Tender For Rate Through E - Quotations Are Invited For Material Category Annexed As 5 H.P. Dc Solar Pump,Vfd, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme, hazaribag-Jharkhand

Water Resources Department-WRD has published Tender For Rate Through E - Quotations Are Invited For Material Category Annexed As 5 H.P. Dc Solar Pump,Vfd, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme. Submission Date for this Tender is 30-11-2022. Distribution Box Tenders in hazaribag Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

34990401
Tender For Rate Through E - Quotations Are Invited For Material Category Annexed As 5 H.P. Dc Solar Pump,Vfd, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme
Open Tender
Indian
Jharkhand
hazaribag
30-11-2022

Tender Details

Rate Through E - Quotations Are Invited For Material Category Annexed As 5 H.P. Dc Solar Pump, Vfd, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme , For 5 Hp Spv Dc Surface Pump , Solar Module Mounting ( Galvanised Steel ) Surface Structure ( For 5 Kw ) Having Hot Deep Galvanised Ofzinc Thickness 80Micron And As Per Is4759 With C Channel $ Anti Theft With Nut Bolt Of Grade Ss304, Which Should Also Withstand High Wind Velocity Upto 150Km / Hr Or As Per Mnre. , 5 Kwp Spv Module Of 330Wp Or Higher Rating, Which Must Have Specification As Per Is 14286 / Iec 61215 .The Module Must Have To Quilifyis / Iec 61730 Part I $ Ii ( Or Having Mechanical Load Test Of 5400Pa ) For Safety Purpose.Module To Module Wattage Mismatch In Spv Array Shall Be + / -3% And To Qualify Iec Ts 62804-:2015 For The Detection Of Potential Induced Degradation And Warranted For Output Wattage Not Less Than 90% In 10Yrs And 80% At The End Of 25Yrs As Per Mnre. , Spv Controller / Vfd Integrated With Gprs, Having Mppt , Protection Ip 65 Or Above As Per Mnre To Run5 Hp Dc Solar Pump. , Solar Cable 4 Mm2usedas Per Is 694 Or As Per Mnre. , Copper Cable 4 Mm23 Core Used As Per Is 694 Or As Per Mnre. , Arrangement Of Lightening Arrestor Excluding Earthing For 5 Kw & 2 Nos. 5 Hp Solar Pump , 5 H.P. D.C. Solar Pump Set Ofhaving Performance With Respect To Total Head, Maximum Current, Capacity, Voltage Range Etc As Per Mnre Guidelines. , Array Junction Box ( Ip 65 Or Above ) As Per Mnre For 5 Kw Spv. , Miscllaneous Accessories For Installation Of 5 H.P. Solar Pump , Supplying, Installation And Commissioning Charge Of Module And Structure For 5 Kw. , Maintenance For Atleast 5 Years Or As Per Mnre Guidelines For 5 Kw Spv Module & 2 Nos. 5 Hp D.C. Solar Pump With All Accessories

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Inviting quotation for Supplying Different Item of works regarding installation of 5 HP SPV DC surface Pump
Sl. No. Item Description
1For 5 Hp SPV DC Surface Pump
2Solar Module Mounting (Galvanised Steel) surface structure (for 5 kW) having Hot deep galvanised ofZinc thickness 80micron and as per IS4759 with C Channel $ anti theft with nut bolt of grade SS304,which should also withstand high wind velocity upto 150km/hr or as per MNRE.
35 kWp SPV module of 330wP or higher rating, which must have Specification as per IS 14286/IEC 61215 .The module must have to quilifyIS/IEC 61730 part I $ II (or having mechanical load test of 5400Pa) for safety purpose.Module to Module wattage mismatch in SPV Array shall be +/-3% and to qualify IEC TS 62804-:2015 for the detection of potential induced degradation and warranted for output wattage not less than 90% in 10yrs and 80% at the end of 25yrs as per MNRE.
4SPV controller/VFD integrated with GPRS,having MPPT ,Protection IP 65 or above as per MNRE to run5 HP DC Solar Pump.
5Solar cable 4 mm2usedas per IS 694 or as per MNRE.
6copper cable 4 mm23 Core used as per IS 694 or as per MNRE.
7Arrangement of Lightening Arrestor excluding Earthing for 5 kW & 2 nos. 5 HP Solar Pump
85 H.P. D.C. Solar pump set ofhaving performance with respect to Total Head,Maximum Current,Capacity, Voltage Range etc as per MNRE guidelines.
9Array junction box (IP 65 or above ) as per MNRE for 5 kW SPV.
10Miscllaneous Accessories for Installation of 5 H.P. Solar Pump
11Supplying,installation and commissioning Charge of Module and Structure for 5 kW.
12Maintenance for atleast 5 years or as per MNRE guidelines for 5 kW SPV module & 2 nos. 5 HP D.C. Solar Pump with all accessories