Tripura State Electricity Corporation Limited-TSECL has published Tender For Design, Supply, Installation, Integration, Operation And Maintenance Of Prepaid Smart Metering System Of 150,000 Smart Meters In Tripura Package Iv. Submission Date for this Tender is 03-02-2023. Energy Meter Tenders in agartala Tripura. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Nov-2022 | Corrigendum | Date | 30-12-2022 |
2 | 05-Dec-2022 | Notice | Other | 30-12-2022 |
3 | 14-Dec-2022 | Corrigendum1 | Date | 13-01-2023 |
4 | 28-Dec-2022 | Corrigendum | Technical Bid | 13-01-2023 |
5 | 10-Jan-2023 | Corrigendumtime | Date | 24-01-2023 |
6 | 21-Jan-2023 | Date Extension | Date | 03-02-2023 |
7 | 24-Jan-2023 | Additional Clarification | Technical Bid | 03-02-2023 |
Sl. No. | Item Description |
1 | Smart Meters and Accessories |
2 | Single phase smart meter, accuracy class 1.0, with net-metering facility complete with all accessories, software and warranty as specified. (excluding communication module) |
3 | Three phase smart meter, accuracy class 1.0, with net-metering facility complete with all accessories, softwareand warranty as specified. (excluding communication module) |
4 | Pluggable Communication Modulefor single / three phase smart meters : RF-Mesh communication |
5 | Pluggable Communication Module for single / three phase smart meters : Cellular GPRS/3G/4G/NB-IOT communication |
6 | Meter box for single phase smart energy meter (IP-55) including all accessories and warranty as specified. |
7 | Meter box forthreephase smartenergy meter (IP-55) including all accessories and warranty as specified. |
8 | Poly-carbonate security seals with steel sealing wire |
9 | Consumer Service Connection (Replacement) |
10 | 1.1 kV 2Cx6 sqmm Al/ XLPE/PVC twin service cable with PVC outer sheath color coding as agreed with TSECL. |
11 | 1.1 kV 4Cx10 sqmm Al/ PVC/PVC service cable with PVC outer sheath color coding as agreed with TSECL. |
12 | Polycarbonatebase board, 8 mm for mounting meter box and fuse cutouts (compatible size for replacements of unusable existing consumer meter boards) |
13 | Al Line Tap / PG Clamp, Double Bolt, Main : 25-50 sqmm / Tap : 4-16 sqmm for connection of service cables to bare conductor LT lines. |
14 | PVC Electrical Conduit, 20 mm, light grey/white colour |
15 | GI wire SWG # 10 (for single phase services) |
16 | GI wire SWG # 8 (for three phase services) |
17 | Distribution Transformer Metering and Replacement ofBulk Consumer Meters |
18 | LTStatic CT operated Smart Energy Meter with net-metering facility, 3x240V,-/5A; 3P4WAccuracy Class 0.5S with communication module (Cellular / RF-Mesh communication as required) including all accessories, software and warranty as specified . |
19 | HT Static CT PT Operated Smart Energy Meter with net-metering facility, 110V,-/5A; 3P4W , Accuracy Class 0.5s with communication module (Cellular communication) including all accessories, software and warranty as specified . |
20 | Test Terminal Block for HT / LT Static Smart Energy Meters, 3P4W including all accessories |
21 | 0.6/1 kV, Cu/PVC/PVC 12C+E x 2.5 sqmm Control Cable |
22 | LT Current Transformer, 50/5 A, Accuracy Class 0.5including all accessories and warranty as specified. |
23 | LT Current Transformer, 100/5 A, Accuracy Class 0.5including all accessories and warranty as specified. |
24 | LT Current Transformer, 150/5 A, Accuracy Class 0.5including all accessories and warranty as specified. |
25 | LT Current Transformer, 400/5 A, Accuracy Class 0.5including all accessories and warranty as specified. |
26 | LT Current Transformer, 600/5 A, Accuracy Class 0.5including all accessories and warranty as specified. |
27 | LT Current Transformer, 800/5 A, Accuracy Class 0.5including all accessories and warranty as specified. |
28 | LT Current Transformer, 1000/5 A, Accuracy Class 0.5including all accessories and warranty as specified. |
29 | Feeder Pillar with CT Metering Compartment, Type FP1, For DTR : 25-100 KVA with NH Fuse Disconnectors 1x400 A + 3x160 A including supply of additional set offuse links (spare) for each NH Fuse Disconnector |
30 | Feeder Pillar with CT Metering Compartment, Type FP2, For DTR : 100-315 KVA with NH Fuse Disconnectors 1x630 A + 3x250 A including supply of additional set offuse links (spare) for each NH Fuse Disconnector |
31 | Feeder Pillar with CT Metering Compartment, Type FP3, For DTR : 400 - 630 KVA with NH Fuse Disconnectors 1x1000 A + 3x315 A including supply of additional set offuse links (spare) for each NH Fuse Disconnector |
32 | HT Meter Box, IP55 or higher,suitable for housing HT-CT Smart Meter and test terminal blocks |
33 | DT Cable, 1.1 kV 1Cx95 sqmm, Al/XLPE/PVC (DTR to FP Incomer) |
34 | DT Cable, 1.1 kV 1Cx240 sqmm, Al/XLPE/PVC (DTR to FP Incomer) |
35 | DT Cable, 1.1 kV 1Cx630 sqmm, Al/XLPE/PVC (DTR to FP Incomer) |
36 | Fdr Cable,1.1 kV 1Cx50 sqmm, Al/XLPE/PVC (FP to Line) |
37 | Fdr Cable,1.1 kV 1Cx120 sqmm, Al/XLPE/PVC (FP to Line) |
38 | Fdr Cable,1.1 kV 1Cx240 sqmm, Al/XLPE/PVC (FP to Line) |
39 | Al Line Tap / PG Clamp, Double Bolt, 50 - 240 sqmm / 25 - 80 sqmm for connection of feeder cables to bare conductor LT lines. |
40 | Communication Networks |
41 | Data Concentrator Unit (DCU)forRF-Mesh NAN networks with GPRS/3G/4G/NB-IOT or Fiber Optic WAN connectivity including all accessories, software and warranty as specified(including spare DTUs) |
42 | Additional Communication Devices : Router/Repeater for resolving line of sight issues in RF mesh networks (provision) |
43 | Enclosure for DCU, IP65, with power supply & MCB with pole mounting arrangement |
44 | Supply of Hardware, Software and other equipment for NOMC (Network Operation & Monitoring Centre) |
45 | Supply of hardware and accessories for establishment of NOMC as specified including centralized management console and workstations, networking equipment, internet router, firewall and intrusion protection system, video display system, printers, online UPS, internet connection, cabling and inventory of critical hardware for spares. |
46 | Supply ofsoftware with licensing for establishment of NOMC including operating systems, DBMS and support software including compilers,display management, network utilities, report generation, diagnostics and backup utilities |
47 | Supply of other required accessories for NOMC as specified including equipment stands, racks, enclosures, additional wiring / devices for modifications to electricity distribution system and furniture for workstations. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail