Public Works Department-PWD has published Tender For Renovation Of The Electrical Wiring Of The Office Of The Special Land Acquisition Office, District Of Bankura, Under Bankura Electrical Division, Pwd.. Submission Date for this Tender is 30-11-2022. Electrification Work Tenders in bankura West Bengal. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch of grey/black colour(Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as approved byE.I.C) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mendinggood damages to original finish as per GS.On Board [ 3 (a) / E- 24 ] |
2 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch of grey/black colour(Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as approved byE.I.C) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works as per GS.On Board [ 3 (a) / E- 24 ] |
3 | Supplying and fixing PVC Rigid Conduit "FR" [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works 20 mm size[ 7(a)/ E- 16 ] |
4 | 25 mm size[ 7(b)/ E- 16 ] |
5 | Supplying and Drawing 1.1 KV single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. 3 x (1.5 sqmm) [1(b) / E- 9 ] |
6 | 2x(2.5 sqmm)+1x(1.5 sqmm)[ 1(s) / E-9 ] |
7 | 2x(4 sqmm)+1x (2.5 sqmm)[ 1(v) / E- 9 ] |
8 | 2x(6 sqmm)+1 x (4 sqmm) [ 1(y) / E- 9 ] |
9 | S & F solderless Copper socket by crimping of Copper wires.a)1.5 sq mm |
10 | b) 2.5 sq mm[9(i) / F-5] |
11 | c) 4 sq mm[9(ii) / F-5] |
12 | d) 6 sq mm [9(iii) / F-5] |
13 | Supplying & Fixing GI inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS 175 x 100 x 65 |
14 | 200 x 150x 65 |
15 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12 Way [Legrand Enclosure 607711 /Schneider Enclosure-(A9HSND012) or equivalent model of L&T] as per direction of EIC.[ 13 / D- 9 & D-10 ] |
16 | 2+6 Way [ /Schneider Enclosure-(A9HSND06)/ Seimensor equivalent model of Legrand] as per direction of EIC.[ 13 / D- 9 & D-10 ] |
17 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ] 32 A DP [ 6 / D- 5 ] |
18 | 40 A DP [ 6 / D- 5 ] |
19 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/L&T) as per direction of EIC. ]6-32 SP[ 7 / D- 6] |
20 | 16 SP7 / D- 6] |
21 | Supplying and fixing 240V, 32 A DP Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. [ Make L&T / Havells / HPL] |
22 | Supplying & fixing 500x150mm sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required –4 bars 440 V, 100/125 A Dimension of Al. Bars [85mm long] m 2 x 25x5mmDimension of Sheet Metal Box |
23 | Supplying and fixing 240V,63A Sheet steel Main Switches on angle iron frame on wal(Havells/Standard) [1(b)/D-1] |
24 | Supply of2 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make : Gloster/KEI/Polycab/ Havells/RR Kabel] 2 Core 25 Sq. mm[ NS ] |
25 | Laying of cable of following sizes on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting as per GS.upto 2 core 25 sqmm [2-a/F-1] |
26 | Supplying and fixing compression type gland and finishing thoseforfollowing XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.2 Core 25 Sq. mm |
27 | Supply & Fixing240 V, 25 A, 3 pin Modular type plug socket of grey/black colour(Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as approved byE.I.C), without plug top and switch with 2 Module GI Modular type switch board with top cover plateflushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 5(a) / E-17] |
28 | Supply & Fixing240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.[ 5(b) / E-17] |
29 | Supply & Fixing240 V, 25 A, Modular type AC starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plateflushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17 / E-19] |
30 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
31 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required[26 / E-7] |
32 | Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube [NS]Twin Fittings (make- Philips, Cat No. TMC-501 P1xT-LED 22W P3242 or equivalent model of CG / Bajaj / Wipro) incl. 2 no. 18W Master LED Tube 2100 lm 865T8 (VE) |
33 | Fixing only single/twin LED batten light fitting suspended fromthe ceilingfixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ] |
34 | Supply of ceiling fans with burst-proof P2/S3 Capacitor including safety wire,complete with all accessories without regulator.( Make - Usha-Striker or equivalent model of CG/Orient)1200 mmSweep |
35 | Supply & Fixing240V, Modular Socket (2 Module) type fan regulator (Step type)of grey/black colour(Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as approved byE.I.C) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18] |
36 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ] |
37 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS[ 2(a)/G-1] |
38 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2] |
39 | Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1] |
40 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode [3(b)/G-2] |
41 | Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS No.-8 SWG [5(a)(iii)/G-2] |
42 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS[4(a)/G-2] |
43 | Dismantalling of Electrical Item and keep at stack yeard accroding to EIC |
44 | Supplying & fixing of 5 amp piano key type switch on existing board. |
45 | Supplying & fixing of 5 amp piano flush type socket on existing board. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail