Tender For Amnari And Adjoining Villages Coverage Rural Water Supply Scheme, Under D. W. S. Division Giridih - 2 On Turnkey Basis., giridih-Jharkhand

Drinking Water And Sanitation Department has published Tender For Amnari And Adjoining Villages Coverage Rural Water Supply Scheme, Under D. W. S. Division Giridih - 2 On Turnkey Basis.. Submission Date for this Tender is 30-11-2022. Centrifugal Pump Tenders in giridih Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

34923211
Tender For Amnari And Adjoining Villages Coverage Rural Water Supply Scheme, Under D. W. S. Division Giridih - 2 On Turnkey Basis.
Open Tender
Indian
Jharkhand
giridih
30-11-2022

Tender Details

Amnari And Adjoining Villages Coverage Rural Water Supply Scheme, Under D. W. S. Division Giridih - 2 On Turnkey Basis.-Detailed survey, designing and drawing, Construction of 2.50 MLD capacity Water Treatment Plant, ESR No. 1 – 290 KL capacity with 24 M staging, ESR No. 2 – 360 KL capacity with 20 M staging, Staff Quarter, Compound wall,Supplying and laying Raw, Clear Water rising main and Distribution Network, House Connection, Intake well, Gangway, Infiltration Gallery, Supplying and Installation of Vertical Turbine & Centrifugal pump motor and Five years operation & maintenance with allied works etc. all complete job for AMNARI & Adjoining Villages Coverage Rural Water Supply Scheme, Under D. W. & S. Division Giridih - 2 on turnkey basis.”

Key Value

Document Fees
INR 10000 /-
EMD
INR 2220000.0 /-
Tender Value
INR 22.19 Crore /-

BOQ Items

Name of Work: Detailed survey, designing and drawing, Construction of 2.50 MLD capacity Water Treatment Plant, ESR No. 1 – 290 KL capacity with 24 M staging, ESR No. 2 – 360 KL capacity with 20 M staging, Staff Quarter, Compound wall,Supplying and laying Raw, Clear Water rising main and Distribution Network, House Connection, Intake well, Gangway, Infiltration Gallery, Supplying and Installation of Vertical Turbine & Centrifugal pump motor and Five years operation & maintenance with allied works etc. all complete job for AMNARI & Adjoining Villages Coverage Rural Water Supply Scheme, Under D. W. & S. Division Giridih - 2 on turnkey basis.”
Sl. No. Item Description
1WATER TREATMENT PLANT
2Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority and Providing all labours and necessary equipment for designing & construction of Unconventional WTP of 2.50 MLD capacity. With all complete job. (Please refer to Section 5, Sl. 2.3 of SBD)
3Elevated Service Reservoir
4Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority and Providing all labours andequipment for designing & construction ofESR all complete job. (Please refer to Section 5,Sl.2.8 of SBD)
5ESR
6Zone - 1 ESR Capacity 2,90,000 Litres, Staging height - 24 M
7Zone - 2 ESR Capacity 3,60,000 Litres, Staging height - 20 M
8Intake Well With Pump House 5.00 M dia.
9Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority and construction of R.C.C Intake well with Pump house all complete job. (Please refer to Section 5, Sl. 2.1 of SBD)
10Earthwork in excavation of foundationtrenchesof toe wall Spillway head regulator, outlet, intake well etc.as per a designed section in allkinds of soil, including moorum soil, soil mixed with kankar, pebbles and boulders upto 300 mm size and disposal of the same (beyond 50 M away from the edge of the trenches) with in initial lead of 150 M all lifts of 1.5 M as per specification and direction of E/I.
11Initial Lift
121st Lift
132nd Lift
143rd Lift
154th Lift
165th Lift
17Earthwork in excavation of foundation trenches of toe wall spilllway, head regulator intake well , outlet etc. as per designed section in hardrock where blasting isneeded and stacking properly in approved stack size in approved stack yard beyond 50m from the edge of the trenches in the country side) with initial lead of 150m. and initial lift of 1.5m. as per specification and direction of E/I (Excavated hard rock size should not be more than 150 lb.).
186th Lift
19Plain/Reinforced cement concrete,in well foundation complete as per drawing and technical specification.
20Foundation PCC-150.
21RCC M-300,using concrete mixer. In Foundation RCC - M - 300
22RCC M-300,using concrete mixer. For RCC M-300 grade Slabs/Landings/Vertical Walls/ Waist Slabs/Steps for Staircase in Foundation stainingwall of IntakeWell:
23Furnishing and placing Reinforced/Prestressed cement concrete in super-structure as per drawing and technical specification. For RCC M-250 grade Beams/ Braces/ Lintels & pumpe house roof slab (2 No for floor slab)
24Furnishing and placing Reinforced/Prestressed cement concrete in super-structure as per drawing and technical specification. For RCC M-250 grade Slabs / Landings / Vertical Walls / Waist Slabs / Steps for Staircase Forfloorslab
25Furnishing and placing Reinforced/Prestressed cement concrete in super-structure as per drawing and technical specification. Columns upto Roof level
26Furnishing and placing Reinforced/Prestressed cement concrete in super-structure as per drawing and technical specification. For Band at lintel level+Roof level
27Furnishing and placing Reinforced/Prestressed cement concrete in super-structure as per drawing and technical specification. Pump House Roof
28Providing 63 mm average thick RCC M-200 with nominal mix of in chhajja with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3 including, taking drip course in concrete screening, centering, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, 6 mm thick cement plaster (1:4) in ceiling and sides of chhajja with sand ofFM 1.5, curing (but excluding the cost of reinforcement) taxes and royalty all complete asper building specification and direction of E/I. Over Doors & Windows.
29Providing TMT reinforcement (TOR steel) 12 mm as per approved design drawing, removal of rust cutting, bending, binding including supplying annealed wire placing MS rods in position all completejob as per specification and directionof E/I.
30Providing designation 75A brick work in CM 1:6 in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, costs of screening, materials, scaffolding, racking out joints to 15 mm depth curing, taxes and royalty all complete as per building specification & direction of E/I.
31Supplyingfitting and fixingfull glazed steel Supplying fitting and fixing fully glazed steel door windowor ventilators standard rolled Z and mullion section andsizes as per I.S.-1038 joints met and welded with 100 x16 x 3 mm MSlugsfixedincement concrete (1:2:4) blocks 15 x 10 x 10 cm size including cost of oxidized iron fitting with hinges, handle per steps, catch springs 3 mm thick plain glass panes with Aluminium beads and inner frame fixed with lugs of 20 mmlong 6.3 mm G.I. counter sunk machine screw and nuts and applying acoat of red lead paint, carriage to work site hoisting and placing in position in all storey and taxes all complete as per building specification and direction of E/I.
32Supplying fitting & fixing collapsible gate of approved size and make properly fabricated with vertical double channel 20 x 10 x 2 mm, at 100 mm centres and braced with MS flat diagonals 20 x 3 mm with top and bottom rails of T irons 40 x 40 x 6 mm with 38 mm dia steel pulleys complete with bolts nuts locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage, hoisting and taxes all complete as per building specification & direction of E/I .
33Providing 12 mm thick cement plaster (1:6) with cleancoarse sand of FM 1.5including screening, curing with all leads andlifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.
34Providing 12 mm thick water proof cement plaster (1:3) with clean coarse sand of FM 1.5 with 5% cico or any other water proofing compound including screening curing,with all leads and lifts of water, scaffolding taxes and royalty all complete as per buildingspecification and direction of E/I.
35Providing 6 mm thick cement plaster (1:4) in ceiling of P/H& jack well with clean coarse sand of FM 1.5 including screening, curing with all leads and lift of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
36Providing two coat of snowcem of approvedshade and make over a coat of cement of primer on new surfaceincluding preparing the plasterded surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I.
37Providing two coat of painting with ready mixed paint of approved shade and make oversteelsurface including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
38Providing & fixing R.S joist ISMB 300 x 140 mm size fitting and fixing in possion including cutting to required in shape and size, its carrage applying a priner coat of red lead paint etc. all complete job and direction of E/I .
39Providing & Fixing G.I.Pipe Railing having 1.0 m height consisting 50 x 50 x 6mm thick M.S.Angles as verticals at 1.5 m c/c, and additional poles at every corner with three rows of 25 mm dia G.I.pipes of medium class variety as horizontal &painting three coats of oil paint over 1 coat of anticorrosive paint of approved colour & shade including cost of all labour,transporting bends to urved shape, etc.complete.
40Supplying materials and labou for fixing 20m dia M.S.bar steps in stening wall of 0.30 m intrenal and staggered in (1:2:4) cement concrete including scaffolding and curing etc.all complete as per specifiction and Direction of E/I.
41Providing and fixing MS sluice gates in position as per dtailed drawing and specification including cost of all materials, labour, operating pedestal, connecting rod, painting with three coats of anti-corrosive paint, etc. complete as directed by Engineer-in-charge.
42Providing and Fixing in Position C.I. M.S. Rose Piece in Intake Well including cost of all Materials and labour, Painting with Three coats of Anti-Corrosive paint, etc. complete as Directed By Engineer-In-Charge.
43Carriage of material from divisional store are kiln side or quality side to work including  contractor profit loading, unloading transportation are complete.
44Cement10KM lead
45Steel 10KM lead
46Sand 36KM lead
47Bricks06KM lead
48Stone/Stone Chips11KM lead
49Doing Geotechnical survey, Collecting field data, designing aesthetically, getting it approved by competent authority and Providing all labours andequipment for designing & CONSTRUCTION OF 3.00 M WIDE AND 50 M LONG APPROACH BRIDGE (GANGWAY) FROM INTAKE TO WTP(pl.refer to Sec-5 Sl.no. 2.2 of SBD for technical specification)
50Earthwork in excavation of foundation trenches of toe wall, spillway, head regulator, outlet, intake well etc. as per designed section in all kind of soil including moorum soil , soil mixed with kankar, pebbles and boulders upto 300 mm size and disposal of the same(beyond 50m away from the edge of the trenches) with initial lead of 150 m and initial lift of 1.5m as per specification and direction of E/I.
51Initial lift
52First lift
53Second lift
54Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specification. PCC-150
55Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specification. In Raft foundation (For R.C.C M-300)
56Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specification. (For Foundation Beam, M-300)
57Furnishing and placing reinforced / prestressed cement concrete in super-Structure as per drawing and technical specification. For Columns, M-300
58Furnishing and placing reinforced / prestressed cement concrete in super-Structure as per drawing and technical specification. For Bracings, M-250
59Furnishing and placing reinforced/prestressed cement concrete in super-Structure as per drawing and technical specification., M-250
60Furnishing and placing reinforced / prestressed cement concrete in super-Structure as per drawing and technical specification., M-250
61roviding (tor steel) reinforcement of 10 mm, 12 mm, & 16 mm. dia bars as per approved design and drawing excluding carriage of bars to work site cutting, bending,binding with annealed wire with cose of wire, removal of rust, placing the rods in position all complete as per Specificationand direction of E/I.
62Providing12 mmthick cement plaster(1:4) with approved quality ofsandofrequisite F.M. (2.5 to 3.0) washed and screened ncluding curing, scaffolding wherever required and its removal royalty andall taxes etc. complete job as per specification &direction of E/I.
63Providing 6 mm. thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification & direction of E/I.
64Providing and fixing GI pipe railing having 1.0 M height consisting 50 x 50 x 6 mm thick MS angles as verticals at 1.5 m c/c and additional posts at every corner with 3 rows of 25 mm dia GI pipes of medium class veriety as horizontal and painting 3 coats of oil paint over one coat of anticorrosive paint at approved colour and shade including cost of all labour, transporting bends to curved shape etc. complete.
65Providing two coat of snowcem of approvedshade and make over a coat of cement of primer on new surfaceincluding preparing the plasterded surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I.
66Carriage of materials from divisional store or kiln site or quarry site to work site including contract profit, loading, unloading, transportation, etc. all complete.
67Cement10KM lead
68Steel10KM lead
69Sand36KM lead
70Stone/Stone Chips11KM lead
71Infiltration Gallery
72Earthworkin excavation(As per I.S. 3114/1965) for laying of different types and sizes of pipes so as to give one meter average cover over the socket of pipe with disposalof excavated earth within initial lead and lift as perspecification and direction of Engineer-in-charge.
73Lift DI Pipe
74Lift V-Screen Pipe
75Lift DI Pipe
76Lift V-Screen Pipe
77Lift DI Pipe
78Lift V-Screen Pipe
79Providing at siteof works ISI standardwelded D.I Double flanged pipe excluding GSTLevied by GOI & GOM inall respect ,Railway Frieght … Complete as directed by EIC (for-2.75m bore pipe)
80250 mm dia. DI - K7 For Header
81Design and Supply of Apollo V- wire screen laterals Suitable for Infiltration Gallery as per site condition and detail provided End connection – Suitable flange Dia. – 06 inch (153 mm) I.D.= 153 mm O.D. = 167 mm Screen thickness = 07 mm Slot – 1.00 mm Moc Low Carbon Galvanised Steel, Length :- 5 Mtr.
82Lowering laying and jointing MS/ slotted pipes of following diameters includingall leads and lifts , cost of jointing material ,labour etc. complete as directedby Engineer- in -charge.
83Header pipe 250 mm dia.
84V Screen pipe 150 mm dia.
85Providing, lowering, laying and placing in position shrouding material for porous pipe gallery/slotted pipe gallery trench gallery with all leads and lift in valved screening and washing of materials as per directed by Engineer in Charge.
86for 40 mm Pebbles
87for 10 mm to 12 mm Pebbles
88for 6 mm to 12 mm Pebbles
89Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compactedand fine dressed with earthobtained after cutting within a leadof 50 M and lift of 1.5 m all complete as per building specification and direction of E/I. (made of measurement compacted volume ).
90Dewateringthe excavated trenches and pools of water in the building trenches/pipeline trenches,well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc all complete.
91Providing and supplying ISI standard DI specials & fittings with sealing rubber gasket of SBR, complete with cast iron follower gland and MS nut bolts coated or otherwise protected from rusting and suitable for DI Pipes complete as per IS - 9523 Class K-12. Note: - Rates are F.O.R. Jharkhand but excluding of GST.
92Providing, constructing coffer dam in river basin / dam storages as per type design including excavation, filling,the middle portion with B. C. soil (in gunny bags if requried). Providing impervious / semi pervious materials on both side of B.C.soil (in gunny bags if required) including ramming, compacting to the satisfaction of Engineer-in-charge, till the complection of work including dismantling coffer dam after completion of works and disposing off the material as directed by the Engineer-in-charge.
93RAW WATER PUMPING MACHINERY & ELECTRICAL WORKS AT INTAKE WELL
94Supply, installation, testing and commissioning of Vertical turbine pump sets with allied equipment as under-
95Pump Sets :- Supply, installation, erecting and commissioning of water lubricated Vertical Turbine Pump shall be of latest Indian Standards and manufacturing standards of suitable number of stages, operating at 1500 RPM for suitable discharge against required head, consisting of suitable bronze impellers, column pipe, pump shaft, etc. of Kirloskar/ WPIL/ Jyoti/ Mather & Platt make coupled with squirrel cage induction motor rating having 10% more rating of pump, operating on 1500 rpm,415V, 50Hz AC Supply of Kirloskar/ABB/ Merathon/Jyoti/ CGL make along with suitable base plate, spider bearing, strainer, sluice valve, NR valve, pressure gauge, delivery / suction piping work, Common Header, specials, bolt nut, spring washer, including construction PCC foundation, etc. all complete as per the instruction of EI.
96Discharge- 27.80 LPS and Head- 45 m (1W+1S)
97Starters :- Supply, installation, erecting and commissioning of assembled Fully Automatic Star Delta starter, in a provided cubical panel to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil, over load relay and ONOFF push buttons, with necessary material and connected to supply, etc complete.
98Power Distribution Panel :- Supply, installation, erecting and commissioning of Panel board shall be of latest Indian Standards and manufacturing standards at Intake well for power distribution. Floor mounted Panel board shall be fabricated with MS sheet of dust and vermin proof and painted consisting of4 pole power distribution 100 A TPN copper busbar, 1 no. incoming feeder of 100 A MCCB, 2 nos. outgoing feeder of 80 A MCCB for motors & 1 no. for Spare feeder, 2 nos. outgoing feeder of 32 A MCB & 63 AMCCB for lighting and utility, switch disconnector isolator, selector switches, MFM, Voltmeters, Ammeters, indicator lamps, protection units/relays, suitable capacitor banks/ APFC, internal wiring, etc. all complete.[MCCB make: L&T/ABB/ Siemens/ Schnieder]
99Cable:Supply, installation, erecting and commissioning of 50 Sq mm, 3.5 C, 1.1 KV grade, XLPE / PVC, armoured Aluminium Cablesfrom Transformer to Panel including laying, jointing, terminations, etc. all complete.
100Cable: Supply, installation, erecting and commissioning of 16 Sq mm, 3.0 C, 1.1 KV grade, XLPE/PVC, armoured Copper Cablesfrom Panel to Starter including laying, jointing, terminations, etc. all complete.
101Earthing: Earthing with copper earth plate including accessories and providing masanory enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc. with charcoal / coke and salt as required conforming IS:3043.
102Supply, installation, erecting and commissioning of internal and external lighting with suitable led lumenaries, wiring, distribution box, safety items,etc. at pump house including fire extinguisher & first aid box etc.
103Lifting Equipments :- Supply, installation, erecting and commissioning of triple spur gear type chain pulley block ISI marked and travelling trolley with 6m lift both tested for 50 % overload as per IS 3832(3 T capacity)
104Supply, installation, erecting and commissioning of internal and external lighting with suitable led lumenaries, wiring, distribution box, safety items,etc. at pump house including fire extinguisher & first aid box etc.
105Tansformer Installation: Cost of construction of DP structure in Rail / RSJ Pole for above mention transformer with different type of MS channels, M.S. angles, brackets, insulators, AB Switch, three set of horn gap fuse, DO fuse, disc & pin insulator, lightening arrester with earthing, stay sets, nut bolts, fabrication work required for the job, cost of earthing of transformer (Two nos., one no. for neutral and one for body) with all required material, technicians, labours, Grouting, PCC work, fencing, Danger board, testing of transformer oil, fitting, fixing, connecting with HT/LT lines, etc. forpower supply, etc. all complete as per I.E. rules and specification of Jharkhand state electricity board.
106CLEAR WATER PUMPING MACHINERY & ELECTRICAL WORKS AT WTP
107Supply, installation, testing and commissioning of Centrifugal pump sets with allied equipment as under-
108Pump Sets :- Supply, installation, erecting and commissioning of water lubricated Horizontal Split Casing/ Multi Stage Centrifugal Pump shall be of latest Indian Standards and manufacturing standards with suitable number of stages, operating at 1500 RPMfor suitable discharge against required head, etc. of Kirloskar/ ABB/ Jyoti/Mather & Platt make coupled with squirrel cage induction motor rating having 15% more rating of pump, operating on 1500 rpm, 415V, 50Hz, AC supply of Kirloskar/ ABB/ Merathon/ Jyoti/ CGL make along with suitable base plate, spider bearing, strainer, sluice valve, NR valve, pressure gauge, delivery/suction piping work, Common Header, specials, bolt nut, spring washer, including construction PCC foundation, etc. all complete as per the instruction of EI.
109Zone 1 & 2 : Discharge- 27.80 LPS and Head- 116 m (1W+1S)
110Starters :- Supply, installation, erecting and commissioning of assembled Fully Automatic Star Delta starter, in a provided cubical panel to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil, over load relay and ONOFF push buttons, with necessary material and connected to supply, etc complete.
111a) 100 HP
112Power Distribution Panel :- Supply, installation, erecting and commissioning of Panel board shall be of latest Indian Standards and manufacturing standards at WTP for power distribution. Floor mounted Panel board shall be fabricated with MS sheet of dust and vermin proof and painted consisting of (1)4 pole power distribution 315 A TPN copper busbar, (2) 1 no. incoming feeder of 315 A MCCB, (3) 2 nos. outgoing feeder of 250 A MCCB for motors & 1 no. for Spare feeder, (4) 2 nos. outgoing feeder of 63 AMCCB for WTP loads (5) 2 nos. outgoing feeder of 63 AMCB for lighting and other loads including switch disconnector isolator, selector switches, MFM, Voltmeters, Ammeters, indicator lamps, protection units/relays, suitable capacitor banks/APFC, internal wiring, with all required safety devices & accesories, etc. all complete.
113Cable:Supply, installation, erecting and commissioning of 240 Sq mm, 3.5 C, 1.1 KV grade, XLPE / PVC, armoured Aluminium Cablesfrom Transformer to Panel including laying, jointing, terminations, etc. all complete.
114Cable: Supply, installation, erecting and commissioning of 3.0 C, 1.1 KV grade, XLPE/PVC, armoured Copper Cablesfrom Panel to Starter including laying, jointing, terminations, etc. all complete.
1151)70 Sq mm
116Earthing: Earthing with copper earth plate including accessories and providing masanory enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc. with charcoal / coke and salt as required conforming IS:3043.
117Supply, installation, erecting and commissioning of Lightening Arrestor, 2 nos First Aid Box, 2 Nos Fire Extinguisher, 2 nos. rubber matting, etc for pump house.
118Lifting Equipments :- Supply, installation, erecting and commissioning of 3 Ton triple spur gear type chain pulley block ISI marked and travelling trolley with 6 m lift both tested for 50 % overload as per IS 3832.
119Tansformer Installation: Cost of construction of DP structure in Rail / RSJ Pole for above mention transformer with different type of MS channels, M.S. angles, brackets, insulators, AB Switch, three set of horn gap fuse, DO fuse, disc & pin insulator, lightening arrester with earthing, stay sets, nut bolts, fabrication work required for the job, cost of earthing of transformer (Two nos., one no. for neutral and one for body) with all required material, technicians, labours, Grouting, PCC work, fencing, Danger board, testing of transformer oil, fitting, fixing, connecting with HT/LT lines, etc. forpower supply, etc. all complete as per I.E. rules and specification of Jharkhand state electricity board.
120Twin Type Staff Quarter - 1 Unit (Please refer to Section 5, Sl. 2.7 of SBD)
121E/W in Excavation in foundation trenches inordinary soil (Vide classification of soil Item -A) & disposal of excavatd earth obtained to a distance up to 50 M including all lift leveling ramming the foundation trenches removing root of trees scrubs all complete as per approveddesign.
122Providing, coarse clean sand in filling in foudation trenches /in Plinthincluding ramming & watering in layers not exceeding150 mm thick with all leads lift including cost of all materilas, labour, royalty & taxes all complete as per building specification & direction of E/I
123Providing designation 75 A one brick flat soiling jointsfilled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I
124Providing P.C.C M-100 in nominal mix of (1:3:6) in foundation with appoved quantity of stonemetal (50 mm 25 mm dia size)graded& clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cementconcrete in mixer & placing in position, vibrating, striking, curing taxes & royalty all complete as per building specification& direction of E/I.
125Providing designation 75 A brick work in C.M. (1:6) in foundation7 Plinthwith approvedqualityof clean coarse sand of F.M 2 to 2.5 including Providing 10 mm thick mortar joints, Cost of screening, materials, Scaffolding, rakingoutjoints to 15 mm depth curing, taxes & royalty all complete as perbuildingspecification & direction of E/I
126Providing 50 mm thick damp proof coarse with cement concreteM-150 with nominal mix of (1:2:4) with approved quality of stone chips of 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to3 including screening, shuttering mixing cement concretein mixer with 5% cico or any other approved water proffing compound and placing in position, vibrating, striing, curing, taxes & royalty all completeas per building specification & direction of E/I
127Providingdesignation 75 A brick workin C.M (1:6) in super structure with approvedqualityof clean coarsesand of F.M. 2 to 2.5 including providing10 mm thick motar joints, cost of screening, materials, scaffolding, raking outjoints to 15 mm depth curing, taxes & royalty all complete as perbuilding specification & direction of E/I.
128Providing R.C.C M-150 with nominal mix of (1:2:4) in lintel level with approved quality of stonechips 20 mm to 6mm size graded & clean coarse sand of F.M 2.5 to including screening, centring,shuttering andmixing cement concrete in mixer& placing in position vibrating striking curing (butexcluding the cost of reinforcement) taxes & royalty all complete as per building specification of E/I.
129Centering & Shuttering
130Providing average 63 mm thick R.C.C M -200with nominal mix (1:1.5:3) chajja in shelves with approvedqualityof stone chips20 mm to 6 mm size graded & clean coarse sand of F.M 2.5 to 3 including making drip coursein concrete, screening, centering shuttering & mixing cement concrete in mixer & placing in position vibrating, striking, 6 mm cementplaster (1:4) in celling & sidesof chajja with sand of F.M 1.5, Curing (But excluding the cost of reinforcement) taxes and royalty all complete as per building specification of E/I.
131Centering & Shuttering
132Providing R.C.C M-200 with nominal mix of (1:1.5:3) in roof slab with approved quality ofstone chips 20 mm to 6 mm size Graded & Clean coarse sand F.M 2.5 to including making drip course in cocrete,screening, concreting, shuttering, centring mixing cement concrete in mixer & placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes & royalty all complete as per building Specification & direction of the E/I.
133Centering & Shuttering
134Supplying fitting & fixing good quality, well dressed & well seasoned sal wood work in choukhat in doors, windows, skylights, fan light and C/W celestial windows openings, including wedge over all clamps completeincluding application of two coats of wood preservative of approved quality on the surfacebutting walls & lintels all complete as per building specification & directionofE/I
135Supplyingfitting and fixing 250 x20 x 6 mm L-type M.S Clamp properly fish tailed .including making holes and setting the same in 375 x 125 x 75 mm cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and diection of E/I.
136Supplying all materials, labours and fitting & fixing 38 mm (1.5) thick good quality seasonedsal wood battened shutter ledged & braced in door and windows with oxidized iron fitting such as hingles, sliding door bolts, tower bolts, handles or ings hooks and eye, cleats, sand block as per schedule, taxes & royalty all complete as perbuilding specification & direction of Engineer -in- charge
137Supplying, fittings & fixing M.S Gril made of 20 x 6 mm M.S flat as perapproved design& drawing properly fabricated with jointscontinous filllet welded and finshed smooth, carriage of grill to worksite hoistingas per the building specification and direction ofE/I (where materials is not supplied by the Deptt.)
138Providing 40 mm thick pre cast R.C.C M-150 with nominal mix of (1:2:4) in jali with approvedquality to stonechips of 6mm nominal size and clean coarse sand of FM 2.5 to 3 with 1.6 mm thick M.S wire as per approveddesign and drawingand placing the same in position true to plumb and level and properly groutedwith cement mortar (1:3) including cost of curing, Scaffolding and finishing all complete as per building specification and direction E/I
139Providing and fixing fan hook of 16 mm dia M.S bar 1 meter long bent to reqiredsize and shape placedin position and fixing in R.C.Cslab/beam at the time of casting all complete as per building specification of E/I where material is not supplied by cheet
140Supplying, fitting and Fixing M.S Grill gate made of 20 x 6 mm M.S or 16 mm M.S raurbar Flat fitted on25 mm x 25 mm x 6mm M.S angle frame of size 60 x 60 x 6 as per approved design including cost of fabrication & drawing, properly fabricated with jointscontinuousfillet welded & finished smooth, providing necessary locking arrangements with Haskell &dummy duly fixed in C.C (1:2:4) blocks of reuired size applying a priming red lead paintsover steel works, taxes , carriage of grill to work site, as per the building specification & direction of E/I (wherematerialsis not supplied by the Dept)
141Providing 6 mm thick cement plaster (1:4) in cellingwith approved quality of clean coarse sandof F.M1.5 includingscreening, curing with allleads & lifts of water, scaffolding, taxes & royalty all complete as per building specification & direction of E/I
142Providing 12 mm thick cement plaster (1:6) with approved qualityof clean coarse sand of F.M 1.5 includingscreening Curing with all leads & lifts of water, Scaffolding, taxes 7 royalty all complete as per building specification & direction of E/I.
143Providing cement 1:3 (12mm ) plaster with cement mortar (1:3) using clean coarse sandfinishing with neat punning a dado 6" (150 mm) higha side room and out side wall upto plinth level includng screening, curing with all leads & lifts of water, scaffolding, taxes and royaltyall completeas per buildingspecification & direction of E/I
144Filling in foudation trenches & Plinth in layersnot exceeding 150 mm thick well watered, rammed, fully compacted & finedressed with earth obtained fromexcavation of foundationtrencheswithin a lead of 50 m & lift of 1.5 m all complete as per building specification & direction of E/I. (Mode of measurementcompacted volume)
145Providing average 150 mm thick dry rammed khoa beaten to 112 mm. (compacted with water) made of well burnt or jhama bricks including ramming properly till compacted thickness is achieved, curing & carriage of water with all leads, making proper slope & blending the top with cement mortar (1:10) all complete as per building specification & direction of E/I.
146Providing 25 mm thick First class patent stone flooring (1:2:4) with stone chips in two layers ,bottom layer 19 mmthick (1:2:4)with 12 mm to 6 mm size graded stone chips and top layer 6 mm thick (1:2) with 6 mm down stone chips in pannels including cost of curing , finishing the surface smooth by rubbing with carborandum stone taxes & royalty with all completeas per building specification & direction of E/I
147Providing designation 75 A one brick on edge flooring in C.M (1:4) with top surface flush pointed in CM (1:4) approvedquality of clean coarsesand of F.M 2 to 2.5 including the cost of screening, raking outjointsto 15 mm depth, curing taxes, royalty all complete as per building specification and direction (E/I)
148White washing three coat over new surface with approved quality of lime including cost of cleaningsurface thoroughly and removing the scales of smoke & ash marks with jhama rubbing, scaffolding washing of floor sand taxes all complete as per building specification and direction of E/I
149Providing all materials, labours & doing 2 (two) coat colour washing over a coat of white washing over new surface with approved quality of lime & colour over the new surface including the cost of clening surface thoroughly and removing the scales of smoke & ash marks with jhama rubbing, scaffolding washing of floor sand taxes all complete as per building specification and direction of E/I.
150Providing two coats of painting with readymix paint synthetic enamel paint over a coat of primer of approved shad and make over new wooden surface after cleaning, removing dirt scales, smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification & direction of E/I.
151Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust, dirt, scales, smokes and grease and cleaningthe surface thouroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I
152Providing 2(two) coats of Paniting with ready mixed paints of approved shade & make over steel surafce including cleaning the surface thouroughly, scaffolding & taxes all complete as per building specification & direction of E/I
153Providing 10 mm (TMT) Fe 500 TOR for steel reinforced as per approved design and drawing excluding carriage of torrod to work site including cutting bending and binding with annealed wire with cost of wire with cost of wore removal of rust placing the rods in position all complete as per building specification and direction of E/I.
154Carriage of materials from divisional store or kiln site or quarry site to work site including contract profit, loading, unloading, transportation, etc. all complete .
155Cement 10KM lead
156Steel10KM lead
157Sand 36KM lead
158Bricks 06KM lead
159Stone/Stone Chips11 KM lead
160Water Supply Sanitation Installation (Plumbing work)
161Supplying and laying GI pipes of approved make in trenches with red lead and yarn with socket and screw joints and cutting pipes in size and threading ends where necessary including carriage of materials up to work site etc. all complete as per specification and direction of E/I.
162i) 25mm GI. Pipe.
163ii) 15 mm GI. Pipe.
164Supplying materials and labours for fixing GI Pipes with red lead paints and yarn with screwed and sockted joints on wall, celling and floor including supplying of wall hooks of pipe clamp, wooden plugs, cutting pipe to size and threading ends where necessary all complete as per specification and direction of E/I.
165i) 15 mm GI. Pipe
166Supplying, fitting and fixing of GM ferrule of approved make in DI/CI main including drilling and tapping CI/DI main etc. all complete as per specification and direction of E/I.
167Supplying and fixing GI fittings of approved make all complete as per direction of E/I.
168(a) Elbow 15 mm dia
169(b)     Tee plane 15mm dia
170(c)     Nipple 15mm dia.
171(d)     Union Socket 25mm dia
172(e)     Union Socket 15mm dia
173(f)      Brass bib cock15mm dia
174(g)     C.I stop cock 15mm dia
175(h)     C.I. stop cock 25mm dia
176(i) Reducing Socket 25x15mm
177(j)  Tee 25x25x15mm dia
178Supplying, fitting and fixing vitreous white glazed earthen were I W C of parry Hindustan or any other I.S.S approved make with 100 mm HCI ‘P’ trap, 15 Liters CI pull and let go flushing cistern of names or otherISS equivalent make complete with all fittings C.I. or C.C brackets, 32 mm, alkathene /PVC telescopic flush pipe about 2 mtrs. long with one brass coupling and clamps, GI chain and pull including supplying and fixing a pair of vitreous white glazed earthen were footrest to be fixed in floor, 15 mm .CI body brass spindle, stop cock of weight not less than 50 grams, 15 mm. PVC connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. (510mm.long with 12.5 Liter low level PVC System).
179SEPTIC TANKand SOAK PIT
180Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item - B) and disposal of excavated earth as obtained to a distance up to 50 m including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubsall complete as per approved design, building specification and direction of E/I.
181Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I.
182Providing designation 75A one Brick flat soling, joints filled with local sand including cost of watering, tax, royalty all complete as per building specification and direction of E/I.
183Providing P.C.C M150 with nominal mix of (1:2:4) in foundation with approved stone chips 20mmto 6mm size well graded andclean course sand of FM-2.5to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, Vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
184Providing water proof cement plaster (1:3) with clean course sand of F.M- 1.5mm with 5% cico or any other approved water proofing compound including taxes and royalty all complete as per buildingspecification and directions of E/I.
185(a)     19 mm thick
186(b)     12 mm thick
187Providing designation 75A bricks work in C.M. in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints, cost of screening materials racking out joints to 15 mm. depth, curing taxes and royalty all complete as per building specification and direction of E/I.
188(a) B/Win C.M (1:4)
189(b) B/W 75-B in (1:6) for Soak pit
190(c) Brick work in dry masonry for soak pit.
191Providing pre cast R.C.C.M-150 with nominal mix of (1:2:4) slab of desired sizewith approved quality of stone chipsand clean coarse sand of FM 2.5 to 3 including curing, shuttering, carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement), taxes and royalty etc. all complete as per building specification and direction of E/I.
192Providing for reinforcement as per approved design and drawing excluding carriage of tor rod to work site including cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per Specification and direction of E/I.
19310 mm dia
194Supplying fitting and fixing H.C.I. Pipe/ H.C.I. fitting of Approved make confirming to I.S.S 1729 including supplying nails and bobbins lead andyarn from making lead caulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/I.
195(a)        100mm dia H.C.I. Tee.
196(b)       100mm dia H.C.I. Band
197(c)        50mm dia H.C.I. Cowel
198(d)       50mm dia H.C.I. Vent pipe
199(e)        100mm H.C.I. Pipe
200Supplying materials and labours and fixing20mm dia M.S bar steps in wall of 0.3 m interval and staggeredin (1:2:4) cement concrete including scaffolding and curing etc. all complete as per specification and direction of E/I.
201Supplying all materials, labours, tools and tackles and 100mm dia R.C.C hume pipe and laying jointing, testing, earth work including carriage of materials etc. all complete.
202Supplying 50mm size brick bats and filling in soak pit including carriage and labours etc. all complete as per direction of E/I.
203Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600x450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x475mm G.I. Cover With frame (Weight not less than 36 Kg.) along with earth work in excavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I
204Carriages of materials
205(a)     Brick – 06 KM lead
206(b)     Sand - 36 KM lead
207(c)     Stone chips - 11 KM lead
208(d) Steel -10 KM lead
209(d)     Cement-10 KM lead
210Electrical Works
211Point wiring in PVC conduit with modular type switch wiring for light point /fan point with 1.5sqmm F.R. PVC insulated copper conductor single core cable in surface/ recessed PVC conduit with modular switch modular plate, suitable G.I. box and the point with sqmm FR PVC insulated copper conductor single core cable etc as required
212Wiring for twin control light point with 1.5 sqmm F.R. PVC insulated copper conductor single core cable in surface/recessed PVC conduit with two way modular switch modular plate, suitable G.I. box and the point with sqmm FR PVC insulated copper conductor single core cable etc as required
213Wiring for light /power plug point with 2 x 4 sqmm F.R.PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with one no 4 sqmmFR PVC insulated copper conductor single core cable for loop earthing etc as required.
214Coppersub main wiring in PVC conduit Wiring for sub main wiring withPVC insulated copper conductor single corein surface/recessed PVC conduitas required.
2152 x 1.5 sqmm + 1 x 1.5 sqmm earth wiring
2162 x 2.5 sqmm + 1 x 2.5 sqmm earth wiring
217Supplying and fixing following way three pole and neutral sheet MCB distribution board 415 volts on surface/ recessed complete with tinned copper bush bars, neutral link, earth bar, din bar, detachable gland plate inter connection phosphatised and power painted including earthing etc as required (but with out mcb / rccb / Isolator) (4+12) double door horizontal type.
218Supplying and fixing 5 amp to 32 amp, rating 240 volts, B series miniature circuit breaker of single poles in existing MCB DB complete with connecting, testing, and commissioning etc as required
219Earthing with G.I. earth pipe 4.5 M long 40mm diaincluding accessories and providing masonry enclosure withcopperplate having locking arrangement and watering pipe etc with charcoal, salt all complete as per electrical rule
220Supplying ,fitting and fixing following sizes of PVC conduct along with accessories in surface / races including cutting the wall and making good the same in case of recessed conduit as required
221PVC con 20 mm PVC pipe
222PVC con 25 mm PVC pipe
223Installation commissioning and testing Ceiling Fan
224Carriage of ceiling fan and regulator
225Supplying, fitting and fixing 5 amp ceiling rose on the existing junction
226Supplying, fitting and fixing breas batten/ angle holder including connection etc.
227Supplying, fitting and fixing G.I. box with modular plate and cover in front of surface or in recess including providing and fixing 3pin 5/6 amp modular type switch, connection, painting etc as required.
228Supplying, fitting and fixing G.I. box with modular plate and cover in front of surface or in recess including providing and fixing 6pin 5/6 amp and 15/16 amp socket outlet and 15/16 amp modulartype switch, connection, painting etc as required.
229Supplying and drawing co-axial T.V. cable RG-06 grade 0.7 nn solid copper conductor PE insulated seilded with fine tinned cover braid and protected with PVC sheath in the existing surface / recessed steel/ PVC conduit as required.
230Supplying and fixing modular switch / socket on the existing modular plate and switch box including connection but excluding modular plate etc,as required. TV antenna socket out put
231Supplying, fitting and fixingmodular base andcover plate on existing modular metal boxes etcas required.
232Cost ofEarthing with G.I. earth pipe 4.5 M long 40mm diaG.I.Pipe 600 mm x 600 mm x 6 mm thick copper earth plate and 8 SWG copper wire including cost of making 1.2 x 1.2 x 3m deep pit and filling with charcoal, salt all complete as per electrical rule
233Boundry Wall for WTP & 2 Nos. ESR. (509.20 M Long)
234Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority Construction of Compound wall. etc. all complete job. (Please refer to Section 5,Sl. 2.9 of SBD)
235Earth work in excavation in foundation trenches in hard soil (Vide classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.
236Providing coarse clean sand in filling in fundation trenches or in plinth including ramming and watering in layers not exceeding 15mm thick with all leads and lifts includiing cost of all materials, labour, royality and taxes all complete as per building specification and direction of E/I.
237Providing designation of 75A one brick flat soling, joints filled with local sand including cost of watering, taxes royalty all complete as per building specification and direction of E/I.
238Providing P.C.C M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone chips (20 mm to 6 mm size)clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
239Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in foundation with approved quality of stone chips (20mm to 6mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
240Centering & Shuttering
241Providing RCC M-200 with nominal mix of (1:1.5:3) in stiffeners with approved quality of stone chips 20mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I.
242Centering & Shuttering
243Providing RCC M-200 with nominal mix of (1:1.5:3) in band at plinth level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I. Top of Wall
244Providing RCC M-200 with nominal mix of (1:1.5:3) in band at lintel level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I. Top of Wall
245Centering & Shuttering
246Providing designation 75 A brick work in CM (1:6) in super structure with approved quality of clean coarse sand of FM 2 to 2.5 including, providing 10mm thick mortar joints cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
247Providing 12mm thick cement plaster (1:6) with clean coarse sand of FM 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direction of E/I.
248Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per buildingspecification & direction of E/I. Qnty. Same as Item no.13
249Providing Tor steel reinforcement of 10 mm,12 mm, &16 mm dia Bars as per approved design and drawing excluding carriage of M.S bars to work site, cutting, bending and binding with annealed wire with cost of wire ,removal of rust, Placing the rods in position all complete as per building specification and direction of E/I.
250Filling in foundation trenches and plinth in layers not exceeding dressed with earth obtained from excavation of foundation trenches with a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I.
251Carriage of materials from divisional store or kiln site or quarry site to work site including contractor"s profit, loading, unloading, transportation etc. all complete .
252Cement10KM lead
253Steel 10KM lead
254Sand 36KM lead
255Stone/Stone Chips11KM lead
256Bricks 06KM lead
257Gate - 03 Nos.
258Earth work in excavation in foundation trenches in hard soil (Vide classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.
259Providing coarse clean sand in filling in fundation trenches or in plinth including ramming and watering in layers not exceeding 15mm thick with all leads and lifts includiing cost of all materials, labour, royality and taxes all complete as per building specification and direction of E/I.
260Providing designation of 75 A one brick flat soling, joints filled with local sand including cost of watering, taxes royalty all complete as per building specification and direction of E/I.
261Providing P.C.C. M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone chips (20 mm to 6 mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
262Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in foundation with approved quality of stone chips (20mm to 6mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
263Centering & Shuttering
264Providing RCC M-200 with nominal mix of (1:1.5:3) in column with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I.
265Centering & Shuttering
266Providing RCC M-200 with nominal mix of (1:1.5:3) in band at plinth level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I. Top of Wall
267Centering & Shuttering
268Providing Tor steel reinforcement of 10 mm, 12 mm & 16 mm dia Bars as per approved design and drawing excluding carriage of M.S bars to work site, cutting ,bending and binding with annealed wire with cost of wire, removal of rust, Placing the rods in position all complete as per building specification and direction of E/I.
269Filling in foundation trenches and plinth in layers not exceeding dressed with earth obtained from excavation of foundation trenches with a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I.
270Supplying fitting & Fixing M.S. grill gate with M.S. grills made 20x6mm M.S. flat or 16mm M.S. square bars fitted 25 x 25 x 6 mm M.S. angle frame of size 60x60x6 mm including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
271Providing two coat of painting with ready mixed paint of approved shade and make over steel surface
272Carriage of materials from divisional store or kiln site or quarry site to work site including contractor"s profit, loading, unloading, transportation etc. all complete .
273Cement10KM lead
274Steel10KM lead
275Sand36KM lead
276Stone/Stone Chips11KM lead
277Bricks06KM lead
278Raw Water Rising main.
279Providing and Supplying ISI mark Confirming to IS-8329/ 2000 centrifugally cast (spun) DI pipe for water works with socket and spigot ends in standard working lengths of 4.5, 5.5 & 6 m for classification K-9 suitable for push on joint (Rubber gasket D Jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating (including cost of one gasket for each pipe) Note: - Rates are F.O.R. Jharkhand but excluding of GST.
280DI K-9, Dia 200 mm
281Providing and supplying ISI standard DI specials & fittings with sealing rubber gasket of SBR, complete with cast iron follower gland and MS nut bolts coated or otherwise protected from rusting and suitable for DI Pipes complete as per IS - 9523 Class K-12. Note: - Rates are F.O.R. Jharkhand but excluding of GST.
282Providing Double Flanged Sluice valve confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps including all transportation etc. complete. (without bypass Arrangement ) PN 1.6
283Sluice valve,Dia 200 mm
284Scour valve,Dia 150 mm
285Providingandsupplyingair valvesasperIS-14845-2000 andM J P"s Standard specificationsof approved make and quality of following diameters including all taxes (central and local ) , railway friegth, insurancethird party inspection charges loading unloading transportation up to departmental store/site etc.complete .P.N 1.6
286Air Valve SingleBall Flanged / screwed type 40 mm dia
287Earthwork in excavation (as per I.S. 3114/1965 for laying of different type and sizes of pipe so as to give one meter avarage cover over the socket of pipe with disposal of excavated with in initial lead and lift as per specification and direction of engineer-in charge.
288Excavation in Soil item-B
289Earth Work in excavation of foundation trenches as perdesign section in ordinary soft rock (Vide classification of soil item - C) and disposal of excavated materials so obtained (50 M away from the edge of the trenches) with initial lead of 10 M and initiallift of 1.5 m as per specification and direction ofE/I in ordinary of soft rock (where blasting is not reqired) Balance 10% of total Earthwork of taken classification soil item - C.
290Excavation in Soil item - C
291Supplying labours, tools and tackles, lubricant etc. for laying and jointing C.I.S/S tyton pipes (class LA) trenches supplyingrubbergasket(Rubbergasket confirmingto I.S.S.-5382-1969) and making gasketjoint including providing night guard, barrier and red light to safe guard against accident, all complete (Pipe to be supplied departmentally free of cost andlaying of pipes is to be done as per I.S.S.3114-1985) as per design,specification and direction of E/I.
292DI K-9, Dia 200 mm.
293Lowering & laying and fixing in proper alignment and position all types of CI air valve as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all materia and giving satisfactory hydraulic testing etc. complete. (for all class of valves)
29440 mm dia.
295Supplying Labour and tools for fixing C.I. sluice valve in trenches with a pair of C.I. Tail piece including makinglead caulked joints and flanged joints as per I.S.S. specification, including supplying all jointing materials (Piglead confirming to I.S.S. 782-1978, yarn confirming to I.S.S. 6587–1972 and nuts and bolts confirming to I.S.S. 1364–1983) including drilling holes in flanges if required as per specification and direction of E/I. (Sluice valve and pieces to be supplied departmentally free of cost).
296Sluice valve,200 mm dia
297Scour valve,150 mm dia
298Earthwork in backfilling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-charge.
299Supplying labours, tools and tackles for testing of laid CI pressure pipe upto 60m head of water all complete as per specification and direction of E/I. (Water to be supplied free of cost departmently)
300DI K-9, Dia 200 mm.
301Labour charge for one cutting ofC.I/ D.I and specials including suppying supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I.
302DI K-9, Dia 200 mm.
303Supplying all materials, labours, tools and equipment and constructing brick masonry chamber of 1.50 M.x 1.20 M. x 1.50 M. inner size having 25 cm. thick 75 A brick masonry wall in C.M. (1:6), over 150 mm. P.C.C. M- 150, laid over one brick flat soling on 100mm. local sand filling, including 12 mm. thick cement plaster with punning of inner surface and exposed surface of B/W in C.M. (1:6) and R.C.C. M- 150 cover slab 150 mm. thick with 20 mm. to 6 mm. gradedstone chips, and clean coarse sand of F.M. 2.5 to 3 including providing CI surface box and screening shuttering, mixing, placing, striking, curing, taxes and royalty all complete as per approved design, drawing & specification and direction of E/I.
304Providing P.C.C. M-150 with nominal mix of (1:3:6) in foundation with approved qualitystone metal(20 mm to 6 mm Size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of Engineer -in charge
305A) Thrust Block
306200 mm dia.
307ClearWater Rising main.
308Providing and Supplying ISI mark Confirming to IS-8329/ 2000 centrifugally cast (spun) DI pipe for water works with socket and spigot ends in standard working lengths of 4.5, 5.5 & 6 m for classification K-9 suitable for push on joint (Rubber gasket D Jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating (including cost of one gasket for each pipe) Note: - Rates are F.O.R. Jharkhand but excluding of GST.
309DI K-9, Dia 150 mm
310DI K-9, Dia 150 mm
311DI K-9, Dia 200 mm
312Providing and supplying ISI standard DI specials & fittings with sealing rubber gasket of SBR, complete with cast iron follower gland and MS nut bolts coated or otherwise protected from rusting and suitable for DI Pipes complete as per IS - 9523 Class K-12. Note: - Rates are F.O.R. Jharkhand but excluding of GST.
313Providing Double Flanged Sluice / NR / Scour valve confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps including all transportation etc. complete . (without bypass Arrangement ) PN 1.6
314Sluice valve,150 mm dia.
315Sluice valve,150 mm dia.
316Sluice valve,200 mm dia.
317N R valve,200 mm dia. ( PN 1.6)
318Scour valve,150 mm dia.
319Providingandsupplyingair valvesasperIS-14845-2000 andM J P"s Standard specificationsof approved make and quality of following diameters including all taxes (central and local ) , railway friegth, insurancethird party inspection charges loading unloading transportation up to departmental store/site etc.complete .P.N 1.6
32025 mm dia. (Single Ball Flang. Type Air Valve P.N 1.6)
32132 mm dia. (Single Ball Flang. Type Air Valve P.N 1.6)
322Earthwork in excavation (as per I.S. 3114/1965 for laying of different type and sizes of pipe so as to give one meter avarage cover over the socket of pipe with disposal of excavated with in initial lead and lift as per specification and direction of engineer-in charge.
323Excavation in Soil item-B
324Earth Work in excavation of foundation trenches as perdesign section in ordinary soft rock (Vide classification of soil item - C) and disposal of excavated materials so obtained (50 M away from the edge of the trenches) with initial lead of 10 M and initiallift of 1.5 m as per specification and direction ofE/I in ordinary of soft rock (where blasting is not reqired) Balance 10% of total Earthwork of taken classification soil item - C.
325Excavation in Soil item - C
326Supplyinglabours,toolsandtackles,lubricantetc.for laying and jointing C.I.S/S tyton pipes (class LA) trenches supplyingrubbergasket(Rubbergasket confirmingto I.S.S.-5382-1969) and making gasketjoint including providing night guard, barrier and red light to safe guard against accident,allcomplete(Pipetobesupplied departmentally freeofcostandlayingofpipesistobe done asperI.S.S. 3114-1985)asperdesign, specification and direction of E/I
327DI K-9, Dia 150 mm.
328DI K-9, Dia 150 mm.
329DI K-9, Dia 200 mm.
330Lowering & laying and fixing in proper alignment and position all types of CI air valve as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all materia and giving satisfactory hydraulic testing etc. complete. (for all class of valves).
33125 mm dia.
33232 mm dia.
333Supplying labour and tools for fixing C.I. sluice valve in trenches with pair of C.I. Tail piece including making laed caulked joints and flanged joint as per I.S.S. specification including supplying all jointing material (pig lead confirming to I.S.S 782-1978, yarn confirming to I.S.S. 6587-1972 and nuts and bolt confirming to I.S.S. 1364-1983) including drilling holes in flanges if required as per specification and direction of E/I.
334Sluice valve,150 mm dia.
335Sluice valve,150 mm dia.
336Sluice valve,200 mm dia.
337N R valve,200 mm dia. ( PN 1.6)
338Scour valve,150 mm dia.
339Earthwork in backfilling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-charge.
340Supplying labours, tools and tackles for testing of laid CI pressure pipe upto 60m head of water all complete as per specification and direction of E/I. (Water to be supplied free of cost departmently)
341Dia 150 mm.
342Dia 150 mm.
343Dia 200 mm.
344LabourchargeforonecuttingofC.I/D.Iandspecials including suppying supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I.
345Dia 150 mm.
346Dia 150 mm.
347Dia 200 mm.
348Supplying all materials, labours, tools and equipment and constructing brick masonry chamber of 1.50 M.x 1.20 M. x 1.50 M. inner size having 25cm. thick 75 A brick masonry wall in C.M. (1:6), over 150 mm. P.C.C. M- 150, laid over one brick flat soling on 100mm. local sand filling, including 12 mm. thick cement plaster with punning of inner surface and exposed surface of B/W in C.M. (1:6) and R.C.C. M- 150 cover slab 150 mm. thick with 20 mm. to 6 mm. gradedstone chips, and clean coarse sand of F.M. 2.5 to 3 including providing CI surface box and screening shuttering, mixing, placing, striking, curing, taxes and royalty all complete as per approved design, drawing & specification and direction of E/I.
349Providing P.C.C. M-150 with nominal mix of (1:3:6) in foundation with approved qualitystone metal(20 mm to 6 mm Size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of Engineer -in charge
350A) Thrust Block
351150 mm dia.
352150 mm dia.
353200 mm dia.
354Providing, installing and giving satisfaction field testing of flanged ends Bulk water meter of following type and as mentioned below in (a) and (b) with FGI - 250 cast iron body, class "B" confirming to I.S. 2373 or as per ISO 4064, marked to read in metric system, along with manufacturer"s test and guarantee certificate including cost of all material with ISI mark or EEC mark Enclosed type as per IS2373.
355Dia 200 mm.
356DISTRIBUTION MAIN
357Earthwork in excavation (as per I.S. 3114/1965 for laying of different type and sizes of pipe so as to give one meter avarage cover over the socket of pipe with disposal of excavated with in initial lead and lift as per specification and direction of engineer-in charge.
358Excavation in Soil item-B
359Earth Work in excavation of foundation trenches as perdesign section in ordinary soft rock (Vide classification of soil item - C) and disposal of excavated materials so obtained (50 M away from the edge of the trenches) with initial lead of 10 M and initiallift of 1.5 m as per specification and direction ofE/I in ordinary of soft rock (where blasting is not reqired) Balance 10% of total Earthwork of taken classification soil item - C.
360Excavation in Soil item - C
361Cutting the road as well as restoring the same as per specifications and as directed by Engineer incharge
362Pucca Road (Except black top only taken out material to be used)40%
363Waterbound Macadam road(taken out material will be used) for cutting as per requirement 30% of the restoring work
364Dismantaling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15 meter lead and disposal of unservisible materials with all leads complete as per direction of E/I
365Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of store chips 20 mm-6 mm size graded and clean coarsed sand of FM 2.5 to 3.0 including screeing shuttering mixing cement concrete in mixer and placing in position vibrating striking curing taxes and royalty alll complete as per building specification and directio of E/I.
366Earthwork in backfilling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-charge.
367Providing and Supplying ISI mark Confirming to IS-8329/ 2000 centrifugally cast (spun) DI pipe for water works with socket and spigot ends in standard working lengths of 4.5, 5.5 & 6 m for classification K-7 suitable for push on joint (Rubber gasket D Jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating (including cost of one gasket for each pipe) Note: - Rates are F.O.R. Jharkhand but excluding of GST.
368DI K-7, Dia 100 mm
369DI K-7, Dia 150 mm
370DI K-7, Dia 200 mm
371DI K-7, Dia 250 mm
372HDPE Pipe, Dia 110 mm (PE - 100, PN - 10)
373(a) Providing and supplying ISI standard DI specials & fittings with sealing rubber gasket of SBR, complete with cast iron follower gland and MS nut bolts coated or otherwise protected from rusting and suitable for DI Pipes complete as per IS - 9523 Class K-12. Note: - Rates are F.O.R. Jharkhand but excluding of GST.
374(b) Special for HDPE Pipe
375Supplyinglabours,toolsandtackles,lubricantetc.for laying and jointing C.I.S/S tyton pipes (class LA) trenches supplyingrubbergasket(Rubbergasket confirmingto I.S.S.-5382-1969) and making gasketjoint including providing night guard, barrier and red light to safe guard against accident,allcomplete(Pipetobesupplied departmentally freeofcostandlayingofpipesistobe done asperI.S.S. 3114-1985)asperdesign, specification and direction of E/I
376DI K-7, Dia 100 mm.
377DI K-7, Dia 150 mm.
378DI K-7, Dia 200 mm.
379DI K-7, Dia 250 mm.
380HDPE, Dia 110 mm.
381Supplying labours, tools and tackles for testing of laid CI pressure pipe upto 60m head of water all complete as per specification and direction of E/I. (Water to be supplied free of cost departmently)
382DI K-7, Dia 100 mm.
383DI K-7, Dia 150 mm.
384DI K-7, Dia 200 mm.
385DI K-7, Dia 250 mm.
386HDPE, Dia 110 mm.
387LabourchargeforonecuttingofC.I/D.Iandspecials including suppying supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I.
388DI K-7, Dia 100 mm.
389DI K-7, Dia 150 mm.
390DI K-7, Dia 200 mm.
391DI K-7, Dia 250 mm.
392HDPE, Dia 110 mm.
393Providing Double Flanged Sluice valve confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainlesssteel spindle, caps including all transportation etc. complete. (without by-pass Arrangement-P.N-1.0). (With E.D)
394Sluice valve,Dia 100 mm
395Sluice valve,Dia 150 mm
396Sluice valve,Dia 200 mm
397Sluice valve,Dia 250 mm
398Sluice valve,Dia 100 mm
399Scour valve,Dia 100 mm
400Scour valve,Dia 150 mm
401Scour valve,Dia 200 mm
402Providing, installing and giving satisfaction field testing of flanged ends Bulk water meter of following type and as mentioned below in (a) and (b) with FGI - 250 cast iron body, class "B" confirming to I.S. 2373 or as per ISO 4064, marked to read in metric system, along with manufacturer"s test and guarantee certificate including costof all material with ISI mark or EEC mark Enclosed type as per IS2373. .
403200 mm dia
404250 mm dia
405Supplying labour and tools for fixing C.I. sluice valve in trenches with pair of C.I. Tail piece including making laed caulked joints and flanged joint as per I.S.S. specification including supplying all jointing material (pig lead confirming to I.S.S 782-1978, yarn confirming to I.S.S. 6587-1972 and nuts and bolt confirming to I.S.S. 1364-1983) including drilling holes in flanges if required as per specification and direction of E/I.
406Sluice valve,Dia 100 mm
407Sluice valve,Dia 150 mm
408Sluice valve,Dia 200 mm
409Sluice valve,Dia 250 mm
410Sluice valve,Dia 100 mm
411Scour valve,Dia 100 mm
412Scour valve,Dia 150 mm
413Scour valve,Dia 200 mm
414Supplying all materials, labours, tools and equipment and constructing brick masonry chamber of 1.50 M.x 1.20 M. x 1.50 M. inner size having 25cm. thick 75 A brick masonry wall in C.M. (1:6), over 150 mm. P.C.C. M- 150, laid over one brick flat soling on 100mm. local sand filling, including 12 mm. thick cement plaster with punning of inner surface and exposed surface of B/W in C.M. (1:6) and R.C.C. M- 150 cover slab 150 mm. thick with 20 mm. to 6 mm. gradedstone chips, and clean coarse sand of F.M. 2.5 to 3 including providing CI surface box and screening shuttering, mixing, placing, striking, curing, taxes and royalty all complete as per approved design, drawing & specification and direction of E/I.
415Coffer Dam
416Providing, constructing coffer dam in river basin/ dam storagesaspertypedesign includingexcavation, filling the middle portion with B.C. soil (in gunny bags if required). Providing impervious/semi impervious materials on both side of B.C. soil (in gunny bags if required) including ramming, compacting to satisfaction of Engineer-in-charge, tillthe completion of work including dismantling coffer dam after completionofworksand disposingoffmaterialas directed by the Engineer-in-charge.
417a) For Gangway
418b) For Intake well
419Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches,well works by using pumps and other devices including disposing off water to safe distance asdirected by Engineer-in-charge (including cost ofmachinery, labour, fuel etc. complete).
420a) For Gangway
421b) For Intake well
422House Connection for 3569 Nos. Consumer.
423Earth work in excavation (as per I.S.3114/ 1965 for laying of different types and sizes of pipes so as to give 1 m av. cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of E/l. (For soil item B)
424Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including" cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l. (Mode of measurement complacted volume).
425ProvindingP.C.C M-150 with in norminal mix of (1:2:4) in foundation with approvedquality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including, screening, shuttering, mixingcement concrete in mixture and placing in position vibrating striking curing taxes and royality all complete as per building specifiaction and direction of E/I.
426Centering & Shuttering
427Earth work in back fillingthe trenches after laying of different types and sizes of pipes with earth removed during excavation within initial lead and lift as per specification and direction of E/I. (For soil item A & B)
428Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
429Providing and supplying blue MDPE pipes confirming to ISO 4427:1996 manufactured from vergin resin PE 80 food grade compounded raw material having blue colour only assurance certificate from quality agencies like WRC / CIPET ( India) / DVGM / KIWA / SPGN etc. for usage in drinking water with quality system. The cost shall including cost all taxes, inspection charges transprotaion to work site and earth work involved, all complete job as per specification and direction of E/I. 20 mm dia pipe.
430Providing and supplying G.I. pipes (Tata and equivalent make) for usage in drinking water with quality system, The cost shall include testing of all materials all taxes central, State, Municipal, Inspection charges transportation up to site transite insurance, loading, unloading, stacking etc. complete as specified and directed.
431Lowering laying and jointing HDPE / MDPE pipe in proper position including all specials by Compression fitting / Electrofusion and But fusion jointing procedure including hydraulic testing as er relevent IS Code complete with all materials for jointing procedure like Electro-fusion machine, Electric mirrior/ heater/But fusion welding machine with hydraulic testing and all labours as directed by engineer in charge as per IS-7634 part II
432Supplying labour and tools for fixing G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketted joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of E/l. (Pipe with socket to be supplied deparmentally free of cost).
433Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dia ferrule weight not less than 425 gram
434Providing and fixing gun metal full way valve of approved quality all complete as per specification and direction of E/ (a) 20 mm dia and weight not less than 400 gram.
435Providing and fixing 15 mm Dia male ended C.I Body Brass Spindle valve and seat bib cock of approved quality (Wt.not Less than 400 gms.) with extra socket all complete as per specification and Direction of E/I.
436Supplying and fixing G.I. fittings of Approved make all complete as per specification and Direction of E/I
437Elbow 20 mm
438Elbow 15 mm
439Reducing Socket 20 mm
440Nipple 20 mm
441Nipple 15 mm
442Union Socket 20 mm
443Socket 15mm
444Socket 20 mm
445Carriage of materials
446Operation & Maintenance for Five years
447O/M work with Labour component & Materials for 1st Year
448As per SBD Section - 5 Clouse 9.10
449O/M work with Labour component & Materials for 2nd Year
450As per SBD Section - 5 Clouse 9.10
451O/M work with Labour component & Materials for 3rd Year
452As per SBD Section - 5 Clouse 9.10
453O/M work with Labour component & Materials for 4th Year
454As per SBD Section - 5 Clouse 9.10
455O/M work with Labour component & Materials for 5th Year
456As per SBD Section - 5 Clouse 9.10
45718% GST
458Labour cess
Disclaimer :