Defence Government Departments Closing in 0 days TDR #34872408

Tender For Providing Sewer Network, Constructing, Erecting And Commissioning Of Intermediate Sewage Pumping Stations, Lifting Stations And Design Constructions Of Sewage Treatment Plant Of 2 Mld Capacity Based On Sbr Technology And Tertiary Treatment

Issued by Government Departments · wellington, Tamil Nadu
Tender Value
25.80 Crore
Estimated cost
Bid Submission
25 Nov 2022
0 days left
EMD
25.80 Lakhs
Bank guarantee accepted
Document Fee
26000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
wellington → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Providing Sewer Network, Constructing, Erecting And Commissioning Of Intermediate Sewage Pumping Stations, Lifting Stations And Design Constructions Of Sewage Treatment Plant Of 2 Mld Capacity Based On Sbr Technology And Tertiary Treatment Plant Of 2

BOQ

Name of Work: Providing Sewer network, Constructing, Erecting and Commissioning of intermediate Sewage Pumping Stations, Lifting Stations and design constructions of sewage treatment plant of 2 MLD capacity based on SBR technology and tertiary treatment plant of 2 MLD capacity based on fibre disc filtration technology forWellington Cantonment Board, Wellington, Tamil Nadu
Sl. No. Item Description
1PART A - (1) Providing Laying andCommissioning of Sewer Collection Network including house sewer connection, Nullah, roads railway crossing using Trenchless Technology and Road Restoration in Cantonment Board
2Earth Work Excavation
3Earth work excavation for foundation & depositing on bank with an initial lead of 10 m & lift of 2 m for depths in hard stiff clay, stiff black cotton, hard red earth mixed with small sized boulders & hard gravely soil including dewatering of water as and when required, barricading with safety lamps etc all complete as per standard specification as directed by the Departmental Engineer.
4a) For 0 to 2 m depth
5Earth work excavation for foundation & depositing on bank with an initial lead of 10 m & lift of 2 m for depths in soft disintegrated Rock when required, barricading with safety lamps etc all complete as per standard specification as directed by the Departmental Engineer.
6For 2 to 3 m depth
7For 3 to 4 m depth
8Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in medium rock and dense medium rock not required blasting as directed by Departmental engineer.
9For 4 to 5 m depth
10For 5 to 6 m depth
11Shoring & strutting the sides of trench when depth of excavation exceeds 2 m in loose soil including cost of labour charges for installation & removal of planks & scantlings etc or using steel sheet plate complete & as directed by the Engineer-in-Charge.
12a) For 2 to 3 m Depth
13b) For 3 to 4 m Depth
14Refilling the trenches with suitable excavated earth available along the alignment after the pipes & specials are laid, jointed & tested in layers & watering, ramming & consolidation directed by the Engineer-in-Charge.
15Dismantling of existing CC pavement and depositing of dismantled materials along roadside or at a safe location as directed by Engineer-in-Charge
16Restoration of Road along the excavated and refilled portion of sewer pipeline trenches with gravel filling for 20 mm thk., Cement contrete of trap/granite/quartzite/gneiss metal for PCC work including normal dewatering, compaction, finishing and curing. Etc. complete
17Providing and Laying sand bedding in pipe trenches as per the direction of Engineer in charge.
18MATERIALS
19Supply of DI (CL) pipes of class K7 or K9 as per IS 8329/2000 with sulphate resistance cement with inner lining of high alumina cement as per IS:783 with epoxy coating outside of the spigot portion and poly solution coating inside the socket portion, lowering into trenches, laying to proper grade and alignment, cutting the pipes true to axis & jointing the pipes & specials with rubber rings including cost of lubricant, testing the pipe to the required pressure including barricading, provision of danger lights, arranging for watch & ward etc., complete as per specifications at different depths.
20A) 150 mm dia. pipes
21a) For 0 to 2 m depth
22b) For 2 to 4 m depth
23B) 200 mm dia. pipes
24a) For 0 to 2 m depth
25b) For 2 to 3 m depth
26b) For 3 to 3.5 m depth
27C) 250 mm dia. pipes
28a) For 0 to 2 m depth
29b) For 2 to 3 m depth
30b) For 3 to 3.5 m depth
31D) 300 mm dia. pipes
32a) For 0 to 2 m depth
33b) For 2 to 3 m depth
34b) For 3 to 3.5 m depth
35E) 350 mm dia. pipes
36a) For 0 to 2 m depth
37b) For 2 to 3 m depth
38b) For 3 to 3.5 m depth
39Supply of DI (CL) pipes of class K7 or K9 as per IS 8329/2000 with sulphate resistance cement with inner lining of high alumina cement as per IS:783 with epoxy coating outside of the spigot portion and poly solution coating inside the socket portion, lowering into trenches, laying to proper grade and alignment, cutting the pipes true to axis & jointing the pipes & specials with rubber rings including cost of lubricant, testing the pipe to the required pressure including barricading, provision of danger lights, arranging for watch & ward etc., complete as per specifications at different depths.
40A) 200 mm dia. pipes
41a) For 3 to 4 m depth
42b) For 4 to 5 m depth
43B) 250 mm dia. meter
44a) For 3 to 4 m depth
45b) For 4 to 5 m depth
46C) 300 mm dia. meter
47a) For 3 to 4 m depth
48b) For 4 to 5 m depth
49Ventilating shafts
50SEWER APPURTENANCES
51Construction of Pre-cast / cast-at-site RCC manholes of following sizes on sewer lines as per detailed drawing including supplying & fixing 600 mm dia. FRC Manholes frame & cover & encapsulated plastic steps complete as per the specifications, including earthwork excavation on all soils including rock, pumping & bailing out water where necessary, laying base cement concrete in CC 1:3:6, RCC 1:2:4 structure, plastering internal and external with 12mm thick cement plaster in CM 1:3, benching concrete in CC 1:2:4 including refilling of trenches, barricading, provision of danger lights, watch & ward & depositing surplus earth at places directed by the Engineer-in-Charge etc all complete as per standard drawing.
52Type I - 750 x 1200 mm
53a) Less than 0.9 m
54Type II - 900 x 1200 mm
550.90 to 1.0
561 to 1.5
571.5-2.0m
582.0-2.5m
59Construction of circular Precast or cast-at-site RCC manhole clear internal 1,500 mm dia.., including earthwork excavation in all type of soils, rock, bailing of water, RCC 1:2:4 structure, up to 2.5m depth and above over a bed of cement concrete in 1:3:6, internal plastering in CM 1.3 20 mm thick and external plastering in cement mortar 1:5, 12mm thick, and finished smooth with a floating coat of neat cement, PCC 1:2:4 for benching, channelling, including, providing & fixing 600mm circular FRC frame & cover, extra heavy duty, PVC encapsulated steps, refilling with excavated earth, etc complete, all as specified & directed by the Engineer-in-Charge
60Type III - 1500 mm diameter
61a) 2.5 to 3.0 m depth
62b) 3.0 to 3.5 m depth
63c) 3.5 to 4 m depth
64d) 4.0 to 4.5 m depth
65e) 4.5 to 5 m depth
66f) 5.0 to 5.5 m depth
67g) 5.5 to 6.0 m depth
68Construction of drops excluding manholes at various depths per drawing forpipes & specials incl. connections, earthwork excavation, concreting & refilling sides of foundation with excavated earth etc., complete.
69a) up to 1m depth
70b) up to 2m depth
71c) up to 3m depth
72d) up to 4m depth
73e) up to 5m depth
74F) up to 6m depth
75HOUSE SEWER CONNECTIONS
76Earth work excavation for foundation & depositing on bank with an initial lead of 10 m & lift of 2 m for depths in hard stiff clay, stiff black cotton, hard red earth mixed with small sized boulders & hard gravely soil including dewatering of water as and when required, barricading with safety lamps etc all complete as per standard specification as directed by the Departmental Engineer.
77Supplying & Laying the following size of DI pipes & lowering into trenches, laying to proper grade (60%), Alignment, Joining the pipes & specials with neat cement & hemp yarn/tarred yarn & caulking both dry & wet condition, testing the lines as directed by the departmental engineer including barricading, provision of danger lights, arranging for watch & ward etc., compete as per specifications at different depths. (IS 651:1980) and as directed by Engineer in-charge.
78100 mm dia.
79Refilling the trenches with suitable excavated earth available along the alignment after the pipes & specials are laid, jointed & tested in layers & watering, ramming & consolidation directed by the departmental engineer.
80providing and construction additional lateral rectangular Type 1 manholes in small cross streets and tenements where Households are below adjoining Road Level including provision of rider main connecting the shallow manholes for interconnection to the primary lateral sewers downstream at a suitable invert-matching cross-section. However this item excludescost of any additional pumping from household septic tanks that are in households located below road level. Provision to be as directed by Dept. Engineer and is to be field operated upon obtaining necessary approval from competent authorities.
81NH / SH / Major Rd Crossings
82Manufacture and supply of following size of MS piperequired wall thickness with 406 micron thick internal and external food grade epoxy coating(as per IS7323) duly rolling the plate to the convenient length, welding the joints.The rate includes the cost of raw materials, labour tools and plants, transportation etc
83MS Casing pipe of 610 mm diameter and 12.5 mm thickness for 250 mm dia. up to 350-mm sewer main crossing (gravity and pumping)
84MS Casing pipe of 355.6 mm diameter and 8 mm thickness for up to 200 mm gravity main crossing
85Laying of following Pipe by pushingby trenchless - pushing and jacking method. This includes construction of suitable size of driving pit, receiving pit and construction of RCC thrust wall / bed including earthwork excavation in all type of soil including SDR, hard rock and other civil works including shoring, strutting and shuttering complete and lowering, the following size of MS encasing pipe into driving pit by using contractors crane machineries and jointing MS pipes by electric welding laying the encasing pipe across the railway line / National Highways / State Highways road / Canal crossing etc., by pushing / jacking method (trenchless technology method) using contractor\"s machineries such as cranes, jacks, jacking materials, generator, welding machineries, comprising jack hammer and other equipments etc., grouting the annular space between the casing pipe andexcavated hole, under
86traffic condition in all type of soil including SDR, Hard rock without interfering and causing any hindrance to the movement of trains/buses/lorries/or any other vehicle without any disturbances to the railway/road/canal formation etc., including bailing/pumping of water wherever necessary without affecting any installation like water supply pipe line/ telephone cable, electric cable etc., passing nearby area and scooping the earth inside the pipes and pit and depositing the surplus earth in a convenient place and levelling the site after completion of entire work as directed by site engineers. The rate includes the cost of driving pit, thrust bed/wall and receiving pit to the depth of 0m to 3m and excluding the cost of MS pipes etc., complete.
87Drilling of 600mm diameter MS casing pipe
88Drilling of 350mm diameter MS casing pipe
89Supply of DI (CL) pipes of class K7 or K9 as per IS 8329/2000 with sulphate resistance cement with inner lining of high alumina cement as per IS:783 with epoxy coating outside of the spigot portion and poly solution coating inside the socket portion, lowering into trenches, laying to proper grade and alignment, cutting the pipes true to axis & jointing the pipes & specials with rubber rings including cost of lubricant, testing the pipe to the required pressure including barricading, provision of danger lights, arranging for watch & ward etc., complete as per specifications at different depths.
90250 to 350 mm dia.. DI
91200 mm dia. DI
92Canal / Nullah Crossings
93Manufacture and supply of following size of MS piperequired wall thickness with 406 micron thick internal and external food grade epoxy coating(as per IS7323) duly rolling the plate to the convenient length, welding the joints.The rate includes the cost of raw materials, labour tools and plants, transportation etc
94MS Casing pipe of 610 mm diameter and 12.5 mm thickness for 250 mm dia. up to 350-mm sewer main crossing (gravity and pumping)
95MS Casing pipe of 355.6 mm diameter and 8 mm thickness for up to 200 mm gravity main crossing
96Laying of following Pipe by pushingby trenchless - pushing and jacking method. This includes construction of suitable size of driving pit, receiving pit and construction of RCC thrust wall / bed including earthwork excavation in all type of soil including SDR, hard rock and other civil works including shoring, strutting and shuttering complete and lowering, the following size of MS encasing pipe into driving pit by using contractors crane machineries and jointing MS pipes by electric welding laying the encasing pipe across the railway line / National Highways / State Highways road / Canal crossing etc., by pushing / jacking method (trenchless technology method) using contractor\"s machineries such as cranes, jacks, jacking materials, generator, welding machineries, comprising jack hammer and other equipments etc., grouting the annular space between the casing pipe andexcavated hole, under
97traffic condition in all type of soil including SDR, Hard rock without interfering and causing any hindrance to the movement of trains/buses/lorries/or any other vehicle without any disturbances to the railway/road/canal formation etc., including bailing/pumping of water wherever necessary without affecting any installation like water supply pipe line/ telephone cable, electric cable etc., passing nearby area and scooping the earth inside the pipes and pit and depositing the surplus earth in a convenient place and levelling the site after completion of entire work as directed by site engineers. The rate includes the cost of driving pit, thrust bed/wall and receiving pit to the depth of 0m to 3m and excluding the cost of MS pipes etc., complete.
98Drilling of 600mm diameter MS casing pipe
99Drilling of 350mm diameter MS casing pipe
100Supply of DI (CL) pipes of class K7 or K9 as per IS 8329/2000 with sulphate resistance cement with inner lining of high alumina cement as per IS:783 with epoxy coating outside of the spigot portion and poly solution coating inside the socket portion, lowering into trenches, laying to proper grade and alignment, cutting the pipes true to axis & jointing the pipes & specials with rubber rings including cost of lubricant, testing the pipe to the required pressure including barricading, provision of danger lights, arranging for watch & ward etc., complete as per specifications at different depths.
101250 to 350 mm dia.. DI
102200 mm dia. DI
103Railway Crossing
104Manufacture and supply of following size of MS piperequired wall thickness with 406 micron thick internal and external food grade epoxy coating(as per IS7323) duly rolling the plate to the convenient length, welding the joints.The rate includes the cost of raw materials, labour tools and plants, transportation etc
105MS Casing pipe of 610 mm diameter and 12.5 mm thickness for 250 mm dia. up to 350-mm sewer main crossing (gravity and pumping)
106MS Casing pipe of 355.6 mm diameter and 8 mm thickness for up to 200 mm gravity main crossing
107Laying of following Pipe by pushingby trenchless - pushing and jacking method. This includes construction of suitable size of driving pit, receiving pit and construction of RCC thrust wall / bed including earthwork excavation in all type of soil including SDR, hard rock and other civil works including shoring, strutting and shuttering complete and lowering, the following size of MS encasing pipe into driving pit by using contractors crane machineries and jointing MS pipes by electric welding laying the encasing pipe across the railway line / National Highways / State Highways road / Canal crossing etc., by pushing / jacking method (trenchless technology method) using contractor\"s machineries such as cranes, jacks, jacking materials, generator, welding machineries, comprising jack hammer and other equipments etc., grouting the annular space between the casing pipe andexcavated hole, under traffic condition in all type of soil including SDR, Hard rock without interfering and causing any hindrance to the movement of trains/buses/lorries/or any other vehicle without any disturbances to the railway/road/canal formation etc., including bailing/pumping of water wherever necessary without affecting any installation like water supply pipe line/ telephone cable, electric cable etc., passing nearby area and scooping the earth inside the pipes and pit and depositing the surplus earth in a convenient place and levelling the site after completion of entire work as directed by site engineers. The rate includes the cost of driving pit, thrust bed/wall and receiving pit to the depth of 0m to 3m and excluding the cost of MS pipes etc., complete.
108Drilling of 600mm diameter MS casing pipe
109Drilling of 350mm diameter MS casing pipe
110Supply of DI (CL) pipes of class K7 or K9 as per IS 8329/2000 with sulphate resistance cement with inner lining of high alumina cement as per IS:783 with epoxy coating outside of the spigot portion and poly solution coating inside the socket portion, lowering into trenches, laying to proper grade and alignment, cutting the pipes true to axis & jointing the pipes & specials with rubber rings including cost of lubricant, testing the pipe to the required pressure including barricading, provision of danger lights, arranging for watch & ward etc., complete as per specifications at different depths.
111250 to 350 mm dia.. DI
112200 mm dia. DI
113Restoration of the Refilled UGSS Portion of BT Road
114Providing plain Cement Concrete 1:4:8 mix using 40mm gauge hard broken granite (HBG) metal for pavement including cost and conveyance of material to site including cost and supply and provision of construction and expansion joints along alignment and cross section and fixing in position including labour charges for laying concrete, watering, consolidation, finishing and hire charges for all tools and plant etc complete as per MoRTH Specification.
115Providing Plain cement Concrete 1:2:4 mix using 20mm gauge hard broken granite (HBG) metal for pavement including cost and conveyance of material to site including cost and supply and provision of construction and expansion joints along alignment and cross section and fixing in position including labour charges for laying concrete, watering, consolidation, finishing and hire charges for all tools and plant etc complete as per MoRTH Specification.
116Providing B.M. 50mm consolidated thick incl. Tack cost using 4kg Over WBM Surface/ Using 3 kg Over BT Surface/ using 0.42m3 of 26.5mm to 11.20mm graded metal of IRC Size and 0.10cum of 11.2 to 2.80mm and 0.18 m3 of 2.8mm and below (it should satisfy the aggregate grading as per graduation in table 500-5) for 10sq.m with 38kg of bitumen for premising including cost of bitumen including conveyance of bitumen to CMP site and also to work site handling charges at both ends for the same including a labour for loading bitumen in bitumen tank and metal to feeder unit labour for attending to paver site heating the bitumen and metal to required temperature and mixing the metal and bitumen to required temperature in the central hot mix plant 20-30 ton capacity
117Conveying the mix by tipper trucks to paver site spreading the mix in required temperature for uniform thickness 50mm with Mechanic paver to the specified grades and cross section and consolidated by power roller to get the required density including higher charges and fuel charges for CMP 20-30 ton Capacity, paver finisher, tipper trucks, Power Roller, Bitumen Boiler and all other T&P required and including all other incidental charges etc. Complete as per specification.
118Providing and laying semi dense bituminous concrete 25mm compacted thickness using 0.10 cum of 11.2 mm IRC HBG metal 0.16 cum of 6.7 mm IRC HBG metal 0.11 cum of 2.8 mm and below with 24 Kg of bitumen per 10 sqm. For premixing including cost and conveyance of all materials to site and stocking them on road side to departmental metric gauge for per measurements, heating the bitumen in bitumen boiler, heating the aggregates and mixing them with bitumen in mini hot mix plant, spreading the mix in the required temperature for uniform thickness of 25 mm to the specified grade and cross sections and compaction by 8-10 power roller etc. Includinghire charges and fuel charges for power roller, bitumen boiler, mini hot mix plant and all other tools and plant employed etc. Complete as per clause 511 of MORTH specification.
119Restoration of Foot Path
120providing Plain Cement concrete 1:4:8 mix using 40mm gauge hard broken granite (HBG) metal for pavement including cost and conveyance of materials to site including cost and supply and provision of construction and expansion joints along alignment and cross section and fixing in position including labour charges for laying concrete, watering, consolidation, finishing and hire charges for all tools and plants etc complete as per MORTH specification.
121MES SSR 2010 rate item 04026 for channels / drains PCC 1:4:8 w/40mm
122Providing Plain Cement Concrete 1:2:4 mix using 20 mm gauge hard broken granite (HBG) metal for pavement including cost and conveyance of materials to site including cost and supply and provision of construction and expansion joints along alignment and cross section and fixing in position including labour charges for laying concrete, watering, consolidation, finishing and hire charges for all tools and plants etc complete as per MORTH specification.
123Brickwork w/ sub-class B bricks straight or curved on plan exc. 6m mean radius built in CM 1:6
124Form - work to sides of concrete surfaces (PCC1:2:4 work section)
125Rendering with CM 1:6, 15 mm thick
126Road Restoration of Concrete Road
127Dismantling of Existing CC pavement for the section outside the UG trench limit (This section already accounted for in main Estimate) for an average road width of 2.5m total and total dismantling thickness of 25cm average, up to sub base level including all costs for removal of material, tolls, plant etc. Complete as per standard specifications.
128providing Plain Cement concrete 1:4:8 mix using 40mm gauge hard broken granite (HBG) metal for pavement including cost and conveyance of materials to site including cost and supply and provision of construction and expansion joints along alignment and cross section and fixing in position including labour charges for laying concrete, watering, consolidation, finishing and hire charges for all tools and plants etc complete as per MORTH specification.
129Providing Plain Cement Concrete 1:2:4 mix using 20 mm gauge hard broken granite (HBG) metal for pavement including cost and conveyance of materials to site including cost and supply and provision of construction and expansion joints along alignment and cross section and fixing in position including labour charges for laying concrete, watering, consolidation, finishing and hire charges for all tools and plants etc complete as per MORTH specification.
130Road Restoration along National Highway Stretch
131Cleaning Jungle including uprooting of rank, vegetations, grass, bush, shrub, wood trees and samplings of girth up to 30 cms measured at a height of up to 20 above ground level and removal of rubbish up to a distance of 50m outside the periphery of area cleared including cost of all machinery, labour, tools, plant, power, water etc, complete
132Forming Embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick, watering ramming/rolling and finishing to required size, shape, etc. N exc. 1.5m high from base as per MORT& H specifications for all kinds of soil etc complete
133Supplying and laying water bound macadam sub base (GSB) with broken boulders, interstices filled and binding material, earth etc including screening, sorting and spreading to template and consolidation with light power road roller etc complete including cost of all machinery, tolls, plant, labor, material etc as per MORT&H specifications
134Providing, laying, spreading and compacting stone aggregate of specified sizes to WBM specifications including spreading in uniform thickness, hand picking, rolling with 3 rolled road/ vibratory roller 8-10 tonne in stages to proper grade and camber, applying and booming requisite type of screening/binding material to fill up interstices of coarse aggregate watering and compacting to the required density. wooden or steel rammers and rolling over 3rd and top most layer with power roller of minimum 8 tonnes and dressing up, in embankment for roads, flood banks, marginal banks and guide banks etc lead up to 50 m and lift up to 1.5 m as per table 400-7 of MORT&H specifications for all kinds of soil.
135Hand broken - Grade-I (90-45mm) - for 100 mm thick
136Hand broken - Grade-II (63-45mm) -for 75 mm thick
137Hand broken - Grade-III (53-22.4mm) -for 75 mm thick
138Providing and applying tack coat using hot straight run bitumen of grade 80/100 including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per surface as per MORT&H specifications on WBM new surface @ 10 kg/10 sqm
139Providing 2 cm premix carpet surfacing with 1.8 cum and 0.9 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively including consolidation with road roller of 6-9 tonne capacity etc. complete (tack coat to be paid separately) with paving asphalt 80/100 heated and then mixed with solvent at the rate of 70 gms per kg of asphalt including cost for all items such as machinery, tools, plant, etc complete as per MORT&H specification.
140Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade 80/100 and binding surface with 0.90 cum of stone aggregate of 6.7 mm size (passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 Sqm. of road surface including rolling and finishing with power road roller and including cost for all items such as machinery, tools, plant, etc complete as per MORT&H Specification.
141Planting road surface marking with adequate number of coats to give uniform finish with ready mixed road marking paint confirming to IS:164, on bituminous surface in white/ yellow shade including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. New work (two or more coats) including cost for all items such as machinery, tools, plant, etc complete as per MORT&H Specification
142Civil Works of SPS -1
143SCREEN WELL (3.0 m F )
144Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
145For 0 to 2 m depth
146Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
147For 2 to 3 m depth
148For 3 to 4 m depth
149Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
150For 4 to 5 m depth
151For 5 to 6 m depth
152For 6 to 6.71 m depth
153Supplying & laying Reinforced Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
154Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
155Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm diameter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
156Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
157Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
158Transportation of earth from the site to disposal site at a minimum distance of 5 km from the site
159Providing and fixing of MS screens of dimensions as shown in drawings with MS flats of 20 x 50 mm with c/c spacing of 25 welded to angle frame of 100 x 100 x 8 mmetc all complete
160MS Rugs
161GRIT WELL (2.0 m F )
162Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
163For 0 to 2 m depth
164Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
165For 2 to 3 m depth
166For 3 to 4 m depth
167Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
168For 4 to 5 m depth
169For 5 to 6 m depth
170For 6 to 7 m depth
171For 7 to 7.81 m depth
172Supplying & laying Reinforced Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
173Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
174Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm diameter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
175Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
176Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
177Transportation of earth from the site to disposal site at a minimum distance of 5 km from the site
178MS Rugs
179WET WELL (3 m F )
180Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
181For 0 to 2 m depth
182Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
183For 2 to 3 m depth
184For 3 to 4 m depth
185Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
186For 4 to 5 m depth
187For 5 to 6 m depth
188For 6 to 7 m depth
189For 7 to 8 m depth
190For 8 to 9 m depth
191For 9 to 9.41 m depth
192Supplying & laying Reinforced Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
193Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
194Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm diameter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
195Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
196Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
197Transportation of earth from the site to disposal site at a minimum distance of 5 km from the site
198MS Rugs
199MECH WORKS OF SPS - 1 (PIPING VALVES & APPURTENANCES)
200Screen Chamber
201Supply and delivery of 200 mm, DI (CL), Class K7 per IS 8329-2000 flanged ends including specials and appurtenances
202Fabrication, supply and installation of manually cleaned CI bar screen (50 x 10 mm thick) complete with grouting and epoxy coating, weighing approx. 4.70 kg/m
203Supply and installation of CI Sluice Gate suitable for inlet sewer pipe 200 mm dia.., raised spindle, single face, wall thimble mounted, bottom closing, flanged back frame, as per IS:13349:1991 class 1 including headstock, guide collar, epoxy painted, per specifications and as directed by the Engineer-in-charge
204Supply and delivery of sewer outlet pipe connected to Grit Well, 200 mm, DI (CL) flanged, Class K7 per IS 8329-2000 including specials and appurtenances
205Grit Well & Grit Removal Pit
206Supply and installation of CI Sluice Gate suitable for inlet sewer pipe 200 mm dia.., raised spindle, single face, wall thimble mounted, bottom closing, flanged back frame, as per IS:13349:1991 class 1 including headstock, guide collar, epoxy painted, per specifications and as directed by the Engineer-in-charge
207Supply and installation of grit removal and overflow pipe, flanged DI (CL), 200 mm
208Sewer outlet pipe connected to Suction Well, 200 mm, DI (CL) flanged ends
209Suction Well
210NON-RETURN BALL VALVE: Supply and installation at site, CI Ball valve suitable for sewage service,50 mm, CI, flanged ends with support concrete pad
211NON-RETURN BALL VALVE: Supply and installation at site, CI Ball valve suitable for sewage service, 200 mm, CI, flanged ends with support concrete pad
212Supplying and Conveying CI Double Flanged Sluice Valves (PN 1.0) with cap of 80mmconfirming to IS:14846, to site, including flanged tail pieces and other specials as required, loading, unloading, transportation charges & stacking at site etc. complete per specifications and as directed by the Departmental Engineer.
213Supplying and Conveying CI Double Flanged Sluice Valves (PN 1.0) with cap of80mm confirming to IS:14846, to site, including flanged tail pieces and other specials as required, loading, unloading, transportation charges & stacking at site etc. complete per specifications and as directed by the Departmental Engineer.
214Supply and delivery of discharge pipe, 50 mm, DI (CL), PN 10 flanged pipe per IS flanged ends including appurtenances
215Supply and delivery of discharge pipe, 80 mm, DI (CL), PN 10 flanged pipe per IS flanged ends including appurtenances
216Supply and installation of 2 Ton capacity hand operated Over Head Travelling crane, for a span of 6 m, travel up to 10 m and lift of 6 m including gear type chain pulley block and geared travelling trolley complete with civil works and accessories
217Pipe Appurtenances (Specials)
21890 deg bend, DI (CL) flanged, 150-mm dia.., 3 Nos.
21990 deg bend, DI (CL) flanged, 200-mm dia.., 1 No.
220250 x 250 X 200 mm flanged Tee, DI (CL), 3 Nos.
221250 x 250 X 200 mm flanged Tee, DI (CL), 1 No.
222Blank Flanges with fasteners, DI, 200 mm, 2 Nos.
223Blank Flanges with fasteners, DI, 150 mm, 6 Nos.
224reducer 200 X 150 mm
225Pumping Main
226Supplying, conveying of DI flanged pipe PN 10 min, 100 mm diameter Class K-9 as per IS:8329-2000, including all specials, transportation charges, loading, unloading etc., complete as per standard specifications and as directed by the Engineer-in-charge
227Laying, jointing of DI pipe, 100 mm diameterincluding carting of pipes from the Departmental stores to the site of work, lowering into trenches and aligning, etc..
228Providing Sand Bedding for the pipe line trenches including watering and consolidation complete with an initial lead of 50 m etc.
229Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Departmental engineer.
230Refilling pipeline trenches and foundation with selected available earth from trench excavation and foundation including watering, consolidation in layers of 15 cm, thickness including disposing off the surplus earth with a lead of 200 m.
231ELECTRICAL WORKS OF SPS - 1
232Pumping Equipment
233Supply and installation of SUBMERSIBLE SEWAGE PUMPS: Non-clog type, single stage - single suction - CF8M impeller - in standard construction fitted with double mechanical seal for gland sealing with integrated oil chamber and sensor, complete with duck foot bend, lifting lug and pedestal coupling assembly as per reference TWAD Spec & relevant IS complete.
23410 cum/hr@ 19 m TDH - 1 Operating + 1 Standby
23530 cum/hr@ 19 m TDH - 1 Operating + 1 Standby
236Supply and installation of MS Galvanized Guide Pipe with wall mount plate and fasteners, suitable lengths
237Supply and installation of MS Galvanized lifting chain, standard length for each pump installed
238SUBMERSIBLE GRIT REMOVAL PUMP - Non-clog type; single stage - single suction - CF8M impeller with SS grit cutter manifold - in standard construction fitted with oil-lubricated double mechanical seal for gland sealing with integrated oil chamber/sensor and flexible flanged discharge hose, 45 cum./hr, 10m H, 7.5 HP
239Electrical Equipment
240Supply and Installation of TNEB METERING BOARD complete suitable for 3-phase 25 KW load with following provisions (included):
241a) 100 A fuse cut-out 3 nos.
242b) 124 A TPN SFU
243c) 1 no. 63A Neutral link
244d) 1 no. 4-way earth plate with bolts-nuts
245e) 0-400 V voltmeter and 3 nos. indicator lamps for 3-phase in suitable MS Box with all interconnection wire and space for TNEB meter
246Above items shall be mounted on min. 6-mm thick Hylam Sheet and with angle supports on wall at a suitable location as directed by Dept Engineer
247Supply and installation of LT Panel complete with Incomer and Outgoing Feeders complete with MCCB, selector switch, energy meter, fuses and all requisite accessories (Manufacturer Rate)
248Incomer - Two Nos
249125A 4P 35KA MCCB
250C.Ts 200/5A
251Ammeter, Selector Switch
252Voltmeter, Selector Switch
253KWH Meter
254PF Meter
255Indication Lamp
256Control Fuses
257Castle Inter Lock
258OUT GOING FEEDERS
25963A,TPN,50KA,MCCB
260C.Ts 40/5A
261Standard Metering Panel with Ammeter, Voltmeter and indicators
26232A,TPN,50KA,MCCB
263C.Ts 40/5A
26432A TPN MCB
26510A DP MCB
266Shell
267Busbar
268Insulators Sleeve
269Wire coils
270Erection
271Earthing arrangements as per IE rules
272Supply and Installation of one (1) Diesel Generator complete with mounting pad, exhaust manifold, change-over and accessories
273415V / 1,500 RPM / 20 KVA (BHP-83)
274Installation Cost
275Supply and Installation of Main Control Panel for Submersible Pumps, complete with ammeter and single phase preventer, push button control and accessories (rated for 3+1 nos, 5 HP ea.)
276Vendor Rate
27763A TPN SFU With HRC fuse
278CT 40/5A
279Ammeter, Selector Switch (0-40)A
280Voltmeter Selector Switch (0-500)v
28125A Power contactor (MN25,15KVAr)
282OLR 14-23A
283Indication lamp
284Timer (0 - 30)sec
285Auxiliary contactor
286Push button
287Under voltage relay
288Thermal relay
289Level control
290Moisture control
291Single phase preventer
292Shell
293Wires & TBs
294Miscellaneous
295Installation charges
296MS Outdoor box with painted (optional only if open mounted)
297Push button
298Supply and Installation of Pump Control Panels for submersible pumps, complete with selector switch, relay, phase preventer, push button control and accessories.
299Supply and installation of one Direct-on-Line Starter suitable for One (1) Grit Removal submersible pump, rated at 1 HP, complete with accessories and mounting arrangement
300Supply and installation of one Direct-on-Line Starter suitable for one(1) general utility water supply pump, rated at 1 HP, complete with accessories and mounting arrangement for 1HP pump
301Supply and Laying of Power and Control Cables from TNEB Panel to LT Panel and onward to all components and to DG Set complete with termination
302EB,DG to L.T panel to motor, starter, power cables
3034C x 16 sq.mm Al.Arm cable.
3043C x 10 sq.mm Al.Arm cable.
3053C x 6 sq.mm Al Arm cable
3063C x 4 sq.mm Al Arm cable
307Control Cables:
3084C x 1.5 sq.mm Cu flexible cable
3097C x 1.5 sq.mm CU.Arm cable.
3103C x 4 sq.mm Al.Arm cable.
311Termination for the following cables with necessary accessories
3124C x 16 sq.mm Al.Arm cable.
3133C x10 sq.mm CU Arm cable
3143C x 6 sq.mm Al Arm cable
3154C x 1.5 sq.mm CU.Arm cable.
3167C x 1.5 sq.mm CU.Arm cable.
3173C x 4 sq.mm. Al. Arm cable.
318Supply and installation of earthing (grounding) arrangement for all electrical equipment complete with accessories.
319100mm CI pipe with funnel, clamp 3mts long
320CI cover plate
321Sand /charcoal/salt
322Masonry
323Supply of 25x3mm Cu flat (100 m approx.)
324Supply & laying of 10 SWG CU wire
325Earth pit Erection
326Supply and Installation of Indoor and Outdoor Light fittings, cables, cut-outs and fans complete with accessories and mounting
327Supply and installation of four way TPN DB\"s
3284 way TPN DB
32963A 4P MCB as incomer
33032A TPN MCB as out going
331SPN DB\"S :
3326 Way SPN Lighting DB
33332A DP MCB 30mA ELCB as incomer
3346A SPN MCB Outgoing
335Angle Iron Frame, Erection
336LIGHT FITTINGS
337Industrial type florescent lamp 2x40w(local rate)
338Decorative type florescent lamp 2x40w
339Street light fitting fluorescent 1x40w
340Bulk head fitting 100/60w
3416m tubular street light poles - GI 65 mm
342200x200x50mm MS box
34310A MCB
344Sodium vapour lamp 125w(local rate)
345Terminal block 6 way suitable for 4 sq.mm. Cable
346WIRING
347Point wiring surface / concealed for lighting points with copper wire
348Point wiring surface / concealed for 6A /16 A (1ph,3pin) switch socket
349Supply and delivery of the following safety equipment and tools
3505KG capacity dry chemical powder type fire extinguisher
351Wooden First aid box.
352Fire bucket stand with 3 round bottom bucket
353Rubber mat of 1.1KV grade of size 6mmthick
354Fire safety rules chart.( Local Rates).
355Shock treatment chart
356Supply and delivery of the following maintenance tools/equipment:
357Socket set with hi-hexagon socket made up of chromium vanadium steel with attachment for 1 1/2\"\" square drive in metal box from 8mm to 32mm consisting of 22 nos.(Local Rates).
358Adjustable wrench made up of selected carbon steel with standard pattern of size 200mm
359Double ended open jaw spanner set
360Screw driver set consisting of various sizes of(6\"\",8\"\",12\"\").(Local Rates).
361Cutting plair 12\"\".(Local Rates).
362Hacksaw frame with blade
363Supply and Fixing GI Pipe with bends etc. on angle Iron supports and providing 4 runs of 10 sqmm PVC Cu with reel insulator and 7/11 stay wire between TNEB Post and Meter Board
364Complete as directed and approved by Dept Engr after confirmation from TNEB Authorities
365Liaisoning charges and payment of service connection fee and security deposit to TNEB including development charges
366CONTROL ROOM FOR SPS -1
367Earth work excavation for foundation & depositing on bank with an initial lead of 10 m & lift of 2 m for depths in hard stiff clay, stiff black cotton, hard red earth mixed with small sized boulders & hard gravely soil, including dewatering of water etc.,
368Supplying and filling with sand for foundation and basement including watering consolidating ramming etc complete.
369Providing and laying base concrete in foundation using Plain Cement Concrete 1:4:8 including consolidation and levelling etc as per standard specifications
370Providing Form work with centering for soffits of reinforced cement concrete slab or plain surfaces including strutting up to 3m.
371Reinforced cement concrete 1:2:4 excluding form work and reinforcement for RCC works as detailed in drawings and as per standard specifications and as directed by the Departmental Engineer etc. complete
372Laying C.C. 1:2:4 for RCC sunshade work using 20mm hard broken stone jelly 80mm thick at wall end and 50mm thick at free end projecting 600mm from wall face moulded along with RC lintels excluding the cost of reinforcement including centering compacting curing etc. complete as directed by Engineer in-charge
373Reinforcement for RCC works
374Construction of brick masonry with class II bricks in CM 1:6 in foundation including curing etc all complete as per standard specifications.
375Construction of brick masonry with class II bricks in CM 1:6 in superstructure including curing etc all complete as per standard specifications.
376Inside plastering in CM 1:4, 12 mm thick including necessary scaffolding, water the surface etc all complete as per standard specification.
377Outside plastering in CM 1:4, 15 mm thick including necessary scaffolding, watering the surface etc all complete as per standard specification.
378Ceiling plastering in CM 1:3, 12 mm thick including necessary scaffolding, water the surface etc all complete as per standard specification.
379Laying cement concrete flooring of 100 mm thick with Plain Cement Concrete 1:4:10, using 40 mm HBG stone and smooth finish etc all complete as per standard specifications
380Granolithic flooring 40mm thick cement concrete 1:2:4 mix using 3-10mm chips and top surface rendered smooth with cement including thread lining etc. as per directed by Engineer in-charge
381Refilling in excavated trenches and basement using excavated earth including complete consolidation and levelling as per standard specifications
382Concrete with broken brick jelly 20mm gauge in pure slacked lime over RCC roof slab in the proportion of 32:12 1/2 no sand to be used well beaten with wooden beaters with the required depth of 80mm thick and giving required slope and thickness to roof as required etc. complete.
383Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection >0.70 and initial emittance >0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner.
384White washing the plastered walls and ceiling with best shell lime including preparation of surface and neat finishing with 2 coats etc, complying with standard specification and as directed by the Departmental Engineer etc, complete (Inside & outside)
385Colour washing the plastered walls and ceiling with approved colour over the white washed area with neat finishing of 2 coats etc, complying with standard specification and as directed by the Departmental Engineer etc, complete (Inside & outside) - same as white washing
386Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
387a) Doors
388Teakwood panelled door in double shutter with frames 100x75mm side verticals and top. A shutter shall be 40mm thick with moulded panels in 20mm thick 4 no. of iron hold fast fixed in C.C 1:2:4 using 6 to 10mm chips 3nos. Of butt hinges 125mm long including wind appliances, furniture iron fittings, one No. of iron pad lock 15cm long for locking arrangements and fixed in position etc complete.
389b) Window
390Teakwood T.W glazed swig ventilator with frame 75x60mm all-round shutter shall be 40mm thick 3 mm glass panels including 20x20 teak fillets, sash centres, brass rings iron leaf and window card applications including fixing and position etc. complete.
391PVC syntax door in single shutter with frame of size 100x75mm at side verticals on the top with locking arrangement etc. complete for toilet
392Providing and fixing in position of Rolling Shutter of size (2.5 x 3 m) including all necessary permanent fittings as per standard specifications and as directed by the Departmental Engineer etc, complete
393Supplying and fixing of MS grating with Chequered plate of 6 mm thick over the cable trench as directed by Departmental Engineer etc all complete as per standard specifications.
394Painting of panelled doors and windows with 2 coats of enamel paint including a coat of primer, including scraping, sand papering and preparation of surface including cost of brushes, with neat finishing etc all complete as per standard specifications.
395Painting of Rolling shutter with 2 coats of paint including a coat of primer, scraping, sand papering and preparation of surface including cost of brushes, with neat finishing etc all complete as per standard specifications.
396Supplying fixing 75mm dia.AC rainwater down fall pipe including cost of bends, anchors etc.
397Providing fixing MS grills for window including one coat of primer with red lead and painting etc. complete as directed.
398Provision for Rainwater harvesting arrangements as per municipal specifications
399Civil Works of SPS -2
400SCREEN WELL (3.0 m F )
401Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
402For 0 to 2 m depth
403Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
404For 2 to 3 m depth
405For 3 to 4 m depth
406Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
407For 4 to 5 m depth
408For 5 to 6 m depth
409For 6 to 6.71 m depth
410Supplying & laying Reinforced Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
411Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
412Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm dia.meter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
413Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
414Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
415Transportation of earth from the site to disposal site at a minimum distance of 5 km from the site
416Providing and fixing of MS screens of dimensions as shown in drawings with MS flats of 20 x 50 mm with c/c spacing of 25 welded to angle frame of 100 x 100 x 8 mmetc all complete
417MS Rugs
418GRIT WELL (2.0 m F )
419Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
420For 0 to 2 m depth
421Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
422For 2 to 3 m depth
423For 3 to 4 m depth
424Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
425For 4 to 5 m depth
426For 5 to 6 m depth
427For 6 to 7 m depth
428For 7 to 7.81 m depth
429Supplying & laying Reinforced Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
430Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
431Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm dia.meter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
432Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
433Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
434Transportation of earth from the site to disposal site at a minimum distance of 5 km from the site
435MS Ruges
436WET WELL (4 m F )
437Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
438For 0 to 2 m depth
439Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
440For 2 to 3 m depth
441For 3 to 4 m depth
442Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
443For 4 to 5 m depth
444For 5 to 6 m depth
445For 6 to 7 m depth
446For 7 to 8 m depth
447For 8 to 9 m depth
448For 9 to 9.41 m depth
449Supplying & laying Reinforced Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
450Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
451Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm dia.meter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
452Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
453Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
454Transportation of earth from the site to disposal site at a minimum distance of 5 km from the site
455MS Ruges
456MECH WORKS OF SPS - 2 (PIPING VALVES & APPURTENANCES)
457Screen Chamber
458Supply and delivery of 200 mm, DI (CL), Class K7 per IS 8329-2000 flanged ends including specials and appurtenances
459Fabrication, supply and installation of manually cleaned CI bar screen (50 x 10 mm thk) complete with grouting and epoxy coating, weighing approx. 4.70 kg/m
460Supply and installation of CI Sluice Gate suitable for inlet sewer pipe 200 mm dia.., raised spindle, single face, wall thimble mounted, bottom closing, flanged back frame, as per IS:13349:1991 class 1 including headstock, guide collar, epoxy painted, per specifications and as directed by the Engineer-in-charge
461Supply and delivery of sewer outlet pipe connected to Grit Well, 200 mm, DI (CL) flanged, Class K7 per IS 8329-2000 including specials and appurtenances
462Grit Well & Grit Removal Pit
463Supply and installation of CI Sluice Gate suitable for inlet sewer pipe 200 mm dia.., raised spindle, single face, wall thimble mounted, bottom closing, flanged back frame, as per IS:13349:1991 class 1 including headstock, guide collar, epoxy painted, per specifications and as directed by the Engineer-in-charge
464Supply and installation of grit removal and overflow pipe, flanged DI (CL), 200 mm
465Sewer outlet pipe connected to Suction Well, 200 mm, DI (CL) flanged ends
466Suction Well
467NON-RETURN BALL VALVE: Supply and installation at site, CI Ball valve suitable for sewage service, 80 mm, CI, flanged ends with support concrete pad
468NON-RETURN BALL VALVE: Supply and installation at site, CI Ball valve suitable for sewage service, 150 mm, CI, flanged ends with support concrete pad
469Supplying and Conveying CI Double Flanged Sluice Valves (PN 1.0) with cap of 80mm confirming to IS:14846, to site, including flanged tail pieces and other specials as required, loading, unloading, transportation charges & stacking at site etc.
470Supplying and Conveying CI Double Flanged Sluice Valves (PN 1.0) with cap of 150mm confirming to IS:14846, to site, including flanged tail pieces and other specials as required, loading, unloading, transportation charges & stacking at site etc.
471Supply and delivery of discharge pipe, 80 mm, DI (CL), PN 10 flanged pipe per IS flanged ends including appurtenances
472Supply and delivery of discharge pipe, 150 mm, DI (CL), PN 10 flanged pipe per IS flanged ends including appurtenances
473Supply and installation of 2 Ton capacity hand operated Over Head Travelling crane, for a span of 6 m, travel up to 10 m and lift of 6 m including gear type chain pulley block and geared travelling trolley complete with civil works and accessories
474Pipe Appurtenances (Specials)
47590 deg bend, DI (CL) flanged, 100-mm dia.., 3 Nos.
47690 deg bend, DI (CL) flanged, 200-mm dia.., 1 No.
477200 x 200 X 150 mm flanged Tee, DI (CL), 3 Nos.
478200 x 200 X 200 mm flanged Tee, DI (CL), 1 No.
479Blank Flanges with fasteners, DI, 200 mm, 2 Nos.
480Blank Flanges with fasteners, DI, 100 mm, 6 Nos.
481Pumping Main
482Supplying, conveying of DI flanged pipe PN 10 min, 150 mm dia.meter Class K-9 as per IS:8329-2000, including all specials, transportation charges, loading, unloading etc., complete as per standard specifications and as directed by the Engineer-in-charge
483Laying, jointing of DI pipe, 150 mm dia.meter class K9 including carting of pipes from the Departmental stores to the site of work, lowering into trenches and aligning, etc..
484Providing Sand Bedding for the pipe line trenches including watering and consolidation complete with an initial lead of 50 m etc.
485Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Departmental engineer.
486Refilling pipeline trenches and foundation with selected available earth from trench excavation and foundation including watering, consolidation in layers of 15 cm, thickness including disposing off the surplus earth with a lead of 200 m.
487ELECTRICAL WORKS OF SPS - 2
488Pumping Equipment
489Supply and installation of SUBMERSIBLE SEWAGE PUMPS: Non-clog type, single stage - single suction - CF8M impeller - in standard construction fitted with double mechanical seal for gland sealing with integrated oil chamber and sensor, complete with duck foot bend, lifting lug and pedestal coupling assembly as per reference TWAD Spec & relevant IS complete.
49027 cum/hr@ 22 m TDH - 1 Operating + 1 Standby
49181 cum/hr@ 22 m TDH - 1 Operating + 1 Standby
492Supply and installation of MS Galvanized Guide Pipe with wall mount plate and fasteners, suitable lengths
493Supply and installation of MS Galvanized lifting chain, standard length for each pump installed
494SUBMERSIBLE GRIT REMOVAL PUMP - Non-clog type; single stage - single suction - CF8M impeller with SS grit cutter manifold - in standard construction fitted with oil-lubricated double mechanical seal for gland sealing with integrated oil chamber/sensor and flexible flanged discharge hose, 45 cu.m./hr, 10m H, 7.5 HP
495Electrical Equipment
496Supply and Installation of TNEB METERING BOARD complete suitable for 3-phase 25 KW load with following provisions (included):
497a) 100 A fuse cut-out 3 nos.
498b) 124 A TPN SFU
499c) 1 no. 63A Neutral link
500d) 1 no. 4-way earth plate with bolts-nuts
501e) 0-400 V voltmeter and 3 nos. indicator lamps for 3-phase in suitable MS Box with all interconnection wire and space for TNEB meter
502Above items shall be mounted on min. 6-mm thick Hylam Sheet and with angle supports on wall at a suitable location as directed by Dept Engr
503Supply and installation of LT Panel complete with Incomer and Outgoing Feeders complete with MCCB, selector switch, energy meter, fuses and all requisite accessories (Manufacturer Rate)
504Incomer - Two Nos
505125A 4P 35KA MCCB
506C.Ts 200/5A
507Ammeter, Selector Switch
508Voltmeter, Selector Switch
509KWH Meter
510PFMeter
511Indication Lamp
512Control Fuses
513Castle Inter Lock
514OUT GOING FEEDERS
51563A,TPN,50KA,MCCB
516C.Ts 40/5A
517Standard Metering Panel with Ammeter, Voltmeter and indicators
51832A,TPN,50KA,MCCB
519C.Ts 40/5A
52032A TPN MCB
52110A DP MCB
522Shell
523Busbar
524Insulators Sleeve
525Wire coils
526Erection
527Earthing arrangements as per IE rules
528Supply and Installation of one (1) Diesel Generator complete with mounting pad, exhaust manifold, change-over and accessories
529415V / 1,500 RPM / 20 KVA (BHP-83)
530Installation Cost
531Supply and Installation of Main Control Panel for Submersible Pumps, complete with ammeter and single phase preventer, push button control and accessories (rated for 3+1 nos, 5 HP ea.)
532Vendor Rate
53363A TPN SFU With HRC fuse
534CT 40/5A
535Ammeter, Selector Switch (0-40)A
536Voltmeter Selector Switch (0-500)v
53725A Power contactor (MN25,15KVAr)
538OLR 14-23A
539Indication lamp
540Timer (0 - 30)sec
541Auxiliary contactor
542Push button
543Under voltage relay
544Thermal relay
545Level control
546Moisture control
547Single phase preventer
548Shell
549Wires & TBs
550Miscellaneous
551Installation charges
552MS Outdoor box with painted (optional only if open mounted)
553Push button
554Supply and Installation of Pump Control Panels for submersible pumps, complete with selector switch, relay, phase preventer, push button control and accessories.
555Supply and installation of one Direct-on-Line Starter suitable for One (1) Grit Removal submersible pump, rated at 1 HP, complete with accessories and mounting arrangement
556Supply and installation of one Direct-on-Line Starter suitable for one(1) general utility water supply pump, rated at 1 HP, complete with accessories and mounting arrangement for 1HP pump
557Supply and Laying of Power and Control Cables from TNEB Panel to LT Panel and onward to all components and to DG Set complete with termination
558EB,DG to L.T panel to motor, starter, power cables
5594C x 16 sq.mm Al.Arm cable.
5603C x 10 sq.mm Al.Arm cable.
5613C x 6 sq.mm Al Arm cable
5623C x 4 sq.mm Al Arm cable
563Control Cables:
5644C x 1.5 sq.mm Cu flexible cable
5657C x 1.5 sq.mm CU.Arm cable.
5663C x 4 sq.mm Al.Arm cable.
567Termination for the following cables with necessary accessories
5684C x 16 sq.mm Al.Arm cable.
5693C x10 sq.mm CU Arm cable
5703C x 6 sq.mm Al Arm cable
5714C x 1.5 sq.mm CU.Arm cable.
5727C x 1.5 sq.mm CU.Arm cable.
5733C x 4 sq.mm. Al. Arm cable.
574Supply and installation of earthing (grounding) arrangement for all electrical equipment complete with accessories.
575100mm CI pipe with funnel, clamp 3mts long
576CI cover plate
577Sand /charcoal/salt
578Masonry
579Supply of 25x3mm Cu flat (100 m approx.)
580Supply & laying of 10 SWG CU wire
581Earth pit Erection
582Supply and Installation of Indoor and Outdoor Light fittings, cables, cut-outs and fans complete with accessories and mounting
583Supply and installation of four way TPN DB\"s
5844 way TPN DB
58563A 4P MCB as incomer
58632A TPN MCB as out going
587SPN DB\"S :
5886 Way SPN Lighting DB
58932A DP MCB 30mA ELCB as incomer
5906A SPN MCB Outgoing
591Angle Iron Frame, Erection
592LIGHT FITTINGS
593Industrial type florescent lamp 2x40w(local rate)
594Decorative type florescent lamp 2x40w
595Street light fitting fluorescent 1x40w
596Bulk head fitting 100/60w
5976m tubular street light poles - GI 65 mm
598200x200x50mm MS box
59910A MCB
600Sodium vapour lamp 125w(local rate)
601Terminal block 6 way suitable for 4 sq.mm. Cable
602WIRING
603Point wiring surface / concealed for lighting points with copper wire
604Point wiring surface / concealed for 6A /16 A (1ph,3pin) switch socket
605Supply and delivery of the following safety equipment and tools
6065KG capacity dry chemical powder type fire extinguisher
607Wooden First aid box.
608Fire bucket stand with 3 round bottom bucket
609Rubber mat of 1.1KV grade of size 6mmthick
610Fire safety rules chart.( Local Rates).
611Shock treatment chart
612Supply and delivery of the following maintenance tools/equipment:
613Socket set with hi-hexagon socket made up of chromium vanadium steel with attachment for 1 1/2\"\" square drive in metal box from 8mm to 32mm consisting of 22 nos.(Local Rates).
614Adjustable wrench made up of selected carbon steel with standard pattern of size 200mm
615Double ended open jaw spanner set
616Screw driver set consisting of various sizes of(6\"\",8\"\",12\"\").(Local Rates).
617Cutting plair 12\"\".(Local Rates).
618Hacksaw frame with blade
619Supply and Fixing GI Pipe with bends etc. on angle Iron supports and providing 4 runs of 10 sqmm PVC Cu with reel insulator and 7/11 stay wire between TNEB Post and Meter Board
620Complete as directed and approved by Dept Engr after confirmation from TNEB Authorities
621Liaisoning charges and payment of service connection fee and security deposit to TNEB including development charges
622CONTROL ROOM FOR SPS -2
623Earth work excavation for foundation & depositing on bank with an initial lead of 10 m & lift of 2 m for depths in hard stiff clay, stiff black cotton, hard red earth mixed with small sized boulders & hard gravely soil, including dewatering of water etc.,
624Supplying and filling with sand for foundation and basement including watering consolidating ramming etc complete.
625Providing and laying base concrete in foundation using Plain Cement Concrete 1:4:8 including consolidation and levelling etc as per standard specifications
626Providing Form work with centering for soffits of reinforced cement concrete slab or plain surfaces including strutting up to 3m.
627Reinforced cement concrete 1:2:4 excluding form work and reinforcement for RCC works as detailed in drawings and as per standard specifications and as directed by the Departmental Engineer etc. complete
628Laying C.C. 1:2:4 for RCC sunshade work using 20mm hard broken stone jelly 80mm thick at wall end and 50mm thick at free end projecting 600mm from wall face moulded along with RC lintels excluding the cost of reinforcement including centering compacting curing etc. complete as directed by Engineer in-charge
629Reinforcement for RCC works
630Construction of brick masonry with class II bricks in CM 1:6 in foundation including curing etc all complete as per standard specifications.
631Construction of brick masonry with class II bricks in CM 1:6 in superstructure including curing etc all complete as per standard specifications.
632Inside plastering in CM 1:4, 12 mm thick including necessary scaffolding, water the surface etc all complete as per standard specification.
633Outside plastering in CM 1:4, 15 mm thick including necessary scaffolding, watering the surface etc all complete as per standard specification.
634Ceiling plastering in CM 1:3, 12 mm thick including necessary scaffolding, water the surface etc all complete as per standard specification.
635Laying cement concrete flooring of 100 mm thick with Plain Cement Concrete 1:4:10, using 40 mm HBG stone and smooth finish etc all complete as per standard specifications
636Granolithic flooring 40mm thick cement concrete 1:2:4 mix using 3-10mm chips and top surface rendered smooth with cement including thread lining etc. as per directed by Engineer in-charge
637Refilling in excavated trenches and basement using excavated earth including complete consolidation and levelling as per standard specifications
638Concrete with broken brick jelly 20mm gauge in pure slacked lime over RCC roof slab in the proportion of 32:12 1/2 no sand to be used well beaten with wooden beaters with the required depth of 80mm thick and giving required slope and thickness to roof as required etc. complete.
639Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection >0.70 and initial emittance >0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner.
640White washing the plastered walls and ceiling with best shell lime including preparation of surface and neat finishing with 2 coats etc, complying with standard specification and as directed by the Departmental Engineer etc, complete (Inside & outside)
641Colour washing the plastered walls and ceiling with approved colour over the white washed area with neat finishing of 2 coats etc, complying with standard specification and as directed by the Departmental Engineer etc, complete (Inside & outside) - same as white washing
642Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
643a) Doors
644Teakwood panelled door in double shutter with frames 100x75mm side verticals and top. A shutter shall be 40mm thick with moulded panels in 20mm thick 4 no. of iron hold fast fixed in C.C 1:2:4 using 6 to 10mm chips 3nos. Of butt hinges 125mm long including wind appliances, furniture iron fittings, one No. of iron pad lock 15cm long for locking arrangements and fixed in position etc complete.
645b) Window
646Teakwood T.W glazed swig ventilator with frame 75x60mm all-round shutter shall be 40mm thick 3 mm glass panels including 20x20 teak fillets, sash centres, brass rings iron leaf and window card applications including fixing and position etc. complete.
647PVC syntax door in single shutter with frame of size 100x75mm at side verticals on the top with locking arrangement etc. complete for toilet
648Providing and fixing in position of Rolling Shutter of size (2.5 x 3 m) including all necessary permanent fittings as per standard specifications and as directed by the Departmental Engineer etc, complete
649Supplying and fixing of MS grating with Chequered plate of 6 mm thick over the cable trench as directed by Departmental Engineer etc all complete as per standard specifications.
650Painting of panelled doors and windows with 2 coats of enamel paint including a coat of primer, including scraping, sand papering and preparation of surface including cost of brushes, with neat finishing etc all complete as per standard specifications.
651Painting of Rolling shutter with 2 coats of paint including a coat of primer, scraping, sand papering and preparation of surface including cost of brushes, with neat finishing etc all complete as per standard specifications.
652Supplying fixing 75mm dia.AC rainwater down fall pipe including cost of bends, anchors etc.
653Providing fixing MS grills for window including one coat of primer with red lead and painting etc. complete as directed.
654Provision for Rainwater harvesting arrangements as per municipal specifications
655Civil Works of SPS -3
656SCREEN WELL (3.0 m F )
657Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
658For 0 to 2 m depth
659Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
660For 2 to 3 m depth
661For 3 to 4 m depth
662Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
663For 4 to 5 m depth
664For 5 to 6 m depth
665For 6 to 6.71 m depth
666Supplying & laying Reinforced Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
667Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
668Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm dia.meter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
669Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
670Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
671Transportation of earth from the site to disposal site at a minimum distance of 5 km from the site
672Providing and fixing of MS screens of dimensions as shown in drawings with MS flats of 20 x 50 mm with c/c spacing of 25 welded to angle frame of 100 x 100 x 8 mmetc all complete
673MS Rugs
674GRIT WELL (2.0 m F )
675Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
676For 0 to 2 m depth
677Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
678For 2 to 3 m depth
679For 3 to 4 m depth
680Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
681For 4 to 5 m depth
682For 5 to 6 m depth
683For 6 to 7 m depth
684For 7 to 7.81 m depth
685Supplying & laying Reinforced Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
686Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
687Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm dia.meter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
688Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
689Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
690Transportation of earth from the site to disposal site at a minimum distance of 5 km from the site
691MS Rugs
692WET WELL (4 m F )
693Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
694For 0 to 2 m depth
695Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
696For 2 to 3 m depth
697For 3 to 4 m depth
698Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department
699For 4 to 5 m depth
700For 5 to 6 m depth
701For 6 to 7 m depth
702For 7 to 8 m depth
703For 8 to 9 m depth
704For 9 to 9.41 m depth
705Supplying & laying Reinforced Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
706Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
707Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm dia.meter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
708Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
709Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
710Transportation of earth from the site to disposal site at a minimum distance of 5 km from the site
711MS Rugs
712MECH WORKS OF SPS - 3 (PIPING VALVES & APPURTENANCES)
713Screen Chamber
714Supply and delivery of 250 mm, DI (CL), Class K7 per IS 8329-2000 flanged ends including specials and appurtenances
715Fabrication, supply and installation of manually cleaned CI bar screen (50 x 10 mm thk) complete with grouting and epoxy coating, weighing approx. 4.70 kg/m
716Supply and installation of CI Sluice Gate suitable for inlet sewer pipe 250 mm dia.., raised spindle, single face, wall thimble mounted, bottom closing, flanged backframe, as per IS:13349:1991 class 1 including headstock, guide collar, epoxy painted, per specifications and as directed by the Engineer-in-charge
717Supply and delivery of sewer outlet pipe connected to Grit Well, 250 mm, DI (CL) flanged, Class K7 per IS 8329-2000 including specials and appurtenances
718Grit Well & Grit Removal Pit
719Supply and installation of CI Sluice Gate suitable for inlet sewer pipe 250 mm dia.., raised spindle, single face, wall thimble mounted, bottom closing, flanged back frame, as per IS:13349:1991 class 1 including headstock, guide collar, epoxy painted, per specifications and as directed by the Engineer-in-charge
720Supply and installation of grit removal and overflow pipe, flanged DI (CL), 250 mm
721Sewer outlet pipe connected to Suction Well, 250 mm, DI (CL) flanged ends
722Suction Well
723NON-RETURN BALL VALVE: Supply and installation at site, CI Ball valve suitable for sewage service, 80 mm, CI, flanged ends with support concrete pad
724NON-RETURN BALL VALVE: Supply and installation at site, CI Ball valve suitable for sewage service, 150 mm, CI, flanged ends with support concrete pad
725Supplying and Conveying CI Double Flanged Sluice Valves (PN 1.0) with capconfirming to IS:14846, to site, including flanged tail pieces and other specials as required, loading, unloading, transportation charges & stacking at site etc. complete per specifications and as directed by the Departmental Engineer. -80 mm
726Supplying and Conveying CI Double Flanged Sluice Valves (PN 1.0) with capconfirming to IS:14846, to site, including flanged tail pieces and other specials as required, loading, unloading, transportation charges & stacking at site etc. complete per specifications and as directed by the Departmental Engineer. -150 mm
727Supply and delivery of discharge pipe, 80 mm, DI (CL), PN 10 flanged pipe per IS flanged ends including appurtenances
728Supply and delivery of discharge pipe, 150 mm, DI (CL), PN 10 flanged pipe per IS flanged ends including appurtenances
729Supply and installation of 2 Ton capacity hand operated Over Head Travelling crane, for a span of 6 m, travel up to 10 m and lift of 6 m including gear type chain pulley block and geared travelling trolley complete with civil works and accessories
730Pipe Appurtenances (Specials)
73190 deg bend, DI (CL) flanged, 150-mm dia.., 3 Nos.
73290 deg bend, DI (CL) flanged, 200-mm dia.., 1 No.
733250 x 250 X 200 mm flanged Tee, DI (CL), 3 Nos.
734250 x 250 X 200 mm flanged Tee, DI (CL), 1 No.
735Blank Flanges with fasteners, DI, 200 mm, 2 Nos.
736Blank Flanges with fasteners, DI, 150 mm, 6 Nos.
737Reducer 200 x 150 mm
738Pumping Main
739Supplying, conveying of DI flanged pipe PN 10 min, 150 mm dia.meter Class K-9 as per IS:8329-2000, including all specials, transportation charges, loading, unloading etc., complete as per standard specifications and as directed by the Engineer-in-charge
740Laying, jointing of DI pipe, 150 mm dia.meter class k9 including earthwork excavation for sewer line trenches in hard stiff clay, black cotton, hard red earth, shales, murrams, gravels, stony earth and earth mixed with small size boulders and hard gravel.
741Providing Sand Bedding for the pipe line trenches including watering and consolidation complete with an initial lead of 50 m etc.
742Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stony earth and earth mixed with small size of boulders as directed by Departmental engineer.
743Refilling pipeline trenches and foundation with selected available earth from trench excavation and foundation including watering, consolidation in layers of 15 cm, thickness including disposing off the surplus earth with a lead of 200 m.
744ELECTRICAL WORKS OF SPS - 3
745Pumping Equipment
746Supply and installation of SUBMERSIBLE SEWAGE PUMPS: Non-clog type, single stage - single suction - CF8M impeller - in standard construction fitted with double mechanical seal for gland sealing with integrated oil chamber and sensor, complete with duck foot bend, lifting lug and pedestal coupling assembly as per reference TWAD Spec & relevant IS complete.
74733 cum/hr@ 27 m TDH - 1 Operating + 1 Standby
748100 cum/hr@ 27 m TDH - 1 Operating + 1 Standby
749Supply and installation of MS Galvanized Guide Pipe with wall mount plate and fasteners, suitable lengths
750Supply and installation of MS Galvanized lifting chain, standard length for each pump installed
751SUBMERSIBLE GRIT REMOVAL PUMP - Non-clog type; single stage - single suction - CF8M impeller with SS grit cutter manifold - in standard construction fitted with oil-lubricated double mechanical seal for gland sealing with integrated oil chamber/sensor and flexible flanged discharge hose, 45 cu.m./hr, 10m H, 7.5 HP
752Electrical Equipment
753Supply and Installation of TNEB METERING BOARD complete suitable for 3-phase 25 KW load with following provisions (included):
754a) 100 A fuse cut-out 3 nos.
755b) 124 A TPN SFU
756c) 1 no. 63A Neutral link
757d) 1 no. 4-way earth plate with bolts-nuts
758e) 0-400 V voltmeter and 3 nos. indicator lamps for 3-phase in suitable MS Box with all interconnection wire and space for TNEB meter
759Above items shall be mounted on min. 6-mm thick Hylam Sheet and with angle supports on wall at a suitable location as directed by Dept Engr
760Supply and installation of LT Panel complete with Incomer and Outgoing Feeders complete with MCCB, selector switch, energy meter, fuses and all requisite accessories (Manufacturer Rate)
761Incomer - Two Nos
762125A 4P 35KA MCCB
763C.Ts 200/5A
764Ammeter, Selector Switch
765Voltmeter, Selector Switch
766KWH Meter
767PFMeter
768Indication Lamp
769Control Fuses
770Castle Inter Lock
771OUT GOING FEEDERS
77263A,TPN,50KA,MCCB
773C.Ts 40/5A
774Standard Metering Panel with Ammeter, Voltmeter and indicators
77532A,TPN,50KA,MCCB
776C.Ts 40/5A
77732A TPN MCB
77810A DP MCB
779Shell
780Busbar
781Insulators Sleeve
782Wire coils
783Erection
784Earthing arrangements as per IE rules
785Supply and Installation of one (1) Diesel Generator complete with mounting pad, exhaust manifold, change-over and accessories
786415V / 1,500 RPM / 20 KVA (BHP-83)
787Installation Cost
788Supply and Installation of Main Control Panel for Submersible Pumps, complete with ammeter and single phase preventer, push button control and accessories (rated for 3+1 nos, 5 HP ea.)
789Vendor Rate
79063A TPN SFU With HRC fuse
791CT 40/5A
792Ammeter, Selector Switch (0-40)A
793Voltmeter Selector Switch (0-500)v
79425A Power contactor (MN25,15KVAr)
795OLR 14-23A
796Indication lamp
797Timer (0 - 30)sec
798Auxiliary contactor
799Push button
800Under voltage relay
801Thermal relay
802Level control
803Moisture control
804Single phase preventer
805Shell
806Wires & TBs
807Miscellaneous
808Installation charges
809MS Outdoor box with painted (optional only if open mounted)
810Push button
811Supply and Installation of Pump Control Panels for submersible pumps, complete with selector switch, relay, phase preventer, push button control and accessories.
812Supply and installation of one Direct-on-Line Starter suitable for One (1) Grit Removal submersible pump, rated at 1 HP, complete with accessories and mounting arrangement
813Supply and installation of one Direct-on-Line Starter suitable for one(1) general utility water supply pump, rated at 1 HP, complete with accessories and mounting arrangement for 1HP pump
814Supply and Laying of Power and Control Cables from TNEB Panel to LT Panel and onward to all components and to DG Set complete with termination
815EB,DG to L.T panel to motor, starter, power cables
8164C x 16 sq.mm Al.Arm cable.
8173C x 10 sq.mm Al.Arm cable.
8183C x 6 sq.mm Al Arm cable
8193C x 4 sq.mm Al Arm cable
820Control Cables:
8214C x 1.5 sq.mm Cu flexible cable
8227C x 1.5 sq.mm CU.Arm cable.
8233C x 4 sq.mm Al.Arm cable.
824Termination for the following cables with necessary accessories
8254C x 16 sq.mm Al.Arm cable.
8263C x10 sq.mm CU Arm cable
8273C x 6 sq.mm Al Arm cable
8284C x 1.5 sq.mm CU.Arm cable.
8297C x 1.5 sq.mm CU.Arm cable.
8303C x 4 sq.mm. Al. Arm cable.
831Supply and installation of earthing (grounding) arrangement for all electrical equipment complete with accessories.
832100mm CI pipe with funnel, clamp 3mts long
833CI cover plate
834Sand /charcoal/salt
835Masonry
836Supply of 25x3mm Cu flat (100 m approx.)
837Supply & laying of 10 SWG CU wire
838Earth pit Erection
839Supply and Installation of Indoor and Outdoor Light fittings, cables, cut-outs and fans complete with accessories and mounting
840Supply and installation of four way TPN DB\"s
8414 way TPN DB
84263A 4P MCB as incomer
84332A TPN MCB as out going
844SPN DB\"S :
8456 Way SPN Lighting DB
84632A DP MCB 30mA ELCB as incomer
8476A SPN MCB Outgoing
848Angle Iron Frame, Erection
849LIGHT FITTINGS
850Industrial type florescent lamp 2x40w(local rate)
851Decorative type florescent lamp 2x40w
852Street light fitting fluorescent 1x40w
853Bulk head fitting 100/60w
8546m tubular street light poles - GI 65 mm
855200x200x50mm MS box
85610A MCB
857Sodium vapour lamp 125w(local rate)
858Terminal block 6 way suitable for 4 sq.mm. Cable
859WIRING
860Point wiring surface / concealed for lighting points with copper wire
861Point wiring surface / concealed for 6A /16 A (1ph,3pin) switch socket
862Supply and delivery of the following safety equipment and tools
8635KG capacity dry chemical powder type fire extinguisher
864Wooden First aid box.
865Fire bucket stand with 3 round bottom bucket
866Rubber mat of 1.1KV grade of size 6mmthick
867Fire safety rules chart.( Local Rates).
868Shock treatment chart
869Supply and delivery of the following maintenance tools/equipment:
870Socket set with hi-hexagon socket made up of chromium vanadium steel with attachment for 1 1/2\"\" square drive in metal box from 8mm to 32mm consisting of 22 nos.(Local Rates).
871Adjustable wrench made up of selected carbon steel with standard pattern of size 200mm
872Double ended open jaw spanner set
873Screw driver set consisting of various sizes of(6\"\",8\"\",12\"\").(Local Rates).
874Cutting plair 12\"\".(Local Rates).
875Hacksaw frame with blade
876Supply and Fixing GI Pipe with bends etc. on angle Iron supports and providing 4 runs of 10 sqmm PVC Cu with reel insulator and 7/11 stay wire between TNEB Post and Meter Board
877Complete as directed and approved by Dept Engr after confirmation from TNEB Authorities
878Liaisoning charges and payment of service connection fee and security deposit to TNEB including development charges
879CONTROL ROOM FOR SPS -3
880Earth work excavation for foundation & depositing on bank with an initial lead of 10 m & lift of 2 m for depths in hard stiff clay, stiff black cotton, hard red earth mixed with small sized boulders & hard gravely soil, including dewatering of water etc.,
881Supplying and filling with sand for foundation and basement including watering consolidating ramming etc complete.
882Providing and laying base concrete in foundation using Plain Cement Concrete 1:4:8 including consolidation and levelling etc as per standard specifications
883Providing Form work with centering for soffits of reinforced cement concrete slab or plain surfaces including strutting up to 3m.
884Reinforced cement concrete 1:2:4 excluding form work and reinforcement for RCC works as detailed in drawings and as per standard specifications and as directed by the Departmental Engineer etc. complete
885Laying C.C. 1:2:4 for RCC sunshade work using 20mm hard broken stone jelly 80mm thick at wall end and 50mm thick at free end projecting 600mm from wall face moulded along with RC lintels excluding the cost of reinforcement including centering compacting curing etc. complete as directed by Engineer in-charge
886Reinforcement for RCC works
887Construction of brick masonry with class II bricks in CM 1:6 in foundation including curing etc all complete as per standard specifications.
888Construction of brick masonry with class II bricks in CM 1:6 in superstructure including curing etc all complete as per standard specifications.
889Inside plastering in CM 1:4, 12 mm thick including necessary scaffolding, water the surface etc all complete as per standard specification.
890Outside plastering in CM 1:4, 15 mm thick including necessary scaffolding, watering the surface etc all complete as per standard specification.
891Ceiling plastering in CM 1:3, 12 mm thick including necessary scaffolding, water the surface etc all complete as per standard specification.
892Laying cement concrete flooring of 100 mm thick with Plain Cement Concrete 1:4:10, using 40 mm HBG stone and smooth finish etc all complete as per standard specifications
893Granolithic flooring 40mm thick cement concrete 1:2:4 mix using 3-10mm chips and top surface rendered smooth with cement including thread lining etc. as per directed by Engineer in-charge
894Refilling in excavated trenches and basement using excavated earth including complete consolidation and levelling as per standard specifications
895Concrete with broken brick jelly 20mm gauge in pure slacked lime over RCC roof slab in the proportion of 32:12 1/2 no sand to be used well beaten with wooden beaters with the required depth of 80mm thick and giving required slope and thickness to roof as required etc. complete.
896Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection >0.70 and initial emittance >0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner.
897White washing the plastered walls and ceiling with best shell lime including preparation of surface and neat finishing with 2 coats etc, complying with standard specification and as directed by the Departmental Engineer etc, complete (Inside & outside)
898Colour washing the plastered walls and ceiling with approved colour over the white washed area with neat finishing of 2 coats etc, complying with standard specification and as directed by the Departmental Engineer etc, complete (Inside & outside) - same as white washing
899Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
900a) Doors
901Teakwood panelled door in double shutter with frames 100x75mm side verticals and top. A shutter shall be 40mm thick with moulded panels in 20mm thick 4 no. of iron hold fast fixed in C.C 1:2:4 using 6 to 10mm chips 3nos. Of butt hinges 125mm long including wind appliances, furniture iron fittings, one No. of iron pad lock 15cm long for locking arrangements and fixed in position etc complete.
902b) Window
903Teakwood T.W glazed swig ventilator with frame 75x60mm all-round shutter shall be 40mm thick 3 mm glass panels including 20x20 teak fillets, sash centers, brass rings iron leaf and window card applications including fixing and position etc. complete.
904PVC syntax door in single shutter with frame of size 100x75mm at side verticals on the top with locking arrangement etc. complete for toilet
905Providing and fixing in position of Rolling Shutter of size (2.5 x 3 m) including all necessary permanent fittings as per standard specifications and as directed by the Departmental Engineer etc, complete
906Supplying and fixing of MS grating with Chequered plate of 6 mm thick over the cable trench as directed by Departmental Engineer etc all complete as per standard specifications.
907Painting of panelled doors and windows with 2 coats of enamel paint including a coat of primer, including scraping, sand papering and preparation of surface including cost of brushes, with neat finishing etc all complete as per standard specifications.
908Painting of Rolling shutter with 2 coats of paint including a coat of primer, scraping, sand papering and preparation of surface including cost of brushes, with neat finishing etc all complete as per standard specifications.
909Supplying fixing 75mm dia.AC rainwater down fall pipe including cost of bends, anchors etc.
910Providing fixing MS grills for window including one coat of primer with red lead and painting etc. complete as directed.
911Provision for Rainwater harvesting arrangements as per municipal specifications
912Pilling Works at all SPS
913Providing, driving and installing driven cast-in-situ reinforced cement concrete piles of grade M-30 of specified dia.meter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost ofshoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) :-250 mm dia..
914Screen Well & Grit Well at SPS 1 to3
915Suction Well at SPS 1 to3
916Lift Stations - 6 nos.
917Mild steel bars 10mm dia. and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips.@80 kg/m3 of concrete
918Providing MS shell of 6mm thick for piles - 250 mm dia..
919Screen Well & Grit Well at SPS 1 to 3
920Suction Well at SPS 1 to 3
921Lift Stations - 6 nos.
922Chipping and dressing of the RCC piles up to 0.6 m including cleaning reinforcement and removal of dismantled materials for providing pile caps etc. complete
923Providing pile cap over RCC piles
924Reinforced Cement Concrete in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed pilesand mass concrete. (M-30)
925Mild steel bars 10mm dia. and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia. or securing with clips.@80 kg/m3 of concrete
926Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile heador construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. - Max of 25% of piles at each loc.
927LIFTING STATION-1 (Civil Work)
928Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Departmental engineer
929For 0 to 2 m depth
930Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Department engineer
931For 2 to 3 m depth
932For 3 to 4 m depth
933For 4 to 5 m depth
934For 5 to 6 m depth
935For 6 to 7 m depth
936For 7 to 8 m depth
937For 8 to 8.439 depth
938Supplying & laying Reinforced Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
939Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
940Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm dia.meter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
941Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
942Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
943Carting of excavated surplus soil away from site including cost for all items of work, men, materials, machinery, equipment as per standard specification and as directed by Engineer-in-charge
944MS encapsulated PVC steps
945LIFTING STATION-1 (Mech. Work)
946NON-RETURN BALL VALVE: Supply and installation at site, C .I. Ball valve suitable for sewage service, 100 mm, CI, flanged ends with support concrete pad
947Supplying and Conveying CI Double Flanged Sluice Valves (PN 1.0) with cap of 100 mm confirming to IS:14846, to site, including flanged tail pieces and other specials as required, loading, unloading, transportation charges & stacking at site etc. complete per specifications and as directed by the Engineer
948Supply and delivery of discharge pipe, 100 mm, DI (CL), Class K9 per IS 8329-2000 flanged ends with leak-proof gasket installation including appurtenances
949Supply and delivery of following pipe appurtenances and specials DI (CL), Class K7 per IS 8329-2000 flanged ends with leak-proof gasket installation including cost for procurement, supply, delivery, fixing, testing etc. and necessary engineering and labour charges in accordance with standard specifications and as directed by Engineer
95090 deg bend, DI (CL) flanged, 100-mm dia.., 2 Nos.
951Blank Flanges with fasteners, DI, 100 mm, 2 Nos.
952Pumping Main
953Earthwork excavation & depositing on bank with an initial lead of 10 m & lift of 2 m for depths in hard stiff clay, stiff black cotton, hard red earth mixed with small sized boulders & hard gravely soil including dewatering of water as and when required, barricading with safety lamps etc all complete as per standard specification as directed by the Engineer.
954Supplying, conveying of DI pipe, 100 mm dia.meter Class K-9 as per IS:8329-2000, with leak-proof gasket installation including all specials, transportation charges, loading, unloading, Lowering pipes and specials into trench and laying to proper grade and alignment, jointing, hydraulic testing etc all complete as per standard specifications and as directed by the Engineer-in-charge
955Lowering pipes and specials into trench and laying to proper grade and alignment, jointing, hydraulic testing etc all complete as per standard specifications and as directed by the Engineer-in-charge
956Supplying & providing sand bedding for the sewer line trenches including watering and consolidation etc complete as per standard specifications and as directed by Engineer-in-charge
957Dismantling of existing flexible pavement and depositing of dismantled materials along roadside or at a safe location as directed by Engineer-in-Charge
958Restoration of Road along the excavated and refilled portion of sewer pipeline trenches in accordance with applicable standard specifications and as directed by Engineer-in-charge
959Refilling pipeline trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm, thickness including disposing off the surplus earth at a safe location as directed by Engineer-in-charge
960Mechanical Works
961Supply and installation of MS Galvanized Guide Pipe with wall mount plate and fasteners
962Supply and installation of MS Galvanized lifting chain forpump installed
963LIFTING STATION-1 (Elect. Work)
964Supply and installation of SUBMERSIBLE SEWAGE PUMPS: Non-clog type, single stage - single suction - CF8M impeller - in standard construction fitted with double mechanical seal for gland sealing with integrated oil chamber and sensor, complete with all accessories andassembly as per reference TWAD Spec & relevant IS complete.
9654.50 cum/hr@ 24 m TDH - 1 Operating + 1 Standby
966Supply and Installation of TNEB METERING BOARD complete suitable for 3-phase 10 KW load with following provisions (included):
967a) 100 A fuse cut-out 3 nos.
968b) 124 A TPN SFU
969c) 1 no. 63A Neutral link
970d) 1 no. 4-way earth plate with bolts-nuts
971e) 0-400 V voltmeter and 3 nos. indicator lamps for 3-phase in suitable MS Box with all interconnection wire and space for TNEB meter
972Above items shall be mounted on min. 6-mm thick Hylam Sheet and with angle supports on wall at a suitable location as directed by Dept Engr
973Supply and Installation of LT Panel complete with Incomer and Outgoing Feeders complete with MCCB, selector switch, energy meter, fuses and all requisite accessories. (Manufacturer Rate)
974Incomer - EB supply
975125A 4P 35KA MCCB (MES SOR Rate Only for 160A available)
976C.Ts 125/5A
977Standard Metering Panel with Ammeter, Voltmeter and indicators
978Voltmeter, Selector Switch
979KWH Meter
980Indication Lamp
981Control Fuses
982Castle Inter Lock
983Incomer -DG supply
984125A 4P 35KA MCCB (MES SOR Rate Only for 160A available)
985OUT-GOING FEEDERS
98632A TPN MCCB
987C.Ts 20/5A
988Shell
989Busbar
990Insulators Sleeve
991Wire coils
992Erection
993Earthing arrangements as per IE rules
994Supply and installation of trolley mounted Diesel Generator, rated at 415v/1500 RPM/10 KVA (Manufacturer Rate)- Cost including trolley mounting, trolley, under-carraige, wheel/axle, tackle/hook/link chain and related for suitably tethering to a power vehicle
995ONLY TWO SETS FOR ALL LIFT STATIONS
996Supply and Installation of Pump Control Panels for Submersible Pumps, complete with Ammeter and single phase preventer, push button control and accessories. For 1 HP.
997MS outer box with painted
998push button
999Erection
1000Supply and Laying of Power control cables from TNEB panel to LT panel and onward to all components and to DG set interconnection box/ panel etc complete w termination. All Lengths as actually required and only used by Contractor and as directed by Dept. Engr.
1001EB,DG to L.T panel to motor, starter, .(power cables)
10023 1/2C x 35 sq.mm Al.Arm cable.
10033C x 16 sq.mm Al Arm cable
10043C x 10 sq.mm Al Arm cable
10053C x 4 sq.mm Al Arm cable
1006Control cables
10074C x 1.5 sq.mm CU.Arm cable.
10083C x 4 sq.mm Al Ar Cable
10097C x 1.5 sq.mm. Flexible Cu Cable
1010Termination for the following cables with necessary accessories.
10113 1/2C x 35sq.mm Al.Arm cable.
10123C x 16 sq.mm Al Arm cable
10133C x 10 sq.mm Al Arm cable
10143C x 4 sq.mm Al Arm cable
10154C x 1.5 sq.mm CU.Arm cable.
1016Supply and installation of cable trays for power and control cables
1017600 mm ladder type galvanized cable trays
101840 x 6mm angles, grouted on wall
1019Supply and installation of earthing (grounding) arrangement for electrical equipment complete with accessories.
1020100mm CI pipe with funnel, clamp 3mts long
1021CI cover plate
1022Sand /charcoal/salt
1023Masonry
1024Supply of 25x3mm Cu flat (30mts)
1025Supply & laying of 10 SWG CU wire
1026Earth pit Erection
1027Supply and installation of Indoor and Outdoor Light fittings, cables, cut-out and ventilation fans complete with accessories and mounting
1028Supply and installation of four way compartmentalized DBs
1029Supply and installation of four way TPN DBs
10304 way TPN DB
103163A 4P MCB as incomer
103232A TPN MCB as out going
1033SPN DB\"S :
10346 Way SPN Lighting DB
103532A DP MCB 30mA ELCB as incomer
10366A SPN MCB Outgoing
1037Angle Iron Frame, Erection
1038LIGHT FITTINGS
1039Industrial type florescent lamp 2x40w
1040Decorative type florescent lamp 2x40w
1041Street light fitting fluorescent 1x40w
1042Bulk head fitting 100/60w
10436m tubular street light poles GI 65 mm
1044200x200x50mm MS box
104510A MCB
1046Terminal block 6 way suitable for 4 sq.mm. Cable
1047WIRING
1048Point wiring surface/concealed for lighting points
1049Point wiring surface / concealed for 6A /16A (1ph,3pin) switch socket
1050Point wiring surface / concealed for fan/exhaust fan
1051Supply installation testing & commissioning of the following types of ventilation fans complete with accessories, mounting and fasteners.
1052AC ceiling fan 48\"\"
1053AC Exhaust fan 12\"\" light duty
1054Plug & Sockets 20A DP
1055Supply and delivery of the following safety equipment and tools
10565KG capacity dry chemical powder type fire extinguisher
1057Wooden First aid box
1058Fire bucket stand with 3nos round bottom buckets
1059Rubber mat of 1.1KV grade of size 6mmthick. (Ref ,TWAT SOR 2003-04,Pg 146 item iii)
1060Fire safety rules chart.( Local Rates).
1061Shock treatment chart
1062Supply and delivery of the following maintenance tools/equipment:
1063Adjustable wrench made-up of selected carbon steel with standard pattern of size 200mm
1064Double ended open jaw spanner set
1065Screw driver set consisting of various sizes of(6\"\",8\"\",12\"\").(Local Rates).
1066Cutting pliers 12\"\".(Local Rates).
1067Hacksaw frame with blade
1068Supply and Fixing GI Pipe with bends etc. on angle Iron supports and providing 4 runs of 10 sqmm PVC Cu with reel insulator and 7/11 stay wire between TNEB Post and Meter Board
1069Complete as directed and approved by Dept Engr after confirmation from TNEB Authorities
1070Liaisoning charges and payment of service connection fee and security deposit to TNEB including development charges
1071Control Room for Lifting stations (Where Space is available )
1072Earth work excavation for foundation & depositing on bank with an initial lead of 10 m & lift of 2 m for depths in hard stiff clay, stiff black cotton, hard red earth mixed with small sized boulders & hard gravely soil, including dewatering of water etc.,
1073Providing and laying base concrete in foundation using Plain Cement Concrete 1:4:8 including consolidation and leveling etc as per standard specifications
1074Construction of brick masonry with class I bricks in CM 1:6 in foundation including curing etc all complete as per standard specifications.
1075Construction of brick masonry with class II bricks in CM 1:6 in superstructure including curing etc all complete as per standard specifications.
1076Inside plastering in CM 1:4, 12 mm thick including necessary scaffolding, water the surface etc all complete as per standard specification.
1077Outside plastering in CM 1:4, 20 mm thick including necessary scaffolding, watering the surface etc all complete as per standard specification.
1078Ceiling plastering in CM 1:4, 12 mm thick including necessary scaffolding, water the surface etc all complete as per standard specification.
1079Reinforced cement concrete 1:2:4 including form work and reinforcement for top roof slab and sunshade as detailed in drawings and as per standard specifications and as directed by the Departmental Engineer etc. complete
1080Laying cement concrete flooring of 100 mm thick with Plain Cement Concrete 1:2:4, using 10 to 12.5 mm HBG stone and smooth finish etc all complete as per standard specifications
1081Refilling in excavated trenches and basement using excavated earth including complete consolidation and leveling as per standard specifications
1082White washing the plastered walls and ceiling with best shell lime including preparation of surface and neat finishing with 2 coats etc, complying with standard specification and as directed by the Departmental Engineer etc, complete (Inside & outside)
1083Colour washing the plastered walls and ceiling with approved colour over the white washed area with neat finishing of 2 coats etc, complying with standard specification and as directed by the Departmental Engineer etc, complete (Inside & outside) - same as white washing
1084Supplying and fixing of MS grating with Chequered plate of 6 mm thick over the cable trench as directed by Departmental Engineer etc all complete as per standard specifications.
1085Providing and fixing in position Country wood paneled doors and windows as specified below and as per standard specifications
1086Painting of paneled doors and windows with 2 coats of enamel paint including a coat of primer, including scraping, sand papering and preparation of surface including cost of brushes, with neat finishing etc all complete as per standard specifications.
1087SINTEX PACKAGED WASTEWATER TREATMENT SYSTEM
1088Earth work excavation and depositing on bank with initial lead of 10 m and initial lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stony earth and earth mixed with small size of boulders as directed by Dept Engr - Embed Depth 1.5 m + RCC Conc Pad 0.1 m + 0.1 m Foundation Pad in 1:5:10
1089For 0 to 2 m depth
1090Supplying & laying Reinforced Cement Concrete of M25 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations, floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured & paid under separate items) including curing, complying with standard specifications as directed by the Departmental Engineer using sulphate resisting cement.
1091Providing and laying base concrete in foundation using Plain Cement Concrete 1:5:10 As base course (40 mm) including consolidation and levelling etc as per standard specifications
1092Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm dia.meter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
1093Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
1094Refilling the trenches with suitable excavated earth available in layers of 150 mm thick, watering, ramming & consolidation as directed by the Departmental Engineer.
1095Transportation of earth from the site to disposal site at an average lead transport of 5 km from the site
1096Supply, Transport, Delivery and Installation of Sinter Packaged Wastewater Treatment System (PWTS) Advanced Septic Tank of suitable Capacity at specified location as specified including provision of all necessary accessories and fittings such as Inlet and Outlet manifold, Manhole Access Cover, Internal Materials for Sewage Treatment, Ventilation Shaft and Bird screen, fasteners etc complete as per Standard Specifications (All costs included for delivery to project site as directed by Dept Engr.)
1097Model PWTS - AM - 80 - 1
1098Model PWTS - AM - 160 - 1
1099Add 10% for all accessories
1100Add 10% for transport to site
1101Supply and installation of SUBMERSIBLE SEWAGE PUMPS: Non-clog type, single stage - single suction - CF8M impeller - in standard construction fitted with double mechanical seal for gland sealing with integrated oil chamber and sensor, complete with duck foot bend, lifting lug and pedestal coupling assembly as per reference TWAD Spec & relevant IS complete.
11021 HP Rated pump of min Flow & TDH
11031 HP Rated pump of min Flow & TDH
1104Supply and installation of MS Galvanized Guide Pipe with wall mount plate and fasteners, suitable lengths for hoisting sewage pump from manhole for repairs/ renewals / replacement
1105Supply and installation of MS Galvanized lifting chain, standard length for each pump installed for hoisting sewage pump from manhole for repairs/ renewals / replacement
1106Sewage treatment and disposal Facility
1107Designing, providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of 2.0 MLD Sewage treatment plant based on Cyclic Activated Sludge Process technology and 2.0 Mld Tertiary Treatment plantin M30 RCC grade consisting of Raw sewage pumpingInlet Chamber, Screen Chamber, Detritus Tanks, Distribution Chamber/box and Biological CASP Basinstank, Sludge Sump, Centrifuge house, Chlorine Contact Tank, Chlorinator Room/Shed, Sludge Centrifuge, Including tertiary treatment plant of 2 Mld Capacitybased on fibre Disc filter technology including necessary piping work for the secondary and tertiary treatment plant with required valves, gates, drains, pathways, Administration Block cum Laboratory, Laboratory Equipments, Tools and Plants, Spare Parts, Internal roads, approach road to STP, Peripheral retaining wall around, DG platform, Storm water drains, security cabin,etc. complete as turnkey job with all involved civil, electrical and mechanical works inclusive of following items, units as per detailed specification for civil, electrical and mechanical components with all duties and taxes, etc. complete to achieve BOD < 5 ppm, COD < 100ppm, TSS < 5 ppm,to get recyclable quality of water for industrial / agricultural purposes, fire fighting, gardening etc. Plant is designed for N, P outlet parameters shall also include TN < 10 ppm, NH3N < 1 ppm and TP < 1 ppm)
11082.0 Mld STP and TTP
1109UNITS INCLUDED AS FOLLOWS
11101. Raw Sewage pumping Station and Pump house - Designing, providing, and constructing RCC (M-300) Receiving chamber, Coarse screen channel, Sewage pumping station and pump house, valve chamber for the peak flow of 3.0 DWF including necessary excavation in all types of strata including walkway all around the periphery.Each compartment will have phosphor bronze steel gates with extension rod, head stock, operating wheels, SS pipe railing, etc. The work includes providing and making necessary arrangements to connect the flow to screen chamber by approach channel as directed and as per specifications.
11111. Inlet Chamber-Designing, providing, and constructing RCC (M-300) inlet chamber for the peak flow of 3.0 DWF including necessary excavation in all types of strata including walkway all around the periphery.Each compartment will have phosphor bronze steel gates with extension rod, head stock, operating wheels, SS pipe railing, etc. The work includes providing and making necessary arrangements to connect the flow to screen chamber by approach channel as directed and as per specifications.
11122. Screen Chamber-Designing, providing, constructing, testing and commissioning of screen chamber, designed for average 1 DWF and maximum peak flow of 2.25 DWF in RCC (M-300), including inlet pipe / channel from inlet chamber, outlet pipe channel to detritus tank, free board of 0.5 m minimum, RCC walkway 1.2 m wide with SS pipe railing, RCC staircase of 1.2 m width from GL to screen chamber.
11133. Detritus Tank/ Grit Separator: Designing, providing and constructing continuous grit removal type DetritusTank, mechanically operated in RCC (M-300) capable of removing 100% of 0.2 mm size particle and above, having specific gravity 2.30, designed for one peak 3.0DWF with suitablearrangement of separation of grit from putrescible solids. Inlet and outlet channels of required sizes as may be required to connect the flow to connecting unit etc. complete including hydraulic testing for water tightness of structure having minimum FB of 0.3 m, washout arrangement to grit chamber and platform 1.2 m wide RCC walkway with SS pipe hand railing shall be provided. A pit for collecting grit conveyed by conveyor shall be provided. It should be suitable to handle the grit for carting. All arrangements shall be as detailed specifications and as directed.
11144. CASP Basins:Designing, providing and constructing in RCC (M-300), CASP basins for biological removal of BOD along with nitrification, denitrification, Bio-P removal in compartments to handle combine flow of 1 DWF incoming flow and recirculation flow including construction of selector compartments and providing 1.2 m wide clear approach walkways, expansion joints wherever necessary, including foundations, etc as per specifications. Peak factor shall be 2, F/M ratio shall be 0.15, complete with air blowers, fine diffused aeration grid / equipment and FB 0.5 m and SWD as required. DO level in basin to be minimum 2 mg/l complete with ‘Oxygen Uptake Rate’ control system and all related instruments, stainless steel decanters and automation works. MLSS concentrations shall be 2000-5500 mg/l or more. MLVSS to MLSS ratio to be 0.8. HRT shall be between 12 to 13 hrs and SRT suitable for fully digested sludge. It should have all other related works as per detailed specification. In case CASP is designed to achieve N,P removal HRT shall be between 15-18 hrs and SRT shall be suitably provided to fulley digested sludge. It should have all other related works as per detailed specifications.
11155. Chlorine Contact Tank :- Designing, providing and constructing chlorine contact chamber of adequate capacity to deal with 3.0 DWF average flow or Decanting flow whichever is higher. The chlorinecontact tank should be 30 min capacity, during average flow to achieve 99.99% coli form reduction. Chlorine dose shall be maintained as per standard provisions, including designing, providing and constructing water supply provision for chlorination including providing dewatering and bypass arrangement, jointing to final effluent mains and outlet weir, etc. complete. The effluent quality should match with the standards laid down by Maharashtra Water Pollution Control Board and as per obligatory provision and as detailed specification and as directed by Engineer-in-charge.
11166. Chlorinator and Chlorinator Room / Tonner Room - Designing, providing and constructing chlorinators vacuum type 2 Nos. with auto switchover facility and having capacity for dosage of adequate chlorine to ensure 99.99% coli form reduction as per obligatory provisions and detailed specifications with necessary provision of having chlorinator room of adequate size. The chlorinator equipment shall include cost of chlorine cylinders / tonner piping, valves, measuring and controlling equipments, safety devices, lifting equipments, etc. complete as per IS-10553 (Part II) 1982. The tonner room should have minimum 3 MT capacity hoist for loading and unloading facility. Tonner storage should be distinctly isolated and should be for minimum storage space as directed in the design specification and as per Gas Laws 1981 and Factory Act shall be provided. All other matching amenities shall be provided. 5 MT gantry rail shall be provided for full length of tonner room at 6 m height from level of tonner room, with outlet chamber and treated effluent outlet channel, etc. complete as per detailed specification.
11177. Sludge Sump:- Designing, providing and constructing of sludge sump and pump house of appropriate size with pumps, ceiling height minimum 5 m over sump for discharging sludge to centrifuge using CI pipe, etc. complete as per detailed specification.
11188. Sludge Centrifuge Platform with Centrifuges:-Designing, providing, constructing and installing including foundation etc., sludge centrifuge to handle the sludge flow of 1 day in 18 hours per unit with sludge dewatering unit, drain etc. complete as per specification. Sludge centrifuges with the necessary arrangement, as per detailed specification mentioned in tender and obligatory provisions to be provided with satisfactory functioning.
11199. Outfall Sewer:- Designing, providing and constructing appropriate outfall sewer of RCC NP2 pipe, to discharge treated effluent from outlet chamber after chlorination tank to the local nallah at the point shown on the drawing including necessary chamber for inspection and cleaning including necessary excavation, dewatering, refilling, concrete encasing / bedding concrete steps to reach the nallah bed level, pitching and energy dissipation chamber in nallah portion, etc. complete up to 50 m length RCC NP2 pipe line and including all above items.
112010. Piping Work in CI-LA class including Sluice Valves, Reflux Valves, MSEP Gates:- Providing, laying and jointing pipes other than those already included in the above items for interconnection, bypass drains, etc. of all units including adequate number of manhole chambers. The item includesexcavations, refilling and hydraulic testing of pipes, valves, gates, accessories and cost of jointing materials. The items includes required channels with gates for interconnection of units, bypass drains, etc. for all units as directed, etc complete as per detailed specifications.
112111. Administrative Building cum Laboratory (G+1):- Designing, providing and constructing administrative building, office cum laboratory including stores. This shall be a building having appropriate carpet area at ground floor and at first floor complete as per specifications including necessary excavation, foundation in RCC M-200 framed structure BB masonry (second class in C.M. 1:6), 20 mm cement plaster in CM 1:3 inside and outside painting. Aluminium door and window with glass panels, mosaic tile flooring and skirting and all other allied items, fixtures, fastening, electrification arrangement, water supply arrangement, etc. complete.The building will have laboratory on upper floor of administrative building and should be so centralized that it should not be attached with any unit but should have complete control of every unit as per laboratory equipment, beautification, telephone and intercom arrangement and wireless system.
1122NOTE: All the Structural Steel works/ Fabrications are to be provided with Hot Dip Zinc Coating according to specifications as per IS 4759:1996 (Reaffirmed 2006)
1123Note: The cost of STP includes cost of foundation (Any Type including Piling with liner 4 mm thk. Min. 500 mm dia /Raft/Isolated etc.) for SPS, STP and TTP
1124Construction of retaining wall at property boundary adjoining Nullah Side
1125Earth work excavation and depositing on bank with an initial lead of 10 m & lift of 2 m for depths in hard stiff clay, stiff black cotton, hard red earth, shales murum, gravel, stony earth and earth mixed with small size of bouldersetc all complete as per standard specification as directed by the Departmental Engineer.
1126a) For 0 to 2 m depth
1127b) For 2 to 4m depth
1128Earth work excavation and depositing on bank with an initial lead of 10 m & lift of 2 m for depths in hard stiff clay, stiff black cotton, hard red earth, shales murum, gravel, stony earth and earth mixed with small size of bouldersetc all complete as per standard specification as directed by the Departmental Engineer.
1129for 2 to 3 m depth
1130Supplying and laying of Reinforcement Cement Concrete of M30 grade using machine crushed hard broken granite stone jelly 20 mm for RCC works in all types of foundations floor slabs of all shapes (Excluding cost of providing centering & fabrication of reinforcement which shall be measured and paid under seperate items) including curing, complying with standard speifications as directed by the Departmental Engineer using sulphate resistant cement.
1131Providing and laying base concrete in foundation using Plain Cement Concrete 1:3:6 As base course (40 mm) including consolidation and levelling etc as per standard specifications
1132Supplying & erecting centering for sides & walls ofchamber including supports & strutting for plain surfaces with all cross bracings using 25 mm thick boards suitable purloined over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90 cm centre to centre & supported by casuarinas props 10 cm to 13 cm dia..meter spaced at about 75 cm centre to centre etc. complete complying with standard specifications. Centering for RCC works below GL (wall).
1133Supplying, fabricating & placing in position MS or deformed steel bars for all RCC items of work including cost of steel transporting, straightening, cutting, bending, cranking, binding etc. including cost of binding wire charids, laps to fix the reinforcement in all positions, all labour & materials complete complying with standard specifications & drawings as directed by the Departmental Engineer.
1134Refilling the trenches with suitable excavated earth available along the alignment after the pipes & specials are laid, jointed & tested in layers & watering, ramming & consolidation directed by the Engineer-in-Charge.
1135Colour washing the plastered walls and ceiling with approved colour over the white washed area with neat finishing of 2 coats etc, complying with standard specification and as directed by the Departmental Engineer etc, complete (Inside & outside) - same as white washing
1136Forming Embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick, watering ramming/rolling and finishing to required size, shape, etc. N exc. 1.5m high from base. Existing surplus excavated soil from work area to be used including all costs for tools, plant, labour, etc. complete

AI Tender Summary

OUR REF NO 34872408
AUTHORITY Government Departments
TENDER VALUE 25.80 Crore
LAST DATE 25-11-2022
Authority
Authority Name Directorate General Defence Estates
Work Description Providing Sewer Network, Constructing, Erecting And Commissioning Of Intermediate Sewage Pumping Stations, Lifting Stations And Design Constructions Of Sewage Treatment Plant Of 2 Mld Capacity Based On Sbr Technology And Tertiary Treatment Plant Of 2
Basic Detail
Tender No WCB/034/2022
Bidding Type Tender
Location
City wellington
State Tamil Nadu
Key Dates
Publish Date 18 Nov 2022
Submission Date 25 Nov 2022
Open Date 26 Nov 2022
Finance
Tender Value 25.80 Crore
Tender Fee 26000
EMD 25.80 Lakhs
Exemption Not Available
Document List
2d3173a7-aa8d-4881-b1b9-0e7643aa2429.html
BOQ_631453.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 26, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2d3173a7-aa8d-4881-b1b9-0e7643aa2429.html

xls

BOQ_631453.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender