Tender For Area Lighting Of Rehabilitation Building Of Ambedkar Stadium
Tender Value
2.86 Lakhs
Estimated cost
Bid Submission
26 Nov 2022
0 days left
EMD
7200
Bank guarantee accepted
Document Fee
610
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Area Lighting Of Rehabilitation Building Of Ambedkar Stadium
BOQ
| Sl. No. | Item Description |
| 1 | Supply and Installation of minimast and bracket light |
| 2 | 90.15.1.2 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter.155 mm bottom diameter thickness 3mm base plate dimensions of 250x250x16 mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos fixed in existing RCC foundation adn junction box etc, complet 9 Meters |
| 3 | 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 4 | 90.12.1.3 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). |
| 5 | 90.12.7.3 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. |
| 6 | 90.16.1.10 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG) |
| 7 | 9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 8 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 9 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 10 | od230694/2022_2023 : Supply and installationof 20 A, 230 V, DIN type fuse base |
| 11 | od230695/2022_2023 : Supply and installation of 32 A,415 V , 2 way neutral link mounted on DMC/SMC base |
| 12 | od230696/2022_2023 : Supply and installation of 32 A fuse holder for BS type blade fuses . |
| 13 | od230697/2022_2023 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828- 1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required<br>Single dial timer unit analog type |
| 14 | od230698/2022_2023 : Supply and installation of the following accessories suitable for 50Hz,AC supply conforming to IS 8828-1995 /IEC 60898 of the following current ratings in the existing enclosure and giving connections as required<br>2 pole32 A contactor |
| 15 | 90.15.4.9 : Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea withpower factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 16 | 90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea withpower factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 17 | 5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 18 | od232062/2022_2023 : SUPPLY AND INSTALLATION OF 3 WAY SQUARE TYPE JUNCTION BOX |
| 19 | od232416/2022_2023 : Supply and fixing 6 A strip connector |
| 20 | od232467/2022_2023 : Supply and installation of brackets of 1.5 meter length and made up of 25mm diameter GI pipe of suitable shape with suitable clamps,bolts and nuts for fixing and necessary accessories |
| 21 | 2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door |
| 22 | Civil works |
| 23 | 14.9 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. |
AI Tender Summary
Tender Timeline
Nov 19, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 29, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender