) Unsheathed, Multi Stranded Copper Conductor 1100 Volt Grade In And Incl Not Less Than 2Mm Thick Pvc Casing / Capingwith All Accessories And 1.50 Sqmm Green In Colour Pvc Copper Conductor Cable For Earth Continuity Connected To Common Earth Dolly Inclpvc Box Surface / Flush Type With Pvc Sheet For Mounting Fittings Such As Switches, Sockets, Fan Regulators, Etc Complete All As Specified And Directed For One Light / Fan / Bell Point Controlled By One Switch & Making Goodto Disturbed Surface Of Wall Etc For The Following :- 35 One Light Point Controlled By One Switch 36 One Fan / Exhaust Fan Point Controlled By One Switch And Regulator 37 Socket Outlet, Three Pin 5 Amps On The Same Board 38 Socket Outlet, Three Pin, 5 Amp, Independent 39 All As Per Item No.34 Above, But With 2.5 Sqmm Cable And 2.5 Sqmm For Earth Continuityfor Multipin 15 Amps Socket Outlet Flush Type On Independent Board. 40 Material & Labour Forpoint Wiring With 1.5 Sq.Mm Nominal Cross Sectional Area, Single Core, 1100 Volts Grade, Multi Stranded, Frlshpvc Insulated, Unsheathed Copper Conductor Cable In And Including Pvc Concealed Conduit Of 20 Mm Dia Or Higher, Medium Grade Complete With And Including All Pvc Conduit Accessories / Fittings, Brass Screws, Washers Etc, Sunk Zinc Coated Pressed Steel Terminal Boxes Including All Cutting Holes In Or Throughwalls, Making Good To Walls, Ceiling Etc Including Two Coats Of White / Colour Washing / Distempering Etc To The Disturbed Surfaces To Match The Existing With 3Mm Thick Plastic Laminated Sheet Top Cover Concealed In Wall With And Including Continuous Earth Wire Of Size 1.5 Sqmm Nominal Cross Sectional Area, Single Core, Pvc Insulated Stranded Copper Conductor Cable, Unsheathed And Connected To Common Earth And Earth Dolly Complete All As Specified And Directed For The Followings :- 41 One Light Point Controlled By One Switch 42 One Fan / Exhaust Fan Point Controlled By One Switch And Regulator 43 Socket Outlet, Three Pin 5 Amps On The Same Board 44 Socket Outlet, Three Pin, 5 Amp, Independent 45 All As Per Item No.36 Above, But With 2.5 Sqmm Cable And 2.5 Sqmm For Earth Continuityfor Multipin 15 Amps Socket Outlet Flush Type On Independent Board. 46 S & F Switch Piano, Flush Type, Single Pole One Way 5 Amps Complete All As Specified And Directed. 47 S & F Switch Piano, Flush Type, Single Pole One Way15 Ampscomplete All As Specified And Directed. 48 S & F Bell Pushflush Type Single Pole One Way 5 Ampscomplete All As Specified And Directed. 49 S & Fsocket Outlet 2 In 1, 5 Pin, 5 Amps Flush Typecomplete All As Specified And Directed. 50 S & Fsocket Outlet 5 In 1, 5 Pin, 15 Amps Flush Typecomplete All As Specified And Directed. 51 S & F Switch Socket Combination 5 In 1, 5 And 15 Amp Flush Typecomplete All As Specified And Directed. 52 S & F Ceiling Rose, 3 Terminal Pvc / Polycarbonate Isolated Body, Surface Bakelite 65 X 50 Mm, 3 Terminal Incl Pvc Square Blockcomplete All As Specified And Directed. 53 S & Flamp Holder, Pvc / Polycarbonate Type With Back Plate Suitable For Batten Fitting Incl Pvc Square Blockcomplete All As Specified And Directed. 54 S & F Stepped Type Electronic Fan Regulator Flush Typeon The Existing Phenolic Laminated Sheetcomplete All As Specified And Directed. 55 S & F In Replacemnet Call Bell Ding Dong Ac, 230 Volts, Single Polecomplete All As Specified And Directed. 56 S&F Switch Modular, One Way 6 Amps, 1 Module With Suitable Plate And Cover Complete All As Specified And Directed. 57 S&Fswitch Modular One Way 16 Amps, 1 Module With Suitable Plate And Cover Complete As Per Existing Make And Model All As Specified And Directed. 58 S&Fsocket Modular 6A, 2 / 3 Pin Combined 2 Module With Suitable Plate And Covercomplete As Per Exisisting Make And Model All As Specified And Directed. 59 S&F Socket Modular 6A / 16A, 2 / 3 Pin Combined 2 Module With Suitable Plate And Cover Complete As Per Existing Make And Model All As Specified And Directed. 60 S&F Modular Fan Regulator Step Type 120W, 2 Module With Suitable Plate And Cover Complete As Per Existing Make And Model All As Specified And Directed. 61 S&F Modular Bell Push 6 Amps 1 Module With Suitable Plate And Cover Complete As Per Existing Make And Model All As Specified And Directed. 62 S&Fwhite Cover Plate With Frame 1 Module Complete As Per Existing Make And Model All As Specified And Directed. 63 S&F White Cover Plate With Frame 2 Module Complete As Per Existing Make And Model All As Specified And Directed. 64 S&F White Cover Plate With Frame 3 Modulecomplete As Per Existing Make And Model All As Specified And Directed. 65 S&F White Cover Plate With Frame 4 Module Complete As Per Existing Make And Model All As Specified And Directed. 66 S&F White Cover Plate With Frame 6 Module Complete As Per Existing Make And Model All As Specified And Directed. 67 S&F White Cover Plate With Frame 8 Module Complete As Per Existing Make And Model All As Specified And Directed. 68 S&F Decorative Ultra Slim With Polycarbonate Housing With High Lumen Output Environmental Friendly, Energy Efficient Ready To Use Pack Surface And Wall Mounted Led Batten ( Led Tube Light Fitting Complete 20W ) With Integrated Electronic Driver And 02 No Pvc Square Blocks Incl Taking Down Old Unsv Fitting.Make : Cat Part No Lumilinebs20wled830spcwh Of Havells Or Equivalent Of Philips / Bajaj / Crompton Greaves / Wipro / Shakti / Halonix / Jaquar. 69 S&F Decorative Ultra Slim With Polycarbonate Housing With High Lumen Output Environmental Friendly, Energy Efficient Ready To Use Pack Surface And Wall Mounted Led Batten ( Led Tube Light Fitting Complete 10W ) With Integrated Electronic Driver And 02 No Pvc Square Blocks Incl Taking Down Old Unsv Fitting. Make : Cat Part No Lumilinebs10wled865spcwh Of Havells Or Equivalent Of Philips / Bajaj / Crompton Greaves / Wipro / Shakti / Halonix / Jaquar / C & S / Bentec India Ltd. / Luker. 70 S&Fnew Generation Energy Saving Led Bulk Head Fitting 10 Watt Made Up Of Poly Carbonate Housing With Diffuser Incl Taking Down Old Unsv Fitting.Make : Cat Part No Hexaft10wled857ssymopc Of Havells Or Equivalent Of Philips / Bajaj / Crompton Greaves / Wipro / Shakti / Halonix / Jaquar / C & S / Bentec India Ltd. / Luker. 71 S&F Led Building Security Light Fitting 25 Watt , Energy Saving And Environmental Friendly Long Life Led Fitting Made Up Of Pressure Die Cast Aluminium Housing With Acrylic Cover As Diffuser With Ip 66 Protection Including Suitable Size Bracket Incl Taking Down Old Unsv One. Make : Cat Part No Endurasundownsl25wled765pasybopcihd Of Havells Or Equivalent Of Philips / Bajaj / Crompton Greaves / Wipro / Shakti / Halonix / Jaquar / C & S / Bentec India Ltd. / Luker. 72 S&F Decorative Wall Light Fittings ( Bracket Light ) , City 3 Made Up Of Polycarbonate Suitable For 10 Watt Led Lamp Incl Led Lamp Incl Taking Down Old Unsv One.Make : Cat Part No Lhdl06160099 Of Havells Or Equivalent Of Philips / Bajaj / Crompton Greaves / Wipro / Shakti / Halonix / Jaquar / C & S / Bentec India Ltd. / Luker. 73 S&F In Replacementip65 New Generation, Post-Top 35 Watt, Energy Saving, Environmental Friendly, Long Life Aesthetically Designed With Symmetrical Light Distribution, Spun Aluminium Landscape Luminaire With High Power Leds As Light Source.Make : Cat Part No Rubypt35wled830psymtopc Of Havells Or Equivalent Of Philips / Bajaj / Crompton Greaves / Wipro / Shakti / Halonix / Jaquar / C & S / Bentec India Ltd. / Luker. 74 Supply And Fixing Energy Saving, Environmental Friendly, Long Life, Exclusive Innovative Die-Cast Aluminium Flood Light 30 Watt With High Power Leds As Light Source, Suitable For Highlighting Architectural Features Or Area Lighting. Also Suitable To Rough Services / Installations. ( Note - The Contractor Is Responsible To Arrangesuitable Height Of Ladder For Replacement Of Fitting ) . Make-Cat Part No Jetaquantoplusflp30wled757sylens Of Havells Or Equivalent Of Philips / Bajaj / Crompton Greaves / Wipro / Shakti / Halonix / Jaquar / C & S / Bentec India Ltd. / Luker. 75 S&F Enclosure, Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb 20 Amps, 240 Volt Incl Taking Down Old Unsv One. 76 S&F Mcb Distribution Board Double Door Spn 240 Volts 8 Way With 200 Amps Rated Bus Bar And Making Good To Disturbed Surfaces Of Floors Walls Etc Incl Taking Down Old Unserviceable One. 77 S&F Mcb Distribution Board Double Door240volts 4 Way With 200 Amps Rated Bus Bar And Making Good To Disturbed Surfaces Of Floors Walls Incl Taking Down Old Unserviceable One. 78 S & F Mcb Sp 6 To 32 Amps, 230 V Ac Incl Taking Down Old Unserviceable One Complete All As Specified And Directed. 79 S & Fmcb Spn 40 Amps, 230 V, Ac Incl Taking Down Old Unserviceable One Complete All As Specified And Directed. 80 S & F Mcb Spn 63 Amps, 230 V, Ac Incl Taking Down Old Unserviceable One Complete All As Specificed And Directed. 81 S & Fmcb Tpn 63 Amps, 415 V, Ac Incl Taking Down Old Unserviceable One Complete All As Specified And Directed. 82 Supplying And Fixing In Repairs 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Multistranded Conductor Of Size 10 Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections One Twin Core Cable Flat Or Circular 83 Supplying And Fixing In Repairs 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Multistranded Conductor Of Size 6 Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections One Twin Core Cable Flat Or Circular 84 Supplying And Fixing In Repairs 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Multistranded Conductor Of Size 4 Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections One Twin Core Cable Flat Or Circular 85 S&F Led Panel 2 Feet X 2 Feet Size 36 Wattt Glare Free Symmetrical Including Driver And Taking Down Old Unsv One Complete All As Specified And Directed.Make : Cat Part No Venusneohe4x1plr36wled857s Of Havells Or Equivalent Of Philips / Bajaj / Crompton Greaves / Wipro / Shakti / Halonix / Jaquar / C & S / Bentec India Ltd. / Luker. 86 Supply And Fix In Repairs Mushroom ( Prismatic ) Decorative Gate Light Made Up Of High Grade Unbreakable Polycarbonate Material Suitable For Retrofit Led Lamp B22 Base. Make : Cat Part No Lhfxamn1tn6f035 Of Havells Or Equivalent Of Philips / Bajaj / Crompton Greaves / Wipro / Shakti / Halonix / Jaquar / C & S / Bentec India Ltd. / Luker.. 87 Supply, Install In Replacement Metering Cubical Board Wall Mounted Self Supporting Compartmentalised Design Of Suitable Size Cpri Approved To Accommodate The Lt Switch Gears & Other Accessories Suitable For 415 Volt 3 Phase 4 Wire Supply Made Out Of 2.0Mm Crca Sheet Powder Coated Having Gasketed Front Two Hinged Doors With Locking Arrangement Including Having Provision For Glass / Fibre Section With Rubber Gasket To Watch Meters Reading Without Opening The Panel Door Including Bottom And Top Detachable Gland Plate Complete With Suitable Size Of Rust Proof Nuts Bolts And Washers Etc Complete With Mounting Accessories Including The Following :- 88 Four Aluminumbus Bar 200A Mounted On Epoxy Insulators Provided With Rust Proof Nuts Bolts And Washer. 89 Mccb 4 Pole 63 Amps 25 Ka-1 No. 90 Mcb Spn 32 Amps -04 Nos 91 Mcb Sp 6-32 Amps - 01 No 92 Space For Mounting Of Tamper Proof Electric Meter 0-60 Amps -04 Nos. 93 Led Indicating Lamp-3 Nos ( Ryb ) 94 Ammeter 0-200 Amps With Ct Coil And Selector Switch -01 Set 95 Voltmeter 0-500Volt With Selector Swtich-01 No. 96 Note:-Rates For Taking Down And Refixing Of Energy Meters Deemed To Be Included In The Quoted Rate. Rates For Other Minor Accessories Such As Nut, Bolts, Removing And Jointing Of Cable With Lugs Etc Shall Be Included In The Quoted Rate Of This Item. 97 Material & Labour For Replacement Of Old Unsv Mccb Of Any Type / Capacity With New Mccb Fp 400 Amps 415 Ac, 50 Hz, 50 Ka Thermal Magnetic Release Adjustable Type Complete All As Directed. Make : Indoasian / L&T / Legrand 98 M & L For Preparation Of Old Painted Surfaces Of Lt Panel Or Street Light Panel / Metering Cubicalscovered By Dust And Other Depositedmaterials By Cleaning Frompanelof Sizeincluding Repair Of Panel Door, Hinged Nutbolts, Clamp Etc And Painting With One Coat Of Synthetic Enamel Paint Of Existing Colour Complete All As Specified And Directed.Note :Size Of Panel May Be Differ No Extra Shall Be Paid For Painting Of Extra Size Panel As Specified In Item. 99 Supply And Fixing In Replacement Three Pole Contactor Current Rating 70 A General Use 10A, 415Vwith Coil Make L&T Model Mnx 70 Three Pole Contactor Complete. Make L&T Cat Part No Cs97076 / Legrand / Schneider 100 Supply And Fixing In Replacement Mnx 50 To 80 Spare Coil For Three Pole Contactor Complete All As Specidired And Directed.Make : L&T Cat Part No Cs96318 / Legrand / Scheider 101 Supply And Fixing In Replacementdigital Timer Switch With Inbuilt Backup Current Capacity 16 Amps Operated On 415 Volts Ac 50Hz Complete All As Specified And Directed. Make: Indoasian Cat Part No. Tda43111 / Legrand 102 Supply And Fixing In Replacementexisting Aluminiumbus Barrectangular 200 To 400 Amps Full For Phase And Half For Neutral And Interconnection Of Mccbs To Bus Bar Mounted On Epoxy Insulators Including Nut, Bolts With Colour Coding Pvc Sleeves. Note : Size Of Bus Bar Should Be As Per Existing Or As Directed By Engr-In-Charge. 103 Supply And Fixing In Replacement Of Aluminiumlugs Of Size 16 Sqmm To 50 Sqmm And Tightening Of All Connecting Points, Cable Connection Complete All As Specified And Directed. 104 Supply And Fixing In Replacement Of Aluminiumlugs Of Size 70 Sqmm To 120 Sqmm And Tightening Of All Connecting Points, Cable Connection Complete All As Specified And Directed By Engineer-In- Charge 105 M&L For Sub Main Wiring With Two Run Of10 Sqmm Single Core Multi Stranded Pvc Insulated And Unsheathed Copper Conductor ( Red For Phase And Black For Neutral ) Of Grade 1100 Volt Frlsh Cable In And Including 1100 Volt Electrical Grade Pvc Conduitof Desired Colour Not Less Than1.2 Mm Thick And 25 Mm Wide& 10 Sqmm Copper Conductor Cable Pvc Unsheathed Green Coloured For Earthing With Complete Accessories Duly Connected With Earth Dolly Complete All As Specified And As Directed Incl Taking Down Old Unserviceable One. 106 All As Per Item No.88 Above, But Size 10 Sqmm Four Runs Andwith One Run 10 Sqmm Frlsh Copper Wire For Earth Continuity. 107 All As Per Item No.88 Above, But Size 6 Sqmm Four Runs Andwith One Run 6.0 Sqmm Frlsh Copper Wire For Earth Continuity. 108 All As Per Item No.88 Above, But Size 6 Sqmm Two Runs Andwith One Run 6.0 Sqmm Frlsh Copper Wire For Earth Continuity. 109 All As Per Item No.88 Above, But Size 4 Sqmm Four Runs Andwith One Run 4.0 Sqmm Frlsh Copper Wire For Earth Continuity. 110 All As Per Item No.88 Above, But Size 4 Sqmm Two Runs Andwith One Run 4.0 Sqmm Frlsh Copper Wire For Earth Continuity. 111 All As Per Item No.88 Above, But Size 2.5 Sqmm Two Runs Andwith One Run 2.5 Sqmm Frlsh Copper Wire For Earth Continuity. 112 M&L In Replacement Maintenance Free Grounding Solution Set Earthing Comprising Of Earthing Rod, Outer Pipe In Gi And Having Minimum Diameter Of 76Mm, 3M In Length And Inner Pipe To Have Minimum Diameter Of 32Mm, Both End Properly Welded To Make Them Airtight. Gi Terminal Size Of 100 X 50 X 6Mm With 2 Nos M8 Holes For Termination Area In Between Two Pipes Filled With Dry Type Chemical Powder Having High Conductivity And Make Sure No Air Pockets Are Left. Electrode Must Be Tested For Short Circuit Test Of Minimum 40 Ka At Cpri / Nabl. The Earthing Electrode Will Be Placed In The Ground After A Bore Is Drilled To The Depth Of 3.5 Mtr. The Bore Drilling Will Be Donewith The Help Of Pneumatic Boring Machine, 50 Kgs Bfc Will Be Placed In The Bore To Cover The Earthing Rod From All Sides. Bfc Will Be Poured In Slurry Form In Properly Mixed Condition. The Earth Pit Cover Square 300 X 300 X 240 Mm To Be Provided To Cover The Earth Pit And Shall Be Made Of Reinforced Frp And Should Be Capable Of Carrying The Weight Of 5 Tons. Make : U-Protecearthing / Shivangi Engineering Works ( Earth Sol-3 ) / Jef Techno Solution Pvt Ltd ( Jef Ecosafe ) 113 Note :- ( A ) Rates Of Boring 3.5 Mtr For Earth Electrode, Gi Strip 20 X 3 Mm & 40 Mm Dia Protection Pipe Upto 7.5 Mtr From Earth Electrode Is Deemed To Be Included In The Quoted Rate. ( B ) On Testing, After Completion, If The Earth Resistance <2 Ohms Is Not Obtained, Earthing Will Be Done Again At No Extra Cost Till The Desired Earth Resistance Is Obtained. ( C ) Test Certificate From The Oem Has To Be Produced By The Contractor For The Material Used In Earthing. 114 S&F Mcb Distribution Board Double Door Spn 240 Volts 12 Way With 200 Amps Rated Bus Bar And Making Good To Disturbed Surfaces Of Floors Walls Etc Incltaking Down Old Unserviceable One. 115 M & Lmcb Distribution Board Double Door 415 Volt, Tpn4-Way, Incl Taking Down Old Unserviceable 116 S&F Load Line Vertical Tpn Distribution Board 4 Way Including 1 Incommer Mccb Of 125 Amps 4 Pole Double Door Ip-43 Protection, Powder Coated, Ik08 With Provision Of Suitable Size Bus Bar And Cable Management Kit Complete Including Taking Down Old Unserviceable One All As Specified And Directed. 117 Supply, Laying And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) With Stranded Aluminium Conductor 1100 Volts Grade In Trenches / Passing Through Pipe / Fixing On Walls, Floors Etc Incl Using Suitable Clamp Of Cross Sectional Area4 Core 25 Sqmmin And Including Taking Out Old One All As Specified And Directed. 118 All As Per Item No.99 Above, But 3.5 Core 35 Sqmm 119 Excavation In Trenches Not Exc. 1.5M Wide And Not Exc. 1.5M Deepand Making Goodsurface For Laying / Removing Of Cable All As Specified And Directed By Engr In Charge As In 120 Soft / Loose Soil 121 Hard / Dense Soil 122 Returning, Filling In, Excavated Soil In Trenches, Including Watering And Well Ramming In Layers Not Exc. 25 Cm Complete All As Specified And Directed. 123 Removal Of Surplus Excavated Spoil To Distance Not Exc. 50Metre And Deposting Where Directed At A Level Not Exc. 1.5M Above The Starting Point Complete All As Specified And Directed. 124 Supply & Laying In Replacement Of Telerex Dwc ( Double Wall Corrugated ) Hdpe Pipe Isi Marked Of Outer Dia Of 50 Mm And Inner Dia 38 Mm Polythylene With Smooth Internal And Profiled External Surface For Non Pressure Under Ground Cableincl Couplers & Bends Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Dec-2022 Name of work Other 15-12-2022
2 08-Dec-2022 BOQ item No. 94, qty.350 and Name of work BOQ 15-12-2022
3 15-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 99980.0 /-
Tender Value
INR 49.99 Lakhs /-

BOQ Items

Name of Work:Repair & maint of certain internal electrical fittings & fixtures of KWh meters, solar water heaters and Repair, replacement of wall mounted LT DBs metering cubicals, submain wirings and other connected items at CME
Sl. No. Item Description
1M & L for servicing solar water heater of 100/200/400/500 LPD capacity(flat plate collector/tube collector) by removing the flange plates, cleaning the collectors internally& externally by using descaling solution, removing the blockages in the collectors complete and refixing the flange plates, recharging the water in recharge tank testing for satisfactory function all as specified and directed.
2S & F heating element 25mm to 32mm dia, ISI marked for solar water heating plant of capacity 3 KWall as specified and directed by Engr in charge.
3S & F flange plates of size 25 mm dia suitable for flat plate collectors including taking down old unseviceable flange plate all as specified and directed.
4S & F thermostat for solar water heating plant of 100/200/400/500 LPD of suitable size and ratings etc complete all as specified and directed.
5S & F flexible heat resistance rubber pipe (from inter connect plate collector to hot water tank) of size 25 mm to 32 mm dia etc with fixing clamp etc complete all as specified and directed.
6M & L for repairs to storage type elect. water heater(geyser) of storage capacity 25/35/50 ltrs of any make comprisingof the following tasks at different locations as directed:- (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank and painting internally with one coat of proprietary bituminous compositionnot liable to impart test or otherwise contaminate the water. (b) Replacement / repair of neon lamp / indicatorlamp. (c) Replacement of the rubber / PVC gasket to ensure water tightness. (d) Testing of geysers after repairs.
7Supply only thermostat complete with manually temperture settingknob extra long (11 inches) ISI marked suitable for geysers 25 litres to 50 litres capacity
8S & F Hot/Cold water flexible hose pipe 12/16mm dia and 450 to 900mm long heavy duty covered with metal wires heat resistence with both ends PVC hexagonal check nut with washer to fixed on 15mm dia GI pipe all as specified and directed.
9Supply only heating element upto 2 KW as required at site including rubber washers (ISI Marked) completeall as specified and directed.
10Decarbonizing ofindoor MCB / meter boxany type removing unserviceable MCBs, burnt connecting wires,replacing burnt, damaged wires of any size,welding of hinges including welding using extra sheetsreplace burnt thimbles of existing size , dismantling the existing connected cables/wires and re-connecting the same cables/wires complete all as specified and directedby Engr -in- charge. Note : (i) MCB will be measured & paid separately as supply only. (ii) necessary MS sheet and welding incuding sealing the meter with sealing Lead/PVC seal all are inclusive of quoted rate. (iii) Required size ofcopper cable for connecting MCBs and meters are including quoted rate.
11Labour only for attending Arman complaints received through online media by deploying necessary skilled tradesman with helper as required at site on working hours from0830 Hrs to 1730 hrs on all working daysat Md Accn Area, CME Kirkee Note: - (i) The complaints will be entered in complaint slip by JE E/M MCM. (ii) The complaint slip should be returned to JE E/M on completion of the work with stores consumed. (iii) Any delay in attending the complaints for more than 03 days, a penalty of Rs 50/- per complaint will be adhered to the contractor. (iv) The details of stores consumed, complaint slip are to be produced during the RAR bills. (v) T & P, Minor spares like nuts, bolts, screws, washers insulation tape etc required for attending the complaints shall be provided by the contractor and the rate for the same is deemed to be included in the rate quoted.
12M & L for repair and replace of unserviceable LED driver suitable for 36/40 watt LED panel light fitting 2 x 2 size on siteall as specified and directed by Engr-in-Charge.
13Taking down old conventional KWH meter deposited to MES Store yard and supply & fix new tamper proof AC three phasestatic energy meter of accuracy class 1.0, 240 V, 50 Hz with bakelite LCD display of rating 10 - 60 A, (measures and display KWH ,Voltage, Current, load,PF )all as specified and directedby Engr-in-charge. Make: cat part NoWM301BC7D10 of L&T or equivalent in HPL/Benlo/Schneider
14Taking down old conventional KWH meter deposited to MES Store yard and supply & fix new tamper proof AC single phasestatic energy meter of accuracy class 1.0, 240 V, 50 Hz with bakelite LCD display of rating 10 - 60 A, (measures and display KWH ,Voltage, Current, load,PF )all as specified and directedby Engr-in-charge. Make: cat part NoWM101BC7DL0 of L&T or equivalent in HPL/Benlo/Schneider
15Supply and replace, rubber yoke, MS Clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and as directed by Engr-in-charge.
16M & L capacitor 2.5 mfd for ceiling fan all as specified and as directed by Engr-in-Charge.
17M & L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. all as specified and as directed.
18Taking downof ceiling fandismantling blades from fan and deposited to MES store yard for repair and collect repaired/new ceiling from store and hangingthe same complete all as specified and directed by Engr In Charge.
19M&L in replacement of PVC rectangular boards closed recessed of size 100 x 100 x 50mm complete all as specified and directed.
20M&L in replacement of PVC rectangular boards closed recessed of size 175 x 100 x 50mm complete all as specified and directed.
21M&L in replacement of PVC rectangular boards closed recessed of size 200 x 150 x 50mm complete all as specified and directed.
22M&L in replacement of PVC rectangular boards closed recessed of size 250 x 200 x 50mm complete all as specified and directed.
23M&L in replacement of Hylam White 3 mm Electrical Switch Board
24M&L in replacement of LED lamp 9 watt complete all as specified and directed. Make : Cat part No LHLDEUEBML8R009 of Havells/BajajSyska
25S&F in replacement recess cum surface panel round Slim 18 watt 6500 K complete all as specified and directed.Make: Cat part No EDGEPRONEORDDLR18WLED840S/Crompton/Bajaj
26S & F MCCB 4 pole 415V 63 Amps 16 kA incl taking down old unserviceable one.
27S & F MCCB 4 pole 415V 125 Amps 16 kA incl taking down old unserviceable one.
28S & F MCCB 4 pole 415V 160 Amps 36 kA incl taking down old unserviceable one complete all as specified and directed.
29S & F MCCB 4 pole 415V 200 Amps 36 kA incl taking down old unserviceable one complete all as specified and directed.
30S & F MCCB 4 pole 415V 250 Amps 36 kA incl taking down old unserviceable one complete all as specified and directed.
31S&F in replacement modular single phase motor starter for AC with green and red button complete all as specified and directed. Make : Cat part No MSBE20-25 of Benlo/Havells/Anchor
32S&F in replacement modular 32 Amps DP swtich without fuse complete all as specified and directed. Make : Cat part No PSBEDP20-25 of Benlo/Havells/Anchor
33Taking down carefully copper/aluminium point wiring (light, fan,bell, socket or power) complete, including fixture and fittings such as switches, Ceiling rose,pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking creditand making good disturbed surfaces of walls, floors, etc . credit for above items should be made as per conditions separately.
34M&L for point wiring with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/capingwith all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly inclPVC box surface/ flush type with PVC sheet for mounting fittings such as switches, sockets, fan regulators,etc complete all as specified and directed for one light/fan /bell point controlled by one switch & making goodto disturbed surface of wall etc for the following :-
35One light point controlled by one switch
36One fan/exhaust fan point controlled by one switch and regulator
37Socket outlet, three pin 5 Amps on the same board
38Socket outlet, three pin, 5 Amp, independent
39All as per item No.34 above, but with 2.5 sqmm cable and 2.5 sqmm for earth continuityfor multipin 15 amps socket outlet flush type on independent board.
40Material & labour forpoint wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSHPVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunk zinc coated pressed steel terminal boxes including all cutting holes in or throughwalls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings :-
41One light point controlled by one switch
42One fan/exhaust fan point controlled by one switch and regulator
43Socket outlet, three pin 5 Amps on the same board
44Socket outlet, three pin, 5 Amp, independent
45All as per item No.36 above, but with 2.5 sqmm cable and 2.5 sqmm for earth continuityfor multipin 15 amps socket outlet flush type on independent board.
46S & F switch piano, flush type, single pole one way 5 amps complete all as specified and directed.
47S & F switch piano, flush type, single pole one way15 ampscomplete all as specified and directed.
48S & F bell pushflush type single pole one way 5 ampscomplete all as specified and directed.
49S & Fsocket outlet 2 in 1, 5 pin, 5 amps flush typecomplete all as specified and directed.
50S & Fsocket outlet 5 in 1, 5 pin, 15 amps flush typecomplete all as specified and directed.
51S & F switch socket combination 5 in 1, 5 and 15 Amp flush typecomplete all as specified and directed.
52S & F ceiling rose, 3 terminal PVC/polycarbonate isolated body, surface bakelite 65 x 50 mm, 3 terminal incl PVC square blockcomplete all as specified and directed.
53S & Flamp holder, PVC/polycarbonate type with back plate suitable for batten fitting incl PVC square blockcomplete all as specified and directed.
54S & F stepped type electronic fan regulator flush typeon the existing phenolic laminated sheetcomplete all as specified and directed.
55S & F in replacemnet Call bell ding dong AC, 230 Volts, single polecomplete all as specified and directed.
56S&F switch Modular, one way 6 amps, 1 module with suitable plate and cover complete all as specified and directed.
57S&Fswitch modular one way 16 amps, 1 module with suitable plate and cover complete as per existing make and model all as specified and directed.
58S&Fsocket modular 6A, 2/3 pin combined 2 module with suitable plate and covercomplete as per exisisting make and model all as specified and directed.
59S&F socket modular 6A/16A, 2/3 pin combined 2 module with suitable plate and cover complete as per existing make and model all as specified and directed.
60S&F modular fan regulator step type 120W, 2 module with suitable plate and cover complete as per existing make and model all as specified and directed.
61S&F modular bell push 6 Amps 1 module with suitable plate and cover complete as per existing make and model all as specified and directed.
62S&FWhite cover plate with frame 1 module complete as per existing make and model all as specified and directed.
63S&F White cover plate with frame 2 module complete as per existing make and model all as specified and directed.
64S&F White cover plate with frame 3 modulecomplete as per existing make and model all as specified and directed.
65S&F White cover plate with frame 4 module complete as per existing make and model all as specified and directed.
66S&F White cover plate with frame 6 module complete as per existing make and model all as specified and directed.
67S&F White cover plate with frame 8 module complete as per existing make and model all as specified and directed.
68S&F Decorative ultra slim with polycarbonate housing with high lumen output environmental friendly, energy efficient ready to use pack surface and wall mounted LED batten (LED tube light fitting complete 20W) with integrated electronic driver and 02 No PVC square blocks incl taking down old UNSV fitting. Make : Cat part No LUMILINEBS20WLED830SPCWH of Havells or equivalent of Philips/ Bajaj/ Crompton Greaves/ wipro/ Shakti/ Halonix/ Jaquar.
69S&F Decorative ultra slim with polycarbonate housing with high lumen output environmental friendly, energy efficient ready to use pack surface and wall mounted LED batten (LED tube light fitting complete 10W) with integrated electronic driver and 02 No PVC square blocks incl taking down old UNSV fitting. Make : Cat part No LUMILINEBS10WLED865SPCWH of Havells or equivalent of Philips/ Bajaj/ Crompton Greaves/ wipro/ Shakti/ Halonix/ Jaquar/ C & S/ Bentec India Ltd./ Luker.
70S&Fnew generation energy saving LED Bulk Head fitting 10 Watt made up of Poly carbonate housing with diffuser incl taking down old UNSV fitting.Make : Cat part No HEXAFT10WLED857SSYMOPC of Havells or equivalent of Philips/ Bajaj/ Crompton Greaves/ wipro/ Shakti/ Halonix/ Jaquar/ C & S/ Bentec India Ltd./ Luker.
71S&F LED building security light fitting 25 Watt , energy saving and environmental friendly long life LED fitting made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection including suitable size bracket incl taking down old UNSV one. Make : Cat part No ENDURASUNDOWNSL25WLED765PASYBOPCIHD of Havells or equivalent of Philips/ Bajaj/ Crompton Greaves/ wipro/ Shakti/ Halonix/ Jaquar/ C & S/ Bentec India Ltd./ Luker.
72S&F decorative wall light fittings (bracket light), CITY 3 made up of polycarbonate suitable for 10 watt LED lamp incl LED lamp incl taking down old UNSV one.Make : Cat part No LHDL06160099 of Havells or equivalent of Philips/ Bajaj/ Crompton Greaves/ wipro/ Shakti/ Halonix/ Jaquar/ C & S/ Bentec India Ltd./ Luker.
73S&F in replacementIP65 new generation, post-top 35 watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Make : Cat part No RUBYPT35WLED830PSYMTOPC of Havells or equivalent of Philips/ Bajaj/ Crompton Greaves/ wipro/ Shakti/ Halonix/ Jaquar/ C & S/ Bentec India Ltd./ Luker.
74Supply and fixing Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium flood light 30 watt with high power LEDs as light source, suitable for highlighting architectural features or Area Lighting. Also suitable to rough services/installations. (Note - The contractor is responsible to arrangesuitable height of ladder for replacement of fitting). Make-Cat part No JETAQUANTOPLUSFLP30WLED757SYLENS of Havells or equivalent of Philips/ Bajaj/ Crompton Greaves/ wipro/ Shakti/ Halonix/ Jaquar/ C & S/ Bentec India Ltd./ Luker.
75S&F enclosure, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps, 240 volt incl taking down old UNSV one.
76S&F MCB distribution board Double door SPN 240 volts 8 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc incl taking down old unserviceable one.
77S&F MCB distribution board double door240volts 4 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls incl taking down old unserviceable one.
78S & F MCB SP 6 to 32 Amps, 230 V AC incl taking down old unserviceable one complete all as specified and directed.
79S & FMCB SPN 40 Amps, 230 V, AC incl taking down old unserviceable one complete all as specified and directed.
80S & F MCB SPN 63 Amps, 230 V, AC incl taking down old unserviceable one complete all as specificed and directed.
81S & FMCB TPN 63 Amps, 415 V, AC incl taking down old unserviceable one complete all as specified and directed.
82Supplying and fixing in repairs 1100 volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular
83Supplying and fixing in repairs 1100 volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 6 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular
84Supplying and fixing in repairs 1100 volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 4 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular
85S&F LED panel 2 feet x 2 feet size 36 wattt glare free symmetrical including driver and taking down old UNSV one complete all as specified and directed. Make : Cat part No VENUSNEOHE4X1PLR36WLED857S of Havells or equivalent of Philips/ Bajaj/ Crompton Greaves/ wipro/ Shakti/ Halonix/ Jaquar/ C & S / Bentec India Ltd./ Luker.
86Supply and fix in repairs mushroom (PRISMATIC) Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base. Make : Cat part No LHFXAMN1TN6F035 of Havells or equivalent of Philips/ Bajaj/ Crompton Greaves/ wipro/ Shakti/ Halonix/ Jaquar/ C & S / Bentec India Ltd./ Luker..
87Supply, install in replacement metering cubical board wall mounted self supporting compartmentalised design of suitable size CPRI approved to accommodate the LT switch gears & other accessories suitable for 415 volt 3 phase 4 wire supply made out of 2.0mm CRCA sheet powder coated having gasketed front two hinged doors with locking arrangement including having provision for glass/fibre section with rubber gasket to watch meters reading without opening the panel door including bottom and top detachable gland plate complete with suitable size of rust proof nuts bolts and washers etc complete with mounting accessories including the following :-
88Four aluminumbus bar 200A mounted on epoxy insulators provided with rust proof nuts bolts and washer.
89MCCB 4 pole 63 Amps 25 KA-1 No.
90MCB SPN 32 Amps -04 Nos
91MCB SP 6-32 Amps - 01 No
92Space for mounting of tamper proof electric meter 0-60 amps -04 Nos.
93LED indicating lamp-3 Nos (RYB)
94Ammeter 0-200 Amps with CT coil and selector switch -01 set
95Voltmeter 0-500volt with selector swtich-01 No.
96Note:-Rates for taking down and refixing of energy meters deemed to be included in the quoted rate. Rates for other minor accessories such as nut, bolts, removing and jointing of cable with lugs etc shall be included in the quoted rate of this item.
97Material & Labour for replacement of old UNSV MCCB of any type/capacity with new MCCB FP 400 Amps 415 AC, 50 Hz, 50 kA thermal magnetic release adjustable type complete all as directed. Make : Indoasian /L&T/Legrand
98M & L for Preparation of old painted surfaces of LT Panel or Street light Panel/metering cubicalscovered by dust and other depositedmaterials by cleaning fromPanelof Sizeincluding repair of panel door, hinged nutbolts, clamp etc and painting with one coat of synthetic enamel paint of existing colour complete all as specified and directed. Note :Size of panel may be differ no extra shall be paid for painting of extra size panel as specified in item.
99Supply and fixing in replacement three pole Contactor current Rating 70 A General use 10A, 415Vwith coil Make L&T Model MNX 70 Three pole contactor complete. Make L&T cat part No CS97076/Legrand/schneider
100Supply and fixing in replacement MNX 50 to 80 spare coil for three pole Contactor complete all as specidired and directed.Make : L&T cat part No CS96318/Legrand/scheider
101Supply and fixing in replacementDigital timer switch with inbuilt backup current capacity 16 Amps operated on 415 volts AC 50Hz complete all as specified and directed. Make: Indoasian cat part No. TDA43111/ Legrand
102Supply and fixing in replacementexisting Aluminiumbus barrectangular 200 to 400 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators including nut, bolts with colour coding PVC sleeves. Note : Size of bus bar should be as per existing or as directed by Engr-in-Charge.
103Supply and fixing in replacement of Aluminiumlugs of size 16 Sqmm to 50 Sqmm and tightening of all connecting points, cable connection complete all as specified and directed.
104Supply and fixing in replacement of Aluminiumlugs of size 70 Sqmm to 120 Sqmm and tightening of all connecting points, cable connection complete all as specified and directed by Engineer-in- Charge
105M&L for sub main wiring with two run of10 sqmm single core multi stranded PVC insulated and unsheathed copper conductor(red for phase and black for neutral) of grade 1100 volt FRLSH cable in and including 1100 volt electrical grade PVC Conduitof desired colour not less than1.2 mm thick and 25 mm wide& 10 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one.
106All as per item No.88 above, but size 10 Sqmm four runs andwith one run 10 sqmm FRLSH copper wire for earth continuity.
107All as per item No.88 above, but size 6 Sqmm four runs andwith one run 6.0 sqmm FRLSH copper wire for earth continuity.
108All as per item No.88 above, but size 6 Sqmm two runs andwith one run 6.0 sqmm FRLSH copper wire for earth continuity.
109All as per item No.88 above, but size 4 Sqmm four runs andwith one run 4.0 sqmm FRLSH copper wire for earth continuity.
110All as per item No.88 above, but size 4 Sqmm two runs andwith one run 4.0 sqmm FRLSH copper wire for earth continuity.
111All as per item No.88 above, but size 2.5 Sqmm two runs andwith one run 2.5 Sqmm FRLSH copper wire for earth continuity.
112M&L in replacement maintenance free grounding solution set earthing comprising of earthing rod, outer pipe in GI and having minimum diameter of 76mm, 3m in length and inner pipe to have minimum diameter of 32mm, both end properly welded to make them airtight. GI terminal size of 100 x 50 x 6mm with 2 Nos M8 holes for termination area in between two pipes filled with dry type chemical powder having high conductivity and make sure no air pockets are left. Electrode must be tested for short circuit test of minimum 40 kA at CPRI/NABL. The earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 Mtr. The bore drilling will be donewith the help of Pneumatic boring machine, 50 Kgs BFC will be placed in the bore to cover the earthing rod from all sides. BFC will be poured in slurry form in properly mixed condition. The Earth pit cover square 300 x 300 x 240 mm to be provided to cover the earth pit and shall be made of reinforced FRP and should be capable of carrying the weight of 5 Tons. Make : U-PROTECearthing/Shivangi Engineering works (Earth SOL-3)/JEF techno solution Pvt Ltd (JEF ECOSAFE)
113Note :- (a) Rates of boring 3.5 Mtr for earth electrode, GI strip 20 x 3 mm & 40 mm dia protection pipe upto 7.5 Mtr from earth electrode is deemed to be included in the quoted rate. (b)On testing, after completion, if the earth resistance <2 ohms is not obtained, earthing will be done again at no extra cost till the desired earth resistance is obtained. (c) Test certificate from the OEM has to be produced by the contractor for the material used in earthing.
114S&F MCB distribution board Double door SPN 240 volts 12 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc incltaking down old unserviceable one.
115M & LMCB distribution board double door 415 volt, TPN4-way,incl taking down old unserviceable
116S&F load line vertical TPN distribution board 4 way including 1 incommer MCCB of 125 Amps 4 pole double door IP-43 protection, powder coated, IK08 with provision of suitable size bus bar and cable management kit complete including taking down old unserviceable one all as specified and directed.
117Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl using suitable clamp of cross sectional area4 core 25 Sqmmin and including taking out old one all as specified and directed.
118All as per item No.99 above, but 3.5 core 35 Sqmm
119Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deepand making goodsurface for laying /removing of cable all as specified and directed by Engr in charge as in
120Soft/loose soil
121Hard/dense soil
122Returning, filling in, excavated soil in trenches, including watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
123Removal of surplus excavated spoil to distance not exc. 50metre and deposting where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
124Supply & Laying in replacement of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smooth internal and profiled external surface for non pressure under ground cableincl couplers & bends complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail