Tender For Repair/Maintenance /Replacement Of Lt Control Panel, Lt Cables, Feedar Pillar Box, Acsr Conductor, Sub-Station Earthing And Connected Works In Domestic And Technical Area At Af Stn Bihta, bihta-Bihar

Military Engineer Services-MES has published Tender For Repair/Maintenance /Replacement Of Lt Control Panel, Lt Cables, Feedar Pillar Box, Acsr Conductor, Sub-Station Earthing And Connected Works In Domestic And Technical Area At Af Stn Bihta. Submission Date for this Tender is 19-12-2022. Electrification Work Tenders in bihta Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

34955767
Corrigendum : Tender For Repair/Maintenance /Replacement Of Lt Control Panel, Lt Cables, Feedar Pillar Box, Acsr Conductor, Sub-Station Earthing And Connected Works In Domestic And Technical Area At Af Stn Bihta
Open Tender
Indian
Bihar
bihta
19-12-2022

Tender Details

Tender For Repair / Maintenance / Replacement Of Lt Control Panel, Lt Cables, Feedar Pillar Box, Acsr Conductor, Sub-Station Earthing And Connected Works In Domestic And Technical Area At Af Stn Bihta

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Dec-2022 Corrigendum No 1 BOQ 12-12-2022
2 12-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 10 Lakhs /-

BOQ Items

Name of Work: Repair/Maint/Replacement of LT Control Panel, LT Cables, Feedar Pillar Box, ACSR Conductor, sub-station earthing and connected works in domestic and technical area at AF Stn Bihta
Sl. No. Item Description
1Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed.
2Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and as directed.
3Removing of excavated material not exc 50 mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified.
4M&L for laying of pulverized fuel ash lime bricks (Flyash bricks), old size, laid flat perpendicular to the direction of cable for protection of cable, complete all as specified.
5M&L for sand cushioning for cable with river washed sand and punning to provide required cover as per SSR Part –I, complete all as specified and directed.
6M&L PCC 1:4:8 type D-2, using 40 mm graded crushed stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
7M&L PCC 1:3:6 type C-2, using 40 mm graded crushed stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
8S&F GI tubing, light grade, with all fittings and laid in trenches/under roads, drains etc, or fixed to poles/walls with FI clamps, nut, bolts etc and making good disturbed surfaces, complete all as specified and directed for the following bore of pipes: - a) 50 mm bore
9b)80 mm bore
10Material & Labour for jointing testing Indoor/out door type cable termination (heat Shrinkable) jointing kit for 1100 Volts underground XLPE cable of size 25 to 50 Sqmm 3 ½ core including taking out old/unserviceable joints complete all as specified and directed. Make : DENSON/3M/M-seal
11Description all as per Srl item 9 here-in-before but for cable of size 70 to 150 Sqmm 3 ½ core. Make : DENSON/3M/M-seal
12Description all as per Srl item 9 here-in-before but for cable of size185 to 300 Sqmm 3 ½ core Make : DENSON/3M/M-seal
13Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor, wall etc locate the fault, rectify the defect and relaying the XLPE cable under ground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts/11000 volts connecting and testing for any size complete as directed. (Excavation, earth work, brick protection, sand cushioningand GI pipe etc shall be measured & paid for separately)
14Supply, Laying, connecting and testing XLPE cable underground PVC insulated and over all sheathed with stranded aluminium conductor heavy duty 1100 volts grade laid in trenches, floors, ducts passing through pipe for road crossing etc including taking down old UNSV cable of any size complete all as specified and directed for the following size of cables: - (excavation, earth work, brick protection sand cushioningand GI pipe etc shall be measured & paid for separately) of following sizes :- (a) Cross sectional area 10 Sqmm 4 core
15(b) Cross sectional area 16 Sqmm 4 core
16(c) Cross sectional area 35 Sqmm 3 ½ core
17(d) Cross sectional area 70 Sqmm 3 ½ core
18(e) Cross sectional area 95 Sqmm 3 ½ core
19M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead strip 32x6mm as earthing leadby means of bolts, nuts, check-nuts, and washers of galvanised iron or steelincluding excavation and earth work, GI pipe medium grade 40 mm bore for protection of GI strip from earth electrodeto test point /machinery / equipment.supplying and laying charcoal dustcomman saltPCC(1:2:4) type B1 using 20 mm graded crushed stone agregratechamber andRCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1using 20 mm graded crushed stone aggregates,reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia,using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No-3 of SSR part-1 and testing on completion, complete all as specified and directed. Note - Cost of GI earth wire and GI protection pipe up to a distance 7.5 M shall be deemed included in quoted rate of above Items.
20M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4mm dia as earthing leadby means of bolts, nuts, check-nuts, and washers of galvanised iron or steelincluding excavation and earth work, GI pipe medium grade 15 mm bore for protection of GIwire from earth electrodeto test point /machinery / equipment.supplying and laying charcoal dustcomman saltPCC(1:2:4) type B1 using 20 mm graded crushed stone agregratechamber andRCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1using 20 mm graded crushed stone aggregates,reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia,using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No-3 of SSR part-1 and testing on completion, complete all as specified and directed. Note - Cost of GI earth wire and GI protection pipe up to a distance 7.5 M shall be deemed included in quoted rate of above Items.
21Re-stretching existingACSR conductor on poleand binding conductor on insulator properly using new binding wire/jumper wire complete all as directed at site by Engr-in-Charge. Note : Each line of conductor shall be measured & paid for separately.
22Labour only for trimming/cutting of tree branches obstructing the LT over head lines upto 2 mtr and deposit the same where directed, complete all as specified and as directed.
23S&F MCB’s single pole and neutal, 10 KA, 40 Amp, 240 Volts, and of ""C"" series with required wiring connections and lugs etc and erecting in provided enclouser/distribution board. MCBs shall be of current limiting type, ISI marked conforming to IS 8828-1996 and complete all as directed and specified.
24S&F MCB’s single pole and neutal, 10 KA, 63 Amp, 240 Volts and of ""C"" series with required wiring connections and lugs etc and erecting in provided enclouser/distribution board. MCBs shall be of current limiting type, ISI marked conforming to IS 8828-1996 and complete all as directed and specified.
25Supply & Fixing MCCB TPN 415 Volts 125 Amps rating with breaking capacity of 25 KA with fixed thermal & magnetic settings complete with making all connections as specified and directed.
26Supply & Fixing MCCB TPN 415 Volts 160 Amps rating with breaking capacity of 25 KA with fixed thermal & magnetic settings complete with making all connections as specified and directed.
27Supply & Fixing MCCB TPN 415 Volts 200 Amps rating with breaking capacity of 25 KA with fixed thermal & magnetic settings complete with making all connections as specified and directed.
28Supply & Fixing MCCB TPN 415 Volts 250 Amps rating with breaking capacity of 25 KA with fixed thermal & magnetic settings complete with making all connections as specified and directed.
29S&F MCB’s single pole, 10 KA , 40 Amp, 240 Volts and of ""C"" series with required wiring connections and lugs etc and erecting in provided enclouser/distribution board. MCBs shall be of current limiting type, ISI marked conforming to IS 8828-1996 and complete all as directed and specified.
30S&F MCB’s single pole, 10 KA , 63 Amp, 240 Volts and of ""C"" series with required wiring connections and lugs etc and erecting in provided enclouser/distribution board. MCBs shall be of current limiting type, ISI marked conforming to IS 8828-1996 and complete all as directed and specified.