Rate Contract Of Cardiology Items , Rate Contract Of Cardio Items , Radial Sheathwith Puncture Needle For Adults ( Sizes 4 - 11 Fr. ) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-Way Stopcock Snap-On / Click-Off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20G*2 Entry Needle ( Plastic Iv Catheter ) • Usfda / Pmda Approved , Radial Sheathwith Puncture Needle For Adults ( Sizes 4 - 11 Fr. ) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-Way Stopcock Snap-On / Click-Off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20G*2 Entry Needle ( Plastic Iv Catheter ) • Ce - Approved , Radial Sheathwith Puncture Needle For Adults ( Sizes 4 - 11 Fr. ) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-Way Stopcock Snap-On / Click-Off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20G*2 Entry Needle ( Plastic Iv Catheter ) • Dcgi Approved , Radial Sheath:- 4 To 7 Fr • 0.21” Gw Compatible • Length 11 Cm • 21 G Needle • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Maneuverability With Minimal Leakage • Cannula Made Of Two Thinner Layers Of Polyethylene • Color Codes For Easy French Size Identification • Usfda / Pmda Approved , Radial Sheath:- 4 To 7 Fr • 0.21” Gw Compatible • Length 11 Cm • 21 G Needle • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Maneuverability With Minimal Leakage • Cannula Made Of Two Thinner Layers Of Polyethylene • Color Codes For Easy French Size Identification • Ce- Approved , Radial Sheath:- 4 To 7 Fr • 0.21” Gw Compatible • Length 11 Cm • 21 G Needle • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Maneuverability With Minimal Leakage • Cannula Made Of Two Thinner Layers Of Polyethylene • Color Codes For Easy French Size Identification • Dcgi- Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size • Usfda / Pmda Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size • Ce -Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size • Dcgi -Approved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 1.5 T Mri Compatible ( Full Body ) • Usfda / Pmda Approved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 1.5 T Mri Compatible ( Full Body ) • Ce- Approved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 1.5 T Mri Compatible ( Full Body ) • Dcgi -Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Usfda / Pmda Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Ce-Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Dcgi-Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Usfda / Pmda Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Ce- Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Dcgi - Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Usfda / Pmda Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Ce - Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Dcgi - Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Usfda / Pmda Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Ce - Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Dcgi - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Single Chamber Pacemaker • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Single Chamber Pacemaker • Lead Profile Up To 6 Fr. • Ce - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Single Chamber Pacemaker • Lead Profile Up To 6 Fr. • Dcgi - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Double Chamber Pacemaker • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Double Chamber Pacemaker • Lead Profile Up To 6 Fr. • Ce - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Double Chamber Pacemaker • Lead Profile Up To 6 Fr. • Dcgi - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-P • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-P • Lead Profile Up To 6 Fr. • Ce - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-P • Lead Profile Up To 6 Fr. • Dcgi- Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-D • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-D • Lead Profile Up To 6 Fr. • Ce Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-D • Lead Profile Up To 6 Fr. • Dcgiapproved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Usfda / Pmda - Approved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Ce - Approved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Dcgi - Approved , Pacemaker ( Pg ) Without Lead And Peel Away Sheathfor The Existing Company Providing Complete Pacemaker At Rnt Medical College • Usfda / Pmda Approved , Pacemaker ( Pg ) Without Lead And Peel Away Sheathfor The Existing Company Providing Complete Pacemaker At Rnt Medical College • Ce - Approved , Pacemaker ( Pg ) Without Lead And Peel Away Sheathfor The Existing Company Providing Complete Pacemaker At Rnt Medical College • Dcgi - Approved , Ptca Balloon ( Semi Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Usfda / Pmda Approved , Ptca Balloon ( Semi Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Ce-Approved , Ptca Balloon ( Semi Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Dcgi-Approved , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Usfda / Pmda Approved , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Ce-Approved , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Dcgi-Approved , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Usfda / Pmda Approved , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Ce - Approved , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Dcgi - Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Usfda / Pmda Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Ce – Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Dcgi - Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Usfda / Pmda Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Ce - Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Dcgi - Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Usfda / Pmda Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Ce - Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Dcgi - Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Usfda / Pmda Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Ce - Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Dcgi - Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Usfda / Pmda Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Ce - Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Dcgi - Approved , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Usfda / Pmda Approve , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Ce Approved , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Dcgi Approved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Usfda / Pmdaapproved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Ce Approved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Dcgi Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Usfda / Pmda Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Ce Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Dcgi Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Usfda / Pmda Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Ce Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Dcgi Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Usfda / Pmda Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Ce Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Dcgi Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Usfda / Pmda Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Ce Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Dcgi Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6 To30 • Diameter ( Mm ) : 2 To5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Usfda / Pmda Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6 To 30 • Diameter ( Mm ) : 2 To 5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Ce Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6To 30 • Diameter ( Mm ) : 2 To 5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Dcgi Approved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Dcgi Approved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Dcgi Approved , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved. , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Dcgiapproved. , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Usfda / Pmdaapproved , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Ce - Approved , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Dcgi - Approved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Usfda / Pmdaapproved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Ce- Approved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Dcgi- Approved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimum Visualization • With Tfe Coating , 180 Cm To 300Cm • Usfda / Pmdaapproved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimum Visualization • With Tfe Coating , 180 Cm To 300Cm • Ce - Approved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimum Visualization • With Tfe Coating , 180 Cm To 300Cm • Dcgi - Approved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long •Usfda / Pmdaapproved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long •Ce – Approved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long • Dcgi – Approved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Usfda / Pmdaapproved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Ce – Approved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Dcgi- Approved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Usfda / Pmdaapproved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Ce - Approved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Dcgi - Approved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Usfda / Pmdaapproved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Ce - Approved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Ce - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Dcgi - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Ce - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Dcgi- Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Dcgi – Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Dcgi- Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Dcgi - Approved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Usfda / Pmdaapproved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Ce - Approved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Dcgi – Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Dcgi- Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Dcgi - Approved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Usfda / Pmdaapproved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Ce - Approved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Dcgi - Approved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Usfda / Pmdaapproved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Ce - Approved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Dcgi - Approved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Usfda / Pmdaapproved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Ce- Approved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Dcgi - Approved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Usfda / Pmdaapproved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Ce - Approved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Dcgi - Approved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Usfda / Pmdaapproved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Ce - Approved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Dcgi - Approved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Usfda / Pmdaapproved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Ce - Approved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Dcgi - Approved , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Usfda / Pmdaapproved Wire Lengths-190 Cm & 300 Cm , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Ce-Approved Wire Lengths-190 Cm & 300 Cm , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Dcgi- Approved Wire Lengths-190 Cm & 300 Cm , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Usfda / Pmdaapproved , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Ce- Approved , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Dcgi - Approved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Usfda / Pmdaapproved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Ce- Approved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Dcgi - Approved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Usfda / Pmdaapproved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Ce - Approved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Dcgi - Approved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Usfda / Pmdaapproved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Ce- Approved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Dcgi - Approved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Usfda / Pmdaapproved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Ce - Approved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Dcgi - Approved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Usfda / Pmdaapproved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Ce - Approved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Dcgi - Approved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size Usfda / Pmdaapproved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size • Ce- Approved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size • Dcgi- Approved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Usfda / Pmdaapproved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Ce - Approved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Dcgi - Approved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Usfda / Pmdaapproved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Ce - Approved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Dcgi - Approved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Usfda / Pmdaapproved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Ce - Approved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Dcgi - Approved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Usfda / Pmdaapproved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Ce - Approved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Dcgi - Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Usfda / Pmdaapproved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Ce Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Dcgi- Approved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Usfda / Pmdaapproved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Ce- Approved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Dcgi- Approved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Usfda / Pmdaapproved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Ce - Approved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Dcgi - Approved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Usfda / Pmdaapproved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Ce - Approved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Dcgi - Approved , Asd Closure Devices Without Delivery System • Usfda / Pmdaapproved , Asd Closure Devices Without Delivery System • Ce - Approved , Asd Closure Devices Without Delivery System • Dcgi - Approved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Usfda / Pmdaapproved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Ce- Approved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Dcgi - Approved , Asd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Usfda / Pmdaapproved , Asd Closure Device With Delivery System :-Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Ce - Approved , Asd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Dcgi - Approved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Usfda / Pmdaapproved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Ce - Approved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Dcgi - Approved , Left Atrial Appendage Closure Device • Usfda / Pmdaapproved , Left Atrial Appendage Closure Device • Ce - Approved , Left Atrial Appendage Closure Device • Dcgi- Approved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Usfda / Pmdaapproved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Ce - Approved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Dcgi - Approved , Pfo Closure Devices Without Delivery System – • Usfda / Pmdaapproved , Pfo Closure Devices Without Delivery System – • Ce- Approved , Pfo Closure Devices Without Delivery System – • D Cgi- Approved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Usfda / Pmdaapproved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Ce - Approved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Dcgi - Approved , Sizing Balloon For Device Closure – Circular Shape • Usfda / Pmdaapproved , Sizing Balloon For Device Closure – Circular Shape • Ce - Approved , Sizing Balloon For Device Closure – Circular Shape • Dcgi- Approved , Sizing Balloon For Device Closure – Oval Shaped • Usfda / Pmdaapproved , Sizing Balloon For Device Closure – Oval Shaped • Ce- Approved , Sizing Balloon For Device Closure – Oval Shaped • Dcgi - Approved , Sizing Plate For Device Closure – • Usfda / Pmdaapproved , Sizing Plate For Device Closure – • Ce -Approved , Sizing Plate For Device Closure – • Dcgi-Approved , Delivery Cable For Asd / Vsd / Pda Devices – • Usfda / Pmdaapproved , Delivery Cable For Asd / Vsd / Pda Devices – • Ce- Approved , Delivery Cable For Asd / Vsd / Pda Devices – • Dcgi- Approved , Retrievers For Asd / Vsd / Pda Devices – • Usfda / Pmdaapproved , Retrievers For Asd / Vsd / Pda Devices – • Ce- Approved , Retrievers For Asd / Vsd / Pda Devices – • Dcgi- Approved , Sheath For Retrival Of Devices – • Usfda / Pmdaapproved , Sheath For Retrival Of Devices – • Ce- Approved , Sheath For Retrival Of Devices – • Dcgi- Approved , Amplatzer Plug- • Usfda / Pmdaapproved , Amplatzer Plug- • Ce- Approved , Amplatzer Plug- • Dcgi- Approved , Left Atrial Apendage Closure Device- • Usfda / Pmdaapproved , Left Atrial Apendage Closure Device- • Ce- Approved , Left Atrial Apendage Closure Device- • Dcgi- Approved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Usfda / Pmdaapproved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Ce-Approved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Dcgi-Approved , Vsd Closure Devices Without Delivery System – • Usfda / Pmdaapproved , Vsd Closure Devices Without Delivery System – • Ce-Approved , Vsd Closure Devices Without Delivery System – • Dcgi-Approved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Usfda / Pmdaapproved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Ce-Approved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Dcgi-Approved , Vsd Closure Device With Delivery System :- Elongatable Waist Soft Woven Mesh Low Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Usfda / Pmdaapproved , Vsd Closure Device With Delivery System :-Elongatable Waist Soft Woven Mesh Low Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Ce-Approved , Vsd Closure Device With Delivery System :- Elongatable Waist Soft Woven Meshlow Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Dcgi-Approved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Usfda / Pmdaapproved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Ce-Approved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Dcgi-Approved , Pda Closure Devices Without Delivery System • Usfda / Pmdaapproved , Pda Closure Devices Without Delivery System • Ce-Approved , Pda Closure Devices Without Delivery System • Dcgi-Approved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Usfda / Pmdaapproved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Ce-Approved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Dcgi-Approved , Pda Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Usfda / Pmdaapproved , Pda Closure Device With Delivery System :-Oated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Ce-Approved , Pda Closure Device With Delivery System :-Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Dcgi-Approved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Usfda / Pmdaapproved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Ce-Approved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Dcgi-Approved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Usfda / Pmdaapproved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Ce-Approved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Dcgi-Approved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Usfda / Pmdaapproved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Ceapproved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Dcgiapproved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Usfda / Pmdaapproved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Ce-Approved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Dcgi-Approved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Usfda / Pmdaapproved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Ce-Approved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Dcgi-Approved , Pediatricfemoral Sheath 4 Fr. • Usfda / Pmdaapproved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Usfda / Pmdaapproved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Ce-Approved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Dcgi-Approved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Usfda / Pmdaapproved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Ce-Approved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Dcgi-Approved , Mullin Sheath With Dilator • Usfda / Pmdaapproved , Mullin Sheath With Dilator • Ce-Approved , Mullin Sheath With Dilator • Dcgi-Approved , Trans- Septal Needle. • Usfda / Pmdaapproved , Trans- Septal Needle. • Ce-Approved , Trans- Septal Needle. • Dcgi-Approved , Brs Stent • Scaffold Matarial- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Usfda / Pmdaapproved , Brs Stent • Scaffold Matarial- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Ce-Approved , Brs Stent • Scaffold Matarial- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Dcgi-Approved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Usfda / Pmdaapproved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Ce Approved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Dcgi Approved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Usfda / Pmdaapproved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Ce Approved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Dcgi Approved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Usfda / Pmdaapproved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Ce Approved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Dcgi Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Usfda Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Ce Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Dcgi Approved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Usfda / Pmdaapproved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Ce Approved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Dcgi Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Usfda / Pmda Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Ce Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Dcgi Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Usfda / Pmda Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Ce Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Dcgi Approved , Guide Extension Catheter- • Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Usfda / Pmda Approved , Guide Extension Catheter- •Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Ce Approved , Guide Extension Catheter- •Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Dcgi Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Usfda / Pmda Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Ce Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Dcgi Approved , Special Ptca Balloon For Cto Lesions • Starting Diameter0.85 Mm • Rbp 16 Atm Or Above. • Low Entry Tip Profile Equal To Or Less Than 0.015”. Balloon Hypotube Must Be-Spiral-Cut Design. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons • Usfda / Pmda Approved , Special Ptca Balloon For Cto Lesions • Starting Diameter0.85 Mm • Rbp 16 Atm Or Above. • Low Entry Tip Profile Equal To Or Less Than 0.015”. Balloon Hypotube Must Be-Spiral-Cut Design. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons • Ce Approved , Special Ptca Balloon For Cto Lesions • Starting Diameter0.85 Mm • Rbp 16 Atm Or Above. • Low Entry Tip Profile Equal To Or Less Than 0.015”. Balloon Hypotube Must Be-Spiral-Cut Design. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons • Dcgi Approved , Special Ptca Balloon ( Non-Compliant ) . • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Usfda / Pmda Approved , Special Ptca Balloon ( Non-Compliant ) . • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Ce Approved , Special Ptca Balloon ( Non-Compliant ) . • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Dcgi Approved