Tender For Repair/ Maintenance Of Dg Set Amf Panel, Ats And Other Connected Works At 901 Su Nathatop, Udhampur-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair/ Maintenance Of Dg Set Amf Panel, Ats And Other Connected Works At 901 Su Nathatop. Submission Date for this Tender is 10-12-2022. Diesel Generators Tenders in Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34918252
Tender For Repair/ Maintenance Of Dg Set Amf Panel, Ats And Other Connected Works At 901 Su Nathatop
Open Tender
Indian
Jammu And Kashmir
Udhampur
10-12-2022

Tender Details

Repair/ Maintenance Of Dg Set Amf Panel, Ats And Other Connected Works At 901 Su Nathatop

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR MAINTENANCE OF DG SET AMF PANEL ATS AND OTHER CONNECTED WORKS AT 901 SU NATHATOP
Sl. No. Item Description
1Servicing of DG SET Supply & fixingin repair/ replacement ofof the following spares / items for servicing ofDG Sets of capacity125KVAto 320 KVA capacity :-(125 KVA-1 No,160 KVA- 2 Nos, 180 KVA-2Nos, 250 KVA -2 Nos 200 KVA 01 Noand 320 KVA-2 Nos=10 Sets)
2Fuel filter for320 KVA DG Sets( Make : fleet guard / kirloskar )
3Fuel filter for250 KVA DG Sets ( Make : fleet guard / kirloskar )
4Fuel filter for200 KVA DG Sets ( Make : fleet guard / kirloskar )
5Fuel filter for180 KVA DG Sets ( Make : fleet guard / kirloskar )
6Fuel filter for160 KVA DG Sets( Make : fleet guard / kirloskar )
7Fuel filterfor 125KVADG Sets( Make fleet guard / kirloskar )
8Lubrication/Oil filter for 320 KVA DG Set( Make fleet guard / kirloskar )
9Lubrication/Oil filter for 250 KVA DG Set( Make fleet guard / kirloskar )
10Lubrication/Oil filter for 200 KVA DG Set( Make fleet guard / kirloskar )
11Lubrication/Oil filter for 180 KVA DG Set( Make fleet guard / kirloskar )
12Lubrication/Oil filter for 160 KVA DG Set( Make fleet guard / kirloskar )
13Lubrication/Oil filter for 125 KVA DG Set( Make fleet guard / kirloskar )
14Air filter for 320 KVA DG set ( Make fleet guard / kirloskar )
15Air filter for 250 KVA DG set ( Make fleet guard / kirloskar )
16Air filter for 200 KVA DG set ( Make fleet guard / kirloskar )
17Air filter for 180 KVA DG set ( Make fleet guard / kirloskar )
18Air filter for 160 KVA DG set ( Make fleet guard / kirloskar )
19Air filter for 125 KVA DG set ( Make fleet guard / kirloskar )
20Centrifugal filter Cat Part No.(160&180kva) F-602446000
21M&L for repair /overhaulingand calibration of FIP complete with replacement of worn out part such as copper washers, "O" Rings etc including calibration for the following DG Sets:-
22320 KVA DG Set
23250 KVA DG Set
24200 KVA DG Set
25180 KVA DG Set
26160 KVA DG Set
27125 KVA DG Set
28Dismantling, openingof complete radiator assemblyand supply and fixing of New radiator assamblyof 160KVADG Sets,nut, bolt, washer, radiator caps etc complete all as specified and directed by Engineer-in-Charge
29Dismantling, openingof complete radiator assemblyand supply and fixing of New radiator assamblyof 320 KVADG Sets,nut, bolt, washer, radiator caps etc complete all as specified and directed by Engineer-in-Charge
30Dismantling, opening and cleaning of complete radiator assembly of followingDG Sets, checking of water leakage, including upper and bottom tank cleaning of slots including welding/brazing where requiredand making 100 % leak proof and washingwith chemically anti corrosion /water solution by using jet pumping set and as well as cleaning manually by usingsteel wire brushes and removing all rust, silt /corrosive material and making good smooth functioning and upper & bottom tank gasket set, all rusted nut, bolt, washer, radiator caps etc complete all as specified and directed by Engineer-in-Charge
31320 KVA DG Set
32250 KVA DG Set
33200 KVA DG Set
34180 KVA DG Set
35160 KVA DG Set
36125 KVA DG Set
37M&L for complete servicing and overhauling of turbo charger along with replacement of kitcomplete for the following DG Sets:-
38320 KVA DG Set
39250 KVA DG Set
40200 KVA DG Set
41180KVA DG Set
42160 KVA DG Set
43125 KVA DG Set
44Supply and fixingin replacement of flywheel gear ring, oil seal, crank ring of DG Set of capacity180/160 KVA complete all as specified and directed.
45Dismantling the defective charging dynamo of 24 Volt DC, cleaning with cleaning agent, over hauling, lubricating and replacement ofArmature assembly ,Bearings of any description,Field coil etc all as directed for following DG sets.
46320 KVA DG set
47250 KVA DG set
48200 KVA DG set
49180 KVA DG Set
50160 KVA DG Set
51125 KVA DG Set
52Disconnecting and dismantling the unserviceable self starter assembly by removing the all bolts and nuts and disconnecting from DG sets of capacity 160/180/125/200/250 KVA and 320 KVA , opening of self starter, overhauling of self starter, replacement ofworn out bearing, bushes, field coil etc reconnecting, testing and commissioning complete all as specified and directed byEngr-in-Charge.
53Disconnecting & dismantling the alternator unit of 250/180/160 /320KVA DG SET (Make-KIRLOKAR) further separating armature from stator carefully cutting and taking out burnt winding of rotor, cleaning the slots and checking for defective stampingsand replacing the same with the new stampings made out of silicon steel of same size and thickness duly applying the insulation and assembling the stampings inserting in position in the rotor including applying start insulation and complete re-winding the alternator for winding with super enameled copper inding of same gauge and same number of turns as per existing, including replacement of carbon brushes, tapping the winding and bringing out the coil connections for 3 phase, 415 volts, 50 Hz AC supply pre heating the winding proper insulation material, varnishing and drying the winding in over including transportation from site of work to workshop for repairing and back at site complete all as directed by Engr-in-Charge
54M&L for Replacement of complete wiring of DG Set control panel 160 to 320 KVAcapacity including wiring of Gauge display panel mounted on engine , panel must be functional with manual start and stop bottomslubricant oil pressure meter, RPM meter ,temperature meter etc.Replacement of control wiring is included in the job and complete testing of DG Set by making all control parameters of DG Set functional. Note :- All new spare partsshall be measured and paid for separately as supply only under respective items of BOQ
55Supply & fixing onlyin replacement of the following items for DG Set 160KVA to 320 KVA capacity :-
56AVR Controller 180 KVA
57AVR Controller 320 KVA
58AVR Controller 250 KVA
59Ammeter for Battery charging
60Startand Stop push Button
61AMF Controller up to 180KVA
62AMF Controller 200&250KVA
63AMF Controller320KVA
64M&L for replacement of existing unserviceable batteries of 160 AH, 12 volts, all as specified and directed. Make: EXIDE /Amron/AMCO/Okaya/ Sukam/Microtek
65M&L for replacementof existing unserviceable batteries of 180 AH, 12 volts, all as specified and directed. Make: EXIDE /Amron/AMCO/Okaya/ Sukam/Microtek
66M&L for replacementof existing unserviceable batteries of 26 AH, 12 volts, for UPS all as specified and directed. Make: EXIDE /Amron/AMCO/Okaya/ Sukam/Microtek
67Draining out the old used engine oil / sump cleaning and refilling with new engine oil 15 W 40 CF4 Grade upto the required level complete all as specified.Make: Castrol/Valvo Line or equivalent as approved by GE.
68Supply & fixingin replacement of battery lead heavy dutysize not less than 25 sqmm of copper conductor standardred for (positive) terminal and black for (negative) terminal with battery terminal of one end and battery lugs at other end complete all as specified.
69Supply & fixing ofcoolant Antifreeze Green Concentratefor any type DG SET radatior assamblycomplete all as specified.
70Supply & fixingin replacement of battery terminal clamps made up of brass heavy duty with nuts and bolts complete all as specified.
71S&Fin replacement of asbestos rope 10 to 15 mm dia to be fixed on the Engine exhaust manifold andexexhaus pipe of sizesincludingremoving of existing unserviceable asbestos ropecomplete all as directed.
72Supply & fixing in replacement of complete gaskit set of DG SET complete all as specified and as directed by Engineer-in-Charge.
73Supply & fixing in replacement ofsuitable size of nut bolts/ washers complete all as specified and as directed . Make : TVS or equivalent as approved by GE.
74Earthing complete with copper earth plate electrode of size 60cmx60cmx3.15mm thickas earth electrodeburried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth strip 20x3mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including joining of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board/ panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil, removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-Charge including testing on completion. Note :- (a)1.5 cubic metre of soil shall be provided by the contractor from outside the MOD land for refilling the remaining portion of earth pit for increasing soil resistance without any extra cost of the Govt. (b)Earthing will be carried out in presence of users rep with their entire satisfaction. (c)Payment will be made after obtaining user signature.
75Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required 2mm dia but 20x3mm copper strip
76Supply, laying , jointing , commissioning and testing cable(armoured) XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size185 sqmm ,3.5 core laid on walls/floors or in air with saddles and gutties,complete all as specified and directed by Engr-in-Charge
77S&F insulating MATof size 2m x lm x 10 mm complete all as specified & directed
78Supply and fill earth enhancement compound tested from NABL accredited laboratory, highly conductive non-corrosive in nature having low water solubility but highly hygroscopic, fully cimlaint to specifications given in IEC 62561-7-2018 all as directed Make : Truepower/ OBO Batternan/ nVent-ERICO
79Supply and filling charcoal dust in alternate layers in earth pit all as specified and as directed
80Supply and filling common salt in laternate layers in earth pit all as specified and as directed
81Supply and filling magnesium sulphate in earth pit all as specified and as directed
82Disconnecting off 200 KVA to 320 KVA DG Set parts & electric connection and taking down the following item & kept at site for re-use or removal to storeand tranporting of civ work shop Udhampurcomplete all as directed by Engr-in-Charge. (a)M & L for pistan set 1 set 6 Nos Complete all as specified and as directed by Engineer-in-Charge. (b)M & L forLinerset 1 set 6 Nos Complete Complete all as specified and as directed by Engineer-in-Charge. (c)M & L for Liner o Ringset 1 set 6 NosComplete all as specified and as directed by Engineer-in-Charge. (d)M & L for Ringset 1 set 18 NosComplete all as specified and as directed by Engineer-in-Charge. (e)M & L for Head Gasket6 NosComplete all as specified and as directed by Engineer-in-Charge. (f)M & L for Vave set Inlet of Exhaust12 Nos Complete (g)M & L for Head valve seal 12 Nos Complete all as specified and as directed by Engineer-in-Charge. (h)M & L for Head valve set 12 NosComplete all as specified and as directed by Engineer-in-Charge. (i) M & L for L/Lop Sensor1 setComplete all as specified and as directed by Engineer-in-Charge. (j)M & L for Headoil filter 2 Nos Complete all as specified and as directed by Engineer-in-Charge. (k)M & L for fan belt set3 Nos Complete all as specified and as directed by Engineer-in-Charge. (l)M & L for paking kit1NosComplete all as specified and as directed by Engineer-in-Charge. (m)M & L forAIR Cleaner element 1 NosComplete all as specified and as directed by Engineer-in-Charge. (n)M & L for Hose pipe set 1 NosComplete all as specified and as directed by Engineer-in-Charge. (o)M & L for Hose pipe set 4NosComplete all as specified and as directed by Engineer-in-Charge. (p)M & L for hose clamp4 setComplete all as specified and as directed by Engineer-in-Charge. (q)M & L forwasher 1 set Complete all as specified and as directed by Engineer-in-Charge. (r)M & L for fuel pipe line 2 pic Complete all as specified and as directed by Engineer-in-Charge. (s)M & L for Radiator After coll and checking and repair Complete all as specified and as directed by Engineer-in-Charge. (t)M & L foridael gear bush set1 set Complete all as specified and as directed by Engineer-in-Charge. (u)M & L forHain oil seal set1 setComplete all as specified and as directed by Engineer-in-Charge. (v)M & L for timing cover oil seal 1 setComplete all as specified and as directed by Engineer-in-Charge. (w) M & L forCraine Granding1 setComplete all as specified and as directed by Engineer-in-Charge. (x)M & L forFIP Complete over hauling1 set Complete Complete all as specified and as directed by Engineer-in-Charge. (y)M & L for turbo charger Repair 1 set Complete Complete all as specified and as directed by Engineer-in-Charge. (z)M & L for Temp Sensor1 set Complete all as specified and as directed by Engineer-in-Charge.
83Suply and fixing of Off load change over 630 Amps with copper busbar complete all as specifeid and as directed
84Note : Total amount of Schedule of Credit for retrieved material mentioned on General summary of Tender documents in PDF formatwill be deducted offline during acceptance of Tender
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail