Military Engineer Services-MES has published Tender For Repair To Internal Electrification Including Meters Ceiling Fan. Submission Date for this Tender is 25-12-2022. Electrification Work Tenders in marathahalli Karnataka. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Nov-2022 | OTHER CORRIGENDUM1 | Other | 14-12-2022 |
2 | 08-Dec-2022 | BOQ CORRIGENDUM_3 | BOQ | 18-12-2022 |
3 | 08-Dec-2022 | DATE POSTPONEMENT CORRIGENDUM | Date | 18-12-2022 |
4 | 18-Dec-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-12-2022 |
Sl. No. | Item Description |
1 | Taking down unserviceable wire carefully copper/ aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., and making good the disturbed surfaces of walls, ceiling etc., including painting with same colour of the background, complete all as specified and as directed. |
2 | Wiring complete with 1.5 Sqmm single core FRLSPVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories surface type run on walls/ ceiling incl MS terminal boxesmounted concealed on walls with hylon laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket andoutlets, fan regulators etc., incl provision of 1.5 Sqmm FRLS PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. (a)One Light point controlled by one switch |
3 | (b)One fan/Ex. fan point controlled by one switch. |
4 | (c)One 5A 2pin/3pin switch socket out let multipurpose on independent Board. |
5 | (d)One call bell point controlled by one bell push |
6 | All as per item No -02 above but wiring complete with 2.5Sqmm for 5 pin 5/15A socket multipurpose on independent board. Note:- Item No2.00 to 3.00 (i) The earth wire for the points shall be laidfrom the respective switch board only . (ii) Earth wire shall be taken inside the conduit. (iii)Cost of terminal box is deemed to be included in the item rate quoted for point wiring |
7 | S & FSwitch piano flush type, single pole, one way5 Amps complete all as specified and directed |
8 | S & F Switch socket combination 2 -in-1, 3 pin/5 pin, 5 Amps 230 volts complete all as specified and directed |
9 | S & FSwitch Socket Combination 2 in 1, 3 pin 5 Amps and 15 Amps flush type , 230 volts complete all as specified and directed |
10 | S & Fstep type electronic fanregulator, - 2 module complete all as specified and directed |
11 | S& F PVC ceiling rosetwo to threeterminals complete all as specified and directed |
12 | S & Fding dong bell AC, 230 volts, single pole complete all as specified and directed |
13 | S & F Socket outlet 2 in 1, 3 pin, 5A Flush type 230 volts complete all as specified and directed |
14 | S & F Socket Outlet 2 in 1, 3 pin, 5 and 15 amp flush type 230 voltscomplete all as specified and directed |
15 | S & FSwitch Piano Flush type, Single pole, One way 230 volts 15 / 16 Amps complete all as specified and directed |
16 | S&FAngle holder PVC/polycarbonate type all as specified and as directed |
17 | S & F Modular Switch 1 way 6 Amps 1 Module complete all as specified and directed |
18 | S & F Modular Socket,6 Amps- 2/3 pin combined 2 Moduler complete all as specified and directed |
19 | S & F Modular Switch 1 way 16 Amps 1 Moduler complete all as specified and directed |
20 | S & F Modular Socket,6 A/16A,2 Moduler complete all as specified and directed |
21 | S & FModulartype Fan step regulator 120Wtype2 moduler complete all as specified and directed |
22 | Supply and fixing 600x600mm surface/ recessed mounted LEDLight fitting 36 /35 W,glare freeuniform illuminationacrylic diffuser,connector block etc., complete with all accessoriesand including connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and as directed. |
23 | Supply and FixingLED Tube light fitting 1 x20 W,220VCRCAhousing withPC diffuserbox type with driver,holder including LED tube light connecting upwith 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal all as specified and as directed. |
24 | Supply and fixing LED light fitting mirror type high out put diffuser 2 feet 10 W 220 V AC recessed/surfaced type high efficieny with drivers, holders LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed |
25 | Supply and fix LED light fittings 1X9/1X10 bulkhead luminaries including LED drive holder connecting up with thre core flexiable copper conductor cable |
26 | Supply and fix LED 20 Wattstube light ultra bright polycarbonate suited forwith G 13 Lamp holder all as specified and directed |
27 | Supply and fixinground shape LED recessed/ surface light fitting 15Wcomplete withdrivers ,holders LED lampsincluding connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal Complete all as specified and as directed. |
28 | Supply and FixingLED Bulb of 9 watts pin type all as specified and as directed. Make:Bajaj / CG / Havells |
29 | S&F MCB DB TPN4 way, double door,415 V, AC, 50 Hz complete all as specified and directed |
30 | Supply and Fixing MCB SP 5 to 32 Amps rating, 10 KAÇ "curve240V, 50 Hz AC Complete all as specified and as directed. |
31 | Supply and FixingMCB SPN 32 Amps rating,10 KA "C"curve, 240V, 50 Hz AC Complete all as specified and as directed. |
32 | Supply and Fixing MCB TP 25- 63 Amps rating, , 10 KA Ç" crve415V, 50 Hz AC complete all as specified. |
33 | Supply and Fixing in repairs MCB TPN 63 Amps rating,10 KA "C" curve , 415V, 50 Hz AC Complete all as specified and as directed. |
34 | Material and Labour forsub main wiring1100 volts grade PVC insulatedFRLS multistranded copper conductors, two runs of single core4 Sqmm along with one run 4 Sqmm PVC insulated single core FRLS multistranded copper conductor cable as earth continuity conductor along with one run of PVCconduit all as specified and as directed Note :-3 run ofmultistranded copperconductorand 1 run of PVC conduit shall be measured as one unit |
35 | Disconnecting the powersupply and taking down Ceiling fan ,Dismantling the defective Ceiling fans motor 1200mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material and other petty items required for making motor functional Complete all as specified and as directed. |
36 | Dis connecting the power supply and taking down the exhaust fan , dismantling the defective Exhaust fans motor up300 mm sweeptaking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, andother petty items required for making motor functional Complete all as specified and as directed. |
37 | Dis connecting the power supply and taking down the exhaust fan ,/wall mounting fandismantling the defective Exhaust fans motor up 400 to 450 mm sweeptaking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, andother petty items required for making motor functional Complete all as specified and as directed. Note: item No -32 to 34 - Servicing of Exhaustfans and Spares will be measured and paid separately under relevant items of this schedule. |
38 | Hanging Only Ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified ,and any addn/alteration /threading if required to down rod shall be done by contractor with out any extra cost Complete all as specified and as directed. |
39 | Supply Only GM bush suitable for Ceiling fan 1200 Sweep Complete all as specified and as directed. |
40 | Supply Only Ball bearings suitable for Ceiling fans / Exhaust fans / Wall mounting fans of 1200 Sweep Complete all as specified and as directed. Make: SKF / NBC / TATA or equivalent. |
41 | Supply Only 2.5 MFD Capacitors for the fan in position Complete all as specified and as directed. Make - Usha / CG/ Havells |
42 | Supply and fix ceiling fan complete with blades down rod electronic rerulator and accessories 230 V 1200 mm sweep Min air delivery 210 CFM five star brushless (BLDC) complete all as specified and directed |
43 | Supply and fix exhaust fansteel body AC single phase 230 V 300 mm sweep with blades and frame with louvers complete all as specified and directed |
44 | Taking out unserviceable geyser element including supplyandfixingheating elementsuitable to existing model and make 1.5 / 2 KW Dual clip type/tri angle type / round type with rubber gasketsuitable for geysers up to 25 Ltr capacity . |
45 | Taking out unserviceable thermostat including supplyandfixingthermostat clip type (Range 30 C° to 80 C and acting at 70C°) forgeysers up to 50 Lts all as specified . |
46 | Takingout un serviceable PVC connection including supplyand fixing15mmborePVC connections with brass nuts650 mm in length suitable to connect GI pipe 15 mm dia to hot /Cold water outlet of geyser complete all as specified and directed . |
47 | Taking out unservice pressure release valve including Supplyand fixing pressure release valves suitable for geyser up to 50 ltrs capacity type asper existing PR valve complete all as specified and as directed . |
48 | Taking out the unservieable 3 core wire including supply and fix FRLS PVC Round insulated copper flexible cable 2.5 sqmm , 3 core PVC sheathed,1100 Volts grade complete all as specified and as directed. |
49 | Excavation in trenches in Soft / Loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete all as specified and as directed. |
50 | Returning filling including Spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick Complete all as specified and as directed |
51 | Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils Complete all as specified and as directed. |
52 | Material and labour forriddledSandCushioning to cablesa layer of 8 cm thick beforelaying the cable and second layer of 15 cmthick after layingthe cable Complete all as specified and as directed. Note :- Sand shall be measured after punned down. |
53 | S & Fsub classburnt Bricks for cable protection Complete all as specified and as directed |
54 | Material and Labour for G.I. tubinglightgrade of size 50mm bore for protection of cables to be laid under roads, crossings / culverts Complete all as specified and as directed. |
55 | Taking out old unserviceable UG cable, Supply and laying 25 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed. |
56 | Taking out old unserviceable UG cable, Supply and laying 16 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed. |
57 | Taking out old unserviceable UG cable, Supply and laying 10 Sqmm, 2 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed. |
58 | Taking out old unserviceable UG cable, Supply and laying 10 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed. |
59 | Supply and FixingMCCB DB TPN 4 way,Double door, 415V, AC, 50 Hz, with 200 Amp rated bus bar |
60 | Supply and fix 415 KA"B" Curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commission TPN/FP 40 to 100 Amps all as directed and directed |
61 | Supply and Fixing MCCB Triple pole 415 volts 50 HZ AC suitable for current carrying capacity 25 to 100 Amps rating, fixed typewith rupturing capacity 16 KA all as specified and directed. |
62 | Supply and FixingMCCB3 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 630 Amps rating, fixed and thermal magnetic release with rupturing capacity 50 KA all as specified and directed. |
63 | Supply and Fixing in repairs MCCB 3 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 160 Amps rating, fixed and thermal magnetic release with rupturing capacity 25 KA all as specified and directed. |
64 | Supply and Fixing in repairs MCCB 4 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 200 Amps rating, fixed and thermal magnetic release with rupturing capacity 35 KA all as specified and directed. |
65 | Supply and Fixing in repairs MCCB4Pole, 415 volts 50 HZ AC suitable for current carrying capacity400 Amps rating, fixed and thermal magnetic release with rupturing capacity 36 KA all as specified and directed. |
66 | Material and Labour for preperation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint Complete all as specified and as directed. |
67 | Supply and fixingmoulded (FRP) junction boxwith IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6Amp MCBSP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole complete all as directed |
68 | Supply and Fixing in repairs Voltmeter digital type 0-500 Volts Complete all as specified and as directed. |
69 | Supply and Fixing in repairs Ammeter digital type 0-200 Amps Complete all as specified and as directed. |
70 | Taking out the unserviceable HPSV /CFL street light fitting any watts , Supply and fixing 35 WLEDstreetlight fitting with pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection. |
71 | Taking out the unserviceableflood light fittingsSupply and fixing 70 WLED flood light fitting230V out door type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistants complete with driver and lamp |
72 | Taking out the unserviceable post top latern fitting ,Supply and Fixingpost top lantern LED type 20 W 230 VoltsAC out door typewith decorativepost top for 360 degree indirect light IP65protection with impact and corrosionresistantCompletewith driver and lamp |
73 | Repair/ servicing of out door typeAPFC panelat Akash Vihar :- (i) APFC panel (out door Type) 100 (8x12.5) KVAR - 02 No , (ii) APFC panel ( Out door Type) 125 (20x5,2X12.5) KVAR - 01 No capacitors, internal wiring,inresh current limiting coil ., auxillary contactor, indicating lamps, auto-manual selector switch, MCCB, axial flow fan and replace the unserviceable parts complete all as specified and as directed. The following checking will be carried outto ensure smooth and effective operation all the timeall as specified and directed. (a) Checking of the control panel, power supply, fuses, circuits etc and tighten to any loose contact.(b) Checking of the healthiness of capacitors, contactors and APFC relays. (c) Cleaningof the panel by using blower without any disturbance/ damages. Note:- spare parts materialwill be measured and paid separately under relevant items of this schedule. |
74 | Supply Only in repairs10/12. 5 KVAR Capacitor heavy duty existing make and type440 volts with inrush current Limiting Coil Complete all as specified and as directed. |
75 | Supply Only in repairs 20KVAR Capacitor heavy duty existing make and type440 volts with inrush current Limiting Coil Complete all as specified and as directed. |
76 | S&F heavy duty contactor suitable for 25Kvar capacitor complete all as specified and as directed. |
77 | Supply Only Automatic power factor relay ( APFCR )8 stage complete all as specified and as directed. |
78 | Supply only duty contactor suitable for 20Kvar capacitor |
79 | Supply only duty contactor suitable for12.5 Kvar capacitor |
80 | S&F duty contactor suitable for 25Kvar capacitor |
81 | S&F duty contactor suitable for 12.5/ 10 Kvar capacitor |
82 | M&L danger notice plate of 1.6 mm thick mild steel sheet vitrous enamelled white letters fifgre and conventional skull and bones in single red colour and fixed with MS clamps bolts and nuts of approved size for LT 20X15cm size |
83 | All as per item no 79 above, but,HT 25X20cm size |