Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #34906678

Tender For Rate Contract Of Cardiology Items

Issued by Boards / Undertakings / PSU · Udaipur, Rajasthan
Tender Value
10 Crore
Estimated cost
Bid Submission
27 Dec 2022
0 days left
EMD
20 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Rate Contract Of Cardiology Items , Rate Contract Of Cardio Items , Radial Sheathwith Puncture Needle For Adults ( Sizes 4 - 11 Fr. ) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-Way Stopcock Snap-On / Click-Off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20G*2 Entry Needle ( Plastic Iv Catheter ) • Usfda / Pmda Approved , Radial Sheathwith Puncture Needle For Adults ( Sizes 4 - 11 Fr. ) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-Way Stopcock Snap-On / Click-Off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20G*2 Entry Needle ( Plastic Iv Catheter ) • Ce - Approved , Radial Sheathwith Puncture Needle For Adults ( Sizes 4 - 11 Fr. ) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-Way Stopcock Snap-On / Click-Off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20G*2 Entry Needle ( Plastic Iv Catheter ) • Dcgi Approved , Radial Sheath:- 4 To 7 Fr • 0.21” Gw Compatible • Length 11 Cm • 21 G Needle • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Maneuverability With Minimal Leakage • Cannula Made Of Two Thinner Layers Of Polyethylene • Color Codes For Easy French Size Identification • Usfda / Pmda Approved , Radial Sheath:- 4 To 7 Fr • 0.21” Gw Compatible • Length 11 Cm • 21 G Needle • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Maneuverability With Minimal Leakage • Cannula Made Of Two Thinner Layers Of Polyethylene • Color Codes For Easy French Size Identification • Ce- Approved , Radial Sheath:- 4 To 7 Fr • 0.21” Gw Compatible • Length 11 Cm • 21 G Needle • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Maneuverability With Minimal Leakage • Cannula Made Of Two Thinner Layers Of Polyethylene • Color Codes For Easy French Size Identification • Dcgi- Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size • Usfda / Pmda Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size • Ce -Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size • Dcgi -Approved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 1.5 T Mri Compatible ( Full Body ) • Usfda / Pmda Approved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 1.5 T Mri Compatible ( Full Body ) • Ce- Approved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 1.5 T Mri Compatible ( Full Body ) • Dcgi -Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Usfda / Pmda Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Ce-Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Dcgi-Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Usfda / Pmda Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Ce- Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Dcgi - Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Usfda / Pmda Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Ce - Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Dcgi - Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Usfda / Pmda Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Ce - Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Dcgi - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Single Chamber Pacemaker • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Single Chamber Pacemaker • Lead Profile Up To 6 Fr. • Ce - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Single Chamber Pacemaker • Lead Profile Up To 6 Fr. • Dcgi - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Double Chamber Pacemaker • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Double Chamber Pacemaker • Lead Profile Up To 6 Fr. • Ce - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Double Chamber Pacemaker • Lead Profile Up To 6 Fr. • Dcgi - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-P • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-P • Lead Profile Up To 6 Fr. • Ce - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-P • Lead Profile Up To 6 Fr. • Dcgi- Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-D • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-D • Lead Profile Up To 6 Fr. • Ce Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-D • Lead Profile Up To 6 Fr. • Dcgiapproved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Usfda / Pmda - Approved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Ce - Approved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Dcgi - Approved , Pacemaker ( Pg ) Without Lead And Peel Away Sheathfor The Existing Company Providing Complete Pacemaker At Rnt Medical College • Usfda / Pmda Approved , Pacemaker ( Pg ) Without Lead And Peel Away Sheathfor The Existing Company Providing Complete Pacemaker At Rnt Medical College • Ce - Approved , Pacemaker ( Pg ) Without Lead And Peel Away Sheathfor The Existing Company Providing Complete Pacemaker At Rnt Medical College • Dcgi - Approved , Ptca Balloon ( Semi Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Usfda / Pmda Approved , Ptca Balloon ( Semi Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Ce-Approved , Ptca Balloon ( Semi Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Dcgi-Approved , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Usfda / Pmda Approved , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Ce-Approved , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Dcgi-Approved , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Usfda / Pmda Approved , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Ce - Approved , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Dcgi - Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Usfda / Pmda Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Ce – Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Dcgi - Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Usfda / Pmda Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Ce - Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Dcgi - Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Usfda / Pmda Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Ce - Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Dcgi - Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Usfda / Pmda Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Ce - Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Dcgi - Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Usfda / Pmda Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Ce - Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Dcgi - Approved , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Usfda / Pmda Approve , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Ce Approved , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Dcgi Approved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Usfda / Pmdaapproved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Ce Approved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Dcgi Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Usfda / Pmda Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Ce Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Dcgi Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Usfda / Pmda Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Ce Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Dcgi Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Usfda / Pmda Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Ce Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Dcgi Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Usfda / Pmda Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Ce Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Dcgi Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6 To30 • Diameter ( Mm ) : 2 To5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Usfda / Pmda Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6 To 30 • Diameter ( Mm ) : 2 To 5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Ce Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6To 30 • Diameter ( Mm ) : 2 To 5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Dcgi Approved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Dcgi Approved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Dcgi Approved , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved. , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Dcgiapproved. , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Usfda / Pmdaapproved , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Ce - Approved , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Dcgi - Approved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Usfda / Pmdaapproved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Ce- Approved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Dcgi- Approved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimum Visualization • With Tfe Coating , 180 Cm To 300Cm • Usfda / Pmdaapproved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimum Visualization • With Tfe Coating , 180 Cm To 300Cm • Ce - Approved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimum Visualization • With Tfe Coating , 180 Cm To 300Cm • Dcgi - Approved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long •Usfda / Pmdaapproved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long •Ce – Approved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long • Dcgi – Approved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Usfda / Pmdaapproved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Ce – Approved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Dcgi- Approved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Usfda / Pmdaapproved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Ce - Approved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Dcgi - Approved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Usfda / Pmdaapproved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Ce - Approved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Ce - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Dcgi - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Ce - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Dcgi- Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Dcgi – Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Dcgi- Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Dcgi - Approved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Usfda / Pmdaapproved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Ce - Approved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Dcgi – Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Dcgi- Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Dcgi - Approved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Usfda / Pmdaapproved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Ce - Approved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Dcgi - Approved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Usfda / Pmdaapproved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Ce - Approved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Dcgi - Approved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Usfda / Pmdaapproved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Ce- Approved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Dcgi - Approved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Usfda / Pmdaapproved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Ce - Approved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Dcgi - Approved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Usfda / Pmdaapproved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Ce - Approved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Dcgi - Approved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Usfda / Pmdaapproved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Ce - Approved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Dcgi - Approved , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Usfda / Pmdaapproved Wire Lengths-190 Cm & 300 Cm , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Ce-Approved Wire Lengths-190 Cm & 300 Cm , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Dcgi- Approved Wire Lengths-190 Cm & 300 Cm , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Usfda / Pmdaapproved , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Ce- Approved , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Dcgi - Approved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Usfda / Pmdaapproved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Ce- Approved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Dcgi - Approved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Usfda / Pmdaapproved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Ce - Approved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Dcgi - Approved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Usfda / Pmdaapproved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Ce- Approved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Dcgi - Approved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Usfda / Pmdaapproved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Ce - Approved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Dcgi - Approved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Usfda / Pmdaapproved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Ce - Approved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Dcgi - Approved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size Usfda / Pmdaapproved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size • Ce- Approved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size • Dcgi- Approved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Usfda / Pmdaapproved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Ce - Approved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Dcgi - Approved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Usfda / Pmdaapproved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Ce - Approved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Dcgi - Approved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Usfda / Pmdaapproved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Ce - Approved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Dcgi - Approved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Usfda / Pmdaapproved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Ce - Approved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Dcgi - Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Usfda / Pmdaapproved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Ce Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Dcgi- Approved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Usfda / Pmdaapproved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Ce- Approved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Dcgi- Approved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Usfda / Pmdaapproved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Ce - Approved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Dcgi - Approved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Usfda / Pmdaapproved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Ce - Approved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Dcgi - Approved , Asd Closure Devices Without Delivery System • Usfda / Pmdaapproved , Asd Closure Devices Without Delivery System • Ce - Approved , Asd Closure Devices Without Delivery System • Dcgi - Approved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Usfda / Pmdaapproved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Ce- Approved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Dcgi - Approved , Asd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Usfda / Pmdaapproved , Asd Closure Device With Delivery System :-Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Ce - Approved , Asd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Dcgi - Approved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Usfda / Pmdaapproved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Ce - Approved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Dcgi - Approved , Left Atrial Appendage Closure Device • Usfda / Pmdaapproved , Left Atrial Appendage Closure Device • Ce - Approved , Left Atrial Appendage Closure Device • Dcgi- Approved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Usfda / Pmdaapproved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Ce - Approved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Dcgi - Approved , Pfo Closure Devices Without Delivery System – • Usfda / Pmdaapproved , Pfo Closure Devices Without Delivery System – • Ce- Approved , Pfo Closure Devices Without Delivery System – • D Cgi- Approved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Usfda / Pmdaapproved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Ce - Approved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Dcgi - Approved , Sizing Balloon For Device Closure – Circular Shape • Usfda / Pmdaapproved , Sizing Balloon For Device Closure – Circular Shape • Ce - Approved , Sizing Balloon For Device Closure – Circular Shape • Dcgi- Approved , Sizing Balloon For Device Closure – Oval Shaped • Usfda / Pmdaapproved , Sizing Balloon For Device Closure – Oval Shaped • Ce- Approved , Sizing Balloon For Device Closure – Oval Shaped • Dcgi - Approved , Sizing Plate For Device Closure – • Usfda / Pmdaapproved , Sizing Plate For Device Closure – • Ce -Approved , Sizing Plate For Device Closure – • Dcgi-Approved , Delivery Cable For Asd / Vsd / Pda Devices – • Usfda / Pmdaapproved , Delivery Cable For Asd / Vsd / Pda Devices – • Ce- Approved , Delivery Cable For Asd / Vsd / Pda Devices – • Dcgi- Approved , Retrievers For Asd / Vsd / Pda Devices – • Usfda / Pmdaapproved , Retrievers For Asd / Vsd / Pda Devices – • Ce- Approved , Retrievers For Asd / Vsd / Pda Devices – • Dcgi- Approved , Sheath For Retrival Of Devices – • Usfda / Pmdaapproved , Sheath For Retrival Of Devices – • Ce- Approved , Sheath For Retrival Of Devices – • Dcgi- Approved , Amplatzer Plug- • Usfda / Pmdaapproved , Amplatzer Plug- • Ce- Approved , Amplatzer Plug- • Dcgi- Approved , Left Atrial Apendage Closure Device- • Usfda / Pmdaapproved , Left Atrial Apendage Closure Device- • Ce- Approved , Left Atrial Apendage Closure Device- • Dcgi- Approved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Usfda / Pmdaapproved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Ce-Approved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Dcgi-Approved , Vsd Closure Devices Without Delivery System – • Usfda / Pmdaapproved , Vsd Closure Devices Without Delivery System – • Ce-Approved , Vsd Closure Devices Without Delivery System – • Dcgi-Approved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Usfda / Pmdaapproved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Ce-Approved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Dcgi-Approved , Vsd Closure Device With Delivery System :- Elongatable Waist Soft Woven Mesh Low Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Usfda / Pmdaapproved , Vsd Closure Device With Delivery System :-Elongatable Waist Soft Woven Mesh Low Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Ce-Approved , Vsd Closure Device With Delivery System :- Elongatable Waist Soft Woven Meshlow Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Dcgi-Approved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Usfda / Pmdaapproved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Ce-Approved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Dcgi-Approved , Pda Closure Devices Without Delivery System • Usfda / Pmdaapproved , Pda Closure Devices Without Delivery System • Ce-Approved , Pda Closure Devices Without Delivery System • Dcgi-Approved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Usfda / Pmdaapproved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Ce-Approved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Dcgi-Approved , Pda Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Usfda / Pmdaapproved , Pda Closure Device With Delivery System :-Oated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Ce-Approved , Pda Closure Device With Delivery System :-Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Dcgi-Approved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Usfda / Pmdaapproved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Ce-Approved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Dcgi-Approved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Usfda / Pmdaapproved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Ce-Approved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Dcgi-Approved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Usfda / Pmdaapproved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Ceapproved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Dcgiapproved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Usfda / Pmdaapproved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Ce-Approved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Dcgi-Approved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Usfda / Pmdaapproved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Ce-Approved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Dcgi-Approved , Pediatricfemoral Sheath 4 Fr. • Usfda / Pmdaapproved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Usfda / Pmdaapproved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Ce-Approved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Dcgi-Approved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Usfda / Pmdaapproved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Ce-Approved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Dcgi-Approved , Mullin Sheath With Dilator • Usfda / Pmdaapproved , Mullin Sheath With Dilator • Ce-Approved , Mullin Sheath With Dilator • Dcgi-Approved , Trans- Septal Needle. • Usfda / Pmdaapproved , Trans- Septal Needle. • Ce-Approved , Trans- Septal Needle. • Dcgi-Approved , Brs Stent • Scaffold Matarial- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Usfda / Pmdaapproved , Brs Stent • Scaffold Matarial- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Ce-Approved , Brs Stent • Scaffold Matarial- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Dcgi-Approved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Usfda / Pmdaapproved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Ce Approved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Dcgi Approved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Usfda / Pmdaapproved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Ce Approved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Dcgi Approved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Usfda / Pmdaapproved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Ce Approved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Dcgi Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Usfda Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Ce Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Dcgi Approved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Usfda / Pmdaapproved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Ce Approved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Dcgi Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Usfda / Pmda Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Ce Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Dcgi Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Usfda / Pmda Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Ce Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Dcgi Approved , Guide Extension Catheter- • Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Usfda / Pmda Approved , Guide Extension Catheter- •Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Ce Approved , Guide Extension Catheter- •Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Dcgi Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Usfda / Pmda Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Ce Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Dcgi Approved , Special Ptca Balloon For Cto Lesions • Starting Diameter0.85 Mm • Rbp 16 Atm Or Above. • Low Entry Tip Profile Equal To Or Less Than 0.015”. Balloon Hypotube Must Be-Spiral-Cut Design. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons • Usfda / Pmda Approved , Special Ptca Balloon For Cto Lesions • Starting Diameter0.85 Mm • Rbp 16 Atm Or Above. • Low Entry Tip Profile Equal To Or Less Than 0.015”. Balloon Hypotube Must Be-Spiral-Cut Design. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons • Ce Approved , Special Ptca Balloon For Cto Lesions • Starting Diameter0.85 Mm • Rbp 16 Atm Or Above. • Low Entry Tip Profile Equal To Or Less Than 0.015”. Balloon Hypotube Must Be-Spiral-Cut Design. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons • Dcgi Approved , Special Ptca Balloon ( Non-Compliant ) . • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Usfda / Pmda Approved , Special Ptca Balloon ( Non-Compliant ) . • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Ce Approved , Special Ptca Balloon ( Non-Compliant ) . • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Dcgi Approved

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 05-Dec-2022 date corrigendum Date 20-Dec-2022
2 13-Dec-2022 date change schedule Date 23-Dec-2022
3 16-Dec-2022 Corrigendum Technical Bid 23-Dec-2022
4 16-Dec-2022 Corrigendum date Date 23-Dec-2022
5 16-Dec-2022 Corrigendum OF BOQ BOQ 23-Dec-2022
6 24-Dec-2022 extension of dates Date 27-Dec-2022

BOQ

Name of Work: RATE CONTRACT OF Cardiology items
Sl. No. Item Description
1RATE CONTRACT OF CARDIO ITEMS
2Radial Sheathwith PUNCTURE NEEDLE FOR ADULTS (Sizes 4 - 11 Fr.) – • Standard Length ; With haemostatic cross cut valve to prevent back leak of blood and aspiration of air; • With Integrated side arm with attached 3-way stopcock Snap-on/click-off dilator lock ; • With suture eye for securing sheath; • Kink resistant; • With dilator-hub lock mechanism to prevent its back-out during insertion; • Material of sheath tubing should be made of PTFE, Cross cut valve should be made up of silicon rubber & should have silicone coating. dilator tube should be made up of polypropylene and should have silicon coating; Pack MUST include surf lash 20G*2 entry needle (plastic IV catheter)• USFDA/PMDA approved
3Radial Sheathwith PUNCTURE NEEDLE FOR ADULTS (Sizes 4 - 11 Fr.) – • Standard Length ; With haemostatic cross cut valve to prevent back leak of blood and aspiration of air; • With Integrated side arm with attached 3-way stopcock Snap-on/click-off dilator lock ; • With suture eye for securing sheath; • Kink resistant; • With dilator-hub lock mechanism to prevent its back-out during insertion; • Material of sheath tubing should be made of PTFE, Cross cut valve should be made up of silicon rubber & should have silicone coating. dilator tube should be made up of polypropylene and should have silicon coating; Pack MUST include surf lash 20G*2 entry needle (plastic IV catheter)• CE - approved
4Radial Sheathwith PUNCTURE NEEDLE FOR ADULTS (Sizes 4 - 11 Fr.) – • Standard Length ; With haemostatic cross cut valve to prevent back leak of blood and aspiration of air; • With Integrated side arm with attached 3-way stopcock Snap-on/click-off dilator lock ; • With suture eye for securing sheath; • Kink resistant; • With dilator-hub lock mechanism to prevent its back-out during insertion; • Material of sheath tubing should be made of PTFE, Cross cut valve should be made up of silicon rubber & should have silicone coating. dilator tube should be made up of polypropylene and should have silicon coating; Pack MUST include surf lash 20G*2 entry needle (plastic IV catheter)• DCGI approved
5Radial Sheath:- 4 to 7 FR• 0.21” GW Compatible • Length 11 cm• 21 G needle• Removable cap which has hexacuspid valve• Excellent kink resistant• Sideport extension with 3-way stopcock• Optimized catheter maneuverability with minimal leakage• Cannula made of two thinner layers of polyethylene• Color codes for easy French size identification• USFDA/PMDA approved
6Radial Sheath:- 4 to 7 FR• 0.21” GW Compatible • Length 11 cm• 21 G needle• Removable cap which has hexacuspid valve• Excellent kink resistant• Sideport extension with 3-way stopcock• Optimized catheter maneuverability with minimal leakage• Cannula made of two thinner layers of polyethylene• Color codes for easy French size identification• CE- approved
7Radial Sheath:- 4 to 7 FR• 0.21” GW Compatible • Length 11 cm• 21 G needle• Removable cap which has hexacuspid valve• Excellent kink resistant• Sideport extension with 3-way stopcock• Optimized catheter maneuverability with minimal leakage• Cannula made of two thinner layers of polyethylene• Color codes for easy French size identification• DCGI- approved
8• Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Comes with Transradial catheter shapes designed to cannulate left and right coronary arteries eg: TIG, TIG II, JACKY, SARAH. Largest Inner diameter should be of maximum 10 F size• USFDA/PMDA approved
9• Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Comes with Transradial catheter shapes designed to cannulate left and right coronary arteries eg: TIG, TIG II, JACKY, SARAH. Largest Inner diameter should be of maximum 10 F size• CE -approved
10• Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Comes with Transradial catheter shapes designed to cannulate left and right coronary arteries eg: TIG, TIG II, JACKY, SARAH. Largest Inner diameter should be of maximum 10 F size• DCGI -approved
11Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in or tined lead •Standard warranty of minimum 10 yrs.• Auto capture mode •Minimize ventricular pacing mode • Beat to Beat capture mechanism• AF suppression • Optimization of AV delay •Pacemaker lead profile should be maximum up to 5 .8 Fr.• Lead should be compatible with 6 Fr.peel away sheath• 1.5 T MRI compatible (full body)• USFDA/PMDA approved
12Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in or tined lead •Standard warranty of minimum 10 yrs.• Auto capture mode •Minimize ventricular pacing mode • Beat to Beat capture mechanism• AF suppression • Optimization of AV delay •Pacemaker lead profile should be maximum up to 5 .8 Fr.• Lead should be compatible with 6 Fr.peel away sheath• 1.5 T MRI compatible (full body)• CE- approved
13Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in or tined lead •Standard warranty of minimum 10 yrs.• Auto capture mode •Minimize ventricular pacing mode • Beat to Beat capture mechanism• AF suppression • Optimization of AV delay •Pacemaker lead profile should be maximum up to 5 .8 Fr.• Lead should be compatible with 6 Fr.peel away sheath• 1.5 T MRI compatible (full body)• DCGI -approved
14Single Chamber ICD set• Should be supplied with 7.0to7.6 Fr. Defibrillator lead shouldbe compatible with 8 Fr. Peel away Sheath • Small size below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends with Alerts• 40J delivered energy with programmable Tilt and pulse width programming• Facility of Changing the shocking vector based on Over Current sensing• Special Sensing filter protection for T Wave overspending• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert• Facility of speciallycoated Device for avoiding lead abrasion• Proactive Measurement of ST Segment changes with Alerts• USFDA/PMDA approved
15Single Chamber ICD set• Should be supplied with 7.0to7.6 Fr. Defibrillator lead shouldbe compatible with 8 Fr. Peel away Sheath • Small size below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends with Alerts• 40J delivered energy with programmable Tilt and pulse width programming• Facility of Changing the shocking vector based on Over Current sensing• Special Sensing filter protection for T Wave overspending• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert• Facility of speciallycoated Device for avoiding lead abrasion• Proactive Measurement of ST Segment changes with Alerts• CE-approved
16Single Chamber ICD set• Should be supplied with 7.0to7.6 Fr. Defibrillator lead shouldbe compatible with 8 Fr. Peel away Sheath • Small size below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends with Alerts• 40J delivered energy with programmable Tilt and pulse width programming• Facility of Changing the shocking vector based on Over Current sensing• Special Sensing filter protection for T Wave overspending• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert• Facility of speciallycoated Device for avoiding lead abrasion• Proactive Measurement of ST Segment changes with Alerts• DCGI-approved
17Dual Chamber ICD set• Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead profile: should be maximum up to 5 .8 Fr. And lead should be compatible with 6 Fr.peel away sheath• Small size below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends with Alerts• Facility for overdriving Atrium for prevention of Atrial Arrythmias• 40J delivered energy with programmable Tilt and pulse width programming.• Facility of Changing the shocking vector based on Over Current sensing• Special Sensing filter protection for T Wave over sensing• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert• Proactive Measurement of ST Segment changes with Alerts• Facility of specially coated Device for avoiding lead abrasion (optional)• USFDA/PMDA approved
18Dual Chamber ICD set• Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead profile: should be maximum up to 5 .8 Fr. And lead should be compatible with 6 Fr.peel away sheath• Small size below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends with Alerts• Facility for overdriving Atrium for prevention of Atrial Arrythmias• 40J delivered energy with programmable Tilt and pulse width programming.• Facility of Changing the shocking vector based on Over Current sensing• Special Sensing filter protection for T Wave over sensing• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert• Proactive Measurement of ST Segment changes with Alerts• Facility of specially coated Device for avoiding lead abrasion (optional)• CE- approved
19Dual Chamber ICD set• Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead profile: should be maximum up to 5 .8 Fr. And lead should be compatible with 6 Fr.peel away sheath• Small size below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends with Alerts• Facility for overdriving Atrium for prevention of Atrial Arrythmias• 40J delivered energy with programmable Tilt and pulse width programming.• Facility of Changing the shocking vector based on Over Current sensing• Special Sensing filter protection for T Wave over sensing• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert• Proactive Measurement of ST Segment changes with Alerts• Facility of specially coated Device for avoiding lead abrasion (optional)• DCGI - approved
20Cardiac Resynchronization Pacemaker with all accessories - RA, RV and Bipolar LV leads and cathetersCRT-P• LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath• Atrial leadup to 5.8 Fr. and compatible with 6 Fr. Sheath• Heart Failure Congestion Monitoring Trends with Alerts• Facility for overdriving Atrium for prevention of Atrial Arrythmias• Electrocardiogram based AV Optimization for suggesting optimized AV Delays• warranty : Minimum 5 years on Device• Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead• Programmable AT/AF Alerts with AF Burden trending• Facility of specially coated Device for avoiding lead abrasion(optional)• Special Trigger Mode Biventricular Pacing in Presence of AT/AF• Facility of RF Telemetry• Should be supplied with 6 compatible leads and Introducers for RA & RV• LV lead delivery systems should be compatible with 7 Fr. EP catheters optional• USFDA /PMDA approved
21Cardiac Resynchronization Pacemaker with all accessories - RA, RV and Bipolar LV leads and cathetersCRT-P• LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath• Atrial leadup to 5.8 Fr. and compatible with 6 Fr. Sheath• Heart Failure Congestion Monitoring Trends with Alerts• Facility for overdriving Atrium for prevention of Atrial Arrythmias• Electrocardiogram based AV Optimization for suggesting optimized AV Delays• warranty : Minimum 5 years on Device• Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead• Programmable AT/AF Alerts with AF Burden trending• Facility of specially coated Device for avoiding lead abrasion(optional)• Special Trigger Mode Biventricular Pacing in Presence of AT/AF• Facility of RF Telemetry• Should be supplied with 6 compatible leads and Introducers for RA & RV• LV lead delivery systems should be compatible with 7 Fr. EP catheters optional• CE - approved
22Cardiac Resynchronization Pacemaker with all accessories - RA, RV and Bipolar LV leads and cathetersCRT-P• LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath• Atrial leadup to 5.8 Fr. and compatible with 6 Fr. Sheath• Heart Failure Congestion Monitoring Trends with Alerts• Facility for overdriving Atrium for prevention of Atrial Arrythmias• Electrocardiogram based AV Optimization for suggesting optimized AV Delays• warranty : Minimum 5 years on Device• Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead• Programmable AT/AF Alerts with AF Burden trending• Facility of specially coated Device for avoiding lead abrasion(optional)• Special Trigger Mode Biventricular Pacing in Presence of AT/AF• Facility of RF Telemetry• Should be supplied with 6 compatible leads and Introducers for RA & RV• LV lead delivery systems should be compatible with 7 Fr. EP catheters optional• DCGI - approved
23Cardiac Resynchronization defibrillator with with all accessories - RA, RV and Bipolar LV leads and catheters CRT-D• LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial leadup to 5.8 Fr. and compatible with 6 Fr. Sheath• 40J delivered energy• Pulse width and Tilt : Programmable as per DFT• Heart Failure Congestion Monitoring Trends with Alerts• Small size below 35cc• Warranty : Minimum 5 years• Facility of Changing the shocking vector based on Over Current sensing• Special Sensing filter protection for T Wave over sensing (optional)• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional• Facility of specially coated Device for avoiding lead abrasion (optional)• USFDA /PMDA approved
24Cardiac Resynchronization defibrillator with with all accessories - RA, RV and Bipolar LV leads and catheters CRT-D• LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial leadup to 5.8 Fr. and compatible with 6 Fr. Sheath• 40J delivered energy• Pulse width and Tilt : Programmable as per DFT• Heart Failure Congestion Monitoring Trends with Alerts• Small size below 35cc• Warranty : Minimum 5 years• Facility of Changing the shocking vector based on Over Current sensing• Special Sensing filter protection for T Wave over sensing (optional)• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional• Facility of specially coated Device for avoiding lead abrasion (optional)• CE - approved
25Cardiac Resynchronization defibrillator with with all accessories - RA, RV and Bipolar LV leads and catheters CRT-D• LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial leadup to 5.8 Fr. and compatible with 6 Fr. Sheath• 40J delivered energy• Pulse width and Tilt : Programmable as per DFT• Heart Failure Congestion Monitoring Trends with Alerts• Small size below 35cc• Warranty : Minimum 5 years• Facility of Changing the shocking vector based on Over Current sensing• Special Sensing filter protection for T Wave over sensing (optional)• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional• Facility of specially coated Device for avoiding lead abrasion (optional)• DCGI - approved
26Pacemaker with his bundle/left bundle pacing algorithm as single chamber pacemaker• lead profile up to 6 Fr.• USFDA /PMDA approved
27Pacemaker with his bundle/left bundle pacing algorithm as single chamber pacemaker• lead profile up to 6 Fr. • CE - approved
28Pacemaker with his bundle/left bundle pacing algorithm as single chamber pacemaker• lead profile up to 6 Fr.• DCGI - approved
29Pacemaker with his bundle/left bundle pacing algorithm as double chamber pacemaker• lead profile up to 6 Fr. • USFDA /PMDA approved
30Pacemaker with his bundle/left bundle pacing algorithm as double chamber pacemaker• lead profile up to 6 Fr. • CE - approved
31Pacemaker with his bundle/left bundle pacing algorithm as double chamber pacemaker• lead profile up to 6 Fr. • DCGI - approved
32Pacemaker with his bundle/left bundle pacing algorithm as CRT-P • lead profile up to 6 Fr. • USFDA/PMDA approved
33Pacemaker with his bundle/left bundle pacing algorithm as CRT-P • lead profile up to 6 Fr. • CE - approved
34Pacemaker with his bundle/left bundle pacing algorithm as CRT-P • lead profile up to 6 Fr. • DCGI- approved
35Pacemaker with his bundle/left bundle pacing algorithm as CRT-D• lead profile up to 6 Fr. • USFDA /PMDA approved
36Pacemaker with his bundle/left bundle pacing algorithm as CRT-D• lead profile up to 6 Fr. • CE approved
37Pacemaker with his bundle/left bundle pacing algorithm as CRT-D• lead profile up to 6 Fr. • DCGIapproved
38Pacemaker lead with peel away sheath only (without pulse generator) for the existing company providing complete pacemaker at RNT medical college • USFDA /PMDA - approved
39Pacemaker lead with peel away sheath only (without pulse generator) for the existing company providing complete pacemaker at RNT medical college • CE - approved
40Pacemaker lead with peel away sheath only (without pulse generator) for the existing company providing complete pacemaker at RNT medical college• DCGI - approved
41Pacemaker (PG) without lead and peel away sheathfor the existing company providing complete pacemaker at RNT medical college• USFDA /PMDA approved
42Pacemaker (PG) without lead and peel away sheathfor the existing company providing complete pacemaker at RNT medical college • CE - approved
43Pacemaker (PG) without lead and peel away sheathfor the existing company providing complete pacemaker at RNT medical college• DCGI - approved
44PTCA Balloon (semi compliant)With entry profile <0.016”, Hydrophilic coating and tapered tip, available in diameter ranging from 1.00 to 4.00 mm and lengths 8 mm to 20 mm• Core wire shaft for better push ability• USFDA /PMDA approved
45PTCA Balloon (semi compliant)With entry profile <0.016”, Hydrophilic coating and tapered tip, available in diameter ranging from 1.00 to 4.00 mm and lengths 8 mm to 20 mm• Core wire shaft for better push ability• CE-approved
46PTCA Balloon (semi compliant)With entry profile <0.016”, Hydrophilic coating and tapered tip, available in diameter ranging from 1.00 to 4.00 mm and lengths 8 mm to 20 mm• Core wire shaft for better push ability• DCGI-approved
47PTCA Balloon (Non compliant)With entry profile <0.016”, Hydrophilic coating and tapered tip, available in diameter ranging from 2.00 to 4.5 mm and lengths 5 mm to 20 mm• Core wire shaft for better push ability• USFDA /PMDA approved
48PTCA Balloon (Non compliant)With entry profile <0.016”, Hydrophilic coating and tapered tip, available in diameter ranging from 2.00 to 4.5 mm and lengths 5 mm to 20 mm• Core wire shaft for better push ability• CE-approved
49PTCA Balloon (Non compliant)With entry profile <0.016”, Hydrophilic coating and tapered tip, available in diameter ranging from 2.00 to 4.5 mm and lengths 5 mm to 20 mm• Core wire shaft for better push ability• DCGI-approved
50Special Valvuloplasty Balloon Catheter (Tyshek type) USFDA/CE approved • Diameter 4 mm to 35 mm• Length 20 to 60 mm• Nominal pressure< 4 ATM• Should have dog boning for precise position• USFDA /PMDA approved
51Special Valvuloplasty Balloon Catheter (Tyshek type) USFDA/CE approved • Diameter 4 mm to 35 mm• Length 20 to 60 mm• Nominal pressure< 4 ATM• Should have dog boning for precise position• CE - approved
52Special Valvuloplasty Balloon Catheter (Tyshek type) USFDA/CE approved • Diameter 4 mm to 35 mm• Length 20 to 60 mm• Nominal pressure< 4 ATM• Should have dog boning for precise position• DCGI - approved
53Special PTCA Balloon Catheter of Sizes 0.75 to 0.9 mm- • Should be available in variable balloon length 8-15 mm• USFDA /PMDA approved
54Special PTCA Balloon Catheter of Sizes 0.75 to 0.9 mm- • Should be available in variable balloon length 8-15 mm• CE – approved
55Special PTCA Balloon Catheter of Sizes 0.75 to 0.9 mm- • Should be available in variable balloon length 8-15 mm• DCGI - approved
56Special PTCA Balloon for CTO penetration• Diameter less than 1 mm • Length less than 9 mm• USFDA /PMDA approved
57Special PTCA Balloon for CTO penetration• Diameter less than 1 mm • Length less than 9 mm• CE - approved
58Special PTCA Balloon for CTO penetration• Diameter less than 1 mm • Length less than 9 mm• DCGI - approved
59Special PTCA Balloon Catheter of Sizes 0.85 mm non compliant super high pressure balloon dilatation catheter pressure from 23 bar to 28 bar RBP variable large mono rail system, Hydrophilic coated • USFDA /PMDA approved
60Special PTCA Balloon Catheter of Sizes 0.85 mm non compliant super high pressure balloon dilatation catheter pressure from 23 bar to 28 bar RBP variable large mono rail system, Hydrophilic coated • CE - approved
61Special PTCA Balloon Catheter of Sizes 0.85 mm non compliant super high pressure balloon dilatation catheter pressure from 23 bar to 28 bar RBP variable large mono rail system, Hydrophilic coated • DCGI - approved
62Zerofold PTCA Balloon• Available in all sizes and length• USFDA /PMDA approved
63Zerofold PTCA Balloon• Available in all sizes and length• CE - approved
64Zerofold PTCA Balloon• Available in all sizes and length• DCGI - approved
65Special PTCA Balloon for CTO-• Diameter should be 0.75 mm or less• USFDA /PMDA approved
66Special PTCA Balloon for CTO-• Diameter should be 0.75 mm or less• CE - approved
67Special PTCA Balloon for CTO-• Diameter should be 0.75 mm or less• DCGI - approved
68Ultra high pressureplaque modification device Dual layer/RBP 35 bars/ABP bars/ABP 45 bars strictly non-compliant (only10% growth)/ and for super high pressure PTCAUSFDA /PMDA approve
69Ultra high pressureplaque modification device Dual layer/RBP 35 bars/ABP bars/ABP 45 bars strictly non-compliant (only10% growth)/ and for super high pressure PTCACE approved
70Ultra high pressureplaque modification device Dual layer/RBP 35 bars/ABP bars/ABP 45 bars strictly non-compliant (only10% growth)/ and for super high pressure PTCADCGI approved
71Small Non-Compliant CTO balloon/diameter 0.85 m/ Lesion Entry Profile-0.016”/RBP-21 atm/ Hydrophilic coated/ Single Proximal makerUSFDA /PMDAapproved
72Small Non-Compliant CTO balloon/diameter 0.85 m/ Lesion Entry Profile-0.016”/RBP-21 atm/ Hydrophilic coated/ Single Proximal makerCE approved
73Small Non-Compliant CTO balloon/diameter 0.85 m/ Lesion Entry Profile-0.016”/RBP-21 atm/ Hydrophilic coated/ Single Proximal makerDCGI approved
74Semi complaint PTCA balloon with smallest entry profile of 0.585 mm; Tapered balloon shape, unique tri-fold wrapping technology,TR2 hydrophilic coating, available in lowest profile 1 mm diameterUSFDA /PMDA approved
75Semi complaint PTCA balloon with smallest entry profile of 0.585 mm; Tapered balloon shape, unique tri-fold wrapping technology,TR2 hydrophilic coating, available in lowest profile 1 mm diameterCE approved
76Semi complaint PTCA balloon with smallest entry profile of 0.585 mm; Tapered balloon shape, unique tri-fold wrapping technology,TR2 hydrophilic coating, available in lowest profile 1 mm diameterDCGI approved
77Non-CompliantPTCA balloon With Highest rbp UP TO 22 atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder angle to 32 deg; available in lowest profile 1.5 mm diameter USFDA /PMDA approved
78Non-CompliantPTCA balloon With Highest rbp UP TO 22 atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder angle to 32 deg; available in lowest profile 1.5 mm diameter CE approved
79Non-CompliantPTCA balloon With Highest rbp UP TO 22 atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder angle to 32 deg; available in lowest profile 1.5 mm diameter DCGI approved
80Non Compliant –balloon with nominal pressure of 12 atm and RBP of 22 atm .Flexibal thin distal tip with low entryprofile of 0.43 mm.Innovative triple layer ballon technology for high pressure resistance (outer layer of elastomer, middle layer of polyamide and inner most layer of elastomer) to provide outstanding flexibility and crossing performance. USFDA /PMDA approved
81Non Compliant –balloon with nominal pressure of 12 atm and RBP of 22 atm .Flexibal thin distal tip with low entryprofile of 0.43 mm.Innovative triple layer ballon technology for high pressure resistance (outer layer of elastomer, middle layer of polyamide and inner most layer of elastomer) to provide outstanding flexibility and crossing performance. CE approved
82Non Compliant –balloon with nominal pressure of 12 atm and RBP of 22 atm .Flexibal thin distal tip with low entryprofile of 0.43 mm.Innovative triple layer ballon technology for high pressure resistance (outer layer of elastomer, middle layer of polyamide and inner most layer of elastomer) to provide outstanding flexibility and crossing performance. DCGI approved
83Ultra low entry profile of 0.016” with hydrophilic coating for superior crossability . shorter and thinner radiopaque maker for lower crossing profile (length of 0.8 mm and thickness of 25 µm), flexible tip with short balloonbonding part of 0.4 mm. Robust and improve core wire shaft for better push ability. Smallest diameter of 1.00 mm and 5 mm length.USFDA /PMDA approved
84Ultra low entry profile of 0.016” with hydrophilic coating for superior crossability . shorter and thinner radiopaque maker for lower crossing profile (length of 0.8 mm and thickness of 25 µm), flexible tip with short balloonbonding part of 0.4 mm. Robust and improve core wire shaft for better push ability. Smallest diameter of 1.00 mm and 5 mm length.CE approved
85Ultra low entry profile of 0.016” with hydrophilic coating for superior crossability . shorter and thinner radiopaque maker for lower crossing profile (length of 0.8 mm and thickness of 25 µm), flexible tip with short balloonbonding part of 0.4 mm. Robust and improve core wire shaft for better push ability. Smallest diameter of 1.00 mm and 5 mm length.DCGI approved
86Non Compliant PTCA Balloon Dilatation Catheter• Tip entry profile < 0.016” (0.41 mm) Ultra low tip entry profile • Shaft diameter : Proximal < 1.95 F & Distal < 2.67 F• Guide Catheter – 5F compatible• Balloon material : Soft multi layered polyamide• Balloon fold Trifold (2-5mm)• Hydrophilic Coating : Selective Hydrophilic coating at distal shaft including balloon tip• Length : (mm) 6 to30• Diameter (mm) : 2 to5.0• Nominal Pressure : 12 atm• Rated Pressure Brust (RBP) – 20 atm (18 atm for 5 mm)• Diameter growth between nominal and rated brust pressure less than 6%• Two Platinum – Iridium marks• Shaft Length : > 140 mm• USFDA /PMDA approved
87Non Compliant PTCA Balloon Dilatation Catheter• Tip entry profile < 0.016” (0.41 mm) Ultra low tip entry profile • Shaft diameter : Proximal < 1.95 F & Distal < 2.67 F• Guide Catheter – 5F compatible• Balloon material : Soft multi layered polyamide• Balloon fold Trifold (2-5mm)• Hydrophilic Coating : Selective Hydrophilic coating at distal shaft including balloon tip• Length : (mm) 6 to 30• Diameter (mm) : 2 to 5.0• Nominal Pressure : 12 atm• Rated Pressure Brust (RBP) – 20 atm (18 atm for 5 mm)• Diameter growth between nominal and rated brust pressure less than 6%• Two Platinum – Iridium marks• Shaft Length : > 140 mm• CE approved
88Non Compliant PTCA Balloon Dilatation Catheter• Tip entry profile < 0.016” (0.41 mm) Ultra low tip entry profile • Shaft diameter : Proximal < 1.95 F & Distal < 2.67 F• Guide Catheter – 5F compatible• Balloon material : Soft multi layered polyamide• Balloon fold Trifold (2-5mm)• Hydrophilic Coating : Selective Hydrophilic coating at distal shaft including balloon tip• Length : (mm) 6to 30• Diameter (mm) : 2 to 5.0• Nominal Pressure : 12 atm• Rated Pressure Brust (RBP) – 20 atm (18 atm for 5 mm)• Diameter growth between nominal and rated brust pressure less than 6%• Two Platinum – Iridium marks• Shaft Length : > 140 mm• DCGI approved
89Special PTCA Balloon for CTO lesions starting diameter 0.85 mm with RBP 16 atm or above. Balloon hypotube must be spiral-cut design for excellent force transmission from proximal shaft to distal tip. Quote both monorail (rapid exchange) or OTW balloons.USFDA /PMDAapproved
90Special PTCA Balloon for CTO lesions starting diameter 0.85 mm with RBP 16 atm or above. Balloon hypotube must be spiral-cut design for excellent force transmission from proximal shaft to distal tip. Quote both monorail (rapid exchange) or OTW balloons.CE approved
91Special PTCA Balloon for CTO lesions starting diameter 0.85 mm with RBP 16 atm or above. Balloon hypotube must be spiral-cut design for excellent force transmission from proximal shaft to distal tip. Quote both monorail (rapid exchange) or OTW balloons.DCGI approved
92Special PTCA Balloon ( Non-compliant) for post dilation. Must have diameter starting from 1.75 mm-5.0 mm. Balloon material must be nylon for controlled compliance. Quote both monorail (rapid exchange) or OTW balloons.USFDA /PMDAapproved
93Special PTCA Balloon ( Non-compliant) for post dilation. Must have diameter starting from 1.75 mm-5.0 mm. Balloon material must be nylon for controlled compliance. Quote both monorail (rapid exchange) or OTW balloons.CE approved
94Special PTCA Balloon ( Non-compliant) for post dilation. Must have diameter starting from 1.75 mm-5.0 mm. Balloon material must be nylon for controlled compliance. Quote both monorail (rapid exchange) or OTW balloons.DCGI approved
95High pressure Non-compliant PTCA Balloon for controlled plaque, expansion & apposition. Balloon must available in longest length up to 26 mm. Should have high RBP above 22 atm. Quote both monorail (rapid exchange) or OTW balloons.USFDA /PMDAapproved
96High pressure Non-compliant PTCA Balloon for controlled plaque, expansion & apposition. Balloon must available in longest length up to 26 mm. Should have high RBP above 22 atm. Quote both monorail (rapid exchange) or OTW balloons. CE approved.
97High pressure Non-compliant PTCA Balloon for controlled plaque, expansion & apposition. Balloon must available in longest length up to 26 mm. Should have high RBP above 22 atm. Quote both monorail (rapid exchange) or OTW balloons. DCGIapproved.
98• Angiographic Double Lumen Tracking Catheter-- 4F/5F/6F For various purpose.• USFDA /PMDAapproved
99• Angiographic Double Lumen Tracking Catheter-- 4F/5F/6F For various purpose.• CE - approved
100• Angiographic Double Lumen Tracking Catheter-- 4F/5F/6F For various purpose.• DCGI - approved
101SPECIAL PTCA GUIDE WIRE WITH DUAL COATING Should have distal hydrophilic coating and proximal hydrophobic coating.Should have wires with variable tip stiffness and variable shaft support tip load <1gm• USFDA /PMDAapproved
102SPECIAL PTCA GUIDE WIRE WITH DUAL COATING Should have distal hydrophilic coating and proximal hydrophobic coating.Should have wires with variable tip stiffness and variable shaft support tip load <1gm• CE- approved
103SPECIAL PTCA GUIDE WIRE WITH DUAL COATING Should have distal hydrophilic coating and proximal hydrophobic coating.Should have wires with variable tip stiffness and variable shaft support tip load <1gm• DCGI- approved
104HEAVY DUTY NITINOL ALLOY EXTRA SUPPORT WIRE (REGULAR LENGTH AND EXCHANGE LENGTH)- • 0.014 inches , Nitinol alloy , With angled tip -3-5 cm long• Tip with platinum/platinum alloy for optimum visualization• With TFE coating ,180 cm to 300cm• USFDA /PMDAapproved
105HEAVY DUTY NITINOL ALLOY EXTRA SUPPORT WIRE (REGULAR LENGTH AND EXCHANGE LENGTH)- • 0.014 inches , Nitinol alloy , With angled tip -3-5 cm long• Tip with platinum/platinum alloy for optimum visualization• With TFE coating ,180 cm to 300cm• CE - approved
106HEAVY DUTY NITINOL ALLOY EXTRA SUPPORT WIRE (REGULAR LENGTH AND EXCHANGE LENGTH)- • 0.014 inches , Nitinol alloy , With angled tip -3-5 cm long• Tip with platinum/platinum alloy for optimum visualization• With TFE coating ,180 cm to 300cm• DCGI - approved
107STEERABLE HIGH SUPPORT .014 INCH GUIDEWIRE (regular and exchange length)• PTFE/ duraglide coated , • Distal Radio-opaque tip 3 cm long• Straight and J curve, 180 cm to 300 cm long•USFDA /PMDAapproved
108STEERABLE HIGH SUPPORT .014 INCH GUIDEWIRE (regular and exchange length)• PTFE/ duraglide coated , • Distal Radio-opaque tip 3 cm long • Straight and J curve, 180 cm to 300 cm long•CE – approved
109STEERABLE HIGH SUPPORT .014 INCH GUIDEWIRE (regular and exchange length)• PTFE/ duraglide coated , • Distal Radio-opaque tip 3 cm long • Straight and J curve, 180 cm to 300 cm long• DCGI – approved
110PTCA WIRES WITH FACILITY OF BOOT LINKS FOR EXTENSION OF REGULAR WIRE -• USFDA /PMDAapproved
111PTCA WIRES WITH FACILITY OF BOOT LINKS FOR EXTENSION OF REGULAR WIRE -• CE – approved
112PTCA WIRES WITH FACILITY OF BOOT LINKS FOR EXTENSION OF REGULAR WIRE -• DCGI- approved
113EXTENSIION (DOC) WIRE FOR APPROVED REGULAR LENGTH PTCA GUIDE WIRES –• USFDA /PMDAapproved
114EXTENSIION (DOC) WIRE FOR APPROVED REGULAR LENGTH PTCA GUIDE WIRES –• CE - approved
115EXTENSIION (DOC) WIRE FOR APPROVED REGULAR LENGTH PTCA GUIDE WIRES –• DCGI - approved
116PENETRATION CATHETERS FOR CTO HAVING ROTATIONAL BLUNT PENETRATION –• USFDA /PMDAapproved
117PENETRATION CATHETERS FOR CTO HAVING ROTATIONAL BLUNT PENETRATION –• CE - approved
118PENETRATION CATHETERS FOR CTO HAVING ROTATIONAL BLUNT PENETRATION –• DCGI - approved
119Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil 22cm polymer sleeve lengthwith slip coat coating over the polymer sleeve, tip load1gand 0.8g,180cm length, tip radiopacity 3cm• USFDA /PMDAapproved
120Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil 22cm polymer sleeve lengthwith slip coat coating over the polymer sleeve, tip load1gand 0.8g,180cm length, tip radiopacity 3cm• CE - approved
121Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil 22cm polymer sleeve lengthwith slip coat coating over the polymer sleeve, tip load1gand 0.8g,180cm length, tip radiopacity 3cm• DCGI - approved
122Specialized PTCA Guide wire for CTO –stainless steel core without polymer cover with hydrophilic coating wire tip load varying from 1.7 to 8.7 gm.• USFDA /PMDAapproved
123Specialized PTCA Guide wire for CTO –stainless steel core without polymer cover with hydrophilic coating wire tip load varying from 1.7 to 8.7 gm.• CE - approved
124Specialized PTCA Guide wire for CTO –stainless steel core without polymer cover with hydrophilic coating wire tip load varying from 1.7 to 8.7 gm.• DCGI - approved
125Specialized PTCA Guide wire for CTO –stainless steel core with polymer cover with hydrophilic coating wire tip load varying from 0.8 to 4.8 gm.• USFDA /PMDAapproved
126Specialized PTCA Guide wire for CTO –stainless steel core with polymer cover with hydrophilic coating wire tip load varying from 0.8 to 4.8 gm.• CE - approved
127Specialized PTCA Guide wire for CTO –stainless steel core with polymer cover with hydrophilic coating wire tip load varying from 0.8 to 4.8 gm.• DCGI- approved
128Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil PTFE coating over the shaft ,tip load 3g,4.5g,6gand 12g, 180cm length with tip radiopacity 11cm• USFDA /PMDAapproved
129Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil PTFE coating over the shaft ,tip load 3g,4.5g,6gand 12g, 180cm length with tip radiopacity 11cm• CE - approved
130Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil PTFE coating over the shaft ,tip load 3g,4.5g,6gand 12g, 180cm length with tip radiopacity 11cm• DCGI – approved
131Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil and slip coat on the spring coil , PTFE coating over the shaft ,tip load 3g, 180cm length with tip radiopacity 11cm• USFDA /PMDAapproved
132Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil and slip coat on the spring coil , PTFE coating over the shaft ,tip load 3g, 180cm length with tip radiopacity 11cm• CE - approved
133Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil and slip coat on the spring coil , PTFE coating over the shaft ,tip load 3g, 180cm length with tip radiopacity 11cm• DCGI- approved
134Specialized PTCA Guide wire for retrograde approach & CTO –Non hydrophilic coated tapered tip .009\" with a tip load of 9gm and tip radiopacity of 20cm• USFDA /PMDAapproved
135Specialized PTCA Guide wire for retrograde approach & CTO –Non hydrophilic coated tapered tip .009\" with a tip load of 9gm and tip radiopacity of 20cm• CE - approved
136Specialized PTCA Guide wire for retrograde approach & CTO –Non hydrophilic coated tapered tip .009\" with a tip load of 9gm and tip radiopacity of 20cm• DCGI - approved
137Specialized PTCA Guidewire for retrograde approach & – Dedicated guidewire for externalization with tip load of 3g, length 330cm• USFDA /PMDAapproved
138Specialized PTCA Guidewire for retrograde approach & – Dedicated guidewire for externalization with tip load of 3g, length 330cm• CE - approved
139Specialized PTCA Guidewire for retrograde approach & – Dedicated guidewire for externalization with tip load of 3g, length 330cm• DCGI – approved
140Specialized PTCA Guide wire for retrograde approach & CTO– One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to 0.009\" l, tip load 9g ,180cm length, tip radiopacity 20cm• USFDA /PMDAapproved
141Specialized PTCA Guide wire for retrograde approach & CTO– One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to 0.009\" l, tip load 9g ,180cm length, tip radiopacity 20cm• CE - approved
142Specialized PTCA Guide wire for retrograde approach & CTO– One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to 0.009\" l, tip load 9g ,180cm length, tip radiopacity 20cm• DCGI - approved
143Specialized PTCA Guide wire for retrograde approach & CTO–0.014\" One Piece core wire with jointless spring coil, PTFE coating over the shaft, tip load .7g, 180cm length with tip radiopacity 4cm• USFDA /PMDAapproved
144Specialized PTCA Guide wire for retrograde approach & CTO–0.014\" One Piece core wire with jointless spring coil, PTFE coating over the shaft, tip load .7g, 180cm length with tip radiopacity 4cm• CE - approved
145Specialized PTCA Guide wire for retrograde approach & CTO–0.014\" One Piece core wire with jointless spring coil, PTFE coating over the shaft, tip load .7g, 180cm length with tip radiopacity 4cm• DCGI - approved
146Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil tapering to 0.009\"16cm polymer sleeve lengthwith slip coat coating over the polymer sleeve,190cm length tip radiopacity 16cm• USFDA /PMDAapproved
147Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil tapering to 0.009\"16cm polymer sleeve lengthwith slip coat coating over the polymer sleeve,190cm length tip radiopacity 16cm• CE - approved
148Specialized PTCA Guide wire for retrograde approach & CTO –0.014\" One Piece core wire with jointless spring coil tapering to 0.009\"16cm polymer sleeve lengthwith slip coat coating over the polymer sleeve,190cm length tip radiopacity 16cm• DCGI - approved
149Specialized PTCA Guide wire for retrograde approach & CTO –PTCA Guide Wire with SION TECH Technology -Tapered Type, Polymersleeve, TipLoad 0.6-1.0g• USFDA /PMDAapproved
150Specialized PTCA Guide wire for retrograde approach & CTO –PTCA Guide Wire with SION TECH Technology -Tapered Type, Polymersleeve, TipLoad 0.6-1.0g• CE - approved
151Specialized PTCA Guide wire for retrograde approach & CTO –PTCA Guide Wire with SION TECH Technology -Tapered Type, Polymersleeve, TipLoad 0.6-1.0g• DCGI- approved
152Specialized PTCA Guide wire for retrograde approach & CTO –0.010\" One Piece core wire with joint less Spring coil with SION TECH technology length 15cm , cone tipwith a tip load of1.7gm, 3.5gm and 4.5gm, 190cm length tip radiopacity 15cm,• USFDA /PMDAapproved
153Specialized PTCA Guide wire for retrograde approach & CTO –0.010\" One Piece core wire with joint less Spring coil with SION TECH technology length 15cm , cone tipwith a tip load of1.7gm, 3.5gm and 4.5gm, 190cm length tip radiopacity 15cm,• CE - approved
154Specialized PTCA Guide wire for retrograde approach & CTO –0.010\" One Piece core wire with joint less Spring coil with SION TECH technology length 15cm , cone tipwith a tip load of1.7gm, 3.5gm and 4.5gm, 190cm length tip radiopacity 15cm,• DCGI - approved
155PTCA Guide Wire-DuraSteel Stainless Steel for durability and excellent torque control, Full polymer jacket, Core to Tip Design for precise steering and tip control, various tip Loads 1.5 gm to 4.1.gm for complex anatomies, Hydrophilic coating for longer lasting Lubricity.• USFDA /PMDAapproved
156PTCA Guide Wire-DuraSteel Stainless Steel for durability and excellent torque control, Full polymer jacket, Core to Tip Design for precise steering and tip control, various tip Loads 1.5 gm to 4.1.gm for complex anatomies, Hydrophilic coating for longer lasting Lubricity.• CE - approved
157PTCA Guide Wire-DuraSteel Stainless Steel for durability and excellent torque control, Full polymer jacket, Core to Tip Design for precise steering and tip control, various tip Loads 1.5 gm to 4.1.gm for complex anatomies, Hydrophilic coating for longer lasting Lubricity.• DCGI - approved
158Workhorse Guide wire with Dura steel Core, Responses Core Grind Technology with Hydrophilic coating and 1cm uncoated distal tip for tactile feedback available in multiple variants with same tip load of 0.9gm• USFDA /PMDAapproved
159Workhorse Guide wire with Dura steel Core, Responses Core Grind Technology with Hydrophilic coating and 1cm uncoated distal tip for tactile feedback available in multiple variants with same tip load of 0.9gm• CE - approved
160Workhorse Guide wire with Dura steel Core, Responses Core Grind Technology with Hydrophilic coating and 1cm uncoated distal tip for tactile feedback available in multiple variants with same tip load of 0.9gm• DCGI - approved
161PTCA Guide Wire-Dura Steel Stainless Steel for durability and excellent torque control, Full polymer jacket, Core to Tip Design for precise steering and tip control, various tip Loads 0.8 gm to 1.2 gm for complex anatomies, Hydrophilic coating for longer lasting Lubricity.• USFDA /PMDAapproved
162PTCA Guide Wire-Dura Steel Stainless Steel for durability and excellent torque control, Full polymer jacket, Core to Tip Design for precise steering and tip control, various tip Loads 0.8 gm to 1.2 gm for complex anatomies, Hydrophilic coating for longer lasting Lubricity.• CE- approved
163PTCA Guide Wire-Dura Steel Stainless Steel for durability and excellent torque control, Full polymer jacket, Core to Tip Design for precise steering and tip control, various tip Loads 0.8 gm to 1.2 gm for complex anatomies, Hydrophilic coating for longer lasting Lubricity.• DCGI - approved
164Peripheral wire 0.014-• Stainless steel core wire• Hydrophilic & hydrophobic coating• Tip load – 3 gm & 6 gm• US FDA approved• Wire length- 190 cm & 300 cm• USFDA /PMDAapproved
165Peripheral wire 0.014-• Stainless steel core wire• Hydrophilic & hydrophobic coating• Tip load – 3 gm & 6 gm• US FDA approved• Wire length- 190 cm & 300 cm• CE - approved
166Peripheral wire 0.014-• Stainless steel core wire• Hydrophilic & hydrophobic coating• Tip load – 3 gm & 6 gm• US FDA approved• Wire length- 190 cm & 300 cm• DCGI - approved
167Peripheral wire 0.018-• 0.018” guide wire with Stainless steel core wire• Hydrophilic & hydrophobic coating• Tip load – 7.6 gm & 6.5 gm• US FDA approved• Wire length- 150 cm, 200 & 300 cm• USFDA /PMDAapproved
168Peripheral wire 0.018-• 0.018” guide wire with Stainless steel core wire• Hydrophilic & hydrophobic coating• Tip load – 7.6 gm & 6.5 gm• US FDA approved• Wire length- 150 cm, 200 & 300 cm• CE - approved
169Peripheral wire 0.018-• 0.018” guide wire with Stainless steel core wire• Hydrophilic & hydrophobic coating• Tip load – 7.6 gm & 6.5 gm• US FDA approved• Wire length- 150 cm, 200 & 300 cm• DCGI - approved
170CTO Wire 0.014”• 0.014” weighted tip CTO guide wire with stainless steel core• Hydrophilic & Hydrophobic coating• Tip load- 12gm, 18 gm, 25 gm, 30 gm• Wire lengths-190 cm & 300 cm• USFDA /PMDAapproved
171CTO Wire 0.014”• 0.014” weighted tip CTO guide wire with stainless steel core• Hydrophilic & Hydrophobic coating• Tip load- 12gm, 18 gm, 25 gm, 30 gm• Wire lengths-190 cm & 300 cm• CE - approved
172CTO Wire 0.014”• 0.014” weighted tip CTO guide wire with stainless steel core• Hydrophilic & Hydrophobic coating• Tip load- 12gm, 18 gm, 25 gm, 30 gm• Wire lengths-190 cm & 300 cm• DCGI - approved
173CTO Wire 0.018”• 0.018” weighted tip CTO guide wire with stainless steel core• Hydrophilic & Hydrophobic coating• Tip load- 12gm, 18 gm, 25 gm, 30 gm• USFDA /PMDAapprovedWire lengths-190 cm & 300 cm
174CTO Wire 0.018”• 0.018” weighted tip CTO guide wire with stainless steel core• Hydrophilic & Hydrophobic coating• Tip load- 12gm, 18 gm, 25 gm, 30 gm• CE-approvedWire lengths-190 cm & 300 cm
175CTO Wire 0.018”• 0.018” weighted tip CTO guide wire with stainless steel core• Hydrophilic & Hydrophobic coating• Tip load- 12gm, 18 gm, 25 gm, 30 gm• DCGI- approvedWire lengths-190 cm & 300 cm
176Peripheral GW 0.035”• Moderate rail support• length - 180-260 cm• Tip- spring coil• USFDA /PMDAapproved
177Peripheral GW 0.035”• Moderate rail support• length - 180-260 cm• Tip- spring coil• CE- approved
178Peripheral GW 0.035”• Moderate rail support• length - 180-260 cm• Tip- spring coil• DCGI - approved
179Peripheral GW 0.035”• Extra support rail strength• length - 75-260 cm• Tip- spring coil• USFDA /PMDAapproved
180Peripheral GW 0.035”• Extra support rail strength• length - 75-260 cm• Tip- spring coil• CE- approved
181Peripheral GW 0.035”• Extra support rail strength• length - 75-260 cm• Tip- spring coil• DCGI - approved
182Backup Meier wire-0.035”• Should have extra stiff shaft to support AAA device• Should have very flexible and soft distal tip to avoid aortic perforation/vessel trauma• Should have radiopaque tip for excellent visibility, PTFE coated proximal shaft for frictionless advancement• Should have choice of“J” and“C” tip shape with 182 cmand 260/300 cm• USFDA /PMDAapproved
183Backup Meier wire-0.035”• Should have extra stiff shaft to support AAA device• Should have very flexible and soft distal tip to avoid aortic perforation/vessel trauma• Should have radiopaque tip for excellent visibility, PTFE coated proximal shaft for frictionless advancement• Should have choice of“J” and“C” tip shape with 182 cmand 260/300 cm• CE - approved
184Backup Meier wire-0.035”• Should have extra stiff shaft to support AAA device• Should have very flexible and soft distal tip to avoid aortic perforation/vessel trauma• Should have radiopaque tip for excellent visibility, PTFE coated proximal shaft for frictionless advancement• Should have choice of“J” and“C” tip shape with 182 cmand 260/300 cm• DCGI - approved
185Hydrophilic maker wire-0.035”-• Should have single piece core with radiopaque polyurethane jacket and Glidex coated hydrophilic coating.• 4 distal platinum magic markers spaced at 1 cm for improved visualization• Single piece core design to have better steer ability, push ability and torque transmission. • USFDA /PMDAapproved
186Hydrophilic maker wire-0.035”-• Should have single piece core with radiopaque polyurethane jacket and Glidex coated hydrophilic coating.• 4 distal platinum magic markers spaced at 1 cm for improved visualization• Single piece core design to have better steer ability, push ability and torque transmission. • CE- approved
187Hydrophilic maker wire-0.035”-• Should have single piece core with radiopaque polyurethane jacket and Glidex coated hydrophilic coating.• 4 distal platinum magic markers spaced at 1 cm for improved visualization• Single piece core design to have better steer ability, push ability and torque transmission. • DCGI - approved
188Balloons-NC workhorse(0.035” wire)• Should be non-compliant/ semi compliant. RBP of 20-24 atm (3-8 mm balloon), 14-18 atm (9-12 mm Balloon)• Should have high rated burst pressure with scratch/puncture resistant pebax material• Dual lumen shaft with balloon laser bonded and short atraumatic tapered tip• Should have lubricious medi –glide coating and balloon material• Should have good re-wrape and low tip profile• Should be 5F (3-7 mm balloon) /6F(8-10 mm balloon/7F (12 mm balloon) sheath and 0.035” wire compatible• Should have min lesion entry profile of 0.040” (1.016 mm)• Should have choice of long balloon length 20 mm to 200 mm• USFDA /PMDAapproved
189Balloons-NC workhorse(0.035” wire)• Should be non-compliant/ semi compliant. RBP of 20-24 atm (3-8 mm balloon), 14-18 atm (9-12 mm Balloon)• Should have high rated burst pressure with scratch/puncture resistant pebax material• Dual lumen shaft with balloon laser bonded and short atraumatic tapered tip• Should have lubricious medi –glide coating and balloon material• Should have good re-wrape and low tip profile• Should be 5F (3-7 mm balloon) /6F(8-10 mm balloon/7F (12 mm balloon) sheath and 0.035” wire compatible• Should have min lesion entry profile of 0.040” (1.016 mm)• Should have choice of long balloon length 20 mm to 200 mm• CE - approved
190Balloons-NC workhorse(0.035” wire)• Should be non-compliant/ semi compliant. RBP of 20-24 atm (3-8 mm balloon), 14-18 atm (9-12 mm Balloon)• Should have high rated burst pressure with scratch/puncture resistant pebax material• Dual lumen shaft with balloon laser bonded and short atraumatic tapered tip• Should have lubricious medi –glide coating and balloon material• Should have good re-wrape and low tip profile• Should be 5F (3-7 mm balloon) /6F(8-10 mm balloon/7F (12 mm balloon) sheath and 0.035” wire compatible• Should have min lesion entry profile of 0.040” (1.016 mm)• Should have choice of long balloon length 20 mm to 200 mm• DCGI - approved
191Balloons -0.018”/0.014” wire compatible –• Should be 4F/5F sheath and 0.018”/0.014” wire compatible with choice of OTW/Monorail delivery system• Should be non-compliant/ semi compliant.• Should have high rated burst pressure with scratch/puncture resistant pebax material• Should have lowest tip entry profile of not more than 0.022” and good 5 fold re-wrap design• Should haveexcellent coulum support with balloon laser bonded and short atraumatic tapered tip• Should have full length tapered core wire for enhancd pushability and kink resistance• Should have balloon length starting from 10 mm and balloon diameter from 3 mm to 10 mm. • USFDA /PMDAapproved
192Balloons -0.018”/0.014” wire compatible –• Should be 4F/5F sheath and 0.018”/0.014” wire compatible with choice of OTW/Monorail delivery system• Should be non-compliant/ semi compliant.• Should have high rated burst pressure with scratch/puncture resistant pebax material• Should have lowest tip entry profile of not more than 0.022” and good 5 fold re-wrap design• Should haveexcellent coulum support with balloon laser bonded and short atraumatic tapered tip• Should have full length tapered core wire for enhancd pushability and kink resistance• Should have balloon length starting from 10 mm and balloon diameter from 3 mm to 10 mm. • CE - approved
193Balloons -0.018”/0.014” wire compatible –• Should be 4F/5F sheath and 0.018”/0.014” wire compatible with choice of OTW/Monorail delivery system• Should be non-compliant/ semi compliant.• Should have high rated burst pressure with scratch/puncture resistant pebax material• Should have lowest tip entry profile of not more than 0.022” and good 5 fold re-wrap design• Should haveexcellent coulum support with balloon laser bonded and short atraumatic tapered tip• Should have full length tapered core wire for enhancd pushability and kink resistance• Should have balloon length starting from 10 mm and balloon diameter from 3 mm to 10 mm. • DCGI - approved
194Distal embolic protection device-Carotid/SVG-• (One size for all carotids)• Eccentric filter with nitinol loop for 360 degree wall apposition• Rx.014 6F sheath compatible • 190 cm extra support wire • Uniform micro pore size of 110 micron pore size with 1 mm pore free zone• Non thrombogenic nylon membrane with hydrophilic coating• Shouls allow optimal filtration in vessels 3-5.5 mm sizeUSFDA /PMDAapproved
195Distal embolic protection device-Carotid/SVG-• (One size for all carotids)• Eccentric filter with nitinol loop for 360 degree wall apposition• Rx.014 6F sheath compatible • 190 cm extra support wire • Uniform micro pore size of 110 micron pore size with 1 mm pore free zone• Non thrombogenic nylon membrane with hydrophilic coating• Shouls allow optimal filtration in vessels 3-5.5 mm size• CE- approved
196Distal embolic protection device-Carotid/SVG-• (One size for all carotids)• Eccentric filter with nitinol loop for 360 degree wall apposition• Rx.014 6F sheath compatible • 190 cm extra support wire • Uniform micro pore size of 110 micron pore size with 1 mm pore free zone• Non thrombogenic nylon membrane with hydrophilic coating• Shouls allow optimal filtration in vessels 3-5.5 mm size• DCGI- approved
197Balloon expandable stent-Renal (small Diameter)-• Should be low profile, 6F guide and 0.014” wire compatible, monorail system• Should have high consistent radial strength, high flexibility, enhanced radiopacity• Should have architecture which offers excellent lumen coverage and conformability• Should have increased support and radial strength and proximal end for ostial lesion• Stent should be premounted on semicompliant balloon catheter • Stent Dia 4-7 mm, length 15 & 19, catheter length 90 & 150 cm.• Should have crimping technology which ensures no stent slippage from balloon.• USFDA /PMDAapproved
198Balloon expandable stent-Renal (small Diameter)-• Should be low profile, 6F guide and 0.014” wire compatible, monorail system• Should have high consistent radial strength, high flexibility, enhanced radiopacity• Should have architecture which offers excellent lumen coverage and conformability• Should have increased support and radial strength and proximal end for ostial lesion• Stent should be premounted on semicompliant balloon catheter • Stent Dia 4-7 mm, length 15 & 19, catheter length 90 & 150 cm.• Should have crimping technology which ensures no stent slippage from balloon.• CE - approved
199Balloon expandable stent-Renal (small Diameter)-• Should be low profile, 6F guide and 0.014” wire compatible, monorail system• Should have high consistent radial strength, high flexibility, enhanced radiopacity• Should have architecture which offers excellent lumen coverage and conformability• Should have increased support and radial strength and proximal end for ostial lesion• Stent should be premounted on semicompliant balloon catheter • Stent Dia 4-7 mm, length 15 & 19, catheter length 90 & 150 cm.• Should have crimping technology which ensures no stent slippage from balloon.• DCGI - approved
200Balloon Expandable Stent- Large diameter-• Should have high consistent radial strength, high flexibility, enhanced radiopacity• Should have architecture which offers excellent lumen coverage and conformability• Should have low foreshortening, low recoil.• Stent should be premounted on non compliant balloon catheter to avoid dogboning and proper scaffolding• Should have dual lumen catheter design for faster deflation• Stent Dia 5-10 mm, length 27,37,57, catheter length 135 cm.• Should have crimping technology which ensures no stent slippage from balloon.• USFDA /PMDAapproved
201Balloon Expandable Stent- Large diameter-• Should have high consistent radial strength, high flexibility, enhanced radiopacity• Should have architecture which offers excellent lumen coverage and conformability• Should have low foreshortening, low recoil.• Stent should be premounted on non compliant balloon catheter to avoid dogboning and proper scaffolding• Should have dual lumen catheter design for faster deflation• Stent Dia 5-10 mm, length 27,37,57, catheter length 135 cm.• Should have crimping technology which ensures no stent slippage from balloon.• CE - approved
202Balloon Expandable Stent- Large diameter-• Should have high consistent radial strength, high flexibility, enhanced radiopacity• Should have architecture which offers excellent lumen coverage and conformability• Should have low foreshortening, low recoil.• Stent should be premounted on non compliant balloon catheter to avoid dogboning and proper scaffolding• Should have dual lumen catheter design for faster deflation• Stent Dia 5-10 mm, length 27,37,57, catheter length 135 cm.• Should have crimping technology which ensures no stent slippage from balloon.• DCGI - approved
203Self expandable stent for carotid artery stenting-• Self expending elgilloy stent with closed cell design/ auto tapered design.• Monorail, 0.014” wire & 6F sheath compatible• Recons trainable braided stent• Shaft length 135 cm• Dia-6-9 mm• USFDA /PMDAapproved
204Self expandable stent for carotid artery stenting-• Self expending elgilloy stent with closed cell design/ auto tapered design.• Monorail, 0.014” wire & 6F sheath compatible• Recons trainable braided stent• Shaft length 135 cm• Dia-6-9 mm• CE - approved
205Self expandable stent for carotid artery stenting-• Self expending elgilloy stent with closed cell design/ auto tapered design.• Monorail, 0.014” wire & 6F sheath compatible• Recons trainable braided stent• Shaft length 135 cm• Dia-6-9 mm• DCGI - approved
206Self expandable stent-• Should be laser cut self expending nitinol stent with proximal end distal makers• Should have hybrid cell design which promotes a balance of radial strength and flexibility.• Should have controlled release/deployment mechanism to ensure precise placement and low foreshortening.• Should be 6F sheath and 0.035” wire compatible across sent size matrix.• USFDA /PMDAapproved
207Self expandable stent-• Should be laser cut self expending nitinol stent with proximal end distal makers• Should have hybrid cell design which promotes a balance of radial strength and flexibility.• Should have controlled release/deployment mechanism to ensure precise placement and low foreshortening.• Should be 6F sheath and 0.035” wire compatible across sent size matrix.• CE - approved
208Self expandable stent-• Should be laser cut self expending nitinol stent with proximal end distal makers• Should have hybrid cell design which promotes a balance of radial strength and flexibility.• Should have controlled release/deployment mechanism to ensure precise placement and low foreshortening.• Should be 6F sheath and 0.035” wire compatible across sent size matrix.• DCGI - approved
209Peripheral self expanding drug eluting stent-• Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA• Triaxial delivery system• Hybrid cell architecture with open and close celldesisn• Easy deployment with thumbwheel & pull grip• 6F sheath compatibility• Dia-6 &10 mm• Length – 40,60,80,100,120 mm• USFDA /PMDAapproved
210Peripheral self expanding drug eluting stent-• Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA• Triaxial delivery system• Hybrid cell architecture with open and close celldesisn• Easy deployment with thumbwheel & pull grip• 6F sheath compatibility• Dia-6 &10 mm• Length – 40,60,80,100,120 mm• CE approved
211Peripheral self expanding drug eluting stent-• Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA• Triaxial delivery system• Hybrid cell architecture with open and close celldesisn• Easy deployment with thumbwheel & pull grip• 6F sheath compatibility• Dia-6 &10 mm• Length – 40,60,80,100,120 mm• DCGI- approved
212Peripheral self expanding stent SFA-• Easy development with thumbwheel & pull grip• 6F sheath compatibility• Dia- 5,6,7,8mm• Length – 40,60,80,100,120,150 mm• USFDA /PMDAapproved
213Peripheral self expanding stent SFA-• Easy development with thumbwheel & pull grip• 6F sheath compatibility• Dia- 5,6,7,8mm• Length – 40,60,80,100,120,150 mm• CE- approved
214Peripheral self expanding stent SFA-• Easy development with thumbwheel & pull grip• 6F sheath compatibility• Dia- 5,6,7,8mm• Length – 40,60,80,100,120,150 mm• DCGI- approved
215PVA Particles-• Should be made of polyvinyalcohol• Should have uniquely shaped and consistent sized particles.• USFDA /PMDAapproved
216PVA Particles-• Should be made of polyvinyalcohol• Should have uniquely shaped and consistent sized particles.• CE - approved
217PVA Particles-• Should be made of polyvinyalcohol• Should have uniquely shaped and consistent sized particles.• DCGI - approved
218ASD CLOSURE DEVICES WITH DELIVERY SYSTEM• Approved for pediatric/adult use• Device made of biologically inert material• Self-centering, detachable device with delivery• Cable• Polyester fabric integrated in each disc. • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • Available in all the sizes (6 mm – 40 mm)• USFDA /PMDAapproved
219ASD CLOSURE DEVICES WITH DELIVERY SYSTEM• Approved for pediatric/adult use• Device made of biologically inert material• Self-centering, detachable device with delivery• Cable• Polyester fabric integrated in each disc. • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • Available in all the sizes (6 mm – 40 mm)• CE - approved
220ASD CLOSURE DEVICES WITH DELIVERY SYSTEM• Approved for pediatric/adult use• Device made of biologically inert material• Self-centering, detachable device with delivery• Cable• Polyester fabric integrated in each disc. • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • Available in all the sizes (6 mm – 40 mm)• DCGI - approved
221ASD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM• USFDA /PMDAapproved
222ASD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM• CE - approved
223ASD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM• DCGI - approved
224DELIVERY SHEATH FOR ASD CLOSURE DEVICE –• Compatible with the device mentioned above• USFDA /PMDAapproved
225DELIVERY SHEATH FOR ASD CLOSURE DEVICE –• Compatible with the device mentioned above• CE- approved
226DELIVERY SHEATH FOR ASD CLOSURE DEVICE –• Compatible with the device mentioned above• DCGI - approved
227ASD Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh sewn with PTFE membrane available in all sizes• USFDA /PMDAapproved
228ASD Closure device with delivery system :-coated with titanium nitride (TiN)Soft woven nitinol mesh sewn with PTFE membrane available in all sizes• CE - approved
229ASD Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh sewn with PTFE membrane available in all sizes• DCGI - approved
230ASD - Multi Fenestrated (Cribriform) Occluders, • self-expandable double disc made up of soft nitinol wire mesh• two flat discs and waist of 3mm. • matched disc diameters • Polyester fabric sewn into each disc • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • Available in all the sizes (6 mm – 40mm)• USFDA /PMDAapproved
231ASD - Multi Fenestrated (Cribriform) Occluders, • self-expandable double disc made up of soft nitinol wire mesh• two flat discs and waist of 3mm. • matched disc diameters • Polyester fabric sewn into each disc • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • Available in all the sizes (6 mm – 40mm)• CE - approved
232ASD - Multi Fenestrated (Cribriform) Occluders, • self-expandable double disc made up of soft nitinol wire mesh• two flat discs and waist of 3mm. • matched disc diameters • Polyester fabric sewn into each disc • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • Available in all the sizes (6 mm – 40mm)• DCGI - approved
233LEFT ATRIAL APPENDAGE CLOSURE DEVICE• USFDA /PMDAapproved
234LEFT ATRIAL APPENDAGE CLOSURE DEVICE• CE - approved
235LEFT ATRIAL APPENDAGE CLOSURE DEVICE• DCGI- approved
236PFO CLOSURE DEVICES WITH DELIVERY SYSTEM• Approved for pediatric/adult use• Device made of biologically inert material• Available in all the sizes• USFDA /PMDAapproved
237PFO CLOSURE DEVICES WITH DELIVERY SYSTEM• Approved for pediatric/adult use• Device made of biologically inert material• Available in all the sizes• CE - approved
238PFO CLOSURE DEVICES WITH DELIVERY SYSTEM• Approved for pediatric/adult use• Device made of biologically inert material• Available in all the sizes• DCGI - approved
239PFO CLOSURE DEVICES WITHOUT DELIVERY SYSTEM –• USFDA /PMDAapproved
240PFO CLOSURE DEVICES WITHOUT DELIVERY SYSTEM –• CE- approved
241PFO CLOSURE DEVICES WITHOUT DELIVERY SYSTEM –• D CGI- approved
242DELIVERY SHEATH FOR PFO CLOSURE DEVICE –• Compatible with the device above • USFDA /PMDAapproved
243DELIVERY SHEATH FOR PFO CLOSURE DEVICE –• Compatible with the device above • CE - approved
244DELIVERY SHEATH FOR PFO CLOSURE DEVICE –• Compatible with the device above • DCGI - approved
245SIZING BALLOON FOR DEVICE CLOSURE – CIRCULAR SHAPE• USFDA /PMDAapproved
246SIZING BALLOON FOR DEVICE CLOSURE – CIRCULAR SHAPE• CE - approved
247SIZING BALLOON FOR DEVICE CLOSURE – CIRCULAR SHAPE• DCGI- approved
248SIZING BALLOON FOR DEVICE CLOSURE – OVAL SHAPED• USFDA /PMDAapproved
249SIZING BALLOON FOR DEVICE CLOSURE – OVAL SHAPED• CE- approved
250SIZING BALLOON FOR DEVICE CLOSURE – OVAL SHAPED• DCGI - approved
251SIZING PLATE FOR DEVICE CLOSURE –• USFDA /PMDAapproved
252SIZING PLATE FOR DEVICE CLOSURE –• CE -approved
253SIZING PLATE FOR DEVICE CLOSURE –• DCGI-approved
254DELIVERY CABLE FOR ASD/VSD/PDA DEVICES –• USFDA /PMDAapproved
255DELIVERY CABLE FOR ASD/VSD/PDA DEVICES –• CE- approved
256DELIVERY CABLE FOR ASD/VSD/PDA DEVICES –• DCGI- approved
257RETRIEVERS FOR ASD/VSD/PDA DEVICES –• USFDA /PMDAapproved
258RETRIEVERS FOR ASD/VSD/PDA DEVICES –• CE- approved
259RETRIEVERS FOR ASD/VSD/PDA DEVICES –• DCGI- approved
260SHEATH FOR RETRIVAL OF DEVICES –• USFDA /PMDAapproved
261SHEATH FOR RETRIVAL OF DEVICES –• CE- approved
262SHEATH FOR RETRIVAL OF DEVICES –• DCGI- approved
263AMPLATZER PLUG-• USFDA /PMDAapproved
264AMPLATZER PLUG-• CE- approved
265AMPLATZER PLUG-• DCGI- approved
266LEFT ATRIAL APENDAGE CLOSURE DEVICE-• USFDA /PMDAapproved
267LEFT ATRIAL APENDAGE CLOSURE DEVICE-• CE- approved
268LEFT ATRIAL APENDAGE CLOSURE DEVICE-• DCGI- approved
269VSD CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use• Device made of biologically inert material • Self-centering, detachable device with delivery cable • Available in all the sizes (6 mm – 40 mm)• USFDA /PMDAapproved
270VSD CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use• Device made of biologically inert material • Self-centering, detachable device with delivery cable • Available in all the sizes (6 mm – 40 mm)• CE-approved
271VSD CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use• Device made of biologically inert material • Self-centering, detachable device with delivery cable • Available in all the sizes (6 mm – 40 mm)• DCGI-approved
272VSD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM –• USFDA /PMDAapproved
273VSD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM –• CE-approved
274VSD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM –• DCGI-approved
275DELIVERY SHEATH FOR VSD CLOSURE DEVICE –• Compatible with the device in item above• USFDA /PMDAapproved
276DELIVERY SHEATH FOR VSD CLOSURE DEVICE –• Compatible with the device in item above• CE-approved
277DELIVERY SHEATH FOR VSD CLOSURE DEVICE –• Compatible with the device in item above• DCGI-approved
278VSD Closure device with delivery system :- Elongatable waist Soft Woven mesh Low delivery profile as low as 4F and maximum upo to 7 FDouble sided screw for retrograde or antegrade approachAvailable in all sizes• USFDA /PMDAapproved
279VSD Closure device with delivery system :-Elongatable waist Soft Woven mesh Low delivery profile as low as 4F and maximum upo to 7 FDouble sided screw for retrograde or antegrade approachAvailable in all sizes• CE-approved
280VSD Closure device with delivery system :- Elongatable waist Soft Woven meshLow delivery profile as low as 4F and maximum upo to 7 FDouble sided screw for retrograde or antegrade approachAvailable in all sizes• DCGI-approved
281Membranous VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane• Non concentric design • The device should be delivered using a pusher catheter from venous approch • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• USFDA /PMDAapproved
282Membranous VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane• Non concentric design • The device should be delivered using a pusher catheter from venous approch • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• CE-approved
283Membranous VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane• Non concentric design • The device should be delivered using a pusher catheter from venous approch • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• DCGI-approved
284Muscular VSD Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh; sewn with PTFE membrane• Symmetric, Asymmetric and eccentric forms Waist length should be 7 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• USFDA /PMDAapproved
285Muscular VSD Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh; sewn with PTFE membrane• Symmetric, Asymmetric and eccentric forms Waist length should be 7 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• CE-approved
286Muscular VSD Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh; sewn with PTFE membrane• Symmetric, Asymmetric and eccentric forms Waist length should be 7 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• DCGI-approved
287Muscular VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane• Symmetric, double discWaist length should be 7 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• USFDA /PMDAapproved
288Muscular VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane• Symmetric, double discWaist length should be 7 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• CE-approved
289Muscular VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane• Symmetric, double discWaist length should be 7 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• DCGI-approved
290Post infarction Muscular VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane• Symmetric, double disc• Waist length should be 10 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• USFDA /PMDAapproved
291Post infarction Muscular VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane• Symmetric, double disc• Waist length should be 10 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• CE-approved
292Post infarction Muscular VSD Closure device with delivery system :- Soft woven nitinol mesh; sewn with PTFE membrane• Symmetric, double disc• Waist length should be 10 mm • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • available in all sizes• DCGI-approved
293PDA CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use• Device made of biologically inert material (nitinol)• Self-centering, detachable device with delivery• cable• Polyester fabric integrated in each disc. • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR conditional up to 3 Tesla • Available in all the sizes• USFDA /PMDAapproved
294PDA CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use• Device made of biologically inert material (nitinol)• Self-centering, detachable device with delivery• cable• Polyester fabric integrated in each disc. • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR conditional up to 3 Tesla • Available in all the sizes• CE-approved
295PDA CLOSURE DEVICES WITH DELIVERY SYSTEM • Approved for pediatric/adult use• Device made of biologically inert material (nitinol)• Self-centering, detachable device with delivery• cable• Polyester fabric integrated in each disc. • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR conditional up to 3 Tesla • Available in all the sizes• DCGI-approved
296PDA CLOSURE DEVICES WITHOUT DELIVERY SYSTEM• USFDA /PMDAapproved
297PDA CLOSURE DEVICES WITHOUT DELIVERY SYSTEM• CE-approved
298PDA CLOSURE DEVICES WITHOUT DELIVERY SYSTEM• DCGI-approved
299DELIVERY SHEATH FOR PDA CLOSURE DEVICE –• Compatible with the device mentioned above• USFDA /PMDAapproved
300DELIVERY SHEATH FOR PDA CLOSURE DEVICE –• Compatible with the device mentioned above• CE-approved
301DELIVERY SHEATH FOR PDA CLOSURE DEVICE –• Compatible with the device mentioned above• DCGI-approved
302PDA Closure device with delivery system :- coated with titanium nitride (TiN)Soft woven nitinol mesh; sewn with PTFE membraneAvailable in all sizes• USFDA /PMDAapproved
303PDA Closure device with delivery system :-oated with titanium nitride (TiN)Soft woven nitinol mesh; sewn with PTFE membraneAvailable in all sizes• CE-approved
304PDA Closure device with delivery system :-coated with titanium nitride (TiN)Soft woven nitinol mesh; sewn with PTFE membraneAvailable in all sizes• DCGI-approved
305PDA occluder with double disc :- • Made up of biologicallyinert material (nitinol)• Symmetric disc design• Fabric free technology• Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • USFDA /PMDAapproved
306PDA occluder with double disc :- • Made up of biologicallyinert material (nitinol)• Symmetric disc design• Fabric free technology• Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • CE-approved
307PDA occluder with double disc :- • Made up of biologicallyinert material (nitinol)• Symmetric disc design• Fabric free technology• Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • DCGI-approved
308PDA occluder with double disc (for neonates) :- • Made up of biologicallyinert material (nitinol)• Symmetric disc design – low profile with low profiledelivery catheter of 4 Fr.• Tightly woven single layer mesh • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • USFDA /PMDAapproved
309PDA occluder with double disc (for neonates) :- • Made up of biologicallyinert material (nitinol)• Symmetric disc design – low profile with low profiledelivery catheter of 4 Fr.• Tightly woven single layer mesh • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • CE-approved
310PDA occluder with double disc (for neonates) :- • Made up of biologicallyinert material (nitinol)• Symmetric disc design – low profile with low profiledelivery catheter of 4 Fr.• Tightly woven single layer mesh • Chemically treated to improve biocompatibility & reduce nickel (Ni) leaching.• MR. conditional up to 3 Tesla • DCGI-approved
311EMBOLISATION COILS (0.018 INCH) - • Sizes ranging from 2 x 2 to 15 x 15• USFDA /PMDAapproved
312EMBOLISATION COILS (0.018 INCH) - • Sizes ranging from 2 x 2 to 15 x 15• CEapproved
313EMBOLISATION COILS (0.018 INCH) - • Sizes ranging from 2 x 2 to 15 x 15• DCGIapproved
314Embolisation Coils - • Should be 0.014/0.018” compatible• Should be made of platinum with synthetic • fibres• Should be non tapering/straight• Should be MR compatible• Should be available in any or the following diameters: 2-10 mm • Should be of various lengths; the length of the coil at each diameter should be stated• USFDA /PMDAapproved
315Embolisation Coils - • Should be 0.014/0.018” compatible• Should be made of platinum with synthetic • fibres• Should be non tapering/straight• Should be MR compatible• Should be available in any or the following diameters: 2-10 mm • Should be of various lengths; the length of the coil at each diameter should be stated• CE-approved
316Embolisation Coils - • Should be 0.014/0.018” compatible• Should be made of platinum with synthetic • fibres• Should be non tapering/straight• Should be MR compatible• Should be available in any or the following diameters: 2-10 mm • Should be of various lengths; the length of the coil at each diameter should be stated• DCGI-approved
317Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters )With delivery system• USFDA /PMDAapproved
318Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters )With delivery system• CE-approved
319Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters )With delivery system• DCGI-approved
320PediatricFemoralSheath 4 Fr.• USFDA /PMDAapproved
321Catheters for paediatric intervention • 4 Fr.• JL/JR/MP/pigtail• USFDA /PMDAapproved
322Catheters for paediatric intervention • 4 Fr.• JL/JR/MP/pigtail• CE-approved
323Catheters for paediatric intervention • 4 Fr.• JL/JR/MP/pigtail• DCGI-approved
324BMV Balloon Catheter• Small tip to avoid perforation • Made of latex material• Longer length LA guide wire• 3lumensat proximal end.• USFDA /PMDAapproved
325BMV Balloon Catheter• Small tip to avoid perforation • Made of latex material• Longer length LA guide wire• 3lumensat proximal end.• CE-approved
326BMV Balloon Catheter• Small tip to avoid perforation • Made of latex material• Longer length LA guide wire• 3lumensat proximal end.• DCGI-approved
327Mullin sheath with dilator• USFDA /PMDAapproved
328Mullin sheath with dilator• CE-approved
329Mullin sheath with dilator• DCGI-approved
330Trans- septal needle.• USFDA /PMDAapproved
331Trans- septal needle.• CE-approved
332Trans- septal needle.• DCGI-approved
333BRS Stent• Scaffold Matarial- Bio resoreble PLLA (poly L-Lactide)• Scaffold Strut Thickness- 100 Um• Scaffold Diameters-2.75, 3.00, 3.25, 4.00 mm• Scaffold Length- 16,19,24,29,32,40 Top Coating Drug+Polymer• Drug – Sirolimus• Equivalent Drug Dose-1.25 ug/mm2• Polymer – Bioresorable PDLLA (Poly D, L-Lactide)Delivery System• Delivery System-Rapid exchange• Nominal Pressure (NP) – 9 atm• Rated Burst Pressure (RBP) -16 atm• Balloon Overhang - <1 mm• Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F for linage delivery system• Radiopaque Markers – 2-platinum/Iridium• Usable Catheter Length-142 cm• Guide Catheter Compatibility-6F,)Min.1D0.070”/1.8mm)• Max. Guide wire-0.014” (0.36 mm)• USFDA /PMDAapproved
334BRS Stent• Scaffold Matarial- Bio resoreble PLLA (poly L-Lactide)• Scaffold Strut Thickness- 100 Um• Scaffold Diameters-2.75, 3.00, 3.25, 4.00 mm• Scaffold Length- 16,19,24,29,32,40 Top Coating Drug+Polymer• Drug – Sirolimus• Equivalent Drug Dose-1.25 ug/mm2• Polymer – Bioresorable PDLLA (Poly D, L-Lactide)Delivery System• Delivery System-Rapid exchange• Nominal Pressure (NP) – 9 atm• Rated Burst Pressure (RBP) -16 atm• Balloon Overhang - <1 mm• Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F for linage delivery system• Radiopaque Markers – 2-platinum/Iridium• Usable Catheter Length-142 cm• Guide Catheter Compatibility-6F,)Min.1D0.070”/1.8mm)• Max. Guide wire-0.014” (0.36 mm)• CE-approved
335BRS Stent• Scaffold Matarial- Bio resoreble PLLA (poly L-Lactide)• Scaffold Strut Thickness- 100 Um• Scaffold Diameters-2.75, 3.00, 3.25, 4.00 mm• Scaffold Length- 16,19,24,29,32,40 Top Coating Drug+Polymer• Drug – Sirolimus• Equivalent Drug Dose-1.25 ug/mm2• Polymer – Bioresorable PDLLA (Poly D, L-Lactide)Delivery System• Delivery System-Rapid exchange• Nominal Pressure (NP) – 9 atm• Rated Burst Pressure (RBP) -16 atm• Balloon Overhang - <1 mm• Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F for linage delivery system• Radiopaque Markers – 2-platinum/Iridium• Usable Catheter Length-142 cm• Guide Catheter Compatibility-6F,)Min.1D0.070”/1.8mm)• Max. Guide wire-0.014” (0.36 mm)• DCGI-approved
336PTCA Inflation Device-• Efficient locking system to maintain high pressure• Rapid inflation and deflation• Clear barrel for easy visualization of de-bubbling• Luminescent analog pressure gauge (up to 30 atm)• Ergomatric and use friendly hand held design• Company’s name & logo has to be there on indeflator itself• USFDA /PMDAapproved
337PTCA Inflation Device-• Efficient locking system to maintain high pressure• Rapid inflation and deflation• Clear barrel for easy visualization of de-bubbling• Luminescent analog pressure gauge (up to 30 atm)• Ergomatric and use friendly hand held design• Company’s name & logo has to be there on indeflator itself• CE approved
338PTCA Inflation Device-• Efficient locking system to maintain high pressure• Rapid inflation and deflation• Clear barrel for easy visualization of de-bubbling• Luminescent analog pressure gauge (up to 30 atm)• Ergomatric and use friendly hand held design• Company’s name & logo has to be there on indeflator itself• DCGI approved
339High Pressure PTCA inflation device analog pressure gauge upto 55 atmUSFDA /PMDAapproved
340High Pressure PTCA inflation device analog pressure gauge upto 55 atmCE approved
341High Pressure PTCA inflation device analog pressure gauge upto 55 atmDCGI approved
342Haemostatic Y-Connector for PTCA-Push-pull Mechanism-• Should accommodate virtually all interventional devices• Luer connector at the guiding catheter end• Rotating adapter at the guiding catheter end• Should have bleed back safety mechanism• Stepwise control for open, semi open and closed position.• USFDA /PMDAapproved
343Haemostatic Y-Connector for PTCA-Push-pull Mechanism-• Should accommodate virtually all interventional devices• Luer connector at the guiding catheter end• Rotating adapter at the guiding catheter end• Should have bleed back safety mechanism• Stepwise control for open, semi open and closed position.• CE approved
344Haemostatic Y-Connector for PTCA-Push-pull Mechanism-• Should accommodate virtually all interventional devices• Luer connector at the guiding catheter end• Rotating adapter at the guiding catheter end• Should have bleed back safety mechanism• Stepwise control for open, semi open and closed position.• DCGI approved
345Haemostatic Y-Connector for PTCA-Rotational Mechanism-• Should accommodate virtually all interventional devices• Luer connector at the guiding catheter end• Rotating adapter at the guiding catheter end• Should have bleed back safety mechanism• USFDA approved
346Haemostatic Y-Connector for PTCA-Rotational Mechanism-• Should accommodate virtually all interventional devices• Luer connector at the guiding catheter end• Rotating adapter at the guiding catheter end• Should have bleed back safety mechanism• CE approved
347Haemostatic Y-Connector for PTCA-Rotational Mechanism-• Should accommodate virtually all interventional devices• Luer connector at the guiding catheter end• Rotating adapter at the guiding catheter end• Should have bleed back safety mechanism• DCGI approved
348T.R. Band (Radial Artery Hemostasis Device)- Consists of two balloon specially designed for spot compression of the radial puncture site.USFDA /PMDAapproved
349T.R. Band (Radial Artery Hemostasis Device)- Consists of two balloon specially designed for spot compression of the radial puncture site.CE approved
350T.R. Band (Radial Artery Hemostasis Device)- Consists of two balloon specially designed for spot compression of the radial puncture site.DCGI approved
351INTRAVASCULAR RETRIEVER-SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titaniumnitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (5-35 mm)• USFDA/PMDA approved
352INTRAVASCULAR RETRIEVER-SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titaniumnitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (5-35 mm)• CE approved
353INTRAVASCULAR RETRIEVER-SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titaniumnitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (5-35 mm)• DCGI approved
354INTRAVASCULAR RETRIEVER-Micro SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titaniumnitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (5-35 mm)• USFDA/PMDA approved
355INTRAVASCULAR RETRIEVER-Micro SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titaniumnitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (5-35 mm)• CE approved
356INTRAVASCULAR RETRIEVER-Micro SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titaniumnitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (5-35 mm)• DCGI approved
357Guide extension catheter- • Stainless steel Hypotube, • polymer catheter segment 1 X 1 wire braiding hydrophilic coated with radical coller, • 0.57” inner Diameter, & 0.067” outer diameter• USFDA/PMDA approved
358Guide extension catheter-•Stainless steel Hypotube, • polymer catheter segment 1 X 1 wire braiding hydrophilic coated with radical coller, • 0.57” inner Diameter, & 0.067” outer diameter• CE approved
359Guide extension catheter-•Stainless steel Hypotube, • polymer catheter segment 1 X 1 wire braiding hydrophilic coated with radical coller, • 0.57” inner Diameter, & 0.067” outer diameter• DCGI approved
360Swan Ganz Catheter- • latex silicon balloon,• infusion capacity 1.5cc, • 7Fr sheath compatibility, • effective length 1100 mm• USFDA/PMDA approved
361Swan Ganz Catheter- • latex silicon balloon,• infusion capacity 1.5cc, • 7Fr sheath compatibility, • effective length 1100 mm• CE approved
362Swan Ganz Catheter- • latex silicon balloon,• infusion capacity 1.5cc, • 7Fr sheath compatibility, • effective length 1100 mm• DCGI approved
363Special PTCA Balloon for CTO Lesions• starting diameter0.85 mm • RBP 16 atm or above.• low entry tip profile equal to or less than 0.015”. Balloon hypotube must be-spiral-cut design. Quote both Monorail (rapid exchange) or OTW balloons • USFDA/PMDA approved
364Special PTCA Balloon for CTO Lesions• starting diameter0.85 mm • RBP 16 atm or above.• low entry tip profile equal to or less than 0.015”. Balloon hypotube must be-spiral-cut design. Quote both Monorail (rapid exchange) or OTW balloons • CE approved
365Special PTCA Balloon for CTO Lesions• starting diameter0.85 mm • RBP 16 atm or above.• low entry tip profile equal to or less than 0.015”. Balloon hypotube must be-spiral-cut design. Quote both Monorail (rapid exchange) or OTW balloons • DCGI approved
366Special PTCA balloon (non-compliant). • diameter starting from 1.75 mm-5.0 mm.• Balloon material must be nylon for controlled compliance.• Quote both monorail (rapid exchange) or OTW balloons.• USFDA/PMDA approved
367Special PTCA balloon (non-compliant). • diameter starting from 1.75 mm-5.0 mm.• Balloon material must be nylon for controlled compliance.• Quote both monorail (rapid exchange) or OTW balloons.• CE approved
368Special PTCA balloon (non-compliant). • diameter starting from 1.75 mm-5.0 mm.• Balloon material must be nylon for controlled compliance.• Quote both monorail (rapid exchange) or OTW balloons.• DCGI approved

AI Tender Summary

OUR REF NO 34906678
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 10 Crore
LAST DATE 27-12-2022
Authority
Authority Name Medical College
Work Description Rate Contract Of Cardiology Items , Rate Contract Of Cardio Items , Radial Sheathwith Puncture Needle For Adults ( Sizes 4 - 11 Fr. ) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-Way Stopcock Snap-On / Click-Off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20G*2 Entry Needle ( Plastic Iv Catheter ) • Usfda / Pmda Approved , Radial Sheathwith Puncture Needle For Adults ( Sizes 4 - 11 Fr. ) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-Way Stopcock Snap-On / Click-Off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20G*2 Entry Needle ( Plastic Iv Catheter ) • Ce - Approved , Radial Sheathwith Puncture Needle For Adults ( Sizes 4 - 11 Fr. ) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-Way Stopcock Snap-On / Click-Off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20G*2 Entry Needle ( Plastic Iv Catheter ) • Dcgi Approved , Radial Sheath:- 4 To 7 Fr • 0.21” Gw Compatible • Length 11 Cm • 21 G Needle • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Maneuverability With Minimal Leakage • Cannula Made Of Two Thinner Layers Of Polyethylene • Color Codes For Easy French Size Identification • Usfda / Pmda Approved , Radial Sheath:- 4 To 7 Fr • 0.21” Gw Compatible • Length 11 Cm • 21 G Needle • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Maneuverability With Minimal Leakage • Cannula Made Of Two Thinner Layers Of Polyethylene • Color Codes For Easy French Size Identification • Ce- Approved , Radial Sheath:- 4 To 7 Fr • 0.21” Gw Compatible • Length 11 Cm • 21 G Needle • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Maneuverability With Minimal Leakage • Cannula Made Of Two Thinner Layers Of Polyethylene • Color Codes For Easy French Size Identification • Dcgi- Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size • Usfda / Pmda Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size • Ce -Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft ( Distal -2 Cm ) Offering Soft & Round Tip With Co-Axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size • Dcgi -Approved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 1.5 T Mri Compatible ( Full Body ) • Usfda / Pmda Approved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 1.5 T Mri Compatible ( Full Body ) • Ce- Approved , Dual Chamber Pacemaker ( Ddd ) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead •Standard Warranty Of Minimum 10 Yrs. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With 6 Fr.Peel Away Sheath • 1.5 T Mri Compatible ( Full Body ) • Dcgi -Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Usfda / Pmda Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Ce-Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7.6 Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Dcgi-Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Usfda / Pmda Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Ce- Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Dcgi - Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Usfda / Pmda Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Ce - Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At / Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Special Trigger Mode Biventricular Pacing In Presence Of At / Af • Facility Of Rf Telemetry • Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Dcgi - Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Usfda / Pmda Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Ce - Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With 6 Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing ( Optional ) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion ( Optional ) • Dcgi - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Single Chamber Pacemaker • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Single Chamber Pacemaker • Lead Profile Up To 6 Fr. • Ce - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Single Chamber Pacemaker • Lead Profile Up To 6 Fr. • Dcgi - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Double Chamber Pacemaker • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Double Chamber Pacemaker • Lead Profile Up To 6 Fr. • Ce - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Double Chamber Pacemaker • Lead Profile Up To 6 Fr. • Dcgi - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-P • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-P • Lead Profile Up To 6 Fr. • Ce - Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-P • Lead Profile Up To 6 Fr. • Dcgi- Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-D • Lead Profile Up To 6 Fr. • Usfda / Pmda Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-D • Lead Profile Up To 6 Fr. • Ce Approved , Pacemaker With His Bundle / Left Bundle Pacing Algorithm As Crt-D • Lead Profile Up To 6 Fr. • Dcgiapproved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Usfda / Pmda - Approved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Ce - Approved , Pacemaker Lead With Peel Away Sheath Only ( Without Pulse Generator ) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Dcgi - Approved , Pacemaker ( Pg ) Without Lead And Peel Away Sheathfor The Existing Company Providing Complete Pacemaker At Rnt Medical College • Usfda / Pmda Approved , Pacemaker ( Pg ) Without Lead And Peel Away Sheathfor The Existing Company Providing Complete Pacemaker At Rnt Medical College • Ce - Approved , Pacemaker ( Pg ) Without Lead And Peel Away Sheathfor The Existing Company Providing Complete Pacemaker At Rnt Medical College • Dcgi - Approved , Ptca Balloon ( Semi Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Usfda / Pmda Approved , Ptca Balloon ( Semi Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Ce-Approved , Ptca Balloon ( Semi Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Dcgi-Approved , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Usfda / Pmda Approved , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Ce-Approved , Ptca Balloon ( Non Compliant ) With Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm • Core Wire Shaft For Better Push Ability • Dcgi-Approved , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Usfda / Pmda Approved , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Ce - Approved , Special Valvuloplasty Balloon Catheter ( Tyshek Type ) Usfda / Ce Approved • Diameter 4 Mm To 35 Mm • Length 20 To 60 Mm • Nominal Pressure< 4 Atm • Should Have Dog Boning For Precise Position • Dcgi - Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Usfda / Pmda Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Ce – Approved , Special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm • Dcgi - Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Usfda / Pmda Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Ce - Approved , Special Ptca Balloon For Cto Penetration • Diameter Less Than 1 Mm • Length Less Than 9 Mm • Dcgi - Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Usfda / Pmda Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Ce - Approved , Special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Dcgi - Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Usfda / Pmda Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Ce - Approved , Zerofold Ptca Balloon • Available In All Sizes And Length • Dcgi - Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Usfda / Pmda Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Ce - Approved , Special Ptca Balloon For Cto- • Diameter Should Be 0.75 Mm Or Less • Dcgi - Approved , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Usfda / Pmda Approve , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Ce Approved , Ultra High Pressureplaque Modification Device Dual Layer / Rbp 35 Bars / Abp Bars / Abp 45 Bars Strictly Non-Compliant ( Only10% Growth ) / And For Super High Pressure Ptca Dcgi Approved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Usfda / Pmdaapproved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Ce Approved , Small Non-Compliant Cto Balloon / Diameter 0.85 M / Lesion Entry Profile-0.016” / Rbp-21 Atm / Hydrophilic Coated / Single Proximal Maker Dcgi Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Usfda / Pmda Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Ce Approved , Semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameter Dcgi Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Usfda / Pmda Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Ce Approved , Non-Compliantptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Dcgi Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Usfda / Pmda Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Ce Approved , Non Compliant –Balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm . Flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm. Innovative Triple Layer Ballon Technology For High Pressure Resistance ( Outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer ) To Provide Outstanding Flexibility And Crossing Performance. Dcgi Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Usfda / Pmda Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Ce Approved , Ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile ( Length Of 0.8 Mm And Thickness Of 25 ?M ) , Flexible Tip With Short Balloonbonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length. Dcgi Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6 To30 • Diameter ( Mm ) : 2 To5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Usfda / Pmda Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6 To 30 • Diameter ( Mm ) : 2 To 5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Ce Approved , Non Compliant Ptca Balloon Dilatation Catheter • Tip Entry Profile < 0.016” ( 0.41 Mm ) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F • Guide Catheter – 5F Compatible • Balloon Material : Soft Multi Layered Polyamide • Balloon Fold Trifold ( 2-5Mm ) • Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length : ( Mm ) 6To 30 • Diameter ( Mm ) : 2 To 5.0 • Nominal Pressure : 12 Atm • Rated Pressure Brust ( Rbp ) – 20 Atm ( 18 Atm For 5 Mm ) • Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6% • Two Platinum – Iridium Marks • Shaft Length : > 140 Mm • Dcgi Approved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved , Special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-Cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Dcgi Approved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved , Special Ptca Balloon ( Non-Compliant ) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Dcgi Approved , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Usfda / Pmdaapproved , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Ce Approved. , High Pressure Non-Compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. Dcgiapproved. , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Usfda / Pmdaapproved , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Ce - Approved , • Angiographic Double Lumen Tracking Catheter-- 4F / 5F / 6F For Various Purpose. • Dcgi - Approved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Usfda / Pmdaapproved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Ce- Approved , Special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1Gm • Dcgi- Approved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimum Visualization • With Tfe Coating , 180 Cm To 300Cm • Usfda / Pmdaapproved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimum Visualization • With Tfe Coating , 180 Cm To 300Cm • Ce - Approved , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length And Exchange Length ) - • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long • Tip With Platinum / Platinum Alloy For Optimum Visualization • With Tfe Coating , 180 Cm To 300Cm • Dcgi - Approved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long •Usfda / Pmdaapproved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long •Ce – Approved , Steerable High Support .014 Inch Guidewire ( Regular And Exchange Length ) • Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long • Dcgi – Approved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Usfda / Pmdaapproved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Ce – Approved , Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Dcgi- Approved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Usfda / Pmdaapproved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Ce - Approved , Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires – • Dcgi - Approved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Usfda / Pmdaapproved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Ce - Approved , Penetration Catheters For Cto Having Rotational Blunt Penetration – • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, Tip Load1gand 0.8G, 180Cm Length, Tip Radiopacity 3Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Ce - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. • Dcgi - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Ce - Approved , Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. • Dcgi- Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G, 180Cm Length With Tip Radiopacity 11Cm • Dcgi – Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, 180Cm Length With Tip Radiopacity 11Cm • Dcgi- Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Non Hydrophilic Coated Tapered Tip .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm • Dcgi - Approved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Usfda / Pmdaapproved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Ce - Approved , Specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3G, Length 330Cm • Dcgi – Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009 L, Tip Load 9G , 180Cm Length, Tip Radiopacity 20Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto– 0.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.014 One Piece Core Wire With Jointless Spring Coil Tapering To 0.00916Cm Polymer Sleeve Lengthwith Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm • Dcgi - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – Ptca Guide Wire With Sion Tech Technology -Tapered Type, Polymersleeve, Tipload 0.6-1.0G • Dcgi- Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Usfda / Pmdaapproved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Ce - Approved , Specialized Ptca Guide Wire For Retrograde Approach & Cto – 0.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tipwith A Tip Load Of1.7Gm, 3.5Gm And 4.5Gm, 190Cm Length Tip Radiopacity 15Cm, • Dcgi - Approved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Usfda / Pmdaapproved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Ce - Approved , Ptca Guide Wire-Durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Dcgi - Approved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Usfda / Pmdaapproved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Ce - Approved , Workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9Gm • Dcgi - Approved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Usfda / Pmdaapproved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Ce- Approved , Ptca Guide Wire-Dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity. • Dcgi - Approved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Usfda / Pmdaapproved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Ce - Approved , Peripheral Wire 0.014- • Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 3 Gm & 6 Gm • Us Fda Approved • Wire Length- 190 Cm & 300 Cm • Dcgi - Approved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Usfda / Pmdaapproved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Ce - Approved , Peripheral Wire 0.018- • 0.018” Guide Wire With Stainless Steel Core Wire • Hydrophilic & Hydrophobic Coating • Tip Load – 7.6 Gm & 6.5 Gm • Us Fda Approved • Wire Length- 150 Cm, 200 & 300 Cm • Dcgi - Approved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Usfda / Pmdaapproved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Ce - Approved , Cto Wire 0.014” • 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Wire Lengths-190 Cm & 300 Cm • Dcgi - Approved , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Usfda / Pmdaapproved Wire Lengths-190 Cm & 300 Cm , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Ce-Approved Wire Lengths-190 Cm & 300 Cm , Cto Wire 0.018” • 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core • Hydrophilic & Hydrophobic Coating • Tip Load- 12Gm, 18 Gm, 25 Gm, 30 Gm • Dcgi- Approved Wire Lengths-190 Cm & 300 Cm , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Usfda / Pmdaapproved , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Ce- Approved , Peripheral Gw 0.035” • Moderate Rail Support • Length - 180-260 Cm • Tip- Spring Coil • Dcgi - Approved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Usfda / Pmdaapproved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Ce- Approved , Peripheral Gw 0.035” • Extra Support Rail Strength • Length - 75-260 Cm • Tip- Spring Coil • Dcgi - Approved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Usfda / Pmdaapproved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Ce - Approved , Backup Meier Wire-0.035” • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation / Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Should Have Choice Of“J” And“C” Tip Shape With 182 Cmand 260 / 300 Cm • Dcgi - Approved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Usfda / Pmdaapproved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Ce- Approved , Hydrophilic Maker Wire-0.035”- • Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating. • 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization • Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Dcgi - Approved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Usfda / Pmdaapproved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Ce - Approved , Balloons-Nc Workhorse ( 0.035” Wire ) • Should Be Non-Compliant / Semi Compliant. Rbp Of 20-24 Atm ( 3-8 Mm Balloon ) , 14-18 Atm ( 9-12 Mm Balloon ) • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Lubricious Medi –Glide Coating And Balloon Material • Should Have Good Re-Wrape And Low Tip Profile • Should Be 5F ( 3-7 Mm Balloon ) / 6F ( 8-10 Mm Balloon / 7F ( 12 Mm Balloon ) Sheath And 0.035” Wire Compatible • Should Have Min Lesion Entry Profile Of 0.040” ( 1.016 Mm ) • Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm • Dcgi - Approved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Usfda / Pmdaapproved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Ce - Approved , Balloons -0.018” / 0.014” Wire Compatible – • Should Be 4F / 5F Sheath And 0.018” / 0.014” Wire Compatible With Choice Of Otw / Monorail Delivery System • Should Be Non-Compliant / Semi Compliant. • Should Have High Rated Burst Pressure With Scratch / Puncture Resistant Pebax Material • Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-Wrap Design • Should Haveexcellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip • Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance • Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Dcgi - Approved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size Usfda / Pmdaapproved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size • Ce- Approved , Distal Embolic Protection Device-Carotid / Svg- • ( One Size For All Carotids ) • Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition • Rx.014 6F Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone • Non Thrombogenic Nylon Membrane With Hydrophilic Coating • Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size • Dcgi- Approved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Usfda / Pmdaapproved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Ce - Approved , Balloon Expandable Stent-Renal ( Small Diameter ) - • Should Be Low Profile, 6F Guide And 0.014” Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion • Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Dcgi - Approved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Usfda / Pmdaapproved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Ce - Approved , Balloon Expandable Stent- Large Diameter- • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10 Mm, Length 27, 37, 57, Catheter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon. • Dcgi - Approved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Usfda / Pmdaapproved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Ce - Approved , Self Expandable Stent For Carotid Artery Stenting- • Self Expending Elgilloy Stent With Closed Cell Design / Auto Tapered Design. • Monorail, 0.014” Wire & 6F Sheath Compatible • Recons Trainable Braided Stent • Shaft Length 135 Cm • Dia-6-9 Mm • Dcgi - Approved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Usfda / Pmdaapproved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Ce - Approved , Self Expandable Stent- • Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility. • Should Have Controlled Release / Deployment Mechanism To Ensure Precise Placement And Low Foreshortening. • Should Be 6F Sheath And 0.035” Wire Compatible Across Sent Size Matrix. • Dcgi - Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Usfda / Pmdaapproved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Ce Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug / Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length – 40, 60, 80, 100, 120 Mm • Dcgi- Approved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Usfda / Pmdaapproved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Ce- Approved , Peripheral Self Expanding Stent Sfa- • Easy Development With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia- 5, 6, 7, 8Mm • Length – 40, 60, 80, 100, 120, 150 Mm • Dcgi- Approved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Usfda / Pmdaapproved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Ce - Approved , Pva Particles- • Should Be Made Of Polyvinyalcohol • Should Have Uniquely Shaped And Consistent Sized Particles. • Dcgi - Approved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Usfda / Pmdaapproved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Ce - Approved , Asd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40 Mm ) • Dcgi - Approved , Asd Closure Devices Without Delivery System • Usfda / Pmdaapproved , Asd Closure Devices Without Delivery System • Ce - Approved , Asd Closure Devices Without Delivery System • Dcgi - Approved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Usfda / Pmdaapproved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Ce- Approved , Delivery Sheath For Asd Closure Device – • Compatible With The Device Mentioned Above • Dcgi - Approved , Asd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Usfda / Pmdaapproved , Asd Closure Device With Delivery System :-Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Ce - Approved , Asd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes • Dcgi - Approved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Usfda / Pmdaapproved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Ce - Approved , Asd - Multi Fenestrated ( Cribriform ) Occluders, • Self-Expandable Double Disc Made Up Of Soft Nitinol Wire Mesh • Two Flat Discs And Waist Of 3Mm. • Matched Disc Diameters • Polyester Fabric Sewn Into Each Disc • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All The Sizes ( 6 Mm – 40Mm ) • Dcgi - Approved , Left Atrial Appendage Closure Device • Usfda / Pmdaapproved , Left Atrial Appendage Closure Device • Ce - Approved , Left Atrial Appendage Closure Device • Dcgi- Approved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Usfda / Pmdaapproved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Ce - Approved , Pfo Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Available In All The Sizes • Dcgi - Approved , Pfo Closure Devices Without Delivery System – • Usfda / Pmdaapproved , Pfo Closure Devices Without Delivery System – • Ce- Approved , Pfo Closure Devices Without Delivery System – • D Cgi- Approved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Usfda / Pmdaapproved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Ce - Approved , Delivery Sheath For Pfo Closure Device – • Compatible With The Device Above • Dcgi - Approved , Sizing Balloon For Device Closure – Circular Shape • Usfda / Pmdaapproved , Sizing Balloon For Device Closure – Circular Shape • Ce - Approved , Sizing Balloon For Device Closure – Circular Shape • Dcgi- Approved , Sizing Balloon For Device Closure – Oval Shaped • Usfda / Pmdaapproved , Sizing Balloon For Device Closure – Oval Shaped • Ce- Approved , Sizing Balloon For Device Closure – Oval Shaped • Dcgi - Approved , Sizing Plate For Device Closure – • Usfda / Pmdaapproved , Sizing Plate For Device Closure – • Ce -Approved , Sizing Plate For Device Closure – • Dcgi-Approved , Delivery Cable For Asd / Vsd / Pda Devices – • Usfda / Pmdaapproved , Delivery Cable For Asd / Vsd / Pda Devices – • Ce- Approved , Delivery Cable For Asd / Vsd / Pda Devices – • Dcgi- Approved , Retrievers For Asd / Vsd / Pda Devices – • Usfda / Pmdaapproved , Retrievers For Asd / Vsd / Pda Devices – • Ce- Approved , Retrievers For Asd / Vsd / Pda Devices – • Dcgi- Approved , Sheath For Retrival Of Devices – • Usfda / Pmdaapproved , Sheath For Retrival Of Devices – • Ce- Approved , Sheath For Retrival Of Devices – • Dcgi- Approved , Amplatzer Plug- • Usfda / Pmdaapproved , Amplatzer Plug- • Ce- Approved , Amplatzer Plug- • Dcgi- Approved , Left Atrial Apendage Closure Device- • Usfda / Pmdaapproved , Left Atrial Apendage Closure Device- • Ce- Approved , Left Atrial Apendage Closure Device- • Dcgi- Approved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Usfda / Pmdaapproved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Ce-Approved , Vsd Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes ( 6 Mm – 40 Mm ) • Dcgi-Approved , Vsd Closure Devices Without Delivery System – • Usfda / Pmdaapproved , Vsd Closure Devices Without Delivery System – • Ce-Approved , Vsd Closure Devices Without Delivery System – • Dcgi-Approved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Usfda / Pmdaapproved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Ce-Approved , Delivery Sheath For Vsd Closure Device – • Compatible With The Device In Item Above • Dcgi-Approved , Vsd Closure Device With Delivery System :- Elongatable Waist Soft Woven Mesh Low Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Usfda / Pmdaapproved , Vsd Closure Device With Delivery System :-Elongatable Waist Soft Woven Mesh Low Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Ce-Approved , Vsd Closure Device With Delivery System :- Elongatable Waist Soft Woven Meshlow Delivery Profile As Low As 4F And Maximum Upo To 7 Fdouble Sided Screw For Retrograde Or Antegrade Approachavailable In All Sizes • Dcgi-Approved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Membranous Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Non Concentric Design • The Device Should Be Delivered Using A Pusher Catheter From Venous Approch • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Asymmetric And Eccentric Forms Waist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Discwaist Length Should Be 7 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Usfda / Pmdaapproved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Ce-Approved , Post Infarction Muscular Vsd Closure Device With Delivery System :- Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane • Symmetric, Double Disc • Waist Length Should Be 10 Mm • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Available In All Sizes • Dcgi-Approved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Usfda / Pmdaapproved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Ce-Approved , Pda Closure Devices With Delivery System • Approved For Pediatric / Adult Use • Device Made Of Biologically Inert Material ( Nitinol ) • Self-Centering, Detachable Device With Delivery • Cable • Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr Conditional Up To 3 Tesla • Available In All The Sizes • Dcgi-Approved , Pda Closure Devices Without Delivery System • Usfda / Pmdaapproved , Pda Closure Devices Without Delivery System • Ce-Approved , Pda Closure Devices Without Delivery System • Dcgi-Approved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Usfda / Pmdaapproved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Ce-Approved , Delivery Sheath For Pda Closure Device – • Compatible With The Device Mentioned Above • Dcgi-Approved , Pda Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Usfda / Pmdaapproved , Pda Closure Device With Delivery System :-Oated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Ce-Approved , Pda Closure Device With Delivery System :-Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membraneavailable In All Sizes • Dcgi-Approved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Usfda / Pmdaapproved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Ce-Approved , Pda Occluder With Double Disc :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design • Fabric Free Technology • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Dcgi-Approved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Usfda / Pmdaapproved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Ce-Approved , Pda Occluder With Double Disc ( For Neonates ) :- • Made Up Of Biologicallyinert Material ( Nitinol ) • Symmetric Disc Design – Low Profile With Low Profiledelivery Catheter Of 4 Fr. • Tightly Woven Single Layer Mesh • Chemically Treated To Improve Biocompatibility & Reduce Nickel ( Ni ) Leaching. • Mr. Conditional Up To 3 Tesla • Dcgi-Approved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Usfda / Pmdaapproved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Ceapproved , Embolisation Coils ( 0.018 Inch ) - • Sizes Ranging From 2 X 2 To 15 X 15 • Dcgiapproved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Usfda / Pmdaapproved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Ce-Approved , Embolisation Coils - • Should Be 0.014 / 0.018” Compatible • Should Be Made Of Platinum With Synthetic • Fibres • Should Be Non Tapering / Straight • Should Be Mr Compatible • Should Be Available In Any Or The Following Diameters: 2-10 Mm • Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated • Dcgi-Approved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Usfda / Pmdaapproved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Ce-Approved , Coil Pusher Wire For 0.014 / 0.018” Coils, ( Compatible With The Quoted Micro Catheters ) With Delivery System • Dcgi-Approved , Pediatricfemoral Sheath 4 Fr. • Usfda / Pmdaapproved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Usfda / Pmdaapproved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Ce-Approved , Catheters For Paediatric Intervention • 4 Fr. • Jl / Jr / Mp / Pigtail • Dcgi-Approved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Usfda / Pmdaapproved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Ce-Approved , Bmv Balloon Catheter • Small Tip To Avoid Perforation • Made Of Latex Material • Longer Length La Guide Wire • 3Lumensat Proximal End. • Dcgi-Approved , Mullin Sheath With Dilator • Usfda / Pmdaapproved , Mullin Sheath With Dilator • Ce-Approved , Mullin Sheath With Dilator • Dcgi-Approved , Trans- Septal Needle. • Usfda / Pmdaapproved , Trans- Septal Needle. • Ce-Approved , Trans- Septal Needle. • Dcgi-Approved , Brs Stent • Scaffold Matarial- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Usfda / Pmdaapproved , Brs Stent • Scaffold Matarial- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Ce-Approved , Brs Stent • Scaffold Matarial- Bio Resoreble Plla ( Poly L-Lactide ) • Scaffold Strut Thickness- 100 Um • Scaffold Diameters-2.75, 3.00, 3.25, 4.00 Mm • Scaffold Length- 16, 19, 24, 29, 32, 40 Top Coating Drug+Polymer • Drug – Sirolimus • Equivalent Drug Dose-1.25 Ug / Mm2 • Polymer – Bioresorable Pdlla ( Poly D, L-Lactide ) Delivery System • Delivery System-Rapid Exchange • Nominal Pressure ( Np ) – 9 Atm • Rated Burst Pressure ( Rbp ) -16 Atm • Balloon Overhang - <1 Mm • Shaft Outer Diameter-Proximal : 2.13F, Distal : 2.7F For Linage Delivery System • Radiopaque Markers – 2-Platinum / Iridium • Usable Catheter Length-142 Cm • Guide Catheter Compatibility-6F, ) Min.1D0.070” / 1.8Mm ) • Max. Guide Wire-0.014” ( 0.36 Mm ) • Dcgi-Approved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Usfda / Pmdaapproved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Ce Approved , Ptca Inflation Device- • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergomatric And Use Friendly Hand Held Design • Company’S Name & Logo Has To Be There On Indeflator Itself • Dcgi Approved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Usfda / Pmdaapproved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Ce Approved , High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm Dcgi Approved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Usfda / Pmdaapproved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Ce Approved , Haemostatic Y-Connector For Ptca-Push-Pull Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi Open And Closed Position. • Dcgi Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Usfda Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Ce Approved , Haemostatic Y-Connector For Ptca-Rotational Mechanism- • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Dcgi Approved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Usfda / Pmdaapproved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Ce Approved , T.R. Band ( Radial Artery Hemostasis Device ) - Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Dcgi Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Usfda / Pmda Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Ce Approved , Intravascular Retriever-Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Dcgi Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Usfda / Pmda Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Ce Approved , Intravascular Retriever-Micro Snare ( ‘Amplatz Goosenesk’ Type ) - Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titaniumnitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop ( 5-35 Mm ) • Dcgi Approved , Guide Extension Catheter- • Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Usfda / Pmda Approved , Guide Extension Catheter- •Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Ce Approved , Guide Extension Catheter- •Stainless Steel Hypotube, • Polymer Catheter Segment 1 X 1 Wire Braiding Hydrophilic Coated With Radical Coller, • 0.57” Inner Diameter, & 0.067” Outer Diameter • Dcgi Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Usfda / Pmda Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Ce Approved , Swan Ganz Catheter- • Latex Silicon Balloon, • Infusion Capacity 1.5Cc, • 7Fr Sheath Compatibility, • Effective Length 1100 Mm • Dcgi Approved , Special Ptca Balloon For Cto Lesions • Starting Diameter0.85 Mm • Rbp 16 Atm Or Above. • Low Entry Tip Profile Equal To Or Less Than 0.015”. Balloon Hypotube Must Be-Spiral-Cut Design. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons • Usfda / Pmda Approved , Special Ptca Balloon For Cto Lesions • Starting Diameter0.85 Mm • Rbp 16 Atm Or Above. • Low Entry Tip Profile Equal To Or Less Than 0.015”. Balloon Hypotube Must Be-Spiral-Cut Design. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons • Ce Approved , Special Ptca Balloon For Cto Lesions • Starting Diameter0.85 Mm • Rbp 16 Atm Or Above. • Low Entry Tip Profile Equal To Or Less Than 0.015”. Balloon Hypotube Must Be-Spiral-Cut Design. Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons • Dcgi Approved , Special Ptca Balloon ( Non-Compliant ) . • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Usfda / Pmda Approved , Special Ptca Balloon ( Non-Compliant ) . • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Ce Approved , Special Ptca Balloon ( Non-Compliant ) . • Diameter Starting From 1.75 Mm-5.0 Mm. • Balloon Material Must Be Nylon For Controlled Compliance. • Quote Both Monorail ( Rapid Exchange ) Or Otw Balloons. • Dcgi Approved
Basic Detail
Tender No 18/17-11-2022
Bidding Type Tender
Location
City Udaipur
State Rajasthan
Key Dates
Publish Date 24 Dec 2022
Submission Date 27 Dec 2022
Open Date 28 Dec 2022
Finance
Tender Value 10 Crore
Tender Fee 1000
EMD 20 Lakhs
Exemption Not Available
Document List
445308f3-888c-4e71-9da0-d63d0bedd534.html
BOQ_543113.xls
cardiologytender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 24, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 20, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 23, 2022
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 23, 2022
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 23, 2022
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 23, 2022
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 27, 2022
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 27, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 28, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

445308f3-888c-4e71-9da0-d63d0bedd534.html

xls

BOQ_543113.xls

pdf

cardiologytender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders